Draft_NIST_WWVB_Tower_8_Anchor_Repairs_Drawings_2014-10-20.pdf
PDF 4 MB Posted
- Attached to
- Multiple Award Construction Contract
- Solicitation number
- SB1341-18-RP-0009
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A003.pdf | ||
| Sign-in_Sheet_April_30_Visit.pdf | ||
| A002.pdf | ||
| A001.pdf | ||
| Signin_Sheet.pdf | ||
| Attach_3_NIST_WWVB_Tower_8Anchor_Repair_Specs_2014.09.pdf | ||
| Attach_6_Price_Breakdown.xlsx | XLSX spreadsheet | |
| Attach_5_DBWages.pdf | ||
| Attach_4_NIST_WWVB_Tower_8_Anchor_Repairs_Drawings_2014-10-20.pdf | ||
| 1442_MACC_RFP.pdf | ||
| MACC.PPTX | PPTX presentation | |
| RFP_Attch_A_Construction_Exp_Proj-Data-Sheet.doc | DOC document | |
| Attach_2_Berm_SOW.pdf | ||
| RFP_Attch_B_NIST_AMD_Boulder_PPQ_Form.doc | DOC document | |
| Attach_1_General_Requirements.pdf | ||
| Draft_RFP.pdf | ||
| DRAFT_MACC_SOW.docx | DOCX document | |
| DRAFT_Task_Order_SOW.docx | DOCX document | |
| DRAFT_NIST_WWVB_Tower_8Anchor_Repair_Specs_2014.09.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I
I
I I
I
UTAH I
I I
I I
I
I
WYOMING I NEBRASKA
---,---_J_ ___ _
PROJECT LOCATION
CRAIG STEAMBOAT
-"";;:;',-?------!?SPRINGS
1 40 FT. COLLINS
MEEKER
GRAND
JUNCTION
MONTROSE
RIFLE
STERLING
DENVER 11
COLORADO
SPRINGS 71
LIMON
I __ _ I
I
I l'----1
I
KANSAS
I CORTEZ I
SYMBOL
DURANGO
DESCRIPTION
INTERSTATE HIGHWAY
U.S. HIGHWAY
STATE HIGHWAY
NORTH ARRAY
ANTENNA 2
ALAMOSA
NEW MEXICO
SCALE OF MILES
50 0 50
50 0 50 100
SCALE OF KILOMETERS
LOCATION
NORTH
POUDRE
RESERVOIR
NUMBER 6
MAP
PROJECI' LOCATION
SOUTH ARRAY
ANTENNA 1
PROJECT SITE PLAN
SCALE: N.T.S.
- -1
OKLAHOMA
• 150
NATIONAL INSTITUTE
OF
STANDARDS AND TECHNOLOGY
RADIO STATION
TOWER 8
REP AIR GUY WIRE
WELLINGTON,
BEE LAKE
RESERVOIR
NUMBER 5
z
;:a
NORTH
POUDRE
RESERVOIR
NUMBER 6
WWVB:
ANCHOR
co
CLEVELAND AVE.
WELLINGTON
CO RD. 62
E CO RD. 60
SHEET LIST:
1. T1 - TITLE SHEET & SITE PLAN
2. C1 - GRADING PLAN
3. C2 CIVIL DETAILS
4. C3 CIVIL SITE PLAN & PROFILE
5. C4 CIVIL GEOMETRICS & DETAILS
6. C5 SUMP PUMP SYSTEM DETAILS
7. S1 ANCHOR EQUIPMENT REPLACEMENT PLAN
8. S2 STRUCTURAL DETAILS
9. E1 ELECTRICAL LEGEND AND DETAILS
10. E2 - ELECTRICAL PLANS
11. E3 - ELECTRICAL ONE-LINE DIAGRAMS
TECHNICAL SPECIFICATIONS LIST:
02581 - ANTENNA TOWER ALIGNMENT
03930 - CONCRETE REHABILITATION
05030 - METAL FINISHES COLD GALVANIZING COMPOUND
05040 - HOT DIPPED GALVANIZING
05500 - METAL FABRICATIONS
024119 - SELECTIVE SITE DEMOLITION
260500 - BASIC ELECTRICAL REQUIREMENTS
260513 WIRES AND CABLES
260526 - GROUNDING AND BONDING
260527 SUPPORTING DEVICES
260533 CONDUITS AND BOXES
260553 - ELECTRICAL IDENTIFICATION
260800 - ELECTRICAL TESTING ACCEPTANCES AND CERTIFICATION
311000 SITE CLEARING
312000 - EARTH MOVING
312319 - DEWATERING
323113 CHAIN LINK FENCES AND GATES
NOTE:
REVISED SHEETS 1 -3
ADDED SHEETS 4-6, 9-11
1 r-----L---------...--<~-----=E--'C~O:'......!.!R!:!.:D·__.:5~8:c._ ___ -J.1----1
VICINITY PLAN
SCALE: N.T.S.
