Node 2 Alarm.pdf
PDF 738 KB Posted
- Attached to
- Fire Alarm Removal and Replacement
- Solicitation number
- PE-92200-RFP-2026-000000061
- Issued by
- Fulton County, Georgia
About this file
This document is a fire alarm system nodal listing for Node 2 of a large public facility complex, detailing comprehensive fire detection and suppression monitoring across multiple buildings and levels. The system encompasses ten interconnected loops distributed across Buildings B, C, and OT (Office Tower), with over 1,000 individual alarm points including smoke detectors (ionization and photoelectric types), heat detectors (analog), water flow monitors, sprinkler tamper switches, elevator controls, door holders, strobes, speakers, and emergency communication systems. The facility includes the Georgia World Congress Center with multiple halls (C-Bldg with four levels, B-Bldg connector areas, and the Office Tower), the Thomas Murphy Ballroom, and various support facilities including laundries, commissaries, mechanical rooms, and parking structures. Each alarm point is precisely mapped with specific locations, device types, loop assignments, and descriptions of protected areas.
The Node 2 system represents a sophisticated integrated fire protection infrastructure managing hazards across diverse occupancy types including commercial kitchens with Ansul suppression systems, equipment rooms, storage facilities, atriums, and high-occupancy public spaces. The alarm monitoring includes integrated building systems such as HVAC air handler controls with smoke dampers, elevator recall and shutdown functions, automatic door closures, and pressurization controls for designated areas. The system documentation indicates active monitoring of critical infrastructure including diesel and electric fire pump operations, standpipe systems throughout 14+ stairwells, and water flow detection across multiple independent sprinkler zones. Extensive redundancy is built into the system with multiple detectors per area and backup monitoring modules throughout the facility, supporting life safety and property protection objectives across what appears to be a major metropolitan convention and hospitality complex.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NODE 2
11/18/2025 1
Alarm No. 101: Node 2: L01D01: Loop: 1 Device: 1
Display: NORMAL SMOKE (ION) DIESEL PUMP ROOM V000 M 046 Building: C Location: Detector located in the C-Bldg diesel fire pump room outside C1 dock next to fire dept. header Description: A Smoke Detector has gone off in this area.
Alarm No. 102: Node 2: L01D02: Loop: 1 Device: 2
Display: NORMAL SMOKE (ION) ELEC FIRE PUMP ROOM V000 M 059
Location: Detector located in the C-Bldg electric fire pump room located on C1 dock across from the laundry Description: A Smoke Detector has gone off in this area.
Alarm No. 103: Node 2: L01D03: Loop: 1 Device: 3
Display: NORMAL HEAT(ANALOG) ELEC FIRE PUMP ROOM V000 M 051
Location: Detector located in the C-Bldg electric fire pump room located on C1 dock across from the laundry Description: A Heat Detector has gone off in this area.
Alarm No. 104: Node 2: L01D04: Loop: 1 Device: 4
Display: NORMAL HEAT(ANALOG) TRASH COMPACTOR V000 M 053
Location: Detector located over the trash compactor at the southend of C-1 dock Description: A Heat Detector has gone off in this area.
Alarm No. 105: Node 2: L01D05: Loop: 1 Device: 5
Display: NORMAL HEAT(ANALOG) DRUM STORAGE SE DOCK V000 M 051
Location: Detector located in the storage room next to the trash compactor at the southend of C-1 dock Description: A Heat Detector has gone off in this area.
Alarm No. 106: Node 2: L01D06: Loop: 1 Device: 6
Display: NORMAL SMOKE(PHOTO) HVU E-6 SUPPLY DUCT V000 M 036
Location: Detector is located in the air handler in the C-Bldg dock at the far south end outside the laundry room Description: A Smoke Detector has gone off in this area.
11/18/2025 2
Alarm No. 107: Node 2: L01D07: Loop: 1 Device: 7
Display: NORMAL SMOKE (ION) S O-H DOOR AT CMPCTR V000 M 056
Location: Detector located at the overhead door near the trash compactor at the southend of C-1 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 108: Node 2: L01D08: Loop: 1 Device: 8
Display: NORMAL SMOKE (ION) CLEAN LINEN ROOM V000 M 045
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 109: Node 2: L01D09: Loop: 1 Device: 9
Display: NORMAL SMOKE (ION) DIRTY LINEN ROOM V000 M 039
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 110: Node 2: L01D10: Loop: 1 Device: 10
Display: NORMAL SMOKE (ION) LAUNDRY ROOM V000 M 039
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 111: Node 2: L01D11: Loop: 1 Device: 11
Display: NORMAL SMOKE (ION) DIRTY LINEN ROOM V000 M 033
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 112: Node 2: L01D12: Loop: 1 Device: 12
Display: NORMAL SMOKE (ION) SOUTH TV EQUIP. ROOM V000 M 039
Location: Detector located in the store room under the stairs coming down from the west plaza. It's on the dome side of the fence, get key from Dome security
11/18/2025 3
Description: A Smoke Detector has gone off in this area.
Alarm No. 113: Node 2: L01D13: Loop: 1 Device: 13
Display: NORMAL HEAT(ANALOG) LAUNDRY ROOM V000 M 060
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Heat Detector has gone off in this area.
Alarm No. 114: Node 2: L01D14: Loop: 1 Device: 14
Display: NORMAL SMOKE (ION) LAUNDRY ROOM V000 M 038
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 115: Node 2: L01D15: Loop: 1 Device: 15
Display: NORMAL HEAT(ANALOG) LAUNDRY ROOM V000 M 055
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Heat Detector has gone off in this area.
Alarm No. 116: Node 2: L01D16: Loop: 1 Device: 16
Display: NORMAL SMOKE (ION) LAUNDRY ROOM V000 M 045
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 117: Node 2: L01D17: Loop: 1 Device: 17
Display: NORMAL SMOKE (ION) LAUNDRY ROOM V000 M 034
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 118: Node 2: L01D18: Loop: 1 Device: 18
Display: NORMAL SMOKE (ION) PURCHASING RECEPTION V000 M 048
11/18/2025 4
Location: Detector located in the purchasing reception area on the sothend of C1 dock next to the laundry room Description: A Smoke Detector has gone off in this area.
Alarm No. 119: Node 2: L01D19: Loop: 1 Device: 19
Display: NORMAL HEAT(ANALOG) EMERGENCY GENERATOR V000 M 056
Location: Detector located in the C-Bldg emergency generator room on the southend of C1 dock Description: A Heat Detector has gone off in this area.
Alarm No. 120: Node 2: L01D20: Loop: 1 Device: 20
Display: NORMAL SMOKE (ION) EMERGENCY GENERATOR V000 M 069
Location: Detector located in the C-Bldg emergency generator room on the southend of C1 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 121: Node 2: L01D21: Loop: 1 Device: 21
Display: NORMAL HEAT(ANALOG) EMERGENCY GENERATOR V000 M 055
Location: Detector located in the C-Bldg emergency generator room on the southend of C1 dock Description: A Heat Detector has gone off in this area.
Alarm No. 122: Node 2: L01D22: Loop: 1 Device: 22
Display: NORMAL HEAT(ANALOG) SOUTHEAST DOCK AREA V000 M 044
Location: Detector located C1 dock air handler room directly across from purchasing Description: A Heat Detector has gone off in this area.
Alarm No. 123: Node 2: L01D23: Loop: 1 Device: 23
Display: NORMAL SMOKE (ION) SOUTHEAST DOCK AREA V000 M 050
Location: Detector located C1 dock air handler room directly across from purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 124: Node 2: L01D24: Loop: 1 Device: 24
Display: NORMAL SMOKE(PHOTO) AHU E-10 SUPPLY DUCT V000 M 038
11/18/2025 5
Building: C Location: Detector is located in the air handler in the mechanical room next to the emergency generator at the far south end of C dock Description: A Smoke Detector has gone off in this area.
Alarm No. 125: Node 2: L01D25: Loop: 1 Device: 25
Display: NORMAL HEAT(ANALOG) SOUTHEAST DOCK AREA V000 M 045
Location: Detector located C1 dock air handler room directly across from purchasing Description: A Heat Detector has gone off in this area.
Alarm No. 134: Node 2: L01D34: Loop: 1 Device: 34
Display: NORMAL HEAT(ANALOG) TRANSFER SWITCHGEAR V000 M 050
Location: Detector located in the transfer switch room C1 dock east wall across from NODE 2 Description: A Heat Detector has gone off in this area.
Alarm No. 135: Node 2: L01D35: Loop: 1 Device: 35
Display: NORMAL SMOKE (ION) TRANSFER SWITCHGEAR V000 M 068
Location: Detector located in the transfer switch room C1 dock east wall across from NODE 2 Description: A Smoke Detector has gone off in this area.
Alarm No. 136: Node 2: L01D36: Loop: 1 Device: 36
Display: NORMAL SMOKE (ION) SE MAIN SWITCHGEAR V000 M 046
Location: Detector located in the switchgear room C1 dock west wall next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 137: Node 2: L01D37: Loop: 1 Device: 37
Display: NORMAL HEAT(ANALOG) SE MAIN SWITCHGEAR V000 M 051
Location: Detector located in the switchgear room C1 dock west wall next to purchasing Description: A Heat Detector has gone off in this area.
Alarm No. 138: Node 2: L01D38: Loop: 1 Device: 38
11/18/2025 6
Display: NORMAL SMOKE (ION) PHONE ROOM LVL 1 SE V000 M 053
Location: Main phone room for C-Bldg is in back hallway behind room C-103 Description: A Smoke Detector has gone off in this area.
Alarm No. 139: Node 2: L01D39: Loop: 1 Device: 39
Display: NORMAL HEAT(ANALOG) NODE 2 - RISER RM 5 V000 M 049
Location: Detector located in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Heat Detector has gone off in this area.
Alarm No. 140: Node 2: L01D40: Loop: 1 Device: 40
Display: NORMAL SMOKE(PHOTO) AHU E-9 SUPPLY V000 M 038
Location: Detector located in the air handler in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Smoke Detector has gone off in this area.
Alarm No. 142: Node 2: L01D42: Loop: 1 Device: 42
Location: Detector located in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Heat Detector has gone off in this area.
Alarm No. 143: Node 2: L01D43: Loop: 1 Device: 43
Display: NORMAL HEAT(ANALOG) NODE 2 - RISER RM 5 V000 M 048
Location: Detector located in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Heat Detector has gone off in this area.
Alarm No. 144: Node 2: L01D44: Loop: 1 Device: 44
Display: NORMAL SMOKE(PHOTO) AHU E-2 SUPPLY DUCT V000 M 038
Location: Detector located in the air handler in NODE 2 room just north of the main switgear room on C1 dock west wall
11/18/2025 7
Alarm No. 145: Node 2: L01D45: Loop: 1 Device: 45
Location: Detector located in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Heat Detector has gone off in this area.
Alarm No. 146: Node 2: L01D46: Loop: 1 Device: 46
Display: NORMAL SMOKE (ION) LAUNDRY AREA V000 M 049
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 147: Node 2: L01D47: Loop: 1 Device: 47
Display: NORMAL SMOKE(PHOTO) BC E-3 SUPPLY DUCT V000 M 036
Location: Detector located in the air handler in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Smoke Detector has gone off in this area.
Alarm No. 148: Node 2: L01D48: Loop: 1 Device: 48
Location: Detector located in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Heat Detector has gone off in this area.
Alarm No. 149: Node 2: L01D49: Loop: 1 Device: 49
Location: Detector located in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Heat Detector has gone off in this area.
Alarm No. 150: Node 2: L01D50: Loop: 1 Device: 50
Display: NORMAL SMOKE(PHOTO) AHU E-1 SUPPLY DUCT V000 M 036
11/18/2025 8
Location: Detector located in the air handler in NODE 2 room just north of the main switgear room on C1 dock west wall Description: A Smoke Detector has gone off in this area.
Alarm No. 151: Node 2: L01D51: Loop: 1 Device: 51
Display: NORMAL SMOKE (ION) PURCHASING OFFICE V000 M 048
Location: Detector located in purchasing, Louis's office on the southend of C1 dock next to the laundry room Description: A Smoke Detector has gone off in this area.
Alarm No. 152: Node 2: L01D52: Loop: 1 Device: 52
Display: NORMAL SMOKE (ION) LAUNDRY BREAK ROOM V000 M 045
Location: Detector located in the laundry room breakroom on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 153: Node 2: L01D53: Loop: 1 Device: 53
Display: NORMAL SMOKE (ION) FIELD OF DREAMS PUMP V000 M 065
Location: Detector located in the field of dreams pump room on the east side of the gold parking deck bottom level Description: A Smoke Detector has gone off in this area.
Alarm No. 154: Node 2: L01D54: Loop: 1 Device: 54
Display: NORMAL HEAT(ANALOG) O-H DOOR AT COMPACTR V000 M 051
Location: Detector located in the storage room next to the trash compactor at the southend of C-1 dock at overhead door Description: A Heat Detector has gone off in this area.
