Solicitation Attachment EXHIBIT E - Past Performance Questionnaire Expand Lab.pdf

PDF 348 KB Posted

Attached to
Y1DA--Amendment 0007 to Expand Laboratory Construction Project 595-667 Lebanon VA, Lebanon, PA. Amendment incorporates RFIs and Specification and Drawing Addendum.
Solicitation number
36C24421R0018
Issued by

About this file

This document is a past performance questionnaire for a contractor submitting a proposal for an expansion of laboratory construction project at a Veterans Affairs medical center in Lebanon, Pennsylvania. The project involves renovating 4,750 square feet of an existing main laboratory and constructing a new 6,900 square foot addition, including exterior construction of a single-story addition and interior construction of floors, walls, ceilings, mechanical and electrical systems. Reference contacts are asked to evaluate the contractor's performance on a scale of 0 to 5 based on quality, timeliness, compliance, safety, and overall customer satisfaction. Specific criteria include management and workmanship, adherence to schedule, business practices, compliance with laws and regulations, and reasonableness of cost proposals. The completed questionnaires must be returned to the contracting officer at the Department of Veterans Affairs network contracting office by a specified due date.

View the file

Other files

File Type Posted
36C24421R0018 0007_1.docx DOCX document
SITE-01.pdf PDF
Section 221100 - Facility Water Distribution.pdf PDF
SITE-02.pdf PDF
Addendum 01 with Attachments to Specifications and Drawings.pdf PDF
RFI document for Amendment 0007.pdf PDF
36C24421R0018 0006_1.docx DOCX document
36C24421R0018 0005_1.docx DOCX document
36C24421R0018 0004_1.docx DOCX document
RFI Questions and Answers.pdf PDF
36C24421R0018 0003.pdf PDF
Pre-proposal Roster of Attendees for 12-14 and 12-30 Visits.pdf PDF
36C24421R0018 0003_1.docx DOCX document
36C24421R0018 0002_1.docx DOCX document
Sign In Roster from Pre-Bid 12-14-2020 595-667- Construct New Lab.pdf PDF
36C24421R0018 0001_1.docx DOCX document
100 Specifications - Full Set.pdf PDF
Solicitation Attachment Specification100 Vol.1.pdf PDF
Solicitation Attachment EXHIBIT B - Subcontractor Information and Consent Form Expand Lab 595-667.pdf PDF
Solicitation Attachment Specification 100 Vol.2.pdf PDF
36C24421R0018_2.docx DOCX document
Solicitation Attachment JA - Fire Alarms Signed.pdf PDF
Solcitation Attachment JA - Security System Signed.pdf PDF
Solicitation Attachment EXHIBIT D -Transmittal Letter for Past Performance Evaluation Questionnaire 595-667 Expand Lab.pdf PDF
Solicitation Attachment EXHIBIT C - Calculation of Self-Performed Expand Lab.pdf PDF
36C24421R0018.pdf PDF
Solicitation Attachment EXHIBIT A - Past Performance Relevancy Questionnaire Expand Lab.pdf PDF
Solcitation Attachment JA - HVAC Controls Signed.pdf PDF
Solicitation Attachment JA - Locksets Signed.pdf PDF
Solcitation Attachment Drawings 595-667 FULL SET.pdf PDF
Solicitation Attachment Wage Determination.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Department of Veterans Affairs Network Contracting Office 4

1010 Delafield Road Pittsburgh, PA 15215

1 | P a g e

Past Performance Questionnaire for: Solicitation Number 36C24420R0084 Expand Laboratory Construction, Project 595-667

INSTRUCTIONS TO OFFEROR

Complete the CONTRACTOR INFORMATION section, below (type answers into light blue shaded boxes). Save the document. Send an electronic or hard copy print of the form to each of your reference contacts, asking them to please complete the form and submit it according to the instructions, below.

Company Name Street Address

Point of Contact (POC) City

POC Phone Number State Reference Project Title Zip Code

Contract Period of Performance (start to finish):

Email

Contract Number Contract Dollar Value

Description of Work Role of Contractor on This Project (check appropriate box)

Prime Contractor Sub-contractor Key Personnel

INSTRUCTIONS TO REFERENCE CONTACT

The contractor named above is submitting a proposal for a United States Department of Veterans Affairs contract, and has sent this form to you as a past performance reference contact. Please complete the following pages in full (all areas shaded in light yellow, below). Once completed, please send the form to the Contracting Officer via postal mail or email directly to:

Department of Veterans Affairs 1010 Delafield Road ATTN: Angelamarie Scott/ 36C24420R0084 Pittsburgh, PA 15215

Email address: Angelamarie.Scott@va.gov

Please return the completed form ASAP, but no later than 1:00 pm local time, If you have any questions, please contact the Contracting Officer: Angelamarie.Scott@va.gov.

mailto:Angelamarie.Scott@va.gov

RESPONDENT INFORMATION [completed by Reference Contact]

Company Name Street Address

POC Name City

Phone Number State

Email Zip Code

PERFORMANCE INFORMATION: Choose the number on the scale of 0 (Neutral) to 5 (Exceptional) that most accurately describes the contractor’s performance or situation. PLEASE PROVIDE AN EXPLANATION FOR THE OVERALL RATING in the Remarks section, below.

0 1 2 3 4 5

NEUTRAL UNACCEPTABLE MARGINAL ACCEPTABLE VERY GOOD OUTSTANDING

No record of past performance, or not applicable or the record is inconclusive.

Performance did not meet most contractual requirements. There were serious problems and the contractor’s corrective actions were ineffective.

Performance did not meet some contractual requirements.

There were problems, some of a serious nature, for which corrective action was only marginally effective.

Performance met most contractual requirements.

There were some minor problems and corrective actions taken by the contractor were satisfactory.

Performance met all contract requirements and exceeded some to the government’s benefit. There were a few minor problems, which the contractor resolved in a timely, effective manner.

Performance exceeded all contract requirements. There were no problems.

The Contractor … 0 1 2 3 4 5

QUALITY – MANAGEMENT & WORKMANSHIP

1. Provided experienced managers and supervisors with the technical and administrative abilities needed to meet contract requirements.

2. Demonstrated ability to hire, maintain, and replace, if necessary, qualified construction personnel during the contract period.

3. Provided and followed approved quality control plan and/or inspection procedures to meet contract requirements.

4. Corrected deficiencies in timely manner and pursuant to their quality control procedures.

5. Submittals clearly identified the proposed item IAW the specifications and drawings.

6. Suggested alternative approaches to problems.

TIMELINESS AND ADHERENCE TO SCHEDULE

7.

Contractor provided timely notices of possible delays/schedule revisions.

REMARKS:

8.

Timeliness in submitting submittals and reports and responding to agency inquiries, RFP's, etc.

9. Developed realistic and met approved progress schedules.

BUSINESS PRACTICES/CUSTOMER RELATIONSHIP AND ABILITY TO PERFORM

10.

Displayed initiative to solve problems.

11.

How well did the contractor work independent of Government guidance, oversight and assistance?

12.

Subcontractors / tradesmen were adequately managed and coordinated. Explain any subcontracting issues (positive or negative) that impacted the performance of your contract(s).

13. For contract changes, contractor provided timely and realistic change order proposals.

COMPLIANCE & SAFETY

14. Reports (i.e., daily, test, logs) / records were submitted completely and accurately satisfy the requirement.

15.

Applicable to Federal Contracts –Contractor complied with applicable Federal Laws and Regulations such as Construction Wage Rate Requirements – timely payrolls and compliance; Drug-Free Workplace; Environmental Regulations and Use of Recovered Materials; Executive Order 13101 Greening the Government.

16.

Contractor’s safety program was in compliance with federal regulations. Contractor implemented and followed their safety plan and ran a “safe jobsite”.

INFECTION CONTROL

17.

Contractor had an Infection Control Process in place and complied with agency Infection Control Requirements.

OVERALL CUSTOMER SATISFACTION

18. Demonstrated reasonableness in modifications cost proposal.

19. Was the contractor ever issued a cure or show cause notice under the referenced contract? If yes, explain outcome in “remarks.”

YES NO

20. Would you award another contract to this contractor? If not, please explain in “remarks.”

YES NO

OVERALL PERFORMANCE RATING:

REMARKS (Please use as much space as is needed – the box will expand as you type).

I hereby certify that the information that I have reported above is accurate to the best of my knowledge.

Printed Name

E-mail address

Business Title Signature Date