The file's text, extracted by GovTribe without its formatting.
BY (~FY20)
| N55236-19-R-0003 Section J Attachment S-7 | | | |
| SWRMC PF / CODE | SUPPORT POSITION TITLE | SOW SECTION | LOCATION/BLDG |
| (DEFAULT IS NBSD) | DOL SCA WD CATEGORY | # OF POSITIONS | ST HOURS | |
| (FORMULA) | OT HOURS TOTAL (FORMULA) | CLEARANCE OR BACKGROUND INVESTIGATION | CAC | |
| ("YES" OR "NO") | ON-SITE OR OFF-SITE | | | |
| CONTRACT MANAGEMENT/ADMIN/TRAINING/SAFETY/LOGISTICS | | | | | | | | | | |
| All | Senior Program Manager | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Program Manager | All | Off-Site | N/A | 2 | 3920 | N/A | Tier 3 | Yes | Off-Site |
| All | Administrative/Training Assistant | All | Off-Site | Administrative Assistant | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Financial Technician | All | Off-Site | N/A | 1 | 1960 | N/A | N/A | No | Off-Site |
| All | Environmental/Safety/Health (ESH) Specialist | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
ON-SITE SUPPORT
| Corrosion Control PF 910 | | | | | | | | | | |
| 912 | Powder Coat Lead | 3.3.1 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Powder Coat Technician | 3.3.1 | 123 | Engineering Tech 3 | 9 | 17640 | 225 | N/A | No | On-Site |
| 912 | Welder Lead | 3.3.5 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Welder | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 922 | WTD Technician | 3.3.5 | 123 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 927 | Life Raft Repair Technician | 3.3.4 | 3338 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 929 | RSL Technician | 3.3.6 | 123 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 957 | Painter Lead | 3.3.3 | 3338 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 957 | Painter | 3.3.3 | 3338 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 957 | Electronics Mechanic | 3.3.3 | 3338 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Engine PF 930 | | | | | | | | | | |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 3 | 5 | 9800 | 125 | Tier 3 | Yes | On-Site |
| 913 | AC&R Technician (Habitability) | 3.4.4 | 3418 | HVAC Mechanic | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Lead/Senior Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 4 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 3 | 6 | 11760 | 150 | N/A | No | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 3 | 6 | 11760 | 150 | N/A | No | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 946 | Flex Hose Mechanic | 3.4.3 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Machine PF 940 | | | | | | | | | | |
| 941 | Lead/Senior Inside Machinist | 3.5.2 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 941 | Inside Machinist | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 941 | Inside Machinist | 3.5.4 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-site |
| 942 | Lead/Senior Outside Machinist | 3.5.1 | 61 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | On-Site |
| 942 | Lead/Senior ESU Technician | 3.5.4 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 944 | Deluge Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 928 | SCBA Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 948 | Engraving Technician | 3.5.6 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 949 | Optical Equipment Technician | 3.5.5 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Combat Systems PF 950 | | | | | | | | | | |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 953 | 2M / FO Technician | 3.6.5 | 3338 | Electronics Technician Maint. 2 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 957A | External Communications Technician | 3.6.2 | 3339 | Telecommunications Mechanic 2 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 4 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 2 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 1 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 959 | Lead/Senior Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 5 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 4 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 4 | 6 | 11760 | 150 | Tier 3 | Yes | On-Site |
| Process Improvement 900PI | | | | | | | | | | |
| 900PI | Industrial Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 900PI | Chemical Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Millwright Support | | | | | | | | | | |
| 900 | Millwright | 3.7 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Production Control Div 960 | | | | | | | | | | |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 4 | 23 | 45080 | 575 | Secret | Yes | On-Site |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 3 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3278 | Supply Technician | 12 | 23520 | 300 | Tier 3 | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3279 | Material Coordinator | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Planning 962 | | | | | | | | | | |
| 962 | I-Level Planner | 3.1 | 77 | Engineering Tech 4 | 9 | 17640 | 225 | Secret | Yes | On-Site |
OFF-SITE FACILITY
| Off-Site Hoist Shop | | | | | | | | | | |
| 900 | Lead/Senior Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 4 | 4 | 7840 | 100 | N/A | No | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site |
| Off-Site RIB Shop | | | | | | | | | | |
| 900 | Lead/Senior RIB Technician | 3.11.3 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility | Engineering Tech 4 | 2 | 3920 | 50 | N/A | No | Off-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | Off-Site |
| Off-Site Antenna Preservation Shop | | | | | | | | | | |
| 900 | Lead/Senior Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 4 | 1 | 1960 | 25 | N/A | No | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | Off-Site |
900 Off-Site Facility Admin/Material 3.11.2-3.11.4 Off-Site Facility Supply Technician 1 1960 25 Tier 3 Yes Off-Site
TOTALS: 204 399,840 4,950
BUSINESS SENSITIVE
&"-,Bold"&20&UFollow-On Product Family Support Contract - Level of Effort Table (BASE YEAR)
Page &P of &N
OY1 (~FY21)
| N55236-19-R-0003 Section J Attachment S-7 | | | |
| SWRMC PF / CODE | SUPPORT POSITION TITLE | SOW SECTION | LOCATION/BLDG |
| (DEFAULT IS NBSD) | DOL SCA WD CATEGORY | # OF POSITIONS | ST HOURS | |
| (FORMULA) | OT HOURS TOTAL (FORMULA) | CLEARANCE OR BACKGROUND INVESTIGATION | CAC | |
| ("YES" OR "NO") | ON-SITE OR OFF-SITE | | | |
| CONTRACT MANAGEMENT//ADMIN/TRAINING//ENVIRONMENTAL/SAFETY/HEALTH//LOGISTICS | | | | | | | | | | |
| All | Senior Program Manager | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Program Manager | All | Off-Site | N/A | 2 | 3920 | N/A | Tier 3 | Yes | Off-Site |
| All | Administrative/Training Assistant | All | Off-Site | Administrative Assistant | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Financial Technician | All | Off-Site | N/A | 1 | 1960 | N/A | N/A | No | Off-Site |
| All | Environmental/Safety/Health (ESH) Specialist | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
ON-SITE SUPPORT
| Corrosion Control PF 910 | | | | | | | | | | |
| 912 | Powder Coat Lead | 3.3.1 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Powder Coat Technician | 3.3.1 | 123 | Engineering Tech 3 | 10 | 19600 | 250 | N/A | No | On-Site |
| 912 | Welder Lead | 3.3.5 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Welder | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 922 | WTD Technician | 3.3.5 | 123 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 927 | Life Raft Repair Technician | 3.3.4 | 3338 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 929 | RSL Technician | 3.3.6 | 123 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 949A | RAST/RSD Mechanic | 3.3.2 | 3338 | Engineering Tech 3 | 1 | 1960 | 25 | N/A | No | On-Site |
| 957 | Painter Lead | 3.3.3 | 3338 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 957 | Painter | 3.3.3 | 3338 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 957 | Electronics Mechanic | 3.3.3 | 3338 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Engine PF 930 | | | | | | | | | | |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 3 | 7 | 13720 | 175 | Tier 3 | Yes | On-Site |
| 913 | AC&R Technician (Habitability) | 3.4.4 | 3418 | HVAC Mechanic | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Lead/Senior Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 4 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 3 | 8 | 15680 | 200 | N/A | No | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 4 | 5 | 9800 | 125 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 3 | 8 | 15680 | 200 | N/A | No | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 946 | Flex Hose Mechanic | 3.4.3 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Machine PF 940 | | | | | | | | | | |
| 941 | Lead/Senior Inside Machinist | 3.5.2 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 941 | Inside Machinist | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 941 | Inside Machinist | 3.5.4 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-site |
| 941 | Tools and Parts Attendant | 3.5.4 | 61 | Engineering Tech 2 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 942 | Lead/Senior Outside Machinist | 3.5.1 | 61 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | N/.A | No | On-Site |
| 942 | Lead/Senior ESU Technician | 3.5.4 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 944 | Deluge Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 928 | SCBA Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 948 | Engraving Technician | 3.5.6 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 949 | Optical Equipment Technician | 3.5.5 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Combat Systems PF 950 | | | | | | | | | | |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 953 | 2M / FO Technician | 3.6.5 | 3338 | Electronics Technician Maint. 2 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 957A | External Communications Technician | 3.6.2 | 3339 | Telecommunications Mechanic 2 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 4 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 2 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 1 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 959 | Lead/Senior Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 5 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 4 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 4 | 6 | 11760 | 150 | Tier 3 | Yes | On-Site |
| Process Improvement 900PI | | | | | | | | | | |
| 900PI | Industrial Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 900PI | Chemical Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Millwright Support | | | | | | | | | | |
| 900 | Millwright | 3.7 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Production Control Div 960 | | | | | | | | | | |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 4 | 25 | 49000 | 625 | Secret | Yes | On-Site |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3278 | Supply Technician | 12 | 23520 | 300 | Tier 3 | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3279 | Material Coordinator | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Planning 962 | | | | | | | | | | |
| 962 | I-Level Planner | 3.1 | 77 | Engineering Tech 4 | 10 | 19600 | 250 | Secret | Yes | On-Site |
OFF-SITE FACILITY
| Off-Site Hoist Shop | | | | | | | | | | |
| 900 | Lead/Senior Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 4 | 4 | 7840 | 100 | N/A | No | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | Off-Site |
| RIB Shop (MAY BE OFF-SITE OR ON-SITE FOR OY-1 THROUGH OY-4) | | | | | | | | | | |
| 900 | Lead/Senior RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 4 | 2 | 3920 | 50 | N/A | No | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site/On-Site |
| Off-Site Antenna Preservation Shop | | | | | | | | | | |
| 900 | Lead/Senior Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 4 | 1 | 1960 | 25 | N/A | No | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | Off-Site |
900 Off-Site Facility Admin/Material 3.11.2-3.11.4 Off-Site Facility Supply Technician 1 1960 25 Tier 3 Yes Off-Site
TOTALS: 237 464,520 5,775
&"-,Bold"&20&UContract - Level of Effort Table (OPTION YEAR 1)
Page &P of &N
OY2 (~FY22)
| N55236-19-R-0003 Section J Attachment S-7 | | | |
| SWRMC PF / CODE | SUPPORT POSITION TITLE | SOW SECTION | LOCATION/BLDG |
| (DEFAULT IS NBSD) | DOL SCA WD CATEGORY | # OF POSITIONS | ST HOURS | |
| (FORMULA) | OT HOURS TOTAL (FORMULA) | CLEARANCE OR BACKGROUND INVESTIGATION | CAC | |
| ("YES" OR "NO") | ON-SITE OR OFF-SITE | | | |
| CONTRACT MANAGEMENT//ADMIN/TRAINING//ENVIRONMENTAL/SAFETY/HEALTH//LOGISTICS | | | | | | | | | | |
| All | Senior Program Manager | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Program Manager | All | Off-Site | N/A | 2 | 3920 | N/A | Tier 3 | Yes | Off-Site |
| All | Administrative/Training Assistant | All | Off-Site | Administrative Assistant | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Financial Technician | All | Off-Site | N/A | 1 | 1960 | N/A | N/A | No | Off-Site |
| All | Environmental/Safety/Health (ESH) Specialist | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
ON-SITE SUPPORT
| Corrosion Control PF 910 | | | | | | | | | | |
| 912 | Powder Coat Lead | 3.3.1 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Powder Coat Technician | 3.3.1 | 123 | Engineering Tech 3 | 12 | 23520 | 300 | N/A | No | On-Site |
| 912 | Welder Lead | 3.3.5 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Welder | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 922 | WTD Technician | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 927 | Life Raft Repair Technician | 3.3.4 | 3338 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 929 | RSL Technician | 3.3.6 | 123 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 949A | RAST/RSD Mechanic | 3.3.2 | 3338 | Engineering Tech 3 | 1 | 1960 | 25 | N/A | No | On-Site |
| 957 | Painter Lead | 3.3.3 | 3338 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 957 | Painter | 3.3.3 | 3338 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 957 | Electronics Mechanic | 3.3.3 | 3338 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Engine PF 930 | | | | | | | | | | |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 3 | 8 | 15680 | 200 | Tier 3 | Yes | On-Site |
| 913 | AC&R Technician (Habitability) | 3.4.4 | 3418 | HVAC Mechanic | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Lead/Senior Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 4 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 3 | 9 | 17640 | 225 | N/A | No | On-Site |
| 931 | Lead/Senior Diesel Technician | 3.4.1 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 4 | 6 | 11760 | 150 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 3 | 9 | 17640 | 225 | N/A | No | On-Site |
| 932 | Lead/Senior Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 946 | Flex Hose Mechanic | 3.4.3 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Machine PF 940 | | | | | | | | | | |
| 941 | Lead/Senior Inside Machinist | 3.5.2 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 941 | Inside Machinist | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 941 | Inside Machinist | 3.5.4 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-site |
| 941 | Tools and Parts Attendant | 3.5.4 | 61 | Engineering Tech 2 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 942 | Lead/Senior Outside Machinist | 3.5.1 | 61 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 942 | Lead/Senior ESU Technician | 3.5.4 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 944 | Deluge Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 928 | SCBA Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 3 | 5 | 9800 | 125 | N/A | No | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 948 | Engraving Technician | 3.5.6 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 949 | Optical Equipment Technician | 3.5.5 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Combat Systems PF 950 | | | | | | | | | | |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 3 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 953 | 2M / FO Technician | 3.6.5 | 3338 | Electronics Technician Maint. 2 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 957A | External Communications Technician | 3.6.2 | 3339 | Telecommunications Mechanic 2 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 4 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 3 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 2 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 1 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 959 | Lead/Senior Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 5 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 4 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 4 | 6 | 11760 | 150 | Tier 3 | Yes | On-Site |
| Process Improvement 900PI | | | | | | | | | | |
| 900PI | Industrial Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 900PI | Chemical Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Millwright | | | | | | | | | | |
| 900 | Millwright | 3.7 | 3418 | Engineering Tech 5 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Production Control Div 960 | | | | | | | | | | |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 4 | 27 | 52920 | 675 | Secret | Yes | On-Site |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 3 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3278 | Supply Technician | 13 | 25480 | 325 | Tier 3 | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3279 | Material Coordinator | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Planning 962 | | | | | | | | | | |
| 962 | I-Level Planner | 3.1 | 77 | Engineering Tech 4 | 11 | 21560 | 275 | Secret | Yes | On-Site |
OFF-SITE FACILITY
| Off-Site Hoist Shop | | | | | | | | | | |
| 900 | Lead/Senior Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 4 | 4 | 7840 | 100 | N/A | No | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | Off-Site |
| RIB Shop (MAY BE OFF-SITE OR ON-SITE FOR OY-1 THROUGH OY-4) | | | | | | | | | | |
| 900 | Lead/Senior RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 4 | 3 | 5880 | 75 | N/A | No | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site/On-Site |
| Off-Site Antenna Preservation Shop | | | | | | | | | | |
| 900 | Lead/Senior Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 4 | 1 | 1960 | 25 | N/A | No | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site |
900 Off-Site Facility Admin/Material 3.11.2-3.11.4 Off-Site Facility Supply Technician 1 1960 25 Tier 3 Yes Off-Site
TOTALS: 265 519,400 6,475
&"-,Bold"&20&UContract - Level of Effort Table (OPTION YEAR 2)
Page &P of &N
OY3 (~FY23)
| N55236-19-R-0003 Section J Attachment S-7 | | | |
| SWRMC PF / CODE | SUPPORT POSITION TITLE | SOW SECTION | LOCATION/BLDG |
| (DEFAULT IS NBSD) | DOL SCA WD CATEGORY | # OF POSITIONS | ST HOURS | |
| (FORMULA) | OT HOURS TOTAL (FORMULA) | CLEARANCE OR BACKGROUND INVESTIGATION | CAC | |
| ("YES" OR "NO") | ON-SITE OR OFF-SITE | | | |
| CONTRACT MANAGEMENT//ADMIN/TRAINING//ENVIRONMENTAL/SAFETY/HEALTH//LOGISTICS | | | | | | | | | | |
| All | Senior Program Manager | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Program Manager | All | Off-Site | N/A | 2 | 3920 | N/A | Tier 3 | Yes | Off-Site |
| All | Administrative/Training Assistant | All | Off-Site | Administrative Assistant | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Financial Technician | All | Off-Site | N/A | 1 | 1960 | N/A | N/A | No | Off-Site |
| All | Environmental/Safety/Health (ESH) Specialist | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
ON-SITE SUPPORT
| Corrosion Control PF 910 | | | | | | | | | | |
| 912 | Powder Coat Lead | 3.3.1 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Powder Coat Technician | 3.3.1 | 123 | Engineering Tech 3 | 13 | 25480 | 325 | N/A | No | On-Site |
| 912 | Welder Lead | 3.3.5 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Welder | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 922 | WTD Technician | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 927 | Life Raft Repair Technician | 3.3.4 | 3338 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 929 | RSL Technician | 3.3.6 | 123 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 949A | RAST/RSD Mechanic | 3.3.2 | 3338 | Engineering Tech 3 | 1 | 1960 | 25 | N/A | No | On-Site |
| 957 | Painter Lead | 3.3.3 | 3338 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 957 | Painter | 3.3.3 | 3338 | Engineering Tech 3 | 5 | 9800 | 125 | N/A | No | On-Site |
| 957 | Electronics Mechanic | 3.3.3 | 3338 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Engine PF 930 | | | | | | | | | | |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 3 | 9 | 17640 | 225 | Tier 3 | Yes | On-Site |
| 913 | AC&R Technician (Habitability) | 3.4.4 | 3418 | HVAC Mechanic | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Lead/Senior Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 3 | 9 | 17640 | 225 | N/A | No | On-Site |
| 931 | Lead/Senior Diesel Technician | 3.4.1 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 4 | 6 | 11760 | 150 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 3 | 10 | 19600 | 250 | N/A | No | On-Site |
| 932 | Lead/Senior Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 4 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 946 | Flex Hose Mechanic | 3.4.3 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Machine PF 940 | | | | | | | | | | |
| 941 | Lead/Senior Inside Machinist | 3.5.2 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 941 | Inside Machinist | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 941 | Inside Machinist | 3.5.4 | 61 | Engineering Tech 3 | 4 | 7840 | 100 | Tier 3 | Yes | On-site |
| 941 | Tools and Parts Attendant | 3.5.4 | 61 | Engineering Tech 2 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 942 | Lead/Senior Outside Machinist | 3.5.1 | 61 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 942 | Lead/Senior ESU Technician | 3.5.4 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 944 | Deluge Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 928 | SCBA Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 3 | 5 | 9800 | 125 | N/A | No | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 3 | 5 | 9800 | 125 | N/A | No | On-Site |
| 948 | Engraving Technician | 3.5.6 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 949 | Optical Equipment Technician | 3.5.5 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Combat Systems PF 950 | | | | | | | | | | |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 3 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 953 | 2M / FO Technician | 3.6.5 | 3338 | Electronics Technician Maint. 2 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 957A | External Communications Technician | 3.6.2 | 3339 | Telecommunications Mechanic 2 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 4 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 3 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 2 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 1 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 959 | Lead/Senior Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 5 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 4 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 4 | 6 | 11760 | 150 | Tier 3 | Yes | On-Site |
| Process Improvement 900PI | | | | | | | | | | |
| 900PI | Industrial Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 900PI | Chemical Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Millwright | | | | | | | | | | |
| 900 | Millwright | 3.7 | 3418 | Engineering Tech 5 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Production Control Div 960 | | | | | | | | | | |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 4 | 27 | 52920 | 675 | Secret | Yes | On-Site |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 3 | 5 | 9800 | 125 | Secret | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3278 | Supply Technician | 13 | 25480 | 325 | Tier 3 | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3279 | Material Coordinator | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| Planning 962 | | | | | | | | | | |
| 962 | I-Level Planner | 3.1 | 77 | Engineering Tech 4 | 12 | 23520 | 300 | Secret | Yes | On-Site |
OFF-SITE FACILITY
| Off-Site Hoist Shop | | | | | | | | | | |
| 900 | Lead/Senior Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 4 | 4 | 7840 | 100 | N/A | No | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 3 | 5 | 9800 | 125 | N/A | No | Off-Site |
| RIB Shop (MAY BE OFF-SITE OR ON-SITE FOR OY-1 THROUGH OY-4) | | | | | | | | | | |
| 900 | Lead/Senior RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 4 | 3 | 5880 | 75 | N/A | No | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site/On-Site |
| Off-Site Antenna Preservation Shop | | | | | | | | | | |
| 900 | Lead/Senior Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 4 | 1 | 1960 | 25 | N/A | No | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site |
900 Off-Site Facility Admin/Material 3.11.2-3.11.4 Off-Site Facility Supply Technician 1 1960 25 Tier 3 Yes Off-Site
TOTALS: 281 550,760 6,875
&"-,Bold"&20&UContract - Level of Effort Table (OPTION YEAR 3)
Page &P of &N
OY4 (~FY24)
| N55236-19-R-0003 Section J Attachment S-7 | | | |
| SWRMC PF / CODE | SUPPORT POSITION TITLE | SOW SECTION | LOCATION/BLDG |
| (DEFAULT IS NBSD) | DOL SCA WD CATEGORY | # OF POSITIONS | ST HOURS | |
| (FORMULA) | OT HOURS TOTAL (FORMULA) | CLEARANCE OR BACKGROUND INVESTIGATION | CAC | |
| ("YES" OR "NO") | ON-SITE OR OFF-SITE | | | |
| CONTRACT MANAGEMENT//ADMIN/TRAINING//ENVIRONMENTAL/SAFETY/HEALTH//LOGISTICS | | | | | | | | | | |
| All | Senior Program Manager | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Program Manager | All | Off-Site | N/A | 2 | 3920 | N/A | Tier 3 | Yes | Off-Site |
| All | Administrative/Training Assistant | All | Off-Site | Administrative Assistant | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
| All | Financial Technician | All | Off-Site | N/A | 1 | 1960 | N/A | N/A | No | Off-Site |
| All | Environmental/Safety/Health (ESH) Specialist | All | Off-Site | N/A | 1 | 1960 | N/A | Tier 3 | Yes | Off-Site |
ON-SITE SUPPORT
| Corrosion Control PF 910 | | | | | | | | | | |
| 912 | Powder Coat Lead | 3.3.1 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Powder Coat Technician | 3.3.1 | 123 | Engineering Tech 3 | 14 | 27440 | 350 | N/A | No | On-Site |
| 912 | Welder Lead | 3.3.5 | 123 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 912 | Welder | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | N/A | No | On-Site |
| 922 | WTD Technician | 3.3.5 | 123 | Engineering Tech 3 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 927 | Life Raft Repair Technician | 3.3.4 | 3338 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 929 | RSL Technician | 3.3.6 | 123 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 949A | RAST/RSD Mechanic | 3.3.2 | 3338 | Engineering Tech 3 | 1 | 1960 | 25 | N/A | No | On-Site |
| 957 | Painter Lead | 3.3.3 | 3338 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 957 | Painter | 3.3.3 | 3338 | Engineering Tech 3 | 5 | 9800 | 125 | N/A | No | On-Site |
| 957 | Electronics Mechanic | 3.3.3 | 3338 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Engine PF 930 | | | | | | | | | | |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 911 | Rigger | 3.4.6 | 3418 | Engineering Tech 3 | 10 | 19600 | 250 | Tier 3 | Yes | On-Site |
| 913 | AC&R Technician (Habitability) | 3.4.4 | 3418 | HVAC Mechanic | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Electrician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Lead/Senior Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 913 | Engineering Technician (Habitability) | 3.4.4 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 925 | Welder | 3.4.5 | 3418 | Engineering Tech 3 | 10 | 19600 | 250 | N/A | No | On-Site |
| 931 | Lead/Senior Diesel Technician | 3.4.1 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 4 | 7 | 13720 | 175 | Tier 3 | Yes | On-Site |
| 931 | Diesel Technician | 3.4.1 | 3418 | Engineering Tech 3 | 10 | 19600 | 250 | N/A | No | On-Site |
| 932 | Lead/Senior Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 4 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 932 | Gas Turbine Technician | 3.4.2 | 3418 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 946 | Flex Hose Mechanic | 3.4.3 | 3418 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Machine PF 940 | | | | | | | | | | |
| 941 | Lead/Senior Inside Machinist | 3.5.2 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 941 | Inside Machinist | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 941 | Inside Machinist | 3.5.4 | 61 | Engineering Tech 3 | 4 | 7840 | 100 | Tier 3 | Yes | On-site |
| 941 | Tools and Parts Attendant | 3.5.4 | 61 | Engineering Tech 2 | 1 | 1960 | 25 | Tier 3 | Yes | On-site |
| 942 | Lead/Senior Outside Machinist | 3.5.1 | 61 | Engineering Tech 6 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 4 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 942 | Outside Machinist | 3.5.1 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 942 | Lead/Senior ESU Technician | 3.5.4 | 61 | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Mechanic | 3.5.4 | 61 | Engineering Tech 3 | 2 | 3920 | 50 | N/A | No | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 942 | ESU Electrician | 3.5.4 | 61 | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 944 | Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| 944 | Deluge Valve Technician | 3.5.7 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 928 | SCBA Technician | 3.5.7 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | Compressor Technician | 3.5.3 | 61 | Engineering Tech 3 | 6 | 11760 | 150 | N/A | No | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 945 | AC&R Technician | 3.5.3 | 61 | Engineering Tech 3 | 5 | 9800 | 125 | N/A | No | On-Site |
| 948 | Engraving Technician | 3.5.6 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 949 | Optical Equipment Technician | 3.5.5 | 61 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Combat Systems PF 950 | | | | | | | | | | |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 952 | Gun Systems Technician | 3.6.3 | 3278 | Engineering Tech 3 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 953 | 2M / FO Technician | 3.6.5 | 3338 | Electronics Technician Maint. 2 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 954 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 4 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 955 | Launcher Refurbishment Technician | 3.6.2 | 37 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 957A | External Communications Technician | 3.6.2 | 3339 | Telecommunications Mechanic 2 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 958A | Inside Electrical - Motor Rewind Technician | 3.6.4 | 3278 | Engineering Tech 3 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 985 | Lead/Senior Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 5 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 4 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 958 | Outside Electrical Technician | 3.6.4 | 3278 | Engineering Tech 3 | 3 | 5880 | 75 | Secret | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 2 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| 959B | Metrology Technician | 3.6.6 | NASNI 463 | Metrology Tech 1 | 4 | 7840 | 100 | Tier 3 | Yes | On-Site |
| 959 | Lead/Senior Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 5 | 1 | 1960 | 25 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 4 | 4 | 7840 | 100 | Secret | Yes | On-Site |
| 959 | Interior Communication Technician | 3.6.4 | 3278 | Engineering Tech 3 | 2 | 3920 | 50 | Secret | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 950 | Field/Gauge Cal (Level 1) Technician | 3.6.1 | TBD | Engineering Tech 4 | 6 | 11760 | 150 | Tier 3 | Yes | On-Site |
| Process Improvement 900PI | | | | | | | | | | |
| 900PI | Industrial Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| 900PI | Chemical Engineer | 3.8 | 3418 | Engineering Tech 4 | 1 | 1960 | 25 | Tier 3 | Yes | On-Site |
| Millwright | | | | | | | | | | |
| 900 | Millwright | 3.7 | 3418 | Engineering Tech 5 | 2 | 3920 | 50 | Tier 3 | Yes | On-Site |
| Production Control Div 960 | | | | | | | | | | |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 4 | 27 | 52920 | 675 | Secret | Yes | On-Site |
| 963 | Maintenance Coordinator | 3.9.1 | 3116,77,36,94,3278 | Engineering Tech 3 | 5 | 9800 | 125 | Secret | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3278 | Supply Technician | 13 | 25480 | 325 | Tier 3 | Yes | On-Site |
| 964 | Material Coordinator | 3.9.2 | 3418,61,3339,3279 | Material Coordinator | 3 | 5880 | 75 | Tier 3 | Yes | On-Site |
| Planning 962 | | | | | | | | | | |
| 962 | I-Level Planner | 3.1 | 77 | Engineering Tech 4 | 12 | 23520 | 300 | Secret | Yes | On-Site |
OFF-SITE FACILITY
| Off-Site Hoist Shop | | | | | | | | | | |
| 900 | Lead/Senior Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 4 | 4 | 7840 | 100 | N/A | No | Off-Site |
| 900 | Hoist Technician | 3.11.2 | Off-Site Facility | Engineering Tech 3 | 6 | 11760 | 150 | N/A | No | Off-Site |
| RIB Shop (MAY BE OFF-SITE OR ON-SITE FOR OY-1 THROUGH OY-4) | | | | | | | | | | |
| 900 | Lead/Senior RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 4 | 3 | 5880 | 75 | N/A | No | Off-Site/On-Site |
| 900 | RIB Technician | 3.11.3 | Off-Site Facility or On-Site | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site/On-Site |
| Off-Site Antenna Preservation Shop | | | | | | | | | | |
| 900 | Lead/Senior Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 5 | 1 | 1960 | 25 | Tier 3 | Yes | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 4 | 1 | 1960 | 25 | N/A | No | Off-Site |
| 900 | Antenna Preservation Technician | 3.11.4 | Off-Site Facility | Engineering Tech 3 | 3 | 5880 | 75 | N/A | No | Off-Site |
900 Off-Site Facility Admin/Material 3.11.2-3.11.4 Off-Site Facility Supply Technician 1 1960 25 Tier 3 Yes Off-Site
TOTALS: 290 568,400 7,100
&"-,Bold"&20&UContract - Level of Effort Table (OPTION YEAR 4)
Page &P of &N