Attachment K - VOL3_1363603dwg4of11.pdf

PDF 11 MB Posted

Attached to
P475 Aircraft Maintenance Hangar
Solicitation number
N4008526R0148
Issued by

About this file

These architectural drawings detail the design for a Naval Facilities Engineering Systems Command (NAVFAC) Operation Support Facility (OSF) and Shop Annex building located at Marine Corps Air Station Beaufort, South Carolina. The single-story facility is approximately 85'-4" long and 52' wide, featuring a standing seam metal roof, precast concrete insulated wall panels, and includes various interior spaces such as an office, shop annex, mechanical room, toilets, electrical room, and janitor's closet. The building is designed with a ground floor plan, includes exterior metal fencing around a mechanical yard, and incorporates features like extruded aluminum wall louvers, translucent panels, and specific attention to air barrier and insulation requirements to meet energy efficiency standards. The project is part of a larger aircraft maintenance hangar complex, with design documents prepared in December 2022 and indicating construction completion targeted for November 2025.

View the file

Other files

File Type Posted
N4008526R0148_0009.pdf PDF
1363603Amend0006dwg_VOL 3 ARCHITECTURAL.pdf PDF
1363603Amend0006dwg_VOL 3 STRUCTURAL_1of2.pdf PDF
1363603Amend0005dwg_VOL 4_COMBINED.pdf PDF
1363603Amend0005dwg_VOL 3_COMBINED.pdf PDF
1363603Amend0005dwg_VOL 1_COMBINED.pdf PDF
Solicitation Amendment N4008526R0148_0005.pdf PDF
N4008526R0148-0003.pdf PDF
26R0148 P475 Site visit log_Redacted.pdf PDF
JandA ML-23-33 P475 Interior Finishes Brand Name or Equal_Redacted.pdf PDF
Attachment P - SECNAV 5512.pdf PDF
Attachment N - VOL6_1363603dwg5of10.pdf PDF
Attachment N - VOL6_1363603dwg6of10.pdf PDF
Attachment N - VOL6_1363603dwg7of10.pdf PDF
Attachment L - VOL4_1363603dwg7of9.pdf PDF
Attachment K - VOL3_1363603dwg3of11.pdf PDF
Attachment K - VOL3_1363603dwg11of11.pdf PDF
Attachment K - VOL3_1363603dwg1of11.pdf PDF
Attachment J - VOL1_1363603dwg7of14.pdf PDF
Attachment J - VOL1_1363603dwg3of14.pdf PDF
Attachment J - VOL1_1363603dwg1of14.pdf PDF
Attachment J - VOL1_1363603dwg2of14.pdf PDF
Attachment G - Price Proposal Form_P475.pdf PDF
Attachment A - PPI_P475 F35 Aircraft Maint Hanger.xlsx XLSX spreadsheet
Attachment C - Past Performance Questionnaire (PPQ).pdf PDF
Attachment D - Historical Small Business Utilization.pdf PDF
Attachment N - VOL6_1363603dwg2of10.pdf PDF
Attachment N - VOL6_1363603dwg4of10.pdf PDF
Attachment N - VOL6_1363603dwg9of10.pdf PDF
Attachment N - VOL6_1363603dwg8of10.pdf PDF
Attachment M - VOL5_1363603dwg2of2.pdf PDF
Attachment L - VOL4_1363603dwg1of9.pdf PDF
Attachment K - VOL3_1363603dwg9of11.pdf PDF
Attachment J - VOL1_1363603dwg4of14.pdf PDF
Attachment J - VOL1_1363603dwg11of14.pdf PDF
Attachment J - VOL1_1363603dwg5of14.pdf PDF
Attachment F - Individual Small Business Subcontracting Plan.pdf PDF
Attachment O - P475 RTA Specs VOL 1 OF 2.pdf PDF
Attachment N - VOL6_1363603dwg3of10.pdf PDF
Attachment N - VOL6_1363603dwg10of10.pdf PDF
Attachment M - VOL5_1363603dwg1of2.pdf PDF
Attachment L - VOL4_1363603dwg9of9.pdf PDF
Attachment L - VOL4_1363603dwg3of9.pdf PDF
Attachment L - VOL4_1363603dwg8of9.pdf PDF
Attachment K - VOL3_1363603dwg10of11.pdf PDF
Attachment K - VOL3_1363603dwg7of11.pdf PDF
Attachment K - VOL3_1363603dwg6of11.pdf PDF
Attachment J - VOL1_1363603dwg8of14.pdf PDF
Attachment J - VOL1_1363603dwg14of14.pdf PDF
Attachment J - VOL1_1363603dwg6of14.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF. LINE

SEE 00/0-00-000

AE101

A1

AE101

A1

AE101

1 Ref

R e f

1 Ref

R e f

GENERAL SYMBOLS

EXTERIOR ELEVATION

REFERENCE

INTERIOR ELEVATION

REFERENCE

SECTION REFERENCE

REFERENCE FOR DETAIL OR

ENLARGED PLAN

DETAIL / SECTION NUMBER

SHEET NUMBER

LEADER OR NOTATION

PARTIAL PLAN REFERENCE LINE

BUILDING LEVEL OR ELEVATION. ALL

BUILDINGS HAVE FIRST FLOOR SET

AT 0'-0". COORDINATE WITH CIVIL

DRAWINGS FOR FLOOR LEVEL

RELATIVE TO SITE AND EACH OTHER.

REVISION IDENTIFIER

KEY NOTE

CENTERLINE

NEW COLUMN REFERENCE AND GRID

LINES

ROOM NUMBER

ROOM NAME LINE 1

STORAGE

092900.A01 MATERIAL NOTES

INDEPENDANT SUFFIX MATERIAL OR

NOTE SPECIFIER FOR CONDOC LIST

SPECIFICATION SECTION PREFIX

VAPOR BARRIER (DETAILS)

WORK ABOVE (PLANS)

LATH (DETAILS)

BITUMINOUS DAMPROOFING

(DETAILS)

SPOT ELEVATION RELATED TO

DISTANCE ABOVE FIRST FLOOR

BREAK LINE

N

PLAN

NORTH

PLAN NORTH

TRUE NORTH

A1

AE312

ROOM NAME LINE 2STORAGE

PAE100A1

SHEET SEQUENCE NUMBER

SHEET TYPE

LEVEL 2, DISCIPLINE DESIGNATOR

BUILDING IDENTIFIER PREFIX, REFER

TO BUILDING IDENTIFIER PREFIX

LEGEND

BUILDING IDENTIFIER PREFIX LEGEND

BUILDING 414 M

BUILDING 727 N

OSF / ANNEX O

PARKING GARAGE P

HANGAR -

BUILDING NAME BUILDING PREFIX

MAXIMUM OF 8 CHARACTERS

TYPICAL SHEET NUMBER FORMAT

0/0" = 1'-0"00

VIEW NAME

1.

ARCHITECTURAL SYMBOLS

GLAZING AND LOUVER PREFIXES

W = WINDOW

L = LOUVER

B = BORROWED LITE

S = STOREFRONT

G = GATE

C = CURTAINWALL

T = TRANSLUCENT PANEL

PARTITION TYPE NAMING CONVENTION

ASSEMBLY TYPE

STUD OR CMU SIZE

MODIFIERS

FIRE RATING

A3AC.1

PARTITION SYMBOL ON PLAN

PARTITION TYPE SYMBOL

DOOR NUMBERS:

THE PRIMARY DOOR NUMBER IS

THE ROOM NUMBER. A DECIMAL

IS ADDED TO DISTINGUISH

ADDITIONAL DOORS IN THE

ROOM.

00 PRECAST WALL PANEL

1 HOUR FIRE BARRIER

PARTITION LEGEND

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:3

P

M

As indicated

A R

C H

IT

E

C T

U R

A L

A B

B R

E V

IA

T

IO

N

S A

N D

S Y

M B

O

LS

OAE001

EAD MEC BKH

12860131

GENERAL ABBREVIATIONS

# AND SYMBOLS

# NUMBER / POUND

& AND

@ AT

A

A AIR

A/C AIR CONDITIONED

A/E ARCHITECT-ENGINEER

ACM ASBESTOS-CONTAINING MATERIAL(S)

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

AMP AMPERE

AO ACCESS OPENING

APPROX APPROXIMATELY

ARCH ARCHITECTURAL

B

BAL BALANCE

BD BOARD

BKOP BACK OF PRECAST / BACK OF PANEL

BLDG BUILDING

BLK BLANK

BM BEAM

BO BOTTOM OF

BOP BOTTOM OF PRECAST

BOS BOTTOM OF STEEL

BRG BEARING

BTUH BRITISH THERMO UNIT / HOUR

C

CG CORNER GUARD

CJ CONTROL / CONSTRUCTION JOINT

CL CENTER LINE / CLOSET

CLG CEILING

CLL COLUMN LINE

CLR CLEAR

cm CENTIMETER

CMU CONCRETE MASONRY UNIT

CNTRL CONTROL

CO2 CARBON DIOXIDE

COMM COMMUNICATIONS

CONC CONCRETE

COND CONDITIONED

CONF CONFERENCE

CONT CONTINUED / CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

CORR CORRIDOR

CTJ CONTRACTION JOINT

CTR CENTER

D

D DEEP / DEPTH

dBA UNIT OF SOUND

DEG DEGREE

DIA DIAMETER

DIMS DIMENSIONS

DN DOWN

DR DOOR

DWG DRAWING(S)

