Statement of Work - Attachment 2 - Architectural Compatibility Plan.pdf

PDF 20 MB Posted

Attached to
Joint Base Charleston (JB CHS) Multiple Award Construction Contract (MACC) Federal contract opportunity
Solicitation number
FA441822R0019
Issued by
Department of the Air Force Air Mobility Command

View the file

Other files for this federal contract opportunity

Other files attached to Joint Base Charleston (JB CHS) Multiple Award Construction Contract (MACC), newest first.
File Type Posted
Solicitation Amendment 01 - Attachment 6 - Berkeley County WD SC20210022.pdf PDF
Solicitation Amendment 01 - Attachment 10 - Wayne County WD NC20220041.pdf PDF
Solicitation Amendment 01 - Attachment 3 - As Built Drawings B63.pdf PDF
Solicitation Amendment 01 - Attachment 5 - Solicitation Section B - Seed Project - 08 Nov 22.pdf PDF
Solicitation Amendment 01 - Attachment 7 - Charleston County WD SC20220023.pdf PDF
Solicitation Amendment 01 - Attachment 2 - As Built Drawings B61.pdf PDF
Solicitation Amendment 01 - Attachment 8 - Dorchester WD SC20220024.pdf PDF
Solicitation Amendment 01 - Attachment 1 - Addendum 01 - Repair Aircraft MX Facility B63 Revised Drawing Sheets.pdf PDF
Solicitation Amendment 01 - Attachment 4 - Addendum 01 SOW - 08 Nov 22.pdf PDF
Solicitation Amendment 01 - Attachment 9 - Orangeburg County WD SC20220016.pdf PDF
JB CHS MACC - Questions and Answers - 09 Nov 22.pdf PDF
Update 1 - JB CHS MACC - Pre-Proposal Conference Slides.pdf PDF
Update 2 - JB CHS MACC - Sign-In Sheet for Attendees.pdf PDF
Amendment 1 - JB CHS MACC - Pre-Proposal Conference Slides.pptx PPTX presentation
Solicitation Attachment YT Seed Project Drawings -Updated.pdf PDF
Solicitation - FA441822R0019.pdf PDF
Solicitation Attachment XY - On and Off-Ramp Procedures.pdf PDF
Solicitation Attachment YV Seed Project Fire Pump Curves.pdf PDF
Statement of Work - Attachment 6 - 01 32 00 - Attachment A - Schedule and Pay Request Calendar Example 1.pdf PDF
Statement of Work - Attachment 10 - 01 33 00 - Attachment B - JB CHS RFI Form.pdf PDF
Statement of Work - Attachment 11 - 01 33 00 - Attachment C - Form 4288-R (Submittal Register).xlsx XLSX spreadsheet
Statement of Work - Attachment 17 - 01 78 00 - Closeout Requirements.docx DOCX document
Solicitation Attachment XW - JB Charleston MACC Work Load Estimate.pdf PDF
Statement of Work - Attachment 1 - JB Charleston Statement of Work for Architect_Engineering (A_E) Services.pdf PDF
Statement of Work - Attachment 3 - 01 11 00 - Summary of Work.docx DOCX document
Statement of Work - Attachment 8 - 01 32 00 - Project Schedule.docx DOCX document
Statement of Work - Attachment 11 - 01 33 00 - Attachment C - Form 4288-R (Submittal Register).pdf PDF
Statement of Work - Attachment 12 - 01 33 00 - Attachment D - Form 4289-R (RFI Register).xlsx XLSX spreadsheet
Statement of Work - Attachment 13 - 01 33 00 - Submittal Procedures.docx DOCX document
Statement of Work - Attachment 14 - 01 35 26 - Attachment A - Accident Investigation Form (CIRS).pdf PDF
Statement of Work - Attachment 15 - 01 35 26 - Governmental Safety Requirements.docx DOCX document
Statement of Work - Attachment 16 - 01 45 00 - Quality Control.docx DOCX document
Solicitation Attachment XZ - Past Performance Project List.xlsx XLSX spreadsheet
Solicitation Attachment YU Seed Project Hydraulics.pdf PDF
Solicitation Section B - JB CHS MACC - Seed.pdf PDF
Statement of Work - Attachment 5 - 01 30 00 - Administrative Requirements.docx DOCX document
Statement of Work - Attachment 7 - 01 32 00 - Attachment A - Schedule and Pay Request Calendar Example 2.xlsx XLSX spreadsheet
Statement of Work - Attachment 12 - 01 33 00 - Attachment D - Form 4289-R (RFI Register).pdf PDF
Solicitation Attachment XX - TOPR - Seed Project - B63.pdf PDF
Solicitation Attachment XT - JB Charleston - Question and Answer Form.xlsx XLSX spreadsheet
Solicitation Attachment XU - Past Performance Customer Questionnaire.pdf PDF
Solicitation Attachment XV - Past Performance Survey.pdf PDF
Solicitation Attachment XX - TOPR - Seed Project - B63.xlsx XLSX spreadsheet
Solicitation Attachment YS Seed Project Specifications.pdf PDF
Solicitation Attachment YT Seed Project Drawings.pdf PDF
Statement of Work - JB CHS MACC.pdf PDF
Statement of Work - Attachment 4 - 01 14 00 - Work Restrictions.docx DOCX document
Statement of Work - Attachment 9 - 01 33 00 - Attachment A - JB CHS Transmittal Form 4025.pdf PDF
Show all 48

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Joint Base charleston architectural compatibility plan

Vision

An Architecture of Community is the long-range vision for Joint Base Charleston.

This is a vision of excellence displayed in a high-quality corporate image for facilities, the landscape, and the environment. It is founded on an understanding and respect for the local architectural character and creating compatible, responsive designs.

Architectural compatibility and Community can be achieved by understanding the vision for Joint Base Charleston and by implementing a design vocabulary. Success-ful examples of high quality facilities, landscaping, and streetscapes that exist at the base and at other military installations are presented in this Architectural Compatibility Plan (ACP). These examples depict the new design standards that will bring about compatibility and achieve the vision of excellence.

table of contents 1 table of contents

Introduction

Joint Base Charleston Design Standards

General Site Standards

General Commercial Building Design Standards

General Industrial Building Standards

General Residential Building Design Standards

Air Base District Map

Air Base Specific Design Standards

Air Base Basewide District

Flightline / Industrial District

Weapons Station Specific Design Standards

Weapons Station District Map

East & West Side Districts

South Annex District

North Side & Waterfront Districts

Ordnance District

Marrington District

Weapons Station Overlay District Map

Nuclear Training & Medical Overlay

Reserves & Training Overlay

Brig Overlay

Implementation

Appendices

Materials and Colors ........................................................................ A1

Exterior Paint .................................................................................. A2

Landscape Materials ....................................................................... A3

Architectural Compatibility Review Board Project Checklist ................ A5

Index ...............................................................................................A7 architectural compatibility plan - Joint Base Charleston2

The Architectural Compatibility Plan (ACP) defines a clear design vocabulary to be used throughout JBC, providing specific standards to be observed in all aspects of exterior design. Compatible architecture is accomplished with buildings that are similar, but also through the use of common design forms, details, materials, site features, and streetscapes.

Quality and compatibility are achieved through creating a unified visual envi-ronment that is based on an Architecture of Community, similar to a campus or small town. The principal design goal is to direct development at Joint Base Charleston toward a livable, attractive, and cohesive installation.

The ACP provides the design standards that will help to build compatible fa-cilities and a quality environment. Implementation of the standards will result in the creation of community.

introduction

Purpose

The purpose of the ACP is to define design standards for buildings, site development, and streetscapes that serve to integrate the visual character throughout the base.

The ACP will help ensure consistent quality design decisions by commanders, plan-ners, architects, engineers, maintenance staff, and residents. It promotes clear, concise communication between Joint Base Charleston as the client and design professionals.

This plan applies to self-help initiatives, small projects, and operations and mainte-nance activities as well as large construc-tion efforts.

The ACP is referenced from and supports the Joint Base Charleston Master Plan and Supplements.

tation section defines methods to facilitate the coordination and approval of design submittals.

Finally, the Appendices provide additional information including an index; a list of building materials, site amenities, paint col-ors, and landscape materials; and check-lists for the ACRB and project personnel.

Follow the established standards found in this section except on building additions or alteration projects where existing mate-rial palettes should be preserved. Use the Appendices in conjunction with the general text of the ACP as a quick reference to spe-cific materials and color specifications.

How to Use This Plan

The ACP defines general and specific de-sign standards for any site and all buildings.

The ACP is then broken up into the main two geographic areas of Joint Base Charles-ton--the Air Base and the Weapons Station.

Each of the geographic areas has specific guidelines in order to more closely tie them together creating a unified campus setting.

However, each area has sub-regions with specific guidelines relating to function or existing conditions.

The Implementation section of the ACP out-lines key elements to ensure success in de-signing and constructing excellent facilities.

It discusses the traditional design process, highlights the importance of site analysis, and describes the role of the Architectural Compatibility Review Board (ACRB), or the designated review authority. The implemen-introduction 3

What is Joint Base Charleston?

Joint Base Charleston is a United States military facility located in the South Carolina cities of North Charleston, Hanahan and Goose Creek. The facility is under the jurisdiction of the United States Air Force 628th Air Base Wing, Air Mobility Command. The facility is an amalgamation of the United States Air Force Charleston Air Force Base and the United States Navy Naval Support Activity Charleston which were merged on 1 October 2010.

Joint Base Charleston was established in accordance with congressional legislation implementing the recommendations of the 2005 Base Realignment and Closure Commission. The legislation ordered the consolidation of facilities which were adjoining, but separate military installations, into a single joint base – one of 12 joint bases formed in the United States as a result of the law. The Joint Base Charleston area encompasses more than 20,000 active-duty, reserve and civilian personnel, spanning across its Air Base and Weapons Station.

Weapons Station

Air Base architectural compatibility plan -Joint Base Charleston4

Joint Base Charleston design standards

Design standards for site, buildings and supporting elements are outlined in this section. These standards encourage architectural compatibility through the use of common forms, materials, colors, and architectural details. These are meant to provide guiding principles for all new construction.

The first priority is to achieve architectural compatibility for Joint Base Charleston as a whole. The second priority is compatibility within an architectural setting or sub-area. Outstanding designs for individual buildings or facilities are the third priority. The goal is to design excellent facilities that satisfy all of these priorities.

Additional standards are broken up into the two main areas of JBC: The Air Base and Weapons Station. These areas are further defined into districts and overlay zones. After reviewing the general standards, see the appropriate section for more specific requirements.

All site and building designs shall meet the most current UFC/DOD Anti Terrorism- Force Protection Criteria.

JBC design standards- site 5 roads

Develop the transportation network to provide a common experience throughout the base that is clean, crisp, neat, and orderly. An organized system of primary, secondary, and tertiary arteries must provide sequential order with each hierarchy of roadway being designed consistently.

Primary n Primary roadways are the widest and fastest arterials and will often contain two lanes of traffic in each direction.

n Minimize stops and turns, and eliminate on-street parking.

n Individual curb cuts are discouraged.

n Keep adjacent on-street parking, parking areas, and buildings away from the road edge.

Secondary n Secondary roadways are feeder streets from access roads to primary roads.

n On-street parking is discouraged.

n Keep adjacent on-street parking and park-ing areas away from the road edge.

n Minimize the number of curb cuts from driveways and area entrances.

Tertiary n Tertiary roadways are the narrowest and slowest public streets and provide access to individual sites or parking areas.

n On-street parking and curb-cuts for drive-ways, parking lot entrances, and service drive entrances are allowed. All curb-cuts should intersect roads at or nearly at right angles.

