AMD 0001 21R1321 Rev DWGS.pdf
PDF 16 MB Posted
- Solicitation number
- N62742-21-R-1321
About this file
This solicitation is for the construction of a new Bachelor Officer Quarters tower at Naval Support Activity Marine Corps Base Guam. The project includes a multi-story housing tower with single-occupancy units, common areas, and support spaces. An attached common area wing and detached utility building will also be constructed. The estimated value of the contract is between $100-150 million. The work will be funded by direct cash contributions from the Government of Japan. The solicitation was issued on June 8, 2021, with an anticipated contract completion period of 760 calendar days. The North American Industry Classification System code for this opportunity is 236116 for new multifamily housing.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C-002
J -0
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
1. REQUEST WATER OUTAGES FROM THE NAVFACMAR BOSC SERVICE SUPPORT CENTER, (671) 333-2011 VIA THE CONTRACTING OFFICER'S REPRESENTATIVE, THIRTY (30) DAYS PRIOR TO THE DESIRED DATE
OF THE OUTAGE. ENSURE THAT APPROVAL HAS BEEN OBTAINED FOR THE OUTAGE PRIOR TO
PERFORMING THE WORK. ENSURE THE APPROPRIATE NAVFAC MARIANAS FACILITY MANAGER
NOTIFIES PERSONNEL LOCATED IN BUILDINGS AFFECTED BY THE OUTAGE UPON APPROVAL OF THE
OUTAGE. ALL WATER OUTAGES SHALL BE PERFORMED BY THE NAVFACMAR BOSC, UNLESS
OTHERWISE DIRECTED BY THE CONTRACTING OFFICER.
2. COORDINATE THE WATER OUTAGE DURATION WITH THE NAVFACMAR BOSC. WATER OUTAGES
AFFECTING AN INDIVIDUAL FACILITY SHOULD NOT EXCEED FOUR (4) HOURS. PROVIDE TEMPORARY WATER SERVICE TO AFFECTED FACILITIES WHEN WATER OUTAGES EXCEED FOUR (4) HOURS, UNLESS AN OUTAGE DURATION BEYOND FOUR (4) HOURS IS APPROPRIATE BY THE FACILITY OR HOUSING
MANAGER AND THE GUAM NAVAL BASE FIRE CHIEF.
3. PROVIDE NAVFACMAR BOSC FOURTEEN (14) DAYS NOTICE PRIOR TO CONNECTING TO ANY
WATERLINE. CONNECTION WORK SHALL BE PERFORMED IN THE PRESENCE OF THE CONTRACTING
OFFICER'S REPRESENTATIVE.
4. NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE THREE (3) WORKING DAYS PRIOR TO CONNECTING TO AN EXISTING NAVY WATER LINE OR DISINFECTING A NEW OR EXISTING LINE.
5. ALL NEW OR REPAIRED POTABLE WATER LINES, FIRE PROTECTION LINES THAT ARE CONNECTED TO
THE POTABLE WATER SYSTEM, IRRIGATION LINES THAT ARE UPSTREAM OF THE BACKFLOW
PREVENTION DEVICES AND AFFECTED PORTIONS OF EXISTING POTABLE WATER LINES SHALL BE
FLUSHED AND DISINFECTED.
6. DISINFECTION WORK SHALL BE PERFORMED IN THE PRESENCE OF THE CONTRACTING OFFICER'S
REPRESENTATIVE, NAVFACMAR PWD UTILITIES, AND NAVFACMAR EV.
7. DISINFECTION FOR REPAIR AND CONNECTIONS TO EXISTING LINES.
A. DISINFECTION PROCEDURES FOR REPAIRS/CONNECTION WORK SHALL BE AS INDICATED IN
AWWA C651 UNDER THE PARAGRAPH TITLED "DISINFECTION PROCEDURES WHEN CUTTING INTO
OR REPAIRING EXISTING MAINS" EXCEPT THAT A FIVE (5) PERCENT HYPOCHLORITE SOLUTION
SHALL BE USED.
B. ALL TAPPING SLEEVES SHALL BE DISINFECTED AS FOLLOWS:
a. THOROUGHLY CLEAN THE EXTERIOR SURFACE OF THE MAIN TO BE TAPPED, THE SURFACES
OF THE TAPPING SLEEVE AND THE SURFACES OF THE TAPPING EQUIPMENT THAT WILL COME
INTO CONTACT WITH THE WATER.
b. THOROUGHLY SWAB THE MAIN, THE TAPPING SLEEVE AND THE TAPPING EQUIPMENT WITH A
FIVE (5) PERCENT SODIUM HYPOCHLORITE SOLUTION.
c. ANY SURFACES THAT BECOME CONTAMINATED AFTER BEING DISINFECTED, SHALL BE
RECLEANED AND RESWABBED AS INDICATED ABOVE.
C. AFTER FINAL FLUSHING AND PRIOR TO PLACING NEW LINES IN SERVICE, BACTERIOLOGICAL
TESTS SHALL BE PERFORMED AS INDICATED IN AWWA C651 AND AS FOLLOWS:
a. STANDARD CONDITIONS: AT LEAST ONE SAMPLE SHALL BE COLLECTED FROM THE END OF
EACH NEW MAIN AND ONE FROM THE END OF EACH NEW BRANCH LINE. THE LOCATION OF
THE ADDITIONAL SAMPLES SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY
THE CONTRACTING OFFICER.
b. SPECIAL CONDITIONS: IF DURING CONSTRUCTION, TRENCH WATER HAS ENTERED THE LINE
OF IF IN THE OPINION OF THE CONTRACTING OFFICER EXCESSIVE QUANTITIES OF DIRT OR
DEBRIS HAVE ENTERED THE LINES, SAMPLES SHALL BE TAKEN AT INTERVALS OF
APPROXIMATELY 200 FEET AND SHALL BE IDENTIFIED BY LOCATION.
D. DISINFECTION OF MAINS AND BRANCH LINES SHALL BE REPEATED UNTIL SAMPLES SHOW THE
ABSENCE OF COLIFORM ORGANISMS.
E. FINAL BACTERIOLOGICAL TEST RESULTS, THAT SHOW THE ABSENCE OF COLIFORM ORGANISMS, SHALL BE PROVIDED TO THE CONTRACTING OFFICER'S REPRESENTATIVE AT THE FINAL
INSPECTION OF THE PROJECT OR PRIOR TO PLACING THE LINE IN SERVICE WHICHEVER OCCURS
FIRST. THE LOCATION WHERE THE BACTERIOLOGICAL SAMPLES WERE TAKEN SHALL BE
IDENTIFIED.
