RVA1033004_Mechanical.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24623B0024
About this file
This is a solicitation for renovating the old dialysis area at the Richmond VA Medical Center. The solicitation seeks mechanical, electrical, and plumbing (MEP) construction services including installation of new HVAC equipment, ductwork, piping, controls, and associated construction. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6. The response due date is not provided. Construction is to begin upon award. Pricing is to be provided using the Standard Form 1442 lump sum pricing format. The solicitation is unrestricted and open to all responsible sources.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BID OPENING Abstract 36C24623B0024.pdf | ||
| BID OPENING Attendance Log 36C24623B0024.pdf | ||
| SITE VISIT Attendance Log 36C24623B0024.pdf | ||
| 36C24623B0024 0006.docx | DOCX document | |
| 36C24623B0024 0005.docx | DOCX document | |
| 36C24623B0024 0004.docx | DOCX document | |
| 36C24623B0024 0003.docx | DOCX document | |
| 36C24623B0024 0002.docx | DOCX document | |
| 36C24623B0024 0001.docx | DOCX document | |
| Attachment A - Itemized Schedule of Values Cost Breakdown.xlsx | XLSX spreadsheet | |
| INSTRUCTIONS TO BIDDERS.pdf | ||
| 36C24623B0024_1.docx | DOCX document | |
| RVA1033004_Plumbing-revised.pdf | ||
| RVA1033004_Life Safety Set.pdf | ||
| RVA1033004_Architecture.pdf | ||
| RVA1033004_Electrical.pdf | ||
| RVA1033004_Telecom Set.pdf | ||
| Specifications Vol 1.pdf | ||
| Specifications Vol 2.pdf | ||
| RVA1033.004_PL_Addendum_1_2023-03-24.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET NAMING CONVENTION
M-001A
2 DIGIT SEQUENTIAL # (01-99)
(FIRST DIGIT INDICATES PLAN
TYPE. SECOND DIGIT INDICATES
FLOOR)
1 DIGIT SHEET TYPE DESIGNATOR
0 - GENERAL
1 - PLANS
2 - ELEVATIONS
3 - SECTIONS
4 - ENLARGED PLANS
5 - DETAILS
6 - SCHEDULES AND DIAGRAMS
7 - VARIES
8 - VARIES
9 - 3D VIEWS (ISO, PERSPECTIVES)
2 DIGIT DISCIPLINE
DESIGNATOR
(IF ONLY ONE LETTER IS
USED, THE SECOND
LETTER IS REPLACED
WITH A DASH "-" AS A
PLACEHOLDER)**
1 DIGIT AREA
DESIGNATOR
(AREA DESIGNATOR
ONLY USED WHEN
PLANS ARE SUBDIVIDED
INTO AREAS.)
GENERAL MECHANICAL NOTES
1. INSTALLATION OF HVAC WORK SHALL BE COORDINATED WITH OTHER TRADES BEFORE ANY INSTALLATION IS MADE. DUCTWORK SHOWN ON PLANS IS SCHEMATIC. DUCTWORK SHALL BE INSTALLED TIGHT TO STRUCTURE. ALL TRANSITIONS, ELBOWS, ETC.
REQUIRED TO AVOID CONFLICTS & MAXIMIZE CEILING HEIGHTS. EQUIPMENT, PIPING OR DUCTWORK INTERFERING WITH OTHER
TRADES SHALL BE RELOCATED AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER.
2. COORDINATE MECHANICAL AND ELECTRICAL SUCH THAT MECHANICAL PIPING, DUCTWORK AND EQUIPMENT IS NOT LOCATED
OVER OR ABOVE ANY ELECTRICAL, COMMUNICATIONS, OR DATA EQUIPMENT.
3. AT START OF CONSTRUCTION PREPARE TYPED LISTS OF EQUIPMENT THAT ARE SUPPLIED REQUIRING ELECTRICAL WORK, AND
SEND LISTS TO THE ELECTRICAL CONTRACTOR FOR REVIEW AND COORDINATION.
4. WRITTEN DIMENSIONS ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
5. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S APPROVED CLEARANCE, UNIFIED FACILITIES
CRITERIA, AND INTERNATIONAL BUILDING CODE / INTERNATIONAL MECHANICAL CODE.
6. INSTALLATION OF EQUIPMENT SHALL PERMIT ACCESSIBILITY FOR SERVICE AND/OR REPLACEMENT WITHOUT NECESSITATING
REMOVAL OR MODIFICATION TO OTHER PIPING, WIRING, OR EQUIPMENT.
7. CEILING-MOUNTED EQUIPMENT SHALL BE INSTALLED IN SUCH A MANNER THAT LIGHTS, PIPING, DUCTWORK, ETC., DO NOT
BLOCK ACCESS TO EQUIPMENT AND RELATED ACCESSORIES.
8. COORDINATE WALL, FLOOR AND ROOF PENETRATIONS WITH THE GENERAL CONTRACTOR.
9. CAULK WITH SILICONE ALL GAPS BETWEEN WALL, CEILING AND FLOOR OPENINGS AND HVAC EQUIPMENT PENETRATIONS.
PATCH LARGE GAPS BEFORE CAULKING IS APPLIED. [REFER TO SPECIFICATION SECTION 23 00 00 - AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS, SUBSECTION 2.1.2].
10. SUPPLEMENTAL STEEL MEMBERS REQUIRED TO SUPPORT HVAC EQUIPMENT FROM MAIN STRUCTURE SHALL BE PROVIDED BY THE HVAC CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. REFER TO STRUCTURAL DRAWINGS AND SPECIFICATIONS FOR CONSTRUCTION TYPES. PROCURE AND INSTALL UPON APPROVAL FROM [CONTRACTING OFFICER] [GENERAL CONTRACTOR] [ARCHITECT]. PROVIDE STRUCTURAL STEEL SUPPORT SUBMITTAL TO ENGINEER OF RECORD FOR REVIEW.
11. DUCTWORK AIR DISTRIBUTION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS AND THE PRESSURE
CLASSIFICATION OF EACH INDIVIDUAL DUCTWORK SYSTEM.
12. VOLUME DAMPERS SHALL BE PROVIDED AT EACH NEW MAIN BRANCH TAKE-OFF AND IN SUCH OTHER LOCATIONS WHERE
REQUIRED TO PROPERLY BALANCE THE SYSTEM.
13. INSTRUMENT TEST HOLES SHALL BE PROVIDED IN AIR DISTRIBUTION SYSTEMS WHEREVER VOLUME DAMPERS ARE INSTALLED.
14. SQUARE ELBOWS SHALL ONLY BE USED WHERE SPACE LIMITATIONS PREVENT USE OF 1.5 RADIUS ELBOW AND ONLY UPON APPROVAL OF [CONTRACTING OFFICER] [GENERAL CONTRACTOR] [ARCHITECT]. PROVIDE TURNING VANES IN ALL 45° AND 90° SQUARE ELBOWS. TURNING VANES SHALL BE SINGLE THICKNESS TYPE WITHOUT RAILING EDGE. TURNING VANES LONGER THAN
36 INCHES SHALL BE DOUBLE THICKNESS TYPE.
15. DUCTWORK RUNOUTS TO AIR DISTRIBUTION DEVICES SHALL BE SAME DIAMETER AS AIR DISTRIBUTION DEVICE INLET
CONNECTION UNLESS OTHERWISE NOTED ON THE DRAWINGS.
16. FLEXIBLE DUCTWORK RUNOUTS FROM BRANCH DUCTS TO AIR DISTRIBUTION DEVICES SHALL NOT EXCEED 5 FEET IN LENGTH.
BENDS IN FLEXIBLE DUCTWORK SHALL NOT EXCEED A MAXIMUM OF 45 DEGREE CHANGE OF DIRECTION AND BE SUPPORTED SUCH THAT THE BEND RADIUS IS NOT RESTRICTIVE TO AIR FLOW THROUGH THE DUCT. FLEXIBLE DUCTWORK SHALL NOT BE
CRUSHED OR DISTORTED IN ITS FINAL CONFIGURATION.
17. ROUND DUCTWORK CONNECTIONS BETWEEN MAIN DUCT AND TERMINAL UNITS SHALL BE RIGID DUCT OF THE SAME DIAMETER
AS TERMINAL UNIT INLET CONNECTION UNLESS OTHERWISE NOTED ON THE DRAWINGS.
18. PROVIDE SHEETMETAL TRANSITIONS AT AIR HANDLING UNITS, HEAT PUMP UNITS, FANS, AND OTHER SIMILAR HVAC EQUIPMENT.
TRANSITION TO FULL SIZE OF CONNECTION ON UNIT. FLEXIBLE DUCT CONNECTORS SHALL BE USED ON FINAL CONNECTION TO
AIR HANDLING EQUIPMENT.
19. DIMENSIONS SHOWN FOR DIFFUSERS AND GRILLES ARE NECK DIMENSIONS.
20. EXACT LOCATION OF CEILING DIFFUSERS, GRILLES AND REGISTERS SHALL BE DETERMINED BY ARCHITECTURAL REFLECTED
CEILING PLAN.
21. PROVIDE ACCESS PANELS TO ACCESS DAMPERS, EQUIPMENT, AND VALVES LOCATED ABOVE HARD CEILINGS OR IN WALLS.
ACTUAL LOCATIONS SHALL BE FIELD DETERMINED.
22. EXACT LOCATIONS OF THERMOSTATS SHALL BE COORDINATED WITH FINAL LOCATIONS OF WALL-MOUNTED ARCHITECTURAL
AND ELECTRICAL EQUIPMENT. MOUNT THERMOSTATS MINIMUM 48" AFF.
23. SUPPLY, RETURN, AND OUTDOOR AIR DUCTWORK SHALL BE INSULATED TO MEET OR EXCEED ASHRAE 90.1. EXTERIOR SUPPLY
AND RETURN AIR DUCTWORK SHALL BE PROVIDED WITH WEATHER-PROOF COVER.
24. SIZE REFRIGERANT LINES PER MANUFACTURER'S INSTRUCTIONS FOR ACTUAL LINE LENGTHS AND EQUIPMENT ELEVATIONS INSTALLED. USE OF HCFC AND CFC REFRIGERANTS IS PROHIBITED. EXTERIOR REFRIGERANT LINES SHALL BE INSULATED AND
HAVE ALUMINUM JACKETING.
25. COORDINATE LOCATIONS OF CONDENSATE DRAIN PIPING. PROVIDE CONDENSATE PUMPS AS REQUIRED WHERE SUFFICIENT SLOPE IS NOT AVAILABLE FOR STANDARD GRAVITY DRAIN, WITH OVERRIDE SWITCH TO POWER DOWN THE ASSOCIATED AIR HANDLING EQUIPMENT IN CASE OF CONDENSATE PUMP FAILURE. CONDENSATE DRAIN LINE SHALL SLOPE DOWN TOWARDS DISCHARGE LOCATION AT A MINIMUM OF 1/8" PER LINEAR FOOT. INSULATE INDOOR CONDENSATE PIPING WITH 3/4" CLOSED CELL
FOAM INSULATION.
26. PROVIDE SUPPORTS FOR PIPING AND DUCTWORK IN ACCORDANCE WITH SPECIFICATIONS.
27. PROVIDE A MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOP ON ALL DUCTWORK AND PIPING SYSTEMS
CROSSING BUILDING EXPANSION JOINTS.
28. PROVIDE EXPANSION LOOPS OR APPROVED FLEXIBLE PIPE EXPANSION DEVICES FOR PIPING SYSTEMS WITH OPERATING TEMPERATURES ABOVE 70°F OR BELOW 50°F. PIPE SUPPORTS FOR PIPING SYSTEMS WITH EXPANSION DEVICES OR EXPANSION
LOOPS SHALL HAVE ROLLER SUPPORTS.
29. PROVIDE AUTOMATIC AIR VENTS AT HIGH POINTS OF HYDRONIC PIPING SYSTEMS. PROVIDE DRAIN VALVES AT THE LOW POINTS
IN HYDRONIC PIPING SYSTEMS FOR DRAINAGE.
30. PROVIDE SHUT-OFF VALVES AND FLEXIBLE CONNECTIONS AT PIPE CONNECTIONS TO HVAC EQUIPMENT.
31. FOR WALL, FLOOR, AND SLAB PENETRATIONS SEAL AND PATCH ALL UNUSED PENETRATION SPACE TO MATCH EXISTING OR AS
SHOWN ON MECHANICAL DETAILS SHEET.
32. INSTALL EXPOSED CONTROL WIRING IN CONDUIT. SEE DIVISION 26 SPECIFICATIONS FOR REQUIREMENTS.
33. BRANCH VALVES AND DRAINS SHALL BE PROVIDED TO ENABLE ISOLATING A SECTION FOR MAINTENANCE WITHOUT SHUTTING
DOWN ENTIRE SYSTEM.
34. MANUFACTURER NAME AND MODEL NUMBERS ARE BASIS OF DESIGN AND ARE SHOWN FOR INFORMATION ONLY. REFER TO SPECIFICATIONs FOR COMPLETE REQUIREMENTS.
35. PIPING INSULATION SHALL BE PROVIDED ON ALL PIPING SYSTEMS INCLUDING (BUT NOT LIMITED TO) CHILLED WATER, HEATING HOT WATER, CONDENSER WATER, REFRIGERANT, AND CONDENSATE DRAIN IN ACCORDANCE WITH ASHRAE 90.1.
36. SPECIFICATIONS TAKE PRECEDENCE OVER DRAWINGS. HOWEVER, ITEMS SHOWN ON DRAWING BUT NOT IN THE SPECIFICATIONS ARE REQUIRED WITHIN THE PROJECT SCOPE. IN ADDITION, SPECIFIC ITEMS SHOWN ON THE DRAWINGS TAKE PRECEDENCE
OVER SPECIFICATIONS IN CASES WHERE THE SPECIFICATION HAS OPTIONS.
37. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S APPROVED PUBLISHED LITERATURE.
38. DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.
39. EXPOSED DUCTWORK, WITH THE EXCEPTION OF DUCTWORK IN MECHANICAL ROOMS SHALL BE DOUBLE-WALL, SPIRAL
DUCTWORK WITH COATING.
40. IF ASBESTOS IS FOUND, STOP WORK IMMEDIATELY AND NOTIFY OWNER AND GENERAL CONTRACTOR. OWNER IS RESPONSIBLE
FOR ABATEMENT OF ASBESTOS.
41. NOT ALL MECHANICAL ABBREVIATIONS SHOWN WILL BE USED FOR THIS PROJECT.
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
MECHANICAL GENERAL NOTES AND
DESIGN CRITERIA
M-001
-2
M -0
/1
/1
.p d f
HVAC DESIGN CRITERIA
PROJECT LOCATION: WEATHER STATION,
STATE
LATITUDE: 37.18 N
ELEVATION: 194 FT.
STANDARD DESIGN CONDITIONS
WINTER DESIGN DRY BULB (99.0%): 19.3 °F
SUMMER DESIGN DRY BULB (1.0%): 94.6 °F
SUMMER DESIGN WET BULB (1.0%): 76.4 °F
INDOOR DESIGN CONDITIONS
SPACE CATEGORY
COOLING HEATING
OCC.
DRY
BULB
(°F)
UNOCC.
DRY
BULB
(°F)
OCC.
DP
(°F)
OCC.
DRY
BULB
(°F)
UNOCC.
DRY
BULB
(°F)
AMB. +
[10°F]
AMB. +
[10°F]
N / A 55 55
ADMINISTRATION SPACES 75 85 57.9 68 55
COMM ROOMS 75 75 62.5 40 40
ENTRANCE VESTIBULES N / A N / A N / A 55 40
STORAGE 78 85 57.9 68 55
NOTES:
1. EXISTING EQUIPMENT IS SHOWN WITH THIN LINEWORK.
2. DEMOLISHED EQUIPMENT IS SHOWN WITH BOLD LINEWORK,
DASHED, AND HATCHED.
3. NEW OR RELOCATED EQUIPMENT IS SHOWN WITH BOLD
LINEWORK.
