OH0000CL_Bricker Federal Building Parking Facility Asbestos Notification Letter.pdf

PDF 18 KB Posted

Attached to
GC Services for the Bricker USBC Backfill Project Federal contract opportunity
Solicitation number
47PF0022R0038
Issued by
General Services Administration Public Buildings Service Region 5

About this file

This notification letter informs prospective contractors of the presence of asbestos containing materials and presumed asbestos containing materials in the Bricker Federal Building and Parking Facility in Columbus, Ohio. The letter specifies that asbestos containing material is present in the following forms and locations: mastic throughout the building totaling 8,850 square feet; duct sealant in all ducts and air handling units throughout the building and penthouse totaling 14,000 square feet; sink undercoating on all sinks throughout the building with an undefined quantity; drywall systems in the elevator lobby on the second floor totaling 1,000 square feet; insulating cement at the ends of pipes in the parking garage totaling 1,000 square feet; chilled water tank insulation in the air handling room totaling 250 cubic feet; roofing materials on the roof totaling 30,000 square feet; mirror mastics on restroom mirrors with an undefined quantity; and fire doors throughout the building with an undefined quantity. Prospective contractors are advised to contact Anna Vanko with any questions.

The related federal contract opportunity is solicitation number 47PF0022R0038 for GC services for the Bricker USBC Backfill Project from the General Services Administration Public Buildings Service Region 5.

View the file

Other files for this federal contract opportunity

Other files attached to GC Services for the Bricker USBC Backfill Project, newest first.
File Type Posted
Amend 0006 RFP47PF0022R0038 SF30.pdf PDF
Amend 0006 47PF0022R0038 RFIs.pdf PDF
REVISED_Bricker Supplemental 1442 8 2 2023.pdf PDF
Amend 0005 47PF0022R0038 RFIs.pdf PDF
OH0208CL - Bricker FB - Phase I Environmental Site Assessment 2006.pdf PDF
Amend 0005 RFP47PF0022R0038 SF30.pdf PDF
REVISED_Bricker Supplemental 1442 Pricing Sheet.pdf PDF
Amend 0003 47PF0022R0038 RFIs.pdf PDF
Amend 0003 RFP47PF0022R0038 SF30.pdf PDF
Amend 0004 RFP47PF0022R0038 SF30.pdf PDF
Amend 0003 47PF0022R0038 RFIs.pdf PDF
Amend 0003 RFP47PF0022R0038 SF30.pdf PDF
Amend 0002 RFP47PF0022R0038 SF30.pdf PDF
47PF0022R0038 PreProposal sign In Sheet.pdf PDF
Bricker USBC GC PreProposal Agenda.pdf PDF
Amend 0001 RFP47PF0022R0038 RFIs.pdf PDF
Amend 0001 RFP47PF0022R0038 SF30.pdf PDF
Compiled_Bricker_CD_95.pdf PDF
GSA527-21.pdf PDF
Past Performance Questionnaire.docx DOCX document
Bricker Supplemental 1442 Pricing Sheet.pdf PDF
Bricker Backfill - GSA Pricing Guidance Table Rev05 w.CT edits.comments V3.xlsx XLSX spreadsheet
PreProposal Conference Registration.pdf PDF
OH20230078 04 14 2023.pdf PDF
Spec_Bricker_CD_95.pdf PDF
RFP47PF0022R0038 SF1442.pdf PDF
SF24-16e (4).pdf PDF
47PF0022R0038 GC_Solicitation_March_2023 (2).pdf PDF
47PF0022R0038 GC Reps and Certs March 2023 (1).pdf PDF
Supplemental Pricing Sheet.pdf PDF
Individual Model_Subk_Plan - Jan 2023 - Final_508.docx DOCX document
Supplemental Docs_Bricker_CD_95.pdf PDF
47PF0022R0038 GC_Agreement_March_2023 (1).pdf PDF
Show all 33

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date: 06/21/2023

Prospective Contractors (bidders), Pursuant to the Code of Federal Regulations all building owners are required to provide notification of the presence, location, and quantity of asbestos containing materials (ACM) and presumed asbestos containing materials (PACM) in their facilities. This notification is provided as a safeguard, to ensure prospective contractors (bidders) are aware of this information.

Asbestos containing material is present in the Bricker Federal Building and Parking Facility

(OH0000CL) in the following forms, locations, and quantities:

Type Location Quantity

Mastic Throughout Building 8850 sf

Duct Sealant All Ducts and AHUs Throughout Building and Penthouse 14000 sf

Sink Undercoating All Sinks Throughout Building Undefined 1

Drywall Systems Elevator Lobby (2nd Floor) 1000 sf

Insulating Cement at Ends of Pipes Parking Garage 1000 sf

Chilled Water Tank Insulation2 Air Handling Room 250 cf

Roofing Materials2 Roof 30000 sf

Mirror Mastics2 Restroom Mirrors Undefined1

Fire Doors2 Throughout Building Undefined1

If you have any questions, please contact Anna Vanko at anna.vanko@gsa.gov.

1 Quantity was not defined at the time of the most recent survey.

2 Denotes material was not tested at the time of the most recent survey. Testing is not feasible in some cases as it would result in damage to the material or its structural components. In other cases, the material or area may not have been accessible. As such, the material must be presumed to be ACM based on its characteristics, age or other technical factors. Material is presumed to be ACM to ensure appropriate precautions and methods are employed when contemplating or executing activity that may disturb the material.