Plumbing.pdf
PDF 657 KB Posted
- Solicitation number
- 25-B-127LL
- Issued by
- Volusia County, Florida
About this file
The provided document is a plumbing design file for the Volusia County Tax Collector's Office renovation project located in DeLand, Florida. The plumbing drawings, dated 05.15.2025, include a plumbing legend, sheet list, and a first-level plumbing plan, prepared by Silling Architects and Ingenuity Engineers. The plan details new plumbing work for the interior renovation, featuring a comprehensive plumbing fixture schedule that specifies a single compartment sink (S-1) with detailed specifications, including a Lustertone 25x21 single compartment sink with an Elkay model DLR252210.
The plumbing design covers various rooms including break room, offices, mechanical spaces, toilets, and service areas, with specific plumbing connections noted such as 1/2" cold water lines, 1/2" hot water lines, and 2" sanitary and vent connections. The drawings include a pipe support detail and extensive legends and abbreviations to guide installation, with annotations for connection points, pipe directions, and verification requirements. The project appears to be a comprehensive interior renovation of the existing Tax Collector's office, with precise plumbing infrastructure modifications to support the building's functional requirements.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROD
CLEVIS
SHIELD
PIPE
INSULATION
DRAWING NUMBER
SEAL
S
RACH ITECTS
TITLE
DATE
LOCATION
OWNER
PROJECT
605 E. Robinson Street Suite 630
Orlando, Florida 32801 Office 321.296.8100 silling.com
CA# 26308 I24027.00
5/16/2025 8:51:25 AMAutodesk Docs://VOLUSIA-TC Office Deland/VCTCO-Plum.rvt
PLUMBING LEGEND,
NOTES, SCHEDULES,
ABBREVIATIONS &
DETAILS
P0.001
Volusia County Tax Collector
Thomas C Kelley Administration Center 123 W. Indiana Avenue Deland, Florida 32720
Volusia County Tax Collector - Deland Office Renovation
Eric S Cepull PE 64750
05.15.2025
IE - PLUMBING SHEET LIST
Sheet Number Sheet Name Project Issue Date Project Status Current Revision Current Revision Date Current Revision Description Sheet Discipline
P0.001 PLUMBING LEGEND, NOTES, SCHEDULES, ABBREVIATIONS & DETAILS 05.15.2025 ISSUE FOR PERMIT PLUMBING
P1.101 FIRST LEVEL PLAN PLUMBING 05.15.2025 ISSUE FOR PERMIT PLUMBING
Grand total: 2
TRAPFIXTURE TYPE
FIXTURE
NO.
WASTE
CONN.
VENT
CONN.
C.W.
CONN.
H.W.
CONN.
MANUFACTURER
/ MODEL #
DESCRIPTION
PLUMBING FIXTURE SCHEDULE
SCALE: NTSP0.001
1 PIPE SUPPORT DETAIL
PLUMBING LEGEND
SANITARY UNDERGROUND
HOT WATER SUPPLY
COLD WATER SUPPLY EXISTING
SANITARY
SANITARY EXISTING
GREASE
GREASE UNDERGROUND
GREASE EXISTING
COLD WATER SUPPLY
HOT WATER SUPPLY EXISTING
HOT WATER RETURN
HOT WATER RETURN EXISTING
GAS
GAS UNDERGROUND
GAS EXISTING
OIL RECOVERY
CONDENSATE DRAIN
CONDENSATE DRAIN EXISTING
FORCE MAIN
CITY PRESSURE WATER
120° HOT WATER SUPPLY
140° HOT WATER SUPPLY
160° HOT WATER SUPPLY
CD
CD
CD
CTY
FM
G
G
EX G
GR
GR
OR
120°
140°
160°
SAN
SAN
EX SAN
VENT
STORM
VENT EXISTING
STORM UNDERGROUND
STORM EXISTING
SECONDARY STORM
SECONDARY STORM UNDERGROUND
SECONDARY STORM EXISTING
ST
ST
EX ST
V
EX V
SEC
SEC
EX SEC
HOSE BIBB
POINT OF REMOVAL FOR DEMOLITION
NEW POINT OF CONNECTION TO EXISTING
FLOOR DRAIN
PIPE UP
PIPE DOWN/TEE DOWN
DIRECTION OF FLOW IN PIPE
BALL VALVE
CAPPED LINE
CHECK VALVE, HORIZONTAL SWING
SHOCK ABSORBER
2-WAY EXTERIOR CLEANOUT
FLOOR SINK
CLEANOUT
CONDENSATE DRAIN UNDERGROUND
A AMPERES
ACS AUTOMATIC CONTROL SYSTEM
AD ACCESS DOOR
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
APRROX APPROXIMATELY
AP ACCESS PANEL
ARCH ARCHITECTURAL
AUTO AUTOMATIC
AUX AUXILIARY
BFF BELOW FINISH FLOOR
BFP BACKFLOW PREVENTER
BG BELOW GRADE
BHP BRAKE HORSEPOWER
BLDG BUILDING
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
BWV BACK WATER VALVE
CCP CENTRAL CONTROL PANEL
CD CONDENSATE DRAIN
CLG CEILING
CO CLEAN-OUT
COMB COMBINATION
COMPR COMPRESSOR
COND CONDENSATE OR CONDENSER
CONT CONTINUATION
CMU CONCRETE MASONRY UNIT
CU FT CUBIC FEET
CU IN CUBIC INCHES
CW COLD WATER
D DRAIN LINE
DW DIRECT WASTE
EL ELEVATION
EQ EQUAL
EXST OR (E) EXISTING
EXP EXPANSION
ESEW EMERGENCY SHOWER / EYEWASH
°F DEGREE FAHRENHEIT
ECO EXTERIOR CLEAN-OUT
FC FLEXIBLE CONNECTION
FCO FLOOR CLEAN-OUT
FG FINISHED GRADE
FIN FL FINISHED FLOOR
FLA FULL LOAD AMPERES
FM FORCE MAIN
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FPM FEET PER MINUTE
FPS FEET PER SECOND
GA GAUGE
GAL GALLONS
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H HEIGHT
HB HOSE BIBB
H2O WATER
HD HEAD
HORIZ HORIZONTAL
HP HORSEPOWER
HW HOT WATER SUPPLY
HWR HOT WATER RETURN
HR HOUR
ABBREVIATIONS
Hz FREQUENCY
IE OR INV INVERT ELEVATION
ID INSIDE DIAMETER
IN INCH OR INCHES
INSUL INSULATION
IPS IRON PIPE SIZE
IW INDIRECT WASTE
KW KILOWATT
LB/HR POUNDS PER HOUR
LBS POUNDS
LIN FT LINEAR FEET
MAX MAXIMUM
MBH THOUSANDS, BTUH
MC MECHANICAL CONTRACTOR
MIN MINIMUM
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO. NUMBER
NTS NOT TO SCALE
OD OUTSIDE DIAMETER
OR OIL RECOVERY
P OR PRESS PRESSURE
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
PSI POUNDS PER SQUARE INCH
PSIA PSI ABSOLUTE
PSIG PSI GAUGE
PVC POLYVINYL CHLORIDE
R RISE
RD ROOF DRAIN
REQ'D REQUIRED
RL RAIN LEADER
RM ROOM
RPM REVOLUTIONS PER MINUTE
RV RELIEF VALVE
SAN SANITARY
SMH STORM MANHOLE
SPEC SPECIFICATION
SCW SOFT COLD WATER
SF SQUARE FEET
ST STORM
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
V VENT LINE
VLV VALVE
VTR VENT THRU ROOF
W WIDTH
W/ WITH
W/O WITHOUT
WC WATER COLUMN
WCO WALL CLEAN-OUT
WG WATER GAUGE
WP WORKING PRESSURE
LUSTERTONE 25X21 SINGLE COMPARTMENT SINK, 10" DEEP, 18 GAUGE, 3 HOLE, TYPE 304 SS, SELF RIMMING, T&S B2731 SINGLE CONTROL LEVER HANDLE, DAYTON D1125 BASKET STRAINER.
PROVIDE TAILPIECE, P-TRAPS, SUPPLIES, STOPS AND ESCUTCHEONS.
S-1 SINK 2" 1-1/2" 1-1/2" 1/2" 1/2"
SS SINGLE
ELKAY
DLR252210
REVISIONS
A A
B B
G G
H H
J J
D D
E E
F F
S-1
3 3/4" CW
BREAK
ROOM
OFFICE
CASH
IT
118MECHANICAL
STAIR
HALL
STORAGE
HALL
ELEC
IT
STORAGE
PERMITTING
HALL
TOILET
TOILET
CHECK-IN
STAFF
CHECK-IN
ENTRY
WAITING A
WAITING B
SERVICE
TESTING
CUSTOMER
SERVICE
HALL
HALL
HALL
4 1/2" HW
NIC
1/2" CW TO
COFFEE MAKER
2" SAN
2" V
/4
DRAWING NUMBER
SEAL
S
RACH ITECTS
TITLE
DATE
LOCATION
OWNER
PROJECT
605 E. Robinson Street Suite 630
Orlando, Florida 32801 Office 321.296.8100 silling.com
CA# 26308 I24027.00
5/16/2025 8:51:36 AMAutodesk Docs://VOLUSIA-TC Office Deland/VCTCO-Plum.rvt
FIRST LEVEL PLAN
PLUMBING
P1.101
Volusia County Tax Collector
Thomas C Kelley Administration Center 123 W. Indiana Avenue Deland, Florida 32720
Volusia County Tax Collector - Deland Office Renovation
Eric S Cepull PE 64750
05.15.2025
1/8" = 1'-0"P1.101
1 1ST LEVEL - New Work Plumbing
CONNECT NEW 2" SAN BELOW SLAB TO EXISTING SAN LINE
LOCATED IN BATHROOM AREA. FIELD VERIFY EXACT SIZE AND
LOCATION OF PIPE PRIOR TO CONSTRUCTION.
CONNECT NEW 2" VENT ABOVE CEILING TO EXISTING VENT LINE IN
BATHROOM AREA. FIELD VERIFY EXACT SIZE AND LOCATION OF
PIPE PRIOR TO CONSTRUCTION.
CONNECT NEW 3/4" COLD WATER W/ SHUT-OFF VALVE ABOVE
CEILING TO EXISTING COLD WATER LINE IN RESTROOM AREA.
FIELD VERIFY EXACT SIZE AND LOCATION OF PIPE PRIOR TO
CONSTRUCTION.
CONNECT NEW 1/2" HOT WATER W/ SHUT-OFF VALVE ABOVE
CEILING TO EXISTING HOT WATER LINE IN RESTROOM AREA. FIELD
VERIFY EXACT SIZE AND LOCATION OF PIPE PRIOR TO
CONSTRUCTION.
1/2" CW DN.
1/2" CW AND HW DN.
REFERENCE NOTES
REVISIONS
| P0.001 - PLUMBING LEGEND, NOTES, SCHEDULES, ABBREVIATIONS & DETAILS |
| P1.101 - FIRST LEVEL PLAN PLUMBING |