4. BELOW IS AN EXAMPLE OF EACH:
EXISTING EQUIPMENT
EQUIPMENT TO BE DEMOLISHED
NEW OR RELOCATED EQUIPMENT
GENERAL MECHANICAL ABBREVIATIONS
@ AT
& AND
AFF ABOVE FINISHED FLOOR
A/C ABOVE CEILING
AC AIR CONDITIONER
AD AUTOMATIC DAMPER
ADJ ADJUSTABLE
AMB AMBIENT
ARCH ARCHITECT, ARCHITECTURAL
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATING, AND AIR CONDITIONING
ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
AUX AUXILIARY
BD BACKDRAFT DAMPER
BLDG BUILDING
BOD BOTTOM OF DUCT
B/F BELOW FLOOR
B/S BELOW SLAB
BTU, BTUH BRITISH THERMAL UNITS, BTUs PER HOUR
CD CONDENSATE DRAIN
CFM CUBIC FEET PER MINUTE
CLG COOLING
CO2 CARBON DIOXIDE
CONN CONNECT, CONNECTING, CONNECTION
CONT CONTINUED
COP COEFFICIENT OF PERFORMANCE
COR CONTRACTING OFFICER'S (OWNER'S)
REPRESENTATIVE
CU CONDENSING UNIT
D DEPTH
DB, Tdb DRY BULB (TEMPERATURE) dBA DECIBELS
DDC DIRECT DIGITAL CONTROLS
DEG. F (°F) DEGREES FAHRENHEIT
DIA DIAMETER
DIV DIVISION
DN DOWN
DP, PD DIFFERENTIAL PRESSURE, PRESSURE DROP
DSCU DUCTLESS SPLIT CONDENSING UNIT
DSS DUCTLESS SPLIT SYSTEM (INDOOR UNIT)
DWG DRAWING
DX DIRECT EXPANSION
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
ELEC ELECTRICAL
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXT EXTERIOR
EXH EXHAUST
EXST, (E) EXISTING
FD FIRE DAMPER
FFE FINISHED FLOOR ELEVATION
FLA FULL LOAD AMPS
FPM FEET PER MINUTE
FSD FIRE SMOKE DAMPER
FT FOOT, FEET
FT WG FEET WATER GAUGE
GA GAGE
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
H HEIGHT
HR HOUR
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HZ HERTZ
IMC INTERNATIONAL MECHANICAL CODE
IN INCH, INCHES
IN WC INCHES WATER COLUMN
IN WG INCHES WATER GAUGE
IPLV INTEGRATED PART LOAD VALUE
KW KILOWATTS
L LENGTH, LOUVER (WALL)
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LBF/IN2 POUNDS FORCE PER SQUARE INCH
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH 1000 BRITISH THERMAL UNITS
MCA MINIMUM CIRCUIT AMPACITY
MERV MINIMUM EFFICIENCY REPORTING VALUE
MECH MECHANICAL
MFR, MFG MANUFACTURER, MANUFACTURING
MIN MINIMUM
MOCP, MOP MAXIMUM OVER CURRENT PROTECTION
MOD MOTOR OPERATED DAMPER
MTD MOUNTED
MVD MANUAL VOLUME DAMPER
NC NOISE CRITERIA
N.C. NORMALLY CLOSED
NO. NUMBER
N.O. NORMALLY OPEN
NPLV NET PART LOAD VALUE
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DAMPER
PD PRESSURE DROP
PH PHASE
PLBG PLUMBING
PPM PARTS PER MILLION
PRV PRESSURE RELIEF VALVE
QTY QUANTITY
RA RETURN AIR
RG RETURN GRILLE
RH RELATIVE HUMIDITY, ROOF HOOD
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID
RM ROOM
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
SA SUPPLY AIR
SD SMOKE DAMPER, SMOKE DETECTOR
SEER SEASONAL ENERGY EFFICIENCY RATIO
SF SUPPLY FAN
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTOR'S NATIONAL ASSOCIATION
SP STATIC PRESSURE
SS STAINLESS STEEL
TSTAT THERMOSTAT
TEMP TEMPERATURE
TYP TYPICAL
UL UNDERWRITER'S LABORATORY
V VOLTAGE, VOLTS
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VELO VELOCITY
W WATT(S)
W/ WITH
W/O WITHOUT
WB, Twb WET BULB (TEMPERATURE)
WD WIDE, WIDTH
WMS WIRE MESH SCREEN
AIR DISTRIBUTION DEVICE TAGS
DIFFUSER TYPE
A
400 AIRFLOW (CFM), "PLENUM", OR "TRANSFER"
A1
M-501
PLAN NORTH
TRUE
NORTH
DRAWING REFERENCE KEY
REFER TO
DETAIL NUMBER
SHEET NUMBER OF DETAIL
RE:A1/M-501
NORTH ARROW
A CONTROL WIRING
ROUND
MISCELLANEOUS LEGENDPIPING LEGEND
EXPANSION JOINT
FLEXIBLE CONNECTION
CLEANOUT
WATER METER
FLOOR CLEANOUT
THERMOMETER
PRESSURE REDUCING VALVE
MANUAL AIR VENT
PRESSURE/TEMPERATURE TAP WITH
BALL VALVE
PRESSURE SWITCH
PLUG VALVE
FLOW SWITCH
T&P RELIEF VALVE
AUTOMATIC AIR VENT
PRESSURE GAUGE WITH GAUGE COCK
PS
FS
BUTTERFLY VALVE
STRAINER WITH BLOWDOWN VALVE,
CAP, AND CHAIN
FLOW MEASURING/BALANCING/SHUT-
OFF VALVE
GATE VALVE
CHECK VALVE
BALL VALVE
CONCENTRIC REDUCER
DIRECTION OF FLOW
DIRECTION OF SLOPE DOWN
ECCENTRIC REDUCER
PIPE FLANGE
PIPE CAP
PIPE GUIDE (PG)
PIPE ANCHOR (PA)X
UNION
TEE OUTLET UP
CONDENSATE DRAIN
BRANCH BOTTOM CONNECTION
BRANCH TOP CONNECTION
ELBOW UP
ELBOW DOWN
RISE OR DROP
TEE OUTLET DOWN
M
M
FIRE DAMPER
H
DUCT MOUNTED HUMIDIFIER
EXHAUST AIR DUCT DOWN
EXHAUST AIR DUCT UP
RETURN AIR DUCT DOWN
30"x14"
SQUARE TO ROUND DUCT BRANCH TAKE-OFF
WITH 45 DEGREE BRANCH INLET
FLARED SPIN-IN WITH DAMPER AND
FLEX DUCT (DIFFUSER CONNECTION)
ROUND DUCT BRANCH TAKE-OFF FROM
RECTANGULAR MAIN WITH CONICAL TAP
FLEXIBLE DUCT CONNECTION FLOW ARROW
DUCT SIZE TRANSITION
RECTANGULAR DUCT BRANCH TAKE-OFF
WITH 45 DEGREE BRANCH INLET
90 DEGREE DUCT ELBOW WITH TURNING VANES
24"Ø
DUCTWORK LEGEND
RETURN AIR DEVICE
ROUND DUCT. DIAMETER INDICATED IN INCHES.
IN-LINE 90 DEGREE RISE/DROP IN
SUPPLY DUCT (RIGHT SIDE IS HIGHER)
IN-LINE 90 DEGREE RISE/DROP IN
SUPPLY DUCT (LEFT SIDE IS HIGHER)
FD
SD
P - PNEUMATIC-ACTUACTED DAMPER
DAMPER TYPE:
M - MOTORIZED DAMPER (ELECTRIC)
VD
SMOKE DAMPER
VOLUME/BALANCING DAMPER
(LABEL MAY BE OMITTED)
BD
BACKDRAFT DAMPER
(COUNTER-BALANCED UNLESS
OTHERWISE NOTED)
RADIUS DUCT ELBOW - ROUND OR
RECTANGULAR (MIN. 1.5 RADIUS UNLESS
OTHERWISE NOTED)
RECTANGULAR DUCT. SIZE INDICATED IN
INCHES, FIRST NUMBER IS SIDE SHOWN.
DASHED LINES INDICATE ACOUSTICAL LINER
SUPPLY AIR DIFFUSER -
FLOW ARROWS INDICATE AIR PATTERN.
NO FLOW ARROWS SHOWN INDICATES
4-WAY PATTERN.
FSD
COMBINATION
FIRE/SMOKE DAMPER
EXHAUST AIR DEVICE
SERVICE CLEARANCE
T THERMOSTAT
REFRIGERANT LIQUIDRL
HEATING HOT WATER RETURNHWR
HEATING HOT WATER SUPPLYHWS
REFRIGERANT SUCTIONRS
CD
DEMOLISHED
CONNECT TO EXISTING
DISCONNECT FROM EXISTING
IN-LINE 90 DEGREE RISE/DROP IN
RETURN DUCT (RIGHT SIDE IS HIGHER)
DUCT SIZE TRANSITION RECTANGULAR TO
ROUND
30"/14" FLAT OVAL DUCT. SIZE INDICATED IN INCHES,
FIRST NUMBER IS SIDE SHOWN
RETURN AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT DOWN
SUPPLY OR OUTSIDE AIR DUCT UP
IN-LINE 90 DEGREE RISE/DROP IN
RETURN DUCT (LEFT SIDE IS HIGHER)
IN-LINE 90 DEGREE RISE/DROP IN
EXHAUST DUCT (RIGHT SIDE IS HIGHER)
IN-LINE 90 DEGREE RISE/DROP IN
EXHAUST DUCT (LEFT SIDE IS HIGHER)
DEMOLITION KEY
CONNECTION SIZE
(X"xX" INDICATES RECTANGULAR, X"/X"
INDICATES OVAL, X"Ø INDICATES ROUND)
X"xX"
TYP. OF #
TYPICAL OF QUANTITY INDICATED
FLEXIBLE PIPE CONNECTION
SKD
DUCT MOUNTED SMOKE DETECTOR
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
MECHANICAL ABBREVIATIONS AND
LEGENDS
M-002
-2
M -0
/2
/1
.p d f
16 17 18 19 2015
X
Y
Z
AA
"x
"x
"x
"x
"x
16"x10"
14"x10" 16"x10"10"x8"8"x6"
14"x8"
20"x12"18"x12"
18"x12"
14"x12"
28"x12"
18"x8"18"x8"
16"x8"12"x8" 1 "x
10"x6"
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
LEVEL 1 MECHANICAL DEMOLITION
PLAN
MD-101
-2
M D
-1
/2
/1
.p d f
SHEET NOTES:
SCALE: 3/16" = 1'-0"A1
LEVEL 1 OVERALL HVAC DEMOLITION PLAN
1. COORDINATE ALL DEMOLITION WORK WITH ARCHITECTURAL,
STRUCTURAL PLANS AND ELECTRICAL PLANS.