8. PROVIDE NAVFACMAR PWD THREE (3) SETS OF "AS-BUILT" DRAWINGS, VIA THE CONTRACTING
OFFICER.
9. WATER FROM HYDRO TESTING/DISINFECTION SHALL NOT BE DISCHARGED INTO THE STORM
DRAINAGE SYSTEM OR THE SEWER SYSTEM. WATER MAY BE DISCHARGED ONTO THE GROUND IN AN
UNPAVED AREA APPROVED BY THE CONTRACTING OFFICER, PROVIDED THAT THE WATER IS NOT
CONTAMINATED, HAS BEEN DECHLORINATED, WILL NOT ENTER THE STORM DRAINAGE OR SEWER
SYSTEM, AND WILL NOT CREATE A NUISANCE BY PONDING OR FLOODING.
10. WATERLINES TO BE ABANDONED MUST BE CAPPED CLOSEST TO THE MAIN WATERLINE DISTRIBUTION SOURCE. CAPPING OF WATERLINES FOR DEMO PROJECTS 1500mm FROM THE STRUCTURE WILL NOT
BE ALLOWED. ACTIVE DEAD-END WATERLINES WILL COMPROMISE WATER QUALITY PROMOTING
STAGNANT WATER AND DISSIPATION OF CHLORINE RESIDUAL, RESULTING IN POTENTIAL BACTERIAL GROWTH, NOV (NOTICE OF VIOLATION) AND FINES. PRIOR TO ABANDOMENT, PIPE SHALL BE FILLED
WITH FLOWABLE FILL CONCRETE.
WATER NOTES: GRADING NOTES:
1. ADEQUATE PROVISIONS SHALL BE MADE TO PREVENT SURFACE WATERS FROM DAMAGING THE CUT
FACE OF AN EXCAVATION OR THE SLOPED FACE OF A FILL. FURTHERMORE, ADEQUATE PROVISIONS
SHALL BE MADE TO PREVENT SEDIMENT-LADENT RUNOFF FROM LEAVING THE SITE.
2. THE CONTRACTOR SHALL NOT PERFORM ANY GRADING OPERATIONS THAT MAY CAUSE FALLING ROCKS, SOIL OR DEBRIS, IN ANY FORM, TO FALL, SLIDE OR FLOW INTO BASE DRAINAGE SYSTEMS OR
NATURAL WATER COURSES, OR ONTO ADJOINING PROPERTIES OR STREETS. SHOULD SUCH
VIOLATIONS OCCUR, THE CONTRACTOR MAY BE CITED AND THE CONTRACTOR SHALL IMMEDIATELY
MAKE ALL REMEDIAL ACTIONS NECESSARY AT NO ADDITIONAL COST TO THE GOVERNMENT.
3. WHERE APPLICABLE AND FEASIBLE, THE MEASURES TO CONTROL EROSION AND OTHER POLLUTANTS
SHALL BE IN PLACE BEFORE ANY EARTH-MOVING PHASE OF THE GRADING COMMENCES.
4. ALL SLOPES AND EXPOSED AREAS SHALL BE SODDED OR PLANTED AS SOON AS FINAL GRADES HAVE
BEEN ESTABLISHED. PLANTING SHALL NOT BE DELAYED UNTIL ALL GRADING WORK HAS BEEN
COMPLETED. GRADING TO FINAL GRADE SHALL BE CONTINUOUS AND ANY AREA WITHIN WHICH WORK
HAS BEEN INTERRUPTED OR DELAYED SHALL BE PLANTED.
5. FILL ON SLOPES STEEPER THAN 5: 1 (HORIZONTAL: VERTICAL) SHALL BE KEYED.
6. THE LIMITS OF THE AREA TO BE CLEARED, CLEARED AND GRUBBED, AND/OR GRADED SHALL BE
FLAGGED BY THE CONTRACTOR BEFORE COMMENCEMENT OF THE GRADING WORK.
7. ALL GRADING OPERATIONS SHALL BE PERFORMED IN CONFORMANCE WITH THE APPLICABLE
PROVISIONS OF THE EPA WATER POLLUTION CONTROL AND WATER QUALITY STANDARDS AND THE
NPDES PERMIT FOR THE PROJECT.
8. TEMPORARY EROSION CONTROL PROCEDURES SHALL BE SUBMITTED TO THE CONTRACTING
OFFICER FOR APPROVAL PRIOR TO APPLICATION FOR THE GRADING PERMIT.
9. ALL EXPOSED AREAS THAT ARE NOT AT FINAL GRADE AND ARE LEFT TO BE EXPOSED LONGER THAN TWO (2) WEEKS SHALL BE PROTECTED FROM EROSION AND SEDIMENTATION TO THE SATISFACTION
OF THE CONTRACTING OFFICER.
10. LOCATIONS OF UNDERGROUND UTILITIES ARE FROM SURVEY INFORMATION AND AS-BUILT DRAWINGS.
FIELD-VERIFY ALL LOCATIONS AND DEPTHS OF UTILITIES PRIOR TO BEGINNING CONSTRUCTION AND
EXERCISE PROPER CARE IN EXCAVATING IN THE AREA.
11. DURING WET WEATHER PERIODS, SEQUENCE CONSTRUCTION IN A MANNER THAT MINIMIZES IMPACT
ON OPEN EARTHWORK AND COMPACTION OPERATIONS.
12. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER THAT THE J-034 PROJECT SITE HAS BEEN CLEARED OF MEC BY THE J-001B UTILITIES AND SITE IMPROVEMENTS PROJECT TO A DEPTH
OF 4 FEET BELOW ROUGH GRADE. AT AREAS WHERE BEDROCK WAS ENCOUNTERED, MEC
CLEARANCE IS COMPLETE.
1. HORIZONTAL AND VERTICAL CONTROLS WERE BASED ON 1993 GUAM GEODETIC NETWORK (GGN)
COORDINATES AND MONUMENTS GGN 80 (AKA 3.11) ALONG ROUTE 3 AND SOUTHWEST OF THE
PROJECT SITE, WITH THE FOLLOWING PROPERTIES (IN METERS):
GGN80 NAD83 (GGN) COORDINATES
NORTHING: 208,698.2624
EASTING: 111,136.9200
GGN80 WGS84 UTM55N COORDINATES (USED FOR J-023 AND J-034 PROJECT)
NORTHING: 1,502,144.739
EASTING: 267,668.2800
ELEVATION: 137.813 (MSL)
GGGN79 NAD83 (GGN) COORDINATES
NORTHING: 208,327.0570
EASTING: 110,843.2790
GGN79 WGS84 UTM55N COORDINATES (USED FOR J-023 AND J-034 PROJECT)
NORTHING: 1,501,776.1590
EASTING: 267,371.1490
ELEVATION: 133.900 (MSL)
BASIS OF BEARING (GGN79 TO GGN80)
WGS:N 38° 52' 26.56" E, LENGTH= 473.43
GGN: N 38° 20' 44.38" E, LENGTH= 473.31
7/14/2021
CG103
J -0
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
4030201010
1:500
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN
IN CALLOUT/NOTES ARE IN METERS UNLESS
OTHERWISE NOTED.
PLAN
NORTH
PLAN
NORTH
CG103
SCALE:
J-034 GRADING AND DRAINAGE PLAN 11:500
LEGEND:
APPROXIMATE GRADING LIMITS
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
EXISTING CONTOUR WITH ELEVATION
PROPOSED CONTOUR WITH ELEVATION
EXISTING DRAINAGE INLET
X
X
DIRECTION OF SLOPE
1. EXISTING SITE FEATURES ARE CONCEPTUAL. THE EXISTING
SITE FEATURES ARE BASED UPON THE FINAL DESIGN FOR
PROJECT J-001B.
2. VERIFY LOCATION AND INVERT OF EXISTING UTILITIES PRIOR
TO CONSTRUCTION.
3. UNLESS FEATURES ARE IDENTIFIED FOR REMOVAL, THE
FEATURES MUST REMAIN. PROTECT EXISTING FEATURES TO
REMAIN.
NOTES:
1. EXISTING SITE FEATURES ARE CONCEPTUAL. THE EXISTING
SITE FEATURES ARE BASED UPON THE FINAL DESIGN FOR
PROJECT J-001B.
2. VERIFY LOCATION AND INVERT OF EXISTING UTILITIES PRIOR
TO CONSTRUCTION.
3. UNLESS FEATURES ARE IDENTIFIED FOR REMOVAL, THE
FEATURES MUST REMAIN. PROTECT EXISTING FEATURES TO
REMAIN.
4. SEE ENLARGED GRADING PLAN FOR PAVEMENT SURFACE
ELEVATIONS.
J-023 SITE BOUNDARY
BOQ B BLDG
(FFE=140.000)
PAVILION
(FFE=139.250)
UTILITY BLDG
(FEE=139.000)
BBQ PAVILION
(FFE=139.050)
TRASH/RECYLING
ENCLOSURE
PAVILION
(FFE=142.620)
BIKE PAVILION
(FFE=139.800)
J-034 SITE
BOUNDARY
CG421
CG423
CG423
CG422
KEYNOTES:*
CG203
CG203
CG203
CG203
CG203
CG203
1. 300MM HDPE DRAINAGE PIPE
2. 450MM HDPE DRAINAGE PIPE
3. NOT USED
4. NOT USED
5. NOT USED
6. NOT USED
7. CONCRETE HEADWALL WITH FLARED WINGS, SEE SHEET
CG501, DET C2
8. STORM DRAIN MANHOLE, SEE SHEET CG501, DET C4
9. CHECK DAM, SEE SHEET CG503, DET A2
10. GRATED INLET, TYPE 1, SEE SHEET CG501, DET A4
11. J-034 RETENTION BASIN OUTLET STRUCTURE, SEE CG502,
DET A1
12. NOT USED
13. GRASS SURFACED STORMWATER TREATMENT SECTION, SEE
SHEET CG502, DET A4
14. NOT USED
15. NOT USED
16. NOT USED
17. GRASSY WIDE SWALE, SEE PLANS FOR LENGTH (L) SEE
SHEET CG503, DET C1
18. GRASSY TRAP-SWALE, SEE PLANS FOR LENGTH (H) SEE
SHEET CG503, DET C1
19. STONE DIAGHRAGM, SEE PLANS FOR LENGTH (L), SEE SHEET
CG503, DET A5
APPROXIMATE
GRADING LOCATION
10SDS-13
SDS-16
1 SDP-15
10SDS-12
8 SDS-141SDP-13
1SDP-14
12SDS-22
2SDP-22
SDS-23
EXISTING
INLET
2SDP-21
STONE
APRON
1 SDP-10
2SDP-20
12SDS-21
11SDS-20
1 SDP-11
2 SDP-12
40 M (L)
30 M (L)
39 M (L)
92 M (L)
67 M (L)18
45 M (L)
52 M (L)
CG502
40 M (L)
1 M (H)
0.3 M (H)
0.3 M (H)
0.3 M (H)
0.3 M (H)
9 0.3 M (H)
BASE 2M (W) X 10M (L)
D E P A R T M E N T O F T H E N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
PA
C
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
PN
JCJHDH
B
IM
J-a n d J-
J-
B O Q A R C H r1 .r vt
:5 :2 A M
B O
Q B
E
LE
V
A
TI
O N
S
A-213
A M D
M E C H
Y A R D
W A
LL
G A
TE
E D
IT
SHEET
NAVFAC DRAWING NO.
OF
A-213
SHEET
NAVFAC DRAWING NO.
OF
A-213
17268438 4434434251164
SEALSEAL
P A R T M E N T O F T H E N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
PA
C
IF
IC
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
, G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
972483
PN
DH JH JC
B
IM
J-a n d J-
J-
B O Q D E
TA
IL
S r1 .r vt
:2 :0 P M
E X
TE
R
IO
R
D E
TA
IL
S
FO
U
N D
A
TI
O N
A N
D M
IS
C
A-512
17255405
A M D
C U R B
A D D E D
R. CONTR. NO.
C DRAWING NO.
FORM REVISION: 30 APRIL 2015
OF
CT NO.: 972483
A-512
17255405
R. CONTR. NO.
C DRAWING NO.
FORM REVISION: 30 APRIL 2015
OF
CT NO.: 972483
A-512
17255405 17268465
1641226
4434434278191
05/11/21
P A R T M E N T O F T H E N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
PA
C
IF
IC
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
, G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
972483
PN
DH JH JC
B
IM
J-a n d
J-
J-
B O Q D E
TA
IL
S r1 .r vt
:2 :0
P M
P A
R
TI
TI
O
N T
Y P
E S
A-591
17255417
A M D
P A R
TI
TI
O N
N O
TE
S C U R B
E D
IT
S
R. CONTR. NO.
C DRAWING NO.
FORM REVISION: 30 APRIL 2015
OF
ECT NO.: 972483
A-591
17255417 17268477
1641226
4434434290203
05/11/21
P A R T M E N T O F T H E N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
PA
C
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
PN
JCJHDH
B
IM
J-a n d
J-
J-
B O Q A R C H r1 .r vt
:5 :2
A M
B O
Q B
D
O O
R S
C H
E D
U
LE
G
A
TE
S C
H E
D U
LE
A-603
A M D
M E C H
Y A R D
W A
LL
G A
TE
E D
IT
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 30 APRIL 2015
OF 434
A-603
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 30 APRIL 2015
OF 434
A-603
17268478 4434434291204
SEALSEAL
RRE
VD
AT
E
PL
O
TT
ED
C U se rs k a c h o n D o c u m e n ts B O Q J-
M e c h v1 k liu Y W S Q .r vt
:4 :0
A M
H
A W A I I, U.S
.A
I CERTIFY THAT THIS DRAWING WAS PREPARED BY
ME OR UNDER MY DIRECT SUPERVISION.
D E P A R T M E N T O F T H E N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
N
AV
FA
C
PA
C
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
LE
OCKLKL
B O
Q B
O
V E
R A
LL
M
E C
H A
N
IC
A L
P
LA
N
M-103 17268543
A M E N D M E N T
S
LO
P E D
C H W S R
A N
R A
IN
B O X
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text
AutoCAD SHX Text U
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
I CERTIFY THAT THIS DRAWING WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION.
AutoCAD SHX Text
AMENDMENT 0001 - ADDED MECH. DETAIL
AutoCAD SHX Text 06/30/21
W W
W
W W W W W W W W W W W W W W
W W
W W
W W
W W
W W
W
WWW
W W
W W
W W
W
W
WWWWWWWW
W
W
W W
W W
W W W W
W W
W W
W
W
W
F
F F F F
W W
SANSANSAN
SA
N
SAN SAN SAN SAN SAN SAN SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SA
N
SA
N
SANSAN
SA
N
SA
N
F
F
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
WWWWWWW
W
W
WWWWWWW
W
W
WWWWWWW
W
W
WWWWWWW
W
W
WWWWWWW
W
W
WWWWWWW
W
W
WWWWWWW
W
CU
CU
W W
SA
N
W W
SA
N
W
W W
SA
N
M
M
M
MH P574-8C
MH P574-8B
EHH
UTILITY BLDG
PAVILION
BBQ PAVILION
BOQ B BUILDING
SHH
SHH
ES
ES
ES
ES
ES
ES ES
ES
ES
11 11
10 10
E
MH P574-8D
ES
10ES ES ES
ES ES ES
10 10
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES ES
ES
ES
ES
ES
ES
ES
ES
ES
ESES
ES
ES
ES
ES
ES
9 9
ES
ES
ES
ES
ES
ES
ES
ES
11 11
ES
ES
ES
ES
ES
E
E
ES
E
PAVILION
SDSDSD
BOQ B - ELECTRICAL SITE PLAN
(E) MH P574-8
(E) MH P574A-2
(E) SW P574A-2
(E) SW P574-8
KEY PLAN
NOT TO SCALE
ES101
TYPICAL
E-404
E-404
TYPICAL
E-104
E-124
E-404
E-404
TO SWITCHBOARD "4MDS-BB"
GENERAL NOTES:
FOR ENLARGED PLAN, SEE & .
FOR ENLARGED PLAN, SEE & .
TO SWITCHBOARD "4MDS-UB"
FOR ENLARGED PLAN, SEE & .
M
L
TO ECB-EMB AND ECB-GBB
TO GENERATOR WIRE GUTTER
MH P574-8A
P P
SP SP
E-404
E-404
FOR ENLARGED PLAN, SEE & .
4L1L-9
VIA LC "LC-EL"
4L1L-10
VIA LC "LC-EL"
4L1L-11
VIA LC "LC-EL"
P P
SP SP
P P
SP SP
P P
SP SP
SEE ONE LINE DIAGRAM E-601 AND E-602 FOR CONDUIT AND WIRE SIZES AND
QUANTITIES.
LIGHT LINES INDICATE INFRASTRUCTURE CONSTRUCTED UNDER J-001B
FINEGAYAN UTILITIES AND SITE IMPROVEMENTS PHASE 1 PROJECT. DARK
LINES INDICATE NEW.
P P
SP SP
S
B O
Q B
E
LE
C
TR
IC
A L
S
IT
E P
LA
N
ES101
PAD MOUNTED TRANSFORMER "UB"
4L1L-8
VIA LC "LC-EL"
4L1L-12
VIA LC "LC-EL"
SP
S S S
S S SSP
S S S
S S S
S
TO PANEL "2DP1"
SP
S S S
S S S
VIA CT CABINET, SEE ONE LINE DIAGRAM FOR INFORMATION.
NOTES:
TO PAVILION LIGHTING.2
2 3
4L1L-13
S S
S S S
2L1P-27
TO PAVILION RECEPTACLE.3
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C P
AC
IF
IC
SEAL
J -0
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
AMIA/JF
1641226
05/11/21
DATE
JC
P. NISHIZAKI
MN/KO
JS
NP/RS
OF
EN
GI
N
E
E R
NAL
P R O
F
ESS IO
R
MARIA
N O
A B
NE
(ELECTRICAL)
No.1259
ET
ACIFITRE
C
MAUG
EXP.
V.
April 30,2022
SEAL
WR
WR
WR WR
WR WR
2L1P-34
CT CABINET
S27mmC, FOR AMI METER POWER
BOQ B BUILDING AMI METER
PAD MOUNTED TRANSFORMER "BB"
2L1P-32
TRANSFORMER ENCLOSURE ENLARGED PLAN 2
ES101
FOR ENLARGED PLAN, SEE .
2L1P-37
E-504
RECEPTACLE MOUNTED INSIDE ICS WATER METER ENCLOSURE. SEE TELECOM
PLANS FOR DETAILS
5 1-103mm EMPTY CONDUIT FOR FUTURE MICROGRID CONTROL, SEE FOR CONDUIT STUB-OUT MARKER.
E-606
6 INSTALL TOGETHER WITH ICS TELECOM OUTLET INSIDE THE 18"X18"12"D
LOCKABLE ENCLOSURE. NEMA 4X, 316 SST.SEE FOR
ELEVATION DETAIL.
SP
TO ATS-GUB
17268616
E-504
7 STUBOUT MARKER. SEE FOR DETAIL.
SP
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
PLAN
NORTH
P P
SP
P P
SP
P P
SP SP
S
WR
E-124
8 FOR LOCATION OF UTILITY BUILDING AMI METER AND CT CABINET. SEE .
MECH YARD
MECH ROOM
GENERATOR
TRANSFORMER
ELEC
FIRE RISER
TELECOM
WATER SOFTENER
131A
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :2
P M
B O
Q B
U
TI
LI
TY
B
U
IL
D
IN
G L
IG
H
TI
N
G P
LA
N
Z
O N
E E
E-104
17268622
NOTES:
GENERAL NOTES:
AM
D
AD
DE
D
NO
TE
7/
TRANSFORMER
MECH ROOM
ELEC
139 GENERATOR
MECH YARD
WATER SOFTENER
131A
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :2
P M
B O
Q B
U
TI
LI
TY
B
U
IL
D
IN
G P
O W
E R
P
LA
N
Z O
N E
E
E-124
17268630
NOTES:
GENERAL NOTE:
AM
D
RE
VI
SE
D
C
IR
C
UI
T H
OM
ER
UN
A
ND
N
OT
ES
7/
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :3
P M
B O
Q B
U
TI
LI
TY
B
U
IL
D
IN
G L
IG
H
TN
IN
G P
R O
TE
C
TI
O
N P
LA
N
Z
O N
E E
E-143
17268636
THE COMPLETED INSTALLATION SHALL MEET NFPA 780. THE UL LIGHTNING PROTECTION INSPECTION CERTIFICATE
MUST BE FURNISHED TO THE GOVERNMENT UPON COMPLETION.
ALL METAL BODIES WITHIN 1828mm OF LIGHTNING PROTECTION SYSTEM OR THAT PROTRUDE PASSED THE ZONE
OF PROTECTION MUST BE BONDED TO LIGHTNING PROTECTION SYSTEM.
ROOF TOP EQUIPMENT NOT SHOWN ON THIS DRAWING MUST BE PROTECTED AS REQUIRED TO MEET THE REQUIREMENTS LISTED ABOVE INCLUDING THE INSTALLATION OF AIR TERMINAL AND OR BONDING.
ALL LIGHTNING CONDUCTORS MUST MAINTAIN A HORIZONTAL OF DOWNWARD PATH. ALL BENDS IN THE CONDUCTOR MUST HAVE A RADIUS BEND OF 203mm OR GREATER, AND MUST HAVE AN ANGLE BEND NOT LESS
THAN 90 DEGREES OR GREATER.
NOTES:
PROVIDE GROUND TEST WELL. SEE DETAIL .
INSTALL DOWN CONDUCTOR IN PVC CONDUIT
CONCEALED WITHIN CONCRETE WALL.
GENERAL NOTES:
COORDINATE FINAL RATING OF LOOP CONDUCTOR WITH UTILITY SITE PLANS. ADJUST AS NECESSARY AT NO
ADDITIONAL COST TO THE GOVERNMENT.
AM
D
RE
VI
SE
D
LI
GH
TN
IN
G
PR
OT
EC
TI
ON
P
LA
N
7/
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :5
P M
TY
P
IC
A
L R
O O
M E
LE
C
TR
IC
A L
P
LA
N
E-401
17268637
NOTES (APPLICABLE TO ENTIRE SHEET):
AM
D
RE
VI
SE
D
LI
GH
T
FI
XT
UR
E C
IR
C
UI
TI
NG
7/
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :1
P M
B O
Q B
P
A V
IL
IO
N E
N
LA
R G
E D
P
LA
N S
E-404
17268640
GENERAL NOTE:
AM
D
AD
D
ED
N O
TE
7/
NOTE:
ELEVATOR
E01
ELEVATOR
E01
ELEC
GENERATOR
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :1
P M
B O
Q B
U
TI
LI
TY
B
U
IL
D
IN
G E
LE
C
TR
IC
A L
R O
O M
A N
D E
LE
V
A
TO
R P
IT
E
N
LA
R G
E D
P
LA
N
E-405
17268641
NOTES:
NOTES:GENERAL NOTES:
GENERAL NOTE:
AM
D
ED
IT
ED
N
OT
E
NU
M B
ER
7/
203mm
3m m
GENERAL NOTES:
NOTES:
TYPICAL
21mmC, 120mm2 BARE COPPER
LIGHTNING ARRESTER GROUND
102mm RAISED CONCRETE PAD
OUTLINE OF TRANSFORMER
CONCRETE
ENCLOSURE
REFER TO CIVIL DRAWINGS FOR DETAIL OF
CONCRETE ENCLOSURE AND CONCRETE PAD.
VERIFY EXACT DIMENSION WITH EQUIPMENT SUPPLIER.
20mmØ X 3040mm GROUND ROD. AUGER HOLE 102mm DIAMETER X 3658mm FILL HOLE WITH BENTONITE AND INSTALL GROUND ROD IN THE CENTER OF THE HOLE. TOP OF ROD SHALL BE 305mm
BELOW GRADE.
120mm2 BARE COPPER 610mm MINIMUM BELOW GRADE.
BOND TO COUNTERPOISE GROUND.
BOND ENCLOSURE FOUNDATION REBAR TO GROUND.
21mmC,12Omm2 BARE COPPER
BOND TO ENCLOSURE & CABLE
SHIELD
TRANSFORMER FRONT
25mm2 BARE COPPER TO
TRANSFORMER
GROUND RING (TYPICAL OF 2)
mm
914mm 1219mm 1219mm 914mm mm
4m m mm22 mm mm 1829mm
GROUND
ITEM
COVER WITH ENGRAVEMENT "GROUND"
PULL SLOT
BOX
DESCRIPTION
CL
BC GROUND WIRE
EXOTHERMIC WELD
GROUND ROD 20mm X 3040mm5
NOTES:
POLYMER CONCRETE REINFORCED HEAVY-WEAVE FIBERGLASS
HANDHOLE 356mm X 267mm X 323mm OPEN BOTTOM
CONCRETE RING AROUND BOX 27.6 MPa
COMPACTED EARTH
TRAFFIC BEARING TYPE BOX WITH HEAVY DUTY TRAFFIC RATED CAST IRON COVER.
2 AUGER HOLE 102mm DIAMETER X 3658mm. FILLE HOLE WITH BENTONITE AND INSTALL GROUND ROD IN THE CENTER OF THE HOLE. TOP OF ROD SHALL BE 305mm BELOW
GRADE.
ROOF TOP
COPPER LOOP
CABLE HOLDER
AIR TERMINAL
BARE Cu
CONDUCTOR
2m m
4m m
FINISH GRADE
SELECTED BACKFILL
FILL WITH RED EARTH
(TOP SOIL) 76mm MIN. ALL AROUNDGROUND WIRE
1/0 BARE COPPER
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :2
P M
M
IS
C E
LL
A
N E
O U
S D
E
TA
IL
S
E-502
17268643
AM
D
C H
AN
GE
D
DE
TA
IL
T
AR
GE
T
7/
2m m
19mm CHAMFER
FIN. GRADE
ANCHOR BOLTS
CONDUIT
CONCRETE BASE, SEE
CIVIL DRAWINGS
"LED BOLLARD"
GENERAL NOTES:
SUBMIT SHOP DRAWING TO CONTRACTING
OFFICER FOR REVIEW AND APPROVAL.
