Attachment K - VOL3_1363603dwg11of11.pdf
PDF 2 MB Posted
- Attached to
- P475 Aircraft Maintenance Hangar
- Solicitation number
- N4008526R0148
About this file
These telecommunication design documents are for the P-475 Aircraft Maintenance Hangar project at MCAS Beaufort, South Carolina, specifically for the Optional Shop Facility (OSF) portion. The documents detail the telecommunications infrastructure, including grounding systems, cable management, equipment racks, and outlet configurations. Key technical specifications include:
The design includes a communications room (O106) with a 45RU equipment rack featuring 48-port patch panels, switches, vertical and horizontal cable management, and a 2KVA UPS. The telecommunications system will have 64 total cables, with outlets distributed across standard, modular furniture, wall phone, and TV locations. Grounding will follow TIA-607-D standards, with primary bonding busbars, conduit bonding, and specific conductor sizing for various connections. The project is part of a naval facilities engineering systems command contract, with work to be performed only if the OSF option is awarded, and modifications noted for May 2023 and October 2025.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
A AMPERES
AFC
AFF
HV
AFG
INC
AIC
JB
ATS
KAIC
AWG
KV
BFC
KVA
BFG
KVAR
C
KW
CAB
KWH
CATV
LAN
CCTV
LED
CKT
LTG
CL
m
CLG
mm
CT's
MAX
CU
MCB
DISC
MCC
DWG
MCP
EA
MFR
EF
MIN
EMT
MISC
EQUIP
MTR
EUH
MTD
EWC
MTS
EWH
N.C.
EXH
N.O.
EXIST
NA
FA
NC
FLUOR
NEC
GEN
NFPA
GFI
PNL
GFGI
PVC
GFP
REC
RGS
GND
TEL
HGT
TYP
HOA
UON
HP
V
VAV
W
G
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
HIGH VOLTAGE
ABOVE FINISHED GRADE
INCANDESCENT
AMPERES INTERRUPTING CAPACITY
JUNCTION BOX
AUTOMATIC TRANSFER SWITCH
KILO-AMPERES INTERRUPTING
CAPACITY
AMERICAN WIRE GAUGE
KILO-VOLTS
BELOW FINISHED CEILING
KILO-VOLTS-AMPERES
BELOW FINISHED GRADE
KILO-VOLTS-AMPERES REACTIVE
CONDUIT
KILO-WATTS
CABINET
KILO-WATT-HOURS
CABLE TELEVISION
LOCAL AREA NETWORK
CLOSED CIRCUIT TELEVISION
LIGHT-EMITTING DIODE
CIRCUIT
LIGHTING
CENTERLINE
METER
CEILING
MILLIMETER
CURRENT TRANSFORMERS
MAXIMUM
COPPER
MAIN CIRCUIT BREAKER
DISCONNECT(ING)
MOTOR CONTROL CENTER
DRAWING(S)
MOTOR CIRCUIT PROTECTOR
EACH
MANUFACTURER
EXHAUST FAN
MINIMUM
ELECTRICAL METALLIC TUBING
MISCELLANEOUS
EQUIPMENT
MOTOR
ELECTRIC UNIT HEATER
MOUNTED
ELECTRIC WATER COOLER
MOUNTING
ELECTRIC WATER HEATER
MANUAL TRANSFER SWITCH
EXHAUST
NORMALLY CLOSED
EXISTING
NORMALLY OPEN
FIRE ALARM
NOT APPLICABLE
FLUORESCENT
NURSE CALL
GROUND
NATIONAL ELECTRICAL CODE
ENGINE GENERATOR SET
NATIONAL FIRE PROTECTION
ASSOCIATION
GROUND FAULT INTERRUPTER
GROUND FAULT CIRCUIT INTERRUPTER
PANEL
GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
POLYVINYL CHLORIDE
GROUND
RECEPTACLE
HEIGHT
RIGID GALVANIZED STEEL
HAND-OFF-AUTOMATIC
TELEPHONE
HORSEPOWER
TYPICAL
UNLESS OTHERWISE NOTED
VOLTS
GFCI
GROUND FAULT PROTECTION
WAP
VARIABLE AIR VOLUME UNIT
WP
WATTS
XFMR
WIRELESS ACCESS POINT
HVAC HEATING/VENTILATING / AIR
CONDITIONING
WEATHER PROOF
MTG
TRANSFORMER
AHU AIR HANDLING UNIT
CH CHILLER
UH UNIT HEATER
VA VOLT-AMPERES
SF SUPPLY FAN
HIT HEALTHCARE INFORMATION
TECHNOLOGY
GENERAL NOTES
A. SEE REFLECTED CEILING PLANS IN THE AE111 SERIES SHEETS FOR EXACT LOCATION OF
CEILING MOUNTED DEVICES.