2. UNLESS NOTED OTHERWISE, MECHANICAL DEMOLITION SHALL
BE CARRIED OUT TO THE EXTENT SHOWN AND DEEMED
NECESSARY. CONTRACTOR SHALL VERIFY ALL EXISTING FIELD
CONDITIONS IN ORDER TO DETERMINE THE EXTENT OF WORK
UNDER THIS SECTION.
3. EXISTING EQUIPMENT AND ASSOCIATED DUCTWORK SHOWN
ON THE PLANS MAY NOT EXACTLY MATCH WITH THE FIELD
CONDITIONS. EQUIPMENT AND DUCTWORK LOCATION
DEPICTED HERE IS FOR PURPOSE OF COORDINATION.
CONTRACTOR SHALL VERIFY EXISTING DUCTWORK ROUTING
AND LOCATIONS AND MAKE ADJUSTMENTS AS REQUIRED TO
AVOID CONFLICTS WITH NEW DUCTWORK, EQUIPMENT, LIGHT
FIXTURES ETC.
4. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DUCT
DIMENSIONS AFTER PARTIAL DEMOLITION THAT REQUIRE
CONNECTION TO NEW DUCTWORK AND PROVIDE REQUIRED
TRANSITION PIECE TO NEW DUCTWORK.
5. BUILDING WILL BE IN OPERATION DURING CONSTRUCTION. ALL
SERVICE INTERRUPTIONS TO THE EXISTING FACILITY SHALL BE
SCHEDULED AND COORDINATED 3 WEEKS IN ADVANCE.
COORDINATE ALL DISRUPTIVE AND OUTAGE REQUIREMENTS
WITH COR.
6. CONTRACTOR TO PROTECT EXPOSED DUCT OPENINGS
DURING CONSTRUCTION.
7. REMOVE ALL DUCT INSULATION WHERE DUCT IS BEING
DEMOLISHED AND REPLACE PER SPECIFICATIONS. DUCT
LABELS SHALL BE INSTALLED EVERY 12 FT IN EXPOSED AREAS.
COLORS SHALL BE INDUSTRY STANDARD.
8. VAVs AND DUCTWORK SHOWN ON THE PLANS ARE LOCATED IN
THE INTERSTITIAL SPACE ABOVE THIS FLOOR.
9. DURING DEMOLITION TURN OVER THE EXISTING THERMOSTATS
TO COR OR THE FACILITIES TEAM.
10. CONTRACTOR TO PROVIDE PROTECTIVE DUCT FILM WRAP TO
EXISTING DUCTWORK AND ALL ASSOCIATED FITTINGS AND
VALVES DURING DEMOLITION AND CONSTRUCTION.
11. DEMOLISH ALL EXISTING CONTROLS INCLUDED BUT NOT
LIMITED TO THERMOSTATS, CONTROL WIRING.
1 DEMOLISH SUPPLY DIFFUSER, ASSOCIATED DAMPER, SUPPLY
DUCT AND VAV UPTO THE MAIN SUPPLY DUCT AND PROTECT
OPENING DURING CONSTRUCTION.
(TYP.)
KEY NOTES:
2 DEMOLISH RETURN REGISTER, ASSOCIATED VOLUME DAMPER
AND RETURN DUCT UPTO THE MAIN RETURN DUCT AND
PROTECT OPENING DURING CONSTRUCTION.
(TYP.)
(TYP.)
3 DEMOLISH EXHAUST GRILLE, ASSOCIATED VOLUME DAMPER
AND EXHAUST DUCT UPTO THE MAIN EXHAUST DUCT AND
PROTECT OPENING DURING CONSTRUCTION.
16 17 18 19 20
W
X
Y
Z
AA
T
VAV-1
VAV-2
VAV-3
VAV-4
VAV-13
VAV-5
VAV-8
VAV-7
VAV-9
VAV-10 VAV-11
VAV-6
1" HWR
1" HWS
1" HWR
1" HWS
1" HWS 1" HWR
1" HWR
1" HWS
1" HWS
1" HWR
1" HWR 1" HWS
/4
H
W S
/4
H
W R
VAV-14
VAV-15
AC-1
BREAK/MEETING
ROOM
2H-104
CLOSET
2H-123
TOUCHDOWN
2H-103
TOUCHDOWN
2H-120
ANESTHESIA
2-PERSON
OFFICE
2H-115
ANESTHESIA
OFFICE
2H-114
TOUCHDOWN
2H-121
STORAGE
2H-105
ELEC. CLOSET
2H-106
IT CLOSET
2H-107
RESIDENTS
2H-122
NEW 2-PERSON
ENGINEERING
OFFICE
2K-140A
NEW
ENGINEERING
OFFICE
2H-140B
TOUCHDOWN
2H-111
ANESTHESIA
OFFICE
2H-118
ANESTHESIA
OFFICE
2H-119
ANESTHESIA
OFFICE
2H-113
STAFF LOCKER
2H-110
CORRIDOR
C2H-6
CORRIDOR
C2H-7
CORRIDOR
C2H-5
CORRIDOR
C2H-4
ANESTHESIA
ADMIN.
2H-112
WELLNESS ROOM
2H-108
STAFF TOILET
2H-109
ANESTHESIA
OFFICE
2H-116
ANESTHESIA
OFFICE
2H-117
VESTIBULE
2K-140C
CORRIDOR
C2H-4
STORAGE
2H-141B
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
MECHANICAL PIPING PLAN
MP-101
-2
M P
-1
/1
/2
.p d f
SCALE: 3/16" = 1'-0"1
LEVEL 1 OVERALL HVAC PIPING PLAN
SHEET NOTES:
1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND
DESIGN CRITERIA.
2. REFER TO M-002 FOR MECHANICAL ABBREVIATIONS AND
LEGENDS.
3. DUCTWORK , VAVs , REHEAT COILS , HOT WATER PIPING AND
ASSOCIATED VALVES SHOWN ON THE FLOOR PLAN FOR
CONNECTIVITY AND CLARITY ARE LOCATED IN THE
INTERSTITIAL SPACE ABOVE THIS FLOOR.
4. REFER TO MECHANICAL SCHEDULES FOR RUN OUT PIPE SIZES
TO THE VAVs.
5. ALL HOT WATER PIPING AND ASSOCIATED VALVES SHOWN ON
THE FLOOR PLAN ARE LOCATED IN THE INTERSTITIAL SPACE
ABOVE THIS FLOOR.
1 EXISTING HOT WATER LINES FROM EXISTING BOILER ROOM
2 POINT OF CONNECTION OF NEW HOT WATER LINES WITH THE
EXISTING HOT WATER LINES.
KEY NOTES:
3 ROUTE CONDENSATE DRAIN FROM AC-1 TO SANITARY LINE AT
THE TOILET AS SHOWN.
16 17 18 19 20
W
X
Y
Z
AA
TOUCHDOWN
2H-103
BREAK/MEETING
ROOM
2H-104
CORRIDOR
C2H-6
TOUCHDOWN
2H-121
TOUCHDOWN
2H-120
RESIDENTS
2H-122
CORRIDOR
C2H-5
IT CLOSET
2H-107
ELEC. CLOSET
2H-106
ANESTHESIA
ADMIN.
2H-112
TOUCHDOWN
2H-111
ANESTHESIA
OFFICE
2H-116
NEW 2-PERSON
ENGINEERING
OFFICE
2K-140A
STAFF TOILET
2H-109
WELLNESS ROOM
2H-108
NEW
ENGINEERING
OFFICE
2H-140B
STAFF LOCKER
2H-110
10"Ø
SD-1
325 CFM
10"Ø
SD-1
325 CFM
10"Ø
SD-1
350 CFM
10"Ø
SD-1
350 CFM
12"Ø
SD-1
450 CFM
8"Ø
SD-1
260 CFM
8"Ø
SD-1
260 CFM
8"Ø
SD-1
260 CFM
8"Ø
SD-1
250 CFM
6"Ø
SD-1
150 CFM
6"Ø
SD-1
100 CFM
6"Ø
SD-1
100 CFM
6"Ø
SD-1
100 CFM
8"Ø
SD-1
200 CFM
6"Ø
SD-1
100 CFM
6"Ø
SD-1
100 CFM
6"Ø
SD-1
50 CFM
10"Ø
SD-1
300 CFM
10"Ø
SD-1
300 CFM
10"Ø
SD-1
300 CFM
10"Ø
SD-1
300 CFM
6"Ø
SD-1
125 CFM
6"Ø
SD-1
125 CFM
6"Ø
SD-1
125 CFM
6"Ø
SD-1
125 CFM
12"x10"10"Ø
"x
"x
12"Ø
14"x10"10"Ø
"Ø
12"x10"10"Ø
"x
16"x10"8"Ø
12"x10"
RG-1
650 CFM
12"x10"
"x
12"x10"
RG-1
500 CFM
6"x6"
RG-1
100 CFM8"x8"
RG-1
150 CFM
16"x8"
"x
12"x10"
"x
10"x10"
RG-1
450 CFM
12"x10"
RG-1
700 CFM
8"x8"
RG-1
250 CFM
6"x6"
RG-1
100 CFM
6"x6"
RG-1
100 CFM
6"x6"
RG-1
200 CFM
T
T
T
T
T
T
T
T T
T
T
VAV-1
VAV-2
VAV-3
VAV-4
VAV-5
VAV-6
VAV-7
VAV-8
VAV-9
VAV-10 VAV-11
VAV-13
ANESTHESIA
OFFICE
2H-117
6"Ø
SD-1
100 CFM
6"Ø
SD-1
100 CFM
ANESTHESIA
OFFICE
2H-119
10"x8"
6"x6"
RG-1
100 CFM
6"Ø
8"Ø
10"x8"
12"x10"
RG-1
390 CFM
12"x10"
RG-2
600 CFM
10"x8"
SD-2
300 CFM
10"x8"
10"x8"
EG-2
300 CFM
10"x8"
6"x6"
RG-1
100 CFM
ANESTHESIA
2-PERSON
OFFICE
2H-115
ANESTHESIA
OFFICE
2H-113 6"x6"
RG-1
100 CFM
STORAGE
2H-105
STORAGE
2H-141B
ANESTHESIA
OFFICE
2H-118 8"x8"
EG-1
100 CFM
8"x8"
EG-1
100 CFM
6"Ø
SD-1
100 CFM
6"x6"
EG-1
50 CFM
6"x6"
RG-1
100 CFM
10"x8"
"x
"x
"x
6"x6"
RG-1
100 CFM
6"Ø
SD-1
100 CFM
6"Ø
SD-1
50 CFM
"x
6"x6"
RG-1
100 CFM
T
T
6"Ø
SD-1
50 CFM
VAV-14
VAV-15
T
8"x8"
RG-1
150 CFM
12"x10"
RG-1
600 CFM
12"x10"
RG-1
390 CFM
AC-1
ANESTHESIA
OFFICE
2H-114
8"x6"
EG-1
50 CFM
8"x6"
EG-1
50 CFM
12"x8"
8"x6"
8"x6"
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
LEVEL 1 MECHANICAL FLOOR PLAN
M-101
-2
M -1
/2
/1
.p d f
SCALE: 3/16" = 1'-0"A1
LEVEL 1 MECHANICAL PLAN
SHEET NOTES:
1. REFER TO M-001 FOR MECHANICAL GENERAL NOTES AND
DESIGN CRITERIA.
2. REFER TO M-002 FOR MECHANICAL ABBREVIATIONS AND
LEGENDS.
3. REFER TO ARCHITECTURAL DWGS FOR EXACT LOCATIONS AND
MOUNTING HEIGHTS FOR SUPPLY DIFFUSERS, RETURN
REGISTERS AND EXHAUST GRILLES.
4. RUNOUTS TO TERMINAL UNITS SHALL BE SAME SIZE AS INLET
DIAMETERS TO VAV BOXES AS SCHEDULED.
5. RUNOUTS TO SUPPLY DIFFUSERS, RETURN REGISTERS AND
EXHAUST GRILLES SHALL BE SAME SIZE AS NECK SIZE OF THE
RESPECTIVE DIFFUSERS, REGISTERS AND GRILLES.
6. DUCTWORK , VAVs , REHEAT COILS , HOT WATER PIPING AND
ASSOCIATED VALVES SHOWN ON THE FLOOR PLAN FOR
CONNECTIVITY AND CLARITY ARE LOCATED IN THE
INTERSTITIAL SPACE ABOVE THIS FLOOR.
1 PROVIDE NEW VAV AS SCHEDULED. DUCT RUNOUT TO VAV
BOX SHALL BE THE SAME AS INLET DIAMETER TO VAV AS
SCHEDULED. PROVIDE NEW ASSOCIATED THERMOSTATS AND
INTEGRATE WITH EXISITNG BUILDING DDC SYSTEM.
2 PROVIDE NEW DIFFUSER WITH ASSOCIATED MANUAL VOLUME
DAMPER. FLEX DUCT RUNOUT TO SUPPLY AIR DIFFUSER
SHALL BE THE SAME AS NECK SIZE OF THE DIFFUSER.
3 PROVIDE NEW RETURN REGISTER WITH ASSOCIATED MANUAL
VOLUME DAMPER. FLEX DUCT RUNOUT TO SUPPLY AIR DIFFUSER
SHALL BE THE SAME AS NECK SIZE OF THE DIFFUSER.
KEY NOTES:
4 PROVIDE WALL MOUNTED INDOOR AC UNIT AS SHOWN.
OUTDOOR UNIT SHALL BE LOCATED ON THE ROOF. PROVIDE
REFRIGERANT PIPING FROM INDOOR UNIT TO THE OUTDOOR
UNIT PER MANUFACTURER'S RECOMMENDATIONS. ROUTE
CONDENSATE FROM THE INDOOR AC UNIT TO STAFF TOILET
2H-109 TO DRAIN INTO THE TOILET FIXTURE. REFER TO
MECHANICAL SCHEDULES M601 FOR MORE INFORMATION ON
AC-1 AND ACU-1.
SECTION "A-A"
"B" "B"
NOTES:
1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY.
2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS.
3. SEE SMACNA 2005, FIGURE 9-15
ACCESS PANEL
ACCESS DOOR
CASING
GASKET
HANDLE INSIDE
FLEXIBLE
WASHER
FACTORY
FABRICATED
LATCH
SECTION "B-B"
INSULATION
DUCT
GASKET
INSULATION
INSULATION
"A"
"A"
NOTE:
1.
2.
3.
4.
ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA.
WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE
REGARDLESS OF W DIMENSION.
ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM
SPACE BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE.
WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE
VANE TYPE.
W
W1
VANE
VANE
NOTE:
1.
2.
THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.
ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS ELBOWS. ALL
SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED,
SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA.
R SHALL
EQUAL
OR BE
GREATER
THAN W.
R SHALL
EQUAL
OR BE
GREATER
THAN
1/3W.
R SHALL
EQUAL
OR BE
GREATER
THAN
1/6W.
STANDARD RADIUS OR
LONG RADIUS ELBOW
SHORT RADIUS ELBOW
WITH ONE VANE
SHORT RADIUS ELBOW
WITH TWO VANES
W
R
R
2/3W
/3
W
W W
1/2W
/3
W
1/6W
R
ROUND FLEXIBLE CONNECTION
RECTANGULAR FLEXIBLE CONNECTION
FLANGED
CONNECTION ON FAN
SIDE
WASHER 1-1/2" [40mm] MIN. TO 3" [75mm] MAX.
INSTALLED. 6" [150mm] NOMINAL WITH
MATERIAL TAUT
FLEXIBLE
MATERIAL AS
SPECIFIED
1"x1/8" [25x3mm] DRAW BAND
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
5/16" [8mm] FLANGE
DUCT
SHEET METAL SCREWS ON
12" [300mm] CENTERS
RIVET ON 4"
[100mm] CENTERS
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
1" [25mm] FLANGE & HEMALTERNATE
POSITION
OF BOLT 1 1/2" [40mm]
POCKET SLIP
DUCT
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
[15mm] [15mm] [40mm]
1 1/2" [40mm] MIN. TO 3" [75mm] MAX.
INSTALLED. 6" [150mm] NOMINAL WITH
MATERIAL TAUT
FLANGED
CONNECTION
ON FAN SIDE
WASHER
FLEXIBLE MATERIAL
AS SPECIFIED
1/2" 1/2" 1 1/2"
MAIN EXHAUST OR RETURN
PLAN VIEW
AIR
FLOW AIR
FLOW
PROVIDE VOLUME DAMPER
AT EACH BRANCH DUCT
1/4W OR 4" [100mm]
MIN.
BRANCH DUCT
VD
W
2500 [1133]
1320 [598]
420 [190]ONE 1 [25] x 18 GA STRAP36 [900]
TWO 1/2 [13]∅ RODS
TWO 3/8 [10]∅. RODS
ONE 1 [25] x 16 GA STRAP
84 [2100]
60 [1500]
50 [1250] 700 [317]
ONE 1 [25] x 22 GA STRAP
QUANTITY/SIZEMAX. DUCT ∅
26 [650]
HANGER STRAPS OR RODS
MAX. LOAD
LBS. [kg]
260 [119]
MAX.
144 [3600]
IN. [mm]
SPACING
IN. [mm] IN. [mm]
144 [3600]
144 [3600]
144 [3600]
144 [3600]
NOTE:
TABULATED DATA FROM SMACNA
ALLOWS FOR DUCT REINFORCING AND
INSULATION, BUT NO EXTERNAL LOAD.
BAND
OVER 50"
[1250mm]∅
HANGER RODS
BAND OF SAME
SIZE AS HANGER
STRAP
LOAD RATED
FASTENERS
50" [1250mm]∅
& UNDER
AIR SPLIT DUCT TAKE-OFF PLAN
VIEW
BRANCH DUCT TAKE-OFF PLAN VIEW
SUPPLY REGISTER TAKE-OFF
PLAN VIEW
AIR
FLOW
AIR
FLOW
A
IR
F L O
W
SUPPLY REGISTER
OR BRANCH DUCT
TURNING VANES
MAIN
SUPPLY
DUCT
SEE FLOOR PLAN FOR
SPLIT DIMENSION
PROVIDE VOLUME
DAMPER
PROVIDE VOLUME
DAMPER
ADJUSTABLE
METAL ROD
OR LINKAGE
TOP REGISTER
MAIN
SUPPLY
DUCT
VOLUME EXTRACTOR; ADJUSTABLE
FROM FULLY CLOSED POSITION TO
CFM NOTED ON FLOOR PLANS
AIR
FLOW
AIR
FLOW
1/4 W OR 4" [100mm] MIN.
AIR
FLOW
MAIN SUPPLY
DUCT
A
IR
F L O
W
W
FROM STRUCTURE
SAME AS DIFFUSER
INLET: 5'-0" MAX
FLEXIBLE DUCT SIZE
LENGTH.
12"
CEILING
SUPPORT SADDLE
VOLUME DAMPER W/
LOCKING QUADSADDLE
SHEET METAL
CONICAL OUTLET
BRANCH DUCT
FOR CHANGE OF
DIRECTION GREATER
USE RIGID ELBOWS
THAN 45°
[300mm]
SEE SPECIFICATIONS FOR CLAMPS
AND SEALANT (TYP.)
NOTE:
THE USE OF FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED FOR
THE DEDICATED AHU SERVING THE SURGICAL SUITE.
TYPICAL
DIFFUSER OR
REGISTER IN
LAY-IN CLG.
THERMAL INSULATION
SEE SPECIFICATIONS
m m
M A
X
SIDE VIEW TRAPEZE HANGER FOR UP TO
453KG [1000 LB.] UNIFORM LOAD
ADJUSTABLE CLEVIS HANGER TYPE 1 - SEE SPECIFICATIONS ADJUSTABLE CLEVIS HANGER TYPE 43 - SEE SPECIFICATIONS
MAXIMUM PIPE/TUBING SUPPORT SPACING
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
NOM. SIZE
PIPE
TUBING
mm
[IN]
mm
[FT]
mm
[FT]
THRU 20
[THRU 3/4]
[7]
[5]
[1]
[7]
[6]
[11/4]
[7]
[7]
[11/2]
[9]
[8]
[2]
[10]
[8]
[21/2]
[11]
[9]
[3]
[12]
[10]
[4]
[14]
[12]
[5]
[16]
[13]
[6]
[17]
[14]
[8]
[19]
[16]
[10]
[22]
[12]
[23]
[14]
[25]
[16]
[27]
[18]
[28]
[20]
[30]
[24]
[32]
PROVIDE INSULATION
SHIELD
& INSERT FOR ALL
PIPING
(200mm [8"] MIN.)
BAND
43mm [1-5/8"] 12 GAUGE CHANNEL OR 50x50x6.4mm
[2"X2"X1/4"] ANGLE
15mm [1/2"] DIA.
HANGER RODS WITH
900mm [36"] MAX.
SPACING ON EACH
CHANNEL
WELD
SADDLE
INSULATION SHIELD
AT HANGER
PROVIDE HIGH COMPRESSIVE
STRENGTH INSULATION (9
PSF MIN. DENSITY) UNDER
INSULATION SHIELD
INSULATION (VAPOR
BARRIER TYPE IS
REQUIRED FOR LOW
TEMPERATURE PIPE)
HANGER ROD
NOTE:
SEE SPECIFER FOR DETAILED HANGER
REQUIREMENTS
4" THICK CONCRETE PAD
(MIN. 4" EXTENSION ALL
SIDES)
OUTDOOR UNIT. SECURE
TO CONCRETE PAD.
PROVIDE VIBRATION
PANS UNDER UNIT.
POWER & HIGH
VOLTAGE
CONTROL
TO INDOOR UNIT
THERMISTOR
CABLE
CONDENSATE
LINE.
WALL SLEEVE WITH CAPS
FURNISHED BY FCU
MFGR.
WALL MOUNTING
BRACKET FURNISHED BY
FCU MFGR.
INDOOR
UNIT
INSULATED RS AND RL
REFRIGERANT LINES
CONNECTION CABLE
TO THERMOSTAT
TOP OF
UNIT ± 8' AFF
AIRFLOW
SA
AIRFLOW
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
MECHANICAL DETAILS
M-501
-2
M -5
/1
/1
.p d f
SCALE: N.T.S.A12
ACCESS DOORS AND PANELS
SCALE: N.T.S.H12
DUCTWORK - SQUARE ELBOWS SCALE: N.T.S.H8
DUCTWORK -RADIUS ELBOWS
SCALE: N.T.S.D12
FLEXIBLE CONNECTORS
SCALE: N.T.S.H4
RETURN/EXHAUST BRANCH DUCTWORK
SCALE: N.T.S.D8
ROUND DUCT HANGERS
SCALE: N.T.S.H16
SUPPLY DUCTWORK TAKEOFFS
SCALE: N.T.S.D16
VAV FLEXIBLE DUCT CONNECTOR
SCALE: N.T.S.A7
PIPE HANGERS
SCALE: N.T.S.A16
WALL MOUNTED DUCTLESS SPLIT SYSTEM
(in.) (CFM) (°F)
(in)
VAV-1 TOUCHDOWN 2H-103 8 650 200
VAV-2 BREAKROOM 2H-104 8 1200 500
VAV-8
OFFICE 2H-119
8 500
VAV-9 6 200
VAV-10 10 780
VAV-11
OFFICE 2K-140A, 2H-140B,
WELLNESS 2H-108
6 300
VAV-3 TOUCHDOWN 2H-120 10 700 250
VAV-4 8 450 150
VAV-5 OFFICE 2H-113,114 ,115 6 350 125
VAV-6 RESIDENTS 2H-122 6 250 100
VAV-7 OFFICE 2H-116, 117, 118 6 300 125
VAV-13 ELECTRICAL 6 300
VARIABLE AIR VALVE (VAV) SCHEDULE
TAG SERVICE INLET
DIA. SIZE
MAX.
COOLING
EAT PIPE
SIZE
TOUCHDOWN 2H-121
ADMIN 2H-112
TOUCHDOWN 2H-111
MIN.
HEATING
(CFM)
AIRFLOW RANGE
MAX. NC
LEVEL AT
MAX.
AIRFLOW
(NC)
(°F)
LAT FLOW
(GPM)
MIN.
HEATING
CAP.
BASIS OF
DESIGN
NOTES
AIRSIDE WATERSIDE
6.5
3.7
2.0
6.5
2.7
3.9
1.4
2.7
2.7
16.2
6.3
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV0.65
1.62
0.63
0.39
0.27
0.14
0.27
0.37
0.2
0.65
0.27
1. DISCONNECT BY ELECTRICAL CONTRACTOR.
2. PRESSURE INDEPENDENT CONTROLS.
3. BAS INTERFACE: MONITORING AND CONTROLS.
4. MANUFACTURER PROVIDED CONTROL PANEL.
5. PROVIDE INTEGRAL 24V TRANSFORMER WITHIN ENCLOSURE AND INCLUDE SWITCH.
6. MAX NC LEVEL SHALL NOT EXCEED 30.
7. 1" INSULATION PRE-INSTALLED BY MANUFACTURER.
NOTES:
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
VAV-14 CORRIDOR 4 150 30 55 75 TITUS DESV3/4100 2.00.20
REHEAT COIL
VAV-15 LOCKERS 4 100 30 55 75 TITUS DESV3/450 2.00.20
SD-1 SUPPLY AL RADIAL HORIZONTAL SQUARE PLAQUE DIFFUSER TITUS OMNI
1. REFER TO DRAWINGS FOR NECK SIZES.
2. REFER TO ARCHITECTURAL RCP DRAWINGS FOR COORDINATION WITH CEILING.
3. COORDINATE FINISH WITH ARCHITECT.
4. COORDINATE MOUNTING HEIGHTS WITH ARCHITECTURAL ELEVATIONS.
RG-1 RETURN STEEL TITUS 350RL
NOTES:
GRILLE AND DIFFUSER SCHEDULE
TAG SERVICE MOUNTING
MODULE SIZE
MATERIAL DESCRIPTION BASIS OF DESIGN NOTES(in. x in.)