Alarm No. 155: Node 2: L01D55: Loop: 1 Device: 55
Display: NORMAL HEAT(ANALOG) LAUNDRY ROOM V000 M 051
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Heat Detector has gone off in this area.
11/18/2025 9
Alarm No. 156: Node 2: L01D56: Loop: 1 Device: 56
Display: NORMAL SMOKE (ION) LAUNDRY ROOM V000 M 045
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 157: Node 2: L01D57: Loop: 1 Device: 57
Display: NORMAL SMOKE (ION) LAUNDRY ROOM V000 M 044
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 158: Node 2: L01D58: Loop: 1 Device: 58
Display: NORMAL HEAT(ANALOG) LAUNDRY ROOM V000 M 050
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Heat Detector has gone off in this area.
Alarm No. 159: Node 2: L01D59: Loop: 1 Device: 59
Display: NORMAL SMOKE (ION) LAUNDRY ROOM V000 M 046
Location: Detector located in the laundry room on the southend of C1 dock next to purchasing Description: A Smoke Detector has gone off in this area.
Alarm No. 162: Node 2: L01D62: Loop: 1 Device: 62
Display: NORMAL SMOKE (ION) PURCHASING LEVEL 1 V000 M 061
Location: Detector located in purchasing far southwest corner of the warehouse inside the room with the rollup door on the southend of C1 dock next to the laundry
11/18/2025 10
11/18/2025 11
Alarm No. 209: Node 2: L02D09: Loop: 2 Device: 9
Display: NORMAL SMOKE(PHOTO) AHU P-8 SUPPLY DUCT V000 M 038
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 210: Node 2: L02D10: Loop: 2 Device: 10
Display: NORMAL SMOKE(PHOTO) AHU P-8 RETURN DUCT V000 M 038
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 214: Node 2: L02D14: Loop: 2 Device: 14
Display: NORMAL SMOKE (ION) MTG ROOMS L1 WMNS RR V000 M 042
Location: This detector is located in the housekeeping store room located in the womens restroom across from room C110 Description: A Smoke Detector has gone off in this area.
Alarm No. 215: Node 2: L02D15: Loop: 2 Device: 15
Display: NORMAL SMOKE (ION) C-1 S WOMENS RESTRM V000 M 063
Location: This detector is located in the housekeeping store room located in the womens restroom on the south wall of C1 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 216: Node 2: L02D16: Loop: 2 Device: 16
Display: NORMAL SMOKE (ION) C-1 S MENS RESTROOM V000 M 066
Location: This detector is located in the housekeeping store room located in the mens restroom on the south wall of C1 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 217: Node 2: L02D17: Loop: 2 Device: 17
11/18/2025 12
Display: NORMAL SMOKE (ION) MTG ROOMS L1 MENS RR V000 M 045
Location: This detector is located in the housekeeping store room located in the mens restroom across from room C107 Description: A Smoke Detector has gone off in this area.
Alarm No. 224: Node 2: L02D24: Loop: 2 Device: 24
Display: NORMAL SMOKE (ION) BLDG C SW PHONE ROOM V000 M 043
Location: Main phone room for C-Bldg is in back hallway behind room C-103 Description: A Smoke Detector has gone off in this area.
Alarm No. 225: Node 2: L02D25: Loop: 2 Device: 25
Display: NORMAL SMOKE (ION) BLDG C SW PHONE ROOM V000 M 049
Location: Main phone room for C-Bldg is in back hallway behind room C-103 Description: A Smoke Detector has gone off in this area.
Alarm No. 226: Node 2: L02D26: Loop: 2 Device: 26
Display: NORMAL HEAT(ANALOG) LEVEL 1 SOUTHWEST V000 M 048
Location: This detector is located in the in the mecanical room in the back hallway near auditorium 101 in C- Bldg Description: A Heat Detector has gone off in this area.
Alarm No. 227: Node 2: L02D27: Loop: 2 Device: 27
Display: NORMAL SMOKE(PHOTO) AHU E-3 SUPPLY DUCT V000 M 039
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 228: Node 2: L02D28: Loop: 2 Device: 28
Display: NORMAL SMOKE (ION) LEVEL 1 NEAR MR C103 V000 M 045
11/18/2025 13
Location: This detector is located in the small CCLD storage room in the back hallway next to C103 on left heading into the concourse Description: A Smoke Detector has gone off in this area.
Alarm No. 229: Node 2: L02D29: Loop: 2 Device: 29
Display: NORMAL SMOKE (ION) LEVEL 1 NEAR C103 V000 M 054
Location: This detector is located in the cappochino coffee storage room in the back hallway next to C103 on left heading into the concourse Description: A Smoke Detector has gone off in this area.
Alarm No. 230: Node 2: L02D30: Loop: 2 Device: 30
Display: NORMAL SMOKE(PHOTO) AHU E-4 SUPPLY DUCT V000 M 039
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 231: Node 2: L02D31: Loop: 2 Device: 31
Location: This detector is located in the in the mecanical room in the back hallway near auditorium 101 in C- Bldg Description: A Heat Detector has gone off in this area.
Alarm No. 232: Node 2: L02D32: Loop: 2 Device: 32
Location: This detector is located in the in the mecanical room in the back hallway near auditorium 101 in C- Bldg Description: A Heat Detector has gone off in this area.
Alarm No. 233: Node 2: L02D33: Loop: 2 Device: 33
Display: NORMAL SMOKE(PHOTO) AHU B-10 SUPPLY DUCT V000 M 039
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg
11/18/2025 14
Description: A Smoke Detector has gone off in this area.
Alarm No. 234: Node 2: L02D34: Loop: 2 Device: 34
Display: NORMAL SMOKE (ION) ELEV 16-17 LVL 1 V000 M 036
Location: This detector is located outside elevator s 16 and 17 level 1 near C101 Description: A Smoke Detector has gone off in this area.
Alarm No. 235: Node 2: L02D35: Loop: 2 Device: 35
Display: NORMAL SMOKE (ION) LVL 1 SW HOT WATER V000 M 039
Location: This detector is located in the housekeeping store room across from the batrooms near C101 Description: A Smoke Detector has gone off in this area.
Alarm No. 236: Node 2: L02D36: Loop: 2 Device: 36
Display: NORMAL HEAT(ANALOG) LEVEL 1 SOUTHWEST V000 M 046
Location: Detector is located in the air handler room in the far southwest corner of C-Bldg level 1 next to the telephone switch room Description: A Heat Detector has gone off in this area.
Alarm No. 239: Node 2: L02D39: Loop: 2 Device: 39
Location: Detector is located in the air handler room in the far southwest corner of C-Bldg level 1 next to the telephone switch room Description: A Heat Detector has gone off in this area.
Alarm No. 240: Node 2: L02D40: Loop: 2 Device: 40
Display: NORMAL SMOKE(PHOTO) AHU E-5 SUPPLY DUCT V000 M 037
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 241: Node 2: L02D41: Loop: 2 Device: 41
11/18/2025 15
Location: Detector is located in the air handler room in the far southwest corner of C-Bldg level 1 next to the telephone switch room Description: A Heat Detector has gone off in this area.
Alarm No. 242: Node 2: L02D42: Loop: 2 Device: 42
Display: NORMAL SMOKE(PHOTO) AHU E-6 SUPPLY DUCT V000 M 038
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 243: Node 2: L02D43: Loop: 2 Device: 43
Display: NORMAL SMOKE (ION) LVL 1 AUDITORIUM V000 M 039
Location: This detector is located over the ramp that leads to the stage on the eastside of the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 245: Node 2: L02D45: Loop: 2 Device: 45
Display: NORMAL SMOKE (ION) LVL 1 AUDITORIUM V000 M 043
Location: This detector is located over the ramp that leads to the stage on the eastside of the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 246: Node 2: L02D46: Loop: 2 Device: 46
Display: NORMAL SMOKE (ION) LVL 1 AUDITORIUM V000 M 048
Location: This detector is located over the ramp that leads to the stage on the eastside of the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 247: Node 2: L02D47: Loop: 2 Device: 47
Display: NORMAL SMOKE (ION) C101 STAGE EAST V000 M 039
Location: This detector is located on the stage in the C101 auditorium
11/18/2025 16
Alarm No. 248: Node 2: L02D48: Loop: 2 Device: 48
Display: NORMAL SMOKE (ION) C101 STAGE WEST V000 M 044
Location: This detector is located on the stage in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 249: Node 2: L02D49: Loop: 2 Device: 49
Display: NORMAL SMOKE (ION) C101 BACKSTAGE V000 M 045
Location: This detector is located behind the stage in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 250: Node 2: L02D50: Loop: 2 Device: 50
Display: NORMAL SMOKE (ION) C101 BACKSTAGE V000 M 039
Location: This detector is located behind the stage in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 251: Node 2: L02D51: Loop: 2 Device: 51
Display: NORMAL SMOKE (ION) C101 SEATING AREA V000 M 043
Location: This detector is located over the seating area in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 252: Node 2: L02D52: Loop: 2 Device: 52
Display: NORMAL SMOKE (ION) C101 SEATING AREA V000 M 042
Location: This detector is located over the seating area in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 253: Node 2: L02D53: Loop: 2 Device: 53
Display: NORMAL SMOKE (ION) C101 SEATING AREA V000 M 037
Location: This detector is located over the seating area in the C101 auditorium
11/18/2025 17
Description: A Smoke Detector has gone off in this area.
Alarm No. 254: Node 2: L02D54: Loop: 2 Device: 54
Display: NORMAL SMOKE (ION) C101 WEST ENTRANCE V000 M 049
Location: This detector is located in the entrance lobby on the westside of the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 255: Node 2: L02D55: Loop: 2 Device: 55
Display: NORMAL SMOKE (ION) C101 SEATING AREA V000 M 039
Location: This detector is located over the seating area in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 256: Node 2: L02D56: Loop: 2 Device: 56
Display: NORMAL SMOKE (ION) C101 SEATING AREA V000 M 045
Location: This detector is located over the seating area in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 257: Node 2: L02D57: Loop: 2 Device: 57
Display: NORMAL SMOKE (ION) C101 SEATING AREA V000 M 044
Location: This detector is located over the seating area in the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 258: Node 2: L02D58: Loop: 2 Device: 58
Display: NORMAL SMOKE (ION) C101 EAST ENTRANCE V000 M 050
Location: This detector is located in the entrance lobby on the eastside of the C101 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 259: Node 2: L02D59: Loop: 2 Device: 59
Display: NORMAL SMOKE (ION) LVL 1 LECTURE A-V RM V000 M 046
11/18/2025 18
Location: This detector is located in the projection booth in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 260: Node 2: L02D60: Loop: 2 Device: 60
Display: NORMAL SMOKE (ION) C102 SEATING AREA V000 M 045
Location: This detector is located over the seating area in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 261: Node 2: L02D61: Loop: 2 Device: 61
Display: NORMAL SMOKE (ION) LVL 1 LECTURE HALL V000 M 043
Location: This detector is located over the ramp on the west side in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 262: Node 2: L02D62: Loop: 2 Device: 62
Display: NORMAL SMOKE (ION) C102 SEATING AREA V000 M 045
Location: This detector is located over the seating area in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 263: Node 2: L02D63: Loop: 2 Device: 63
Display: NORMAL SMOKE (ION) C102 AV ROOM V000 M 043
Location: This detector is located in the AV store room in the southeast corner of the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 264: Node 2: L02D64: Loop: 2 Device: 64
Display: NORMAL SMOKE (ION) C102 SEATING AREA V000 M 043
Location: This detector is located over the stage in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 265: Node 2: L02D65: Loop: 2 Device: 65
Display: NORMAL SMOKE (ION) C102 SEATING AREA V000 M 038
11/18/2025 19
Building: C Location: This detector is located over the stage in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 266: Node 2: L02D66: Loop: 2 Device: 66
Display: NORMAL SMOKE (ION) WC RETAIL SHOP V000 M 056
Location: This detector is located in the Kinkos in the C-Bldg main entrance Description: A Smoke Detector has gone off in this area.
Alarm No. 267: Node 2: L02D67: Loop: 2 Device: 67
Display: NORMAL SMOKE (ION) WC COAT CHECK ROOM V000 M 060
Location: This detector is located in the coat chek room in the C-Bldg main entrance Description: A Smoke Detector has gone off in this area.
Alarm No. 268: Node 2: L02D68: Loop: 2 Device: 68
Display: NORMAL SMOKE (ION) LVL 2 COAT CHECK V000 M 050
Location: This detector is located in the coat chek room on level 2 to the right of elevators 16 and 17 if you're facing the elevators Description: A Smoke Detector has gone off in this area.
Alarm No. 269: Node 2: L02D69: Loop: 2 Device: 69
Display: NORMAL SMOKE (ION) ELEV 16-17 L2 LOBBY V000 M 039
Location: This detector is located in front of elevators 16 and 17 on level 2 C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 270: Node 2: L02D70: Loop: 2 Device: 70
Display: NORMAL SMOKE (ION) C102 SEATING AREA V000 M 048
Location: This detector is located over the seating area in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 271: Node 2: L02D71: Loop: 2 Device: 71
11/18/2025 20
Display: NORMAL SMOKE(PHOTO) AHU B-10 RETURN DUCT V000 M 039
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 272: Node 2: L02D72: Loop: 2 Device: 72
Display: NORMAL SMOKE(PHOTO) AHU E-3 RETURN DUCT V000 M 038
Location: This detector is located in the air handler, located in the mecanical room in the back hallway near auditorium 101 in C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 273: Node 2: L02D73: Loop: 2 Device: 73
Display: NORMAL SMOKE (ION) LVL 1 MEETING ROOM S V000 M 043
Location: This detector is located in the service hallway next to room C103 heading out into the concourse Description: A Smoke Detector has gone off in this area.
Alarm No. 274: Node 2: L02D74: Loop: 2 Device: 74
Location: This detector is located in the service hallway in front of the CCLD main frame room for C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 275: Node 2: L02D75: Loop: 2 Device: 75
Display: NORMAL SMOKE (ION) LVL 1 MEETING ROOM S V000 M 038
Location: This detector is located in the service hallway behind room C103 Description: A Smoke Detector has gone off in this area.
Alarm No. 276: Node 2: L02D76: Loop: 2 Device: 76
Display: NORMAL SMOKE (ION) LVL 1 MEETING ROOM S V000 M 038
Location: This detector is located in the service hallway behind room C104
11/18/2025 21
Alarm No. 277: Node 2: L02D77: Loop: 2 Device: 77
Display: NORMAL SMOKE (ION) LVL 1 MEETING ROOM S V000 M 033
Location: This detector is located in the service hallway behind room C105 Description: A Smoke Detector has gone off in this area.
Alarm No. 278: Node 2: L02D78: Loop: 2 Device: 78
Display: NORMAL SMOKE (ION) C105-C106 PARTITION V000 M 050
Location: This detector is located in the air wall pocket for C105/106 rooms Description: A Smoke Detector has gone off in this area.
Alarm No. 279: Node 2: L02D79: Loop: 2 Device: 79
Display: NORMAL SMOKE (ION) LVL 1 MEETING ROOM S V000 M 040
Location: This detector is located in the service hallway behind room C106 Description: A Smoke Detector has gone off in this area.
Alarm No. 280: Node 2: L02D80: Loop: 2 Device: 80
Display: NORMAL SMOKE (ION) LVL 1 LECTURE HALL V000 M 045
Location: This detector is located over the seating area in the C102 auditorium Description: A Smoke Detector has gone off in this area.
Alarm No. 281: Node 2: L02D81: Loop: 2 Device: 81
Display: NORMAL SMOKE (ION) BLDG C SW PHONE ROOM V000 M 051
Location: Main phone room for C-Bldg is in back hallway behind room C-103 Description: A Smoke Detector has gone off in this area.
Alarm No. 287: Node 2: L02D87: Loop: 2 Device: 87
Display: NORMAL SMOKE (ION) LVL 1 AUDITORIUM RR V000 M 036
Location: This detector is located in the hallway near the restrooms near the C101 auditorium
11/18/2025 22
Description: A Smoke Detector has gone off in this area.
Alarm No. 288: Node 2: L02D88: Loop: 2 Device: 88
Display: NORMAL SMOKE (ION) LVL 1 SW BY ELEV 17 V000 M 039
Location: This detector is located in the housekeeping store room next to elevators 16 and 17 Description: A Smoke Detector has gone off in this area.
Alarm No. 289: Node 2: L02D89: Loop: 2 Device: 89
Display: NORMAL SMOKE (ION) LVL 1 SW BY ELEV 17 V000 M 043
Location: This detector is located in the hallway between the 2 housekeeping store rooms next to elevators 16 and 17 Description: A Smoke Detector has gone off in this area.
Alarm No. 290: Node 2: L02D90: Loop: 2 Device: 90
Display: NORMAL SMOKE (ION) LVL 1 SW BY ELEV 17 V000 M 039
Location: This detector is located in the housekeeping store room across the hall from the housekeeping store room next to elevators 16 and 17 Description: A Smoke Detector has gone off in this area.
Alarm No. 293: Node 2: L02D93: Loop: 2 Device: 93
Display: NORMAL SMOKE (ION) C-1 S EGRESS O-H DR V000 M 050
Location: This detector is located in front of the overhead door inside the lobby in the southeast corner of C1hall in front of the round elevator 21 Description: A Smoke Detector has gone off in this area.
Alarm No. 298: Node 2: L02D98: Loop: 2 Device: 98
Display: NORMAL HEAT(ANALOG) ELEV 16-17 PIT HEAT V000 M 046
Location: This detector is located in the pit of elevators 16 and 17 Description: A Heat Detector has gone off in this area.
11/18/2025 23
Alarm No. 301: Node 2: L03D01: Loop: 3 Device: 1
Display: NORMAL SMOKE(PHOTO) HVU E-5 SUPPLY DUCT V000 M 039
Location: This detector is loocated in the air handler located on the ceiling on the nrthend of C1 dock in front of the large freight elevator Description: A Smoke Detector has gone off in this area.
Alarm No. 302: Node 2: L03D02: Loop: 3 Device: 2
Display: NORMAL SMOKE(PHOTO) HVU E-5 RETURN DUCT V000 M 038
Location: This detector is loocated in the air handler located on the ceiling on the nrthend of C1 dock in front of the large freight elevator Description: A Smoke Detector has gone off in this area.
Alarm No. 303: Node 2: L03D03: Loop: 3 Device: 3
Display: NORMAL SMOKE (ION) ELEV 25 LVL 1 LOBBY V000 M 046
Location: This detector is located outside the #25 freight elevator on level 1 on C dock Description: A Smoke Detector has gone off in this area.
Alarm No. 304: Node 2: L03D04: Loop: 3 Device: 4
Display: NORMAL SMOKE (ION) C-1 DOCK LEVEL 1 V000 M 054
Location: This detector located in the electrical maintenance shop on C1 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 305: Node 2: L03D05: Loop: 3 Device: 5
Display: NORMAL SMOKE (ION) SE SERVICE AREA LVL1 V000 M 065
Location: This detector is located between the electrical mainenance shop and Node 2 in the dock area level 1 Description: A Smoke Detector has gone off in this area.
Alarm No. 306: Node 2: L03D06: Loop: 3 Device: 6
Display: NORMAL HEAT(ANALOG) S SERVICE AREA LVL 1 V000 M 051
11/18/2025 24
Location: This detector is located between the electrical mainenance shop and Node 2 in the dock area level 1 Description: A Heat Detector has gone off in this area.
Alarm No. 307: Node 2: L03D07: Loop: 3 Device: 7
Display: NORMAL SMOKE (ION) ENGINEERING LVL 1 V000 M 050
Location: This detector located in the electrical maintenance shop on C1 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 308: Node 2: L03D08: Loop: 3 Device: 8
Display: NORMAL HEAT(ANALOG) ENGINEERING SHOP V000 M 050
Location: Detector is located in the C1 engineering shop Description: A Heat Detector has gone off in this area.
Alarm No. 309: Node 2: L03D09: Loop: 3 Device: 9
Display: NORMAL HEAT(ANALOG) ENGINEERING SHOP V000 M 050
Location: Detector is located in the C1 engineering shop Description: A Heat Detector has gone off in this area.
Alarm No. 310: Node 2: L03D10: Loop: 3 Device: 10
Display: NORMAL SMOKE (ION) ELEV 24 LVL 1 LOBBY V000 M 042
Location: This detector is located outside the #24 elevator on level 1 on C dock Description: A Smoke Detector has gone off in this area.
Alarm No. 311: Node 2: L03D11: Loop: 3 Device: 11
Display: NORMAL SMOKE (ION) LEVEL 1 TRUCK DOCK V000 M 046
Location: This detector is located in the store room next to the #24 elevator on level 1 on C dock Description: A Smoke Detector has gone off in this area.
Alarm No. 312: Node 2: L03D12: Loop: 3 Device: 12
Display: NORMAL SMOKE(PHOTO) HVU E-7 SUPPLY DUCT V000 M 038
11/18/2025 25
Building: C Location: This detector is located in the air handler located in the ceiling of the hallway behind the C1 Papa Johns Description: A Smoke Detector has gone off in this area.
Alarm No. 313: Node 2: L03D13: Loop: 3 Device: 13
Display: NORMAL SMOKE (ION) C-1 E WOMENS ROOM V000 M 054
Location: This detector is located in the housekeeping store room in the ladies room on the east wall of C1 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 315: Node 2: L03D15: Loop: 3 Device: 15
Display: NORMAL SMOKE (ION) C-1 E PIZZA SERVE V000 M 061
Location: This detector is located in the prep area of the C1 Papa Johns Description: A Smoke Detector has gone off in this area.
Alarm No. 317: Node 2: L03D17: Loop: 3 Device: 17
Display: NORMAL SMOKE (ION) C-1 PARTITION WALL V000 M 039
Location: This detector is located in theC1 air wall pocket Description: A Smoke Detector has gone off in this area.
Alarm No. 318: Node 2: L03D18: Loop: 3 Device: 18
Display: NORMAL SMOKE(PHOTO) C-1 E CONCESSIONS V000 M 053
Location: This detector is located in the C1 concessions stand Description: A Smoke Detector has gone off in this area.
Alarm No. 319: Node 2: L03D19: Loop: 3 Device: 19
Display: NORMAL SMOKE (ION) C-1 E CONCESSIONS V000 M 038
Location: This detector is located in the C1 concessions stand Description: A Smoke Detector has gone off in this area.
Alarm No. 320: Node 2: L03D20: Loop: 3 Device: 20
11/18/2025 26
Display: NORMAL SMOKE (ION) C-1 E CONCESSION V000 M 059
Location: This detector is located in the C1 concessions stand Description: A Smoke Detector has gone off in this area.
Alarm No. 321: Node 2: L03D21: Loop: 3 Device: 21
Display: NORMAL SMOKE (ION) C-1 PIZZA FREEZER V000 M 061
Location: This detector is located above the freezer in the Levy store room across from the C1 engineering shop Description: A Smoke Detector has gone off in this area.
Alarm No. 322: Node 2: L03D22: Loop: 3 Device: 22
Display: NORMAL SMOKE (ION) C-1 COFFEE SERVICE V000 M 056
Location: This detector is located in the Levy store room that is across the hallway, behind the C1 Papa Johns Description: A Smoke Detector has gone off in this area.
Alarm No. 323: Node 2: L03D23: Loop: 3 Device: 23
Display: NORMAL SMOKE (ION) C-1 COFFEE SERVICE V000 M 054
Location: This detector is located in the Levy store room that is across the hallway, behind the C1 Papa Johns Description: A Smoke Detector has gone off in this area.
Alarm No. 324: Node 2: L03D24: Loop: 3 Device: 24
Display: NORMAL SMOKE (ION) C-1 COFFEE SERVICE V000 M 043
Location: This detector is located in the Levy store room that is across the hallway, behind the C1 Papa Johns in the mop sink closet Description: A Smoke Detector has gone off in this area.
Alarm No. 325: Node 2: L03D25: Loop: 3 Device: 25
Display: NORMAL SMOKE (ION) C-1 SHOW SECURITY V000 M 061
Location: This detector is located in the security office at the northend of C1 dock
11/18/2025 27
Alarm No. 326: Node 2: L03D26: Loop: 3 Device: 26
Display: NORMAL SMOKE(PHOTO) HVU E-4 SUPPLY DUCT V000 M 037
Location: This detector is located in the air handler in the ceiling at the northend of C1 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 327: Node 2: L03D27: Loop: 3 Device: 27
Display: NORMAL SMOKE (ION) CHILLER ROOM LEVEL 1 V000 M 051
Location: This detector is located in the phase 4 chiller room on C2 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 328: Node 2: L03D28: Loop: 3 Device: 28
Display: NORMAL SMOKE (ION) CHILLER ROOM LEVEL 1 V000 M 057
Location: This detector is located in the phase 4 chiller room on C2 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 329: Node 2: L03D29: Loop: 3 Device: 29
Display: NORMAL SMOKE (ION) C-2 EAST CONCESSIONS V000 M 045
Location: This detector is located in the C2 concessions stand Description: A Smoke Detector has gone off in this area.
Alarm No. 330: Node 2: L03D30: Loop: 3 Device: 30
Display: NORMAL SMOKE (ION) C-2 EAST CONCESSIONS V000 M 036
Location: This detector is located in the C2 concessions stand Description: A Smoke Detector has gone off in this area.
Alarm No. 331: Node 2: L03D31: Loop: 3 Device: 31
Display: NORMAL SMOKE (ION) C-2 EAST CONCESSION V000 M 059
Location: This detector is located in the C2 concessions stand
11/18/2025 28
Alarm No. 332: Node 2: L03D32: Loop: 3 Device: 32
Display: NORMAL SMOKE(PHOTO) C-2 DOCK SECURITY RM V000 M 050
Location: This detector is located in the show security office at the C1/2 point dockside next to the housekeeping store room Description: A Smoke Detector has gone off in this area.
Alarm No. 333: Node 2: L03D33: Loop: 3 Device: 33
Display: NORMAL SMOKE (ION) CHILLER ROOM LEVEL 1 V000 M 057
Location: This detector is located in the phase 4 chiller room on C2 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 342: Node 2: L03D42: Loop: 3 Device: 42
Display: NORMAL SMOKE(PHOTO) AHU E-7 SUPPLY DUCT V000 M 039
Location: This detector is located in the air handler in the ceiling of the phase 4 chiller room on C2 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 343: Node 2: L03D43: Loop: 3 Device: 43
Display: NORMAL SMOKE (ION) C-2 E WOMENS RESTRM V000 M 044
Location: This detector is located in the housekeeping store room in the womens restroom on the east wall of C2 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 344: Node 2: L03D44: Loop: 3 Device: 44
Display: NORMAL SMOKE (ION) C-2 PARTITION WALL V000 M 050
Location: This detector is located in the C2 air wall pocket Description: A Smoke Detector has gone off in this area.
Alarm No. 346: Node 2: L03D46: Loop: 3 Device: 46
Display: NORMAL HEAT(ANALOG) ELEV 25 PIT HEAT V000 M 050
11/18/2025 29
Building: C Location: This detector is located in the pit of elevator 25 located on the C1 dock Description: A Heat Detector has gone off in this area.
Alarm No. 348: Node 2: L03D48: Loop: 3 Device: 48
Display: NORMAL HEAT(ANALOG) ELEV 24 PIT HEAT V000 M 049
Location: This detector is located in the pit of elevator 24 located on the C1 dock Description: A Heat Detector has gone off in this area.
Alarm No. 350: Node 2: L03D50: Loop: 3 Device: 50
Display: NORMAL SMOKE (ION) C-1 EAST EGRESS CNTR V000 M 069
Location: This detector is located in the hallway just outside the C1 engieering shop across from the Levy store room Description: A Smoke Detector has gone off in this area.
Alarm No. 351: Node 2: L03D51: Loop: 3 Device: 51
Display: NORMAL SMOKE (ION) COFFEE SERVICE DRY V000 M 059
Location: This detector is located in the storage closet inside the Levy strore room behind the C1 Papa Johns Description: A Smoke Detector has gone off in this area.
Alarm No. 352: Node 2: L03D52: Loop: 3 Device: 52
Display: NORMAL SMOKE (ION) C-2 DOCK O-H DOOR V000 M 045
Location: This detector is located at the southend of C2 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 353: Node 2: L03D53: Loop: 3 Device: 53
Display: NORMAL SMOKE (ION) C-2 DOCK AREA V000 M 062
Location: This detector is located in the housekeeping store room at the C1/2 point lobby dockside Description: A Smoke Detector has gone off in this area.
Alarm No. 354: Node 2: L03D54: Loop: 3 Device: 54
11/18/2025 30
Display: NORMAL SMOKE (ION) C-1 SE SOFFIT AT O-H V001 M 061
Location: This detector is located in C1 hall at the overhead far southeast corner Description: A Smoke Detector has gone off in this area.
Alarm No. 355: Node 2: L03D55: Loop: 3 Device: 55
Display: NORMAL SMOKE (ION) C-1 CEN O-H DOOR E V000 M 059
Location: This detector is located in C1 hall at the overhead door leading to the C1 engineering shop Description: A Smoke Detector has gone off in this area.
Alarm No. 356: Node 2: L03D56: Loop: 3 Device: 56
Display: NORMAL SMOKE (ION) C-1 CEN O-H DOOR E V000 M 068
Location: This detector is located in the hallway outside the C1 engineering shop at the overhead door leading into C1 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 357: Node 2: L03D57: Loop: 3 Device: 57
Display: NORMAL SMOKE (ION) C-1 NE AT O-H DOOR V000 M 054
Location: This detector is located in C1 hall at the overhead at the C1/2 point dockside Description: A Smoke Detector has gone off in this area.
Alarm No. 359: Node 2: L03D59: Loop: 3 Device: 59
Display: NORMAL HEAT(ANALOG) ELEV 21 PIT DETECTOR V000 M 048
Location: This detector is located in the pit of elevator 21 located in the lobby of the southwest corner of C B-ldg next to the escalators Description: A Heat Detector has gone off in this area.
Alarm No. 361: Node 2: L03D61: Loop: 3 Device: 61
Display: NORMAL SMOKE (ION) ELEV 21 EQUIPMENT RM V000 M 043
Location: This detector is located in machine room for elevator 21 and is located directly behind the elevator accessed through the service tunnel on level 1 southwest corner
11/18/2025 31
Description: A Smoke Detector has gone off in this area.
Alarm No. 362: Node 2: L03D62: Loop: 3 Device: 62
Display: NORMAL SMOKE (ION) ELEV 21 LVL 1 LOBBY V000 M 031
Location: This detector is located outside the elevator 21 on level 1 located at the bottom of the escalators in the lobby southwest corner of C-Bldg Description: A Smoke Detector has gone off in this area.
Alarm No. 363: Node 2: L03D63: Loop: 3 Device: 63
Display: NORMAL SMOKE (ION) S EGRESS TO PARKING V000 M 054
Location: This detector is located in the hall south of elevator 21 just before going through the overhead door into the back service hallway Description: A Smoke Detector has gone off in this area.
Alarm No. 364: Node 2: L03D64: Loop: 3 Device: 64
Display: NORMAL SMOKE (ION) S EGRESS TO PARKING V000 M 054
Location: This detector is located in the back service hallway at the overhead door heading into the gold parking deck Description: A Smoke Detector has gone off in this area.
Alarm No. 365: Node 2: L03D65: Loop: 3 Device: 65
Display: NORMAL SMOKE (ION) LVL 1 S MEETING ROOM V000 M 038
Location: This detector is located in the service hallway behind room C110 Description: A Smoke Detector has gone off in this area.
Alarm No. 366: Node 2: L03D66: Loop: 3 Device: 66
Display: NORMAL SMOKE (ION) LVL 1 S MEETING ROOM V000 M 045
Location: This detector is located in the service hallway behind room C109 Description: A Smoke Detector has gone off in this area.
Alarm No. 367: Node 2: L03D67: Loop: 3 Device: 67
11/18/2025 32
Display: NORMAL SMOKE (ION) LVL 1 S MEETING ROOM V000 M 036
Location: This detector is located in the service hallway behind room C108 Description: A Smoke Detector has gone off in this area.
Alarm No. 368: Node 2: L03D68: Loop: 3 Device: 68
Display: NORMAL SMOKE (ION) C108-C109 PARTITION V000 M 039
Location: This detector is located in the air wall stoage in room C108 Description: A Smoke Detector has gone off in this area.
Alarm No. 369: Node 2: L03D69: Loop: 3 Device: 69
Location: This detector is located in the service hallway behind room C108 Description: A Smoke Detector has gone off in this area.
Alarm No. 370: Node 2: L03D70: Loop: 3 Device: 70
Display: NORMAL SMOKE (ION) LVL 1 SETUP STORAGE V000 M 038
Location: This detector is located in the setup store room in service hallway behind room C107 Description: A Smoke Detector has gone off in this area.
Alarm No. 371: Node 2: L03D71: Loop: 3 Device: 71
Display: NORMAL SMOKE (ION) LVL 1 SETUP STORAGE V000 M 034
Location: This detector is located in the setup store room in service hallway behind room C107 Description: A Smoke Detector has gone off in this area.
Alarm No. 372: Node 2: L03D72: Loop: 3 Device: 72
Display: NORMAL SMOKE (ION) LVL 1 MEETING ROOM S V000 M 054
Location: This detector is located in the service hallway behind room C107
11/18/2025 33
Alarm No. 375: Node 2: L03D75: Loop: 3 Device: 75
Display: NORMAL SMOKE(PHOTO) HVU E-3 SUPPLY DUCT V000 M 039
Location: This detector is located in the air handler in the ceiling at the northend of C2 dock
11/18/2025 34
11/18/2025 35
Alarm No. 401: Node 2: L04D01: Loop: 4 Device: 1
Display: NORMAL SMOKE (ION) ELEV 22 MACHINE ROOM V000 M 037
Location: This detector is located in machine room for elevator 22 located on the C dock at the C2/3 point next to the vending machines Description: A Smoke Detector has gone off in this area.
Alarm No. 403: Node 2: L04D03: Loop: 4 Device: 3
Display: NORMAL SMOKE (ION) ELEV 22 LOBBY LVL 1 V000 M 054
Location: This detector is located outside the elevator 22 located on the C-Bldg side of the B/C connector at the C2/3 point eastside of the hall Description: A Smoke Detector has gone off in this area.
Alarm No. 404: Node 2: L04D04: Loop: 4 Device: 4
Display: NORMAL HEAT(ANALOG) ELEV 22 PIT V000 M 046
Location: This detector is located in the pit of elevator 22 located on the C-Bldg side of the B/C connector at the C2/3 point eastside of the hall Description: A Heat Detector has gone off in this area.
Alarm No. 407: Node 2: L04D07: Loop: 4 Device: 7
Display: NORMAL SMOKE (ION) ELEV 23 EQUIPMENT RM V000 M 065
Location: This detector is located in machine room for elevator 23 located on the B-Bldg side of the B/C connector at the B3/4 point westside of the hall Description: A Smoke Detector has gone off in this area.
Alarm No. 408: Node 2: L04D08: Loop: 4 Device: 8
Display: NORMAL SMOKE (ION) C-3 RISER ROOM 2 V000 M 043
Location: This detector is located in the C3 riser room 2 located at the far northend of C3 dock, also is the fire protection office Description: A Smoke Detector has gone off in this area.
Alarm No. 409: Node 2: L04D09: Loop: 4 Device: 9
11/18/2025 36
Display: NORMAL SMOKE (ION) C-3 E WOMENS RESTRM V000 M 051
Location: This detector is located in the housekeeping storage room in the womens restroom on the east wall of C3 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 410: Node 2: L04D10: Loop: 4 Device: 10
Display: NORMAL SMOKE(PHOTO) HVU E-2 SUPPLY DUCT V000 M 039
Location: This detector is located inside the air handler in the ceiling at the far northend of C3 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 411: Node 2: L04D11: Loop: 4 Device: 11
Display: NORMAL SMOKE (ION) C-3 EAST CONCESSIONS V000 M 055
Location: This detector is located in the C3 hall concessions stand on the east wall Description: A Smoke Detector has gone off in this area.
Alarm No. 412: Node 2: L04D12: Loop: 4 Device: 12
Display: NORMAL SMOKE (ION) C-3 EAST CONCESSIONS V000 M 039
Location: This detector is located in the C3 hall concessions stand on the east wall Description: A Smoke Detector has gone off in this area.
Alarm No. 413: Node 2: L04D13: Loop: 4 Device: 13
Display: NORMAL SMOKE (ION) C-3 EAST CONCESSIONS V000 M 033
Location: This detector is located in the C3 hall concessions stand on the east wall Description: A Smoke Detector has gone off in this area.
Alarm No. 414: Node 2: L04D14: Loop: 4 Device: 14
Display: NORMAL SMOKE (ION) C-4 RISER ROOM 1 V000 M 031
Location: This detector is located in the C4 riser room 1 which is the airwall pocket at the C3/4 point dockside in C4 hall
11/18/2025 37
Alarm No. 416: Node 2: L04D16: Loop: 4 Device: 16
Display: NORMAL SMOKE (ION) C-4 PIZZA SERVE V000 M 051
Location: This detector is located in the serving area of the C4 hall Papa Johns pizza on the east wall of C4 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 417: Node 2: L04D17: Loop: 4 Device: 17
Display: NORMAL SMOKE (ION) C-4 E WOMENS RESTRM V000 M 051
Location: This detector is located in the housekeeping storage room in the womens restroom on the east wall of C4 hall Description: A Smoke Detector has gone off in this area.
Alarm No. 419: Node 2: L04D19: Loop: 4 Device: 19
Display: NORMAL SMOKE(PHOTO) HVU E-1 SUPPLY DUCT V000 M 037
Location: This detector is located inside the air handler in the ceiling at the far southend of C4 dock Description: A Smoke Detector has gone off in this area.
Alarm No. 420: Node 2: L04D20: Loop: 4 Device: 20
Display: NORMAL SMOKE (ION) C-4 EAST CONCESSIONS V000 M 030
Location: This detector is located in the C4 hall concessions stand on the east wall Description: A Smoke Detector has gone off in this area.
Alarm No. 421: Node 2: L04D21: Loop: 4 Device: 21
Display: NORMAL SMOKE (ION) C-4 EAST CONCESSIONS V000 M 034
Location: This detector is located in the C4 hall concessions stand on the east wall Description: A Smoke Detector has gone off in this area.
Alarm No. 422: Node 2: L04D22: Loop: 4 Device: 22
Display: NORMAL SMOKE (ION) BLDG B LEVEL 1 EAST V000 M 065 Building: B
11/18/2025 38
Location: This detector is located in the lobby of the B/C connector…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .