Attachment L - VOL4_1363603dwg4of9.pdf
PDF 16 MB Posted
- Attached to
- P475 Aircraft Maintenance Hangar
- Solicitation number
- N4008526R0148
About this file
These architectural drawings detail the design for a multi-level parking garage at Marine Corps Air Station (MCAS) Beaufort in South Carolina, prepared for the Department of the Navy by Naval Facilities Engineering Systems Command. The parking structure is a three-story precast concrete facility with 524 total parking spaces, including standard, ADA, motorcycle, and ramp parking spaces. The design incorporates photovoltaic (PV) panel canopy options, four stairwells, and various technical spaces like electrical and solar inverter rooms. The building features standing seam metal roofing, precast concrete wall panels with different finish textures, and welded wire mesh panel systems on facade sections.
Key technical details include 1-1/2" per foot minimum roof slope, R-25 continuous insulation requirements, and environmental considerations such as an Environmental Severity Classification (ESC) of C4 for building systems and components. The parking garage is designed with multiple access points, guardrails, and specific signage for stairs and rooms. Optional features include a photovoltaic panel system with snow guards and a fence-style snow system at the solar array's lowest edge. The project includes modifications noted in two contract modifications: P00005 from May 2023 and P00006/P00007 from October 2025, suggesting potential phased implementation or design updates.
View the file
Other files
Show 40 more
Latest 50 of 79 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REF. LINE
SEE 00/0-00-000
AE101
A1
AE101
A1
AE101
1 Ref
R e f
1 Ref
R e f
GENERAL SYMBOLS
EXTERIOR ELEVATION
REFERENCE
INTERIOR ELEVATION
REFERENCE
SECTION REFERENCE
REFERENCE FOR DETAIL OR
ENLARGED PLAN
DETAIL / SECTION NUMBER
SHEET NUMBER
LEADER OR NOTATION
EXISTING COLUMN REFERENCE
AND GRID LINES
PARTIAL PLAN REFERENCE LINE
BUILDING LEVEL OR ELEVATION.
ALL BUILDINGS HAVE FIRST
FLOOR SET AT 0'-0". COORDINATE
WITH CIVIL DRAWINGS FOR
FLOOR LEVEL RELATIVE TO SITE
AND EACH OTHER.
REVISION IDENTIFIER
KEY NOTE
CENTERLINE
NEW COLUMN REFERENCE AND
GRID LINES
ROOM NUMBER
ROOM NAME LINE 1
STORAGE
092900.A01 MATERIAL NOTES
INDEPENDENT SUFFIX MATERIAL
OR NOTE SPECIFIER FOR
CONDOC LIST
SPECIFICATION SECTION PREFIX
VAPOR BARRIER (DETAILS)
WORK ABOVE (PLANS)
LATH (DETAILS)
BITUMINOUS DAMPROOFING
(DETAILS)
SPOT ELEVATION RELATED TO
DISTANCE ABOVE FIRST FLOOR
BREAK LINE
N
PLAN
NORTH
PLAN NORTH
TRUE NORTH
A1
AE312
ROOM NAME LINE 2STORAGE
PAE100A1
SHEET SEQUENCE NUMBER
SHEET TYPE
LEVEL 2, DISCIPLINE DESIGNATOR
BUILDING IDENTIFIER PREFIX,
REFER TO BUILDING IDENTIFIER
PREFIX LEGEND
BUILDING IDENTIFIER PREFIX LEGEND
BUILDING 414 M
BUILDING 727 N
OSF / ANNEX O
PARKING GARAGE P
HANGAR -
BUILDING NAME BUILDING PREFIX
MAXIMUM OF 8 CHARACTERS
TYPICAL SHEET NUMBER FORMAT
0/0" = 1'-0"00
VIEW NAME
SMOKE PARTITION (NON-RATED)
1 HOUR FIRE BARRIER
PARTITION LEGEND
NON-RATED PARTITION
SMOKE BARRIER
1.
ARCHITECTURAL SYMBOLS
GLAZING AND LOUVER PREFIXES
W = WINDOW
L = LOUVER
B = BORROWED LITE
S = STOREFRONT
G = GATE
C = CURTAINWALL
T = TRANSLUCENT PANEL
PARTITION TYPE NAMING CONVENTION
ASSEMBLY TYPE
STUD OR CMU SIZE
MODIFIERS
FIRE RATING
A3AC.1
PARTITION SYMBOL ON PLAN
PARTITION TYPE SYMBOL
DOOR NUMBERS:
THE PRIMARY DOOR NUMBER
IS THE ROOM NUMBER. A
DECIMAL IS ADDED TO
DISTINGUISH ADDITIONAL
DOORS IN THE ROOM.
EXISTING PARTITION, DOOR,
FRAME AND HARDWARE TO
BE REMOVED
00 PRECAST WALL PANEL
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
1:
:2
P
M
As indicated
A R
C H
IT
E
C T
U R
A L
A B
B R
E V
IA
T
IO
N
S A
N D
S Y
M B
O
LS
PAE001
EAD RWR BKH
12860308
GENERAL ABBREVIATIONS
# AND SYMBOLS
# NUMBER / POUND
& AND
@ AT
A
A AIR
A/C AIR CONDITIONED
A/E ARCHITECT-ENGINEER
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERE
AO ACCESS OPENING
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
B
BAL BALANCE
BD BOARD
BKOP BACK OF PRECAST / BACK OF PANEL
BLDG BUILDING
BLK BLANK
BM BEAM
BO BOTTOM OF
BOP BOTTOM OF PRECAST
BOS BOTTOM OF STEEL
BRG BEARING
BTUH BRITISH THERMO UNIT / HOUR
C
CCT CUBICLE CURTAIN TRACK
CG CORNER GUARD
CJ CONTROL / CONSTRUCTION JOINT
CL CENTER LINE
CLG CEILING
CLL COLUMN LINE
CLR CLEAR
cm CENTIMETER
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
CO2 CARBON DIOXIDE
CONC CONCRETE
CONT CONTINUED / CONTINUOUS
COORD COORDINATE
CTJ CONTRACTION JOINT
CTR CENTER
D
D DEEP / DEPTH
dBA UNIT OF SOUND
DEG DEGREE
DIA DIAMETER
DIMS DIMENSIONS
DN DOWN
DR DOOR
DWG DRAWING(S)
DWR DRAWER
E
EA EACH
EE EACH END
EJ EXPANSION JOINT
EL ELEVATION
EOS EDGE OF SLAB
EQ EQUAL
ETC ET CETERA
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXIST EXISTING
GENERAL ABBREVIATIONS
F
F FILLER
FAX FACSIMILE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FHC FIRE HOSE CABINET
FIN FINISHED
FLR FLOOR
FO FACE OF
FOS FACE OF SLAB / FACE OF STUD
FT FOOT / FEET
G
G GAS
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEM GLOBAL ELECTRIC MOTORCARS
H
H HIGH
HC HANDICAP
HDWR HARDWARE
HE HORIZONTAL EXIT
HM HOLLOW METAL
HR HOUR
I
IC INTERCOM
ID INSIDE DIAMETER
IN INCH(ES)
INFO INFORMATION
J
JT JOINT
K kPA KILOPASCAL
L
LB POUND
LF LINEAR FEET
LL ANGLE
M m METERS
MAX MAXIMUM
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
mm MILLIMETERS
MO MASONRY OPENING
N
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER
OPH OPPOSITE HAND
OPNG OPENING
P
PL PLATE
PLAM PLASTIC LAMINATE
PR PAIR
PSF POUNDS per SQUARE FOOT
PSI POUNDS per SQUARE INCH
PT PRESSURE TREATED / PAINT
PTS PNEUMATIC TUBE STATION
PV PHOTOVOLTAIC PANEL
GENERAL ABBREVIATIONS
Q
QTR QUARTER
QTY QUANTITY
R
R RISER / RADIUS
RAL FEDERAL COLOR PALETTE
RCP REFLECTED CEILING PLAN
RE RESIDENT ENGINEER
RENO RENOVATE / RENOVATION
REQ REQUIRED
RO ROUGH OPENING
S
S SOUTH / SINK
SEC SECONDARY
SF SQUARE FEET
SIM SIMILAR
SJ SEISMIC JOINT
SPECS SPECIFICATION
SQ SQUARE
SST STAINLESS STEEL
ST STAINED
STC SOUND TRANSMISSION CLASS
STL STEEL
SWGR SWITCHGEAR
T
T TREAD
TEL TELEPHONE
TEMP TEMPERATURE / TEMPORARY
THD THRESHOLD
THK THICKNESS
THRU THROUGH
TLT TOILET
TO TOP OF
TOC TOP OF CONCRETE (CURB)
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PRECAST
TOS TOP OF STEEL
TYP TYPICAL
U
U HEAT TRANSFER COEFFICIENT
U/C/B UNDER COUNTER BASE
UC UNDERCUT
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UR URINAL
V
V VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VTR VENT THRU ROOF
W
W WEST
W WIDTH
W/ WITH
W/O WITHOUT
WD WOOD
WH WALL HUNG / WATER HEATER
WP WATERPROOF / WORKING UNIT
WT WEIGHT
WWF WELDED WIRE FABRIC
M
O D
P
/2
M
O D
P
A N
D P
/2
PAE201
B1
PAE201
D1
PAE201
C1
PAE201
A1
1 2 3 4 5 6 7 9 10
A
B
C
D
B1
PAE301
C1
PAE301
A.2
C.8
UNDEFINED
P102
STAIR 1
PS101
STAIR 4
PS104
STAIR 3
PS103
STAIR 2
PS102
5/8" / 12"
4.8% SLOPE UP1
3 3 3 3
SOLAR INV
P103
ELEC
P104
PAE411
B1
PAE401
A1
PAE401
A3
PAE216
A1
B1
PAE215
B2
A1
PAE413
C1
PAE412
C1
12 @ 9'-0" = 108'-0" 8'-0" 12 @ 9'-0" = 108'-0" 10'-0" 35'-0"
12 @ 9'-0" = 107'-10" 8'-0" 9 @ 9'-0" = 81'-0"
7'-10" 32 @ 9'-0" = 288'-0" 7'-10"
'-6
5' -8
4' -8
'-0
8' -0
8'
-0
8' -0
" 16'-0"
2 @ 8'-0" 8'-0"
16'-0"
2 @ 8'-0" 5'-0"
17'-0"
2 @ 8'-6" 5'-0"
17'-0"
2 @ 8'-6" 5'-0" 9'-0"
18'-0"
2 @ 18'-0" 10'-10" 12 @ 9'-0" 108'-0" 8 @ 4'-6" = 36'-0"
'-0
5'
-0
'-0
'-3
'-0
4' -0
7'
-1 0"
'-0
6' -0
5'
-0
'-8
'-0
5' -0
'-0
'-8
'-0
'-6
'-6
'-0
'-6
'-6
'-0
'-6
6'-2" 10'-4" 10'-4" 6'-2"
A1
PAE301
PAE412
C1
18'-0" 30'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 30'-0" 18'-0"
'-2
'-5
'-1
0"
'-5
'-2
PAE501
A2
16'-6"16'-6"
PAE502
C4
C2
PAE312
A1
PAE311
338'-4"
PS101.2PS101.1 PS104.1
PS103.1PS103.2PS102.2PS102.1
1'
-4
1'-2" 1'-2"
4' -2
4'
-2
P
P
C1
A2
PAE312
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
6'-0"
B2
PAE522
'-0
'-0
PAE502
A2SIM
PAE213
A1
PAE213
A2
TYP
'-1
0" 1'
-6
15'-0" 10'-6" 26'-0"
A6
A1 A1
A6 A6A6 A6
A6 A6
SPKLR
P105
B2
B2 B2
PAE401
B1
A1
B2
6 6 6
OH
A1 ROOM IDENTIFICATION WITH PAPER INSERT
A6 STAIR IDENTIFICATION
B2 EXIT SIGN
INTERIOR SIGN TYPES
*REFER TO VOLUME 2A HANGAR FOR ABA INTERIOR ROOM SIGN TYPES.
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
1:
:3
P
M
As indicated
P A
R K
IN
G
G A
R A
G E
F
LO
O
R P
LA
N
G
R O
U N
D F
LO
O
R
O V
E R
A
LL
PAE101
EAD JAF BKH
12860309
A B
KEYPLAN
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B REFER TO VOLUME 1, SHEETS CS101-CS102, CG101-CG102, AND CG105-CG106 FOR CIVIL
SITE INFORMATION.
C REFER TO VOLUME 1, SHEETS LP101-LP102, LP401, AND LF101 FOR LANDSCAPE AND
LANDSCAPE FURNISHING INFORMATION.
D REFER TO SHEET PGC002 FOR LIFE SAFETY CODE SUMMARY. REFER TO SHEETS
PGC101-PAG121 FOR LIFE SAFETY PLANS.
E REFER TO SHEETS PAG101-PAG121 AND PAG710 FOR PARKING GARAGE SIGNAGE AND
STRIPING INFORMATION AND DETAILS. REFER TO VOLUME 2A HANGAR FOR ABA
INTERIOR ROOM SIGN TYPES.
F PAINT ALL EXPOSED DRAINAGE LINES TO MATCH PRECAST PANELS.
G ARCHITECTURAL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF PRECAST PANEL
OR CMU, UNO.
H REFER TO PAE601 PARKING GARAGE - DOOR SCHEDULE / DOOR/DOOR FRAME,
CURTAINWALL, AND LOUVER ELEVATIONS / DOOR DETAILS FOR (A6) STAIRWAY SIGN
INSTALLATION ELEVATION AND PARKING GARAGE ROOM SIGN MESSAGE SCHEDULE.
I PROVIDE EXTERIOR EXPOSURE CORROSION PROTECTION AND CONTROL IN
ACCORDANCE WITH AN ENVIRONMENTAL SEVERITY CLASSIFICATION (ESC) OF C4 FOR
BUILDING SYSTEMS AND COMPONENTS IN THE FOLLOWING ROOMS: STAIR 1, STAIR 2,
STAIR 3, STAIR 4, P103 SOLAR INV, P104 ELEC, AND P105 SPKLR.
1/16" = 1'-0"A1
FLOOR PLAN - GROUND FLOOR - OVERALL
1 MAIN GROUND FLOOR VEHICLE ENTRY/EXIT.
2 CONCRETE ISLAND. REFER TO A3/PAE401 FOR ENLARGED PLAN. REFER TO VOLUME 1,
SHEET CS101-CS102 AND A4/CS504 FOR ADDITIONAL INFORMATION.
3 WALKWAY TO HANGAR.
4 SHEAR WALL.
5 8' HIGH GALVANIZED CHAIN LINK FENCE WITH 6' DOUBLE SLIDING GATE OPENING, SPACE
POSTS AT 8'-0" OC MAX. REFER TO ADDITIONAL CHAIN-LINK FENCE DETAILS ON PAE553.
6 4" WIDE PAINTED STRIPING. REFER TO SHEET PAG101 FOR ADDITIONAL INFORMATION.
7 DRY STANDPIPE. REFER TO SHEET PFX101 FOR ADDITIONAL INFORMATION. PROVIDE
PIPE GUARDS FOR PIPE PROTECTION PER DETAIL B2/PAE553.
8 SURFACE MOUNTED, REMOVABLE, PEDESTAL BOLLARD, TYP. REFER TO DETAIL
A2/PAE553.
9 FOR STEPS, RAMP AND HANDRAILS, REFER TO VOLUME 1, SHEET CS102 AND LP102 FOR
ADDITIONAL INFORMATION.
10 GUARDRAIL. REFER TO DETAIL D2/PAE421.
11 8" CMU PARTITION. REFER TO SHEET PSF501, DETAIL C2/PSB412, AND DETAIL A1/PAE522
FOR ADDITIONAL INFORMATION.
12 12" LINEAR DRAIN. REFER TO SHEETS PPP101-PPP102 FOR ADDITIONAL INFORMATION.
13 DRAIN FROM ABOVE. PROVIDE STEEL CAGE FOR PIPE PROTECTION PER DETAIL
B2/PAE553.
14 FLOOR DRAIN. REFER TO PPP101A-PPP101B FOR ADDITIONAL INFORMATION.
15 10" DRAIN FROM ABOVE. PROVIDE STEEL CAGE FOR PIPE PROTECTION PER DETAIL
B2/PAE553.
16 3/4" DOWELED EXPANSION JOINT. REFER TO DETAIL C4/PSB412 FOR ADDITIONAL
INFORMATION.
PARKING COUNT
Level Comments Count
GROUND FLR 9'-0" x 18'-6" 104
GROUND FLR 9'-0" x 18'-6" - Ramp 48
GROUND FLR ADA 8'-0" x 18'-6" - 5' Aisle 4
GROUND FLR ADA 8'-0" x 18'-6" - 8' Aisle 2
GROUND FLR ADA 9'-0" x 18'-6 - 11' Aisle 1
GROUND FLR ADA 9'-0" x 18'-6" - 5' Aisle 3
GROUND FLR MC - 4'-6 x 9'-0" 16
GROUND FLR: 178
SECOND FLR 9'-0" x 18'-6" 148
SECOND FLR 9'-0" x 18'-6" - Ramp 48
SECOND FLR: 196
THIRD FLR 9'-0" x 18'-6" 150
THIRD FLR: 150
Grand total: 524
M
O D
P
/2
M
O D
P
A N
D P
/2
PAE201
C1
PAE201
A1
1 2 3 4 5 6 7 9 10
A
B
C
D
B1
PAE301
C1
PAE301
5/8" / 12"
4.8% SLOPE UP
A.2
C.8
STAIR 1
PS201
STAIR 2
PS202 STAIR 3
PS203
STAIR 4
PS204
57621 SF
PARKING
P201
PAE411
B3
PAE216
A1
B1
PAE215
B2
A1
A1
PAE301
PAE412
C3
PAE412
C3
PAE413
C3
4' -1
0"
'-0
'-6
'-6
'-0
'-6
7'-6" 32 @ 9'-0" = 288'-0" 4'-10"
4' -8
'-0
8' -2
'-0
8' -0
'-0
4' -1
0"
7'-6" 126'-0" 9'-0" 32 @ 9'0" = 288'-0" 7'-6"
13'-0" 13'-0"
13'-0" 13'-0"
4' -8
'-0
6' -0
8'
-2
'-0
4' -0
8'
-0
'-0
6' -0
12 @ 9'-0" = 108'-0" 8'-0" 12 @ 9'-0" = 108'-0"
12 @ 9'-0" = 108'-0" 8'-0" 12 @ 9'-0" = 108'-0"
PAE502
A2
C2
PAE312
PAE502
C3
A1
PAE311
18'-0" 30'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 30'-0" 18'-0"
338'-4"
1'-2"
1'
-4
'-2
'-5
'-1
0"
'-5
'-2
4'
-2
4" 1'
-2
1' -2
4"
4' -2
1'-2" 1'-2"
PS203PS202
OPH
C1
A2
PAE312
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
TYP
PAE213
A1
PAE213
A2
PAE501
A2
TYP
A6 A6
A6 A6
055013.B01
A1 ROOM IDENTIFICATION WITH PAPER INSERT
A6 STAIR IDENTIFICATION
B2 EXIT SIGN
INTERIOR SIGN TYPES
*REFER TO VOLUME 2A HANGAR FOR ABA INTERIOR ROOM SIGN TYPES.
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
1:
:3
P
M
As indicated
P A
R K
IN
G
G A
R A
G E
F
LO
O
R P
LA
N
S
E C
O N
D F
LO
O
R
O V
E R
A
LL
PAE102
EAD JAF BKH
12860310
A B
KEYPLAN
1/16" = 1'-0"A1
FLOOR PLAN - SECOND FLOOR - OVERALL
1 SHEAR WALL.
2 4" WIDE PAINTED STRIPING. REFER TO SHEET PAG111 FOR ADDITIONAL INFORMATION.
3 SPRINKLER SYSTEM PIPING FROM BELOW. REFER TO FIRE PROTECTION DRAWINGS
FOR ADDITIONAL INFORMATION.
4 SURFACE MOUNTED, REMOVABLE, PEDESTAL BOLLARD, TYP. REFER TO DETAIL
A2/PAE553.
5 FLOOR DRAIN. REFER TO PPP111A-PPP111B FOR ADDITIONAL INFORMATION.
6 10" DRAIN FROM ABOVE. PROVIDE STEEL CAGE FOR PIPE PROTECTION PER DETAIL
B2/PAE553.
7 CRICKET IN CONCRETE SLAB TO MOVE WATER AROUND OBSTACLE TO FLOW TOWARDS
DRAINS.
8 LINEAR DRAIN. REFER TO PPP111A-PP111B FOR ADDITIONAL INFORMATION.
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B REFER TO VOLUME 1, SHEETS CS101-CS102, CG101-CG102, AND CG105-CG106 FOR CIVIL
SITE INFORMATION.
C REFER TO VOLUME 1, SHEETS LP101-LP102, LP401, AND LF101 FOR LANDSCAPE AND
LANDSCAPE FURNISHING INFORMATION.
D REFER TO SHEET PGC002 FOR LIFE SAFETY CODE SUMMARY. REFER TO SHEETS
PGC101-PAG121 FOR LIFE SAFETY PLANS.
E REFER TO SHEETS PAG101-PAG121 AND PAG710 FOR PARKING GARAGE SIGNAGE AND
STRIPING INFORMATION AND DETAILS. REFER TO VOLUME 2A HANGAR FOR ABA
INTERIOR ROOM SIGN TYPES.
F PAINT ALL EXPOSED DRAINAGE LINES TO MATCH PRECAST PANELS.
G ARCHITECTURAL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF PRECAST PANEL
OR CMU, UNO.
H REFER TO PAE601 PARKING GARAGE - DOOR SCHEDULE / DOOR/DOOR FRAME,
CURTAINWALL, AND LOUVER ELEVATIONS / DOOR DETAILS FOR (A6) STAIRWAY SIGN
INSTALLATION ELEVATION AND PARKING GARAGE ROOM SIGN MESSAGE SCHEDULE.
I PROVIDE EXTERIOR EXPOSURE CORROSION PROTECTION AND CONTROL IN
ACCORDANCE WITH AN ENVIRONMENTAL SEVERITY CLASSIFICATION (ESC) OF C4 FOR
BUILDING SYSTEMS AND COMPONENTS IN THE FOLLOWING ROOMS: STAIR 1, STAIR 2,
STAIR 3, STAIR 4, P103 SOLAR INV, P104 ELEC, AND P105 SPKLR.
PARKING COUNT
Level Comments Count
GROUND FLR 9'-0" x 18'-6" 104
GROUND FLR 9'-0" x 18'-6" - Ramp 48
GROUND FLR ADA 8'-0" x 18'-6" - 5' Aisle 4
GROUND FLR ADA 8'-0" x 18'-6" - 8' Aisle 2
GROUND FLR ADA 9'-0" x 18'-6 - 11' Aisle 1
GROUND FLR ADA 9'-0" x 18'-6" - 5' Aisle 3
GROUND FLR MC - 4'-6 x 9'-0" 16
GROUND FLR: 178
SECOND FLR 9'-0" x 18'-6" 148
SECOND FLR 9'-0" x 18'-6" - Ramp 48
SECOND FLR: 196
THIRD FLR 9'-0" x 18'-6" 150
THIRD FLR: 150
Grand total: 524
M
O D
P
/2
M
O D
P
A N
D P
/2
PAE201
D1
PAE201
C1
PAE201
A1
1 2 3 4 5 6 7 9 10
A
B
C
D
B1
PAE301
C1
PAE301
A.2
C.8
PARKING
P301
STAIR 4
PS304
STAIR 3
PS303
STAIR 2
PS302
STAIR 1
PS301
5/8" / 12"
4.8% SLOPE DOWN
PAE411
A1
PAE216
A1
B1
PAE215
B2
A1
'-6
'-0
'-6
'-6
'-0
6' -0
'-6
'-6
'-0
'-6
3' -1
0"
'-0
'-0
3' -1
0"
13'-0" 13'-0"
13'-0" 13'-0"
7'-6"
32 @ 9'-0" = 288'-0"
7'-6"
7'-6" 32 @ 9'-0" = 288'-0" 7'-6"
18'-6" 27'-4"
12 @ 9'-0" = 108'-0" 11'-6" 12 @ 9'-0" = 108'-0"
12 @ 9'-0" = 108'-0" 11'-6" 12 @ 9'-0" = 108'-0"
3' -1
0"
'-0
'-0
3'
-1 0"
A1
PAE301
PAE412
A1
PAE412
A1
PAE413
A1 A1
PAE311
18'-0" 30'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 30'-0" 18'-0"
338'-4"
1'-2"
4"
10'-4"
4' -2
'-2
'-5
'-1 0"
'-5
'-2
4' -2
1'
-4
1' -2
4"
4" 1'
-2
4" 1'-2"
1'-2" 1'-2"
PS303PS302
PS301 PS304
OPH
C1
A2
PAE312
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
PAE502
A2
TYP
PAE213
A1
PAE213
A2
PAE501
A2TYP
A6
A6 A6
A6
A1 ROOM IDENTIFICATION WITH PAPER INSERT
A6 STAIR IDENTIFICATION
B2 EXIT SIGN
INTERIOR SIGN TYPES
*REFER TO VOLUME 2A HANGAR FOR ABA INTERIOR ROOM SIGN TYPES.
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:5
P
M
As indicated
P A
R K
IN
G
G A
R A
G E
F
LO
O
R P
LA
N
T
H
IR
D F
LO
O
R
O V
E R
A
LL
PAE103
EAD JAF BKH
12860311
A B
KEYPLAN
1/16" = 1'-0"A1
FLOOR PLAN - THIRD FLOOR - OVERALL
1 SHEAR WALL.
2 4" WIDE PAINTED STRIPING. REFER TO SHEET PAG121 FOR ADDITIONAL INFORMATION.
3 DRY STANDPIPE. REFER TO SHEET PFX121 FOR ADDITIONAL INFORMATION. PROVIDE
PIPE GUARDS FOR PIPE PROTECTION PER DETAIL B2/PAE553.
4 SURFACE MOUNTED, REMOVABLE, PEDESTAL BOLLARD, TYP. REFER TO DETAIL
A2/PAE553.
5 CRICKET IN CONCRETE SLAB TO MOVE WATER AROUND OBSTACLE TO FLOW TOWARDS
DRAINS.
6 FLOOR DRAIN. REFER TO PPP121A-PPP121B FOR ADDITIONAL INFORMATION.
7 CONCRETE BASE 16"x24"x36" AT EVERY PV STRUCTURE BASE CENTER BAYS ONLY.
REFER TO STRUCTURAL DRAWINGS FOR FURTHER INFORMATION.
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B REFER TO VOLUME 1, SHEETS CS101-CS102, CG101-CG102, AND CG105-CG106 FOR CIVIL
SITE INFORMATION.
C REFER TO VOLUME 1, SHEETS LP101-LP102, LP401, AND LF101 FOR LANDSCAPE AND
LANDSCAPE FURNISHING INFORMATION.
D REFER TO SHEET PGC002 FOR LIFE SAFETY CODE SUMMARY. REFER TO SHEETS
PGC101-PAG121 FOR LIFE SAFETY PLANS.
E REFER TO SHEETS PAG101-PAG121 AND PAG710 FOR PARKING GARAGE SIGNAGE AND
STRIPING INFORMATION AND DETAILS. REFER TO VOLUME 2A HANGAR FOR ABA
INTERIOR ROOM SIGN TYPES.
F PAINT ALL EXPOSED DRAINAGE LINES TO MATCH PRECAST PANELS.
G ARCHITECTURAL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF PRECAST PANEL
OR CMU, UNO.
H REFER TO PAE601 PARKING GARAGE - DOOR SCHEDULE / DOOR/DOOR FRAME,
CURTAINWALL, AND LOUVER ELEVATIONS / DOOR DETAILS FOR (A6) STAIRWAY SIGN
INSTALLATION ELEVATION AND PARKING GARAGE ROOM SIGN MESSAGE SCHEDULE.
I PROVIDE EXTERIOR EXPOSURE CORROSION PROTECTION AND CONTROL IN
ACCORDANCE WITH AN ENVIRONMENTAL SEVERITY CLASSIFICATION (ESC) OF C4 FOR
BUILDING SYSTEMS AND COMPONENTS IN THE FOLLOWING ROOMS: STAIR 1, STAIR 2,
STAIR 3, STAIR 4, P103 SOLAR INV, P104 ELEC, AND P105 SPKLR.
PARKING COUNT
Level Comments Count
GROUND FLR 9'-0" x 18'-6" 104
GROUND FLR 9'-0" x 18'-6" - Ramp 48
GROUND FLR ADA 8'-0" x 18'-6" - 5' Aisle 4
GROUND FLR ADA 8'-0" x 18'-6" - 8' Aisle 2
GROUND FLR ADA 9'-0" x 18'-6 - 11' Aisle 1
GROUND FLR ADA 9'-0" x 18'-6" - 5' Aisle 3
GROUND FLR MC - 4'-6 x 9'-0" 16
GROUND FLR: 178
SECOND FLR 9'-0" x 18'-6" 148
SECOND FLR 9'-0" x 18'-6" - Ramp 48
SECOND FLR: 196
THIRD FLR 9'-0" x 18'-6" 150
THIRD FLR: 150
Grand total: 524
M
O D
P
/2
M
O D
P
A N
D P
/2
PAE201
D1
PAE201
C1
PAE201
A1
1 2 3 4 5 6 7 9 10
A
B
C
D
B1
PAE301
C1
PAE301
A.2
C.8
A1
PAE301
PAE401
B2
034533.A04
302'-4"
PAE402
A2
PAE402
C3
A1
PAE311
TYP
PAE412
A3
PAE413
A3
076115.A01
076115.A01
076115.A01
076115.A01
/2
/2
/2
/2
PAE411
A3
OPH PAE412
A3
C3
PAE521
5'-1" 23'-5"
TYP. BEAM SPACING
27'-0"
TYP. BEAM SPACING
27'-0" 18'-9" 9'-9"
6'-3"
TYP. BEAM SPACING
27'-0"
TYP. BEAM SPACING
27'-0" 6'-3"
6'-3"
TYP. BEAM SPACING
27'-0"
TYP. BEAM SPACING
27'-0" 6'-3"
5'-3" .
TYP. BEAM SPACING
27'-0"
TYP. BEAM SPACING
27'-0" 18'-9" 9'-9"
PV CANOPY SYSTEM
297'-1"
P V
C A
N O
P Y
S Y
S T
E M
'-9
PV CANOPY SYSTEM
234'-8 3/4"
P V
C A
N O
P Y
S Y
S T
E M
PV CANOPY SYSTEM
234'-10"
P V
C A
N O
P Y
S Y
S T
E M
'-9
PV CANOPY SYSTEM
296'-9 3/4"
C A
N O
P Y
P V
S Y
S T
E M
'-9
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
S
LO
P E
A1
PAE582
5 6
5 6
5 6
5 6
23'-5"
*BASE BID / BID OPTION NOTE:
IF REFERENCED OPTIONS ARE NOT SELECTED,
REFER TO VOLUME 6 DRAWINGS FOR BASE BID ONLY
INFORMATION.
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:5
P
M
As indicated
P A
R K
IN
G
G A
R A
G E
R
O O
F P
LA
N
O
V E
R A
LL
PAE104
EAD JAF BKH
12860312
1/16" = 1'-0" A1
ROOF PLAN
A B
KEYPLAN
1 VIEW ON SHEET DOES NOT INCLUDE ROOF.
2 ALUMINUM CANOPY SYSTEM WITH INTEGRAL DRAINAGE FOR PHOTOVOLTAIC PANEL.
PROVIDE IF PARKING GARAGE PV PANEL OPTION IS AWARDED. REFER TO DETAIL
A1/PAE582. REFER TO ELECTRICAL DRAWINGS PEP103A-PEP103B FOR PHOTOVOLTAIC
PANEL SYSTEM INFORMATION.
3 ALUMINUM CANOPY SYSTEM WITH INTEGRAL DRAINAGE FOR PHOTOVOLTAIC PANEL.
PROVIDE IF PARKING GARAGE PV PANEL OPTION IS AWARDED. REFER TO DETAIL
A3/PAE582. REFER TO ELECTRICAL DRAWINGS PEP103A-PEP103B FOR PHOTOVOLTAIC
PANEL SYSTEM INFORMATION.
4 PHOTOVOLTAIC PANEL SYSTEM. PROVIDE IF PARKING GARAGE PV PANEL OPTION IS
AWARDED. REFER TO SHEET PEP103 FOR ADDITIONAL INFORMATION.
5 PAD-STYLE SNOW GUARD, 6" WIDE, 2 PER PANEL, IMPLEMENTED BETWEEN PV PANELS
IN THE HORIZONTAL JOINT UPSLOPE IN THE ARRAY.
6 FENCE-STYLE SNOW SYSTEM, 2" HIGH, INSTALLED AT THE LOWEST EDGE OF THE
SOLAR ARRAY.
MATERIAL NOTES
034533.A04 PRECAST/PRESTRESSED CONCRETE WALL PANEL
076115.A01 STANDING-SEAM METAL ROOF PANEL
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B ARCHITECTURAL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF PRECAST PANEL
OR CMU, UNO.
C FOR ALL ROOF INSULATION, PROVIDE AN R-VALUE EQUAL TO R-25 MINIMUM
CONTINUOUS INSULATION. INSULATION FOR DESIGN PURPOSES IS BASED ON 1"
POLYISOCYANURATE INSULATION = R-6.
D SLOPED ROOF COMPOSITION IS AN ALUMINUM STANDING SEAM METAL ROOFING PANEL
ON 5/8" GLASS MAT COVER BOARD OVER AND BELOW THE 4" POLYISOCYANURATE RIGID
BOARD INSULATION ON METAL DECK. REFER TO SPECIFICATION SECTION 07 61 15.
REFER TO STRUCTURAL DRAWINGS FOR DECK INFORMATION.
E REFER TO SHEETS PAE582 FOR PV SUPPORT STRUCTURE DETAILS AND PEP103 FOR PV
PANEL INFORMATION.
F ARROWS INDICATE ROOF SLOPE. PROVIDE 1-1/2" PER FOOT MINIMUM SLOPE AT
STANDING SEAM METAL ROOF.
G PROVIDE EXTERIOR EXPOSURE CORROSION PROTECTION AND CONTROL IN
ACCORDANCE WITH AN ENVIRONMENTAL SEVERITY CLASSIFICATION (ESC) OF C4 FOR
BUILDING SYSTEMS AND COMPONENTS IN THE FOLLOWING ROOMS: STAIR 1, STAIR 2,
STAIR 3, STAIR 4, AND PV CANOPY.
M
O D
P
/2
M
O D
P
A N
D P
/2
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
1234567910
C1
PAE3018
A1
PAE311
034533.A04
034533.A04034533.A04 034533.A03034533.A04 034533.A04
084400.A01
034533.A04034533.A04
034533.A04
5 5 5 5 5 5
5 5 5 5 5 5
076115.A01
076115.A01
034533.A04
034533.A03
034533.A04 076115.A01 076115.A01
034533.A04034533.A03
PAE212
B1
PAE212
A1
034533.A02
055200.R01
PM-1PM-1
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
ABCD B1
PAE301
A.2C.8
A1
PAE301
034533.A04
034533.A04
034533.A04 055200.R01034533.A03
055013.A04
034533.A04
084400.A01
076115.A01
089100.A01
034533.A04
084400.A01
076115.A01
076115.A01
089100.A015
034533.A04
PAE213
C1
PAE213
A3
034533.A02 1 1/2" / 1'-0" 1 1/2" / 1'-0"
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
1 2 3 4 5 6 7 9 10
C1
PAE301 81
055200.R01
084400.A01
034533.A04
034533.A04
034533.A03 034533.A04
034533.A041 1 1 1 1
5 5
5 5
5 5
084400.A01
076115.A01
076115.A01
034533.A03 5
034533.A04 034533.A03
055200.R01 034533.A03
034533.A04
084400.A01 076115.A01
076115.A01
084400.A01
034533.A04034533.A03 034533.A04
PAE214
C1
PAE214
A1
055913.M13 1 1 1 1
1 2
PM-1
PM-1
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
A B C D B1
PAE301
A.2 C.8
1 1
A1
PAE301
034533.A03
034533.A04034533.A04
034533.A04
034533.A04
055013.A04
5 5
5 5
034533.A04
076115.A01
076115.A01
084400.A01
089100.A01
6081113.A01 081113.A01
089100.A01
034533.A04
084400.A01
076115.A01 076115.A01
PAE211
C1
PAE211
A3
034533.A02
055913.M13
1 1/2" / 1'-0" 1 1/2" / 1'-0"
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:5
P
M
1/16" = 1'-0"
P A
R K
IN
G
G A
R A
G E
B
U
IL
D
IN
G E
LE
V
A T
IO
N
S
PAE201
EAD JAF BKH
12860313
1/16" = 1'-0" B1
NORTH ELEVATION
1/16" = 1'-0" D1
EAST ELEVATION
1/16" = 1'-0" A1
SOUTH ELEVATION
1/16" = 1'-0" C1
WEST ELEVATION
1 WELDED WIRE PANEL PLANT SYSTEM, CENTER BETWEEN COLUMNS. REFER TO DETAIL
C2/PAE552 AND SHEET PAE552 FOR SECTION DETAIL.
2 WELDED WIRE PANEL PLANT SYSTEM, CENTER BETWEEN COLUMNS. REFER TO DETAIL
A3/PAE552 AND SHEET PAE552 FOR SECTION DETAIL.
3 SCREEN / VISION BARRIER WITH SIGNAGE LETTERS. REFER TO A2/PAE551 FOR EAST
ENTRANCE SCREEN ELEVATION AND PAE551 FOR TYPICAL SECTION AND DETAILS.
4 SCREEN / VISION BARRIER WITH SIGNAGE LETTERS. REFER TO C2/PAE551 FOR EAST
ENTRANCE SCREEN ELEVATION AND PAE551 FOR TYPICAL SECTION AND DETAILS.
5 OPEN.
6 TYPICAL LIGHT FIXTURE. REFER TO PEL101-PEL103 FOR ADDITIONAL INFORMATION.
8 ALUMINUM STEEL CANOPY SYSTEM WITH INTEGRAL DRAINAGE FOR PHOTOVOLTAIC
PANEL. PROVIDE IF PARKING GARAGE PV PANEL OPTION IS AWARDED. REFER TO
DETAIL A3/PAE582. REFER TO ELECTRICAL DRAWINGS PEP103A-PEP103B FOR
PHOTOVOLTAIC PANEL SYSTEM INFORMATION.
9 STANDING SEAM METAL ROOF PANEL IN VERTICAL APPLICATION.
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".
REFER TO VOLUME 1, SHEETS CG101-CG102 FOR SLAB ELEVATIONS RELATIVE TO
NORTH AMERICAN VERTICAL DATUM (NAVD) SYSTEM.
C PROVIDE 1-1/2" PER FOOT MINIMUM SLOPE AT STANDING SEAM METAL ROOF.
D REFER TO SHEETS PAE211-PAE216 FOR ENLARGED ELEVATIONS AND PAE221-PAE229
FOR PRECAST PANEL ELEVATIONS.
E REFER TO SHEETS PAG101-PAG221 AND PAG701-PAG707 FOR SIGNAGE LOCATIONS AND
ELEVATIONS.
G REFER TO SHEET PAE104Z FOR PLAN WITHOUT THE PHOTOVOLTAIC (PV) OPTION.
MATERIAL NOTES
034533.A02 PRECAST/PRESTRESSED CONCRETE BEAM
034533.A03 PRECAST/PRESTRESSED CONCRETE COLUMN
034533.A04 PRECAST/PRESTRESSED CONCRETE WALL PANEL
055013.A04 EXTRUDED ALUMINUM TUBE
055200.R01 STEEL GUARDRAIL
055913.M13 EXTERIOR TRELLIS
076115.A01 STANDING-SEAM METAL ROOF PANEL
081113.A01 STEEL DOOR
084400.A01 GLAZED ALUMINUM CURTAIN WALL ASSEMBLY
089100.A01 EXTRUDED ALUMINUM WALL LOUVER
PAE101, PAE102, PAE103, PAE104
PAE101, PAE102, PAE103, PAE104
PAE101, PAE102, PAE103, PAE104
PAE101, PAE102, PAE103, PAE104
M
O D
P
/2
M
O D
P
A N
D P
/2
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
A B C
B1
PAE301
A.2
320 321
315315
034533.A03
034533.A04
034533.A04
034533.A03
034533.A04
034533.A03
2' -3
O
PE
N
3' -0
7'
-0
O
PE
N
5' -0
6'
-6
O
PE
N
5' -0
3'
-6
61'-6"
055913.M13
084400.A01
076115.A01
076115.A01
089100.A01
081113.A01
076115.U02 076115.U01
034533.A04
055013.B01 033000.A08
2' -3
O P
E N
3' -0
7'
-0
O P
E N
5' -0
6'
-6
C
LR
O P
E N
IN
G
9' -6
CLEAR OPENING
49'-4 1/4"
034533.A04
PAE551
A2
034533.A02
'-1
0"
A2
PAE521
MP-1
MP-1
AF-1, IG-1
PC-1
PC-1
HM-1
PC-2
HM-1
PC-1PC-1
PM-1
PM-1
1 1/2" / 1'-0"
PC-3 PC-3 PC-3 PC-3
32'-3"
TO CONC
BEAM
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
C DC.8
A1
PAE301
320.1321.1
034533.A03
034533.A03
3' -6
O
PE
N
5' -0
6'
-6
O
PE
N
5' -0
7'
-0
O
PE
N
3' -0
2'
-3
084400.A01
076115.A01
076115.A01
089100.A01
076115.U02
076115.U01
081113.A01
034533.A04
034533.A04
034533.A04
055013.A04
055913.M13
034533.A02
'-1
0"
A2
PAE521
PM-1
PM-1
HM-1
MP-1
MP-1
AF-1, IG-1
PC-1
PC-1
PC-2
HM-1
PM-1
1 1/2" / 1'-0"
PC-3PC-3
32'-3"
TO CONC
BEAM
EXTERIOR FINISH LEGEND
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST MEDIUM - PCI 110
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 141
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 110
ADDITIONAL FINISHES:
PM-1 PREFINISHED METAL
KINGSPAN SLR DARK BRONZE
PC-3
PC-2
PC-1
AF-1 CURTAINWALL / ALUMINUM WINDOW FRAME /
ALUMINUM DOOR FRAME
KINGSPAN SLR DARK BRONZE
HM-1 HM DOOR / HM DOOR FRAME / LOUVER /
LOUVER FRAME
SW 6072 VERSATILE GRAY
INSULATED LAMINATED VISION GLASS
VITRO SOLARBRONZE
IG-1
STANDING SEAM METAL PANEL
KINGSPAN SLR DARK BRONZE
MP-1
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:0
P
M
1/8" = 1'-0"
P A
R K
IN
G
G A
R A
G E
E
N
LA
R G
E D
E
LE
V A
T
IO
N S
PAE211
EAD JAF BKH
12860314
1/8" = 1'-0"C1
PARTIAL ELEVATION - WEST
1/8" = 1'-0" A3
PARTIAL ELEVATION - WEST
MATERIAL NOTES
033000.A08 CONCRETE CURB
034533.A02 PRECAST/PRESTRESSED CONCRETE BEAM
034533.A03 PRECAST/PRESTRESSED CONCRETE COLUMN
034533.A04 PRECAST/PRESTRESSED CONCRETE WALL PANEL
055013.A04 EXTRUDED ALUMINUM TUBE
055013.B01 STEEL BOLLARD
055913.M13 EXTERIOR TRELLIS
076115.A01 STANDING-SEAM METAL ROOF PANEL
076115.U01 GUTTER
076115.U02 DOWNSPOUT
081113.A01 STEEL DOOR
084400.A01 GLAZED ALUMINUM CURTAIN WALL ASSEMBLY
089100.A01 EXTRUDED ALUMINUM WALL LOUVER
1 WELDED WIRE PANEL PLANT SYSTEM, CENTER BETWEEN COLUMNS. REFER TO SHEET
PAE552 FOR ADDITIONAL INFORMATION.
2 PRECAST GRADE SPANDREL.
3 SCREEN / VISION BARRIER WITH SIGNAGE LETTERS. REFER TO SHEET PAE551 FOR
ADDITIONAL INFORMATION.
4 STANDING SEAM METAL ROOF PANEL IN VERTICAL APPLICATION.
5 LIGHT FIXTURE. REFER TO SHEETS PEL101 FOR ADDITIONAL INFORMATION.
PAE201
PAE201
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".
REFER TO VOLUME 1, SHEETS CG101-CG102 FOR SLAB ELEVATIONS RELATIVE TO NORTH
AMERICAN VERTICAL DATUM (NAVD) SYSTEM.
C WHERE COLOR IS SHOWN AS BEING SPECIFIC TO ONE MANUFACTURER, AN EQUIVALENT
COLOR BY ANOTHER MANUFACTURER MAY BE SUBMITTED FOR APPROVAL.
MANUFACTURERS AND MATERIALS SPECIFIED ARE NOT INTENDED TO LIMIT THE
SELECTION OF EQUAL COLORS FROM OTHER MANUFACTURERS.
D PROVIDE 1-1/2" PER FOOT MINIMUM SLOPE AT STANDING SEAM METAL ROOF.
E REFER TO SHEETS PAE221-PAE229 FOR PRECAST PANEL ELEVATIONS.
F REFER TO SHEETS PAG101-PAG221 AND PAG701-PAG707 FOR SIGNAGE LOCATIONS AND
ELEVATIONS.
G REFER TO SHEET PAE104Z FOR PLAN WITHOUT THE PHOTOVOLTAIC (PV) OPTION.
M
O D
P
/2
M
O D
P
A N
D P
/2
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
67910 8
034533.A03
2 2
2 2
3' -6
'-6
'-6
3' -6
O
PE
N
5' -0
'-6
O
PE
N
3' -0
076115.A01076115.A01
084400.A01
034533.A04
084400.A01
034533.A04
034533.A04
034533.A03 034533.A03 055200.R01
055200.R01
055200.R01
034533.A02
034533.A02
PC-1
HM-1
HM-1
HM-1
AF-1, IG-1
PC-2
MP-1MP-1
AF-1, IG-1
PM-1
PC-1 034533.A04
PC-2
PC-3
3' -6
O
PE
N
5' -0
'-6
O
PE
N
3' -0
2'
-3
OPEN
5'-8" 23'-2"
PC-3
034533.A03
PC-3PC-3
034533.A03
PC-3
034533.A04
PC-1
1 PM-1
32'-3"
TO CONC
PC-3
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
12345
C1
PAE301
034533.A04
3' -6
O
PE
N
5' -0
'-6
O
PE
N
3' -0
2'
-3
A1
PAE311
084400.A01
034533.A04 076115.A01
076115.A01
034533.A03
084400.A01
034533.A03
055013.B01
034533.A04
034533.A03
034533.A04
034533.A03
034533.A04
055200.R01
333 334 335 336
11'-8" 7'-6" 16'-9"
OPEN
5'-4" 16'-8"
OPEN
5'-4" 3'-11" 12'-10"
OPEN
5'-4" 15'-8"
OPEN
8'-4" 5'-10" 15'-1"034533.A04
PC-1 PC-1
PC-2
PM-1
PC-1
034533.A04
PC-2
PC-2
MP-1
MP-1
PC-1
AF-1, IG-1
AF-1, IG-1
HM-1
PC-3
3' -6
O
PE
N
5' -0
'-6
O
PE
N
3' -0
2'
-3
PC-3PC-3
034533.A04
PC-1
034533.A04
034533.A04
PC-1
PC-1
034533.A04
PC-2
PC-3
034533.A03
PC-3
034533.A03
PC-3
1 PM-1
3' -6
'-6
'-6
5'
-9
32'-3"
TO CONC
3' -6
O
PE
N
5' -0
'-6
O
PE
N
3' -0
2'
-3
EXTERIOR FINISH LEGEND
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST MEDIUM - PCI 110
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 141
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 110
ADDITIONAL FINISHES:
PM-1 PREFINISHED METAL
KINGSPAN SLR DARK BRONZE
PC-3
PC-2
PC-1
AF-1 CURTAINWALL / ALUMINUM WINDOW FRAME /
ALUMINUM DOOR FRAME
KINGSPAN SLR DARK BRONZE
HM-1 HM DOOR / HM DOOR FRAME / LOUVER /
LOUVER FRAME
SW 6072 VERSATILE GRAY
INSULATED LAMINATED VISION GLASS
VITRO SOLARBRONZE
IG-1
STANDING SEAM METAL PANEL
KINGSPAN SLR DARK BRONZE
MP-1
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:0
P
M
1/8" = 1'-0"
P A
R K
IN
G
G A
R A
G E
E
N
LA
R G
E D
E
LE
V A
T
IO
N S
PAE212
EAD JAF BKH
12860315
1/8" = 1'-0" B1
PARTIAL ELEVATION - NORTH
1/8" = 1'-0" A1
PARTIAL ELEVATION - NORTH
MATERIAL NOTES
034533.A02 PRECAST/PRESTRESSED CONCRETE BEAM
034533.A03 PRECAST/PRESTRESSED CONCRETE COLUMN
034533.A04 PRECAST/PRESTRESSED CONCRETE WALL PANEL
055013.B01 STEEL BOLLARD
055200.R01 STEEL GUARDRAIL
076115.A01 STANDING-SEAM METAL ROOF PANEL
084400.A01 GLAZED ALUMINUM CURTAIN WALL ASSEMBLY
1 ALUMINUM CANOPY SYSTEM WITH INTEGRAL DRAINAGE FOR PHOTOVOLTAIC PANEL.
PROVIDE IF PARKING GARAGE PV PANEL OPTION IS AWARDED. REFER TO DETAIL
A3/PAE582. REFER TO ELECTRICAL DRAWINGS PEP103A-PEP103B FOR
PHOTOVOLTAIC PANEL SYSTEM INFORMATION.
2 PRECAST GRADE SPANDREL.
3 OPEN.
4 STANDING SEAM METAL ROOF PANEL IN VERTICAL APPLICATION.
PAE211
PAE201
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".
REFER TO VOLUME 1, SHEETS CG101-CG102 FOR SLAB ELEVATIONS RELATIVE TO NORTH
AMERICAN VERTICAL DATUM (NAVD) SYSTEM.
C WHERE COLOR IS SHOWN AS BEING SPECIFIC TO ONE MANUFACTURER, AN EQUIVALENT
COLOR BY ANOTHER MANUFACTURER MAY BE SUBMITTED FOR APPROVAL.
MANUFACTURERS AND MATERIALS SPECIFIED ARE NOT INTENDED TO LIMIT THE
SELECTION OF EQUAL COLORS FROM OTHER MANUFACTURERS.
D PROVIDE 1-1/2" PER FOOT MINIMUM SLOPE AT STANDING SEAM METAL ROOF.
E REFER TO SHEETS PAE221-PAE229 FOR PRECAST PANEL ELEVATIONS.
F REFER TO SHEETS PAG101-PAG221 AND PAG701-PAG707 FOR SIGNAGE LOCATIONS AND
ELEVATIONS.
G REFER TO SHEET PAE104Z FOR PLAN WITHOUT THE PHOTOVOLTAIC (PV) OPTION.
KEY NOTES 00
M
O D
P
/2
M
O D
P
A N
D P
/2
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
BCD
B1
PAE301
C.8
A1
PAE301
320.3 321.3
034533.A03
034533.A04
034533.A03
034533.A04
2 2
O
PE
N
3' -0
7'
-0
O
PE
N
5' -0
6'
-6
O
PE
N
5' -0
3'
-6
084400.A01
076115.A01
076115.A01
034533.A04
076115.U02
076115.U01
081113.A01
089100.A01
034533.A04
034533.A03
034533.A04
034533.A03
034533.A02
055013.A04
034533.A04
MP-1
MP-1
AF-1, IG-1
PC-1
HM-1
PC-2
HM-1
PC-1
PC-1 PC-1
PC-1
PM-1
PM-1
PM-1
PC-3
PC-3
1 1/2" / 1'-0"
PC-3
O
PE
N
3' -0
7'
-0
O
PE
N
5' -0
6'
-6
O
PE
N
5' -0
3'
-6
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
AB A.2
320.1322
034533.A03
034533.A04 034533.A03
4'-2" 29'-0" 6'-11"
7' -0
5'
-0
6' -6
5'
-0
3' -6
055013.B01 033000.A08
076115.U02
076115.U01
089100.A01
034533.A04
084400.A01
076115.A01
076115.A01
034533.A04
034533.A04
1.5
089100.A01
034533.A04
PAE551
C2
055200.R01
055200.R01
034533.A02
PM-1
PM-1
PC-2
HM-1
HM-1
HM-1
PC-1
PC-1
HM-1
PC-1
AF-1, IG-1
MP-1
MP-1
EXTERIOR FINISH LEGEND
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST MEDIUM - PCI 110
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 141
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 110
ADDITIONAL FINISHES:
PM-1 PREFINISHED METAL
KINGSPAN SLR DARK BRONZE
PC-3
PC-2
PC-1
AF-1 CURTAINWALL / ALUMINUM WINDOW FRAME /
ALUMINUM DOOR FRAME
KINGSPAN SLR DARK BRONZE
HM-1 HM DOOR / HM DOOR FRAME / LOUVER /
LOUVER FRAME
SW 6072 VERSATILE GRAY
INSULATED LAMINATED VISION GLASS
VITRO SOLARBRONZE
IG-1
STANDING SEAM METAL PANEL
KINGSPAN SLR DARK BRONZE
MP-1
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
DC.8
076115.A01
076115.A01
084400.A01
034533.A02
034533.A03
034533.A04
034533.A04
081113.A01
081113.A01
081113.A01
076115.U01
1.5
323.3 320.4
034533.A04
034533.A03
PM-1
PC-1
HM-1
HM-1
HM-1
MP-1
MP-1
AF-1, IG-1
1 PM-1
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
076115.A01
076115.U01
076115.A01
034533.A04
055013.B01
055013.B01
055013.B01
076115.U02
325.3
MP-1
PM-1
MP-1
PC-1
034533.A07
034533.A07
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:0
P
M
1/8" = 1'-0"
P A
R K
IN
G
G A
R A
G E
E
N
LA
R G
E D
E
LE
V A
T
IO
N S
PAE213
EAD JAF BKH
12860316
1/8" = 1'-0"C1
PARTIAL ELEVATION - EAST
1/8" = 1'-0"A3
PARTIAL ELEVATION - EAST
MATERIAL NOTES
033000.A08 CONCRETE CURB
034533.A02 PRECAST/PRESTRESSED CONCRETE BEAM
034533.A03 PRECAST/PRESTRESSED CONCRETE COLUMN
034533.A04 PRECAST/PRESTRESSED CONCRETE WALL PANEL
034533.A07 PRECAST/PRESTRESSED CONCRETE FLOOR DOUBLE TEE
055013.A04 EXTRUDED ALUMINUM TUBE
055013.B01 STEEL BOLLARD
055200.R01 STEEL GUARDRAIL
076115.A01 STANDING-SEAM METAL ROOF PANEL
076115.U01 GUTTER
076115.U02 DOWNSPOUT
081113.A01 STEEL DOOR
084400.A01 GLAZED ALUMINUM CURTAIN WALL ASSEMBLY
089100.A01 EXTRUDED ALUMINUM WALL LOUVER
1 ALUMINUM CANOPY SYSTEM WITH INTEGRAL DRAINAGE FOR PHOTOVOLTAIC PANEL.
PROVIDE IF PARKING GARAGE PV PANEL OPTION IS AWARDED. REFER TO DETAIL
A3/PAE582. REFER TO ELECTRICAL DRAWINGS PEP103A-PEP103B FOR PHOTOVOLTAIC
PANEL SYSTEM INFORMATION.
2 PRECAST GRADE SPANDREL.
3 OPEN.
4 FIRE DEPARTMENT CONNECTION. REFER TO SHEETS PFX101 FOR ADDITIONAL
INFORMATION.
5 LIGHT FIXTURE. REFER TO SHEETS PEL101 FOR ADDITIONAL INFORMATION.
6 SURFACE MOUNTED, REMOVABLE, PEDESTAL BOLLARD, TYP. REFER TO DETAIL
A2/PAE553.
7 FOR STEPS, RAMP AND HANDRAILS, REFER TO VOLUME 1, SHEET CS102 AND LP102 FOR
ADDITIONAL INFORMATION.
8 EXTERIOR BUILDING NUMBER. REFER TO VOLUME 2A, SHEET AG101 FOR ADDITIONAL
INFORMATION.
9 STANDING SEAM METAL ROOF PANEL IN VERTICAL APPLICATION.
1/8" = 1'-0"A1
PARTIAL ELEVATION - WEST STAIR 3
1/8" = 1'-0"A2
PARTIAL ELEVATION
PAE101, PAE102, PAE103 PAE101, PAE102, PAE103
PAE201
PAE201
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".
REFER TO VOLUME 1, SHEETS CG101-CG102 FOR SLAB ELEVATIONS RELATIVE TO NORTH
AMERICAN VERTICAL DATUM (NAVD) SYSTEM.
C WHERE COLOR IS SHOWN AS BEING SPECIFIC TO ONE MANUFACTURER, AN EQUIVALENT
COLOR BY ANOTHER MANUFACTURER MAY BE SUBMITTED FOR APPROVAL.
MANUFACTURERS AND MATERIALS SPECIFIED ARE NOT INTENDED TO LIMIT THE
SELECTION OF EQUAL COLORS FROM OTHER MANUFACTURERS.
D PROVIDE 1-1/2" PER FOOT MINIMUM SLOPE AT STANDING SEAM METAL ROOF.
E REFER TO SHEETS PAE221-PAE229 FOR PRECAST PANEL ELEVATIONS.
F REFER TO SHEETS PAG101-PAG221 AND PAG701-PAG707 FOR SIGNAGE LOCATIONS AND
ELEVATIONS.
G REFER TO SHEET PAE104Z FOR PLAN WITHOUT THE PHOTOVOLTAIC (PV) OPTION.
NORTH STAIR 3
M
O D
P
/2
M
O D
P
A N
D P
/2
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
1 2 3 4 5 C1
PAE301
034533.A03
034533.A03
034533.A04 034533.A03
034533.A03
034533.A04
3 3
3 3
7' -0
5'
-0
6' -6
5'
-0
3' -6
055913.M13
034533.A04
084400.A01
076115.A01
076115.A01
084400.A01
034533.A04
034533.A03
034533.A04
PAE552
C2
PAE552
A3 TYP
055200.R01
055200.R01
055200.R01
034533.A02
034533.A02
034533.A02
'-6
'-6
'-6
A2
PAE521
TYP9
PC-1
AF-1, IG-1
MP-1
MP-1
HM-1
HM-1
HM-1
PC-2
AF-1, IG-1
PC-1
PM-1
PC-1
PC-1
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
6 7 9 108
330.3
034533.A03 034533.A04
034533.A03 034533.A04
034533.A03
034533.A04
8 8
7' -0
5'
-0
6' -6
5'
-0
3' -6
055913.M13
034533.A03
034533.A04
084400.A01
076115.A01
076115.A01
084400.A01
034533.A03
034533.A04
PAE552
A3
PAE552
C2 TYP
055200.R01
055200.R01
055200.R01
034533.A02
'-0
'-2
'-2
'-0
A2
PAE521
TYP
PC-1
PC-1
PC-1
PC-1
PM-1
MP-1
MP-1
AF-1, IG-1
PC-1
HM-1
HM-1
HM-1
HM-1
AF-1, IG-1
034533.A04
PC-2
EXTERIOR FINISH LEGEND
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST MEDIUM - PCI 110
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 141
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 110
ADDITIONAL FINISHES:
PM-1 PREFINISHED METAL
KINGSPAN SLR DARK BRONZE
PC-3
PC-2
PC-1
AF-1 CURTAINWALL / ALUMINUM WINDOW FRAME /
ALUMINUM DOOR FRAME
KINGSPAN SLR DARK BRONZE
HM-1 HM DOOR / HM DOOR FRAME / LOUVER /
LOUVER FRAME
SW 6072 VERSATILE GRAY
INSULATED LAMINATED VISION GLASS
VITRO SOLARBRONZE
IG-1
STANDING SEAM METAL PANEL
KINGSPAN SLR DARK BRONZE
MP-1
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:0
P
M
1/8" = 1'-0"
P A
R K
IN
G
G A
R A
G E
E
N
LA
R G
E D
E
LE
V A
T
IO
N S
PAE214
EAD JAF BKH
12860317
1/8" = 1'-0" C1
PARTIAL ELEVATION -SOUTH
1/8" = 1'-0" A1
PARTIAL ELEVATION -SOUTH
MATERIAL NOTES
034533.A02 PRECAST/PRESTRESSED CONCRETE BEAM
034533.A03 PRECAST/PRESTRESSED CONCRETE COLUMN
034533.A04 PRECAST/PRESTRESSED CONCRETE WALL PANEL
055200.R01 STEEL GUARDRAIL
055913.M13 EXTERIOR TRELLIS
076115.A01 STANDING-SEAM METAL ROOF PANEL
084400.A01 GLAZED ALUMINUM CURTAIN WALL ASSEMBLY
1 STANDING SEAM METAL ROOF PANEL IN VERTICAL APPLICATION.
2 ALUMINUM CANOPY SYSTEM WITH INTEGRAL DRAINAGE FOR PHOTOVOLTAIC
PANEL. PROVIDE IF PARKING GARAGE PV PANEL OPTION IS AWARDED. REFER TO
DETAIL A3/PAE582. REFER TO ELECTRICAL DRAWINGS PEP103A-PEP103B FOR
PHOTOVOLTAIC PANEL SYSTEM INFORMATION.
3 PRECAST GRADE SPANDREL.
4 FOR STEPS, RAMP AND HANDRAILS, REFER TO VOLUME 1, SHEET CS102 AND LP102
FOR ADDITIONAL INFORMATION.
5 OPEN.
PAE201
PAE201
A REFER TO SHEET PAE001 FOR ARCHITECTURAL ABBREVIATIONS AND SYMBOLS.
B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".
REFER TO VOLUME 1, SHEETS CG101-CG102 FOR SLAB ELEVATIONS RELATIVE TO NORTH
AMERICAN VERTICAL DATUM (NAVD) SYSTEM.
C WHERE COLOR IS SHOWN AS BEING SPECIFIC TO ONE MANUFACTURER, AN EQUIVALENT
COLOR BY ANOTHER MANUFACTURER MAY BE SUBMITTED FOR APPROVAL.
MANUFACTURERS AND MATERIALS SPECIFIED ARE NOT INTENDED TO LIMIT THE
SELECTION OF EQUAL COLORS FROM OTHER MANUFACTURERS.
D PROVIDE 1-1/2" PER FOOT MINIMUM SLOPE AT STANDING SEAM METAL ROOF.
E REFER TO SHEETS PAE221-PAE229 FOR PRECAST PANEL ELEVATIONS.
F REFER TO SHEETS PAG101-PAG221 AND PAG701-PAG707 FOR SIGNAGE LOCATIONS AND
ELEVATIONS.
G REFER TO SHEET PAE104Z FOR PLAN WITHOUT THE PHOTOVOLTAIC (PV) OPTION.
KEY NOTES 00
6 PHOTOVOLTAIC PANEL SYSTEM. PROVIDE IF PARKING GARAGE PV PANEL OPTION
IS AWARDED. REFER TO SHEET PEP103 FOR ADDITIONAL INFORMATION.
7 WELDED WIRE PANEL PLANT SYSTEM, CENTER BETWEEN COLUMNS. REFER TO
DETAIL A3/PAE552 AND SHEET PAE552 FOR SECTION DETAIL.
8 WELDED WIRE PANEL PLANT SYSTEM, CENTER BETWEEN COLUMNS. REFER TO
DETAIL C2/PAE552 AND SHEET PAE552 FOR SECTION DETAIL.
9 EXTERIOR BUILDING NUMBER. REFER TO VOLUME 2A, SHEET AG101 FOR
ADDITIONAL INFORMATION.
M
O D
P
/2
M
O D
P
A N
D P
/2
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
034533.A04
076115.A01
076115.U01
076115.A01076115.U02
034533.A04
055013.B01
055013.B01
055013.B01
MP-1
MP-1
PM-1
PM-1
PC-1
034533.A04
PC-1
034533.A02
034533.A07
034533.A02
034533.A07
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
DC.8
323 320.1
034533.A04
084400.A01
076115.A01
076115.A01
034533.A04
081113.A01
081113.A01
081113.A01
076115.U01
1.5
PM-1
PC-1
HM-1
HM-1
HM-1
PC-1
AF-1, IG-1
MP-1
MP-1
034533.A07
034533.A07
034533.A04034533.A04
034533.A04
GROUND FLR
0'-0"
THIRD FLR
23'-0"
ROOF
34'-6"
SECOND FLR
11'-6"
A A.2
320 323.1
076115.U01
076115.A01
076115.A01
084400.A01
034533.A04
034533.A04
081113.A01
1.5
034533.A02
034533.A03
034533.A04
034533.A04
PC-3
PC-1
AF-1, IG-1
HM-1
PC-1
PM-1
MP-1
MP-1
EXTERIOR FINISH LEGEND
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST MEDIUM - PCI 110
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 141
ARCHITECTURAL PRECAST CONCRETE
SANDBLAST LIGHT - PCI 110
ADDITIONAL FINISHES:
PM-1 PREFINISHED METAL
KINGSPAN SLR DARK BRONZE
PC-3
PC-2
PC-1
AF-1 CURTAINWALL / ALUMINUM WINDOW FRAME /
ALUMINUM DOOR FRAME
KINGSPAN SLR DARK BRONZE
HM-1 HM DOOR / HM DOOR FRAME / LOUVER /
LOUVER FRAME
SW 6072 VERSATILE GRAY
INSULATED LAMINATED VISION GLASS
VITRO SOLARBRONZE
IG-1
STANDING SEAM METAL PANEL
KINGSPAN SLR DARK BRONZE
MP-1
GROUND FLR
0'-0"
THIRD FLR
23'-0"
SECOND FLR
11'-6"
6 7
350 351 355351 354 356 357 358 359
555 034533.A04
TYP7
055200.R01
GROUND FLR
0'-0"
THIRD FLR
23'-0"
SECOND FLR
11'-6"
034533.A04
353 359 358 357 356 355 354 351 351 350
5 5 5 5 5 5 5 5 5 5
055200.R01
OPH, SIM OPH, SIM OPH OPH OPH OPH 351
PAE522
B2
T
ST
A
E OF F L OR IDA
R
EG ISTER ED A R C H IT
E C T
B
IL
Y
K
EIT
H HO
L
LLOW
A Y
AR93022
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
CGM
EJA
DSN
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F
M ai nt
H an ga r_
P ar ki ng
F ac ili ty
.rv t
/4
/2
8:
:0
P
M
1/8" = 1'-0"
P A
R K
IN
G
G A
R A
G E
E
N
LA
R G
E D
E
LE
V A
T
IO
N S
PAE215
EAD MCL BKH
12860318
1/8" = 1'-0"C4
ENLARGED ELEVATION
1/8" = 1'-0"C3
ENLARGED ELEVATION
MATERIAL NOTES
034533.A02 PRECAST/PRESTRESSED CONCRETE BEAM
034533.A03 PRECAST/PRESTRESSED CONCRETE COLUMN
034533.A04 PRECAST/PRESTRESSED CONCRETE WALL PANEL
034533.A07 PRECAST/PRESTRESSED CONCRETE FLOOR DOUBLE TEE
055013.B01 STEEL BOLLARD
055200.R01 STEEL GUARDRAIL
076115.A01 STANDING-SEAM METAL ROOF PANEL
076115.U01 GUTTER
076115.U02 DOWNSPOUT
081113.A01 STEEL DOOR
084400.A01 GLAZED ALUMINUM CURTAIN WALL ASSEMBLY
1/8" = 1'-0"C1
ENLARGED ELEVATION
1 STANDING SEAM METAL ROOF PANEL IN VERTICAL APPLICATION.
2 LIGHT FIXTURE. REFER TO SHEETS PEL101, PEL102, AND PEL103 FOR ADDITIONAL
INFORMATION.
3 SURFACE MOUNTED, REMOVABLE, PEDESTAL BOLLARD, TYP. REFER TO DETAIL
A2/PAE553.
4 FIRE RISER. REFER TO SHEETS PFX101, PFX111, AND PFX121 FOR ADDITIONAL
INFORMA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .