S02. VA RRKW Bid Issue Drawings FP-M Updated.pdf

PDF 19 MB Posted

Attached to
Renovate Research K-Wing Federal contract opportunity
Solicitation number
36C25022B0021
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This solicitation is for construction services to renovate the research K-Wing at the Louis Stokes Cleveland VA Medical Center. The contractor shall provide all labor, equipment, supplies and supervision necessary to complete the renovation project, with a period of performance of 496 calendar days from the notice to proceed. The project magnitude is estimated between $10-20 million. The solicitation is for a 100% set-aside for a Service-Disabled Veteran Owned Small Business, and all bidders must be verified in VETBIZ and registered in SAM by the offer due date and award date. Bids are to be submitted in Block 17 of the SF1442 form and will be evaluated based on price. A site visit will be conducted on May 12, 2022 according to the procedures outlined in the solicitation. Requests for information must be submitted by May 12, 2022 to the contracting officer.

The work shall be performed according to the drawings and specifications in the solicitation and coordinated with the VA contracting officer and contracting officer's representative. Public Law 105-339 regarding reporting requirements for previous fiscal year contracts must also be adhered to.

View the file

Other files for this federal contract opportunity

Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONDUIT WITH FIRE STOP GROMMET (SEE ELECTRICAL)

NON-METALLIC CONDUIT WITH FIRE STOP COLLAR (SEE ELECTRICAL)

METALLIC INSULATED CONDUIT WITH FIRE STOP (SEE ELECTRICAL)

CONDUIT SLEEVE WITH FIRE STOP MATERIAL ON

EXTERIOR CIRCUMFERENCE OF CONDUIT AND

INTERIOR OF SLEEVE UPON INSTALLATION OF

CABLING. (SEE ELECTRICAL)FIRE STOP PRODUCTS SIMILAR

TO ALL OTHERS INDICATED

EXCEPT FOR FLOOR

PENETRATIONS.

PIPING WITH FIRE STOP PER DETAIL

ROUND HVAC DUCT WITH FIRE STOP PER DETAIL

HVAC DUCT WITH FIRE STOP PER DETAIL

FIRE RATED PATHWAY AROUND CABLE TRAY (SEE ELECTRICAL)

FIRE RATED WALL

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:4

:0

A

M

0-FX-001

FIRE PROTECTION LEGEND, DETAILS, AND

NOTES

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

FIRE SUPPRESSION PIPING LEGEND

NORTH STAIRWELL

SPRINKLER RISER DETAIL

X -F

X -D

FS

TS

EXISTING TO REMAIN

EXISTING TO BE REMOVED

X

XR

MANUAL AIR VENT

VALVED AND CAPPED FIRE DEPARTMENT VALVE

MAV

FIRE DEPARTMENT VALVE

STAND PIPE

FIRE RISER

FIRE SUPPRESSION PIPING

FLOW SWITCH

TAMPER SWITCH ON VALVE

PRESSURE GAUGE

ELECTRICAL CONTRACTOR

HVAC CONTRACTOR

FIRE SUPPRESSION CONTRACTOR

GENERAL CONTRACTOR

ISOLATION VALVE

GC

FSC

HC

EC

FDV

SP

FR

F

DETAIL MARK

DETAIL NO.

DRAWING

1-FP1-1

LOCATIONS AND ROUTING OF EXISTING PIPING, DUCTWORK AND EQUIPMENT IS PRESUMED FROM

EXISTING DRAWINGS. MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL PRIOR TO

COMMENCEMENT OF CONSTRUCTION. NOTIFY ENGINEER OF ANY CONDITIONS WHICH WILL NOT

PERMIT THE WORK TO BE PERFORMED AS INDICATED ON THESE DRAWINGS.

COORDINATE ALL SHUT-DOWNS OF EXISTING SYSTEMS WITH VA A MINIMUM OF TEN

WORKING DAYS IN ADVANCE.

PRIOR TO INSTALLATION, VERIFY PRECISE LOCATION OF NEW WALL MOUNTED DEVICES WITH

VA AND ARCHITECT. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR PRECISE

LOCATION OF CEILING MOUNTED DEVICES.

PROVIDE ADEQUATE SERVICE CLEARANCE FOR ALL EQUIPMENT. REFER TO INSTRUCTIONS FROM

THE EQUIPMENT MANUFACTURER.

NEW PIPING SHALL NOT BE ROUTED ABOVE ELECTRICAL PANELS. REFER TO ELECTRICAL

DRAWINGS FOR LOCATION OF PANELS.

THE FIRE SUPPRESSION CONTRACTOR SHALL PROVIDE DETAILED DESIGN OF THE SPRINKLER

SYSTEM. REFER TO SPECIFICATIONS.

UNLESS OTHERWISE NOTED NEW SPRINKLERS SHALL BE AS FOLLOWS:

G.1. AREAS WITH CEILINGS: SEMI-RECESSED CONCEALED STYLE WITH CHROME FINISH.

G.2. EXPOSED STRUCTURE: UPRIGHT OR PENDENT TYPE.

THE FIRE PROTECTION SYSTEM IS PERFORMANCE SPECIFIED. ALL SPRINKLER PIPE SIZES

SHALL BE DETERMINED BY FIRE PROTECTION CONTRACTOR, BASED ON HYDRAULIC

CALCULATIONS.

PROVIDE SUPPLEMENTAL DRAINS AS NECESSARY TO PROVIDE 100% SYSTEM DRAINAGE. LOCATE

DRAINS ABOVE ACCESSIBLE CEILINGS.

REFER TO ARCHITECTURAL PLANS FOR EXACT PHASING REQUIREMENTS.

REFER TO SPECIFICATIONS AND SPRINKLER PLANS FOR FIRE SUPPRESSION HAZARD OCCUPANCY

CLASSIFICATIONS.

SPRINKLER PIPING SHALL BE A MINIMUM OF ONE INCH.

UNLESS OTHERWISE STATED ON DRAWINGS OR IN THE SPECIFICATIONS, ALL SPRINKLER HEADS

SHALL BE QUICK RESPONSE.

ALL HEADS SHALL BE UL LISTED AND FM APPROVED.

ALL SPRINKLER ZONES SHALL MATCH SMOKE COMPARTMENTS. REFER TO ARCHITECTURAL

PLANS FOR INFORMATION ON SMOKE COMPARTMENTS, SMOKE PARTITIONS AND FIRE BARRIERS.

CONTRACTOR SHALL REMOVE AND REPLACE CEILING TILES AND GRID AS REQUIRED TO

COMPLETE DEMOLITION AND NEW WORK IN AREAS OUTSIDE OF RENOVATION PROJECT.

CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY TILES OR GRID DAMAGED DUE TO

THIS WORK.

LIMIT OF DEMOLITION

CONNECT TO EXISTING

SCALE: NONE

FIRE SUPPRESSION GENERAL NOTES

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

PROJECT COORDINATION NOTES

BASEMENT

FIRST FLOOR

D

F

D

F

D

F

TO ZONE K-3

SECOND FLOOR

PENTHOUSE

TS FS

MA

MV

FIRE

DEPARTMENT

VALVE

TS FS

X -F

SOUTH STAIRWELL

SPRINKLER RISER DETAIL

SCALE: NONE

ZONE DRAIN VALVE

TEST VALVESIGHT GLASS

UNION

TO ZONE K-2

ZONE DRAIN VALVE

TEST VALVESIGHT GLASS

UNION

FIRE

DEPARTMENT

VALVE

FIRE

DEPARTMENT

VALVE

TS FS

TO ZONE K-1-S

ZONE DRAIN VALVE

TEST VALVESIGHT GLASS

UNION

EXISTING FIRE

DEPARTMENT

VALVE

X-F

X-D

SPRINKLER HEAD LOCATION IN

CEILING TILE DETAIL

SCALE: NONE

2'X4' CEILING TILE

(EITHER LOCATION)

2'X2' CEILING TILE

CL CL CL

CLCL

CL

0'12" 0'36"

SPRINKLERSPRINKLERSPRINKLER

FSTS

TO ZONE K-1-N

THIS PROJECT CONSISTS OF MULTIPLE TRADES OF WORK PERFORMED WITHIN AN EXISTING BUILDING, ALL OF WHICH ALLOWS VERY LITTLE PERMISSIBLE RANGE OF VARIATION. THE CONTRACTOR SHALL TAKE CAREFUL CONSIDERATION WITH THE COORDINATION AND INSTALLATION OF THE MULTITUDE OF NEW SYSTEMS WHILE

ALSO ACCOMMODATING ANY EXISTING SYSTEMS TO REMAIN.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL TRADES ASSOCIATED WITH THIS

PROJECT AND ISSUING COORDINATION PLANS PRIOR TO COMMENCEMENT OF EACH PHASE OF

CONSTRUCTION.

THE COORDINATION DRAWINGS SHALL ILLUSTRATE ALL SYSTEMS IN PLACE. NO EXCEPTIONS! THE CONTRACTOR SHALL SHOW ALL NECESSARY OFFSETS, TRANSITIONS, ETC. AS REQUIRED IN ORDER TO

ACCOMMODATE CONDITIONS IDENTIFIED IN THE FIELD.