B. INSTALL ALL EQUIPMENT AND DEVICES AT THE HEIGHT INDICATED. REFER TO ARCHITECTURAL
INTERIOR ELEVATIONS FOR SPECIAL MOUNTING HEIGHTS AND LOCATIONS OF ELECTRICAL AND
COMMUNICATIONS DEVICES. MOUNTING HEIGHTS AND LOCATIONS INDICATED ON
ARCHITECTURAL ELEVATIONS TAKE PRECEDENCE OVER OTHER MOUNTING HEIGHTS AND
LOCATIONS.
C. WHERE DEVICES ARE INDICATED TO BE MOUNTED ABOVE A COUNTERTOP, MOUNT DEVICE
SUCH THAT BOTTOM OF COVER PLATE IS 2" ABOVE TOP OF BACK SPLASH. IF THERE IS NO BACK
SPLASH, MOUNT DEVICE 2" ABOVE FINISHED COUNTER TOP SURFACE TO BOTTOM OF DEVICE
COVER PLATE.
D. ALL MATERIALS AND EQUIPMENT SHALL BE LISTED AS COMPLYING WITH THE APPLICABLE
STANDARDS OF UNDERWRITER'S LABORATORIES, INC OR OTHER APPROVED LISTING
AGENCIES.
E. VERIFY LOCATION OF ALL FLOOR-MOUNTED OUTLETS WITH CONTRACTING OFFICER PRIOR TO
ROUGH-IN.
F. WHERE CONDUIT IS ROUTED ABOVE THE FINISHED CEILING, COORDINATE LOCATION AND
ROUTING WITH OTHER TRADES AND SYSTEMS TO PROVIDE A COORDINATED INSTALLATION AND
TO ASSURE MAXIMUM ACCESSIBILITY TO ALL SYSTEMS. ALL JUNCTION BOXES AND PULL BOXES
SHALL REMAIN ACCESSIBLE.
G. DO NOT MOUNT COMMUNICATIONS DEVICES, OUTLETS, OR BOXES BACK TO BACK UNLESS
SPECIFICALLY INDICATED OTHERWISE. OFFSET OUTLETS OR BOXES IN OPPOSITE SIDES OF
THE WALL BY AT LEAST 16".
H. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION FOR ALL TELEVISION AND MONITOR
OUTLETS WITH THE ARCHITECTURAL PLANS. THE EXACT LOCATION OF THESE OUTLETS SHALL
ALSO BE COORDINATED WITH THE SPECIFIC TELEVISION MOUNTING BRACKETS BEING
SUPPLIED FOR THIS PROJECT. THE OUTLETS SHALL BE CONCEALED FROM NORMAL VIEWING
ANGLES BY THE TELEVISION MONITOR.
I. MAINTAIN 12" CLEAR SPACE ABOVE ALL CABLE TRAYS. MAINTAIN AT LEAST 12" CLEAR SPACE
ON ONE SIDE OF ALL CABLE TRAYS FOR SIDE ACCESS TO THE CABLE TRAYS.
J. SEE A1/OTT501 FOR CONDUIT STUB-OUT TO CABLE TRAY DETAIL.
SYMBOL DESCRIPTION MOUNTING
MISCELLANEOUS
KEY NOTE SYMBOL. 00 NA
MOUNTINGSYMBOL DESCRIPTION
TELEPHONE/DATA SYSTEM
COMBINATION VOICE/DATA OUTLET. 18" AFF TO TOP
UON.
OC - MOUNT ABOVE COUNTER TOP
+48" - MOUNTING HEIGHT TO CENTER OTHER THAN 18" TO TOP
TELEPHONE OUTLET. 34" AFF TO
CENTER UON.
TELECOMMUNICATIONS BONDING BUSBAR. ABOVE LADDER
RACK
TELECOMMUNICATIONS EQUIPMENT RACK WITH HORIZONTAL
AND VERTICAL CABLE MANAGEMENT.
PLYWOOD TELEPHONE BACKBOARD.
FIRE RATED PATHWAY ASSEMBLY. FOUR INDIVIDUAL PATHWAYS
GANGED TOGETHER. SEE DETAIL A5/TT501.
LOW VOLTAGE LADDER RACK FOR COMMUNICATIONS SYSTEMS
WIRING ONLY. 4" HIGH x18" WIDE UON.
LOW VOLTAGE CABLE TRAY FOR COMMUNICATIONS SYSTEMS
WIRING ONLY. 4" HIGH x18" WIDE UON.
NUMBER OF PAIRS/FIBER STRANDS
CABLE TYPE:
FMM - FIBER OPTIC MULTI-MODE
FSM - FIBER OPTIC SINGLE MODE
C - COPPER
CABLE TERMINATION ROOM NUMBER
CABLE ORIGINATION ROOM NUMBER
BACKBONE CABLE IDENTIFICATION TAG:
------ / ------ - FMM.24
FLOOR
WALL
AS REQUIRED
SUSPENDED
SUSPENDED
PRIMARY BONDING BUSBAR. REFER TO C3/TT501 FOR
DETAIL
SUBSCRIPTS INDICATE THE FOLLOWING:
PBB -
SEE FACEPLATE CODES AND FACEPLATE DETAILS ON SHEET
OTT502 FOR OUTLET CONFIGURATIONS. MOUNTING HEIGHT
SUBSCRIPTS INDICATE THE FOLLOWING:
SEE FACEPLATE CODES AND FACEPLATE DETAILS ON SHEET
OTT502 FOR OUTLET CONFIGURATIONS.
TYPE 66 TERMINATION BLOCK. 60" AFF TO TOP.
PRIMARY BUILDING ENTRANCE PROTECTOR. 60" AFF TO TOP.
B E
P
SYMBOL DESCRIPTION MOUNTING
PUBLIC ADDRESS SYSTEM
SPEAKER. SUBSCRIPTS INDICATE PAGING ZONE AND VOLUME
CONTROL
V-H01 C01
S PENDANT
PAEC
PUBLIC ADDRESS SYSTEM EQUIPMENT TERMINAL CABINET WITH
ZONE AMPLIFIERS. CABINET SHALL BE HINGED TO ALLOW
ACCESS TO THE BACK OF CABINET MOUNTED EQUIPMENT.
6'-0" TO TOP
DONALD R SELLERS
REG. NO. 110645
EXPIRES 12−31−2028 RR
ENGI
S
E D
N
OI
T
UBI
RTSIDSNOITACINUMM
O
C D
E R
E T
SI
GE
DDCR
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
O S
F O
P T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
O S
F s ho p
A nn ex L
V -R
V T
.rv t
/6
/2
4:
:1
P
M
As indicated
T E
LE
C
O M
M U
N
IC
A T
IO
N
S L
E G
E N
D A
N D
A B
B R
E V
IA
T
IO
N
S
OTG001
DRS KGG KLM
12860251
INCLUDE THIS WORK ONLY IF
OSF OPTION IS AWARDED.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
N-E
N-1 N-5
N-A
N-B
N-C
N-F
N-3
N-D
N-2 N-4
SHOP ANNEX
O102
OSF
O111
OFFICE
O107
COMM
O106
JAN
O105
W TLT
O104
M TLT
O103 SHOP ANNEX ENTRY
O101 ELEC
O108
MECH
O109
12"x4"
8"x4"
8"x4"
8"x4"
8"x4"
DONALD R SELLERS
REG. NO. 110645
EXPIRES 12−31−2028 RR
ENGI
S
E D
N
OI
T
UBI
RTSIDSNOITACINUMM
O
C D
E R
E T
SI
GE
DDCR
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
O S
F O
P T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
O S
F s ho p
A nn ex L
V -R
V T
.rv t
/6
/2
4:
:2
P
M
1/16" = 1'-0"
O S
F
S H
O P
A N
N E
X
F L
O O
R P
LA
N
O
V E
R A
L L
T
E L
E C
O M
M U
N
IC
A T
IO
N
S
OTT101
DRS KGG KLM
12860252
A
B
KEYPLAN
1/16" = 1'-0" A2
OSF - FLOOR PLAN - GROUND FLOOR - OVERALL - TELECOMMUNICATIONS
1 MOUNT CABLE TRAY IN THIS ROOM AT 12'-0" ABOVE FINISHED FLOOR TO
BOTTOM.
2 (4) 4", 1 HOUR FIRE RATED WALL PENETRATION ASSEMBLIES.
A. PROVIDE A MINIMUM OF 12" CLEARANCE ABOVE AND 12" ON AT LEAST ONE
SIDE OF ALL CABLE TRAYS.
B. PROVIDE EXTERIOR EXPOSURE CORROSION PROTECTION AND CONTROL
IN ACCORDANCE WITH AN ENVIRONMENTAL SEVERITY CLASSIFICATION
(ESC) OF C4 FOR BUILDING SYSTEMS AND COMPONENTS IN THE
FOLLOWING ROOMS: O101 SHOP ANNEX ENTRY, O102 SHOP ANNEX, O108
ELEC, O109 MECH, AND O111 OSF.
INCLUDE THIS WORK ONLY IF
OSF OPTION IS AWARDED.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
N-E
N-1 N-5
N-C
N-F
N-3
N-D
N-2 N-4
O111
OSF
DONALD R SELLERS
REG. NO. 110645
EXPIRES 12−31−2028 RR
ENGI
S
E D
N
OI
T
UBI
RTSIDSNOITACINUMM
O
C D
E R
E T
SI
GE
DDCR
ENGINEERS + SURVEYORS
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
O S
F O
P T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
O S
F s ho p
A nn ex L
V -R
V T
.rv t
/6
/2
4:
:3
P
M
1/8" = 1'-0"
O S
F
S H
O P
A N
N E
X
F L
O O
R P
LA
N
S
E C
T O
R A
T
E L
E C
O M
M U
N
IC
A T
IO
N
S
OTT101A
DRS KGG KLM
12860253
A
B
KEYPLAN
1/8" = 1'-0" A2
OSF - FLOOR PLAN - GROUND FLOOR - SECTOR A - TELECOMMUNICATIONS
A. SHEET SHOWN FOR REFERENCE ONLY.
INCLUDE THIS WORK ONLY IF
OSF OPTION IS AWARDED.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
S
S
S
S
S
S
S
N-1 N-5
N-A
N-B
N-C
N-3N-2 N-4
O102
SHOP ANNEX
O107
OFFICE
O106
COMM
O105
JAN
O104
W TLT
O103
M TLT
O101
SHOP ANNEX
ENTRY
O108
ELEC
O109
MECH
OTT101B
A2
+48" +48" +48" +48" +48" +48" +48"+48"
+48" +48"
+48"
+48"
W W
W
Z11 Z11 Z11
Z11Z11Z11
Z11
N-A
N-B
N-2
FRONT
PBB-OSF
PAER
W
N-A
N-B
N-2
DONALD R SELLERS
REG. NO. 110645
EXPIRES 12−31−2028 RR
ENGI
S
E D
N
OI
T
UBI
RTSIDSNOITACINUMM
O
C D
E R
E T
SI
GE
DDCR
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
1/4" = 1'-0" GRAPHIC SCALE
15'10'5'1'0
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
O S
F O
P T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
O S
F s ho p
A nn ex L
V -R
V T
.rv t
/6
/2
4:
:4
P
M
As indicated
O S
F
S H
O P
A N
N E
X
F L
O O
R P
LA
N
S
E C
T O
R B
T
E L
E C
O M
M U
N
IC
A T
IO
N
S
OTT101B
DRS KGG KLM
12860254
A
B
KEYPLAN
1/8" = 1'-0"B2
OSF - FLOOR PLAN - GROUND FLOOR - SECTOR B - TELECOMMUNICATIONS
1/4" = 1'-0"A2
ENLARGED COMMUNICATIONS ROOM O106
FLOOR PLAN LADDER RACK PLAN
1 100% VOID FREE, FIRE RATED, 3/4" PLYWOOD BACKBOARD FROM FINISHED
FLOOR TO 8'-0" AFF. PAINT ALL SIDES AND EDGES WITH TWO COATS OF
FIRE RETARDANT PAINT. DO NOT PAINT OVER FIRE RATING LABEL.
TYPICAL FOR ALL WALLS.
2 19" WIDE X 7' TALL TWO POST RACK, TYPICAL.
3 WALL SUPPORTED 12” WIDE LADDER RACK CABLE RUNWAY. PROVIDE
TRIANGULAR WALL STEEL SUPPORT BRACKETS AS REQUIRED. MOUNT
LADDER RACK SYSTEM AT 6” ABOVE THE TOP OF THE EQUIPMENT RACKS.
4 (4) 4", 1 HOUR FIRE RATED WALL PENETRATION ASSEMBLIES.
5 (2) 4" CONDUITS, SEE SHEET TS105 FOR CONTINUATION.
6 MOUNT PBB AT 12" ABOVE LADDER RACK TO CENTER.
7 WALL SPACE FOR OSP COPPER CABLE TERMINATIONS AND BUILDING
ENTRANCE PROTECTORS.
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
INCLUDE THIS WORK ONLY IF
OSF OPTION IS AWARDED.
A. PROVIDE EXTERIOR EXPOSURE CORROSION PROTECTION AND CONTROL
IN ACCORDANCE WITH AN ENVIRONMENTAL SEVERITY CLASSIFICATION
(ESC) OF C4 FOR BUILDING SYSTEMS AND COMPONENTS IN THE
FOLLOWING ROOMS: O101 SHOP ANNEX ENTRY, O102 SHOP ANNEX, O108
ELEC, O109 MECH, AND O111 OSF.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
TOP VIEW
FRONT VIEW
SEE A1/OTT601 FOR
CONNECTIONS
HUB GROUND CLAMP (TYPICAL)
STANDOFF
INSULATOR
(TYPICAL)
304 STAINLESS
STEEL BRACKET, 1/8"
THICK (TYPICAL)
TWO HOLE
LUG
ENGRAVED LAMINATED PLASTIC TAG WITH GREEN
FACE AND WHITE LETTERS TO IDENTIFY THE
DESTINATION OF EACH GROUNDING CONDUCTOR.
FASTEN TO GROUNDING ELECTRODE CONDUCTOR
WITH ZIP TIE (TYPICAL).
2"1/ 4"
4"
1'-6"
2'-5"
CONDUIT FITTING AS
REQUIRED (TYPICAL)
COPPER GROUND BUS WITH
PRE-DRILLED HOLES AS
REQUIRED.
BICSI PATTERN COPPER GROUND BUS.
FASTEN TO STRUCTURE
HEX NUT AND WASHER
1 5/8" SQUARE
STEEL CHANNEL
FINISHED CEILING
CABLE TRAY FASTENED
TO STEEL CHANNEL
CABLE TRAY GROUND CLAMP
TYPICAL CONDUIT STUB-OUT
ABOVE CABLE TRAY. EXTEND
CONDUIT TO WITHIN 6" OF
CABLE TRAY
FASTEN TO STRUCTURE
HEX NUT AND WASHER
#6 AWG COPPER GROUND
INSULATED BUSHING
THREADED ROD, TYPICAL FASTEN TO STRUCTURE
HEX NUT AND WASHER1 5/8" SQUARE STEEL
CHANNEL
LADDER RACK RAIL
LADDER RACK RUNG WALL STUDS GYPSUM WALL
BOARD
CABLES TO CABLE TRAY
SECTION THROUGH WALL
FIRE/SMOKE RATED
PATHWAY
A. SEE PARTITION TYPES, SHEET AE801 FOR PATHWAY REQUIREMENTS.
B. CROSS SECTIONAL AREA OF PATHWAY SHALL BE EQUAL TO OR GREATER THAN
CROSS SECTIONAL AREA OF ASSOCIATED CABLE TRAY.
NOTES:
#10 AWG INSULATED
COPPER CONDUCTOR.
BOND TO NEAREST
CABLE TRAY.
#10 AWG INSULATED
COPPER CONDUCTOR.
BOND TO NEAREST CABLE
TRAY.
DONALD R SELLERS
REG. NO. 110645
EXPIRES 12−31−2028 RR
ENGI
S
E D
N
OI
T
UBI
RTSIDSNOITACINUMM
O
C D
E R
E T
SI
GE
DDCR
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
O S
F O
P T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
O S
F s ho p
A nn ex L
V -R
V T
.rv t
/6
/2
4:
:5
P
M
As indicated
T E
LE
C
O M
M U
N
IC
A T
IO
N
S D
E T
A
IL
S
OTT501
DRS KGG KLM
12860255
NOT TO SCALEC2
PRIMARY BONDING BUSBAR (PBB) DETAIL
NOT TO SCALE
A1
CONDUIT STUB-OUT DETAIL - BASKET TRAY
NOT TO SCALE
A2
LADDER RACK TRAPEZE SUPPORT DETAIL
NOT TO SCALE
A4
FIRE RATED PATHWAY DETAIL
INCLUDE THIS WORK ONLY IF
OSF OPTION IS AWARDED.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
DETAIL NOTES:
A. ALL BACK BOXES SHALL BE 4 11/16" BY 2 7/8" DEEP WITH SINGLE GANG PLASTER RING UNLESS OTHERWISE
INDICATED.
B. PROVIDE BLANK INSERT FOR ALL UNUSED FACEPLATE PORTS.
C. PROVIDE (1) CATEGORY 6A, 4 PAIR HORIZONTAL CABLE FOR EACH 8 POSITION MODULAR JACK FROM THE
OUTLET TO HORIZONTAL PATCH PANEL IN THE INDICATED COMMUNICATIONS ROOM. SEE
TELECOMMUNICATIONS ZONE ALLOCATION PLAN FOR COMMUNICATIONS ROOM IN WHICH CABLES ARE
TERMINATED.
D. SEE A1/OTT501 FOR CONDUIT TO CABLE TRAY STUB OUT DETAIL.
1"C3/4"C
LBL
LBL
MFPWFP
8P
WS
WS
HCHC
STANDARD 4
PORT
WALL PHONE
FACE PLATE CODES
W SINGLE PORT FACE PLATE. WALL PHONE WITH ONE 8P JACK AND
MOUNTING STUDS
DETAIL CODES
1"C 1" CONDUIT TO NEAREST CABLE TRAY
3/4" CONDUIT TO NEAREST CABLE TRAY
BLANK INSERT
COAXIAL TELEVISION CABLE TO DIRECTIONAL COUPLER
HORIZONTAL CABLE(S)
MODULAR FACE PLATE
CATEGORY 6A CABLE TO NURSE CALL PATIENT STATION.
SEE 2/ET603 FOR ADDITIONAL REQUIREMENTS.
WALL PHONE FACE PLATE
WALL PHONE MOUNTING STUD
F-TYPE COAXIAL CONNECTOR
8P 8 POSITION MODULAR JACK
LABEL SPACE
3/4"C
B
CX
FC
HC
LBL
MFP
NC
WFP
WS
8P (WHITE)8P (WHITE)
8P (BLUE)8P (BLUE)
48-PORT PATCH PANEL AND 48-PORT
SWITCH CALCULATIONS
TOTAL 3 PORT DATA OUTLETS
TOTAL 1 PORT DATA OUTLETS
TOTAL TV OUTLETS
TOTAL NUMBER OF CABLES 64
OUTLET TYPE
OUTLET
QUANTITY
TOTAL
PORTS
NUMBER OF
CABLES
STANDARD OUTLET
MODULAR FURNITURE OUTLET
WALL PHONE OUTLET
TV OUTLET
TOTAL NUMBER OF CABLES 64
0 2 0
4 1 4
0 3 0
20 3 60
MF
TV
TOTAL NUMBER OF 48 PORT HORIZONTAL COPPER PATCH PANELS
TOTAL NUMBER OF 48 PORT SWITCHES
TOTAL FLOOR BOXES 0 6 0
ELEVATOR OUTLET 0 1 0
WEL
R1 R2
45RU
VR
45RU45RU V.6.CMV.10.CM V.10.CMV.6.CM
H.RGB
H.CM
H.CM
H.CM
H.CM
B.50.C
B.96.F
H.CM
SW.48
H.CM
H.BP
H.48.C
H.48.C
H.CM
B.50.C
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
P.UPS.2
H.RGB H.RGB
H.CM
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
H.BP
RACK ELEVATION EQUIPMENT CODES
CODE DESCRIPTION
B.96.F 96 PORT FIBER OPTIC PATCH PANEL WITH LC CONNECTORS FOR
BACKBONE CABLES
H.CM HORIZONTAL CABLE MANAGEMENT
V.6.CM DOUBLE SIDED 6" VERTICAL CABLE MANAGEMENT
45RU 7' HIGH, 45RU EQUIPMENT RACK
H.48.C CATEGORY 6A, 48 PORT HORIZONTAL COPPER PATCH PANEL
B.50.C 50 PAIR COPPER BACKBONE CABLE PATCH PANEL FOR BACKBONE CABLES
48 PORT SWITCH, GOVERNMENT FURNISHED, GOVERNMENT INSTALLEDSW.48
2KVA UPS, GOVERNMENT FURNISHED, GOVERNMENT INSTALLEDP.UPS.2
PATCH PANEL FORMULA
(TOTAL # OF CABLES)*1.25/48
SWITCH FORMULA
NUMBER OF PORTS PER PATCH PANEL
TOTAL TERMINATED CABLES PLUS 25%
TOTAL TERMINATED CAT6A HORIZONTAL CABLES IN
TELECOMMUNICATIONS ZONE
(((TOTAL # OF CABLES)*0.35))*1.3/48
NUMBER OF PORTS
PER SWITCH
TOTAL TERMINATED
CABLES PLUS 30%
TOTAL TERMINATED CAT6A HORIZONTAL CABLES IN
TELECOMMUNICATIONS ZONE
SWITCH PORT DIVERSITY FACTOR
H.RGB RACK MOUNTED GROUND BAR
H.BP BLANK FILLER PANEL
DONALD R SELLERS
REG. NO. 110645
EXPIRES 12−31−2028 RR
ENGI
S
E D
N
OI
T
UBI
RTSIDSNOITACINUMM
O
C D
E R
E T
SI
GE
DDCR
ENGINEERS + SURVEYORS
SHEET NOTES:
NOTES:
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
O S
F O
P T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
O S
F s ho p
A nn ex L
V -R
V T
.rv t
/6
/2
4:
:0
P
M
As indicated
T E
LE
C
O M
M U
N
IC
A T
IO
N
S D
E T
A
IL
S
OTT502
DRS KGG KLM
12860256
NOT TO SCALE
A1
TYPICAL VOICE / DATA OUTLET DETAILS
NOT TO SCALE
A3
O106 HIT RACK ELEVATION
NOT TO SCALEB4
RACK ELEVATION GENERAL NOTES
A. HIT RACKS SHALL ONLY BE USED TO TERMINATE HIT NETWORKING CABLE.
INCLUDE THIS WORK ONLY IF
OSF OPTION IS AWARDED.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
FIRST FLOOR
PBB-OSF
A. TELECOMMUNICATIONS GROUNDING SHALL BE IN ACCORDANCE WITH TIA-607-D.
B. INSTALL ALL TBC, TBB AND ALL BBC IN 1" CONDUIT, UNLESS OTHERWISE NOTED.
BOND CONDUIT TO GROUND BUS AS INDICATED IN DETAILS C2/TT501 AND
C4/TT501.
C. LABEL EACH GROUNDING AND BONDING CONDUCTOR AS REQUIRED BY TIA-607-D.
NOTES:
TBC TELECOMMUNICATIONS BONDING CONDUCTOR
BBC BACKBONE BONDING CONDUCTOR
TEBC TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR
TELECOMMUNICATIONS GROUNDING CONDUCTOR LEGEND
#6 TEBC TO LADDER RACK
#6 TEBC TO EACH EQUIPMENT
RACK
#4 TEBC TO STRUCTURAL STEEL
TYPICAL PBB/SBB CONNECTIONS
COMM ROOM
O106
#3/0 TBC TO MAIN ELECTRICAL
SERVICE GROUND
DONALD R SELLERS
REG. NO. 110645
EXPIRES 12−31−2028 RR
ENGI
S
E D
N
OI
T
UBI
RTSIDSNOITACINUMM
O
C D
E R
E T
SI
GE
DDCR
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
O S
F O
P T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
JAS
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/
F m ai nt
H an ga r_
O S
F s ho p
A nn ex L
V -R
V T
.rv t
/6
/2
4:
:2
P
M
NTS
T E
LE
C
O M
M U
N
IC
A T
IO
N
S R
IS
E
R S
D
IA
G R
A M
S
OTT601
DRS KGG KLM
12860257
NOT TO SCALE
A1
TELECOMMUNICATIONS GROUNDING RISER
INCLUDE THIS WORK ONLY IF
OSF OPTION IS AWARDED.
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
| OTG001 - TELECOMMUNICATIONS LEGEND AND ABBREVIATIONS |
| OTT101 - OSF / SHOP ANNEX - FLOOR PLAN - OVERALL - TELECOMMUNICATIONS |
| OTT101A - OSF / SHOP ANNEX - FLOOR PLAN - SECTOR A - TELECOMMUNICATIONS |
| OTT101B - OSF / SHOP ANNEX - FLOOR PLAN - SECTOR B - TELECOMMUNICATIONS |
| OTT501 - TELECOMMUNICATIONS DETAILS |
| OTT502 - TELECOMMUNICATIONS DETAILS |
| OTT601 - TELECOMMUNICATIONS RISERS DIAGRAMS |
| 2025-11-06T16:18:31-0500 | |
| Donald Sellers | |
| I am signing to certify the authenticity of this document. |
| 2025-11-06T16:19:07-0500 | |
| Donald Sellers | |
| I am signing to certify the authenticity of this document. |
| 2025-11-06T16:19:08-0500 | |
| Donald Sellers | |
| I am signing to certify the authenticity of this document. |
| 2025-11-06T16:19:08-0500 | |
| Donald Sellers | |
| I am signing to certify the authenticity of this document. |
| 2025-11-06T16:19:08-0500 | |
| Donald Sellers | |
| I am signing to certify the authenticity of this document. |
| 2025-11-06T16:19:08-0500 | |
| Donald Sellers | |
| I am signing to certify the authenticity of this document. |
| 2025-11-06T16:19:08-0500 | |
| Donald Sellers | |
| I am signing to certify the authenticity of this document. |
2025-11-22T15:56:27-0500
2025-11-22T15:56:54-0500
2025-11-22T15:56:28-0500
2025-11-22T15:56:28-0500
2025-11-22T15:56:28-0500
2025-11-22T15:56:28-0500
2025-11-22T15:56:29-0500
2025-11-22T15:56:29-0500
2025-11-22T15:56:54-0500
2025-11-22T15:56:55-0500
2025-11-22T15:56:55-0500
2025-11-22T15:56:55-0500
2025-11-22T15:56:56-0500
2025-11-22T15:56:56-0500
File details come from the government source that posted it. Updated .