Service Drives n Maintain a minimum 10-foot setback between the building and service drive.

n Minimize the visual impact of service drives through correct placement of drives and landscape screening.

Paving n Provide asphalt for most roadways.

n Provide concrete paving in loading areas and sites used by heavy vehicles.

n Use gravel for patrol and outlying roads.

Curb and Gutter n Provide 6-inch concrete curbs and gutters for all roads and drives in built-up areas.

n For patrol roads and service drives in outlying areas curbs and gutters may not be required.

general site standards parking

Develop functional lots with clear circulation and a positive appearance that complements the facility. Provide a pleasant transition from the parking area to the facility.

General n Reduce oversized parking areas with landscaped islands and planting strips.

n Use smaller-scale, well-screened lots to minimize the visual impact of parking.

n Parking layout must address main-tenance issues including safety and landscaping.

architectural compatibility plan - Joint Base Charleston 6 n Provide planting medians for every 4 rows of vehicles and planting islands for every 20 stalls.

n Avoid parking on roads, within 30 feet on the approach leg to any controlled intersection or within the needed sight triangle of intersecting roads.

n Use the 90-degree parking configura-tion when possible.

n Coordinate layout for light poles with the islands.

n Use the minimum number of light poles to provide the required illumina-tion.

Setbacks n Maintain a 20-foot setback from streets where possible.

n Provide entrances with sufficient throat lengths to provide adequate queuing storage and permit safe maneuvering.

Reserved Parking n Avoid designating parking spaces by name, rank, or title.

n Where required, use curb mounted signs.

n Consolidate reserved parking into sections instead of having individual spaces.

Paving n Provide asphalt paving as the standard.

n Use concrete where required for heavy vehicles, motorcycle parking, and where fuel spills may occur.

Curb and Gutter n Use concrete curbs and gutters for parking areas. Asphalt curbs, wood timbers, and precast wheel stops are prohibited.

n Unless directed otherwise, do not paint concrete curbs.

walkways and paTHs

Develop a consistent pedestrian circulation system of walkways and paths to enhance the community environment. Connect bus shelters, outdoor plazas, parks, and other pedestrian gathering sites into the overall circulation network.

Paving n Highlight special-use locations, such as plazas, building entrances, and important intersections, with brick pav-ing using Hill Boulevard as an attractive example.

n Provide broom-finished concrete walks in all developed areas.

n Use an asphalt or crushed-fine surface for jogging and bike paths.

n Do not use stamped concrete paving.

n The width of sidewalks, walkways, and paths should reflect the scale of the adjoining features and accommodate the anticipated flow, density and mix of pedestrian traffic.

Walkway and Path Layout n Provide grassed/landscaped buffers be-tween sidewalks and parallel roadways where conditions permit.

n Design curvilinear paths in recreational areas, dorms, housing, and open areas.

n Use straight walkways in formal and other developed sites.

Ramps and Crosswalks n Construct concrete curb ramps with a parallel tooled joint pattern.

n Use flared curb ramps.

n Use reflective paint, white striping, or brick paving at crosswalks.

n Use brick or concrete paving that matches Charleston brick at important circulation nodes.

Plazas and Courtyard Paving n Use brick or concrete pavers as a unifying theme for plazas and courtyard paving.

n Use concrete or brick pavers for band-ing edges and highlights within the design.

n Unless otherwise directed, use a basket weave pattern for pavers.

JBC design standards- site 7 architectural compatibility plan - Joint Base Charleston8 landscaping

Use consistent landscaping to unify the base and enhance the appearance of indi-vidual facilities. JBC should be organized by exterior spaces with these spaces being a shared focus with the architecture. Hill Boulevard at the Air Base is a successful example of a central organizing landscape feature that connects and unifies the facili-ties along its edges.

Maintenance n Select low maintenance native, drought-resistant plant materials that do not require permanent irrigation sys-tems. See page A3 for a list of approved plant materials.

n Allow shrubs to mass naturally and avoid ornamental pruning.

n Use ground fabrics with pine straw mulch to increase moisture retention and control weed growth.

n Irrigation systems should only be used in high-visibility areas. Temporary irri-gation systems can be used to establish new beds.

Formal Landscaping n Use formal plantings along all primary roads, entrance gates, and high-visibili-ty sites.

n Create formal planting by regular spac-ing and symmetrical layout.

n Use large trees to form a canopy along primary roads and that reinforce the scale of the roadway.

n Provide accent plantings at main intersections to enhance the circula-tion network without blocking lines of sight. Consistent recurring plantings contribute to the base’s identity.

Informal Planting n Use mixed species in an informal plant-ing style for community facilities and residential settings.

n Design randomly spaced plantings and tree massing.

n Reinforce pedestrian routes with infor-mal landscaping to add user appeal.

Ground Cover n Use turf in heavily used pedestrian areas, such as recreation fields, parade grounds, and formal lawns.

n Use ground covers and the approved grass seed mix as alternatives to turf in sites where maintenance is difficult.

Edging n Provide metal edging at planting beds as the standard.

n Separate and define all planting areas from sod areas with edging.

n Use brick edging in the most visible and important locations.

n Raised planting beds constructed of brick or split face block may be used but limited to the most visible and important pedestrian areas.

n Wood timber edging is not allowed.

JBC design standards - site 9 screens and enclosures

Screens and enclosures help to minimize the visual impact of undesirable features and provide separation and security where necessary. Both architectural and landscape screens – separately and in com-bination – can be applied to achieve visual continuity throughout the base.

General n Locate utility components in the least visible area with adequate access to minimize the need for screening and enclosures.

n Ensure screens are high enough to conceal equipment, vending machines, and utilities.

Landscape Screens n Reduce the negative visual impacts of parking areas and other unsightly features with landscape screening.

n Where possible, use landscaping instead of walls for screening.

n Use a three-tier landscaped screen that combines ground covers, shrubs, and small trees.

n Use shrubs and landscaped berms to soften the impact of parking areas.

Walls n Use brick with a precast cap when adja-cent to or within 30 feet of a building.

n Articulate walls using recessed sections for planting.

n Use ornamental ironwork inserts in formal settings.

n Use brick columns and metal panels only when remote from a building.

n Use walls to screen utility equipment. If adjacent to a structure, coordinate with the facility’s wall material and color.

n Use trellises and landscaping to soften walls whenever possible.

Dumpster Enclosures n Use brick with a precast cap for wall construction.

n Locate dumpsters to minimize visual impact.

n For new facilities, construct enclosures as part of the building service area.

n Design enclosures to include planting areas and pedestrian access.

n Gates for dumpster enclosures shall be dark bronze.

n Provide concrete pads and concrete access pads in front of enclosure doors.

n Provide bollards to protect the enclo-sure during dumpster servicing activity.

n Use landscaping to minimize impact.

Fencing n Use decorative metal fencing for high visibility sites including CDCs.

n Ornamental railing on walls and fences shall be dark bronze.

n Vinyl-clad chain link fencing in indus-trial areas shall be dark bronze.

n Perimeter fencing shall respond to the site context. Use decorative metal and brick.

architectural compatibility plan - Joint Base Charleston10 siTe FurnisHings

The common use and style of site ameni-ties will further unify the base, providing a “thread of continuity” throughout. Regard-less of where site furnishings are placed on base, the colors and styles should reflect the basewide standard.

General n Select site furnishings from the list on page A1.

n Use metal benches and furnishings with a factory applied powder-coat fin-ish.

n All metal benches and site furnishings shall be dark bronze.

Seating n Provide seating along walkways, near building entries, and in courtyards and plazas.

n Always place benches within a paved area.

n Limit tables to outdoor picnic or dining areas.

Litter / Ash Receptacles n Place surface-mounted or portable litter and ash receptacles at building entrances, pathways, outdoor seating, and picnic areas.

n Locate these to be functional, yet visu-ally unobtrusive.

Freestanding Planters n Minimize the use of freestanding plant-ers.

n When used, locate planters in conjunc-tion with other exterior elements.

n Use surface-mounted planters that match ash and litter receptacles in design.

Bike Racks n Place bike racks in accessible loca-tions along established bike routes and nearby secondary building entrances.

n Use a bollard-style bike rack that can accommodate a minimum of two bicycles.

n Align bollards at sites having multiple racks.

Barbecue Grills n Limit built-in barbecue grills to rec-reational areas, dormitories, and fire stations.

n Use materials that complement adja-cent facilities.

n Locate pedestal-mounted grills near pavilions, parks, and recreation areas for convenience and greater use.

JBC design standards - site 11

Drinking Fountains n Limit exterior drinking fountains to high-use recreation areas.

n Use a vandal-resistant, winterized, surface-mounted, handicapped-accessi-ble metal fountain.

Tree Grates n Use tree grates at all formal plazas and courtyards.

n Provide cast iron tree grates set into concrete paving. Accent grates with brick pavers.

n Tree grates shall be painted Black.

Playground Equipment n Locate play equipment at recreational areas, family housing areas, child devel-opment centers, and youth centers.

n Provide color coded signs to indicate appropriate age group: Red for age 2-5 and Blue for age 6-1 n Incorporate landscaping to provide shade and seasonal color.

n Provide appropriately safe play sur-faces, such as rubber fiber tiles.

n Provide adjacent shaded seating for supervision and avoid conflict with pedestrian traffic.

n Use a consistent style throughout the base.

n Ensure required safety/fall protection zones are established around each piece of equipment.

n Plant materials adjacent to playground equipment need to be carefully selected to ensure they are non-toxic/child-friendly.

Flag Poles n Use a brushed aluminum pole, mount-ed on a concrete base.

n Create a sense of place at flag pole lo-cations with landscape or plaza design.

Picnic Tables n Use prefinished metal picnic tables at all pavilions and recreation areas.

n Group tables to allow for large parties or individual family outings.

Bollards n Use an 8-inch diameter aluminum, domed top bollard as the base stan-dard.

n All bollards in high-visibility areas shall be dark bronze anodized aluminum.

n Comply with ATFP standards for force protection.

n Use similarly designed lighted bollards to enhance pedestrian areas, pathways, and building entrances.

n For bollards protecting against vehicle damage to facility equipment, paint dark bronze with reflective tape.

architectural compatibility plan - Joint Base Charleston 12 ligHTing and uTiliTies

Exterior lighting is a system that has direct and indirect impacts on the visual quali-ties of the base. During the day the fixture and poles are visible. At night the light becomes dominant to signify safety and se-curity and to enhance the visual character of the base. The use of consistent lighting components and the removal of overhead utilities will help to unify the base appear-ance.

Lamp Types n Lamp types to be selected to meet aesthetic, security, safety and energy efficiency requirements.

n Determine wattage, spacing, and height based on individual photometrics of each application.

Luminaires n Square factory finished dark bronze, shoebox-type luminaires are the stan-dard.

n Incorporate recessed, wall-mounted luminaires to wash light across plaza paving and stairs.

n Uplight significant landscaping and ar-chitectural features to emphasize their importance. A 12- by 8-inch concealed, rectangular well light is preferred.

n Minimize the use of building-mounted fixtures for general illumination of service yards and outdoor spaces.

Light Poles n Use square light poles..

n Provide precast concrete or factory fin-ished, dark bronze, aluminum or steel light poles as basewide standard.

Mounting Heights n Control spillover light near residential areas.

n Keep mounting heights low. Any lights mounted over 30 feet high require spe-cial review.

Utility Lines and Structures n Place utilities underground and screen above-ground equipment to minimize their visual impact.

n Exposed conduits, cables, and wires are prohibited.

n Construct underground utility system components as elements of any new or rehabilitated facilities. When this is unfeasible, locate screened equipment on the least visible side of the building.

Fire Hydrants n Locate fire hydrants at least 5 feet away from other structures. Maintain a 30-inch clear area around the hydrant.

n On Air Base paint hydrants dark brown with color-coded caps to indicate pres-sure.

n On Weapons Station paint hydrants yellow with color-coded caps to indicate pressure.

JBC design standards - site 13

Painting Utility Components n Locate freestanding pipes, above-ground utility system components, and outdoor electrical equipment (ground-mounted transformers, pad-mounted switch gear, sectionalizing terminals, etc.) to minimize their visual impact on the surroundings.

n When located adjacent to facilities, paint components so they integrate with the adjacent surfaces.

signage

Signs are an important and positive ele-ment in the overall base appearance. Their purpose is to clearly communicate neces-sary or helpful information for directions, identification, and customer service without adding visual clutter.

General n Use signs of high quality design and construction to present a professional image.

n Minimize the number of signs on base to eliminate visual clutter resulting from over use of signage.

n Identify each decision point with a sign that clearly indicates the options.

n Keep names of destinations consistent throughout the system, including the names on the maps and the names used by security police when directing visitors to the base.

n Do not omit a destination from a series of direction signs until that destination is reached.

n Keep building-mounted regulatory signs to the minimum number and size required to meet safety regulations

JBC Master Plans Supplements n Refer to the JBCHS-Weapons Signage Guide for all signage specifics.

architectural compatibility plan - Joint Base Charleston14

JBC design standards -commerical 15

The following design standards are applicable to the entire installation, to both host and tenant organizations. They are based on the existing archi-tecture and encourage contemporary adaptations of the vernacular.

Site planning and site development issues contribute significantly to the architectural con-text. Building setbacks and the scale and definition of space are as fundamental to creat-ing architectural compatibility as consistent facade designs. Features such as esplanades, allees, promenades, parkways, plazas, and courtyards create an organizing bond between buildings and the landscape.

Buildings

Achieving compatibility among buildings is essential in creating an Architecture of Community. Develop facilities with a common design theme and character to enhance architectural compatibility. Unity

– as opposed to conformity – is the goal.

Style / Form n Buildings should be elevated above the ground plane with the stair, ramp, and other transition elements expressed as an architectural feature.

n Develop a hierarchy of individual facade components that are expressed visually.

n Emphasize vertical proportions on fa-cades through the use of columns and pilasters.

n Articulate building facades to promote areas of shadows.

Scale n Reduce the monumental appearance of large structures by developing smaller massing components along the ground plane.

n Articulate large roofs with clerestories, monitors, and skylights.

n Recall a human scale in brick facades with water tables, belt courses, sills, lin-tels, friezes, and copings in a contrast-ing material, color, or pattern.

general commercial building design standards architectural compatibility plan - Joint Base Charleston16 wall sysTeMs

Brick n Use standard size face brick in a run-ning bond pattern with tooled concave joints. Header, rowlock, and soldier coursing with corbeling or other ac-cents are encouraged.

n Conceal expansion joints with down-spouts or locate them at transitions in the wall such as at pilasters or reveals.

n Use natural colored Portland cement mortar.

n Efflorescence in masonry work is unac-ceptable. Measures must be provided to prevent it.

Architectural Precast n Detailed designs and patterns may be provided in the castings to create an individual character for a single facility or complex.

Concrete Block n Use standard 8x8x16 split-faced concrete block in a running bond with tooled concave joints. Header coursing may be used as accents.

Stucco n Where stucco is allowed, use a traditional three-coat stucco system.

Scratch and Brown coats should be cement-based mixes with the finish coat being a synthetic-based plaster.

Sand finish is the standard.

Base n A clearly defined articulated building base with a minimum height of 30 inches is preferred for new buildings.

n Distinguish the base from the facade with detailing and / or a change in material.

JBC design standards -commercial 17

Other Materials n Limit the use of prefinished metal wall panels to special applications and large industrial facilities.

n Factory finish all exposed metals with a coating application such as Kynar-500.

n Generally, match existing wood, split-faced block, stucco, and other permanent materials only in alteration projects.

n Do not use an Exterior Insulation Finish System (EIFS). A synthetic hard-coat may be used over the scratch and brown coats for the final finish.

n Glass block is an acceptable material for limited use in building facades with ACRB approval. Comply with ATFP requirements.

Wall Components n Integrate all mechanical, electrical, lighting, and other building compo-nents including downspouts into the overall architectural design.

n Utility components, such as speakers, cameras, and antennas should have their location clearly defined as part of the building design.

n Exposed conduits, cables, and piping on exterior walls are prohibited.

n All gas meters, fire bells, vents, louvers, grilles, and electrical and communica-tions boxes shall be Dark Bronze on brick buildings or match the painted wall on which they are mounted.

n Wall-mounted light fixtures must be of decorative designs and part of the facade composition.

Applied and Integral Colors n Joint sealants shall match the color of the darker adjacent surfaces. When ad-jacent surfaces are the same color use a 10% darker joint sealant in the same color.

n Paint freestanding pipes and above-ground utility system components SW 2007 “Nightscape” when in a remote location.

n All outdoor electrical equipment (ground-mounted transformers, pad-mounted switch gear, sectionalizing terminals, etc.) shall be factory finished SW 2007 “Nightscape”.

architectural compatibility plan - Joint Base Charleston18 rooF sysTeMs

Configuration n Use a 5:12 roof slope wherever possible, with a minimum of 3½:12 as the general standard for new construction.

n Steep sloped roofs should have a mini-mum SRS of 29 to reduce heat gain.

n Low sloped roofs should have min SRS of 78 to reduce heat gain.

n Curved roof forms are permissible on a limited basis with approval of the ACRB.

n Do not use low-sloped roofs as the predominant roof form.

n Break up the massing of large struc-tures to allow for sloped roofs to the maximum extent feasible.

n Metal roofing for large industrial build-ings may be of the minimum slope recommended by the roofing manufac-turer.

Material n Use factory-finished, standing seam metal roofing on sloped roofs. A 16-inch wide panel with a 2-inch raised standing seam is the standard.

Parapets / Copings n Sloped parapets with horizontal flanks on the gabled end should be the same slope as the roof.

n Use properly flashed precast concrete copings or painted metal copings on all parapet walls.

n All precast copings should have raked joints filled with elastomeric joint seal-ants.

n Painted metal copings are to be prefin-ished (Kynar 500 or equal) and match roof color.

JBC design standards - commerical 19

Fascias, Gutters, and Downspouts n Incorporate continuous metal fascias.

Coordinate fascia height to the scale of the facility.

n Avoid the use of turn-down standing seam metal fascias.

n When turn-down fascias are used do not use downspouts and gutters.

n Metal copings, gutters, downspouts, scuppers, etc, should match roof color.

n Provide concrete splash blocks or cast iron receivers at grade connected to the storm drainage system.

n Interior roof drains and open scuppers are allowed only with approval of the

ACRB.

Roof Vents and Elements n Minimize, consolidate, and organize roof penetrations.

n Combine roof vents whenever possible and place them on the least visible slope of the building.

n Paint PVC pipes and other roof ele-ments to match the roofing color.

n Do not use rooftop mechanical units unless mandatory; screen them when required.

n Dormers may be developed to house mechanical equipment when they are designed integrally with the building.

Do not place dormers arbitrarily.

n Avoid roof-mounted antennas.

n Mechanical vent sizes and shapes should be consistent with architectural elements.

architectural compatibility plan - Joint Base Charleston20 enTrances

Entrances serve as the transitional element from exterior to interior and provide design opportunities to enhance the facility. The entrance should be the focal point on a facade with its size and architectural detailing used to delineate the relative importance of the building in the community.

General n Define access and the importance of a facility by emphasizing the entryway.

n Align site access so that the building entrance is clearly visible and high-lighted as a prominent feature.

n Develop the scale of entrances to be consistent with the building using the base’s approved materials palette.

n Projected entrance features such as porticos, loggias, or porte-cocheres with gabled roof forms are preferred.

n Create enclosed vestibules as air locks at building entrances.

Primary Entrances n Incorporate landscape planters, and plazas into designs.

n Provide primary entrances with an overhead enclosure for weather pro-tection. Cloth awnings are acceptable with permission of the ACRB.

n Use columns, arches, and other en-trance features as appropriate for the vernacular style.

Secondary Entrances n Reflect the character of the building’s primary entrance at a smaller scale.

n Provide an overhead enclosure for weather protection.

n Provide a small courtyard or seating area near the secondary entrance.

Arcades n Arcade elements may be used as an extension of the building’s entrance.

n Where provided, integrate arcades with the building’s form, materials, and detailing.

Drop-offs and Porte-cocheres n Porte-cocheres should be limited to special, high profile facilities and embellished with ornamental detailing in the architecture and landscaping.

n Construct drop-offs or porte-cocheres as an integral part of the building entrance, compatible with the building materials and detailing.

Handrails n Handrails shall be finished with a powder-coated surface.

n Integrate handrail designs with the facility design.

Service Entrances and Emergency Egress n Provide unobtrusive service entrances near service drives or parking areas.

n Weather protection may be excluded at doors used only for emergency access.

Loading Areas/Docks n Minimize visual impact with proper sit-ing and access.

n Use landscaping and walls to screen and separate loading docks.

JBC design standards - commerical 21

Doors and Frames n Use aluminum storefront systems with thermal-break construction.

n Window and door frames shall be dark bronze.

n Sealants applied adjacent to windows and doors should match the color of the frame.

Glazing n Double-glazed insulating e-glass in solar bronze is the standard.

n Mirrored and plastic glazing shall not be used.

n Use tempered glass for doors and side-lights at entrances.

n Glass block is an acceptable material for limited use in building facades with ACRB approval. Comply with ATFP requirements.

n Translucent fiberglass glazing is accept-able. Comply with ATFP requirements.

Skylights n Develop clerestories or low-profile skylights integrally with the building design.

n Cupolas and monitors may be used on special projects with approval of the

ACRB.

Door Hardware n Select u-shaped door pulls, lever handles, and thin-line panic bars.

n Install wall bumpers and avoid using floor stops.

Security Screens n Electronic security systems are pre-ferred to physical screens or bars.

n Where physical barriers are required, develop simple rectangular designs that are unobtrusive.

Protection from Hurricanes n All windows. doors, storefronts & curtainwalls to be designed to meet the current wind borne debris impact requirements.

n Where approved on small projects, pro-vide permanent stainless steel hooks in walls at windows to accommodate temporary protection boards when required.

n Do not anchor temporary protection boards to exterior walls.

windows and doors

Openings n Punched windows with frames set back from the facade approximately 4 inches are preferred.

n Define the window opening with lintels and sills in a contrasting material, pat-tern, or detail.

n Square-proportioned windows may be used in groupings to complement an overall facade design.

n Use regularly spaced windows to estab-lish contextual rhythms.

n Arched openings may be used to high-light key building features.

n Operable windows are preferred and should have screens.

architectural compatibility plan - Joint Base Charleston 22 ancillary sTrucTures

Promote continuity in outdoor spaces and reduce visual clutter by designing compatible ancillary structures. All out-buildings should be of a consistent design, reflecting the character of the surrounding architecture. They shall follow the design criteria for the particular setting, relying on the context for materials, color, and detailing.

General n Construct pavilions and waiting shelters using the approved district brick, metal roofs, and precast concrete details.

n Coordinate the siting of all ancillary structures with each other and adjacent buildings.

n Integrate the structure with landscap-ing.

n Do not use temporary buildings.

Bus Shelters n Construct new bus shelters with brick walls and standing seam metal roofs in the basewide setting.

n Provide glazing front and back to allow for views and provide wind protection for the user.

n Coordinate the placement of shelters with landscaping and other site ele-ments.

n Integrate shelters into the site by providing proper setbacks allowing for adequate circulation space.

n Use brick paving as an accent material for concrete walks.

Kiosks n Use kiosks to display community flyers for upcoming sales and events.

n Design kiosks with metal roofs, brick, and concrete details compatible with surrounding architecture.

Pavilions n Construct new pavilions with brick piers and hipped standing-seam dark bronze metal roofs at high visibility locations.

n Pre-manufactured pavilions may be used in low-visibility locations only.

n Organize pavilions to create gathering areas with an internal focal point.

n Minimize the number of pavilions in the main base area.

n Centrally locate pavilions between several facilities for multipurpose use.

JBC design standards - site 23

Bike Storage Structures n Bike storage structures should match the materials of the adjacent facility.

n Enclosed bike storage structures are not allowed.

Arbors / Trellises / Pergolas n Use arbors, trellises, and pergolas to integrate landscaping into community seating areas. Incorporate a place for notes and flyers when applicable.

n Design these elements with materials and details that are compatible with the surrounding architecture.

n Arbors, trellises, and pergolas may be used in plazas and near building entrances.

n Incorporate these elements into the building designs when appropriate.

Seating Walls n Incorporate seating walls in plazas, courtyards, and high-use sites.

n Design wall caps and copings to accommodate seating or include free-standing or wall-mounted seating.

n Integrate seating walls with landscap-ing.

Industrial areas contain warehouses, hangars and maintenance facili-ties which give support to the rest of the base. These areas should use simplified industrial detailing for massive buildings. Buildings should be designed with forms, materials, and color palettes similar to those of the General Commer-cial Building Design Guidelines, but with simplified detailing more befitting their function.

general industrial building standards architectural compatibility plan - Joint Base Charleston24 general

Large buildings – common to this area

– require careful design and orientation to avoid unappealing monolithic facades along primary and secondary roads.

Buildings n Lower the apparent height of hangars and warehouses by arranging single-story spaces along the perimeter in high-visibility areas.

n Integrate large masses and volumes with smaller ones to minimize the scale.

n Use openings, changes in material, and architectural detailing to articulate large monolithic walls.

wall sysTeMs n Use brick on all one- and two-story buildings in high-visibility areas.

n Cap brick parapet walls with precast buff-colored concrete coping.

n On larger structures, use flush metal panels above the first level of brick.

n Use metal panels on support facilities in less prominent locations.

n Provide curbs and bollard protection to control vehicular / equipment traffic where necessary.

n Locate visible vents and louvers as planned design elements; avoid random placement.

n Vents and louvers are to match the color of adjacent wall panels on painted structures and should be dark bronze on brick structures.

JBC design standards - industrial 25 n All structures must use hipped or gabled roof forms.

n Brick structures may use sloped para-pet end walls with horizontal flanks.

n Low-slope roofs are allowed only for very large volumes or accent sub-masses.

n Use built-up roofing material where minimal-slope roofs are permitted.

n Screen low-slope roofs with parapet walls.

windows and doors n Use vertically proportioned or ribbon windows, clerestories, and Kal-wall to promote natural lighting and reduce the mass of the facade.

n Windows, doors, and frames must be dark bronze on brick structures.

n Primary entrance doors are to have full glass panels.

n Secondary-use doors, such as service and exit-only doors, shall be painted to match adjacent wall surfaces on painted structures.

landscaping n Reduce the density of landscaping by grouping landscape elements at public areas, such as entries or courtyards.

screens and enclosures n Integrate physical security measures into the architectural design process.

n Use screen walls, raised planters, and defined roadways in selected locations to direct and limit facility access and increase force protection.

n Painting of Jersey barriers is prohibited.

Residential architectural settings should express a neighborhood image that distinguishes them from the remainder of the base. Achieving archi-tectural compatibility relies on the use of consistent building materials, site furnishings, and landscaping.

Residents are encouraged to use the standards creatively to express individual pride of place in and around their homes.

general residential building design standards architectural compatibility plan - Joint Base Charleston26 general

Match existing styles in housing renovation alteration projects.

Construct new community facilities follow-ing the basewide design standards.

wall sysTeMs n Use trim and accent colors that are compatible with the field colors and that highlight significant building features.

n Alternate randomly exterior color schemes using the paint and siding colors specified on page A1.

n Exterior materials should be low main-tenance. Brick, vinyl and cementitious siding are allowed.

ancillary sTrucTures n Install bus shelters at locations conve-nient to the family housing areas.

n Use bus shelters that are sized to ac-commodate the number of people using them.

n Use the base standards for materials and form.

landscaping n Employ informal landscaping to inte-grate new with existing housing areas and to improve the overall community setting.

n Add plantings for shade and privacy and develop foundation plantings.

n Landscape the perimeter edges of recreational areas and common areas.

n Use landscaped berms to soften major

JBC design standards - residential 27 n Use trees to develop a street tree pro-gram.

n A variety of self-help landscape ma-terials are offered to the residents to establish unique personal environments around their home.

screens and enclosures n Use wood fencing for backyard privacy.

Wood is allowed only in the Residential setting.

n Incorporate wood shadow box inserts in fencing and trash enclosures.

n Use vinyl-coated chain link fencing around the base boundary of the hous-ing area.

roads n Enhance streetscapes with landscap-ing, walkways, and site furnishings.

n Use roadway features such as smaller radius corners and narrow street widths to reduce traffic speeds in residential areas.

walkways and paTHs n Emphasize pedestrian and bicycle circulation within housing areas and connect housing to community facili-ties.

n Use concrete pavers to emphasize major crossings.

n Provide landscaping, pedestrian-scale lighting, seating, and other basewide site furnishings along walkways.

n Use concrete or bricks for patio proj-ects.

ligHTing and uTiliTies n Provide pedestrian-scale lighting fix-tures throughout housing areas.

n Provide parking lot and street lighting that matches the basewide standard for primary roads and parking lots.

The Air Base is divided into three distinct architectural districts: Basewide, Flightline / Industrial, and Residential (see the map above).

Joint Base Charleston General Design Standards shall be applied to all projects. When a project is located in the Air Base Basewide or Flightline / Industrial District more specific standards from those sections of the ACP shall be applied. Guidelines for the Residential District are found in the General Residential Design Standards.

Basewide

Flightline/Industrial

Residential architectural compatibility plan - Air Base28 air base specific design guidelines air Base district Map design standards - air base basewide 29 air base basewide district general

New buildings shall conform to these stan-dards to create an overall campus feel to the Joint Base Charleston Air Base wall sysTeMs

Brick n Use brick installed per the General Commercial Guidelines as the promi-nent wall material.

n Use Charleston brick with precast ac-cents in walls combined with sloped roofs and pronounced eaves.

n Brick may be used when appropriate for lintels, sills, arches, or quoins. Detail-ing may be used to emulate bearing wall construction.

Architectural Precast n Precast is appropriate for lintels, sills, water tables, belt courses, and friezes.

Other facade elements made of precast should be used sparingly to ensure that brick remains the prominent material.

The Air Base has a foundation for architectural unity. The existing archi-tecture depicts a predominant materials palette, a consistency of material detailing, and an acute awareness of historical design precedent. The fol-lowing design standards are applicable in addition to the general design standards, to the Air Base Basewide District, to both host and tenant organizations.

They are based on the existing architecture and encourage contemporary adaptations of the vernacular.

architectural compatibility plan - Air Base30

Concrete Block n Use 8x8x16 split-faced concrete block where allowable and install per the General Commercial Guidelines.

Stucco n Stucco is allowable per the General Commercial Guidelines.

Other Materials n Use other materials per the General Commercial Guidelines.

rooF sysTeMs n Hipped roofs are preferred for most buildings. Gabled end walls with sloped parapets and horizontal flanks may also be used. Flat roofs with continuous par-apet walls are discouraged and should be limited to special use facilities.

n Gabled elements are encouraged at entries and to break up large masses.

n Metal roofing should be dark bronze.

n Provide parapet walls with precast cap for low sloped roofs and gable ends.

windows and doors n Windows and doors should follow the General Commercial Guidelines.

screens and enclosures n Provide screening and enclosures per the General Commercial Guidelines.

The flightline encompasses aircraft hangars and maintenance facilities.

This area uses simplified industrial detailing for massive buildings. Build-ings should be designed with forms, materials, and color palettes similar to those of the Air Base Basewide district, but with simplified detailing more befitting their function.

flightline / industrial district general

Follow the JBC General Industrial Design Standards with the additional requirements listed below:

Buildings n Observe all horizontal and vertical safety restrictions along the flightline.

n Lower the apparent height of hangars and warehouses by arranging single-story spaces along the perimeter in high-visibility areas.

wall sysTeMs n Use brick on all one- and two-story buildings in high-visibility areas.

n Flightline security walls should be coordinated with the design of adjacent facilities or the immediate context.

rooF sysTeMs n Low-slope roofs are allowed for very large volumes or accent sub-masses.

n All small structures or small attached areas to larger structures must have a high slope. Use hipped or gabled roof forms for the majority of areas. Curved roof forms are acceptable in a case by case basis.

landscaping n Minimize the use of deciduous trees and shrubs to prevent leaf buildup along the apron and runway.

design standards - air base flightline/industrial 31

The Weapons Station, as laid out in the master plan, is divided into eight distinct districts: West Side, East Side, North Side, Waterfront, South Annex, Housing, Marrington and Ordnance. Additionally, there are several overlay zones that provide specific standards for those areas that do not directly line up with the district boundaries. In addition to these districts and overlays, there is the Short Stay Recreational Area on Lake Moultrie. This remotely located recreational area includes existing cabins, villas, campsites, picnic pavilions and a conference center. The Marrington District should be used as a guide for any new structures or renovations to this area.

General and specific design standards for all buildings are included in the JBC General Site and Building Standards. The more specific standards from the District and Overlay Sections of the ACP shall be applied.

architectural compatibility plan - Weapons Station32 weapons station specific design guidelines

Northside

Ordnance

Marrington

Waterfront

South Annex

East Side

Housing West Side (MENRIV)

Housing

Waterfront

Waterfront

Date

MONTH XXXX

Checked By

XXX

Project No.

Figure

XXXX

Project Location Map Title

KEY

Note(s)

Projection NAD83 SC State Plane Feet

Source(s) Joint Base Charleston GeoBase Office

Ê 0 2,0001,000 Feet

Joint Base Charleston Charleston, SC

Drawn By

XXX

Installation Area

Districts East Side

Housing

Marrington

Northside

Ordnance

South Annex

Waterfront

West Side (MENRIV)

East Side

West Side

North Side

Waterfront

South Annex

Marrington

Ordnance

Housing design standards - weapons station district map 33 weapons station district Map architectural compatibility plan - Weapons Station34 east & west side districts

The East Side & West Side Districts form the Central Core of the JBC Weap-ons Station with Red Bank Road forming the principal artery. The West Side District forms the principal entrance to the Weapons Station consisting of mostly community, support and recreational facilities. The East Side District lies behind the main security gate and consists of mostly administrative and maintenance facilities. A golf course comprises a good portion of this district.

general

New buildings shall conform to these standards so that a cohesive entry corridor is formed.

Buildings n Provide a clearly defined base using a distinct material from the main body.

n Provide gable forms to delineate entry and hierarchy.

n Trellis or porch elements are encour-aged--particularly on south and west facing facades.

wall sysTeMs

Brick n Use brick installed per the General Commercial Guidelines as the promi-nent wall material.

n Charleston brick is the standard (South-ern 355 w/ flash by Richtex).

Architectural Precast n Precast is appropriate per the General Commercial Guidelines.

Concrete Block n Use 8x8x16 split-faced concrete block as a base material…