IF CONFLICTS ARE IDENTIFIED DURING THE DEVELOPMENT OF COORDINATION PLANS, THE CONTRACTOR SHALL NOTIFY THE VA COR, ARCHITECT, AND/OR ENGINEER OF ANY CONDITIONS WHICH WILL NOT PERMIT

THE WORK TO BE PERFORMED AS INDICATED ON THE PROJECT PLANS.

COMPLETED SET OF COORDINATION PLANS ISSUED FOR REVIEW SHALL CONFIRM THAT THE CONTRACTOR FULLY UNDERSTANDS THE PROJECT CONSTRAINTS AND ALL KNOWN CONFLICTS HAVE BEEN ADDRESSED.

A.

B.

C.

D.

E.

FIRE STOPPING WALL AND FLOOR DETAIL

SCALE: NONE

Revisions: Date:

BID ISSUE 1/20/2022

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

OH1

Elec Vault

BF458

Ex Stair

BS21

Haz

BF424

Quarantine

BF465

Animal Ward-1

BF462-1

Security-1

BF468A-1

Procedure

BF464B

Procedure

BF464A

Vest

BF464

Bedding / Food

BF346

Animal Ward-1

BF455-1

Haz Waste

BF469

Exit Passage

BF501

Elev

BF-

Room

BF477

Food

BF459

Specimen

BF431

Molecular Biology

Lab

BF440

Tlt

BF423

Office

BF426

Shop

BF450

Exit Passage

BF403

Corridor-1

BF421-1

Corridor-1

BF350-1

Animal Ward-1

BF461-1

Viewing

BF422

Entry

BF 473

Elec

BF468

Animal Reception-1

BF466-1

HVAC-1

BF467-1

Procedure

BF468D

Animal Ward-1

BF460-1

Corridor

BF472

Mach Rm

BF457

Corridor

BF471

Animal Ward-1

BF456-1

Animal Ward-1

BF452-1

Bottle Washer-1

BF345-1

Ex Stair

BS24

Shower-1

BF428-1

Equipment

BF412

Autopsy

BF427

Equipment

BF411

Exit Passage

BF404

Refrigerator

BF430

Evs

BF429

Animal Ward-1

BF453-1

Animal Ward-1

BF451-1

Storage

BF348

Sterilizer-1

BF347A-1

Cage Assembly-1

BF346A-1

Animal Ward-1

BF454-1

Necrospy

BF463

Work

BF441

Procedure

BF468C

Animal Room

BF342

Cage Washer

BF344

Men's Restroom

BF322

Office

BF321

Corridor

BF340A

Clean Cage Prep

BF343

Corridor

BF310

Supplies

BF341

Post Operative

Ward

BF325

Corridor

BF320

Storage

BF324

Women's Restroom

BF323

Corridor

BF340

OH1

OH1

OH2

L

L

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:1

A

M

1-FX-102

PHASE 1 - BASEMENT FIRE PROTECTION

PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 1 - BASEMENT FIRE PROTECTION PLAN 1N

GENERAL NOTES

A. SPRINKLER WORK AT BASEMENT LEVEL WILL OCCUR THROUGHOUT COURSE OF CONSTRUCTION.

COORDINATE ACCESS TO CAGE WASHER AREA WITH VA COR.

B. PROVIDE NEW SPRINKLERS WHERE CEILING IS REPLACED. SPRINKLER TYPE SHALL MATCH EXISTING.

FIRE PROTECTION LEGEND

REWORK SPRINKLER SYSTEM IN OUTLINED AREA IN ORDER TO ACCOMMODATE

DEMOLITION AND NEW WORK OF MECHANICAL AND ELECTRICAL SYSTEMS. PROVIDE

NEW SPRINKLER HEADS, WHERE NECESSARY, IN ORDER TO PROVIDE FULL COVERAGE

OF SPACE.

ORDINARY HAZARD OCCUPANCY - GROUP 1OH1

# CODED NOTES

PROVIDE NEW SPRINKLER AND DRAIN RISERS UP THROUGH STAIRWELL. CONNECT TO EXISTING

SERVICES IN BASEMENT. RISERS SHALL REPLACE EXISTING. EXISTING RISERS SHALL BE REMOVED

DURING PHASE 2. REFER TO SUBSEQUENT DRAWINGS.

LIGHT HAZARD OCCUPANCYL

ORDINARY HAZARD OCCUPANCY - GROUP 2OH2

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

OH1OH1OH1

OH1

OH1

OH1

OH1

OH1

OH1

OH1

OH1

OH1 OH1

OH1

OH1

LLLLL

L

L

L

L

L

L

L

L L L

L

L

L

L

L

EX Stair

2S24

EX Stair

2S21

Autoclave

2F438

Office 04

2F443

Office 03

2F445

Office 02

2F446

Office 01

2F447

Office 05

2F441

Office 10

2F423

Office 09

2F425

Office 08

2F426

Office 07

2F427

Office 06

2F434

Hskp

2F412

Lab 05 Eq Alcove

2F430C

Eyewash

2F430A

Laboratory

2F422

Labs 09-10 Eq Alcove

2F420A

Labs 01-02 Eq Alcove

2F440B

Laboratory 01 Hise

2F448

Laboratory

2F444

Lab 03 Eq Alcove

2F440A

Eq Alcove

2F440C

Passage

2F440

Laboratory

Bonomo

2F436

Passage

2F430

Laboratory

Donskey

2F431

Labs 06-07 Eq Alcove

2F430B

Labs 08-09 Eq Alcove

2F420B

IT

2F428A

Laboratory

2F424

Lounge

2F411

Womens

2F414

Mens

2F416

Nitrogen / Ice

2F428

Equipment

2F417

Passage

2F410

Passage

2F420

TS

FS

1 2

X-SPRINKLER

RISER

Cold

2F432

Equipment

2F415

Elec

2F413

Simulation Center

2F433

Elec

2F449

Laboratory 10 Pieper

2F421

Laboratory

2F435

Laboratory

2F442

Laboratory

Bonomo

2F437

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:2

A

M

1-FX-104

PHASE 1 - SECOND FLOOR FIRE PROTECTION

PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

# CODED NOTES

1 PROVIDE NEW SPRINKLER AND DRAIN RISER UP THROUGH SOUTH STAIRWELL. CONNECT TO EXISTING MAINS AT BASEMENT LEVEL AND ROUTE UP THROUGH STAIRWELL TO PENTHOUSE LEVEL. EXISTING RISERS SHALL REMAIN ACTIVE UNTIL PHASE 2. NEW RISER LOCATIONS SHALL BE COORDINATED IN FIELD. NEW RISERS SHALL BE SIZED FOR SERVICE AREAS OUTLINED ON FIRST, SECOND, AND PENTHOUSE LEVELS.

PROVIDE NEW SPRINKLER ZONE VALVE (WITH TAMPER SWITCH) AND FLOW SWITCH (ZONE K-2). PROVIDE NEW DRAIN AND CONNECT TO NEW DRAIN RISER. PROVIDE NEW FIRE DEPARTMENT VALVE ON SPRINKLER

RISER WITHIN STAIRWELL.

EXISTING SPRINKLER RISER AND DRAIN RISER IN STAIRWELL SHALL REMAIN ACTIVE UNTIL PHASE 2. REFER

TO PHASE 2 DRAWINGS FOR ADDITIONAL INFORMATION.

PROVIDE FREEZE-PROOF (DRY) SPRINKLER HEAD FOR COLD ROOM.

FIRE PROTECTION LEGEND

REMOVE ALL SPRINKLER PIPING AND HEADS THAT SERVE HATCHED AREA COMPLETELY.

WHERE PIPING IS IDENTIFIED AS SERVING ADJACENT SPACES, CONTRACTOR SHALL

MAINTAIN PIPING AS ACTIVE. ACTIVE PIPING SERVING ADJACENT SPACES SHALL BE

REWORKED WITH NEW AS REQUIRED TO ACCOMMODATE ALL NEW SYSTEMS. PROVIDE

ALL NEW MAINS, BRANCH PIPING, AND SPRINKLERS IN HATCHED AREA. HATCHED AREA

SHALL BE SERVED FROM SOUTH STAIRWELL SPRINKLER ZONE K-2.

LIGHT HAZARD OCCUPANCY

ORDINARY HAZARD OCCUPANCY - GROUP 1

ORDINARY HAZARD OCCUPANCY - GROUP 2

L

OH1

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 1 - SECOND FLOOR FIRE PROTECTION

PLAN 1

OH2

N

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

OH1

OH1

Ex Mechanical

Room

3F440

Ex Mechanical

Room

3F410

Stair 24-2

3S24-2

Stair 21-2

3S21-2

X-SPRINKLER

RISER

1 2

TS

FS

L

FMS Room

3F412

Mechanical Penthouse

3F411

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:2

A

M

1-FX-105

PHASE 1 - ROOF/PENTHOUSE FIRE

PROTECTION PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 1 - ROOF/PENTHOUSE FIRE PROTECTION

PLAN 1

# CODED NOTES

1 PROVIDE NEW SPRINKLER AND DRAIN RISER UP THROUGH SOUTH STAIRWELL. CONNECT TO EXISTING MAINS AT BASEMENT LEVEL AND ROUTE UP THROUGH STAIRWELL TO PENTHOUSE LEVEL. EXISTING RISERS SHALL REMAIN ACTIVE UNTIL PHASE 2. NEW RISER LOCATIONS SHALL BE COORDINATED IN FIELD. NEW RISERS SHALL BE SIZED FOR SERVICE AREAS OUTLINED ON FIRST, SECOND, AND PENTHOUSE LEVELS.

PROVIDE NEW SPRINKLER ZONE VALVE (WITH TAMPER SWITCH) AND FLOW SWITCH (ZONE K-3). PROVIDE NEW DRAIN AND CONNECT TO NEW DRAIN RISER. PROVIDE NEW FIRE DEPARTMENT VALVE ON SPRINKLER

RISER WITHIN STAIRWELL.

EXISTING SPRINKLERS IN FAN PENTHOUSE SHALL REMAIN.

FIRE PROTECTION LEGEND

REMOVE ALL EXISTING SPRINKLER SYSTEMS LOCATED IN PENTHOUSE COMPLETELY.

REMOVE EXISTING RISERS BACK TO ACTIVE MAINS AND CAP. PROVIDE ALL NEW MAINS,

BRANCH PIPING, AND SPRINKLERS IN HATCHED AREA. SPRINKLER ABOVE AND BELOW

ALL DUCTWORK. PROVIDE PROTECTIVE CAGES ON HEADS THAT ARE LOCATED AT

ELEVATIONS 7’-6” OR LESS AFF. HATCHED AREA SHALL BE SERVED FROM SOUTH

STAIRWELL SPRINKLER ZONE K-3.

LIGHT HAZARD OCCUPANCY

ORDINARY HAZARD OCCUPANCY - GROUP 1

ORDINARY HAZARD OCCUPANCY - GROUP 2

L

OH1

OH2

N

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

OH2

OH1

OH2

OH2

OH2

OH1

OH2

OH2

OH2

OH1

OH1

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

L

X-SPRINKLER

RISER

L

X

F X

F

X

F X

F

CAP

CAP

TS

FS

ZONE K-1-N

ZONE K-1-S

Isolation Station 04

1F479

Isolation Station 03

1F478

Private Station 05

1F481

EX Stair

1S21

EX Elev

1S25

Hall

1F470A

Conference

1F455

Soiled Linen

1F493A

Elec

1F456

Equip Stor

1F494

Equip Repair

1F495

HSK (EMS)

1F493

Medical Supply

1F491 Med

1F489

Dialysis Supply

1F487

Soiled Util

1F485

Private Station 01

1F476

Staff Lounge /

Lkrs

1F474

Private Station 07

1F483

Private Station 06

1F482

Bulk Supply

1F488

Patient Toilet

1F484

Staff Toilet

1F471

Office 1

1F473

Office 2

1F472

Office 1

1F466

Office 2

1F465

Office 3

1F464

Office 4

1F463

Office 5

1F462

Office 6

1F461

EX Stair

1S24

Staff Lounge

1F454

Womens

1F453

Passage

1F450A

Conference

1F451

Mens

1F452

Nourish / Linen

1F475

Passage

1F470

Corridor

1F450B

CC 2

1F480C

CC 1

1F480B

Lab Circulation-1

1F460-1 Stair

1F455A

Receiving

1F460R

Pat Hold

1F480A

Dialysis Circulation

1F480E

Crash Cart-1

1F480D-1

Crash Cart-2

1F480D-2

1F460J

1F460H

1F460K

Copy

1F460G

Lab Circulation-2

1F460-2

1F460S

1F460T

Passage

1F490B

Private Station 02

1F477

Passage-1

1F490A-1

Elec

1F486

Water Treat /

Dialy Prep

1F492

Passage-2

1F490A-2

Nurse Sta

1F480

16 / Recept

1F460A

1F460Q

1F460B

1F460P

1F460C

1F460D

1F460N

1F460M

1F460E

1F460F

1F460L

TSFS

ZONE K-1-N

ZONE K-1-S

1F460U

1F460V

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:0

A

M

2-FX-103

PHASE 2 - FIRST FLOOR FIRE PROTECTION

PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

# CODED NOTES

1 CONNECT TO NEW SPRINKLER RISER (INSTALLED IN PHASE 1). PROVIDE NEW SPRINKLER ZONE VALVE (WITH TAMPER SWITCH) AND FLOW SWITCH (ZONE K-1-S). CONNECT INTO DRAIN RISER. PROVIDE NEW FIRE

DEPARTMENT VALVE ON SPRINKLER RISER WITHIN STAIRWELL.

DISCONNECT SPRINKLER MAIN AT APPROXIMATE POINT INDICATED. CORRIDOR SPRINKLER MAIN SOUTH OF SMOKE BARRIER SHALL BE CONNECTED TO NEW SPRINKLER ZONE K-1-S. CAP DISCONNECTED LINE.

CONNECT TO EXISTING SPRINKLER RISER. PROVIDE NEW SPRINKLER ZONE VALVE (WITH TAMPER SWITCH)

AND FLOW SWITCH (ZONE K-1-N). CONNECT INTO EXISTING DRAIN RISER.

DISCONNECT SPRINKLER MAIN AT APPROXIMATE POINT INDICATED. CORRIDOR SPRINKLER MAIN SHALL BE

CONNECTED TO NEW SPRINKLER ZONE K-1-N. CAP DISCONNECTED LINE.

CONNECT NEW SPRINKLER ZONE K-1-S MAIN INTO EXISTING BRANCH LINE(S) SERVING ROOM K119. FIELD

VERIFY LOCATION AND QUANTITY OF POINTS OF CONNECTION.

EXISTING SPRINKLERS IN ROOM K119 SHALL REMAIN.

AS PART OF PHASE 2, REMOVE REMAINDER OF ORIGINAL SPRINKLER RISER(S) SERVING FIRST FLOOR THROUGH PENTHOUSE LEVEL COMPLETELY. CAP AT BASEMENT LEVEL. INFILL FLOOR OPENINGS WITH

CONCRETE AND PATCH FLOORING TO MATCH EXISTING.

FIRE PROTECTION LEGEND

EXCEPT WHERE SPECIFICALLY NOTED, REMOVE ALL SPRINKLER PIPING AND HEADS

THAT SERVE HATCHED AREA COMPLETELY. WHERE PIPING IS IDENTIFIED AS SERVING

ADJACENT SPACES, CONTRACTOR SHALL MAINTAIN PIPING AS ACTIVE. ACTIVE PIPING

SERVING ADJACENT SPACES SHALL BE REWORKED WITH NEW AS REQUIRED TO

ACCOMMODATE ALL NEW SYSTEMS. PROVIDE ALL NEW MAINS, BRANCH PIPING, AND

SPRINKLERS IN HATCHED AREA. HATCHED AREA SHALL BE SERVED FROM SOUTH

STAIRWELL SPRINKLER ZONE K-1-S.

EXCEPT WHERE SPECIFICALLY NOTED, REMOVE ALL SPRINKLER PIPING AND HEADS

THAT SERVE HATCHED AREA COMPLETELY. WHERE PIPING IS IDENTIFIED AS SERVING

ADJACENT SPACES, CONTRACTOR SHALL MAINTAIN PIPING AS ACTIVE. ACTIVE PIPING

SERVING ADJACENT SPACES SHALL BE REWORKED WITH NEW AS REQUIRED TO

ACCOMMODATE ALL NEW SYSTEMS. PROVIDE ALL NEW MAINS, BRANCH PIPING, AND

SPRINKLERS IN HATCHED AREA. HATCHED AREA SHALL BE SERVED FROM NORTH

STAIRWELL SPRINKLER ZONE K-1-N.

LIGHT HAZARD OCCUPANCYL

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 2 - FIRST FLOOR FIRE PROTECTION PLAN 1

ORDINARY HAZARD OCCUPANCY - GROUP 1

ORDINARY HAZARD OCCUPANCY - GROUP 2

OH1

OH2

N

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

OH1

OH1

X-SPRINKLER

RISER

TS

FS

Ex Mechanical

Room

3F440

Ex Mechanical

Room

3F410

Stair 24-2

3S24-2

Stair 21-2

3S21-2

3F412

FMS Room

Mechanical Penthouse

3F411

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:1

A

M

2-FX-105

PHASE 2 - ROOF/PENTHOUSE FIRE

PROTECTION PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

# CODED NOTES

1 EXISTING SPRINKLERS IN FAN PENTHOUSE SHALL REMAIN.

FIRE PROTECTION LEGEND

REWORK SPRINKLER SYSTEM IN OUTLINED AREA IN ORDER TO ACCOMMODATE

DEMOLITION AND NEW WORK OF MECHANICAL AND ELECTRICAL SYSTEMS. PROVIDE

NEW SPRINKLER HEADS, WHERE NECESSARY, IN ORDER TO PROVIDE FULL COVERAGE

OF SPACE. SPRINKLER ABOVE AND BELOW ALL DUCT MAINS.

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 2 - ROOF/PENTHOUSE FIRE PROTECTION

PLAN 1

LIGHT HAZARD OCCUPANCY

ORDINARY HAZARD OCCUPANCY - GROUP 1

ORDINARY HAZARD OCCUPANCY - GROUP 2

L

OH1

OH2

N

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:4

:0

A

M

0-P-001

PLUMBING SYMBOLS, SCHEDULES, AND

NOTES

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

THIS PROJECT CONSISTS OF MULTIPLE TRADES OF WORK PERFORMED WITHIN AN EXISTING BUILDING, ALL OF WHICH ALLOWS VERY LITTLE PERMISSIBLE RANGE OF VARIATION. THE CONTRACTOR SHALL TAKE CAREFUL CONSIDERATION WITH THE COORDINATION AND INSTALLATION OF THE MULTITUDE OF NEW

SYSTEMS WHILE ALSO ACCOMMODATING ANY EXISTING SYSTEMS TO REMAIN.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL TRADES ASSOCIATED WITH THIS

PROJECT AND ISSUING COORDINATION PLANS PRIOR TO COMMENCEMENT OF EACH PHASE OF

CONSTRUCTION.

THE COORDINATION DRAWINGS SHALL ILLUSTRATE ALL SYSTEMS IN PLACE. NO EXCEPTIONS! THE CONTRACTOR SHALL SHOW ALL NECESSARY OFFSETS, TRANSITIONS, ETC. AS REQUIRED IN ORDER TO

ACCOMMODATE CONDITIONS IDENTIFIED IN THE FIELD.

IF CONFLICTS ARE IDENTIFIED DURING THE DEVELOPMENT OF COORDINATION PLANS, THE CONTRACTOR SHALL NOTIFY THE VA COR, ARCHITECT, AND/OR ENGINEER OF ANY CONDITIONS WHICH WILL NOT

PERMIT THE WORK TO BE PERFORMED AS INDICATED ON THE PROJECT PLANS.

A COMPLETED SET OF COORDINATION PLANS ISSUED FOR REVIEW SHALL CONFIRM THAT THE

CONTRACTOR FULLY UNDERSTANDS THE PROJECT CONSTRAINTS AND ALL KNOWN CONFLICTS HAVE

BEEN ADDRESSED.

PLUMBING GENERAL NOTES

A. LOCATIONS AND ROUTING OF EXISTING PIPING, DUCTWORK, AND EQUIPMENT IS PRESUMED FROM EXISTING

DRAWINGS. MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL PRIOR TO COMMENCEMENT OF

CONSTRUCTION. NOTIFY ENGINEER OF ANY CONDITIONS WHICH WILL NOT PERMIT THE WORK TO BE

PERFORMED AS INDICATED ON THESE DRAWINGS.

B. COORDINATE ALL SHUT-DOWNS OF EXISTING MECHANICAL SYSTEMS WITH VA A MINIMUM OF TEN WORKING

DAYS IN ADVANCE.

C. PRIOR TO INSTALLATION, VERIFY PRECISE LOCATION OF NEW WALL MOUNTED DEVICES WITH VA AND

ARCHITECT.

D. PROVIDE ADEQUATE SERVICE CLEARANCE FOR ALL MECHANICAL EQUIPMENT. REFER TO INSTRUCTIONS

FROM THE EQUIPMENT MANUFACTURER.

E. NEW PIPING SHALL NOT BE ROUTED ABOVE ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS FOR

LOCATION OF PANELS.

F. WHERE EXISTING FIXTURES ARE TO BE REMOVED, REMOVE ALL ASSOCIATED BRANCH PIPING WHICH IS NOT

TO BE REUSED. REMOVE PIPING TO MAINS AND CAP.

G. CONTRACTOR SHALL REMOVE AND REPLACE CEILING TILES AND GRID AS REQUIRED TO COMPLETE DEMOLITION AND NEW WORK IN AREAS OUTSIDE OF RENOVATION PROJECT. CONTRACTOR SHALL BE

RESPONSIBLE FOR REPLACING ANY TILES OR GRID DAMAGED DUE TO THIS WORK.

H. REFER TO ARCHITECTURAL PLANS FOR SCHEDULING/PHASING OF WORK PERFORMED ABOVE FIRST FLOOR

SPS DEPARTMENT CEILINGS.

I. CONTRACTOR SHALL PROVIDE NEW CHASE ENCLOSURES WHERE EXISTING STORM, SANITARY, WATER, VENT RISERS ARE TO REMAIN, BUT ARE UNCOVERED/EXPOSED DURING CONSTRUCTION. ENCLOSURES

SHALL FULLY CONCEAL PIPING. COORDINATE REQUIREMENTS WITH GENERAL TRADES.

J. DOMESTIC HOT WATER LINES SHALL BE MAINTAINED AT OR ABOVE 125 DEGREE F.

K. ALL NEW DOMESTIC WATER LINES (CW, HW, HWR) SHALL BE FLUSHED AND DISINFECTED BY CONTRACTOR PRIOR TO FINAL INSPECTION. REFER TO SPECIFICATION SECTION 22 11 00 FOR ADDITIONAL INFORMATION.

L. PROVIDE MIXING VALVE AT OR NEAR ALL FAUCETS MOUNTED IN ACCESSIBLE LOCATION. NOTE FIXTURES

WITH INTEGRAL MIXING VALVES IN SPECIFICATION SECTION 22 40 00.

M. DO NOT USE AERATORS ON LAVATORIES OR SINKS.

N. MINIMIZE LENGTH OF DEAD LEGS TO TWO (2) PIPE DIAMETERS OR LESS. NOTIFY VA COR OF ANY CONFLICTS

PRIOR TO INSTALLATION.

PROJECT COORDINATION NOTES

A.

B.

C.

D.

E.

PLUMBING SYMBOLS:

LIMIT OF DEMOLITION

AND EXISTING WORK

POINT OF CONNECTION BETWEEN NEW

CHECK VALVE

BALANCING VALVE

UNION

BALL VALVE

DOMESTIC HOT WATER RETURN

DOMESTIC HOT WATER SUPPLY

DOMESTIC COLD WATER SUPPLY

ACID WASTE

GENERAL CONTRACTOR

PLUMBING CONTRACTOR

PLUMBING VENT

AW

ST

G.C.

P.C.

EQUIPMENT OR FIXTURE MARK

REFERENCE TO CODED NOTE

SAN SANITARY WASTE BELOW FLOOR

EXISTING TO BE REMOVED

X-X EXISTING TO REMAIN

XR-X EXISTING TO BE REMOVED

SAN SAW CUT FLOOR FOR INSTALLATION OR REMOVAL OF PIPE

V

F FIRE SUPPRESSION PIPING

STORM DRAIN

X-1

X

MANUAL BALANCING VALVE ASSEMBLY

PIPE DOWN

PIPE RISE UP

PIPE CAP

BRANCH TOP CONNECTION

BRANCH BOTTOM CONNECTION

FLOOR DRAIN (F.D.)

BRANCH SIDE CONNECTIONCW

EXISTING TO REMAIN

ELECTRICAL CONTRACTOR

TEMPERATURE CONTROL CONTRACTOR

HVAC CONTRACTOR

FIRE SUPPRESSION CONTRACTOR

E.C.

F.C.

T.C.

H.C.

SINK

WATER CLOSET

DRINKING FOUNTAIN

URINAL

LAVATORY

S

WC

DF

U

L

FLUSH VALVEFV

SHOWERSH

HOSE BIBBHB

MOP BASINMB

EMERGENCY EYE WASHEEW

RISER WITH ISOLATION VALVE

NATURAL GAS PIPING

SHUTOFF VALVE BOXSVB

TRAP PRIMERTP

CW

HW

HWR

WATER DIAGRAMWD

DEIONIZED WATER PIPING

LABORATORY VACUUM PIPING

LABORATORY AIR PIPINGLA

LV

DEI

G

PLUMBING VENT (ACID RESISTANT)AV

SANITARY WASTESAN

CLEAN-OUTC.O.

RECIRCULATED DEIONIZED WATERDEIR

TEPID WATERTW

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE

BRANCH PIPE SIZE

VENT

P-103

NOTES:

1. PROVIDE THERMOSTATIC MIXING VALVE FOR EACH LAVATORY AND SINK.

2. PROVIDE TRAP PRIMER FOR EACH FLOOR DRAIN.

3. WATER CONNECTIONS BY OTHERS.

WALL-HUNG

WATER CLOSET

1-1/2"Ø - 4"Ø 2"Ø

SANHWCW

DEI

DEI

(RECIRC)

STORM

P-403

WALL-HUNG

LAVATORY

1/2"Ø 1/2"Ø 1-1/2"Ø 1-1/2"Ø- - -

P-502 MOP BASIN 3/4"Ø 3/4"Ø 3"Ø 1-1/2"Ø- - -

P-505

WALL-HUNG

CLINIC SINK

1-1/2"Ø 3/4"Ø 4"Ø 2"Ø- - -

P-528

STAINLESS STEEL

DROP-IN SINK

1/2"Ø 1/2"Ø 1-1/2"Ø 1-1/2"Ø- - -

P-555

LAB SINK INTEGRAL

COUNTER

3/4"Ø 3/4"Ø 1-1/2"Ø 1-1/2"Ø- - -

P-707

EMERGENCY

EYEWASH AND

SHOWER

3/4"Ø 3/4"Ø 2"Ø 1-1/2"Ø- - -

P-807

DEIONIZED WATER

FAUCET

- - - -1/2"Ø 1/2"Ø -

FD-B FLOOR DRAIN - - 4"Ø 2"Ø- - -

FD-S FLOOR SINK - - 4"Ø 2"Ø- - -

RD-1 ROOF DRAIN - - - -- - 4"Ø

ORD-1

OVERFLOW ROOF

DRAIN

- - - -- - 4"Ø

FD-C FLOOR DRAIN - - 4"Ø 2"Ø- - -

MEDICAL VACUUM PIPING

OXYGEN PIPINGOX

MV

MEDICAL GAS GENERAL NOTES

PROVIDE MEDICAL GAS PIPING SYSTEMS AND PIPE LABELS COMPLYING WITH REQUIREMENTS OF NFPA 99

"STANDARD FOR HEALTH CARE FACILITIES", LATEST EDITION.

INSTALLATION AND CERTIFICATION SHALL COMPLY WITH ASSE/ANSI SERIES 6000, "PROFESSIONAL QUALIFICATIONS STANDARDS FOR MEDICAL GAS SYSTEMS INSTALLERS, INSPECTORS AND VERIFIERS".

PROVIDE COMPATIBLE ACCESSORIES, TUBE, FITTING, AND VALVES FOR EACH SYSTEM.

1. OUTLET / INLET STYLE: DISS

2. MEDICAL GAS TUBE, FITTINGS AND JOINTS: PRE-CLEANED AND SEALED COPPER TUBE: ASTM B 88, TYPE K OR TYPE L, WATER TUBE, SEAMLESS, DRAWN TEMPER, CLEANED FOR MEDICAL GAS USE, PURGED, AND WITH ENDS SEALED.

3. MEDICAL SYSTEM ACCESSORIES: PROVIDE THE MEDICAL GAS SYSTEM ACCESSORIES FROM

MANUFACTURER OF EXISTING ACCESSORIES, COMPATIBLE WITH EXISTING SYSTEMS.

4. SERVICE OUTLETS: INCLUDE BRASS VALVE AND BODY BLOCK WITH SEALS IN ROUGH-IN AND FINISHING ASSEMBLIES, STEEL OUTLET BOX AND COVER PLATE; 3/8 INCH TYPE K OR L COPPER TUBE

BRAZED TO VALVE; AND PRESSURE OUTLETS WITH AUTOMATIC SECONDARY SERVICE VALVE TO

PREVENT GAS FLOW WHEN PRIMARY VALVE IS REMOVED. DISS COUPLING SHALL BE INDEXED TO

PREVENT INTERCHANGE BETWEEN SERVICES, CONSTRUCTED TO PERMIT ONE HANDED

CONNECTION AND REMOVAL OF EQUIPMENT WITH POSITIVE LOCKING RING WHICH RETAINS

EQUIPMENT STEM IN VALVE DURING USE. OUTLET/INLET TYPE OF CONNECTION SHALL BE

COORDINATED WITH THE OWNER PRIOR TO ORDERING EQUIPMENT.

INSTALL LABELING ON VALVES, VALVE BOX COVERS, AND ALARM PANELS IN ACCORDANCE WITH

REQUIREMENTS OF NFPA 99 AND VA STANDARDS. CAPTIONS AND COLOR CODING: PER THE

REQUIREMENTS OF NFPA 99 AND VA STANDARDS.

COORDINATE ALL SHUT-DOWNS IF EXISTING MEDICAL GAS AND VACUUM SYSTEMS WITH VA A MINIMUM OF

TEN WORKING DAYS IN ADVANCE.

PRIOR TO INSTALLATION, VERIFY PRECISE LOCATION OF NEW WALL MOUNTED DEVICES WITH VA AND

ARCHITECT.

PROVIDE ADEQUATE SERVICE CLEARANCE FOR ALL EQUIPMENT. REFER TO INSTRUCTIONS FROM THE

EQUIPMENT MANUFACTURER.

NEW PIPING SHALL NOT BE ROUTED ABOVE ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS FOR

LOCATION OF PANELS.

WHERE EXISTING FIXTURES ARE TO BE REMOVED, REMOVE ALL ASSOCIATED BRANCH PIPING WHICH IS

NOT TO BE REUSED. REMOVE PIPING TO MAINS AND CAP REMAINING PIPES.

REFER TO ARCHITECTURAL PLANS FOR PROJECT PHASING REQUIREMENTS.

CONTRACTOR SHALL REMOVE AND REPLACE CEILING TILES AND GRID AS REQUIRED TO COMPLETE DEMOLITION AND NEW WORK IN AREAS OUTSIDE OF RENOVATION PROJECT. CONTRACTOR SHALL BE

RESPONSIBLE FOR REPLACING ANY TILES OR GRID DAMAGED DUE TO THIS WORK.

CONTRACTOR SHALL COMPLETE CERTIFICATION OF SYSTEMS FOR EACH PHASE OF CONSTRUCTION.

CERTIFICATION OF PHASE SHALL BE COMPLETED PRIOR TO SUBSEQUENT CONSTRUCTION PHASE.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

SERVICE SIZE TO VALVE BOX

MARK

IA

MVB-1 3/4" - - -

NOWAGDOX

MA

1"

MV CO2

MEDICAL GAS ZONE VALVE BOX SCHEDULE

V

M B MEDICAL ZONE VALVE BOX

P-804 WALL HYDRANT - - -- - -3/4"Ø

P-755

DECK-MOUNTED

EYEWASH

3/4"Ø 3/4"Ø - -- - -

P-801

NON-FREEZE

WALL HYDRANT

3/4"Ø - - -- - -

P-809

DIALYSIS

WALL BOX

SEE

NOTE 3

- 2"Ø 1-1/2"- - -

P-577

LAB SINK FOOT

PEDAL FAUCET

3/4"Ø 3/4"Ø 1-1/2"Ø 1-1/2"Ø- - -

P-708

EMERGENCY EYE

AND FACE WASH

3/4"Ø 3/4"Ø 2"Ø 1-1/2"Ø- - -

FD-T TRENCH DRAIN - - 4"Ø 2"Ø- - -

CONDUIT WITH FIRE STOP GROMMET (SEE ELECTRICAL)

NON-METALLIC CONDUIT WITH FIRE STOP COLLAR (SEE ELECTRICAL)

METALLIC INSULATED CONDUIT WITH FIRE STOP (SEE ELECTRICAL)

CONDUIT SLEEVE WITH FIRE STOP MATERIAL ON

EXTERIOR CIRCUMFERENCE OF CONDUIT AND

INTERIOR OF SLEEVE UPON INSTALLATION OF

CABLING. (SEE ELECTRICAL)FIRE STOP PRODUCTS SIMILAR

TO ALL OTHERS INDICATED

EXCEPT FOR FLOOR

PENETRATIONS.

PIPING WITH FIRE STOP PER DETAIL

ROUND HVAC DUCT WITH FIRE STOP PER DETAIL

HVAC DUCT WITH FIRE STOP PER DETAIL

FIRE RATED PATHWAY AROUND CABLE TRAY (SEE ELECTRICAL)

FIRE RATED WALL

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:4

:0

A

M

0-P-501

PLUMBING DETAILS Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

NOT TO SCALE

PENETRATION OF FIRE/SMOKE BARRIERSTYPICAL METHOD OF SECURING HANGER RODS IN CONCRETE SLABS AND BEAMS

NOT TO SCALENOT TO SCALE

NOT TO SCALENOT TO SCALE

NOT TO SCALE

NOT TO SCALENOT TO SCALENOT TO SCALE

MIXING VALVE DETAIL

ADA LAVATORY DETAILVENT THROUGH ROOF DETAILDOMESTIC HOT WATER RETURN VALVE ASSEMBLY DETAIL

FLOOR DRAIN (FD-C) DETAILTYPICAL ROOF DRAIN DETAIL

TRAP PRIMER DETAIL

INSULATED

PIPE OR

DUCT

DRYWALL PARTITION

3/4" [19mm] APPROVED

FIRESTOP INSULATION WITH

VAPOR BARRIER

[152mm]

6"

[152mm]

6"

FIRESTOP

MATERIAL

PARTITION SUPPORT

MASONRY

PARTITION

[152mm]

6"

[152mm]

6"

PARTITION OR CHASE PENETRATION

FLOOR OR DECK PENETRATION

WELD

1/4" [6mm]∅

ANCHOR ROD FOR

NEW CONSTRUCTION

PIPE SLEEVE

WHERE SPECIFIED

3/4" [19mm]

APPROVED FIRESTOP

INSULATION WITH

VAPOR BARRIER

FIRESTOP MATERIAL

FLOOR

INSULATED

PIPE OR DUCT

APPLICABLE TO PENETRATIONS OF

ALL FIRE RATED MEMBRANES, IN

ACCORDANCE WITH NFPA 101.

REFER TO SPECIFICATIONS SECTION

FOR FIRE STOPPING SYSTEMS.

NOTE:

1.

STEEL EXPANSION SHIELD FOR

THIS TYPE SHALL BE USED ONLY

INSERTS FOR NEW CONSTRUCTION

FOR EXISTING CONSTRUCTION AND

3/8" (10 MM) MIN DIA EXPANSION BOLTS

NUTS & WASHERS

HANGER RODS

3/8" (10 MM) MIN DIA

FLOOR SLAB

CLIP

ANGLE

HANGER RODS

3/8" (10 MM) MIN DIA

TURNBUCKLE

NEW CONSTRUCTION ONLY.

3/8" (10 MM) MIN DIA INSERTS

IN SLABS OR BEAMS OF

INSERTS FOR NEW CONSTRICTION

EXISTING CONSTRUCTION AND

4" (100 MM) MIN DEPTH

CONCRETE

NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.

MAXIMUM PIPE/TUBING SUPPORT SPACING

TUBING 5 FT

NOM. SIZE

PIPE

THRU (20)

6 8 10

(32)(25) (40)

(65)

(50)

(75)

ADJUSTABLE CLEVIS HANGER

TYPE 43 - SEE SPECIFICATIONS

SADDLE

WELD

1312 14 16

(125)(100)

(150)

(200)

TO 1000 LB. (453 KG) UNIFORM LOAD

TRAPEZE HANGER FOR UP

PROVIDE INSULATION SHIELD

SIDE VIEW

1 5/8" (43 MM) 12 GAGE1" (25 MM) MAX.

STRENGTH INSULATION

PROVIDE HIGH COMPRESSIVE

TYPE 1 - SEE SPECIFICATIONS

ADJUSTABLE CLEVIS HANGER

HANGER ROD

UNDER INSULATION SHIELD

AT HANGER

INSULATION SHIELD

TEMPERATURE PIPE)

REQUIRED FOR LOW

BARRIER TYPE IS

INSULATION (VAPOR

SPACING ON

36" (900 MM) MAX.

BAND

(9 PCF MIN. DENSITY)

HANGER RODS WITH

(8" (200 MM) MIN.)

CHANNEL OR 2"x2"x1/4"

(50x50x8 MM) ANGLE

864 532 2 1/21 1/21 1 1/4IN.

(MM)

(M)

FT.

FT.

(M)

(5.8)(5.2)(4.1) (4.9)(3.7)(3.0) (3.4)(2.7)(2.1)

(4.9)(4.1)(3.7) (4.0)(3.0)(2.4)(1.8)5 FT

THRU 3/4

(2.1) (2.1)

(2.1)

(2.7)

(2.4)

1/2" (15 MM) DIA.

EACH CHANNEL

AND INSERT FOR ALL PIPING

LOCATE VALVE AND TRAP

PRIMER, ABOVE CEILING IN AN

ACCESSIBLE LOCATION

1/2" CONTINUOUS SOFT COPPER

TUBING, (TYPICAL) NO JOINTS

FLOOR

COLD WATER MAIN

ISOLATION VALVE

TRAP PRIMER VALVE

FLOOR DRAIN OR FLOOR SINK, SEE FLOOR

PLANS FOR PRECISE LOCATION

NOTES:

1. ALL FLOOR DRAINS AND FLOOR

SINKS SHALL BE PROVIDED WITH A

TRAP PRIMER.

FAUCET SEE

SPECIFICATIONS

OFFSET WASTE

TRAP PARALLEL TO WALL.

PROVIDE PROTECTIVE TRAP

COVER PER

SPECIFICATIONS.

LOOSE KEY STOP

ESCUTCHEON

FINISHED FLOOR

FOR FIXTURE HEIGHTS SEE ARCHITECTURAL

DRAWINGS

10 3/4"

8"

34"

M

IN

IM

U

M

FLASH VENT WITH 6 LB. LEAD

CAP AND BASE. ROLL CAP 1"

INTO TOP OF VENT. BASE TO BE

2'-0" SQUARE

VENT (SEE PLANS FOR

SIZES, MINIMUM

3-INCHES)

ROOFING

INSULATION

THREADED DRAIN VALVE WITH CAP

CW

REDUCED PRESSURE BACKFLOW ASSEMBLY

WITH STRAINER AND DRAIN CUP.

CONNECT TO EQUIPMENT

ROUTE INDIRECT

WASTE TO LOCAL

FLOOR DRAIN

H W

C W

3/4" 3/4"

3/4"

T H

W

TEST PLUG

NOTE:

INSTALL IN AN ACCESSIBLE

LOCATION.

MIXING VALVE, SET TO DELIVER

105 DEGREES

FLASHING

12" MIN.

DOME STRAINER

FLASHING CLAMP

WITH

GRAVEL STOP

FLASHING

GRAVEL

ROOF

UNDERDECK

CLAMP

DRAIN PIPE

ROOF DRAIN

OUTLET

NO-HUB

CONNECTOR

ISOLATION VALVE (TYPICAL)

3/4"

HWR

SEE PLAN FOR SIZE

HW

BACK TO DOMESTIC HOT

WATER RECIRCULATING PUMP

THERMOSTATIC BALANCE VALVE 3/4"

(REFER TO NOTE 2)

TIE-INTO FIXTURES

CHECK VALVE

NOTES:

1. ALL PLUMBING FIXTURES UTILIZING HOT WATER SHALL BE CONNECTED WITHIN 20' OF THE

DOMESTIC HOT WATER MAIN. RECIRCULATION VALVE ASSEMBLIES SHALL BE AT THE END OF

THE DOMESTIC HOT WATER SERVICE LINE, SEE PLANS.

2. THERMOSTATIC BALANCE VALVE; VALVE CONSTRUCTION - STAINLESS STEEL, THREADED

CONNECTION AND SELF-ACTUATING, OPENING TEMPERATURE - 110°F, CLOSING TEMPERATURE

120°F AND WATER FLOW RANGE(GPM) - 0.2 TO 4.0. THERMOSTATIC BALANCE VALVE SHALL HAVE

BUILT-IN BYPASS WITH MINIMUM FLOW OF 0.2 GPM.

3/4"

3/4"

3/4"

NOT TO SCALE

DOMESTIC WATER BACKFLOW PREVENTER DETAIL

NICKEL

BRONZE

ADJUSTABLE

STRAINER

CEMENT BED

TILE FLOOR

CONCRETE FILL

STRUCTURAL SLAB

FLASHING

CLAMP WITH

WEEP

HOLES

THREADED, CAULKED

OR

NO-HUB CONNECTION

LOOSE GRAVEL

AT WEEP HOLES

3mm to 6mm

SIZE

WATERPROOF

MEMBRANE

PROVIDE A METAL SUPPORT

PLATE WHEN DRAIN IS

INSTALLED IN AN EXISTING

FLOOR - CAULK AROUND

DRAIN PRIOR TO RE-

GROUTING

CLAMP WATERPROOF

MEMBRANE INSIDE OF

DRAIN BODY

CLEAN WEEPS

TYPICAL PIPE HANGERS

OX

MV

OX

MV

PROVIDE LOCKABLE

SERVICE VALVES

UPSTREAM OF ZONE

VALVE BOX

MEDICAL GAS

VALVE BOX

"PATIENT SIDE"

DETAIL NOTES:

1. REFER TO ARCHITECTURAL PLANS FOR

VALVE BOX AND ALARM PANEL LOCATIONS.

SEE ARCHITECTURAL ELEVATIONS FOR

MOUNTING HEIGHTS OF VALVE BOXES AND

ALARM PANELS.

2. REFER TO FLOOR PLANS FOR ROUTING

OF MEDICAL GAS PIPING.

3. REFER TO SCHEDULE FOR PIPE SIZES

TO ZONE VALVE BOX.

FLOOR

CEILING

UPSTREAM

"SOURCE SIDE"

DOWNSTREAM

L

L

3/4"

1"

MEDICAL ZONE VALVE BOX DETAIL

NOT TO SCALE

FIRE STOPPING WALL AND FLOOR DETAIL

P-807

P-755

P-555

3" VTR

CO

3" VTR

FD-C

CO

P-807

P-755

P-555

P-807

P-755

P-555

P-807

P-755

P-555

P-807

P-755

P-555

P-403

P-403

P-807

P-755

P-577

P-807

P-755

P-555

FD-S

CO

P-555

FD-C

3" VTR

2" V

3" VTR

P-807

P-755

P-555

P-807

P-755

P-555

3" V

P-502

2" V

3" V

P-103

P-403

P-528

P-807

P-755

P-555

P-403

P-103

P-807

P-755

P-555

P-807

P-755

P-555

CO

CO

CO

2" SAN

4" SAN

CO

2" SAN CO

FD-C

FD-B

FD-B

FD-B

FD-B

4" SAN

4" SAN

CO

CO

3" SAN 2" SAN

CO

2" SAN

3" VTR

3" SAN

4" SAN

2" V

1 1/2" V

1 1/2" SAN

2" V

1 1/2" V

1 1/2" SAN

4" SAN

4" SAN

1 1/2" SAN

1 1/2" SAN

1 1/2" V

2" V

1 1/2" V

1 1/2" SAN

1 1/2" SAN

1 1/2" V

FD-S

4" SAN

1 1/2" V

1 1/2" SAN

4" SAN

1 1/2" SAN

1 1/2" V

4" SAN

4" SAN

4" SAN

CO

2" SAN

2" SAN

1 1/2" SAN

1 1/2" SAN

1 1/2" V

1 1/2" V

3" V

1 1/2" V

1 1/2" SAN

1 1/2" V

1 1/2" SAN

4" SAN

1 1/2" SAN

4" SAN

X - 4" SAN

2" V

1 1/2" V1 1/2" V

1 1/2" V

1 1/2" SAN

3" SAN

2" V

1 1/2" V

1 1/2" SAN

2" V

1 1/2" SAN

4" SAN

4" SAN

4" SAN

CO

4" SAN

1 1/2" SAN

1 1/2" V

2" V

4" SAN

4" SAN

3" V

CO

3" V

1 1/2" V

CO

CO

1 1/2" V

1 1/2" V

4" SAN

4" SAN

2" V

3" V

3" V

4" SAN

4" SAN

CO

CO

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:4

:1

A

M

0-P-901

PHASE 1 PLUMBING ISOMETRICS Renovate Research K-Wing 541-20-104

1/20/2022 LDH SIC

NOT TO SCALE

PHASE 1 SANITARY ISOMETRIC 1

# CODED NOTES

1-1/2" SANITARY PIPING SERVING SINK IN FUME HOOD.

1-1/2" VENT PIPING SERVING SINK IN FUME HOOD.

INSTALL 3" VENT DOWN TO FIRST FLOOR CEILING SPACE. CONNECT TO FIRST FLOOR VENT DURING

PHASE 2 CONSTRUCTION.

NEW SANITARY PIPING FOR ROOF PENTHOUSE FLOOR DRAINS TO BE INSTALLED UNDER PHASE 2.

P-555

P-502

P-555

P-505

P-403

P-103

P-403

P-528

P-103

P-403

P-403

P-403

P-403

P-555

P-528

P-403

P-403

P-403P-403

FD-S

FD-C

FD-S

FD-C

FD-SFD-C

2" V

FD-C

FD-C

FD-C

FD-C

2" V

CONNECT TO 3" V

INSTALLED UNDER

PHASE 1

2" V

CO

P-528

P-103

P-403

P-103

P-403

EXISTING SINK

IN K119

CONFERENCE

ROOM

CO

CO

CO

4" SANITARY DOWN

TO SUB-BASEMENT

CO

CO

CO

4" SAN

2" SAN

CO

CO

CO

CO

2" SAN

4" SAN

CO

4" SAN

FD-B

FD-B

FD-B

X - 4" SAN

X - 4" SAN

X - 2" SAN

X - 4" SAN

X - 4" SAN

X - 4" SAN

X - 4" SAN

X - 4" SANX-FD-B

X-FD-B

X-FD-B

4" SAN

2" SAN

FD-C

P-809

FD-C

TYP. OF 4

2" SAN

2" SAN

1 1/2" V

P-708

FD-C

CO

C O

4" SAN

4" SAN

4" SAN 4" SAN

4" SAN

1 1/2" SAN

2" V

1 1/2" V

P-809

2" SAN 4" SAN

4" SAN

4" SAN

4" SAN

CO

1 1/2" SAN

4" SAN

1 1/2" V 1 1/2" V

P-403

4" SAN

2" SAN 2" SAN

2" V

2" V1 1/2" V

4" SAN

P-809

TYP. OF 4

2" SAN

2" SAN

2" SAN

3" SAN

3" SAN

1 1/2" V

1 1/2" V

1 1/2" V

2" V

1 1/2" V

3" V

2" V 1 1/2" V

3" V 1 1/2" V

1 1/2" V

1 1/2" SAN

P-708

P-403

FD-C

4" SAN

1 1/2" SAN

1 1/2" SAN

1 1/2" SAN

P-708

P-809

2" V

4" SAN

4" SAN

4" SANP-809

P-809

P-809

P-809

P-809

P-809

1 1/2" SAN

3" SAN

1 1/2" SAN

2" SAN

4" SAN

4" SAN

4" SAN

1 1/2" SAN

4" SAN

2" SAN

4" SAN

FD-C

2" V

2" V

2" V

4" SAN

4" SAN

2" SAN

1 1/2" SAN

4" SAN

1 1/2" SAN

2" V

3" V

3" V

2" V

1 1/2" V

2" V

4" SAN

4" SAN

2" SAN

CO

CO

2" V

1 1/2" V

2" V

1 1/2" V

3" V

CO1 1/2" SAN

1 1/2" V

4" SAN

2" V

1 1/2" SAN

1 1/2" V

2" V

1 1/2" V

X - 2" SAN

X - 1 1/2" V

X-FD-B

1 1/2" V

2" SAN

4" SAN

2" V

2" V

1 1/2" V

1 1/2" V

2" V

4" SAN

4" SAN

2" SAN

2" SAN

1 1/2" SAN

P-809

CO

2" SAN

CO

CO

1 1/2" V

1 1/2" V

1 1/2" V

2" V

1 1/2" V

CO

CO

CO

X - 3" V 2" V

FD-T

FD-T

2" V

4" SAN

2" V

4" SAN

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:4

:3

A

M

0-P-902

PHASE 2 PLUMBING ISOMETRIC Renovate Research K-Wing 541-20-104

1/20/2022 LDH JTP

NOT TO SCALE 1

PHASE 2 SANITARY ISOMETRIC

DN

DNDN

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

CAP

X R

-S A

N

X R

-S A

N X

R -S

A N

X R

-S A

N

X R

-S A

N

XR-SAN

CAP

Pharmacology

K109

Culture Tissue

K105

Prefab Control Temp.

Room

K103

Tissue Culture

K101B

Prefab.

Control Temp.

Room

K104A

Stair 24

1S24

Stair 21

1S21

Closet

K111A

Men's Toilet

K111

Acos. & Conf.

K113

Secretary Clergy

K115

Res.

Chemist

K102A

Storage

K118

Corridor

K100B

Janitor

K120

Admin Office

K121

Investigator

K108B

Office

K114B

Serv.

Lobby

K100

F.A.C.

K105A

Conference Room

K119 Elec.

Closet

K122B

Tele.

Closet

K122A

Conference Study

K122

Corridor

K100C

Dermatology

K114

Hormone Studies

K101

Hormone Studies

K102

Corridor

K100A

Sect'y & Clerk

K117

Incubating Equipment

Room

K101A

Dermatology

K104 Office

K104B

Lab

K107

Investigator

K109A

Office

K107A

Pharmacology

K106 Pharmacology

K108

High Pressure

Liquid Chromatography

K110

Women's Toilet

K112

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:5

A

M

1-PD-103

PHASE 1 - FIRST FLOOR PLUMBING

DEMOLITION PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 1 - FIRST FLOOR PLUMBING DEMOLITION

PLAN 1N

# CODED NOTES

REMOVE EXISTING SANITARY STACK FROM FLOOR-TO-FLOOR AND REPLACE WITH NEW. REPLACEMENT SHALL BE SCHEDULED DURING OFF-HOURS AND SHUTDOWN SHALL BE MINIMIZED IN ORDER TO AVOID

DISRUPTION. COORDINATE WITH VA COR.

REMOVE SANITARY BACK TO ACTIVE MAIN AND CAP. FIELD VERIFY EXACT ROUTE.

RELOCATE EXISTING 4" ST AS REQUIRED TO ACCOMMODATE 2ND FLOOR RENOVATION.

REMOVE EXISTING STORM IN APPROXIMATE LOCATION FIELD VERIFY EXACT ROUTING.

GENERAL NOTES

A. WORK ABOVE FIRST FLOOR CEILING DURING PHASE 1 SHALL BE COMPLETED DURING OFF-HOURS.

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

XR-V

XR-V

VENT

XR-VTR

XR-VTR

XR-VTR

XR-VTR

XR-VTR

X-VTR

XR-VTR

XR-VTR

XR-VTR

XR-VTR

XR-VTR

XR-SAN SERVING

PENTHOUSE

CAP

X R

-V

XR-SAN

Stair 24

2S24

Women

K214

Men

K213 Elect.

K214A

Temp Control

K208

Comp.

K201A

Cancer Research

K212

Office

K218A

Storage

K205C

Corridor

K200E

Office

K217A

Closet

K215B

Research Laboratory

K218

Corridor

K200B

Service Elevator Lobby

K200

Cooler

K204

Derm Laboratory

K211

Office

K211A

Comm.

K223

Corridor

K200A

Office

K220A

Office

K219A

Research Laboratory

K219

Mech

K224

Office

K215A

Research Cancer

K217

Research Optometry

K215

Endo Laboratory

K201

Research Surgery

K216

Storage

K216A

Tissue Culture

K202

Research Vascular

K203

Office

K205B

Office

K203A

Stair 21

2S21

Closet

K206B

Corridor

K200C

Office

K207A

Derm Laboratory

K207

Derm Laboratory

K210

Office

K206A

Endo Laboratory

K206

Elect.

K222

Research Laboratory

K220

Motion Studies

Lab

K205A

Research Laboratory

K205

Corridor

K200D

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:0

A

M

1-PD-104

PHASE 1 - SECOND FLOOR PLUMBING

DEMOLITION PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 1 - SECOND FLOOR PLUMBING DEMOLITION

PLAN 1N

# CODED NOTES

REMOVE EXISTING SINK/LAVATORY COMPLETELY. REMOVE SANITARY AND VENT BACK TO ACTIVE MAINS. REMOVE DOMESTIC WATER TO BELOW SLAB AND CAP. DOMESTIC WATER SHALL BE REMOVED

FURTHER AS PART OF FIRST FLOOR DEMOLITION.

REMOVE EXISTING WATER CLOSET COMPLETELY. REMOVE SANITARY AND VENT BACK TO ACTIVE

MAINS. REMOVE DOMESTIC WATER TO BELOW SLAB AND CAP. DOMESTIC WATER SHALL BE REMOVED

FURTHER AS PART OF FIRST FLOOR DEMOLITION.

REMOVE EXISTING URINAL COMPLETELY. REMOVE SANITARY AND VENT BACK TO ACTIVE MAINS.

REMOVE DOMESTIC WATER TO BELOW SLAB AND CAP. DOMESTIC WATER SHALL BE REMOVED

FURTHER AS PART OF FIRST FLOOR DEMOLITION.

REMOVE EXISTING EYEWASH/SHOWER FIXTURE COMPLETELY. REMOVE SANITARY AND VENT BACK TO ACTIVE MAINS. REMOVE DOMESTIC WATER TO BELOW SLAB AND CAP. DOMESTIC WATER SHALL BE

REMOVED FURTHER AS PART OF FIRST FLOOR DEMOLITION.

REMOVE EXISTING MOP SINK COMPLETELY. REMOVE SANITARY, VENT, COLD WATER, AND HOT WATER

BACK TO ACTIVE MAINS AND CAP.

REMOVE ALL PIPING, DRAINS, ETC. SERVING EXISTING COLD ROOM COMPLETELY.

REMOVE EXISTING VENT BACK TO ACTIVE MAIN AND CAP. IF VENT EXITS TO VTR, REMOVE VTR AND

PATCH ROOF TO MATCH.

RELOCATE EXISTING 4" STORM AS REQUIRED TO ACCOMMODATE RENOVATIONS.

REMOVE EXISTING STORM LEADER COMPLETELY.

REMOVE EXISTING DRINKING FOUNTAIN COMPLETELY. REMOVE SANITARY AND VENT BACK TO ACTIVE MAINS. REMOVE DOMESTIC WATER TO BELOW SLAB AND CAP. DOMESTIC WATER SHALL BE REMOVED

FURTHER AS PART OF FIRST FLOOR DEMOLITION.

REMOVE EXISTING WATER LINE BACK TO ACTIVE MAIN AND CAP

GENERAL NOTES

SECOND FLOOR FIXTURES ARE SERVED BY DOMESTIC WATER MAINS ON FIRST FLOOR. REMOVE PIPING

TO BELOW SLAB. PATCH SLAB. MAINS TO BE REMOVED FURTHER AS PART OF PHASE 2.

ALL WORK ON FIRST FLOOR SHALL BE CLOSELY COORDINATED WITH VA COR.

ALL EXISTING VENTS SERVING BASEMENT AND FIRST FLOOR SHALL REMAIN ACTIVE. RELOCATE VENT

MAINS AS REQUIRED TO ACCOMMODATE RENOVATIONS.

REMOVE ALL UTILITIES SERVING FUME HOODS AND OTHER LAB EQUIPMENT.

EXISTING ACTIVE STORM PIPING SHALL BE RELOCATED AS NECESSARY TO ACCOMMODATE ALL NEW

SYSTEMS INSTALLATIONS

A.

B.

C.

D.

E.

H G F C B

E DG1

A.1

10.9

10.1

9.5

9.1

7.9

1.2

7.6

10.8

XR-VTR

X-RD

XR-VTRXR-VTR

X-VTR

XR-VTR

XR-VTR

XR-VTR

XR-VTR

XR-VTR

XR-RD

X-RD

XR-VTR

X-ST

XR-VTR

XR - 3/4"

XR-VTR

XR-VTR

XR-VTR

XR-VTR

XR-VTR

XR-VTR XR-VTR

1 TYP.1 TYP.

X-STORM - 3"

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:1

A

M

1-PD-105

PHASE 1 - ROOF/PENTHOUSE PLUMBING

DEMOLITION PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 1 - ROOF/PENTHOUSE PLUMBING

DEMOLITION PLAN 1

# CODED NOTES

REMOVE EXISTING FLOOR DRAIN COMPLETELY.

REMOVE EXISTING ROOF DRAIN.

REMOVE CW BACK TO ACTIVE MAIN AND CAP.

REMOVE EXISTING HOSE BIB COMPLETELY.

GENERAL NOTES

A. CONTRACTOR SHALL REMOVE EXISTING VTR'S SERVING FIRST AND SECOND FLOORS. VTR'S SERVING

BASEMENT AND ACTIVE SPACES SHALL REMAIN.

N

H G F C BE DG1 A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

X R

-L V X R

-L G

X R

-L A

X R

-L V

X R

-L G

X R

-L A

XR-LV

XR-LG

XR-LA

Stair 24

2S24

Women

K214

Men

K213

Elect.

K214A

Temp Control

K208

Comp.

K201A

Cancer Research

K212

Office

K218A

Storage

K205C

Office

K217A

Closet

K215B

Research Laboratory

K218

Corridor

K200B

Service Elevator Lobby

K200

Cooler

K204

Derm Laboratory

K211

Office

K211A

Comm.

K223

Corridor

K200A

Office

K220A

Office

K219A

Research Laboratory

K219

Mech

K224

Office

K215A

Research Cancer

K217

Research Optometry

K215

Endo Laboratory

K201

Research Surgery

K216

Storage

K216A

Tissue Culture

K202

Research Vascular

K203

Office

K205B

Office

K203A

Stair 21

2S21

Closet

K206B

Corridor

K200C

Office

K207A

Derm Laboratory

K207

Derm Laboratory

K210

Office

K206A

Endo Laboratory

K206

Elect.

K222

Research Laboratory

K220

Motion Studies

Lab

K205A

Research Laboratory

K205

Corridor

K200D

74490

L.D. HENDRIX, JR

GN

S S

A

I ON EL

T

F EGE

P R O

R

SI NRE I

E E R

D

E

AT

S

ET

O

OI

HO

F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID ISSUE

FULLY SPRINKLERED

Louis Stokes Cleveland

VA Medical Center

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

CLEVELAND, OHIO

19074

Consulting Engineers

BARBER & HOFFMAN, INC.

2217 East 9th Street, Suite 350 Cleveland, OH 44115-1257 216-875-0100/ (F) 216-875-0111 barberhoffman.com

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440) 546-9696

FAX: (440) 546-9699

C R e v it L o c a l F ile s \1

F

F H

C F

R

C h ri s to p h e r.

P

.C a m p b e ll.

rv t

/2

/2

:5

:2

A

M

1-PD-114

PHASE 1 - SECOND FLOOR

LABORATORY GAS AND VACUUM

DEMOLITION PLAN

Renovate Research K-Wing 541-20-104

1/20/2022 LDH IMF

0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'

1/8" = 1'-0"

PHASE 1 - SECOND FLOOR LABORATORY GAS AND

VACUUM DEMOLITION PLAN 1N

GENERAL NOTES

A. NOT ALL PIPING TO LAB BENCHES, HOODS, ETC IS ILLUSTRATED. FIELD VERIFY EXISTING CONDITIONS.

B. ALL EXISTING LA, LV, G PIPING SERVING SECOND FLOOR SHALL BE REMOVED COMPLETELY.

# CODED NOTES#

REMOVE EXISTING LA,LV,AND GAS PIPING BACK TO ACTIVE MAINS IN BASEMENT AND CAP.

REMOVE EXISTING OXYGEN VALVE.

REMOVE ALL OXYGEN PIPING BACK TO ACTIVE MAINS AND CAP.

H G F C B

E DG1

A.1

10.9

10.1

9.5

9.1

7.9

1.2

CC1

7.6

10.8

X - 1 1/2" DEI

X - 1 1/2" DEIR

CAP CAP

CAP

CAP

CAP

CAP

Hazardous Waste

BF469

Electrical Vault

BF458

Stair 21

BS21

Hazardous Waste

BF424

Quarantine Ward

BF465

Animal Ward-2

BF462-2

Security-2

BF468A-2

Procedure Lab

BF464B

Procedure Lab

BF464A

Ve…

This is the start of the file's text. The full file is on GovTribe.