SHEET NUMBER WHERE SECTION NUMBER OR
DETAIL, SECTION OR DETAIL/ELEVATION LETTER
ELEVATION IS TAK EN ----t:::::i.-~---1
PROPERTY IS OWNED
BY NORTH POUDRE
IRRIGATION COMPANY
ADDITIONAL SHEET .._____,_.~SHEET NUMBER WHERE
REFERENCES DETAIL, SECTION OR
ELEVATION IS SHOWN
REFERENCE SYMBOL KEY
RE-ISSUED FOR CONSTRUCTION 10/20/14
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
ENGINEERING, MAINTENANCE, SAFETY and SUPPORT
ORAFTSMAN
R. GORSE
325 BRONYNAY BOULDER, COI.ORADO 80305-3328
RADIO STATION WWVB, WELLINGTON, CO
TOWER 8, WWVB
REPAIR GUY WIRE ANCHOR PROBLEM
TITLE SHEET & SITE PLAN
CLIENT APPROVED BY EMSS DIVISION CHIEF
TIME & FREQUENCY S. SALBER
DESIGN ENGINEER ENGINEER TECHNICIAN
J. HASTINGS, P.E. SUBMITTED BY ENGINEERING SUPERVISOR
NIST SAFEIY CHECKER B. FAKTOR
___________ _L __________ __j_ ____________ ---11<BiPE.RABJicRiN!AS,s ___ hJ,c;;.P<si.iRLILjcjlioiESi7, :...Pm.ER. I DESIGN LEADER
~ OPERATIONS CONSTRUCTION LEADER
& ISSUED FOR CONSTRUCTION 1/29/13 DAK DAK JPI C. COLBURN G. NELSON TIM CLEMANN, P.E .
......... &. ........ __ R_E-_1ss_uE_D _FO_R _co_NSTRU_cn_ON_9/_26/_1. ________ RJ_G ___ JEH _________ JP_I _______ __, DATE
BERM REPAIR ADDED 10/20/14 RJG JEH JPI 10/20/2014
WORK ORDER NUMBER COST CENTER NUMBER FILE NUMBER
6_ ELECTRONIC FILE
t-R~EVl=Sl~ON-+-------DESC-RIPTI_O_N ______ t--BY---t-EN-G-R.-+-SAFEIY-+-FI-RE--+-MAI-NT--,. ,-CH-EC-KE-+R -US-ER--+-SU_PV_. +-------1 Tl - TITLE.DWG
SHEET NUMBER
T1 of
Attachment 4
SB1341-18-RP-0009
bjs2 Highlight bjs2 Highlight bjs2 Highlight bjs2 Highlight bjs2 Highlight bjs2 Highlight
GRADING
SECTION THROUGH BERM ALONG CABLE ALIGNMENT
Attachment 4
SB1341-18-RP-0009
jhastings Polygon jhastings Polygon jhastings Polygon
PROFILE VIEW
PLAN VIEW
LAYOUT AND SPOT ELEVATIONS
BIDIRECTIONAL CLEANOUT DETAIL
SUMP AND AREA DRAIN DETAIL
Attachment 4
SB1341-18-RP-0009
jhastings Polygon jhastings Polygon jhastings Polygon jhastings Polygon jhastings Polygon jhastings Polygon
SITE PLAN - WWVB TOWER 8
SCALE: 1" = 20'C3
CAUSEWAY PROFILE - WWVB TOWER 8
SCALE: 1" = 20'C3
Attachment 4
SB1341-18-RP-0009
SITE PLAN - GEOMETRICS
SCALE: 1" = 20'C4
CAUSEWAY DETAIL - 2
SCALE = N.T.S.C4
CAUSEWAY DETAIL - 1
SCALE = N.T.S.C4
BERM REPAIR DETAIL
SCALE = N.T.S.C4
Attachment 4
SB1341-18-RP-0009
jhastings Polygon
SUMP PUMP SYSTEM DETAIL
N.T.S.C5
Attachment 4
SB1341-18-RP-0009
jhastings Polygon
File details come from the government source that posted it.