SEE DWGS 24 x 24
SIDE WALL SEE DWGS
RG-2 RETURN CEILING 24 x 24 AL 1/2"X1/2"X1/2" GRID EGGCRATE FACE RETURN GRILLE TITUS 50F 1,2,3,4,5
1,2,3,4,5
1,2,3,4,5
DOUBLE DEFLECTION GRILLE
EG-1 EXHAUST CEILING 12 x 12 AL 1/2"X1/2"X1/2" GRID EGGCRATE FACE EXHAUST GRILLE TITUS 50F 1,2,3,4,5
SD-2 SUPPLY SIDE WALL SEE DWGS STEEL
SINGLE DEFLECTION RETURN GRILLE
TITUS 350FL 1,2,3,4,5
EG-2 EXHAUST SIDE WALL SEE DWGS STEEL SINGLE DEFLECTION RETURN GRILLE TITUS 350RL 1,2,3,4,5
AC-1 COMM RM DUCTLESS SPLIT 738 0 0 9,800 24,000 20.5 80 67 95 N/A 1.00 20.00 208 60 1
MITSUBISHI MY-GL24NA,
MUY-GL24NA
1-8
DB (F) WB (F) MCA MCA
MIN
CAPACITY
(BTU/H)
RATED
CAPACITY
(BTU/H)
SEER
EAT OSA
DESIGN
TEMP (F)
INDOOR UNIT OUTDOOR UNIT
VOLT HZ PHASE
SPLIT SYSTEM AIR CONDITIONER (INDOOR AND OUTDOOR UNIT) SCHEDULE
TAG
SERVICE TYPE
TOTAL SUPPLY
AIRFLOW (CFM)
MIN. OUTSIDE
AIR FLOW
(CFM)
EXT STATIC
PRESSURE
(IN)
COOLING CAPACITY
HEATING
CAPACITY
ELECTRICAL DATA
BASIS OF DESIGN NOTES
INDOOR OUTDOOR
ACU-1 208 60 1
VOLT HZ PHASE
NOTES:
1. PROVIDE WALL MOUNTED THERMOSTAT TO THE UNIT AS INDICATED ON MECHANICAL FLOOR PLANS.
2. PROVIDE HARD WIRED THERMOSTAT TO CONTROL THE UNIT.
3. DISCONNECT TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR.
4. PROVIDE WALL MOUNTED KIT FOR INDOOR UNIT.
5. INDOOR UNIT AND OUTDOOR CONDENSING UNIT SHALL BE INTERLOCKED.
6. PROVIDE HAIL GUARD ON OUTDOOR UNIT.
7. REFER TO PLAN FOR CONDENSATE DRAIN LOCATION.
8. LOW AMBIENT COOLING.
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
MECHANICAL SCHEDULES
M-601
-2
M -6
/2
/1
.p
END OF RUN:
M
SASA
T
FS
M
T
SEQUENCE OF OPERATION - VARIABLE AIR VOLUME (VAV) UNIT
EQUIPMENT
THE AIRSIDE SYSTEMS, AS IT APPLIES TO THE BUILDING AUTOMATION SYSTEM
(BAS), CONSISTS OF THE FOLLOWING EQUIPMENT:
VARIABLE AIR VOLUME (VAV) UNITS,
GENERAL
AIR TERMINAL UNITS SHALL BE PRESSURE INDEPENDENT UNITS, WITH HOT
WATER REHEAT COILS (WHERE APPLICABLE). EACH UNIT SHALL BE SUPPLIED
WITH CUSTOM PROGRAMMABLE APPLICATION CONTROLLERS. THE BAS SHALL
PERFORM THE FOLLOWING TERMINAL UNIT CONTROL STRATEGIES AND PROVIDE
THE POINTS AS REQUIRED FOR THE SPECIFIED MONITORING AND DIAGNOSTICS:
SETPOINT CONTROL: THE BAS SHALL EDIT THE OPERATING MODE, AIRFLOW
SETPOINTS, DAMPER POSITIONS, AND ZONE TEMPERATURE SETPOINT OF EACH
BOX. ALL SETPOINTS SHALL BE OPERATOR ADJUSTABLE. INDIVIDUAL ZONE
SETPOINT AND CONTROL LOGIC SHALL RESIDE AT THE ZONE LEVEL, AND NOT BE
DEPENDENT UPON THE BAS FOR CONTROL. UPON LOSS OF COMMUNICATION, THE
TERMINAL UNIT WILL CONTINUE TO CONTROL TO CURRENT SETPOINTS.
RUN CONDITIONS
TERMINAL UNIT/ AHU INTERFACE:
AT MINIMUM, ALL TERMINAL UNITS (TU) SERVED BY AN AIR HANDLING UNIT (AHU)
SHALL BE LINKED WITH THE RESPECTIVE AHU CONTROLLER TO PERFORM THE
FOLLOWING FUNCTIONS:
ZONE OCCUPANCY SCHEDULE: THE SCHEDULE SHALL AUTOMATICALLY SELECT
THE OCCUPIED OR UNOCCUPIED OPERATING MODE OF THE AHU. ACTIVATION OF
TIMED OVERRIDE SWITCH ON ZONE TEMPERATURE SENSORS (WHERE
APPLICABLE)SHALL ONLY RESET ZONE HEATING AND COOLING SETPOINTS TO
"OCCUPIED" VALUES, BUT SHALL NOT OTHERWISE AFFECT SCHEDULED
UNOCCUPIED OPERATING MODE OF AHU.
DUCT STATIC PRESSURE ALGORITHM: SEE AHU CONTROL SEQUENCE.
ZONE OPTIMAL START:
THE UNITS SHALL USE AN OPTIMAL START ALGORITHM FOR MORNING START-UP.
THIS ALGORITHM SHALL MINIMIZE THE UNOCCUPIED WARM-UP OR COOL-DOWN
PERIOD WHILE STILL ACHIEVING COMFORT CONDITIONS BY THE START OF THE
SCHEDULED OCCUPIED PERIOD. THE LEARNING ADAPTIVE ALGORITHM SHALL
COMPARE THE ZONE TEMPERATURE TO ITS SETPOINT AT THE BEGINNING OF
SCHEDULED OCCUPIED PERIOD AND SHALL AUTOMATICALLY ADAPT THE HEATING
OR COOLING RESPONSE TIME FOR THE NEXT UNOCCUPIED PERIOD. THE INITIAL
DEFAULT STARTING TIME PRIOR TO OCCUPANCY SHALL BE 60 MINS (ADJ).
ZONE TEMPERATURE AND AIRFLOW CONTROL
OCCUPIED ZONE TEMPERATURE:
UNITS SHALL RUN TO MAINTAIN THE FOLLOWING TEMPERATURES:
75°F (ADJ) COOLING SETPOINT
70°F (ADJ) HEATING SETPOINT
UNOCCUPIED ZONE TEMPERATURE:
UNITS SHALL RUN TO MAINTAIN THE FOLLOWING TEMPERATURES:
85°F (ADJ) COOLING SETPOINT
55°F (ADJ) HEATING SETPOINT
AIRFLOW SETPOINTS:
PROVIDE OPERATOR DEFINABLE, INDEPENDENT HEATING AND COOLING AIRFLOW
SETPOINTS PER VAV TERMINAL UNIT SCHEDULES.
SPACE CONDITION CONTROL:
THE TERMINAL UNIT (TU) SHALL MAINTAIN ZONE TEMPERATURE AND AIRFLOW SETPOINTS
BY CONTROLLING THE TU AIR DAMPER AND ZONE HEATING COIL VIA THE FOLLOWING:
OCCUPIED:
WHEN ZONE TEMPERATURE IS GREATER THAN ITS COOLING SETPOINT, THE ZONE DAMPER
SHALL MODULATE BETWEEN THE MINIMUM OCCUPIED AIRFLOW (ADJ) AND MAXIMUM
OCCUPIED AIRFLOW (ADJ) UNTIL ZONE TEMPERATURE IS SATISFIED. HEATING COIL VALVE
REMAINS CLOSED.
WHEN THE ZONE TEMPERATURE IS BETWEEN THE COOLING SETPOINT AND THE HEATING
SETPOINT, THE ZONE DAMPER SHALL MODULATE TO ITS MINIMUM OCCUPIED AIRFLOW
(ADJ). HEATING COIL VALVE REMAINS CLOSED.
VAV W/ REHEAT (VAV) : WHEN ZONE TEMPERATURE IS LESS THAN ITS HEATING SETPOINT,
THE CONTROLLER SHALL ENABLE THE HEATING COIL AND MODULATE THE HEATING COIL
VALVE TO MAINTAIN THE ZONE TEMPERATURE SETPOINT. THE HEATING AIRFLOW SHALL BE
LIMITED TO MINIMUM OCCUPIED AIRFLOW.
UNOCCUPIED:
THE TERMINAL UNITS SHALL CYCLE BETWEEN MINIMUM AND MAXIMUM AIRFLOW SETPOINTS
DURING UNOCCUPIED PERIODS. APPLY ± 3°F (ADJ) ALLOWABLE DRIFT FROM UNOCCUPIED
HEATING AND COOLING SETPOINTS AS DESCRIBED BELOW:
COOLING: WHEN CRITICAL ZONE (CZ) TEMPERATURE HAS RISEN ABOVE ITS UNOCCUPIED
SPACE TEMPERATURE COOLING SETPOINT PLUS THE DRIFT (3°F ADJ, AS STATED ABOVE),
THE AHU SHALL BEGIN STARTUP. THE CZ DAMPER SHALL OPEN TO ITS RESPECTIVE
MAXIMUM UNOCCUPIED COOLING MODE AIRFLOW SETPOINT AND REMAIN IN THIS POSITION
UNTIL THE ZONE TEMPERATURE IS AT SETPOINT MINUS THE DRIFT. THE ZONE CONTROLLER
SHALL THEN MODULATE THE ZONE DAMPER TO THE MINIMUM UNOCCUPIED COOLING MODE
AIRFLOW SETPOINT UNTIL CYCLE REPEATS.
HEATING: WHEN CRITICAL ZONE (CZ) TEMPERATURE HAS FALLEN BELOW ITS UNOCCUPIED
SPACE TEMPERATURE HEATING SETPOINT MINUS THE DRIFT, THE TU CONTROLLER SHALL
MODULATE THE ZONE DAMPER TO MINIMUM UNOCCUPIED HEATING MODE AIRFLOW
SETPOINT AND SHALL MODULATE THE HEATING COIL VALVE TO 100% OPEN. THIS SHALL
CONTINUE UNTIL ZONE TEMPERATURE IS AT SETPOINT PLUS THE DRIFT. THE ZONE
CONTROLLER SHALL THEN CLOSE THE HEATING COIL VALVE.
OVERRIDE: WHEN UNOCCUPIED MODE IS OVERRIDDEN BY USER AT LOCAL THERMOSTAT,
AHU IS TO ENERGIZE AND RUN IN OCCUPIED MODE FOR A 1 HOUR (ADJ) PERIOD BEFORE
RETURNING TO UNOCCUPIED MODE.
ALARMS AND SHUTDOWNS
NOTE: ALL ALARMS TO BE TIMESTAMPED ON BAS GRAPHIC
INTERFACE.
HIGH ZONE TEMPERATURE: IF THE ZONE TEMPERATURE IS GREATER
THAN THE COOLING SETPOINT BY 5°F (ADJ) FOR A MINIMUM OF 30
MINS (ADJ).
LOW ZONE TEMPERATURE: IF THE ZONE TEMPERATURE IS LESS
THAN THE HEATING SETPOINT BY 5°F (ADJ) FOR A MINIMUM OF 30
MINS (ADJ).
HIGH DISCHARGE AIR TEMPERATURE: IF THE TERMINAL UNIT
DISCHARGE AIR TEMPERATURE IS GREATER THAN 105°F (ADJ) FOR A
MINIMUM OF 30 MINS (ADJ).
HIGH AIRFLOW: IF THE ZONE AIRFLOW IS GREATER THAN THE
SETPOINT BY 25% (ADJ) FOR A MINIMUM OF 60 MINS (ADJ).
LOW AIRFLOW: IF THE ZONE AIRFLOW IS LESS THAN THE SETPOINT
BY 25% (ADJ) FOR A MINIMUM OF 60 MINS (ADJ).
DDC INPUT OUTPUT SUMMARY
VARIABLE AIR VOLUME (VAV) UNIT
S Y
S T
E M
G R
A P
H
IC
D
IS
P L A
Y
OUTPUTS INPUTS
SOFTWARE
REMARKS
DIGITAL ANALOG DIGITAL ANALOG
EQUIPMENT POINT DESCRIPTION
S T
A R
T /S
T O
P
O P
E N
/C L
O S
E
E N
A B
L E
/D
IS
A B
L E
S E
T P
O
IN
T A
D J U
S T
P O
S
IT
IO
N
V A
L V
E C
O M
M A
N D
S P
E E
D C
O N
T R
O L
C U
R R
E N
T S
E N
S
IN
G R
E L A
Y
D
IF
F E
R E
N T
IA
L P
R E
S S
U R
E S
W
IT
C H
S T
A R
T /S
T O
P
F L O
W S
W
IT
C H
O P
E N
/C L
O S
E
A L A
R M
P U
S H
B U
T T
O N
O V
E R
R
ID
E
P U
L S
E C
O N
T A
C T
T E
M P
E R
A T
U R
E
E L E
C T
R
IC
A L D
E M
A N
D k W
A M
P E
R A
G E
V F
D F
R E
Q U
E N
C Y
P R
E S
S U
R E
C A
R B
O N
D
IO
X
ID
E
P O
S
IT
IO
N
F L O
W
E N
T H
A L P
Y
H U
M
ID
IT
Y
A N
A L O
G V
A R
IA
B
L E
B
IN
A R
Y V
A R
IA
B
L E
S O
F T
A L A
R M
R U
N T
IM
E
T O
T A
L
IZ
A T
IO
N
R E
S E
T A
V A
IL
A
B L E
S C
H E
D U
L E
C A
L C
U L A
T E
D P
O
IN
T
VAV
VAV DAMPER POSITION X X X
VAV ZONE OCCUPIED/ UNOCCUPIED X X
VAV REHEAT HOT WATER CONTROL VALVE POSITION X X
VAV AIRFLOW (CFM) X X
VAV ZONE TEMPERATURE X X X ALARM PER SEQUENCE
VAV ZONE TEMPERATURE SETPOINT X X
VAV SUPPLY AIR TEMPERATURE X X X ALARM PER SEQUENCE
VAV ZONE SENSOR OVERRIDE STATUS X X
VAV ZONE SENSOR DIAL POSITION X X
UNIT AT END OF RUN SHALL HAVE 3-WAY VALVE
S E
T P
O
IN
T
R A
N G
E
75F
55F
0-100%
0-100%
AI
AI
AO
AI
AO
AO
ROOM THERMOSTAT/SENSOR
WALL MOUNTED
48" [1200mm] AFF.
NO SUPPLEMENTAL HEATING
TU
RHCHWS
HWR
V-1
REHEAT
COIL
AIR
TERMINAL
UNIT
AIR
FLOW
TE
ATU
CONTROLLER
PC
TE
A
IR
F
LO
W
(C F M
ROOM TEMPERATURE
(°F)
HEATING
MINIMUM
SP
VAV BOX CONTROL
SEQUENCE
W/DEADBAND
100%
VA
V
AI
R
FL
O W
R
EH
EAT
FLO
W
FE
A. SETPOINT SHALL BE SET AS
FOLLOWS:
COOLING 75F
(ADJ)
HEATING 70F
(ADJ)
DEADBAND OF 5 F BETWEEN HEATING AND COOLING SET POINTS
WILL BE
MAINTAINED.
B. UPON FALL IN SPACE TEMPERATURE THE VAV DAMPER WILL
MODULATE TO MINIMUM
POSITION.
C. UPON FURTHER DROP IN SPACE TEMPERATURE VALVE V-1 WILL
MODULATE TO MAINTAIN SET POINT +/_ 5F. THE ADJUSTABLE
TOLERANCE OF +/_ 5F HAS BEEN SELECTED TO PREVENT VALVE
HUNTING.
D. THE REVERSE SHALL OCCUR ON THE RISE IN SPACE
TEMPERATURE.
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
LIFE SAFETY AND FIRE PROTECTION:
STANTON ENGINEERING SERVICES
10280 OLD COLUMBIA RD
STE 275
COLUMBIA, MD 21046
(410) 290-9301
PROFESSIONAL SEAL:
Richmond VA Medical Center (RICVAMC) 1201 Broad Rock Blvd Richmond, VA 23249
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
ARCHITECT:
CB DESIGN GROUP
11720 BELTSVILLE DR
SUITE 350
CALVERTON, MD 20705
443-388-7351
ARCHITECTURE & MEP:
RAYMOND ENGINEERING
1601 SUMMIT AVE
RICHMOND, VA 23230
804-726-9540
05/20/2022
652-20121
ANCH
RENOVATION OF OLD DIALYSIS
AREA 2H
CONSTRUCTION BID SET
MECHANICAL CONTROLS
M-801
-2
M -8
/1
/2
.p
| Sheets |
| M-001 - MECHANICAL GENERAL NOTES AND DESIGN CRITERIA |
| M-002 - MECHANICAL ABBREVIATIONS AND LEGENDS |
| MD-101 - LEVEL 1 MECHANICAL DEMOLITION PLAN |
| MP-101 - MECHANICAL PIPING PLAN |
| M-101 - LEVEL 1 MECHANICAL FLOOR PLAN |
| M-501 - MECHANICAL DETAILS |
| M-601 - MECHANICAL SCHEDULES |
| M-801 - MECHANICAL CONTROLS |
File details come from the government source that posted it. Updated .