FOR LIGHT FIXTURE REQUIREMENTS, SEE
LIGHT FIXTURE SCHEDULE.
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :3
P M
M
IS
C E
LL
A
N E
O U
S D
E
TA
IL
S
E-503
17268644
AM
D
R
EV
IS
ED
P
AR
K
IN
G
LI
G H T D
ET
AI
L
7/
GATE POST GROUNDING
914 914
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :3
P M
M
IS
C E
LL
A
N E
O U
S D
E
TA
IL
S
E-504
17268645
GENERAL NOTE:
AM
D
C H
AN
G
ED
D
ET
AI
L
TA
R G
ET
7/
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :4
P M
P R
IM
A
R Y
M A
N H
O
LE
D E
TA
IL
S
E-506
17268647
AM
D
R
EV
IS
ED
M
AN
H O
LE
D
ET
AI
L
7/
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"2L#DB"(1ST TO 5TH FLR.) 208/120V 3 4W 18,000 AIC
12.0
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
12.01 2
PANEL "LCA#12"2/100 2/0
10.0 10.0
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
PANEL "LCA#16"
PANEL "LCA#15"
PANEL "LCA#14"
2/100
PANEL "LCA#08"
PANEL "LCA#09"
PANEL "LCA#10"
PANEL "LCA#07"
PANEL "LCA#11" PANEL "LCA#13"
87.8
220.3 KVA
258.1 A
64.0
93.0 KVA
68.5
CALCULATED LOAD:
1/0 2
SPARE--
SPARE
PFB
2/0
PROVIDE #4 GROUNDING CONDUCTOR.
12.0 12.0
10.0 10.0
10.0 10.0
10.0 10.0
10.0 9.8
12.0 12.0
12.0 12.0
12.0 12.5
PROVIDE #2 GROUNDING CONDUCTOR.
SEE CONDUIT SIZE FOR TABLE.
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
208/120V 3 4W 10,000 AIC
EF-A
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
EF-B
SEE ONE LINE DIAGRAM FOR SIZE.
"2L5PA" (5TH FLR)
11.9
35.7 KVA
95.5 A34.4 KVACALCULATED LOAD:
3.0
1.31.3 1.31.3
1.31.3
- 3/20
DEF-A
KEF-A
SPARE
DEF-B
KEF-B
1/20 - SPARE
PFB
10 3/25
2 3/50
4 3/35
- 1/20
3/25 10
3/35
3/35
2.1
PROVIDE #4 GROUNDING CONDUCTOR.
PROVIDE #2 GROUNDING CONDUCTOR.
29 30
SPARE
11.9 11.9
3.0 2.1
3.0 2.1
2.1 2.1
2.1 2.1
2.1 2.1
PROVIDE #10 GROUNDING CONDUCTOR.
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
480/277V 3 4W 35,000 AIC
ELEVATOR - 1
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
XFMR "TGTR"
SEE ONE LINE DIAGRAM FOR SIZE.
"4GBB"
27.6
67.3 KVA
86.4 A
19.1
71.8 KVA
20.6
CALCULATED LOAD:
0.82.2 0.42.9
0.72.2
12.59.7 4.99.7
5.99.7
PANEL "4L1L"
PANEL "4L3L"
PANEL "4L5L"
PFB
SPARE 1/20 SPARE-1/20
PANEL "4L2L"
PANEL "4L4L"
3/50 - SPARE
SPD
0.8 0.8
0.8
0.4 0.4
0.4
0.7 0.7
0.7
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"2GTR" 208/120V 3 4W 10,000 AIC
RECEP (RM. 126) 12
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
RECEP - AACS/IDS GUTTERBOX (RM. 126)
SPD
1.5
0.6
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
SEE ONE LINE DIAGRAM FOR SIZE.
CALCULATED LOAD:
12.5
23.3 KVA
64.7 A
4.9
23.3 KVA
5.9
PA CABINET (RM. 126)
RECEP - CCTV GUTTERBOX (RM. 126)
TELECOM CABINET (ESS COMPARTMENT)
TELECOM CABINET (ESS COMPARTMENT)
ESS CABINET (RM. 113)
PA CABINET (RM. 118)
GFGI CCTV CABINET (RM. 118)
RECEP-GTC (RM. 118)
SPARE
PANEL "2GTC4"
PANEL "2GTC2"
PFB
0.2
0.5 0.2
0.2 0.3 0.3
0.1
0.5 0.5
0.5 0.5
0.5 0.5
0.2 0.2
121/20
RECEP - AACS/IDS GUTTERBOX (RM. 126)
TELECOM CABINET (ICS COMPARTMENT)
TELECOM CABINET (ICS COMPARTMENT)
VAV-126
ESS CABINET (RM. 111)
PA CABINET (RM. 111)
GFGI CCTV CABINET (RM. 111)
RECEP-GTC (RM. 111)
PANEL "2GTC5"
PANEL "2GTC3"
1/20
TELECOM CABINET (VOICE/DATA/OSP)
TELECOM CABINET (VOICE/DATA/OSP)
0.3 0.3
0.6 0.6
2.0 2.0
0.4 0.4
2.0 2.0
0.4 0.4
1.0 1.0
1.0 1.0
- SPARE
0.6
TELECOM CABINET (GOV EQUIPMENT)
TELECOM CABINET (GOV EQUIPMENT)
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"LC"_____" 208/120V 1 3W 10,000 AIC
LIGHTING - UNIT 12 1/20
22.3
71.2 A
KVA
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B
1 2
RECEPS. - BEDROOM1/20 12
SEE ONE LINE DIAGRAM FOR SIZE.
UNIT ROOM NUMBER.
AFCI TYPE CIRCUIT BREAKER.
RECEPS - KITCHEN, LIVING
SPARE
DRYER
PFB
- COUNTERTOP
- RESTROOM
VAV
2/30 6
2/50 RANGE
-- PFB
SPARE-
- LAUNDRY
- COUNTERTOP
- REFRIGERATOR
- GARBAGE DISPOSAL
- EXHAUST FAN
0.3 1.5
1.3 0.6
0.5 1.0
0.2 1.0
- 1.2
0.1 0.1
1.5 -
2.5 4.0
2.5 4.0
14.8
12.5
9.8
CALCULATED LOAD:
KVA
KVA
WASHER
AFCI AND GFCI TYPE CIRCUIT BREAKER.
SPARE -
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"4EM" 480/277V 3 4W 35,000 AIC
XFMR "TEM"
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
ELEVATOR -2
9.75.7 3.6
-0.1
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______" CALCULATED LOAD:
15.5
42.3 KVA
50.8 A
13.7
42.2 KVA
13.1
SPD
SPARE
PFB
1/20
SPARE
10LIGHTING - MACHINE ROOM (601)
SPARE
3/30
1/20
- ELEVATOR PIT/HOISTWAY 1
- ELEVATOR PIT/HOISTWAY 2
9.7 9.73.0
0.4 0.4
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
208/120V 3 4W 10,000 AIC
ESS CABINET (RM #18) 8 1/20
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
ESS CABINET (RM #11)1/20 80.50.5
0.20.2
0.50.5 0.50.5
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
"2GTC#" (2ND TO 5TH FLR.)
2.0
3.4 KVA
9.4 A
0.4
3.4 KVA
1.0
CALCULATED LOAD:
RECEP-GTC (RM #18)
PA CABINET (RM #18)
GFGI CCTV CABINET (RM #18)
SPARE
PFB
RECEP-GTC (RM #11)
PA CABINET (RM #11)
GFGI CCTV CABINET (RM #11)
SPARE
SPD
3/30
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"LC"_____" 208/120V 1 3W 10,000 AIC
LIGHTING - UNIT 12 1/20
23.5
71.2 A
KVA
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B
1 2
RECEPS. - BEDROOM1/20 12
SEE ONE LINE DIAGRAM FOR SIZE.
UNIT ROOM NUMBER.
AFCI TYPE CIRCUIT BREAKER.
RECEPS - KITCHEN, LIVING
STACKABLE WASHER/DRYER
PFB
- COUNTERTOP
- RESTROOM
VAV
2/30 6
2/50 RANGE
-- PFB
SPARE-
- LAUNDRY
- COUNTERTOP
- REFRIGERATOR
- GARBAGE DISPOSAL
- EXHAUST FAN
0.3 1.5
1.5 0.6
1.5 1.0
0.2 1.0
- 1.2
0.1 0.1
2.5 4.0
2.5 4.0
14.8
12.0 10.0
CALCULATED LOAD:
KVA
KVA
SPARE - -
AFCI AND GFCI TYPE CIRCUIT BREAKER.
SPARE -
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"2EM1" 208/120V 3 4W 10,000 AIC
RECEPS - ELEVATOR PIT 12 1/20
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
ESP-11/20 101.20.8
1.20.8
1.01.0
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______" CALCULATED LOAD:
5.7
12.3 KVA
33.7 A
3.6
12.2 KVA
3.0
- MACHINE ROOM
CAB LIGHTING & RECEP (ELEVATOR 1)
CAB AC & VENTILATION (ELEVATOR 1)
SPARE
PANEL "2BFP"
ESP-2
CAB LIGHTING & RECEP (ELEVATOR 2)
CAB AC & VENTILATION (ELEVATOR 2)
ELEVATOR CALL (MCP)
SPARE
PFB
1.01.0 0.2
PFB
1.7 1.4
1.0
SPD
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
CALCULATED LOAD:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
208/120V 3 4W 10,000 AIC
FMCP 12 1/20
1.7
4.1 KVA
11.4 A
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
1.4
BRK
POLE
BRK
POLE
B C
1.0
1 2
RAP (3RD FLOOR)1/20 100.20.5
0.20.2 0.2
-0.2
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
"2BFP"
RAP (1ST FLOOR)
FEP (1ST FLOOR)
FIP, TRANSCEIVER, TRANSMITTER
RAP (2ND FLOOR)
RESCUE ASSISTANCE (1ST FLOOR)
SPARE
PFB
FEP (3RD FLOOR)
SPARE
SPD
- 3/30
4.1 KVA
FEP (2ND FLOOR)
RESCUE ASSISTANCE (2ND FLOOR)
RESCUE ASSISTANCE (3RD FLOOR)
RESCUE ASSISTANCE (4TH FLOOR)
RESCUE ASSISTANCE (5TH FLOOR)
0.20.2 0.20.2
0.20.2 0.20.2
0.20.2
0.2
0.2 0.2
RAP (4TH FLOOR)
FEP (4TH FLOOR)
RAP (5TH FLOOR)
FEP (5TH FLOOR)
RAP (LOWER ROOF)
FEP (LOWER ROOF)
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
CALCULATED LOAD:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
208/120V 3 4W 10,000 AIC
RECEP (RM #05) 12 1/20
2.6
7.5 KVA
21.1 A
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
2.7
BRK
POLE
BRK
POLE
B C
2.2
1 2
VAV #051/20 120.11.1
0.60.6
0.60.6 0.50.5
0.50.5 0.50.5
0.20.2 -0.5
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
"2CTR#"(1ST TO 5TH FLR.)
TELECOM CABINET (DATA)
TELECOM CABINET (DATA)
VOICE CABINET (RM #17)
DATA CABINET (RM #17)
CATV CABINET (RM #17)
RECEP-CTC (RM #17)
SPARE
PFB
TELECOM CABINET (VOICE)
TELECOM CABINET (VOICE)
VOICE CABINET (RM #10)
DATA CABINET (RM #10)
CATV CABINET (RM#10)
RECEP-CTC (RM #10)
SPARE
SPD
- 3/30
7.6 KVA
8 8
12CATV CABINET (RM #05)
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 30 APRIL 2015
REV
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
N A
VF
A
C P
A C
IF
IC
M
AK
AL
AP
A, H
AW
AI
I
FIRE PROTECTION
AS SHOWN
RANDALL TORIGOE
MARFORPAC DPRI MILCON LEAD
RE
VD
AT
E
PL
O
TT
ED
N
AV
FA
C
P
AC
IF
IC
05/11/21
SEAL
J-
B
A C
H E
LO
R
O
FF
IC
E
R Q
U A
R
TE
R S
-B U
S N
A V
S U
P P
A C
T M
C B
G U
A M
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK
AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO
INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.
DATE
IF SHEET IS LESS THAN 559 X 864
REDUCED PRINT. USE GRAPHIC
SCALES
JC
P. NISHIZAKI
MN/KO
1641226
JS
AMNP/RSIA/JF
C U se rs n p a c ia D o c u m e n ts M e d ic a l
C lin ic J-
B O Q E
LE
C r1 n e d ie .r vt
:4 :4
P M
P A
N E
LB
O
A R
D S
C H
E D
U
LE
E-609
17268656
GENERAL NOTES:
CONDUIT SIZE TABLE
WIRE SIZE CONDUIT SIZE
1/0 2/0
35mmC 35mmC 41mmC 53mmC
AM
D
RE
VI
SE
D
W
IR
E
SI
ZE
7/
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"2UB" 208/120V 3 4W 10,000 AIC
RECEPS (ELEC RM 133) 12 1/20
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
RECEPS (DDC)1.1
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
SEE ONE LINE DIAGRAM FOR SIZE.
5.4
13.4 KVA
16.1 A5.8 KVACALCULATED LOAD:
0.2
4.0 4.0
0.6 1.5
1.3 0.4
0.4 0.4
0.9
1.2 -
121/20
(RM 131A)
(EXTERIOR)
(MECH RM 131)
AHU-M
12 3/20
(DDC)
(FIRE RISER 141)
(FIRE RISER 141)
(GENERATOR 140)
LIGHTING CONTROLLER
(MECH RM 131)
(DDC)
0.2
0.2
0.2
1.2 1.2
0.2
AMI METER (ELECTRIC)
AMI METER (WATER) 0.2 1.0 ES
SPARE SPARE
SPARE
ES1.0
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"2TR" 208/120V 3 4W 10,000 AIC
VOICE DATA CABINET
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
RECEPS (TELECOM 142)1/20 120.90.5
0.10.1
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
1.4
2.7 KVA
7.8 A
0.6
2.8 KVA
0.7
=CALCULATED LOAD:
RECEP (ICS SYSTEM)
- SPARE
12 1/20
0.2 0.2
3/30 SPD
SPARE
RECEP (CCTV SYSTEM)
- 1/20
12 2/20
SPARE
FCU-2
0.10.1 2/20 12 ACCU-2
ACS/ESS CABINET 0.5
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"4UB1" 480/277 3 4W 14,000 AIC
WSHP-2 2/0
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
-1 2
SPARE3/20
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
3/225
PFBPFB
39.3
3.8
SEE ONE LINE DIAGRAM FOR SIZE.
52.7
155.3 KVA
51.3
147.2 KVACALCULATED LOAD:
CWP-6 12 3/30
CWP-8 (BACKUP)
CWP-10 (BACKUP)
SPARE - 3/20
CWP-73/30 12
CWP-9
XFMR "TUB"
SPARE3/20 -
177.1 A
3.8
3.8 3.8
3.8 3.8 0.4
5.4 4.0
4.0
51.3
3/20
3/20
0.4
0.4
-39.3 39.3
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"2UFP" 208/120V 3 4W 10,000 AIC
FACP 12 1/20
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
SPARE0.5
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
SEE ONE LINE DIAGRAM FOR SIZE.
0.7
1.1 KVA
2.2 ACALCULATED LOAD:
0.2 0.2
0.2 0.2
0.2 -
-1/20
SPD3/30
RAPRAP
FIP, TRANSMITTER
FEP
SPARE
FEP
PFB
PFB-
0.8 KVA
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"2GUB" 208/120V 3 4W 10,000 AIC
ENGINE SPACE HEATER 12 1/20
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
BATTERY CHARGER1/20 121.01.0
0.3
-0.7 0.2
0.2 -1.4
-0.6 -0.7
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
4.1
12.5 KVA
33.3 A
4.3
12.0 KVA
4.1
CALCULATED LOAD:
DT-1
PANEL "2UFP"
PANEL "2TR"
3.0 -
SPD
0.2
- PFB
0.2 SPARE
LEAK DETECTION AND FUEL ALARM PANEL
REMOTE ANNUNCIATOR
3.0
ENGINE JACKET WATER HEATER
2/3012
SPARE - -
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"4MDS-UB" 480/277V 3 4W 14,000 AIC
52.7
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
33.9
294.7
1 2
SPARE
PANEL "4UB2"
CH-4
PANEL "4UB1"
ATS "GUB"
51.3 33.9 51.3
13.1 13.3
14.0 98.2
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
297.0
886.6 KVA
743.2 A
294.9
617.9 KVACALCULATED LOAD:
3/100SPARE
PFB
CH-3
3/100 -
33.9
98.2
3/50
98.2 98.2
98.2 98.2
SPD
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"4GUB" 480/277V 3 4W 10,000 AIC
LIGHTING (UTILITY BUILDING) 12 1/20
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
-0.9 -0.1
3.0 3.0
3.0
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
DBP-5
14.0
40.4 KVA
42.0 A
13.3
34.9 KVA
13.1
CALCULATED LOAD:
(EXTERIOR)
SPARE -
1/20 12 SPARE
SPARE
-4.1 -4.3
-4.1
SPDXFMR "TGUB"
DBP-4
DBP-6
12 3/25 3.0
3.0 3.0
3.0 3.0
3.0
3/25 12
3/20 -
CKT
NO. NO.
CKT
PANEL:
LOCATION:
AIC RATING:PHASE:VOLTS: WIRE:
ENCL. TYPE: NEMA AMPERE:MTG:
TOTAL KVA/ :
CONNECTED KVA:
LOAD - KVA
A
BREAKER
LUGS ONLY
REMARKS:
MAINS:DRY
INDOOR OUTDOOR
WET SURF. FLUSH
BRANCH CIRCUIT
DESCRIPTION
NEUTRAL BUS GROUND BUS ISOLATED GROUND BUS NEUTRAL BUS GND. BONDING: YES NO
"4UB2" 480/277V 3 4W 14,000 AIC
ASHP-3 8 3/70
BRANCH CIRCUIT
DESCRIPTION
WIRE
SIZE
WIRE
SIZE
BRK
POLE
BRK
POLE
B C
1 2
ASHP-43/70 8
14.7
0.8
1.3
0.6
SEE ONE LINE DIAGRAM FOR SIZE.
PROVIDE PERMANENT LABEL
INDICATING THE FOLLOWI NG
"POWER SUPPLY ORIGINATES
IN "______"
33.9
101.7 KVA
101.0 KVACALCULATED LOAD:
EF-6
12 3/20HWP-3
HWCP-2
EF-8
SPARE
EF-7
3/20 12 HWP-4
0.3
121.49 A
PFB
SPARE-
0.8
0.8 0.8
0.8 0.8 0.3
0.6 0.6
0.2
0.2 0.2
0.2
0.2 0.2
- PFB-
14.7
14.7 14.7
14.7 14.7
1.3 1.3
0.3 0.3
0.3 0.3
33.9 33.9
HWRP-3
HWRP-4
COORDINATE EXACT LOCATION WITH PLUMBING
DRAWINGS.
ENG
IN
E E R
NA L
P R
OFESS IO
R
MARIANOAB
NE
(ELECTRICAL)
No.1259
ET
ACIFITREC
MAUG
EXP.
V.
April 30,2022
D E P A R T M E N T
O F
T H E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
S Y S T E M S
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .