Attachment L - VOL4_1363603dwg2of9.pdf
PDF 2 MB Posted
- Attached to
- P475 Aircraft Maintenance Hangar
- Solicitation number
- N4008526R0148
About this file
These are Life Safety Plan drawings for a parking garage at Marine Corps Air Station (MCAS) Beaufort, South Carolina, part of a P-475 Aircraft Maintenance Hangar project. The parking structure is a 3-story, Type IIB construction with 64,346 square feet, classified as a Group S-2 (Storage/Parking) occupancy with a total occupant load of 322 persons. The garage includes four stairwells (PS101-PS104), has a dry-pipe sprinkler system requested by the fire department, and is designed to meet various federal and national building/fire safety codes including UFC, IBC, and NFPA standards. The drawings detail life safety features such as egress routes, travel distances, and compliance with occupancy load requirements, with the project being managed by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic and prepared by Jensen Hughes engineering firm.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
Y
X = REQUIRED EGRESS CAPACITY (PERSONS)
Y = PROVIDED EGRESS CAPACITY (PERSONS)
ROOM AREA (SF)
OCCUPANT FACTOR (SF/PERSON)
NUMBER OF OCCUPANTS (PERSONS)
TRAVEL PATH AND DISTANCE
COMMON PATH OF TRAVEL
SMOKE PARTITION
1-HOUR FIRE BARRIER
POINT OF CONNECTION TO EXISTING
TD = XXFT
CP = XXFT
LIFE SAFETY LEGEND
1,000
XXXX
XXXX
XXXX
Lic. No. 037705
ALISON WAKELINC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head
& Supervisory Facility Planner, PWD Beaufort, SC via email.
EJA
DSN
DSN
12/15/2022
M O
D P
5/
M O
D P
A
N D
M O
D P
0/
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ge r_ P ar ki ng F ac ili ty
F P
R
V T
.rv t
/5
/2
4:
:2
P
M
1/8" = 1'-0"
P A
R K
IN
G
G A
R A
G E
LI
F E
S A
F E
T Y
N O
T E
S A
N D
L E
G E
N D
PGC001
ROP AHE APF
12860280
OCCUPANCY/USE APPROX.
AREA (SF)
OCCUPANT LOAD
FACTOR
(SF/PERSON)
OCCUPANT
LOAD
(PERSONS)
GROUP S-2/PARKING
64,346 322200
APPLICABLE CRITERIA
USE GROUP/OCCUPANCY
FIRE PROTECTION SYSTEMS
INTERIOR FINISH CLASSIFICATION
OCCUPANT LOAD
ARRANGEMENT OF MEANS OF EGRESS
CAPACITY AND NUMBER OF MEANS OF EGRESS
ADDITIONAL LIFE SAFETY CRITERIA
BUILDING HEIGHT AND AREA
FIRE RESISTANCE RATINGS OF BUILDING ELEMENTS
EXTERIOR WALLS
CONSTRUCTION TYPE
UFC 1-200-01 DOD BUILDING CODE (CHANGE 1, 1 OCT 2020)
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES (CHANGE 5, 25 SEP 2020)
IBC INTERNATIONAL BUILDING CODE, 2018
NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS, 2019
NFPA 70 NATIONAL ELECTRICAL CODE, 2020
NFPA 88A STANDARD FOR PARKING STRUCTURES, 2019
NFPA 101 LIFE SAFETY CODE, 2018 (LSC)
ABA ARCHITECTURAL BARRIERS ACT
S-2 (IBC 311.3) / STORAGE (LSC 6.1.13) - ORDINARY HAZARD (LSC 42.1.5)
OPEN PARKING GARAGE (NFPA 88A)
CLIMATE ZONE: A3
ENVIROMENTAL SEVERITY INDEX: C4
DRY-PIPE SPRINKLER SYSTEM
(NOT REQUIRED BY NFPA 88A; SYSTEM REQUESTED BY FIRE DEPARTMENT)
FIRE ALARM SYSTEM
BASED ON LSC TABLE A.7.6:
PROVIDE MEANS OF EGRESS LIGHTING IN ACCORDANCE WITH LSC 7.8 (LSC 42.8.2.8). ARTIFICIAL LIGHTING IS REQUIRED AT LOCATIONS
AND TIMES NECESSARY TO MAINTAIN ADEQUATE ILLUMINATION (LSC 7.8.1.2.1).
PROVIDE EMERGENCY LIGHTING IN ACCORDANCE WITH LSC 7.9 [LSC 42.8.2.9].
PROVIDE SIGNS FOR THE MEANS OF EGRESS IN ACCORDANCE WITH LSC 7.10 (LSC 42.8.2.10). SIGNS MUST HAVE LETTERING ON AN OPAQUE BACKGROUND. INTERNALLY ILLUMINATED SIGNS MUST BE LIGHT EMITTING DIODE (LED) TYPE, ELECTROLUMINESCENCE (LEC), OR COLD CATHODE TYPE. INCANDESCENT FIXTURES ARE NOT PERMITTED. RADIOLUMINOUS EXIT SIGNS ARE NOT PERMITTED.
FIRE EXTINGUISHERS ARE NOT REQUIRED IN APPLICABLE OCCUPANCIES (LSC).
REQUIRED EGRESS
CAPACITY
AVAILABLE EGRESS
CAPACITY
MEANS OF EGRESS
REQUIRED
MEANS OF EGRESS
PROVIDED
ALLOWABLE HEIGHT
ACTUAL HEIGHT
GROUP S-2
TYPE IIB
55 FT
3 STORIES
35 FT
3 STORIES
UNLIMITED
64,346
BUILDING ELEMENT
STRUCTURAL FRAME, INCLUDING COLUMNS, GIRDERS, TRUSSES
STRUCTURAL FRAME SUPPORTING A ROOF ONLY
BEARING WALLS, EXTERIOR
BEARING WALLS, INTERIOR
NON-BEARING WALLS, EXTERIOR
NON-BEARING WALLS, INTERIOR
FLOOR CONSTRUCTION, INCLUDING SUPPORTING BEAMS AND JOISTS
ROOF CONSTRUCTION, INCLUDING SUPPORTING BEAMS AND JOISTS
IBC TYPE IIB
0-HR
0-HR
0-HR
0-HR
0-HR
0-HR
0-HR
0-HR
FIRE SEPARATION DISTANCE (FSD)
FSD < 5 FT
5 FT ≤ FSD < 10 FT
FSD ≥ 10 FT
GROUP S-2/TYPE IIB
ALLOWABLE AREA (SF)
ACTUAL AREA (SF)
LOAD FACTORS (LSC TABLE 7.3.1.2, IBC TABLE 1004.5):
PARKING GARAGES 200-SF/PERSON
MINIMUMS BASED ON LSC TABLE A.10.2.2:
FLOOR LEVEL
CAPACITY OF MEANS OF EGRESS (LSC TABLE 7.3.3.1):
LEVEL COMPONENTS (WIDTH/PERSON) 0.2 IN/PERSON
STAIRWAYS (WIDTH/PERSON) 0.3 IN/PERSON
NUMBER OF MEANS OF EGRESS (LSC 7.4):
1 WHERE AN EXIT CAN BE REACHED WITHIN DISTANCE PERMITTED AS COMMON PATH OF TRAVEL
OTHERWISE 2 FOR AREAS WITH AN OCCUPANT LOAD LESS THAN 500
FLOOR LEVEL
EXITS
CLASS B
EXIT ACCESS
CORRIDORS
OTHER
CLASS C
OCCUPANCY
STORAGE
EXIT ACCESS
TRAVEL DISTANCE (FT)
COMMON PATH OF
TRAVEL (FT)
DEAD-END
CORRIDOR (FT)
OCCUPANCY
OPEN PARKING STRUCTURE
CLASS C
GROUP S-2/PARKING
GROUP S-2/PARKING
OVERALL TOTAL
64,346 322200
64,346 322200
193,038 966-
PARKING GARAGE TYPE IIB
INTERIOR FIRE RESISTANCE REQUIREMENTS
N/A
Lic. No. 037705
ALISON WAKELINC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
ENGINEERS + SURVEYORS
80'0 10'
1/32" = 1'-0" GRAPHIC SCALE
40' 120'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head
& Supervisory Facility Planner, PWD Beaufort, SC via email.
EJA
DSN
DSN
12/15/2022
M O
D P
5/
M O
D P
A
N D
M O
D P
0/
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ge r_ P ar ki ng F ac ili ty
F P
R
V T
.rv t
/5
/2
4:
:2
P
M
P A
R K
IN
G
G A
R A
G E
C
O D
E C
O M
P
LI
A N
C E
S
IT
E P
LA
N
PGC002
ROP AHE APF
12860281
64,346
TD = 195 FT
STAIR 1
PS101
STAIR 2
PS102
STAIR 3
PS103
PARKING
P101
STAIR 4
PS104
1 2 3 4 5 6 7 9 10
A
B
C
D
A.2
C.8
CP = 33 FT
TD = 291 FT
SPKLR
96 SF
P105
ELEC
135 SF
P104
SOLAR INV
212 SF
P103
Lic. No. 037705
ALISON WAKELINC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head
& Supervisory Facility Planner, PWD Beaufort, SC via email.
EJA
DSN
DSN
12/15/2022
M O
D P
5/
M O
D P
A
N D
M O
D P
0/
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ge r_ P ar ki ng F ac ili ty
F P
R
V T
.rv t
/5
/2
4:
:2
P
M
1/16" = 1'-0"
P A
R K
IN
G
G A
R A
G E
LI
F E
S A
F E
T Y
P
LA
N
G R
O U
N D
F L
O O
R
PGC101
ROP AHE APF
12860282
A B
KEYPLAN
1/16" = 1'-0"
A1
PARKING GARAGE - LIFE SAFETY PLAN - GROUND FLOOR - OVERALL
TD = 192 FT
1 2 3 4 5 6 7 9 10
A
B
C
D
A.2
C.8
TD = 260 FT
Lic. No. 037705
ALISON WAKELINC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head
& Supervisory Facility Planner, PWD Beaufort, SC via email.
EJA
DSN
DSN
12/15/2022
M O
D P
5/
M O
D P
A
N D
M O
D P
0/
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ge r_ P ar ki ng F ac ili ty
F P
R
V T
.rv t
/5
/2
4:
:2
P
M
1/16" = 1'-0"
P A
R K
IN
G
G A
R A
G E
LI
F E
S A
F E
T Y
P
LA
N
S E
C O
N D
F L
O O
R
PGC111
ROP AHE APF
12860283
A B
KEYPLAN1/16" = 1'-0"
PARKING GARAGE - LIFE SAFETY PLAN - SECOND FLOOR - OVERALL
TD = 159 FT
1 2 3 4 5 6 7 9 10
A
B
C
D
A.2
C.8
Lic. No. 037705
ALISON WAKELINC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head
& Supervisory Facility Planner, PWD Beaufort, SC via email.
EJA
DSN
DSN
12/15/2022
M O
D P
5/
M O
D P
A
N D
M O
D P
0/
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ge r_ P ar ki ng F ac ili ty
F P
R
V T
.rv t
/5
/2
4:
:2
P
M
1/16" = 1'-0"
P A
R K
IN
G
G A
R A
G E
LI
F E
S A
F E
T Y
P
LA
N
T H
IR
D
F L
O O
R
PGC121
ROP AHE APF
12860284
A B
KEYPLAN1/16" = 1'-0"
PARKING GARAGE - LIFE SAFETY PLAN - THIRD FLOOR - OVERALL
| LIFE SAFETY |
| PGC001 - PARKING GARAGE – LIFE SAFETY NOTES AND LEGEND |
| PGC002 - PARKING GARAGE – CODE COMPLIANCE SITE PLAN |
| PGC101 - PARKING GARAGE – LIFE SAFETY PLAN – GROUND FLOOR |
| PGC111 - PARKING GARAGE – LIFE SAFETY PLAN – SECOND FLOOR |
| PGC121 - PARKING GARAGE – LIFE SAFETY PLAN – THIRD FLOOR |
| 2025-11-06T13:57:38-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:58:15-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:57:39-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:57:39-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:57:40-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:57:41-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:58:16-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:58:17-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:58:17-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
| 2025-11-06T13:58:18-0500 | |
| Alison Wakelin | |
| I, Alison Wakelin, am signing to approve this document. |
2025-11-22T16:00:47-0500
2025-11-22T16:01:14-0500
2025-11-22T16:00:48-0500
2025-11-22T16:00:48-0500
2025-11-22T16:00:48-0500
2025-11-22T16:00:49-0500
2025-11-22T16:01:14-0500
2025-11-22T16:01:14-0500
2025-11-22T16:01:15-0500
2025-11-22T16:01:15-0500
File details come from the government source that posted it. Updated .