DWR DRAWER

GENERAL ABBREVIATIONS

E

EA EACH

EE EACH END

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

EOS EDGE OF SLAB

EQ EQUAL

EQUIP EQUIPMENT

ETC ET CETERA

ETR EXISTING TO REMAIN

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXIST EXISTING

F

F FILLER

FAX FACSIMILE

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISHED FLOOR

FHC FIRE HOSE CABINET

FIN FINISHED

FLR FLOOR

FO FACE OF

FOS FACE OF SLAB / FACE OF STUD

FP FIRE PROTECTION

FT FOOT / FEET

G

G GAS

GA GAGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

H

H HIGH

HC HANDICAP

HDWR HARDWARE

HE HORIZONTAL EXIT

HM HOLLOW METAL

HR HOUR

I

IC INTERCOM

ID INSIDE DIAMETER

IDS INTRUSION DETECTION SYSTEM

IMP INSULATED METAL PANEL

IN INCH(ES)

INFO INFORMATION

INV INVERTER

J

JAN JANITOR

JT JOINT

K kPA KILOPASCAL

L

LB POUND

LF LINEAR FEET

LG LARGE

LKR LOCKER(S)

LL ANGLE

GENERAL ABBREVIATIONS

M

M MEN'S

m METERS

MAINT MAINTENANCE

MAX MAXIMUM

MECH MECHANICAL

MED MEDIUM

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

mm MILLIMETERS

MO MASONRY OPENING

MTL METAL

N

N NORTH

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O

OC ON CENTER

OD OUTSIDE DIAMETER

OFF OFFICE

OPH OPPOSITE HAND

OPNG OPENING

OSF OPERATION SUPPORT FACILITY

P

P.D. PANEL DIMENSION

PL PLATE

PLAM PLASTIC LAMINATE

PR PAIR

PSF POUNDS per SQUARE FOOT

PSI POUNDS per SQUARE INCH

PT PRESSURE TREATED / PAINT

Q

QTR QUARTER

QTY QUANTITY

R

R RISER / RADIUS

R.O. ROUGH OPENING

RAL FEDERAL COLOR PALETTE

RCP REFLECTED CEILING PLAN

RE RESIDENT ENGINEER

RECY RECYCLING

REQ REQUIRED

RM ROOM

RO ROUGH OPENING

RTN RETURN

S

S SOUTH / SINK

SEC SECONDARY

SF SQUARE FEET

SHWR SHOWER

SIM SIMILAR

SJ SEISMIC JOINT

SPECS SPECIFICATION

SQ SQUARE

SST STAINLESS STEEL

ST STAINED

STC SOUND TRANSMISSION CLASS

STDT STUDY

STL STEEL

STOR STORAGE

SWGR SWITCHGEAR

GENERAL ABBREVIATIONS

T

T TREAD

TEL TELEPHONE

TEMP TEMPERATURE / TEMPORARY

THD THRESHOLD

THK THICKNESS

THRU THROUGH

TLT TOILET

TO TOP OF

TOC TOP OF CONCRETE (CURB)

TOF TOP OF FOOTING

TOM TOP OF MASONRY

TOP TOP OF PRECAST

TOS TOP OF STEEL

TYP TYPICAL

U

U HEAT TRANSFER COEFFICIENT

U/C/B UNDER COUNTER BASE

UC UNDERCUT

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UR URINAL

V

V VACUUM

VAR VARIES

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VTR VENT THRU ROOF

W

W WEST

W WIDTH

W WOMEN'S

W/ WITH

W/O WITHOUT

WD WOOD

WH WALL HUNG / WATER HEATER

WP WATERPROOF / WORKING UNIT

WT WEIGHT

WWF WELDED WIRE FABRIC

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

N-1

N-A

N-B

OAS401

D1

OAS401

A3

33'-0" 3"

'-1

1/

2"

8'-0" 8'-0" 8'-0" 8'-8" 3 1/4"

034500.A10

042000.D03

A3

OAS402

A4

OAS402

OAS402

B2

OAE501

C1OAS402

C2

323130.A03

323130.A03

2" 8'

-2

/4

2"

O102.3

OAS401

B1

3" 2' -0

4'

-0

8' -0

8'

-0

8' -0

32'-8"

'-0

/2

MECHANICAL

YARD

323130.A11

NOTE:

PROVIDE AS SHOWN ONLY IF OSF OPTION IS ACCEPTED.

REFER TO VOLUME 6, SHEET OAS401X FOR BASE BID PLAN.

2' -9

6'

-4

7'-1"

3'-8"

6'-4"

4'-10"

'-4

GROUND FLR

0'-0"

A3

OAS402

323130.A03

8'-0" 8'-0" 8'-0" 4'-0" 2'-0" 3"2" 8'-2 3/4" 2"

OAS402

C4

OAS402

A2

2"

39'-0 1/2"

5 5

323130.A11

FNC-1

FNC-1

ST-1

092423.A01

GROUND FLR

0'-0"

N-1

8'-8" 8'-0" 8'-0" 8'-0" 323130.A03

033000.B01

OAS402

C3

FNC-1

T.O. FOOTING

-2'-0"

TYP

32'-8"

A3

OAS402

033000.V01

GROUND FLR

0'-0"

N-1

A4

OAS402

042000.C04

034500.A10

4" 8'

-0

8' -4

EQ EQ EQ EQ

092423.A01

092423.M12

PC-1

ST-1

EXTERIOR FINISH LEGEND

ARCHITECTURAL PRECAST CONCRETE

SANDBLAST LIGHT - PCI 110

ADDITIONAL FINISHES:

PC-1

FNC-1 EXTERIOR METAL FENCE

RAL 7044

ST-1 STUCCO

STUCCO TO MATCH SW 6072 VERSATILE GRAY

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

N

PLAN

NORTH

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/4

/2

4:

:5

P

M

As indicated

O S

F

S H

O P

A N

N E

X

M E

C H

A N

IC

A

L Y

A R

D P

LA

N

A N

D E

LE

V

A T

IO

N

S

OAS401

EAD MEC BKH

12860132

1/4" = 1'-0" B3

ENLARGED PLAN - MECHANICAL YARD

A

B

KEYPLAN

MATERIAL NOTES

033000.B01 CONCRETE SLAB

033000.V01 VAPOR RETARDER

034500.A10 PRECAST CONCRETE INSULATED WALL PANEL

042000.C04 PRECAST CONCRETE COPING

042000.D03 CMU 8"

092423.A01 STUCCO

092423.M12 REVEAL MOLDING

323130.A03 DECORATIVE METAL FENCE

323130.A11 DOUBLE SWING GATE

1 LOAD BANK DISCONNECT CABINET AND CONCRETE PAD. REFER TO VOLUME 1, SHEETS

ES406 AND EP602 FOR ADDITIONAL INFORMATION.

2 GENERATOR ON CONCRETE PAD. REFER TO VOLUME 1, SHEET ES406 FOR ADDITIONAL

INFORMATION.

3 CHILLER ON CONCRETE PAD. REFER TO VOLUME 1, SHEET MS102 FOR ADDITIONAL

INFORMATION.

4 DECORATIVE METAL FENCE DOUBLE SWING GATE. REFER TO DETAIL C4/OAS402 FOR

GATE ELEVATION AND HARDWARE INFORMATION.

5 HINGE CLEARANCE.

6 CONCRETE PAVEMENT, 12" THICK, OVER 4" (MIN) AGGREGATE BASE COURSE. REFER TO

VOLUME 1, SHEET CS104, FOR ADDITIONAL INFORMATION.

7 6" EMERGENCY CONNECTION. COORDINATE FENCE OPENINGS.

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".

REFER TO CIVIL PLANS FOR SLAB ELEVATIONS RELATIVE TO NORTH AMERICAN VERTICAL

DATUM (NAVD) SYSTEM.

C REFER TO VOLUME 1, SHEETS AS100 AND AS101A FOR ARCHITECTURAL SITE PLAN.

D REFER TO VOLUME 1, SHEETS CS014 AND CG104 FOR SITE LAYOUT AND GRADING

INFORMATION.

E REFER TO VOLUME 1, SHEET LP104 FOR LANDSCAPE AND HARDSCAPE INFORMATION.

F REFER TO VOLUME 1, SHEET ES406 FOR MECHANICAL YARD ELECTRICAL EQUIPMENT

PLAN.

G REFER TO VOLUME 1, SHEET MS102 FOR MECHANICAL YARD MECHANICAL EQUIPMENT

PLAN.

1/4" = 1'-0" A3

EAST ELEVATION

1/4" = 1'-0" D1

NORTH ELEVATION

1/4" = 1'-0" B1

SOUTH ELEVATION

OAS401

OAS401, VOLUME 6: OAS401Z

VOLUME 1: AS100 AND AS101A, OAE101

OAS401, VOLUME 6: OAS401Z

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

GROUND FLR

0'-0"

1' -0

6'

-2

/4

3/

4" 1"

323130.A03

8' -0

FO

O

TI

N

G D

EP

TH

3' -0

" M

IN

M

IN2"

T.O. FOOTING

-2'-0"

033000.A14

033000.B01 033000.J05

GROUND FLR

0'-0"

042000.D03

042000.C04

4"

OAS402

A2 SIM

042000.G10

8'-0"

1"

092423.A11

092423.A01

092423.M01

T.O. FOOTING

-2'-0"

033000.A14

033000.B01

033000.J05

042000.D03

323130.A03

3"

2 1/2"

4"

092423.A11

092423.M01

092423.M04

092423.M04

6"

092423.A01

033000.B01

1/8"

1/2"

MIN

1 1/2"

042000.D03

3"

033000.W03

079200.Q02

042000.G10

3" 1"

10 5/8"

323130.A03

8'-0"

092423.M01

092423.A11

092423.A01

PC-1

SLOPE SLOPE

2"

2" 3"

OVERALL OUT TO OUT

8'-2 3/4"

323130.A11

2"3 3/4" TYP

1"

3/ 4"

6' -2

/4

1'

-0

8' -0

GATE HARDWARE:

* PROVIDE PLATE-WELDED LATCHES WITH INTERLOCKING COMPONENTS

TO MEET BASE SECURITY STANDARDS.

* PROVIDE FOOT BOLTS WITH HOLD IN POSITION SLOTS. PROVIDE SLEEVE

FOR FOOT BOLT IN OPEN AND CLOSED POSITION (BOTH SIDES).

FNC-1

GROUND FLR

0'-0"

8'-0" O.C.

2" 3 3/4" TYP

1' -0

6'

-2

/4

3/

4" 1"

8' -0

323130.A03

FNC-1

034500.A10

079200.Q02

3 1/4"

323130.A03

033000.B01

033000.J05

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

1/2" = 1'-0" GRAPHIC SCALE

1' 2' 4' 8'6'

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:2

P

M

As indicated

O S

F

S H

O P

A N

N E

X

M E

C H

A N

IC

A

L Y

A R

D W

A

LL

S E

C T

IO

N

S A

N D

D E

T A

IL

S

OAS402

EAD MCL BKH

12860133

1/2" = 1'-0" A3

FENCE SECTION

1/2" = 1'-0"

A4

WALL SECTION

1 HINGE CLEARANCE.

2 LATCH CLEARANCE.

3 WELDED ON BOXED HINGE.

4 EMBEDDED POST BELOW GRADE.

5 CONCRETE POLE FOOTING.

6 PAINTED.

7 SAW-CUT DRIP, ON BOTH SIDES OF WALL CAP.

8 STAINLESS STEEL DRIP FLASHING ON BOTH SIDES OF CAP. PROVIDE SEALANT BELOW

DRIP.

9 STAINLESS STEEL ROD WITH SEALANT AROUND PENETRATIONS THRU FLASHING.

10 CONCRETE PAVEMENT, 12" THICK, OVER 4" (MIN) AGGREGATE BASE COURSE. REFER TO

VOLUME 1, SHEET CS104, FOR ADDITIONAL INFORMATION.

11 8" CONC. SLAB AND AGGREGATE BASE COURSE.

MATERIAL NOTES

033000.A14 GRADE BEAM

033000.B01 CONCRETE SLAB

033000.J05 PREFORMED JOINT FILLER

033000.W03 DOWELS

034500.A10 PRECAST CONCRETE INSULATED WALL PANEL

042000.C04 PRECAST CONCRETE COPING

042000.D03 CMU 8"

042000.G10 GROUT SOLID

079200.Q02 BACKSTOP AND SEALANT

092423.A01 STUCCO

092423.A11 SELF FURRING DIAMOND MESH LATH

092423.M01 CASING BEAD

092423.M04 CORNERBEAD

323130.A03 DECORATIVE METAL FENCE

323130.A11 DOUBLE SWING GATE

1 1/2" = 1'-0" C2

PLAN DETAIL

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".

REFER TO CIVIL PLANS FOR SLAB ELEVATIONS RELATIVE TO NORTH AMERICAN VERTICAL

DATUM (NAVD) SYSTEM.

C REFER TO VOLUME 1, SHEETS AS100 AND AS101A FOR ARCHITECTURAL SITE PLAN.

D REFER TO VOLUME 1, SHEETS CS014 AND CG104 FOR SITE LAYOUT AND GRADING

INFORMATION.

E REFER TO VOLUME 1, SHEET LP104 FOR LANDSCAPE AND HARDSCAPE INFORMATION.

F REFER TO VOLUME 1, SHEET ES406 FOR MECHANICAL YARD ELECTRICAL EQUIPMENT

PLAN.

G REFER TO VOLUME 1, SHEET MS102 FOR MECHANICAL YARD MECHANICAL EQUIPMENT

PLAN.

1'0

1½" = 1'-0" GRAPHIC SCALE

6" 2'

3" = 1'-0" A2

MASONRY CAP DETAIL

3/8" = 1'-0" C4

GATE ELEVATION

0 1'

3/8" = 1'-0" GRAPHIC SCALE

2' 4' 6' 8' 10'

1'8"4"

3" = 1'-0" GRAPHIC SCALE

0 2"

OAS401, VOLUME 6: OAS401X

OAS401, VOLUME 6: OAS401XOAS401, VOLUME 6: OAS401XOAS402

OAS401X 3/8" = 1'-0"

C3

TYPICAL FENCE PANEL

OAS401, VOLUME 6: OAS401X

1 1/2" = 1'-0"B2

PLAN DETAIL

OAS401X

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

OAE201

B1

OAE201

A1

OAE202

A1

OAE202

B1

N-E

N-1 N-5

N-A

N-B

N-C

N-F

D1

OAE301

B1

OAE301

N-3

N-D

A3

OAE301

SHOP ANNEX

O102

OSF

O111

OFFICE

O107 COMM

O106

JAN

O105 W TLT

O104

M TLT

O103 ELEC

O108

1'-6" 20'-7" 20'-7" 20'-7" 20'-7" 1'-6"

85'-4"

'-0

'-4

'-0

'-2

9' -9

'-0

1' -6

N-2 N-4

MECH

O109

OAS401

B3

A1

OAE301

1'

-3

'-0

'-0

1' -3

OAE201

C1

1' -6

SHOP ANNEX ENTRY

O101

N-D.1

1' -6

1'

-6

FE

FE FE FE

FE

FE FE

COVERED

AREA

MECHANICAL

YARD

OAE101B

C2

OAE101A

B2

OAE201

B1

OAE201

A1

OAE202

A1

OAE202

B1

N-E

N-1 N-5

N-A

N-B

N-C

N-F

D1

OAE301

B1

OAE301

N-3

N-D

A3

OAE301

N-2 N-4

1"

1' -0

1"

1' -0

076115.A01

076000.U01

076000.U01

A1

OAE301

20'-7" 20'-7" 20'-7" 20'-7"

'-0

9'

-9

'-2

'-0

'-4

'-0

8'

-3

N-D.1

A3

OAE523

PLUMBING FIXTURE SUMMARY OSF / SHOP ANNEX

FIXTURE COUNT PROVIDED [PER PROGRAM FOR DESIGN] (PFD)

RESTROOMS:

MALE:

GROUND FLOOR:

(1) WATER CLOSETS

(1) LAVATORIES

FEMALE:

GROUND FLOOR:

(1) WATER CLOSETS

(1) LAVATORIES

(1) "HI-LO" WATER FOUNTAINS WITH BOTTLE FILLER PROVIDED

(1) SERVICE SINKS PROVIDED

FIXTURE COUNT REQUIRED

UFC 3-420-01 - APPENDIX A-3, CHAPTER 4-D AND TABLES 403.1 AND 403.2

TOTAL NUMBER OF EMPLOYEES: 34

PER TABLE 403.1 AND TABLE 403.2:

MINIMUM NUMBER OF FIXTURES REQUIRED PER TABLE 403.1 AND 403.2

(2) WATER CLOSETS

(2) LAVATORIES

(1) DRINKING FOUNTAINS

FOR NAVY FACILITIES (CHAPTER 4-D):

OCCUPANCY: "BUSINESS"

MINIMUM NUMBER OF FIXTURES REQUIRED FOR NAVY FACILITIES

(2) WATER CLOSETS

(2) LAVATORIES

(1) DRINKING FOUNTAINS

(1) SERVICE SINK

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

0 10'

1/16" = 1'-0" GRAPHIC SCALE

20' 40' 60'

N

PLAN

NORTH

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:4

P

M

As indicated

O S

F

S H

O P

A N

N E

X

F

LO

O R

P

LA

N A

N D

R O

O F

P

LA

N

O V

E R

A

LL

OAE101

EAD KJF BKH

12860134

MATERIAL NOTES

076000.U01 GUTTER

076115.A01 STANDING-SEAM METAL ROOF PANEL

A

B

KEYPLAN

1/16" = 1'-0"A1

FLOOR PLAN - GROUND FLOOR - OVERALL

1/16" = 1'-0"A3

ROOF PLAN - OVERALL

A REFER TO SHEETS OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B REFER TO VOLUME 1, SHEETS AS100 AND AS101A FOR ARCHITECTURAL SITE PLAN.

C REFER TO VOLUME 1, SHEETS CS104 AND CG104 FOR SITE LAYOUT AND GRADING

INFORMATION.

D REFER TO VOLUME 1, SHEETS LP104 AND LF101 FOR LANDSCAPE, HARDSCAPE, SITE

FURNISHING INFORMATION.

E REFER TO SHEET OGC001 FOR CODE SUMMARY AND OGC101 FOR LIFE SAFETY PLAN.

F REFER TO SHEETS OAE101A-OAE101B FOR PARTITION TYPES.

G REFER TO SHEETS OAE471-OAE472 FOR AIR BARRIER DIAGRAMS.

H SLOPED ROOFING COMPOSITION IS AN ALUMINUM STANDING SEAM METAL ROOFING

PANEL ON 5/8" GLASS MAT COVER BOARD OVER 4" POLYISOCYANURATE RIGID BOARD

INSULATION ON METAL DECK. REFER TO SPECIFICATION SECTION 07 61 15. REFER TO

STRUCTURAL DRAWINGS FOR DECK INFORMATION.

I R-VALUE FOR ALL ROOF INSULATION IS TO BE EQUAL TO R-25 MINIMUM CONTINUOUS.

INSULATION FOR DESIGN PURPOSES IS BASED ON 1" POLYISOCYANURATE INSULATION

= R-6.

J ARROWS ON ROOF PLAN INDICATE ROOF SLOPE. STANDING SEAM METAL ROOF TO BE

1" PER FOOT MINIMUM.

K ARCHITECTURAL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF INSULATED

PRECAST PANEL AND FACE OF METAL STUD, UNO.

1 VTR. REFER TO SHEET OPP101A-OPP101B FOR ADDITIONAL INFORMATION. REFER TO

C3/OAE541 FOR ROOF PENETRATION DETAIL.

2 RADIANT HEATER VENT. REFER TO SHEET OMH101A AND OMH502 FOR ADDITIONAL

INFORMATION. REFER TO C3/OAE541 FOR ROOF PENETRATION DETAIL.

3 WATER HEATER FLUE. REFER TO SHEET OMH101B FOR ADDITIONAL INFORMATION.

REFER TO SHEET C3/OAE541 FOR ROOF PENETRATION DETAIL.

4 CONCEALED GUTTER.

OAE101A, OAE101B

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

N-E

N-1 N-5

N-C

N-F

OSF

O111

N-3

N-D

O111.6

O

1.

N-2 N-4

M8.1B

4' -4

1'

-6

'-8

7'

-9

1' -8

OAE501

A2

OAE501

C4

A1

OAE311

85'-4"

034500.A10

034500.A10

042000.D03

OAE201

C1 2

'-0

'-1 1"

'-0

1'-6" 20'-7" 20'-7" 20'-7" 20'-7" 1'-6"

O111.4

O111.1

O

1.

O

1.

1/ 8"

1'

-0

'-0

3' -0

2'

-0

3'-0" 1'-7"

3'-6" 3'-0" 3'-0"

4' -0

4'

-0

4' -0

3'

-6

4' -4

3'

-0

TY

P

1' -6

'-8

1'

-8

4' -4

3'

-8

104400.A01 104400.A02

104400.A01 104400.A02

FE FE

FEC

COVERED

AREA

OAE621

B2 TYP

N-D.1

A2

OAE311

A3

OAE311

A2

OAE312

076115.U02 4

TY

P

1' -6

13'-0" 4'-4"

OAE101A

A2

OAE532

B2

TYP

104400.B016

TYP

OAE101B

A2 7

1 HOUR FIRE BARRIER

PARTITION LEGEND

N-1 N-5

N-C

N-3N-2 N-4

85'-4"

OAE501

A1

1' -8

1'-6" 20'-7" 20'-7" 20'-7" 20'-7" 1'-6"

034500.A10

076115.A01

076115.A01 042000.D03

034500.A10

2' -1

1"

OAE501

A1OPH

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

N

PLAN

NORTH

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:4

P

M

As indicated

O S

F

S H

O P

A N

N E

X

F

LO

O R

P

LA

N

G R

O U

N D

F

LO

O R

S

E C

T O

R A

OAE101A

EAD KJF BKH

12860135

1/8" = 1'-0" B2

FLOOR PLAN - GROUND FLOOR - SECTOR A

A

B

KEYPLAN

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B DASHED LINES REPRESENT ITEMS ABOVE.

C ARCHITECTURAL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF INSULATED

PRECAST PANEL AND FACE OF METAL STUD, UNO.

D ARCHITECTURAL DIMENSIONS ARE TO COLUMN GRID, FACE OF MASONRY / CONCRETE,

FACE OF METAL STUD, UNO.

E REFER TO SHEET OGC001 FOR CODE SUMMARY AND OGC101 FOR LIFE SAFETY PLAN.

F REFER TO SHEET OAE101 FOR OVERALL ELEVATION AND BUILDING SECTION

REFERENCES.

G REFER TO SHEET OAE601 FOR DOOR SCHEDULE, DOOR/FRAME ELEVATIONS,

TRANSLUCENT PANEL ELEVATIONS, AND LOUVER ELEVATIONS.

H REFER TO SHEETS OAE621-OAE622 FOR DOOR DETAILS AND SHEET OAE631 FOR LOUVER

AND TRANSLUCENT PANEL DETAILS.

I EXTERIOR WALL FURRING TO BE PARTITION TYPE B2, UNO. REFER TO SHEET OAE801

FOR PARTITION TYPES.

J PARTITIONS TO BE M8, UNO. REFER TO SHEET OAE801 FOR PARTITION TYPES.

K REFER TO SHEET OAE821 FOR THROUGH PENETRATION FIRESTOP SYSTEM SCHEDULE.

L REFER TO SHEET OAF601 FOR FINISH SCHEDULES AND FINISH IDENTIFICATION

SCHEDULES.

M PLUMBING FIXTURES SHOWN FOR REFERENCE ONLY. REFER TO PLUMBING SHEETS FOR

MORE INFORMATION.

N SPECIALTY EQUIPMENT SHOWN FOR REFERENCE ONLY. REFER TO SHEET OQJ101B FOR

EQUIPMENT PLAN AND OQJ201 FOR TYPICAL EQUIPMENT MOUNTING HEIGHTS AND

ELEVATIONS.

O REFER TO SHEET OQJ201 FOR TYPICAL TOILET ROOM MOUNTING HEIGHTS AND

ELEVATIONS.

MATERIAL NOTES

034500.A10 PRECAST CONCRETE INSULATED WALL PANEL

042000.D03 CMU 8"

076115.A01 STANDING-SEAM METAL ROOF PANEL

076115.U02 DOWNSPOUT

104400.A01 FIRE EXTINGUISHER

104400.A02 FIRE EXTINGUISHER MOUNTING BRACKET

104400.B01 FIRE EXTINGUISHER CABINET

1 NITROGEN STORAGE TANK. REFER TO SHEETS OFX101 AND OFX501 FOR ADDITIONAL

INFORMATION.

2 CONCRETE-FILLED STEEL BOLLARD, IMPACT-RATED. REFER TO DETAIL C4/OAE561.

3 REFER TO DETAIL A2/OAE101B FOR COVERED AREA FLOOR PLAN AT UPPER LOUVERED

WALL.

4 REFER TO VOLUME 1, SHEET CG513 FOR DOWNSPOUT BOOT DETAILS.

5 REFER TO A2/OAE101A FOR PARTIAL FLOOR PLAN OF UPPER PORTION OF WALL.

6 FIRE EXTINGUISHER CABINET, SURFACE MOUNTED, ALL-WEATHER/OUTDOOR TYPE.

7 REFER TO A2/OAE101B FOR PARTIAL FLOOR PLAN OF UPPER PORTION OF COVERED

AREA.

8 FIRE SPRINKLER RISERS. REFER TO SHEETS OFX101 AND OFX501 FOR ADDITIONAL

INFORMATION.

9 NITROGEN GENERATOR. REFER TO SHEETS OFX101 AND OFX501 FOR ADDITIONAL

INFORMATION.

1/8" = 1'-0" A2

FLOOR PLAN - HIGH WALL

OAE101

OAE101A

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

N-A

N-B

N-C

SHOP ANNEX

O102

OFFICE

O107

COMM

O106

JAN

O105

W TLT

O104

M TLT

O103

ELEC

O108

N-3

20'-7" 20'-7" 20'-7" 20'-7" 1'-6"

1' -6

'-0

'-4

'-2

'-6

O102.3

O

O

O104

O103

O

O

OAE101B

C1

N-2 N-4

1'-6"

MECH

O109

N8

A3

M8.1B

A3

A3

O

O

16'-6" 6'-1" 6'-11"

1' -8

OAE501

A3

'-4

'-0

1' -6

OAE501

C2

042000.D03

034500.A10

7 7OAE501

C1

5' -3

1'

-9

13'-0" 2'-3"

'-8

1'

-7

4' -4

3'

-4

M6

O102.1

O

2.

SHOP ANNEX

ENTRY

O101

104400.A01 104400.A02

1'-6" 6"1'-6"

FE FE FE FE

L3

104400.A01 104400.A02

6' -3

1'

-0

3" 3'-5"

FD

FD

FD

5'-3" 4'-4" 4'-8" 4'-4" 3'-3" 5'-11" 8'-4" 7"

4' -4

'-4

9' -4

076115.U02

FD

FD

OAE621

B2TYP

L1

L2

L7

A3

OAE311

A1

OAE312

A3

OAE312

A2

OAE312

OAE501

C4

OH

OAE532

B2

6" 11'-8" 3'-4"

1'-1" 2'-3" 4'-8" 3'-4" 1'-4"

102600.C05

055013.B01

N-A

N-B

N-3

W TLT

O104

M TLT

O103

O103

O104

220000.B05

O

A3D

A3D

B2

A3D

A3D B3D

A3E

OAE501

B4

B2D

SHOP ANNEX

ENTRY

O101

FE

104400.A01 104400.A02

220000.B06

FD

FD

N8C

M6

M6

M8

M8

A3

B3D

102600.C0511

220000.C02

220000.C02

1 HOUR FIRE BARRIER

PARTITION LEGEND

N-A

N-B

N-3

W TLT

O104

M TLT

O103

'-6

6"

'-6

O103

O104

O

7'-7" 7"

3'-4" 5'-8" 3'-0"

OPENING

8'-0"

1' -4

4'-3"

SHOP ANNEX

ENTRY

O101

5'-3" 4'-4"

FE

4'-3" 3'-4"

7"

12'-0"

7' -1

0" 8"

FD

FD

1' -2

/8

7'

-9

/4

3' -2

1'

-0

3/

4"

3' -2

1'-8"

1'-8"

1'-8" 2'-4 1/2"

6' -1

1"

N-E

N-1 N-5

N-F

N-3N-2 N-4

OAE201

C1

A1

OAE311

88'-5 1/4"

034500.A10

2' -6

/4

1'

-2

/4

'-9

/4

2'-9" 20'-7" 20'-7" 20'-7" 20'-7" 2'-9"

TY

P

1' -6

COVERED

AREA

L5 OAE502

A3

OAE502

C3

8'-3" 7" 1'-6"

L6

L6

A3

OAE523

A2

OAE311

089100.A01

076115.A01 089100.A01

076115.A01 8

3' -9

076115.U02

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

N

PLAN

NORTH

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:5

P

M

As indicated

O S

F

S H

O P

A N

N E

X

F

LO

O R

P

LA

N

G R

O U

N D

F

LO

O R

S

E C

T O

R B

OAE101B

EAD KJF BKH

12860136

1/8" = 1'-0"C2

FLOOR PLAN - GROUND FLOOR - SECTOR B

A

B

KEYPLAN

1/4" = 1'-0"C1

ENLARGED PLAN - TOILETS

MATERIAL NOTES

034500.A10 PRECAST CONCRETE INSULATED WALL PANEL

042000.D03 CMU 8"

055013.B01 STEEL BOLLARD

076115.A01 STANDING-SEAM METAL ROOF PANEL

076115.U02 DOWNSPOUT

089100.A01 EXTRUDED ALUMINUM WALL LOUVER

102600.C05 STAINLESS STEEL CORNER GUARD

104400.A01 FIRE EXTINGUISHER

104400.A02 FIRE EXTINGUISHER MOUNTING BRACKET

220000.B05 ELECTRIC WATER COOLER

220000.B06 EMERGENCY SHOWER/ EYE WASH COMBINATION UNIT

220000.C02 FLOOR DRAIN

1/4" = 1'-0" GRAPHIC SCALE

12'8'4'2'0 16'

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B DASHED LINES REPRESENT ITEMS ABOVE.

C ARCHITECTURAL EXTERIOR DIMENSIONS ARE TO EXTERIOR FACE OF INSULATED

PRECAST PANEL AND FACE OF METAL STUD, UNO.

D ARCHITECTURAL DIMENSIONS ARE TO COLUMN GRID, FACE OF MASONRY / CONCRETE,

FACE OF METAL STUD, UNO.

E REFER TO SHEET OGC001 FOR CODE SUMMARY AND OGC101 FOR LIFE SAFETY PLAN.

F REFER TO SHEET OAE101 FOR OVERALL ELEVATION AND BUILDING SECTION

REFERENCES.

G REFER TO SHEET OAE601 FOR DOOR SCHEDULE, DOOR/FRAME ELEVATIONS,

TRANSLUCENT PANEL ELEVATIONS, AND LOUVER ELEVATIONS.

H REFER TO SHEETS OAE621-OAE622 FOR DOOR DETAILS AND SHEET OAE631 FOR LOUVER

AND TRANSLUCENT PANEL DETAILS.

I EXTERIOR WALL FURRING TO BE PARTITION TYPE B2, UNO. REFER TO SHEET OAE801

FOR PARTITION TYPES.

J PARTITIONS TO BE M8, UNO. REFER TO SHEET OAE801 FOR PARTITION TYPES.

K REFER TO SHEET OAE821 FOR THROUGH PENETRATION FIRESTOP SYSTEM SCHEDULE.

L REFER TO SHEET OAF601 FOR FINISH SCHEDULES AND FINISH IDENTIFICATION

SCHEDULES.

M PLUMBING FIXTURES SHOWN FOR REFERENCE ONLY. REFER TO PLUMBING SHEETS FOR

MORE INFORMATION.

N SPECIALTY EQUIPMENT SHOWN FOR REFERENCE ONLY. REFER TO SHEET OQJ101B FOR

EQUIPMENT PLAN AND OQJ201 FOR TYPICAL EQUIPMENT MOUNTING HEIGHTS AND

ELEVATIONS.

O REFER TO SHEET OQJ201 FOR TYPICAL TOILET ROOM MOUNTING HEIGHTS AND

ELEVATIONS.

1 CONCRETE-FILLED STEEL BOLLARD, IMPACT-RATED. REFER TO DETAIL C4/OAE561.

2 CONCRETE PAD FOR AIR COMPRESSOR. REFER TO SHEET OPP101B FOR ADDITIONAL

INFORMATION.

3 CONCRETE PAD FOR AHU. REFER TO SHEET OMH401 FOR ADDITIONAL INFORMATION.

4 DASHED LINE REPRESENTS ALUMINUM CANOPY ABOVE. REFER TO SHEET A3/OAE561

FOR ENLARGED CANOPY PLAN.

5 OVERHEAD DOOR CONTROL PANEL.

6 WATER HEATER AND EXTENSION TANK. REFER TO SHEET OPP101B FOR ADDITIONAL

INFORMATION. REFER TO SHEET OMH101B FOR WATER HEATER FLUE INFORMATION

AND C3/OAE541 FOR ROOF PENETRATION DETAIL.

7 CONDENSING UNIT AND CONCRETE PAD. REFER TO SHEET OMP101B FOR ADDITIONAL

INFORMATION.

8 STANDING SEAM METAL PANEL, VERTICAL INSTALLATION.

9 SERVICE SINK. REFER TO SHEET OPP101B FOR ADDITIONAL INFORMATION.

10 HOSE REEL, WALL-MOUNTED. REFER TO SHEETS OPP101B AND OPP502 FOR

ADDITIONAL INFORMATION.

11 REFER TO SHEET OAF601 FOR ADDITIONAL INFORMATION.

12 DASHED LINE REPRESENTS SOFFIT ABOVE.

13 REFER TO VOLUME 1, SHEET CG513 FOR DOWNSPOUT BOOT DETAILS.

OAE101B

1/4" = 1'-0"A1

ENLARGED DIMENSIONAL PLAN - TOILETS

1/8" = 1'-0"A2

FLOOR PLAN - COVERED AREA @ LOUVER

OAE101A

OAE101

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

S

S

S

S

S

S

S

N-E

N-1 N-5

N-A

N-B

N-C

N-F

N-3

N-D

N-2 N-4

OFFICE

O107

COMM

O106

JAN

O105

W TLT

O104

M TLT

O103

ELEC

O108

SHOP ANNEX

O102

OSF

O111

MECH

O109

076115.P03

1 1

N-D.1

4' -1

11"

083113.A01

095100.A01

107326.A02

5092900.B01092900.B01

1"

1' -0

076115.P03

076115.P03

3'-11" 3'-11"

7'-10"

5' -0

076115.P03

11'-9"

CEILING TYPES

CEILING LEGEND

INTERIOR: GYPSUM BOARD CEILING SYSTEM

EXTERIOR: CEMENT PLASTER CEILING SYSTEM

ACOUSTICAL CEILING TILE

2'-0" X 2'-0"

CEILING ACCESS PANEL.

MECHANICAL SYMBOLS

ELECTRICAL SYMBOLS

FIRE ALARM / SECURITY SYMBOLS

LIGHT

FIXTURES

EXIT LIGHTS

SPEAKER

OCCUPANCY SENSOR

SUPPLY AIR DIFFUSER

TRANSFER AIR REGISTER / GRILLE

RETURN AIR REGISTER / GRILLE

EXHAUST AIR REGISTER

SMOKE DETECTOR

FIRE ALARM

SPEAKER/STROBE WALL

MOUNTED

HEAT DETECTOR

COMMUNICATION SYMBOLS

REMOTE ACTUATOR

SPRINKLERS

METAL SOFFIT PANEL

NOTE:

NOT ALL ELEMENTS MAY BE USED.

FIRE ALARM SPEAKER

WALL MOUNTED

SMOKE DETECTOR

S

GAS DETECTOR

INTERIOR: GYPSUM BOARD CEILING SYSTEM -

MOISTURE RESISTANT

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

0 5'

3/32" = 1'-0" GRAPHIC SCALE

10' 20' 30' 40'

N

PLAN

NORTH

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:5

P

M

As indicated

O S

F

S H

O P

A N

N E

X

R E

F

LE

C T

E D

C E

IL

IN

G P

LA

N

G

R O

U N

D F

LO

O

R

O V

E R

A

LL

OAE111

EAD KJF BKH

12860137

3/32" = 1'-0"A2

GROUND FLOOR OVERALL REFLECTED CEILING PLAN

A

B

KEYPLAN

A REFER TO SHEETS OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B REFER TO SHEET OGC001 FOR CODE SUMMARY AND OGC101 FOR LIFE SAFETY PLAN.

C ALL CEILING HEIGHTS ARE ABOVE FINISHED FLOOR.

D ALL CEILINGS ARE 9'-0" AFF UNO.

E ALL CEILING GRIDS TO BE CENTERED IN ROOMS UNO.

F PROVIDE GLASS MAT FACED GYPSUM BOARD (092900.B01) AT TOILET ROOM CEILINGS,

TYPICAL.

G ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT CEILING FINISH UNO.

H SINGLE LIGHT FIXTURES IN GYPSUM BOARD CEILINGS TO BE CENTERED IN BOTH

DIRECTIONS UNO.

I REFER TO SHEET OAF601 FOR FINISH SCHEDULE AND FINISH IDENTIFICATION.

J REFER TO MECHANICAL DRAWINGS OMH101A-OMH101B AND OMP101A-OMP101B FOR

COORDINATION OF ALL MECHANICAL ITEMS SHOWN IN CEILING PLAN.

K REFER TO ELECTRICAL DRAWINGS OFX101, OEL101A-OEL101B, AND OET101B FOR

COORDINATION OF ALL ELECTRICAL ITEMS SHOWN IN CEILING PLAN.

L COMMUNICATION DEVICES AND CEILING MOUNTED EQUIPMENT TO BE CENTERED IN

CEILING TILE UNO.

M IN CASE OF DISCREPANCIES IN LOCATION OF COMPONENTS WITH ELECTRICAL

DRAWINGS, THE REFLECTED CEILING PLAN SHALL GOVERN.

1 EXPOSED STRUCTURE ABOVE.

2 CABLE TRAY. REFER TO SHEETS OTT101 AND OTT101B FOR ADDITIONAL INFORMATION.

3 CEILING ACCESS DOOR, 12"x12". REFER TO DETAIL B2/OAE561.

4 RADIANT HEATER. REFER TO SHEETS OMH101A AND OMP101A FOR ADDITIONAL

INFORMATION.

5 EXTRUDED ALUMINUM CANOPY SYSTEM, CENTER ON DOOR. REFER TO SHEET OAE561

FOR ADDITIONAL INFORMATION.

MATERIAL NOTES

076115.P03 METAL SOFFIT PANEL SYSTEM

083113.A01 ACCESS DOOR

092900.B01 GYPSUM BOARD, GLASS MAT FACED 5/8"

095100.A01 ACOUSTICAL CEILING UNITS

107326.A02 DOOR CANOPY SYSTEM

OAE301

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

N-EN-A N-B N-C N-F

B1

OAE301

N-D

A3

OAE301 034500.A10

034500.A10

225226227

229230

232233234235

239.1

A4

OAE313

A1

OAE301

083323.A02

081113.A04

089100.A01

HM-1

PC-1

HM-1

OCD-1

PC-2

HM-1

MP-1

HM-1

PT-1

MP-1

L2

L1

N-D.1

T.O. STL

16'-5 1/2"

T.O. CMU

24'-8"

076115.U02

'-0

034500.A03

PC-1

1 PT-1

107326.A02

034500.A10

PC-1

081113.A04

HM-1

MP-1

10'-0"

3'-4 1/2"

076115.A019

'-0

076115.A01

MP-1

083323.A02

PC-2

076115.A01 9

L6

076115.H07

MP-1

089100.A01

076115.A01

MP-1

240.1

GROUND FLR

0'-0"

N-1N-5

D1

OAE301

N-3 N-2N-4

081113.A04

221222223223223223224 239240239240239

076115.A01

317 1715

323130.A03

FNC-1

HM-1

MP-1

PT-1

T.O. STL

16'-5 1/2"

T.O. CMU

24'-8"

076115.U02

HM-1

076115.A01

MP-1

034500.A10

PC-1

076115.H01

MP-1

17 1717

PT-1

PT-1

PT-1 PT-1 PT-1

GROUND FLR

0'-0"

N-1N-5

D1

OAE301

N-3 N-2N-4

'-1

1/

2"

089100.A01

076115.P03

034500.A10

221222223223223223224

L5

6 6076115.A01

034500.A10

081113.A04

PC-1

MP-1

HM-1

PC-2

HM-1

MP-1

T.O. STL

16'-5 1/2"

OAE523

A3

OAE523

A3OPH

15 15

076115.P03 052100.A02

104400.B0116

EXTERIOR FINISH LEGEND

ARCHITECTURAL PRECAST CONCRETE

SANDBLAST MEDIUM - PCI 110

ARCHITECTURAL PRECAST CONCRETE

SANDBLAST LIGHT - PCI 110

STANDING SEAM METAL PANEL

KINGSPAN SLR DARK BRONZE

TP-1 TRANSLUCENT PANEL

KINGSPAN ICE WHITE

ADDITIONAL FINISHES:

MP-1

PC-2

PC-1

HM-1 HM DOOR / HM DOOR FRAME / DOWNSPOUTS / LOUVERS

/ LOUVER FRAME

SW 6072 VERSATILE GRAY

MP-1 SOFFIT PANEL / VERTICAL METAL PANEL / CANOPY

KINGSPAN SLR DARK BRONZE

FNC-1 EXTERIOR METAL FENCE

RAL 7044

PT-1 EXTERIOR BOLLARDS / EXTERIOR GAS METER

SW 6072 VERSATILE GRAY

TPF-1 TRANSLUCENT PANEL FRAME

KINGSPAN BONE WHITE

OCD-1 OVERHEAD COILING DOOR

RAL 7044

ST-1 STUCCO

STUCCO TO MATCH SW 6072 VERSATILE GRAY

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

SHEET NOTES:

NOTES:

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:0

P

M

1/8" = 1'-0"

O S

F

S H

O P

A N

N E

X

B U

IL

D

IN

G

E

LE

V A

T

IO

N S

OAE201

EAD KJF BKH

12860138

1/8" = 1'-0"A1

EAST ELEVATION

1/8" = 1'-0"B1

NORTH ELEVATION

MATERIAL NOTES

034500.A03 PRECAST CONCRETE WALL PANEL

034500.A10 PRECAST CONCRETE INSULATED WALL PANEL

052100.A02 OPEN WEB STEEL JOIST

076115.A01 STANDING-SEAM METAL ROOF PANEL

076115.H01 METAL FLASHING

076115.H07 RAKE FLASHING

076115.P03 METAL SOFFIT PANEL SYSTEM

076115.U02 DOWNSPOUT

081113.A04 STEEL DOOR, INSULATED

083323.A02 INSULATED OVERHEAD COILING DOOR

089100.A01 EXTRUDED ALUMINUM WALL LOUVER

104400.B01 FIRE EXTINGUISHER CABINET

107326.A02 DOOR CANOPY SYSTEM

323130.A03 DECORATIVE METAL FENCE

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".

REFER TO CIVIL PLANS FOR SLAB ELEVATIONS RELATIVE TO NORTH AMERICAN

VERTICAL DATUM (NAVD) SYSTEM.

C STANDING SEAM METAL ROOF TO BE 1" PER FOOT MINIMUM.

D 00 SYMBOL DENOTES PRECAST PANEL NUMBER. REFER TO SHEET OAE221 FOR

PRECAST PANEL KEY PLAN AND SHEETS OAE222-OAE226 FOR PRECAST PANEL

ELEVATIONS.

E WHERE COLOR IS SHOWN AS BEING SPECIFIC TO ONE MANUFACTURER, AN EQUIVALENT

COLOR BY ANOTHER MANUFACTURER MAY BE SUBMITTED FOR APPROVAL.

MANUFACTURERS AND MATERIALS SPECIFIED ARE NOT INTENDED TO LIMIT THE

SELECTION OF EQUAL COLORS FROM OTHER MANUFACTURERS.

F REFER TO SHEET OAE601 FOR TRANSLUCENT PANEL ELEVATIONS AND LOUVER

ELEVATIONS.

G COORDINATE ALL EXTERIOR EQUIPMENT WITH ENGINEERING DRAWINGS.

1 CONCRETE-FILLED STEEL BOLLARD, IMPACT-RATED. REFER TO DETAIL C3/OAE561.

2 DECORATIVE METAL FENCE. REFER TO SHEET OAS401-OAS402 FOR ADDITIONAL

INFORMATION.

3 PRECAST PANEL REVEAL, 3/4 INCH, TYPICAL. REFER TO SHEETS OAE531-OAE532

FOR TYPICAL PRECAST JOINT DETAILS.

4 PRECAST PANEL JOINT, 1 INCH, TYPICAL. REFER TO SHEETS OAE531-OAE532 FOR

TYPICAL PRECAST JOINT DETAILS.

5 LIGHTING FIXTURE. REFER TO SHEETS OEL101A-OEL101B AND OEL501-OEL701 FOR

ADDITIONAL INFORMATION.

6 RADIANT HEATER VENT. REFER TO SHEET OMH101A AND OMH502 FOR ADDITIONAL

INFORMATION. REFER TO C3/OAE541 FOR ROOF PENETRATION DETAIL.

7 WALL HYDRANT, ROUND COVER BOX, ENCASED, NON-FREEZE. REFER TO SHEET

OPP101A AND OPP502 FOR ADDITIONAL INFORMATION.

8 VTR. REFER TO SHEET OPP101A-OPP101B FOR ADDITIONAL INFORMATION. REFER

TO C3/OAE541 FOR ROOF PENETRATION DETAIL.

9 STANDING SEAM METAL PANEL, VERTICAL INSTALLATION.

10 EXTERIOR BUILDING SIGN. REFER TO SHEETS OAG101A-OAG101B AND C4/OAG502

FOR ADDITIONAL INFORMATION.

11 GAS METER/REGULATOR. REFER TO OPP101B FOR ADDITIONAL INFORMATION.

12 TURNED DOWN EDGE CONCRETE SIDEWALK. REFER TO VOLUME 1, SHEET CS104

FOR ADDITIONAL INFORMATION.

13 REFER TO VOLUME 1, SHEET CG513 FOR DOWNSPOUT BOOT DETAILS.

14 ROOM SIGNAGE, EXTERIOR. REFER TO SHEETS OAG101A-OAG101B AND OAG502

FOR ADDITIONAL INFORMATION.

15 ELECTRICAL OUTLET, DUPLEX. REFER TO SHEETS OEP101A-OEP101B FOR

ADDITIONAL INFORMATION.

16 FIRE EXTINGUISHER CABINET, SURFACE MOUNTED, ALL-WEATHER/OUTDOOR TYPE.

17 CONCRETE-FILLED STEEL BOLLARD, IMPACT-RATED. REFER TO DETAIL C4/OAE561.

1/8" = 1'-0"C1

NORTH ELEVATION - COVERED AREA

OAE101

OAE101A, OAE101B

OAE101

KEY NOTES 00

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

N-E N-AN-BN-CN-F B1

OAE301

N-D A3

OAE301

081113.A04034500.A10

209210211212213214215216217218219220239.1

A1

OAE301

SIM.

A4

OAE313

'-1

074213.P05

4 4

MP-1

PT-1

HM-1 FNC-1

107326.A02

042000.D03

042000.C04

PC-1

034500.A10

PC-2

076115.A01

MP-1 TP-1

TPF-1

MP-1

PC-1

ST-1

HM-1

L4T1 T1 T1 T1 T1 T1

9'-0" 3'-1" 9'-0" 10'-9"9'-0" 3'-1" 9'-0" 3'-1" 7'-7" 1'-5" 3'-1"9'-0" 3'-1" 9'-0" 10" 2'-3"

N-D.1

T.O. STL

16'-5 1/2"

T.O. CMU

24'-8"

076115.U02

L6

034500.A03

PC-1

076115.A01

MP-1

076115.H07

076115.A01

MP-1

076115.A01

MP-1

3MP-1

1" / 1'-0"

'-0

240.1

GROUND FLR

0'-0"

N-1 N-5D1

OAE301

N-3N-2 N-4

081113.A04034500.A10

034500.A10

042000.D03

201202203 204205206207208

076115.A01

076115.U02

042000.C04

14 089100.A01

PC-1ST-1

PC-1

HM-1

PC-1

MP-1

HM-1

076115.A01

HM-1

MP-1

MP-1 107326.A02

034500.A10

034500.A10

PC-2

PC-2

5' -0

L7

L3

T.O. STL

16'-5 1/2"

T.O. CMU

24'-8"

074213.A02

MP-1

MP-1

16'-7" 23'-7 1/2"

15'-0"

076115.A01

EXTERIOR FINISH LEGEND

ARCHITECTURAL PRECAST CONCRETE

SANDBLAST MEDIUM - PCI 110

ARCHITECTURAL PRECAST CONCRETE

SANDBLAST LIGHT - PCI 110

STANDING SEAM METAL PANEL

KINGSPAN SLR DARK BRONZE

TP-1 TRANSLUCENT PANEL

KINGSPAN ICE WHITE

ADDITIONAL FINISHES:

MP-1

PC-2

PC-1

HM-1 HM DOOR / HM DOOR FRAME / DOWNSPOUTS / LOUVERS

/ LOUVER FRAME

SW 6072 VERSATILE GRAY

MP-1 SOFFIT PANEL / VERTICAL METAL PANEL / CANOPY

KINGSPAN SLR DARK BRONZE

FNC-1 EXTERIOR METAL FENCE

RAL 7044

PT-1 EXTERIOR BOLLARDS / EXTERIOR GAS METER

SW 6072 VERSATILE GRAY

TPF-1 TRANSLUCENT PANEL FRAME

KINGSPAN BONE WHITE

OCD-1 OVERHEAD COILING DOOR

RAL 7044

ST-1 STUCCO

STUCCO TO MATCH SW 6072 VERSATILE GRAY

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

SHEET NOTES:

NOTES:

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:1

P

M

1/8" = 1'-0"

O S

F

S H

O P

A N

N E

X

B U

IL

D

IN

G

E

LE

V A

T

IO

N S

OAE202

EAD KJF BKH

12860139

1/8" = 1'-0"A1

WEST ELEVATION

1/8" = 1'-0"B1

SOUTH ELEVATION

MATERIAL NOTES

034500.A03 PRECAST CONCRETE WALL PANEL

034500.A10 PRECAST CONCRETE INSULATED WALL PANEL

042000.C04 PRECAST CONCRETE COPING

042000.D03 CMU 8"

074213.A02 INSULATED METAL WALL PANEL SYSTEM

074213.P05 TRANSLUCENT PANEL SYSTEM

076115.A01 STANDING-SEAM METAL ROOF PANEL

076115.H07 RAKE FLASHING

076115.U02 DOWNSPOUT

081113.A04 STEEL DOOR, INSULATED

089100.A01 EXTRUDED ALUMINUM WALL LOUVER

107326.A02 DOOR CANOPY SYSTEM

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B ARCHITECTURAL ELEVATION FOR GROUND FLOOR TOP OF SLAB IS DEFINED AS 0'-0".

REFER TO CIVIL PLANS FOR SLAB ELEVATIONS RELATIVE TO NORTH AMERICAN

VERTICAL DATUM (NAVD) SYSTEM.

C STANDING SEAM METAL ROOF TO BE 1" PER FOOT MINIMUM.

D 00 SYMBOL DENOTES PRECAST PANEL NUMBER. REFER TO SHEET OAE221 FOR

PRECAST PANEL KEY PLAN AND SHEETS OAE222-OAE226 FOR PRECAST PANEL

ELEVATIONS.

E WHERE COLOR IS SHOWN AS BEING SPECIFIC TO ONE MANUFACTURER, AN EQUIVALENT

COLOR BY ANOTHER MANUFACTURER MAY BE SUBMITTED FOR APPROVAL.

MANUFACTURERS AND MATERIALS SPECIFIED ARE NOT INTENDED TO LIMIT THE

SELECTION OF EQUAL COLORS FROM OTHER MANUFACTURERS.

F REFER TO SHEET OAE601 FOR TRANSLUCENT PANEL ELEVATIONS AND LOUVER

ELEVATIONS.

G COORDINATE ALL EXTERIOR EQUIPMENT WITH ENGINEERING DRAWINGS.

1 CONCRETE-FILLED STEEL BOLLARD, IMPACT-RATED. REFER TO DETAIL C4/OAE561.

2 PRECAST PANEL JOINT, 1 INCH, TYPICAL. REFER TO SHEETS OAE531-OAE532 FOR

TYPICAL PRECAST JOINT DETAILS.

3 STANDING SEAM METAL PANEL, VERTICAL INSTALLATION.

4 VTR. REFER TO SHEET OPP101A-OPP101B FOR ADDITIONAL INFORMATION. REFER

TO C3/OAE541 FOR ROOF PENETRATION DETAIL.

5 EXTRUDED ALUMINUM CANOPY SYSTEM, CENTER ON DOOR. REFER TO SHEET

OAE561 FOR ADDITIONAL INFORMATION.

6 EXTERIOR BUILDING SIGN. REFER TO SHEETS OAG101A-OAG101B AND C4/OAG502

FOR ADDITIONAL INFORMATION.

7 WALL HYDRANT, ROUND COVER BOX, ENCASED, NON-FREEZE. REFER TO SHEET

OPP101A AND OPP502 FOR ADDITIONAL INFORMATION.

8 SQUADRON LOGO BUILDING SIGN. REFER TO SHEETS OAG101B AND A2/OAG502

FOR ADDITIONAL INFORMATION.

9 LIGHTING FIXTURE. REFER TO OEL101A FOR ADDITIONAL INFORMATION.

OAE101

OAE101

KEY NOTES 00

10 RADIANT HEATER VENT. REFER TO SHEET OMH101A AND OMH502 FOR

ADDITIONAL INFORMATION. REFER TO C3/OAE541 FOR ROOF PENETRATION

DETAIL.

11 CONCRETE PAVEMENT, 8" THICK, OVER 8" (MIN) AGGREGATE BASE COURSE.

REFER TO VOLUME 1, SHEET CS104, FOR MORE INFORMATION.

12 ROOM SIGNAGE, EXTERIOR. REFER TO SHEETS OAG101A-OAG101B AND OAG502

FOR ADDITIONAL INFORMATION.

13 DISCONNECT SWITCH FOR CONDENSING UNIT. REFER TO SHEET OEP101B FOR

ADDITIONAL INFORMATION.

14 WALL HYDRANT, ROUND COVER BOX, ENCASED, NON-FREEZE. REFER TO SHEET

OPP101A AND OPP502 FOR ADDITIONAL INFORMATION.

15 CONCRETE RAMP WITH RAILINGS. REFER TO VOLUME 1, SHEET CS104 FOR

ADDITIONAL INFORMATION.

16 TURNED DOWN EDGE CONCRETE SIDEWALK. REFER TO VOLUME 1, SHEET CS104

FOR ADDITIONAL INFORMATION.

17 CONCRETE PAVEMENT, 8" THICK, OVER 8" (MIN) AGGREGATE BASE COURSE.

REFER TO VOLUME 1, SHEET CS501, FOR MORE INFORMATION.

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

N-E

N-A

N-B

N-C

N-F

N-3

N-D

N-2 N-4

OAE221

A1

P.

D

7' -1

0" 1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

'-0

1"

P.

D

3' -6

P.D.

12'-5" 1"

P.D.

12'-0" 1"

P.D.

12'-0" 1"

P.D.

12'-0" 1"

P.D.

12'-0" 1"

P.D.

12'-0" 1"

P.D.

12'-5"

P.D.

10'-6" 1"

P.D.

12'-0" 1"

P.D.

12'-0" 1"

P.D.

10'-11" 1"

P.D.

8'-0" 1"

P.D.

8'-11" 1"

P.D.

10'-6" 1"

P.D.

11'-11"

P.

D

'-7

1"

P.

D

7' -4

P.

D

'-8

P.

D

5' -3

1"

P.

D

4' -1

0"

1"

5' -2

P.

D

'-8

7'

-8

1"

P.

D

4' -1

0"

1"

P.

D

7' -5

P.

D

'-8

P.

D

7' -5

1"

P.

D

9' -2

1"

P.

D

'-0

1' -6

R .O

4' -4

1'

-6

1' -8

4'

-4

1' -8

1'

-7

R .O

4' -4

1'

-6

1'-6"

R.O.

8'-4" 2'-1"3'-1"

R.O.

4'-4" 1'-6"

2'-2"

R.O.

4'-4" 1'-6"

12'-0"

2' -8

R .O

4' -4

5'

-0

1' -9

R .O

4' -4

5'

-1 1"

2'-0"

R.O.

4'-4" 5'-8"

201202203204205206207208

221 222 223 223 223 223 224

034500.A10

034500.A10

034500.A10

034500.A10

N-D.1

2'-11"

R.O.

3'-3" 4'-4"

4' -1

/2

R .O

4' -3

1'

-7

/2

OAE532

C2 TYP

OAE532

B2

TYP

1' -6

9'

-9

'-2

'-0

'-4

'-0

1'-6" 20'-7" 20'-7" 20'-7" 20'-7" 1'-6"

N-1

N-F

N-2

P.

D

. R

TN

/2

1"

P.

D

. R

TN

/2

P.D.

2'-0"

TY

P

6"

P.

D

. R

TN

/2

1"

P.

D

. R

TN

/2

P.D.

2'-0"

239.1

239.1

2' -0

240.1 240.1

240.1

240.1

240.1

240.1

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

0 5'

3/32" = 1'-0" GRAPHIC SCALE

10' 20' 30' 40'

N

PLAN

NORTH

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:1

P

M

As indicated

O S

F

S H

O P

A N

N E

X

P R

E C

A S

T P

A N

E L

K E

Y P

LA

N

OAE221

EAD KJF BKH

12860140

3/32" = 1'-0"B2

PRECAST PANEL DIMENSIONAL PLAN - GROUND FLOOR

A

B

KEYPLAN

1/4" = 1'-0" A1

ENLARGED PLAN

MATERIAL NOTES

034500.A10 PRECAST CONCRETE INSULATED WALL PANEL

1 PRECAST PANEL ABOVE.

OAE221

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B 00 SYMBOL DENOTES PRECAST PANEL NUMBER. REFER TO SHEETS OAE222-OAE226

FOR PRECAST PANEL ELEVATIONS.

C PRECAST PANELS ARE BASED ON A 1" JOINT BETWEEN PANELS. PRECAST PANEL

REVEALS ARE BASED ON A 3/4" REVEAL.

D REFER TO SHEETS OAE531-OAE532 FOR TYPICAL PRECAST JOINT SEALANT,

REVEAL/JOINT DIMENSIONS, SEALANT WEEP DETAILS.

E COORDINATE DOOR, WINDOW AND OTHER OPENINGS WITH ARCHITECTURE AND

ENGINEERING DRAWINGS.

F THE NUMBER OF PANEL TYPES CAN BE REDUCED PER CONCRETE PANEL

MANUFACTURER RECOMMENDATIONS, WITH ARCHITECT'S APPROVAL.

G COORDINATE ALL DEVICES & OPENINGS ON PRECAST PANELS.

OAE201, OAE202

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

N-5

'-1

3' -8

8'

-4

2' -0

4' -1

'-0

11'-11"

2'-1"8'-4"1'-6"

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-4 10'-6"

'-1

4' -1

'-0

2' -0

4'-4"3'-3"2'-11"

6" 5'

-9

5' -9

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

'-1

8'-11"

1'-6"4'-4"3'-1"

4' -1

'-0

2' -0

3' -8

'-4

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

'-1

1'-6"4'-4"2'-2"

8'-0"

4' -1

'-0

2' -0

3' -8

'-4

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-3

'-1

10'-11"

2' -0

4'

-1

'-0

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

'-1

12'-0"

4' -1

'-0

2' -0

1'-5 1/4"2'-3"8'-3 3/4"

2' -3

9'

-9

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-2

'-1

12'-0"

4' -1

'-0

2' -0

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-1

'-1

10'-6"

2' -0

4'

-1

'-0

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-A

3'-6"

'-3

'-6

/2

2' -0

'-0

4' -6

/2

1' -1

1'

-1

1' -1

1" / 1'-0"

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

11'-0"

2' -0

'-5

/8

'-0

1' -1

5' -5

/8

" 1' -1

1'

-1

1' -1

'-6

/8

1" / 1'-0"

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-B 12'-0"

2' -0

'-5

/8

'-0

6'

-5

/8

'-5

/8

1' -1

"1 '-1

"1 '-1

"1 '-1

"1 '-1

1" / 1'-0"

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

12'-0"

1'-6" 9'-0" 1'-6"

'-5

/4

'-5

/4

1'

-1 "1

'-1 "1

'-1

1' -1

1' -1

3'

-4 " 1'

-1 "1

'-1

2' -0

'-0

7' -5

/8

1" / 1'-0"

T.O. FOOTING

-2'-0"

EXTERIOR FINISH LEGEND

PC-2

PC-1

ARCHITECTURAL PRECAST CONCRETE

SANDBLAST MEDIUM - PCI 110

ARCHITECTURAL PRECAST CONCRETE

SANDBLAST LIGHT - PCI 110

T

ST

A

E OF F L OR IDA

R

EG ISTERED A R C H IT

E C T

B

IL

Y

K

EIT

H HO

L

LLOW

A Y

AR93022

ENGINEERS + SURVEYORS

KEY NOTES 00

SHEET NOTES:

NOTES:

1/4" = 1'-0" GRAPHIC SCALE

15'10'5'1'0

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

A

IR

C

R A

F T

M A

IN

T

E N

A N

C E

H A

N G

A R

V

O

LU

M E

O S

F O

P T

IO

N

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1363603

DRAWFORM REVISION: 25 AUGUST 2020

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

KTB / RLH

Approved by J. Scott Roberts, Asset Management Branch Head &

Supervisory Facility Planner, PWD

Beaufort, SC via email.

CGM

EJA

DSN

12/15/2022

A ut od es k D oc s:

//2

V

M F

A T

F

M ai nt en an ce

H an ga r/2

F

M ai nt H an ga r_ O

S F

S ho p A nn ex

.rv t

/3

/2

9:

:1

P

M

As indicated

O S

F

S H

O P

A N

N E

X

P R

E C

A S

T P

A N

E L

E

LE

V A

T

IO

N S

OAE222

EAD KJF BKH

12860141

1/4" = 1'-0"C1

1/4" = 1'-0"C2

1/4" = 1'-0" C3

1/4" = 1'-0"

C4

1/4" = 1'-0"B1

1/4" = 1'-0"B2

1/4" = 1'-0"B3

1/4" = 1'-0"B4

1/4" = 1'-0" A1

1/4" = 1'-0"

A2

1/4" = 1'-0"A3

1/4" = 1'-0"A4

OAE202, OAE221 OAE202, OAE221 OAE202, OAE221OAE202, OAE221

OAE202, OAE221OAE202, OAE221OAE202, OAE221OAE202, OAE221

OAE202, OAE221 OAE202, OAE221 OAE202, OAE221 OAE202, OAE221

A REFER TO SHEET OAE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B REFER TO SHEET OAE221 FOR PRECAST PANEL KEY PLAN.

C PANEL ELEVATIONS ARE MEANT TO BE A DESIGN GUIDE. PRECAST MANUFACTURER TO

VERIFY FINAL DIMENSIONS AND PRECAST PENETRATIONS PRIOR TO FABRICATION.

D PRECAST PANELS ARE BASED ON A 1" JOINT BETWEEN PANELS. PRECAST PANEL

REVEALS ARE BASED ON A 3/4" REVEAL.

E REFER TO SHEETS OAE531-OAE532 FOR TYPICAL PRECAST JOINT SEALANT,

REVEAL/JOINT DIMENSIONS, SEALANT WEEP DETAILS.

F COORDINATE DOOR, WINDOW AND OTHER OPENINGS WITH ARCHITECTURE AND

ENGINEERING DRAWINGS.

G COORDINATE BOTTOM OF PANEL WITH STRUCTURAL GRADE BEAM LOCATIONS.

H THE NUMBER OF PANEL TYPES CAN BE REDUCED PER CONCRETE PANEL

MANUFACTURER RECOMMENDATIONS, WITH ARCHITECT'S APPROVAL.

I COORDINATE ALL DEVICES & OPENINGS ON PRECAST PANELS.

1 COORDINATE UTILITY OPENING AND PENETRATIONS IN PRECAST, TYPICAL. REFER TO

ELECTRICAL, MECHANICAL, AND PLUMBING DRAWINGS FOR MORE INFORMATION

2 ROUGH OPENING FOR DOOR.

3 PRECAST PANEL JOINT, 1 INCH, TYPICAL. REFER TO SHEETS OAE531-OAE532 FOR

TYPICAL PRECAST JOINT DETAILS.

4 ROUGH OPENING FOR TRANSLUCENT PANEL.

M

O D

P

/2

M

O D

P

A N

D M

O D

P

/2

12'-0"

2'-8" 4'-4" 5'-0"

1'-6" 9'-0" 1'-6"

3' -4

1'

-1

2' -0

'-0

1' -1

"1 '-1

"1 '-1

"1 '-1

"1 '-1

"1 '-1

"1 '-1

1" / 1'-0"

'-5

/4

8' -5

/4

'-5

/4

3'

-0

/4

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-C

1'-9" 4'-4"

5'-11"

12'-0"

1' -1

"1 '-1

"1 '-1

1'

-1 "1

'-1 "1

'-1 "1

'-1 "1

'-1

1' -1

"1 '-1

'-0

2'

-0

3' -2

1'

-2

3' -8

8'

-4

1" / 1'-0"

'-6

/8

'-6

/8

'-6

/8

7' -2

/8

1'-6" 9'-0" 1'-6"

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

12'-0"

1'-6" 9'-0" 1'-6"

'-6

/8

1' -1

"1 '-1

"1 '-1

1'

-1 "1

'-1 "1

'-1 "1

'-1

1' -1

"1 '-1

3' -4

1'

-1

'-0

1" / 1'-0"

6' -1

/3

2" 2'

-0

'-6

/8

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

12'-0"

1'-6" 9'-0" 1'-6"

1' -1

"1 '-1

"1 '-1

1'

-1 "1

'-1 "1

'-1

1' -1

"1 '-1

3' -4

1'

-1

'-0

1" / 1'-0"

2' -0

'-6

5' -1

'-6

T.O. FOOTING

-2'-0"

GROUND FLR

0'-0"

N-D 12'-0"

1'-6" 9'-0" 1'-6"

1' -1

"1 '-1

"1 '-1

1'

-1 "1

'-1 "1

'-1

1' -1

"1 '-1

3' -3

1'

-2

'-0

1" / 1'-0"

2' -0

'-5

/8

4' -0

/8

'-…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .