NORTH_ARFF_KITCHEN_DRAWINGS-BID.pdf
PDF 3 MB Posted
- Attached to
- North ARFF Station 2 Kitchen Remodel
- Solicitation number
- 26-043-ITB
- Issued by
- Bell County, Kentucky
About this file
This document set consists of architectural and engineering drawings for the North ARFF Kitchen Remodel project at Cincinnati/Northern Kentucky International Airport, prepared by Emboss Design, P.S.C. for the Kenton County Airport Board. The project involves a comprehensive kitchen renovation at the North ARFF Fire Station located at 81 Clay Drive, Hebron, Kentucky, including demolition of existing cabinetry, countertops, and finishes; installation of new kitchen cabinets with solid surface countertops and backsplash; replacement of ceiling systems with 2x2 vinyl-faced suspended panels in the kitchen and 2x4 suspended acoustical panels in adjacent areas; new lighting controls and fixtures; new aluminum storefront door with tempered glass; and relocation of existing equipment including refrigerators, ice machine, and coffee dispenser. The drawings are dated for bidding and permitting as of June 30, 2026, with a pre-bid meeting and site visit scheduled for Thursday, July 30, 2026 at 10:00 am. Questions are due by 11:59 pm on August 10, 2026, with answers posted by August 13, 2026, and bids due by 2:00 pm on August 20, 2026.
The project scope includes contractor-furnished and contractor-installed work, owner-furnished items (range, refrigerators, microwave), and coordination with multiple trades including electrical, mechanical, plumbing, and fire protection systems. Electrical work includes new branch circuiting, lighting controls with occupancy sensors and dimming capability, temporary kitchen power provisions via a new 100-amp panel, and reconnection of existing equipment through the Ansul fire suppression system. The temporary kitchen requires a contactor system to disable power during emergency calls, with three cord reel drops for refrigerator power. Fire protection modifications maintain 100% wet pipe sprinkler coverage with heads removed, saved, and reinstalled. Plumbing work includes a new stainless steel farmer sink with supporting piping. The design accommodates existing structural elements including radiators, exhaust hoods, and fire extinguisher cabinets. Procurement coordination is required for cabinet field measurements and sizing to accommodate existing equipment and plumbing connections.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OVERALL FIRST FLOOR PLAN
A100
A1 FIRST FLOOR PLAN
SCALE: 1/8" =1'-0"
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
D D
ES
IG
N S
IN
C O
R
PO
R A
TE
D H
ER
EI
N , A
S A N
I N
ST
R U M
EN
T
O F
PR
O
FE
SS
IO
N
A L
SE
R V
IC
E, I S
TH
E
PR
O
PE
R
TY
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
A N
D I S
N O
T
TO
B E
U
SE
D I N
IS
SU
E DATE DESCRIPTIONNO.
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
W H
O
LE
O R I N
P A R T
FO
R A
N Y
O
TH
ER
P
R O
JE
C T, W
IT
H O
U T
TH
E
W R
IT
TE
N
A U
TH
O R
IZ
A
TI
O N
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
C O
PY
R
IG
H T
-2
6:
E
M
BO
SS
D
ES
IG
N , P
.S .C
A
LL
R
IG
H
TS
R
ES
ER
V
ED
P:
\2
Pr oj ec ts \P r2
6-
N or th
A R
FF
K itc he n R em od el \0
6- D ra w in gs
\6 .0
3- C
D
2026-021
4/20/26 30% REVIEW SET
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
5/15/26 60% REVIEW SET
CONSTRUCTION NOTES
6/1/26 90% REVIEW SET
6/30/26 BIDDING & PERMIT
AutoCAD SHX Text
DINING
AutoCAD SHX Text
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
COMMUNICATIONS
AutoCAD SHX Text
AutoCAD SHX Text
SHIFT OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 109B
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR.
AutoCAD SHX Text 143A
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text 123A
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
AutoCAD SHX Text
SCBA
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
STOR.
AutoCAD SHX Text
AutoCAD SHX Text
EMS
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR.
AutoCAD SHX Text 138A
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
AutoCAD SHX Text
WORK ROOM
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
COMP
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
APPARATUS BAY
AutoCAD SHX Text
AutoCAD SHX Text
FOAM
AutoCAD SHX Text
AutoCAD SHX Text T.O.G.
AutoCAD SHX Text
AutoCAD SHX Text
SHOP
AutoCAD SHX Text
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text 102A
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text 102B
AutoCAD SHX Text
RANGE BY OWNER
AutoCAD SHX Text
ICE MACHINE BY OWNER
AutoCAD SHX Text
EX. EYE WASH
AutoCAD SHX Text
REFRIGERATORS BY OWNER
AutoCAD SHX Text
3'-0" TABLE W/ MICROWAVES BY OWNER
AutoCAD SHX Text A101
AutoCAD SHX Text A6
AutoCAD SHX Text 10A
AutoCAD SHX Text 10A
AutoCAD SHX Text 10A
AutoCAD SHX Text 10A
AutoCAD SHX Text 10A
AutoCAD SHX Text 01 EXISTING ITEMS 1A. 1B. EXISTING VENDING MACHINES TO REMAIN. REMOVE/REINSTALL AS REQ'D TO COMPLETE WORK 1C. EXISTING REFRIGERATORS. RELOCATE TO NEW LOCATION 1D. EXISTING ICE MACHINE. RELOCATE TO NEW LOCATION 1E. EXISTING COFFEE DISPENSER. RELOCATE TO NEW LOCATION 1F. EXISTING FIRE EXTINGUISHER CABINET TO REMAIN 1G. EXISTING RADIATOR TO REMAIN 1H. EXISTING EXHAUST TO REMAIN 1J. EXISTING TABLE AND CHAIRS WILL BE REMOVED AND REINSTALLED BY OWNER 1K. EXISTING WALL MOUNTED TV TO REMAIN 1L. EXISTING DISHWASHER. REMOVE/REINSTALL AS REQ'D TO COMPLETE WORK 1M. RELOCATE CUP DISPENSER AS DIRECTED BY OWNER 1N. REMOVE/REINSTALL FIRE EXTINGUISHER AS REQ'D TO COMPLETE WORK 1P. REMOVE/REINSTALL SIGN AS REQ'D TO COMPLETE WORK 1Q. REMOVE/REINSTALL MISC. WALL MOUNTED PICTURES, SIGNS, ETC. AS REQ'D TO COMPLETE WORK 02 DEMOLITION DEMOLITION 2A. DEMO WALL 2B. DEMO BASE/WALL CABINETS, COUNTER, AND ASSOCIATED SINK 2C. DEMO CERAMIC TILE AND BASE 2D. DEMO SOAP AND PAPER TOWEL DISPENSERS 2E. RELOCATE ANSUL CONTROLS. SEE MEP DRAWINGS FOR ADDL INFO. 2F. DEMO WINDOW BLINDS. NEW BLINDS WILL BE BY OWNER 2G. DEMO CARPET 2H. DEMO RANGE 2J. REMOVE DOOR - FRAME TO REMAIN 2K. DEMO SUSPENDED ACOUSTICAL PANEL CEILING 08 OPENINGS OPENINGS 8A. NEW ALUMINUM STOREFRONT DOOR (3'-0"x7-8"± FIELD VERIFY) INEXISTING FRAME WITH TEMPERED, TINTED, INSULATING LOW-E GLASS. TEMPERED, TINTED, INSULATING LOW-E GLASS. FINISH TO MATCH EXISTING. PROVIDE HINGES, PUSH BAR/PULL, LATCH SET, THRESHOLD, SWEEP, WEATHERSTRIPPING, AND ELECTRIC STRIKE TO MATCH EXISTING. RECONNECT TO EXISTING MATRIX ACCESS CONTROL SYSTEM 10 SPECIALTIES SPECIALTIES 10A. 4'-0" HIGH CORNER GUARD 12 FURNISHING 12A. NEW RANGE - SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR 12B. NEW REFRIGERATOR - SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR
AutoCAD SHX Text 906 Monmouth Street, AutoCAD SHX Text Newport, KY 41071
AutoCAD SHX Text EmbossDesign.com
AutoCAD SHX Text (859)431-8612
AutoCAD SHX Text X
DEMOLITION PLAN
ENLARGED FLOOR PLAN
A101
A1 PARTIAL DEMOLITION PLAN
SCALE: 1/8" =1'-0"
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
D D
ES
IG
N S
IN
C O
R
PO
R A
TE
D H
ER
EI
N , A
S A N
I N
ST
R U M
EN
T
O F
PR
O
FE
SS
IO
N
A L
SE
R V
IC
E, I S
TH
E
PR
O
PE
R
TY
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
A N
D I S
N O
T
TO
B E
U
SE
D I N
IS
SU
E DATE DESCRIPTIONNO.
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
W H
O
LE
O R I N
P A R T
FO
R A
N Y
O
TH
ER
P
R O
JE
C T, W
IT
H O
U T
TH
E
W R
IT
TE
N
A U
TH
O R
IZ
A
TI
O N
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
C O
PY
R
IG
H T
-2
6:
E
M
BO
SS
D
ES
IG
N , P
.S .C
A
LL
R
IG
H
TS
R
ES
ER
V
ED
P:
\2
Pr oj ec ts \P r2
6-
N or th
A R
FF
K itc he n R em od el \0
6- D ra w in gs
\6 .0
3- C
D
2026-021
4/20/26 30% REVIEW SET
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
A6 ENLARGED FLOOR PLAN
SCALE: 1/4" =1'-0"
5/15/26 60% REVIEW SET
J6 PARTIAL CEILING DEMOLITION PLAN
SCALE: 1/8" =1'-0"
CONSTRUCTION NOTES
ROOM FINISH SCHEDULE
6/1/26 90% REVIEW SET
6/30/26 BIDDING & PERMIT
AutoCAD SHX Text
VENDING
AutoCAD SHX Text
VENDING
AutoCAD SHX Text
ICE
AutoCAD SHX Text
COFFEE
AutoCAD SHX Text
RELOCATED
AutoCAD SHX Text
DINING
AutoCAD SHX Text
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
COMMUNICATIONS
AutoCAD SHX Text
AutoCAD SHX Text
SHIFT OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text A102
AutoCAD SHX Text J11
AutoCAD SHX Text A7
AutoCAD SHX Text J7
AutoCAD SHX Text A102
AutoCAD SHX Text G7
AutoCAD SHX Text A102
AutoCAD SHX Text G7
AutoCAD SHX Text
OPP. HAND
AutoCAD SHX Text
DW
AutoCAD SHX Text
DW
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DISPENSER
AutoCAD SHX Text
EX. FEC
AutoCAD SHX Text
EX. FE
AutoCAD SHX Text 9'-4"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 10A
AutoCAD SHX Text 10A
AutoCAD SHX Text 12A
AutoCAD SHX Text 12B
AutoCAD SHX Text 12B
AutoCAD SHX Text 12B
AutoCAD SHX Text 10A
AutoCAD SHX Text 10A
AutoCAD SHX Text 10A
AutoCAD SHX Text 8A
AutoCAD SHX Text
DINING
AutoCAD SHX Text
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
COMMUNICATIONS
AutoCAD SHX Text
AutoCAD SHX Text
SHIFT OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 109B
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR.
AutoCAD SHX Text 143A
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text 123A
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
DORM
AutoCAD SHX Text
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
AutoCAD SHX Text
SCBA
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
STOR.
AutoCAD SHX Text
AutoCAD SHX Text
EMS
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR.
AutoCAD SHX Text 138A
AutoCAD SHX Text
STAIR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
AutoCAD SHX Text
WORK ROOM
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
COMP
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text 102A
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text 102B
AutoCAD SHX Text 2A
AutoCAD SHX Text 1C
AutoCAD SHX Text 1C
AutoCAD SHX Text 1C
AutoCAD SHX Text 2A
AutoCAD SHX Text 1F
AutoCAD SHX Text 1F
AutoCAD SHX Text 1G
AutoCAD SHX Text 1G
AutoCAD SHX Text 2E
AutoCAD SHX Text 2F
AutoCAD SHX Text 1J
AutoCAD SHX Text 1H
AutoCAD SHX Text 1K
AutoCAD SHX Text 1L
AutoCAD SHX Text 2G
AutoCAD SHX Text 2G
AutoCAD SHX Text 2H
AutoCAD SHX Text 1B
AutoCAD SHX Text 1B
AutoCAD SHX Text 1D
AutoCAD SHX Text 1E
AutoCAD SHX Text 1M
AutoCAD SHX Text 1N
AutoCAD SHX Text 1P
AutoCAD SHX Text 2B
AutoCAD SHX Text 2B
AutoCAD SHX Text 2B
AutoCAD SHX Text 2B
AutoCAD SHX Text 2B
AutoCAD SHX Text 2C
AutoCAD SHX Text 2C
AutoCAD SHX Text 1Q
AutoCAD SHX Text 1Q
AutoCAD SHX Text 1Q
AutoCAD SHX Text 1K
AutoCAD SHX Text 2C
AutoCAD SHX Text 2C
AutoCAD SHX Text 2C
AutoCAD SHX Text 2C
AutoCAD SHX Text 2C
AutoCAD SHX Text 2D
AutoCAD SHX Text
EX. CARPET TO REMAIN
AutoCAD SHX Text 2J
AutoCAD SHX Text 2K
AutoCAD SHX Text 2K
AutoCAD SHX Text 2K
AutoCAD SHX Text 2K
AutoCAD SHX Text
DEMO GYP. BD. SOFFIT
AutoCAD SHX Text
DEMO SUSP. ACT. CLG.
AutoCAD SHX Text
DEMO SUSP. ACT. CLG.
AutoCAD SHX Text
EX. GYP. BD. SOFFIT TO REMAIN
AutoCAD SHX Text
EX. GYP. BD. CLG. TO REMAIN
AutoCAD SHX Text 01 EXISTING ITEMS 1A. 1B. EXISTING VENDING MACHINES TO REMAIN. REMOVE/REINSTALL AS REQ'D TO COMPLETE WORK 1C. EXISTING REFRIGERATORS. RELOCATE TO NEW LOCATION 1D. EXISTING ICE MACHINE. RELOCATE TO NEW LOCATION 1E. EXISTING COFFEE DISPENSER. RELOCATE TO NEW LOCATION 1F. EXISTING FIRE EXTINGUISHER CABINET TO REMAIN 1G. EXISTING RADIATOR TO REMAIN 1H. EXISTING EXHAUST TO REMAIN 1J. EXISTING TABLE AND CHAIRS WILL BE REMOVED AND REINSTALLED BY OWNER 1K. EXISTING WALL MOUNTED TV TO REMAIN 1L. EXISTING DISHWASHER. REMOVE/REINSTALL AS REQ'D TO COMPLETE WORK 1M. RELOCATE CUP DISPENSER AS DIRECTED BY OWNER 1N. REMOVE/REINSTALL FIRE EXTINGUISHER AS REQ'D TO COMPLETE WORK 1P. REMOVE/REINSTALL SIGN AS REQ'D TO COMPLETE WORK 1Q. REMOVE/REINSTALL MISC. WALL MOUNTED PICTURES, SIGNS, ETC. AS REQ'D TO COMPLETE WORK 02 DEMOLITION DEMOLITION 2A. DEMO WALL 2B. DEMO BASE/WALL CABINETS, COUNTER, AND ASSOCIATED SINK 2C. DEMO CERAMIC TILE AND BASE 2D. DEMO SOAP AND PAPER TOWEL DISPENSERS 2E. RELOCATE ANSUL CONTROLS. SEE MEP DRAWINGS FOR ADDL INFO. 2F. DEMO WINDOW BLINDS. NEW BLINDS WILL BE BY OWNER 2G. DEMO CARPET 2H. DEMO RANGE 2J. REMOVE DOOR - FRAME TO REMAIN 2K. DEMO SUSPENDED ACOUSTICAL PANEL CEILING 08 OPENINGS OPENINGS 8A. NEW ALUMINUM STOREFRONT DOOR (3'-0"x7-8"± FIELD VERIFY) INEXISTING FRAME WITH TEMPERED, TINTED, INSULATING LOW-E GLASS. TEMPERED, TINTED, INSULATING LOW-E GLASS. FINISH TO MATCH EXISTING. PROVIDE HINGES, PUSH BAR/PULL, LATCH SET, THRESHOLD, SWEEP, WEATHERSTRIPPING, AND ELECTRIC STRIKE TO MATCH EXISTING. RECONNECT TO EXISTING MATRIX ACCESS CONTROL SYSTEM 10 SPECIALTIES SPECIALTIES 10A. 4'-0" HIGH CORNER GUARD 12 FURNISHING 12A. NEW RANGE - SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR 12B. NEW REFRIGERATOR - SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR
AutoCAD SHX Text 906 Monmouth Street, AutoCAD SHX Text Newport, KY 41071
AutoCAD SHX Text EmbossDesign.com
AutoCAD SHX Text (859)431-8612
AutoCAD SHX Text X
VESTIBULE 100 FLOOR: WALK-OFF CPT TILE & CERAMIC TILE BORDER (MATCH WALK-OFF CPT TILE & CERAMIC TILE BORDER (MATCH EXISTING BORDER PATTERN) BASE: 6" CERAMIC TILE 6" CERAMIC TILE WALLS: PAINT PAINT CEILING: 2x4 SUSPENDED ACOUSTICAL PANEL CEILING 2x4 SUSPENDED ACOUSTICAL PANEL CEILING CORRIDOR 109 FLOOR: CERAMIC TILE CERAMIC TILE BASE: 6" CERAMIC TILE 6" CERAMIC TILE WALLS: PAINT PAINT CEILING: 2x4 SUSPENDED ACOUSTICAL PANEL CEILING 2x4 SUSPENDED ACOUSTICAL PANEL CEILING VESTIBULE 131 FLOOR: CERAMIC TILE CERAMIC TILE BASE: 6" CERAMIC TILE 6" CERAMIC TILE WALLS: PAINT PAINT CEILING: 2x4 SUSPENDED ACOUSTICAL PANEL CEILING 2x4 SUSPENDED ACOUSTICAL PANEL CEILING CORRIDOR 132 FLOOR: WALK-OFF CPT TILE & CERAMIC TILE BORDER (MATCH WALK-OFF CPT TILE & CERAMIC TILE BORDER (MATCH EXISTING BORDER PATTERN) BASE: 6" CERAMIC TILE 6" CERAMIC TILE WALLS: PAINT PAINT CEILING: 2x4 SUSPENDED ACOUSTICAL PANEL CEILING 2x4 SUSPENDED ACOUSTICAL PANEL CEILING KITCHEN 134 FLOOR: CERAMIC TILE CERAMIC TILE BASE: 6" CERAMIC TILE 6" CERAMIC TILE WALLS: PAINT PAINT CEILING: 2x2 SUSPENDED VINYL FACED CEILING PANELS 2x2 SUSPENDED VINYL FACED CEILING PANELS DINING 135 FLOOR: CERAMIC TILE CERAMIC TILE BASE: 6" CERAMIC TILE 6" CERAMIC TILE WALLS: PAINT PAINT CEILING: 2x4 SUSPENDED ACOUSTICAL PANELS2x4 SUSPENDED ACOUSTICAL PANELS
REFLECTED CEILING PLAN
A102
A1 REFLECTED CEILING PLAN
SCALE: 1/4" =1'-0"
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
D D
ES
IG
N S
IN
C O
R
PO
R A
TE
D H
ER
EI
N , A
S A N
I N
ST
R U M
EN
T
O F
PR
O
FE
SS
IO
N
A L
SE
R V
IC
E, I S
TH
E
PR
O
PE
R
TY
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
A N
D I S
N O
T
TO
B E
U
SE
D I N
IS
SU
E DATE DESCRIPTIONNO.
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
W H
O
LE
O R I N
P A R T
FO
R A
N Y
O
TH
ER
P
R O
JE
C T, W
IT
H O
U T
TH
E
W R
IT
TE
N
A U
TH
O R
IZ
A
TI
O N
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
C O
PY
R
IG
H T
-2
6:
E
M
BO
SS
D
ES
IG
N , P
.S .C
A
LL
R
IG
H
TS
R
ES
ER
V
ED
P:
\2
Pr oj ec ts \P r2
6-
N or th
A R
FF
K itc he n R em od el \0
6- D ra w in gs
\6 .0
3- C
D
2026-021
4/20/26 30% REVIEW SET
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
A7 ELEVATION
SCALE: 3/8" =1'-0"
J7 ELEVATION
SCALE: 3/8" =1'-0"
J11 ELEVATION
SCALE: 3/8" =1'-0"
G7 ELEVATION
SCALE: 3/8" =1'-0"
5/15/26 60% REVIEW SET
6/1/26 90% REVIEW SET
6/30/26 BIDDING & PERMIT
AutoCAD SHX Text
LOCKABLE FULL HEIGHT PLASTIC LAMINATE CABINET W/ ADJ. SHELVING
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text W2430
AutoCAD SHX Text W2430
AutoCAD SHX Text B24
AutoCAD SHX Text B24
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
EXIST.
AutoCAD SHX Text
COFFEE
AutoCAD SHX Text
DISP.
AutoCAD SHX Text
REF
AutoCAD SHX Text
REF
AutoCAD SHX Text
REF
AutoCAD SHX Text
MICRO
AutoCAD SHX Text
MICRO
AutoCAD SHX Text W3342
AutoCAD SHX Text
EX. SOFFIT
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text B30
AutoCAD SHX Text B30
AutoCAD SHX Text B33
AutoCAD SHX Text W3024
AutoCAD SHX Text W3024
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text
FIELD MEASURE PRIOR TO ORDERING CABINETS
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text
SOLID SURFACE COUNTER W/ 4' BACKSPLASH
AutoCAD SHX Text
FILLER
AutoCAD SHX Text 9'-4"
AutoCAD SHX Text
P. LAM. MICROWAVE SHELF
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
SB36
AutoCAD SHX Text
DISHWASHER
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DISHWASHER
AutoCAD SHX Text
CABINET TO ACCOMMODATE "FARMER" SINK. COORD. SIZE W/ PLUMBING CONTR.
AutoCAD SHX Text
S.S. "FARMER" SINK
AutoCAD SHX Text
B18 BLIND CORNER W/
AutoCAD SHX Text
SOAP DISPENSER SUPPLIED BY OWNER FOR G.C. INSTALL
AutoCAD SHX Text W2442
AutoCAD SHX Text W3618
AutoCAD SHX Text W2442
AutoCAD SHX Text W3042
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text
SOLID SURFACE COUNTER
AutoCAD SHX Text
REV-A-SHELF BLIND CORNER
AutoCAD SHX Text 7'-11"/8'-0"±
AutoCAD SHX Text
OPTIMIZER HARDWARE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
REINSTALL
AutoCAD SHX Text
REINSTALL
AutoCAD SHX Text
EXISTING EXHAUST HOOD
AutoCAD SHX Text W3642
AutoCAD SHX Text B30
AutoCAD SHX Text B30
AutoCAD SHX Text W2442
AutoCAD SHX Text
NEW RANGE
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text
SOLID SURFACE COUNTER
AutoCAD SHX Text
EX. S.S. WALL PANEL TO REMAIN - CLEAN
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text B30
AutoCAD SHX Text
DB30
AutoCAD SHX Text
PLASTIC LAMINATE CABINET W/ ADJ. SHELVING
AutoCAD SHX Text
STAINLESS STEEL COUNTER @ ISLAND ONLY
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text B30
AutoCAD SHX Text
BASE BID: PAINT EXISTING GYP. BD. CLG.
AutoCAD SHX Text 2x4 SUSPENDED ACOUSTICAL PANEL CEILING ARMSTRONG #933
AutoCAD SHX Text GRID LOCATION & HEIGHT TO MATCH EXISTING TO MAINTAIN EXISTING SPRINKLER & HVAC DEVICE LOCATIONS
AutoCAD SHX Text
EX. EXHAUST HOOD
AutoCAD SHX Text
NEW GYP. BD. SOFFIT @ 8'-0"±TO ALIGN W/ EX. SOFFITS TO REMAIN - PAINTPAINT
AutoCAD SHX Text 2x2 VINYL FACED SUSPENDED GYPSUM PANEL CEILING
AutoCAD SHX Text GRID LOCATION & HEIGHT TO MATCH EXISTING TO MAINTAIN EXISTING SPRINKLER & HVAC DEVICE LOCATIONS
AutoCAD SHX Text
EX. GYP. BD. SOFFIT TO REMAIN - PAINT
AutoCAD SHX Text GRID LOCATION & HEIGHT TO MATCH EXISTING TO MAINTAIN EXISTING SPRINKLER & HVAC DEVICE LOCATIONS
AutoCAD SHX Text
ALTERNATE 1: PAINT EXISTING GYPSUM BOARD CEILING
AutoCAD SHX Text ALTERNATE 1: 2x4 SUSPENDED ACOUSTICAL PANEL CEILING ARMSTRONG #933
AutoCAD SHX Text ALTERNATE 1: 2x4 SUSPENDED ACOUSTICAL PANEL CEILING ARMSTRONG #933
AutoCAD SHX Text
ALTERNATE 1: PAINT EXISTING GYP. BD. CLG.
AutoCAD SHX Text
NO CEILING WORK
AutoCAD SHX Text 906 Monmouth Street, AutoCAD SHX Text Newport, KY 41071
AutoCAD SHX Text EmbossDesign.com
(859)431-8612
SD
UON
EM
CFOI
OFOI
CFCI
OFCI
J
DESCRIPTION
S
OS
POWER SUPPLY/CONTROL FOR AUDIO/VISUAL DEVICES
SLASH THROUGH ANY DEVICE INDICATES MOUNTING
ABOVE COUNTERTOP 2" ABOVE BACKSPLASH, OR AT
48" WHERE NO COUNTER IS PRESENT
VS
LV
FILLED CENTER BAR INDICATES INTEGRAL GROUND
FAULT PROTECTION (GFCI)
CONTRACTOR FURNISHED OWNER INSTALLED
CONTRACTOR FURNISHED CONTRACTOR INSTALLED
OWNER FURNISHED OWNER INSTALLED
OWNER FURNISHED CONTRACTOR INSTALLED
PHOTO-ELECTRIC SMOKE DETECTOR
MAIN CONTROL PANEL CENTRAL PROCESSING
UNIT (CPU)
LIGHT SWITCH:GENERAL PURPOSE
6'-6'' TO
TOP
UNLESS OTHERWISE NOTED
INDICATES EMERGENCY POWER
46"
ABBREVIATIONS
POWER OUTLETS
DUPLEX RECEPTACLE
QUADRUPLEX RECEPTACLE
JUNCTION BOX, CEILING OR WALL
OCCUPANCY OR VACANCY SENSOR, CEILING MOUNT
LOW VOLTAGE SWITCH ON OFF WITH ZONES
CLG
46"
46"
1'-6"
1'-6"
1'-6"
CLG
S
M O
U N
T
IN
G H
E
IG
H T
(T O
C E
N T
E R
O F
B O
X
D R
A W
IN
G
S
Y M
B O
L
ADDRESSABLE RELAY MODULE R
CONDUIT CONCEALED IN WALLS OR IN CEILING
SPACE: ARROW(S) INDICATE(S) HOME RUN & #
OF CIRCUITS: HASHMARKS INDICATE # OF
CONDUCTORS. DASHED LINE INDICATES
CONDUIT BELOW FLOOR.
PANELBOARD, SURFACE OR FLUSH MOUNTED,
HATCHING INDICATES EMERGENCY
EQUIPMENT TAG, REFER TO EQUIPMENT SCHEDULE
AS NOTED
MISCELLANEOUS
DISCONNECT SWITCH
TRANSFORMER
TAGGED NOTE
CONDUIT PATH
5'-0"
6'-6'' TO TOP
C A
B L
IN
G C
O N
D U
C T
O R
S
O F
O I
C A
B L
IN
G
C O
N D
U C
T O
R S
O
F C
I
C O
N D
U
IT
R
O U
G H
-I N
O
F O
I
IT
E
M U
S E
D O
N P
R O
J E
C T
D E
V
IC
E S
O
F C
I
D E
V
IC
E S
C
F C
I
SYSTEM D
E
V
IC
E S
O
F O
I
SYSTEM
RESPONSIBILITY
MATRIX
SYSTEM RESPONSIBILITY GENERAL NOTES:
A. CMTA IS NOT RESPONSIBILE FOR ASSIGNING SCOPE(S) OR WORK. THE INTENT OF
CONTRACTOR IN THIS MATRIX IS TO SEPERATE OWNER PROVIDED ITEMS FROM THE
GENERAL CONTRACTOR / CONSTRUCTION MANAGER. THE GC OR CM SHALL BE
RESPONSIBLE FOR A COMPLETE SCOPE OF WORK.
B. REFER TO VENDOR DRAWINGS FOR COMPLETE SCOPE OF WORK RELATING TO
VENDOR-FURNISHED EQUIPMENT. ALL WORK INDICATED ON VENDOR DRAWINGS SHALL
BE INCLUDED BY THE CONTRACTOR.
C. REFER TO ARCHITECTURAL DOOR HARDWARE SPECIFICATIONS FOR ACCESS CONTROL
DEVICE SPECIFICATIONS AND FURTHER REQUIREMENTS.
D. PROVIDE BACKBOXES AND CONDUIT WITH PULL-STRINGS FOR ALL SYSTEMS.
CONTRACTOR SHALL VERIFY BACKBOX SIZES, CONDUIT, ETC. AND EXACT
INSTALLATION LOCATIONS/REQUIREMENTS WITH SUCCESSFUL VENDORS OF ALL
SYSTEMS PRIOR TO CONSTRUCTION.
E. AT ALL SYSTEMS EQUIPMENT CABINET/TERMINAL BOARD LOCATIONS, CONTRACTOR
SHALL PROVIDE SIZE AND NUMBER OF CONDUIT STUB-OUTS TO CABLE PATHS AS
REQUIRED BY SYSTEM VENDORS, TERMINATE CONDUITS AT CABINETS/ON
BACKBOARDS AS REQUIRED. COORDINATE EXACT REQUIREMENTS WITH APPROPRIATE
VENDORS PRIOR TO CONSTRUCTION.
F. REFER TO SPECIFICATIONS FOR REQUIREMENTS APPLICABLE TO ALL SYSTEMS
INCLUDING CABLING, CABLE MANAGEMENT, INSTALLATION, GROUNDING, TESTING,
LABELING, ETC.
G. WHERE INDICATED AS CFCI, THE CONTRACTOR SHALL PROVIDE THE SYSTEM
COMPLETE, INCLUDING ALL ROUGH-INS, CABLING, DEVICES, POWER, ETC. THE
CONTRACTOR SHALL CONTACT THE LISTED VENDOR FOR PRICING PRIOR TO BID. ALL
SYSTEMS SHALL MATCH EXISTING FACILITY STANDARDS AND BE FULLY COMPATIBLE
WITH ANY EXISTING SYSTEMS. ALL SYSTEM VENDORS SHALL COORDINATE EXACT
SYSTEM REQUIREMENTS WITH OWNER PRIOR TO BID. NEW COMPONENTS SHALL BE
INTERCONNECTED WITH EXISTING SYSTEMS WHERE POSSIBLE. ALL NEW SYSTEM
DESIGNS AND PROGRAMMING SHALL BE COORDINATED WITH THE OWNER PRIOR TO
ORDERING. ALL PROGRAMMING SHALL BE INCLUDED AS REQUIRED BY THE OWNER.
PROVIDE 4 HOURS OF TRAINING FOR EACH SYSTEM.
SWITCHES
FIRE ALARM
E,EMINDICATES EMERGENCY POWER
NAC
FACP
AS SHOWNSOLID BOTTOM CABLE TRAY, SIZE AS NOTED
EQUIP-1
GROUND
NEUTRAL
PHASE
, J
#D/#V
#D
INTERMEDIATE DISTRIBUTION FRAME - REFERENCE
DATA SYSTEM SCHEMATICS AND DETAILS FOR
ADDITIONAL REQUIREMENTS
MAIN DISTRIBUTION FRAME - REFERENCE DATA
SYSTEM SCHEMATICS AND DETAILS FOR ADDITIONAL
REQUIREMENTS
WIRELESS ACCESS POINT WITH PROVISIONS FOR (1
DATA OUTLET FOR ANTENNA. PROVIDE A COMPLETE
DATA OUTLET WITH FACEPLATE ABOVE CEILING,
MOUNTED AT AN ACCESSIBLE HEIGHT NO MORE THAN
24" ABOVE CEILING. AT EACH OUTLET, PROVIDE A 20'
COIL OF CABLE AHEAD OF THE OUTLET FOR
ADJUSTMENT OF FINAL OUTLET LOCATION. THE
CONTRACTOR SHALL COORDINATE EXACT LOCATIONS
WITH THE OWNER AND ADJUST OUTLET LOCATIONS AT
SUBSTANTIAL COMPLETION TO ACCOMMODATE
OWNER'S WAP LOCATIONS. WAP'S ARE OWNER-
FURNISHED, OWNER-INSTALLED
WAP
DATA OUTLET : NUMBER BESIDE OUTLET
INDICATES NUMBER OF DATA JACKS
VOICE OUTLET : NUMBER BESIDE OUTLET
INDICATES NUMBER OF VOICE JACKS
COMBINATION OUTLET : NUMBER BESIDE OUTLET
INDICATES NUMBER OF DATA/VOICE JACKS
DATA / VOICE
1'-6"
1'-6"
1'-6"
#V
MDF
IDF
GROUND BUS BAR ON INSULATED STANDOFFS 2'-0''
DESCRIPTION M
O
U N
T
IN
G H
E
IG
H T
(T O
C E
N T
E R
O F
B O
X
D R
A W
M
B O
L
DESCRIPTION M
O
U N
T
IN
G H
E
IG
H T
(T O
C E
N T
E R
O F
B O
X
D R
A W
M
B O
L
DESCRIPTION
LV#S,
W H
IT
E
DEVICE
WALL SWITCHES
DEVICE COLOR
MATRIX
RECEPTACLE (NORMAL)
DEVICE COLOR GENERAL NOTES:
A. DEVICE PLATE TO MATCH DEVICE UNLESS NOTED OTHERWISE.
B. NOT ALL DEVICES MAYBE USED THAT ARE SHOWN.
C. IF DEVICE COLOR NOT DEFINED REFER TO SPECIFICATIONS.
DESCRIPTION
IV
O
R Y
R E
D
O R
A N
G E
B L
U E
Y E
L L O
W
C U
S T
O M
S T
A
IN
L E
S S
S T
E E
L
LEGEND
INDICATES SELECTED COLOR
INDICATES COLOR NOT AVAILABLE
INDICATES COLOR NOT SELECTED
LEGEND
INDICATES SELECTED SYSTEM
INDICATES NOT AVAILALBE
INDICATES NOT SELECTED
C O
N D
U
IT
R
O U
G H
-I N
O
F C
I
C O
N D
U
IT
R
O U
G H
-I N
C
F C
I
C A
B L
IN
G
C O
N D
U C
T O
R S
C
F C
I
P R
O G
R A
M M
IN
G
S
E T
U P
O
F O
I
P R
O G
R A
M M
IN
G
S
E T
U P
O
F C
I
P R
O G
R A
M M
IN
G
S
E T
U P
C
F C
I
ST
CONDUIT PATH UNDERNEATH RAISED FLOOR
FIRE ALARM
PUSHBUTTON STATION 46"
RECEPTACLE (UPS)
RECEPTACLE (ISOLATED GROUND)
T E
R M
IN
A
T
IO
N S
O
F C
I
T E
R M
IN
A
T
IO
N S
C
F C
I
T E
R M
IN
A
T
IO
N S
O
F O
I
LOW VOLTAGE SINGLE ZONE DIMMING SWITCH AS NOTED S M
S LV1-DLOW VOLTAGE SWITCH SINGLE ZONE DIMMER SWITCH 46"
SECURITY CCTV VIDEO SURVEILLANCE
REMOTE DOOR RELEASE PUSH-BUTTON 8" ACT RR
ELECTRICAL CORD REAL TO CEILING
S y c a m o re S t, S u it e
C in c in n a ti
O H
.4
.4
2026-021
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
D D
ES
IG
N S
IN
C O
R
PO
R A
TE
D H
ER
EI
N , A
S A N
I N
ST
R U M
EN
T
O F
PR
O
FE
SS
IO
N
A L
SE
R V
IC
E, I S
TH
E
PR
O
PE
R
TY
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
A N
D I S
N O
T
TO
B E
U
SE
D I N
W H
O
LE
O R I N
P A R T
FO
R A
N Y
O
TH
ER
P
R O
JE
C T, W
IT
H O
U T
TH
E
W R
IT
TE
N
A U
TH
O R
IZ
A
TI
O N
O F
EM
B O
SS
D
ES
IG
N , P
.S .C
C O
PY
R
IG
H T
-2
6:
E
M B O
SS
D
ES
IG
N , P
.S .C
A
LL
R
IG
H
TS
R
ES
ER
V
ED
IS
SU
E DATE DESCRIPTIONNO.
P
P ro je c ts
\P r2
-0
N o rt h A
R F
F K it c h e n R e m o d e l\ -D ra w in g s \6
.0 -C
D
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
6/30/26 BIDDING & PERMIT
906 Monmouth Street, Newport, KY 41071
EmbossDesign.com
(859)431-8612
E 0 0 0
E L E C T R I C A L L E G E N D
ELECTRICAL GENERAL NOTES:
A. EACH CONTRACTOR, PROPOSER, SUPPLIER AND/OR MANUFACTURER SHALL REFER TO ALL DOCUMENTS
PERTAINING TO THIS PROJECT AND COORDINATE ACCORDINGLY SO AS TO ENSURE ADEQUACY OF FIT, COMPLIANCE WITH SPECIFICATIONS, PROPER VOLTAGE AND CURRENT CHARACTERISTICS TO AVOID CONFLICT
WITH ANY OTHER BUILDINGS SYSTEMS. VERIFY SAME WITH SHOP DRAWINGS.
B. ADDITIONAL ELECTRICAL REQUIREMENTS MAY BE SHOWN ON PLANS FROM OTHER DISCIPLINES IN THIS SET. IT IS THE CONTRACTOR’S RESPONSIBILITY TO REVIEW ALL PLANS AND SPECIFICATIONS FOR A COMPLETE
UNDERSTANDING OF THE PROJECT REQUIREMENTS.
C. WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF ALL LOCAL, STATE, AND NATIONAL CODES.
INCLUDING BUT NOT LIMITED TO NFPA 70 (NEC), NFPA 72, INTERNATIONAL BUILDING CODES, ETC.
D. CONTRACTOR SHALL FOLLOW SEISMIC RESTRAINT AND DESIGN REQUIREMENTS CONTAINED IN LATEST ADOPTED STATE AND INTERNATIONAL BUILDING CODES, WITH ALL AMENDMENTS AS ADOPTED BY THE CURRENT LEGISLATION. REFER TO ELECTRICAL AND STRUCTURAL SPECIFICATIONS FOR ADDITIONAL INFORMATION.
E. ALL OFFSETS, TURNS, FITTINGS, TRIM, DETAIL, ETC. MAY NOT BE INDICATED, BUT SHALL BE PROVIDED AS REQUIRED. ADDITIONAL ALLOWANCES SHALL BE INCLUDED FOR SAME AT EACH PROPOSER’S DISCRETION.
F. INSTALL NO PIPING, CONDUIT, DUCTWORK, ETC. IN A LOCATION OR IN A MANNER WHICH WILL ALLOW FREEZING
OR THE COLLECTION OF CONDENSATION THEREON. IF IN DOUBT, CONTACT THE ENGINEER.
G. ADVISE THE ENGINEER OF ANY CONFLICTS, ERRORS, OMISSIONS, ETC. AT LEAST TEN DAYS PRIOR TO BID DATE, TO ALLOW CLARIFICATION BY WRITTEN ADDENDUM.
H. WHERE CONFLICTS ARE FOUND BETWEEN DRAWINGS, DETAILS, OR SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENT SHALL APPLY. NOTIFY ARCHITECT OF DISCREPANCY IN WRITING.
I. DEVIATION FROM SPECIFICATIONS OR PLANS REQUIRES PRIOR WRITTEN APPROVAL FROM THE ENGINEERS AND
MUST BE SUBMITTED IN WRITING NO LATER THAN TEN DAYS PRIOR TO THE BID DATE.
J. OBSERVE ALL APPLICABLE CODES, RULES AND REGULATIONS THAT MAY APPLY TO THE WORK UNDER THIS CONTRACT. (CITY, COUNTY, LOCAL, STATE, FEDERAL, MUNICIPALITY, UTILITY COMPANY, OSHA, ETC.).
K. MOUNTING HEIGHTS FOR WALL MOUNTED DEVICES INDICATED ABOVE FINISHED FLOOR ARE TO CENTER OF DEVICE UNO. MOUNTING HEIGHTS TO CEILING SUSPENDED DEVICES ARE TO BOTTOM OF DEVICE UNO.
L. INSTALL EQUIPMENT, MATERIALS, ETC. IN STRICT ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND DIRECTIONS. IF IN CONFLICT WITH THE DESIGN INDICATED IN CONTRACT DOCUMENTS, ADVISE THE
ENGINEER PRIOR TO INSTALLATION FOR CLARIFICATION.
M. THE PURPOSE AND INTENT OF ALL OF THE DOCUMENTS PERTAINING TO THIS PROJECT IS TO PROVIDE A COMPLETE, FUNCTIONAL, SAFE, LIKE-NEW FACILITY. ANYTHING LESS SHALL BE UNACCEPTABLE.
N. ALL SYSTEMS, EQUIPMENT AND MATERIALS ARE TO BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER.
WORK NOT MEETING THIS CRITERION SHALL BE REMOVED AND REINSTALLED SATISFACTORILY. FINAL DETERMINATION OF THE ACCEPTABILITY OF THE QUALITY OF WORK RESIDES WITH THE ENGINEER
O. ALL WORK, MATERIALS, EQUIPMENT, ETC. SHALL BE FULLY GUARANTEED FOR ONE FULL CALENDAR YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION AS DOCUMENTED BY THE ENGINEER, UNLESS LONGER WARRANTY
PERIODS FOR EQUIPMENT ARE SPECIFIED.
P. UNLESS OTHERWISE SPECIFIED OR INDICATED, ALL EQUIPMENT AND/OR MATERIALS WITHIN OCCUPIED SPACES OR EXPOSED TO VIEW ON THE BUILDING EXTERIOR SHALL BE PRIMED AND FINISHED SO AS TO COMPLEMENT ADJACENT SURFACE, UNLESS OTHERWISE NOTED. COORDINATE WORK AND COLORS WITH ARCHITECT.
Q. COORDINATE WITH ARCHITECTURAL FLOOR PLANS, ELEVATIONS AND CASEWORK DETAILS FOR LOCATION OF
ADDITIONAL RECEPTACLES, UTILITY OUTLETS, ELECTRICAL DEVICES, ETC.
R. CEILING-MOUNTED ELECTRICAL DEVICES SHALL BE CENTERED IN 2'X2' CEILING TILE AND INSTALLED CENTERED ON 2' DIMENSION OF 2'X4' TILE AND ON CENTERLINE OR A QUARTER POINT ON 4' DIMENSION.
S. ANY VIBRATING, OSCILLATING OR OTHER NOISE OR MOTION PRODUCING EQUIPMENT SHALL BE ISOLATED FROM SURROUNDING SYSTEMS IN AN APPROVED MANNER. NOISY OR STRUCTURALLY DAMAGING INSTALLATIONS SHALL BE SATISFACTORILY REPLACED OR REPAIRED AT THE INSTALLING CONTRACTORS' EXPENSE. THE FINAL DECISION ON THE SUITABILITY OF A PARTICULAR INSTALLATION'S ACCEPTABILITY SHALL BE THAT OF THE
ENGINEER.
T. PROVIDE DETAILED SHOP DRAWINGS TO ENGINEER PRIOR TO PURCHASING OR INSTALLING ANY EQUIPMENT U. DEVIATIONS IN SIZES, CAPACITIES, FIT, FINISH, ETC. FOR EQUIPMENT FROM THAT PRIME SPECIFIED SHALL BE
THE RESPONSIBILITY OF THE PURCHASER OF THAT EQUIPMENT. ANY PROVISIONS REQUIRED TO ACCOMMODATE A DEVIATION, WHETHER APPROVED BY THE ENGINEER OR NOT, SHALL BE THE RESPONSIBILITY
OF THE PURCHASER.
V. THE CONSTRUCTION MANAGER, GENERAL CONTRACTOR, OR WHOMEVER HOLDS THE PRIME CONTRACT(S) FOR THIS CONSTRUCTION IS RESPONSIBLE FOR THE COORDINATION, APPEARANCE, SCHEDULING AND TIMELINESS OF THE WORK OF ALL TRADES, CONTRACTORS, SUPPLIERS, INSTALLERS, ETC. POOR OR UNTIMELY WORK ON THE PART OF ANY SUBCONTRACTOR SHALL BE RESOLVED BY THE PARTY WHO ENGAGED THEM ON THIS
PROJECT.
W. WHERE MOUNTING HEIGHTS ARE NOT INDICATED OR ARE IN CONFLICT WITH ANY OTHER BUILDING SYSTEM, CONTACT THE ENGINEER BEFORE AFFECTING INSTALLATION. REFER ALSO TO ARCHITECTURAL INTERIOR AND EXTERIOR ELEVATIONS, CEILING HEIGHTS AND OTHER DETAILS OF THESE DOCUMENTS, AS APPLICABLE.
X. WHERE FIRE-RATED CEILING ASSEMBLIES ARE NOTED, PROVIDE UL-LISTED FIRE-RATED GYPSUM BOARD OR PRE-MANUFACTURED ENCLOSURES ABOVE LUMINAIRES, CEILING DEVICES, ETC. IN OR ON CEILING, AS
REQUIRED TO MAINTAIN CEILING RATINGS.
Y. COORDINATE THE LOCATION OF DRAINS, ELECTRICAL OUTLETS, GAS OUTLETS, ETC. WITH ALL CASEWORK, KITCHEN EQUIPMENT, MECHANICAL ROOM EQUIPMENT, ETC. PRIOR TO COMMENCING INSTALLATION. WORK NOT SO COORDINATED SHALL BE REMOVED AND PROPERLY INSTALLED AT THE EXPENSE OF THE RESPONSIBLE
CONTRACTOR(S).
Z. ALL ELECTRICAL COMPONENTS OR EQUIPMENT SHALL BE LISTED AND LABELED BY UNDERWRITER'S LABORATORIES OR OTHER APPROVED LISTING AGENCY. APPROVAL AND LABELING OF INDIVIDUAL COMPONENTS ON AN ASSEMBLY IS NOT ACCEPTABLE AS MEETING THIS REQUIREMENT, UNLESS WAIVED BY THE
ENGINEER IN WRITING.
AA. ALL WIRING SYSTEMS SHALL BE INSTALLED WITH A MINIMUM OF SPLICES. CONDUCTORS, WHETHER SINGLE OR MULTI-PAIR, SHALL BE INSTALLED CONTINUOUS INSOFAR AS POSSIBLE FROM TERMINAL POINT TO TERMINAL
POINT.
BB. NO CONDUIT, SUPPORTS, ETC. SHALL BE RUN THROUGH ACCESS CLEARANCES OF EQUIPMENT BY OTHER
TRADES (I.E. VAV BOXES). COORDINATE WITH ALL TRADES PRIOR TO CONSTRUCTION.
CC. ALL CONTRACTORS SHALL EXERCISE EXTREME CARE IN THE COURSE OF THEIR WORK SO AS TO ENSURE THAT THEY DO NOT INTERRUPT ANY EXISTING SERVICE OR SUB-SERVICE FOR SAFETY PURPOSES. PAY PARTICULAR ATTENTION TO THIS PRECAUTION RELATIVE TO NATURAL GAS AND ELECTRICAL LINES. VERIFY THE LOCATION, SIZE, TYPE, ETC. OF EACH UNDERGROUND OR OVERHEAD UTILITY. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL FEDERAL, STATE AND/OR LOCAL RULES, REGULATIONS, STANDARD AND SAFETY REQUIREMENTS. UTILITIES SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE MUNICIPALITY OR UTILITY COMPANY STANDARDS. IN ALL CASES, THE MOST STRINGENT REQUIREMENT SHALL APPLY.
DD. ALL SUPPORTS FOR EQUIPMENT, DEVICES OR FIXTURES SHALL BE UNIQUE, DIRECTLY FROM THE BUILDING STRUCTURE. DO NOT SUPPORT WORK FROM OTHER TRADES EQUIPMENT OR SUPPORTS WITHOUT WRITTEN
PERMISSION FROM THE ENGINEER AND CONSENT OF THE OTHER TRADE, IN WRITING.
EE. WHERE INTERRUPTING AN EXISTING UTILITY OR SERVICE DELIBERATELY OR ACCIDENTALLY, THE RESPONSIBLE CONTRACTOR SHALL WORK CONTINUOUSLY AS NEEDED TO RESTORE SAME, PROVIDING PREMIUM TIME AS
NEEDED.
FF. REFER TO ARCHITECTURAL WALL ELEVATIONS (WHERE GIVEN) FOR HEIGHTS AND MOUNTING RELATIONSHIP OF OUTLETS AND EQUIPMENT. IF IN DOUBT, CONTACT ENGINEER FOR DIRECTION PRIOR TO ROUGH IN.
GG. AS APPLICABLE, REFER TO ARCHITECTURAL PHASING PLANS AND PHASING BOUNDARIES ON THESE DRAWINGS FOR SEQUENCING OF WORK, FULL EXTENT OF AREAS INVOLVED, EXTENT OF CEILING WORK, ETC. PROVIDE TEMPORARY CONNECTIONS FOR CIRCUITS AND WORK AS REQUIRED TO MAINTAIN SEQUENCE OF THE WORK
FROM PHASE TO PHASE.
HH. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED FOR HIS WORK. ALL CUTTING AND PATCHING SHALL BE IN ACCORDANCE WITH THE ARCHITECT'S STANDARDS FOR SUCH WORK.
II. ALL WORK SHALL BE CONCEALED UNLESS SPECIFICALLY INDICATED TO BE EXPOSED, OR REQUIRED TO BE EXPOSED. IF IN DOUBT, CONTACT THE ENGINEER FOR CLARIFICATIONS PRIOR TO INSTALLING ANY SUCH WORK.
JJ. WHERE BACKBOXES ARE LOCATED IN THE SAME VERTICAL CHANNEL/STUD SPACE ON OPPOSITE SIDES OF THE SAME WALL, PROVIDE SOUND-INSULATING PUTTY AROUND BOXES AS REQUIRED TO ELIMINATE SOUND
TRANSMISSION FROM ROOM TO ROOM.
KK. JUNCTION BOXES LOCATED ABOVE ACCESSIBLE CEILINGS SHALL BE LOCATED NO MORE THAN 36” ABOVE CEILING LEVEL. LABEL EACH BOX IN AREA OF WORK WITH A PERMANENT MARKER OR IN ACCORDANCE WITH
SPECIFICATIONS, WHICHEVER IS MORE STRINGENT.
LL. ALL MATERIALS FURNISHED AND ALL WORK INSTALLED SHALL COMPLY WITH THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODES, NATIONAL FIRE CODES OF THE NATIONAL FIRE PROTECTION ASSOCIATION, THE REQUIREMENTS OF LOCAL UTILITY COMPANIES, AND WITH THE REQUIREMENTS OF ALL GOVERNMENTAL AGENCIES OR DEPARTMENTS HAVING JURISDICTION. IF ANY CONFLICTS OR DISCREPANCIES OCCUR THE MOST
STRINGENT SHALL APPLY.
MM. DO NOT SCALE FROM DRAWINGS, AS PRINTING DISTORTS SCALE. WORK SHALL BE LAID OUT FROM
DIMENSIONED DRAWINGS, OR DIMENSIONS SUPPLIED TO THE CONTRACTOR.
NN. NOISY WORK, WORK OUTSIDE CONSTRUCTION BARRIERS, WORK IN OCCUPIED AREAS, ETC. SHALL BE PERFORMED AFTER HOURS OR ON WEEKENDS. COORDINATE EXACT SCHEDULING WITH FACILITY PRIOR TO
CONSTRUCTION.
OO. REFER TO ARCHITECTURAL PLANS FOR PHASING REQUIREMENTS. WORK SHALL BE COMPLETED IN PHASES PER THE PHASING PLAN AND AS COORDINATED WITH OWNER AND GENERAL CONTRACTOR. PROVIDE ALL REQUIRED INCREMENTAL INSPECTIONS, CERTIFICATIONS, ETC. AND ALL TEMPORARY SERVICES AS REQUIRED BY OWNER
TO ACCOMPLISH THE PHASING PLAN.
ELECTRICAL DEMOLITION NOTES:
A. DOTTED LINES INDICATE ITEMS FOR REMOVAL (UON) AND THIN SOLID LINES INDICATE
EXISTING ITEMS TO REMAIN.
B. THE CONTRACTOR SHALL MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT
CONTAIN DEVICES OR EQUIPMENT THAT ARE TO REMAIN. WHEN DEMOLITION OF AN
ELECTRICAL DEVICE (OR CIRCUIT) IS INDICATED ON THE DRAWINGS: THE CONTRACTOR
SHALL ENSURE THAT OTHER DEVICES OR EQUIPMENT "UPSTREAM" OR "DOWNSTREAM"
ON THE CIRCUITS SHALL REMAIN IN "PRE- DEMOLITION" WORKING ORDER. "LEFT-OVER"
CIRCUIT BREAKERS SHALL REMAIN, BE SWITCHED TO OFF POSITION, AND BE LABELED AS
SPARES IN THEIR PANELS. PROVIDE NEW TYPEWRITTEN DIRECTORIES FOR ALL PANELS
AFFECTED.
C. LOCATIONS OF DEVICES, CONNECTIONS, ETC., INDICATED ON THIS DRAWING WERE
TAKEN FROM VARIOUS SOURCES. THEY ARE DIAGRAMMATIC ONLY AND ARE SUBJECT TO
VARIATION FROM EXISTING CONDITIONS. CERTAIN EXISTING ELEMENTS MAY NOT BE
INDICATED AT ALL. THE CONTRACTOR PROPOSING TO DO ANY PART OF THE WORK
INDICATED HEREON SHALL VISIT THIS SITE AND DETERMINE TO HIS SATISFACTION THAT
THEY MAY COMPLETE ALL WORK REQUIRED FOR THE BID WHICH HE PROPOSES.
D. REMOVE ALL ASSOCIATED BACKBOXES, CONDUIT AND CONDUCTORS FOR DEVICES /
FIXTURES / ETC. BEING REMOVED (BACK TO SOURCE), WHETHER INDICATED OR NOT
(UON). CONTRACTOR SHALL PATCH AND REPAIR ANY EXISTING WALLS, FLOORS OR
CEILINGS WHERE DEVICES ARE SHOWN TO BE REMOVED (PATCH AND REPAIR TO
RECEIVE NEW FINISHES - SEE ARCHITECTURAL PLANS).
E. COORDINATE DISPOSAL OF ALL FIXTURES, DEVICES, ETC. (INDICATED FOR DEMOLITION)
WITH OWNER. TURN OVER ITEMS REMOVED TO OWNER AT THEIR OPTION.
F. COORDINATE WITH OTHER TRADES FOR THE REMOVAL AND/OR RELOCATION OF
ELECTRICAL DEVICES AND CONNECTIONS ASSOCIATED WITH THEIR EQUIPMENT.
G. PROVIDE TEMPORARY EMERGENCY EXIT LIGHTS AT CONSTRUCTION BARRIERS AS
REQUIRED.
H. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS / CEILINGS AS REQUIRED
WHERE DEVICES ARE BEING REMOVED OR INSTALLED.
I. UNUSED/ABANDONED CONDUCTORS DISCOVERED ABOVE ACCESSIBLE CEILINGS SHALL
BE REMOVED IN ACCORDANCE WITH NEC REQUIREMENTS.
J. EXISTING ELECTRICAL SYSTEMS IN CONFLICT WITH CONSTRUCTION SHALL BE
RELOCATED TO PERMIT INSTALLATION OF DEVICES AND EQUIPMENT SHOWN ON PLANS.
K. DEVICES INDICATED WITH AN ''R'' SHALL BE RELOCATED. REMOVE, PROTECT, AND
REINSTALL IN NEW LOCATION INDICATED ON NEW WORK PLANS. INTERCEPT AND
EXTEND ALL EXISTING CABLING TO NEW LOCATION. CLEAN AND RE-LAMP RELOCATED
LUMINAIRES.
L. ALL EXISTING PANELS AFFECTED BY THIS CONTRACTOR'S WORK SHALL BE PROVIDED
WITH NEW TYPE-WRITTEN PANEL DIRECTORIES AND INSERT SLEEVES. PANEL
DIRECTORIES SHALL NOT USE ROOM NAMES OR NUMBERS FROM THESE DRAWINGS.
DIRECTORIES SHALL BE DETAILED AND COORDINATED WITH OWNER'S SUITE NUMBERS,
FINAL ROOM NUMBERS, IT RACK NAMES, WORKSTATION DESIGNATIONS, ETC. UNUSED
BREAKERS SHALL BE IN OFF POSITION.
GENERAL NOTES (LIGHTING):
A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND CASEWORK
DETAILS FOR EXACT LOCATIONS OF ALL WALL AND CEILING MOUNTED ELECTRICAL
DEVICES.
B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS INDICATED ON THE
FLOOR PLANS, WITH A MAXIMUM OF THREE (3) BRANCH CIRCUITS PER HOMERUN. EACH
BRANCH CIRCUIT SHALL BE PROVIDED WITH A DEDICATED NEUTRAL
CONDUCTOR. DEDICATED NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT
CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME CONDUIT WITH THOSE
INDICATED, CONTRACTOR SHALL DERATE ALL CURRENT CARRYING CONDUCTORS PER
N.E.C. #310.15(B)(3), AND UPSIZE CONDUIT AS REQUIRED PER N.E.C. #300.17 AND ANNEX C. MULTIWIRE BRANCH CIRCUITS AS DEFINED IN N.E.C #100 / 210.4 (CIRCUITS SHARING A
COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.
C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES, ETC. IN
AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS WITH BLACK LETTERING.
GENERAL NOTES (POWER):
A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND CASEWORK
DETAILS FOR EXACT LOCATIONS OF ALL WALL AND CEILING MOUNTED ELECTRICAL
DEVICES.
B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS INDICATED ON THE
FLOOR PLANS, WITH A MAXIMUM OF THREE (3) BRANCH CIRCUITS PER HOMERUN. EACH
BRANCH CIRCUIT SHALL BE PROVIDED WITH A DEDICATED NEUTRAL
CONDUCTOR. DEDICATED NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT
CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME CONDUIT WITH THOSE
INDICATED, CONTRACTOR SHALL DERATE ALL CURRENT CARRYING CONDUCTORS PER
NEC 310.15(B)(3), AND UPSIZE CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX
C. MULTIWIRE BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A
COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.
C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES, ETC. IN
AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS WITH BLACK LETTERING.
MARK INSIDES OF ALL DEVICE BOXES WITH PANEL AND CIRCUIT NUMBER.
D. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS SHALL BE
COORDINATED WITH MECHANICAL AND PLUMBING CONTRACTORS TO ENSURE ACCESS
AND WORKING CLEARANCE IS MAINTAINED PER NEC. NOTIFY OTHER TRADES OF
REQUIRED CLEARANCE AREAS TO AVOID ROUTING OF OTHER SYSTEMS IN THESE AREAS.
DO NOT INSTALL ELECTRICAL EQUIPMENT OVER EQUIPMENT NAMEPLATES OR ACCESS
PANELS OR THROUGH ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER
TRADES.
J
J
J
F F
J
J
F
J
FACP
DINING
KITCHEN
STORAGE
DORM
COMMUNICATIONS
SHIFT
OFFICE
DORM
DORM
DORM
STORAGE
VESTIBULE
131CORRIDOR
V
RR
WAP
AREA OF WORK
KITCHEN 134
STORAGE 133
DINING 135
6' 0"
DISPDW
REF
REF
REF
ICE
MW
MW
(E)LP1-1
(E)ELP1-1A
(E)ELP1-1
REF
EF-2
R
R R
E2
E1
E5 E13
E8
E3
E9
E9
E10
ELP1-1-18
E11
E11
ELP1-1-22
ELP1-1-30
ELP1-1-34
ELP1-1-14
ELP1-1-24
ELP1-1-10
ELP1-1A-37
ELP1-1A-29
ELP1-1A-31
ELP1-1A-33
LIGHTING CIRCUIT: ELP1-1-13
ELP1-1-16
ELP1-1-8
ELP1-1-28
ELP1-1-26
LP1-21
LP1-21
ELP1-1A-37
ELP1-1A-35
E21
E21
E21
E21
E4
E4
E4
E4
E4
E4
E4
E4
E4
E4
E12
E12
E12
E12
E12
E4
E15
NL
a a a a a b b c c c d c b a d
DW
R
ELP1-1-20
E2
EWC
ELP1-1-32
ELP1-1-32
ELP1-1-32
ELP1-1-32
ELP1-1-32
ELP1-1-32
R
E22
E11
E29
ELP1-1-32
ELP1-1-32
S y c a m o re S t, S u it e
C in c in n a ti
O H
.4
.4
2026-021
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
D D
ES
IG
N S
IN
C O
R
PO
R A
TE
D H
ER
EI
N , A
S A N
I N
ST
R U M
EN
T
O F
PR
O
FE
SS
IO
N
A L
SE
R V
IC
E, I S
TH
E
PR
O
PE
R
TY
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
A N
D I S
N O
T
TO
B E
U
SE
D I N
W H
O
LE
O R I N
P A R T
FO
R A
N Y
O
TH
ER
P
R O
JE
C T, W
IT
H O
U T
TH
E
W R
IT
TE
N
A U
TH
O R
IZ
A
TI
O N
O F
EM
B O
SS
D
ES
IG
N , P
.S .C
C O
PY
R
IG
H T
-2
6:
E
M B O
SS
D
ES
IG
N , P
.S .C
A
LL
R
IG
H
TS
R
ES
ER
V
ED
IS
SU
E DATE DESCRIPTIONNO.
P
P ro je c ts
\P r2
-0
N o rt h A
R F
F K it c h e n R e m o d e l\ -D ra w in g s \6
.0 -C
D
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
6/30/26 BIDDING & PERMIT
906 Monmouth Street, Newport, KY 41071
EmbossDesign.com
(859)431-8612
E 0 0 1
E L E C T R I C A L D E M O L I T I O N P L A N
TAGGED NOTES
E1 DISCONNECT AND PROTECT EXISTING ANSUL CABINET.
CABINET TO BE RELOCATED IN NEW WORK PHASE.
E2 DISCONNECT AND REMOVE EXISTING DISHWASHER, WIRING,
AND JUNCTION BOX BACK TO WALL. DISHWASHER TO BE
REINSTALLED IN NEW WORK PHASE. DEMOLISH SWITCH.
MAINTAIN SWITCH BACKBOX AND WIRING FOR
RECONNECTION IN NEW WORK PHASE.
E3 DISCONNECT AND REMOVE EXISTING GARBAGE DISPOSAL,
WIRING, AND JUNCTION BOX BACK TO WALL. DISPOSAL TO BE
REINSTALLED IN NEW WORK PHASE. DEMOLISH SWITCH.
MAINTAIN SWITCH BACKBOX AND WIRING FOR
RECONNECTION IN NEW WORK PHASE.
E4 DEMOLISH EXISTING DEVICE AND MAINTAIN BACKBOX. DEVICE
TO BE REPLACED IN NEW WORK PHASE.
E5 REWORK PULL CORD TO NEW ANSUL PANEL LOCATION.
REFER TO NEW PLANS.
E8 DEMOLISH EXISTING UNDER CABINET LIGHTING. DEMOLISH
LIGHT SWITCH. PRESERVE BACKBOX FOR NEW SWITCH.
MAINTAIN BRANCH WIRING FOR NEW UNDER CABINET
LIGHTING.
E9 DEMOLISH EXISTING KITCHEN ISLAND RECEPTACLES.
REWORK BRANCH WIRING TO CONNECT NEW RECEPTACLES
IN NEW KITCHEN ISLAND. SEE E101 FOR MORE INFORMATION.
E10 PROTECT AND REMOVE EXISTING LIGHT FIXTURE. RETAIN
CONTROLS AND BRANCH WIRING. NEW FIXTURE TO BE
REINSTALLED IN SAME LOCATION IN NEW WORK PHASE.
E11 REMOVE EXISTING LIGHT SWITCH AND WIRING.
E12 DEMOLISH EXISTING DATA DEVICE AND COVER WITH BLANK
PLATE.
E13 EXISTING GAS ESTOP BUTTON TO BE RELOCATED. SEE NEW
WORK PLAN ON SHEET E101 FOR MORE INFORMATION.
E15 VERIFY EXISTING RECEPTACLE IS WIRED THROUGH EXISTING
HOOD CONTACTOR. IF NOT, CONTRACTOR TO EXTEND
BRANCH WIRING THROUGH KITCHEN HOOD CONTACTOR.
RECEPTACLE TO BE DE-ENERGIZED UPON ACTIVATION OF THE
ANSUL SYSTEM.
E21 DEMOLISH EXISTING RECEPTACLE AND BACKBOX. MAINTAIN
WIRING FOR RECONNECTION TO NEW RECEPTACLE. REWORK
TO NEW LOCATION IN NEW WORK PHASE.
E22 DISCONNECT AND REMOVE EXISTING EXIT SIGN. PROTECT
FOR REINSTALLATION IN NEW WORK PHASE.
E29 HOOD IS EXISTING TO REMAIN.
SCALE:E001 1/4" = 1'-0"
1 ELECTRICAL KITCHEN DEMO PLAN
R
OS
OS
WAP
SD
J
WAP
SD
J
AREA OF WORK
VESTIBULE 100
CORRIDOR 109
CORRIDOR 132
VESTIBULE 131
E34
E34
E38
E38
E34
E35
E38
E34
E35
E34
E36
E34
E34
E34
E35
E34
E34
E22E36
E34E34E34
E34
E36
E35
EM STROBE
E37
E37
E37
E37
E37
E37
E37
E38E38E38
E38
E23
S y c a m o re S t, S u it e
C in c in n a ti
O H
.4
.4
2026-021
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
D D
ES
IG
N S
IN
C O
R
PO
R A
TE
D H
ER
EI
N , A
S A N
I N
ST
R U M
EN
T
O F
PR
O
FE
SS
IO
N
A L
SE
R V
IC
E, I S
TH
E
PR
O
PE
R
TY
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
A N
D I S
N O
T
TO
B E
U
SE
D I N
W H
O
LE
O R I N
P A R T
FO
R A
N Y
O
TH
ER
P
R O
JE
C T, W
IT
H O
U T
TH
E
W R
IT
TE
N
A U
TH
O R
IZ
A
TI
O N
O F
EM
B O
SS
D
ES
IG
N , P
.S .C
C O
PY
R
IG
H T
-2
6:
E
M B O
SS
D
ES
IG
N , P
.S .C
A
LL
R
IG
H
TS
R
ES
ER
V
ED
IS
SU
E DATE DESCRIPTIONNO.
P
P ro je c ts
\P r2
-0
N o rt h A
R F
F K it c h e n R e m o d e l\ -D ra w in g s \6
.0 -C
D
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
6/30/26 BIDDING & PERMIT
906 Monmouth Street, Newport, KY 41071
EmbossDesign.com
(859)431-8612
E 0 0 2
E L E C T R I C A L C O R R C E I L I N G P L A N
TAGGED NOTES
E22 DISCONNECT AND REMOVE EXISTING EXIT SIGN. PROTECT
FOR REINSTALLATION IN NEW WORK PHASE.
E23 REINSTALL SALVAGED EXIT SIGN.
E34 REMOVE EXISTING LIGHT FIXTURE. MAINTAIN EXISTING
CONTROLS AND BRANCH CIRCUITRY FOR NEW LIGHT FIXTURE.
REFER TO NEW WORK PLAN.
E35 EXISTING EXIT SIGN TO REMAIN.
E36 REMOVE EXISTING DEVICE. MAINTAIN EXISTING WIRING FOR
REINSTALLATION. REFER TO NEW WORK PLAN.
E37 INSTALL NEW LED 2X4 FLAT PANEL. WIRE TO EXISTING
CONTROLS AND BRANCH CIRCUITRY. CONTRACTOR TO
ENSURE THAT EXISTING CONTROLS ARE ADEQUATE TO
OPERATE LIGHT FIXTURES UNTIL THE REST OF THE
BUILDING'S LIGHT FIXTURES AND LIGHTING CONTROLS ARE
REPLACED AT A LATER DATE.
E38 INSTALL NEW 6 INCH DOWNLIGHT. MAINTAIN EXISTING
CONTROLS AND BRANCH CIRCUITRY. CONTRACTOR TO
ENSURE THAT EXISTING CONTROLS ARE ADEQUATE TO
OPERATE LIGHT FIXTURES UNTIL THE REST OF THE
BUILDING'S LIGHT FIXTURES AND LIGHTING CONTROLS ARE
REPLACED AT A LATER DATE.
R
SCALE:E002 1/4" = 1'-0"
1 ELEC VESTI 100 CEILING DEMO PLAN
SCALE:E002 1/4" = 1'-0"
2 ELEC VESTI 100 CEILING NEW PLAN
SCALE:E002 1/4" = 1'-0"
3 ELEC VESTI 131 CEILING DEMO PLAN
SCALE:E002 1/4" = 1'-0"
4 ELEC VESTI 131 CEILING NEW PLAN
SCALE:E002 1/4" = 1'-0"
5 ELECTRICAL CORRIDOR CEILING DEMO PLAN
SCALE:E002 1/4" = 1'-0"
6 ELECTRICAL CORRIDOR CEILING NEW PLAN
ALL SCOPE SHOWN ON THIS
SHEET IS FOR ALTERNATE 1.
J J
B L
AREA OF WORK
PROPOSED CONDUIT ROUTING FOR NEW TEMP KITCH PANEL
PART OF APPARATUS BAY 145
& THE PLAN LEFT MEZZANINE LEVEL ABOVE THE BAY
APPARATUS BAY
ELPM1A-40
LPM-1-9
LPM-1-9
ELPM-1A-11
CORD REEL CORD REEL
E6
(TYP)
E7-2TEMP KITCH
-1TEMP KITCH
-3,5TEMP KITCH
-4TEMP KITCH
-8TEMP KITCH
-7TEMP KITCH
-6TEMP KITCH
NEMA 14-50R
ELPM1A-40
ELPM-1A-11
ELPM-1A-11
EPO
E33
-10TEMP KITCH
E32
E32
E32
E32
MEZZANINE
STAIR
STAIR
(E)ELMP-1A
(E)ELPM-1
(E)LPM-1
LPM-1-3
ELPM-1-7
ELPM-1-7
ELPM-1-7
ELPM-1-7
ELPM-1-7)
ELPM-1-7
ELPM-1-7
ELP2-1-15
ELP2-1-13
ELP2-1-11
ELP2-1-11
(E)ELP2-1
(E)FARP
(E)LP2-1
STOR./ELEC.
RM
ELP2-1-9
(E) F-4
(E) F-5
(E) LC LD
(E) LL & LM
(E) LK & LN
TEMP KITCH
TEMP KITCH PNL
CONTACTOR
E26
E25
S y c a m o re S t, S u it e
C in c in n a ti
O H
.4
.4
2026-021
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
D D
ES
IG
N S
IN
C O
R
PO
R A
TE
D H
ER
EI
N , A
S A N
I N
ST
R U M
EN
T
O F
PR
O
FE
SS
IO
N
A L
SE
R V
IC
E, I S
TH
E
PR
O
PE
R
TY
O F
EM
BO
SS
D
ES
IG
N , P
.S .C
A N
D I S
N O
T
TO
B E
U
SE
D I N
W H
O
LE
O R I N
P A R T
FO
R A
N Y
O
TH
ER
P
R O
JE
C T, W
IT
H O
U T
TH
E
W R
IT
TE
N
A U
TH
O R
IZ
A
TI
O N
O F
EM
B O
SS
D
ES
IG
N , P
.S .C
C O
PY
R
IG
H T
-2
6:
E
M B O
SS
D
ES
IG
N , P
.S .C
A
LL
R
IG
H
TS
R
ES
ER
V
ED
IS
SU
E DATE DESCRIPTIONNO.
P
P ro je c ts
\P r2
-0
N o rt h A
R F
F K it c h e n R e m o d e l\ -D ra w in g s \6
.0 -C
D
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
15141312 161110987654321
A
D
B
C
E
F
G
H
J
K
L
M
6/30/26 BIDDING & PERMIT
906 Monmouth Street, Newport, KY 41071
EmbossDesign.com
(859)431-8612
E 1 0 0
E L E C T R I C A L T E M P O R A R Y P O W E R
TAGGED NOTES
E6 VERIFY ELECTRICAL REQUIREMENTS FOR TEMPORARY
KITCHEN STOVE WITH OWNER AND DESIGN TEAM PRIOR TO
INSTALLATION.
E7 ELECTRICAL CONTRACTOR SHALL INSTALL THREE (3) NEW
CORD REEL DROPS TO PROVIDE POWER FOR NEW
REFRIGERATORS IN THE TEMPORARY KITCHEN. THE CORD
REELS SHALL BE INSTALLED AT THE GARAGE CEILING, WITH
EXACT FINAL LOCATIONS DETERMINED IN THE FIELD. REFER
TO DETAIL 5 ON SHEET E200.
E25 PROVIDE 8P CONTACTOR WITH 120V, 1PH COIL TO DISABLE
POWER TO TEMPORARY KITCHEN WHEN EMERGENCY /
CRITICAL EVENT/CALL IS ACTIVE. PROVIDE WIRING AND
RELAY(S) AS REQUIRED TO CONNECT TO THE EXISTING FIRE
STATION ALTERING SYSTEM(S).
E26 PROVIDE TEMPORARY PANEL LOCATED ON MEZZANINE OF
BAY AREA. REFER TO SINGLE LINE AND KEY PLAN FOR
PROPOSED CONDUIT ROUTING.
E32 WIRE THIS CIRCUIT THROUGH THE CONTACTOR NEAR
SERVING PANEL. REFER TO KEYNOTE E25 AND DETAIL 4 ON
SHEET E200.
E33 REFER TO DETAIL 4 ON SHEET E200 FOR EPO CONNECTIONS.
COORDINATE WITH OWNER FOR EXACT PLACEMENT AND
INTEGRATION TO AUTOMATIC SHUTDOWN DURING DISPATCH
CALLS. PROVIDE WITH MANUAL RESET OF POWER TO
SHUTDOWN DEVICES AFTER THE DISPATCH CALL HAS BEEN
COMPLETED.
SCALE:E100 1/4" = 1'-0"
1 ELECTRICAL TEMPORARY KITCHEN PLAN
SCALE:E100 1/4" = 1'-0"
2 MEZZANINE LEVEL ELEC TEMP KITCHEN PLAN
DINING
KITCHEN
STORAGE
DORM
COMMUNICATIONS
CORRIDOR
J
J
F F
J
J
F
J
FACPJ
V
RR
OS
OS
OS
DINING
KITCHEN
STORAGE
DORM
COMMUNICATIONS
CORRIDOR
(E)LP1-1
(E)ELP1-1A
(E)ELP1-1
6' 0"
DISPDW
REF
REF
REF
ICE
MW
MW
REF
EF
R
R R
ELP1-1-18 ELP1-1-22
ELP1-1-30
ELP1-1-34
ELP1-1-14
ELP1-1-24
ELP1-1-10
ELP1-1A-29
ELP1-1A-31
ELP1-1A-33
ELP1-1-16
ELP1-1-8
ELP1-1-28
ELP1-1-26
LP1-21
LP1-21
ELP1-1A-35
E15
E14
E17
R
DW
ELP1-1-20
E20
E20
E20 E20
E20
E20
E20E20
E20
E20
E20
E20
E20
E18 E18 E18
E19
+64" AFF
+64" AFF
E20
-37ELP1-1A
-37ELP1-1
-39ELP1-1
E30
E30
E30
E30
E30
E30
E30
E30
-38ELP1-1A
E20
E20
AREA OF WORK
KITCHEN 134
STORAGE 133
DINING 135
LIGHTING CIRCUIT: ELP1-1-13
(TYP)
E16
NL
a a a a a b b d c b a d
LV1-D
LV1-D
F24 F24 F24
F24 F24 F24
F24 F24
F24
(E)LP1-1
(E)ELP1-1A
(E)ELP1-1
c c c
UC UC UC
UC
a
LV1-D
R
E23 c
UC
(TYP)
E27
E28 a b,c d c
UC
c
UC
c
UC c
UC
c
LV1-D
(TYP)
E16
OS CEILING MOUNTED OCCUPANCY SENSOR
A. LOW VOLTAGE CEILING MOUNTED OCCUPANCY SENSOR BASIS OF
DESIGN: nLIGHT nCM SERIES.
B. LIGHTING TO AUTOMATICALLY TURN ON TO 100% WHEN OCCUPANCY IS
DETECTED.
C. WHILE IN UNOCCUPIED MODE NORMAL AND EMERGENCY LIGHTING
SHALL TURN OFF.
D. LIGHTING SHALL HAVE AUTOMATIC SHUT-OFF OF LIGHTING WITHIN 15
MINUTES OF OCCUPANTS LEAVING.
E. WHERE LIFE-SAFETY LIGHTING CIRCUIT(S) ARE PRESENT, PROVIDE
UL924 DEVICE(S) TO REVERT LIGHTS TO 100% UPON FAILURE OF
NORMAL POWER.
ON / OFF
A. LOW VOLTAGE MANUAL CONTROL STATION WITH INDIVIDUAL BUTTONS AS
SHOWN ON DETAIL. BASIS OF DESIGN: nLIGHT nPODMA SERIES.
B. ADDITIONAL CONTROL INPUTS: VACANCY SENSOR, PHOTOCELL. REFER TO
FLOOR PLANS AND SEQUENCE OF OPERATIONS FOR ADDITIONAL CONTROL
REQUIREMENTS.
C. SWITCH REQUIREMENTS:
a. MANUAL ON BUTTON
b. MANUAL OFF BUTTON
c. RAISE BUTTON
d. LOWER BUTTON
$LV1-D LOW VOLTAGE ON/OFF, DIMMING CONTROL STATION
A. PROVIDE A STANDALONE LIGHTING CONTROL SYSTEM EQUAL TO nLIGHT BRANDS WITH ROOM
CONTROLLER TECHNOLOGY. REFER TO SPECIFICATIONS FOR ADDITIONAL ACCEPTABLE
MANUFACTURER.
B. PROVIDE FIRE-ALARM CONTROL/RELAY MODULE(S) AS REQUIRED TO MAKE LIGHTING CONTROL SYSTEM BRING ALL LIGHTING ON EGRESS PATHS TO 100% WHEN THE FIRE ALARM SYSTEM IS ACTIVATED.
C. INSTALL CONTROLLERS AND BRIDGES ABOVE ACCESSIBLE CEILING NEAR LUMINAIRE(S) TO BE CONTROLLED. PROVIDE CAD DRAWINGS INDICATING EXACT LOCATION OF CONTROL DEVICES AND
SUBMIT INFORMATION AS SHOP DRAWINGS FOR APPROVAL BY ENGINEER.
D. THE INTENTION IS TO PROVIDE A FULLY WIRED SYSTEM. WIRELESS AND/OR DEVICES THAT REQUIRE A
BATTERY ARE NOT ACCEPTABLE UNLESS SPECIFICALLY APPROVED BY THE ENGINEER.
E. CAT5, 5E, OR 6 NETWORK CABLE. NETWORK CABLE SHALL BE PLENUM RATED IF REQUIRED PER
SPECIFICATIONS AND /OR SITE CONDITIONS. MAXIMUM CABLE LENGTH PER ZONE 1500 FEET.
LIGHTING CONTROL GENERAL NOTES:
NETWORK CABLE USED TO
INTERCONNECT SWITCH TO
ROOM CONTROLLER
S y c a m o re S t, S u it e
C in c in n a ti
O H
.4
.4
2026-021
Cincinnati/Northern Kentucky International Airport
NORTH ARFF
FIRE STATION
Kitchen Remodel
TH
IS
D O
C U M
EN
T, A N
D T
H E
ID
EA
S A N
This is the start of the file's text. The full file is on GovTribe.