N4008521B2504AsbestosSurveyReport.pdf

PDF 42 MB Posted

Attached to
Infrastructure Reset Demo Buildings - Package B Federal contract opportunity
Solicitation number
N4008521B2504
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document provides details on a federal solicitation and related asbestos survey report. The solicitation number is N4008521B2504 and concerns the demolition of various buildings at Naval Facilities Engineering Command according to provided plans and specifications. The Navy is seeking demolition services as described in the Infrastructure Reset Demo Buildings - Package B opportunity. The related asbestos survey report, with file name N4008521B2504AsbestosSurveyReport.pdf, contains information on any asbestos found in the buildings to be demolished. The response deadline and award date are not specified.

View the file

Other files for this federal contract opportunity

Other files attached to Infrastructure Reset Demo Buildings - Package B, newest first.
File Type Posted
N4008521B2504 Amendment08.pdf PDF
N4008521B2505 Amendment08.pdf PDF
N4008521B2504 Amendment07.pdf PDF
EMD Decision Memorandum.pdf PDF
N4008521B2504 Amendment06.pdf PDF
Building 40 Asbestos Survey.pdf PDF
Building 40 Lead Survey.pdf PDF
Building 40 Demo Plans.pdf PDF
Amended Section 02 82 16 Removal of Asbestos Materials.pdf PDF
N4008521B2504 Amendment05.pdf PDF
N4008521B2504 Amendment04.pdf PDF
N4008521B2504 Amendment03.pdf PDF
Contractor_Environmental_Guide.pdf PDF
N4008521B2504 Amendment02.pdf PDF
N4008521B2504 Amendment01.pdf PDF
N4008521B2504Dwgs.pdf PDF
N4008521B2504LeadSurveyReport.pdf PDF
N4008521B2504Solicitation.pdf PDF
N4008521B2504Specs.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos Survey FY20 Infrastructure Reset Demo Buildings

Marine Corps Base Camp Lejeune Project # 20-0001

Package B

Report Prepared By:

Christopher B. Walker The Walker Group Architecture, Inc

September 21st, 2020 WGA Project No. – 2001.IR20

Project Information

The Walker Group Architecture, Inc. was contracted by Camp Lejeune to conduct an asbestos sampling survey for Buildings/Structures: 3, 3B, 39, 113, 116, 117, 117A, 126, 214, 229, 300A, 307, 339, 425, 435, 436, 438, 524, 731, 738, 762, 812, 812A, 911, 1010, 1203, 1307, 1315, 1409, 1410, 1728, 1742, 1804, 1808, 2043, H48, PT6, SH13, SH22, SH39, SHE22 . Building 300 was also contracted for demolition and has previously been inspected for Lead and asbestos by WGA consultant Precision environmental. (See appendix B for survey). The specified buildings or structures are slated for demolition on board Marine Corps Base Camp Lejeune. An asbestos survey has been requested prior to disturbance of any potential asbestos containing materials

(ACM).

Scope of Services

A. The survey was performed on 01/24/18, 03/01/18, 03/06/18, 03/11/18, 04/19/18, 04/24/19, 05/02/19, 04/28/20, 05/13/20, 05/14/20, 05/20/20, 09/15/20 by Christopher B. Walker (NC Accredited Inspector #12878, expires January 31, 2021). The sampling was conducted in general accordance with the U.S. Environmental Protection Agency (EPA) requirements as defined in the asbestos Hazards Emergency Response Act (40 CFR Part 763) guidelines (AHERA) and in general accordance with the North Carolina Health Hazards Control Unit (NCHHCU).

B. The survey was conducted to identify the presence of asbestos containing materials (ACM) prior to repairs to the building.

C. The building was assessed to determine homogenous areas (groups of materials appearing to have been installed in the same general time period and uniform in color and texture).

D. As per AHERA, sufficient samples were collected from random locations of each homogenous area, with the number of samples based on the following criteria:

a. Thermal Insulation Materials (piping, breeching, boiler insulation, etc.) – A minimum of (3) samples are required. Patch areas (less than 6 square or liner feet) may have (2) sample collected.

b. Surfacing Materials (plaster, fireproofing, etc.) – A minimum of (7) samples are to be taken for areas greater than 5,000 square feet, five (5) samples for areas greater than 1,000 square feet, but less than 5,000 square feet, three

(3) samples for areas less than 1,000 square feet, two (2) samples for patching materials.

c. Miscellaneous Materials (flooring, adhesives, roofing, wallboard, etc.) – A minimum of (2) samples are required.

If any one sample of a material from a homogenous area is found to be positive, then that material is considered positive, regardless of results of other samples of that material, within that area.

Samples

A. The Walker Group Architecture collected suspect samples and shipped them to EMSL Analytical, Inc. (NVLAP Accredited Laboratory 102104-0) for PLM (polarized Light Microscopy) analysis. In an effort to reduce cost, the Walker Group instructed the laboratory to Stop Analysis at the first positive sample for each suspect material HGA and not to analyze the remaining samples from the same HGA.

Building 3

Findings

A. Building Description and Findings (Inspected 04-24-19)

Building 3 is an abandoned office building. The building exterior is brick and cmu.

Interior partitions are cmu and wood framed with gypsum board, and the roof is wood framed with asphalt shingles.

B. Laboratory Results

Material Material Type

Location Friability Laboratory Result Approx.Quantity

Window Caulk Misc Exterior NF Non-Detected N/A

Beige VCT (Floor tile) Misc Interior NF Non-Detected N/A Beige VCT (Mastic) Misc Interior NF Non-Detected N/A Beige VCT (Leveler) Misc Interior NF Non-Detected N/A

Rubber Base/ Mastic Misc Interior NF Non-Detected N/A 2X2 ACT Misc Interior Ceiling F Non-Detected N/A

Exterior Door Caulk Misc Exterior Doors NF Non-Detected N/A

Gypsum Board/Joint Compound Misc Interior Walls NF Non-Detected N/A

Asphalt Shingles/ Felt Misc Roof NF Non-Detected N/A

Carpet Mastic Misc Interior NF Non-Detected N/A

Residual Mastic at 2nd Floor Windows

Misc Exterior NF Non-Detected N/A

Plaster Ceiling Surf. Ceiling F Non-Detected N/A

Exterior Concrete Expansion Joint at Building Perimeter

Misc Exterior NF 5% Chrysotile 1250SF

Exterior Residual Caulk at Old Awning Location

Misc Exterior NF 8% Chrysotile 350SF

Based on the sample analysis, the following materials were found to be Asbestos Containing Materials.

Exterior Concrete Expansion Joint at Building Perimeter Exterior Residual Caulk at Old Awning Location

Materials found to contain asbestos in current inspection report and government provided inspection report should all be considered for the purpose of any demolition/renovation activities and disturbance.

ACM Materials found in previous government report in area of work:

-Pipe Insulation at 1st floor above ceilings – approx. 850LF -Mudded fittings at pipe insulation – approx. 100EA -Residual exterior caulking at new windows and doors – approx. 550LF -Exterior Caulking at doorways - approx. 50LF -Floor tile debris at 2nd floor sill plate – approx.2SF -Interior caulking at first floor center closet – approx. 24LF -Carpet adhesive – approx. 9500SF purpose of any demolition/renovation activities and disturbance.

Building 3B

A. Building Description and Findings (Inspected 05-14-19)

Building 3B is an abandoned office building. The building exterior is brick and cmu.

Interior partitions are cmu and wood framed with gypsum board, and the roof is wood

Material Materi al Type

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles/ Felt Misc Roof NF Non-Detected N/A

Exterior Door/ Window Caulk Misc Exterior NF Non-Detected N/A 12X12 Cream VCT (mastic) (Mechanical room only)

Misc Interior NF Non-Detected N/A

12X12 Cream VCT (Floor tile) Misc Interior NF Non-Detected N/A

12X12 Beige VCT (Floor tile) (Mechanical room only)

Misc Interior NF Non-Detected N/A

12X12 Beige VCT Mastic (Mechanical room only)

Misc Interior NF Non-Detected N/A

Gypsum Board/Joint Compound Misc Interior NF Non-Detected N/A

2X2 ACT Misc Interior NF Non-Detected N/A

Rubber Base/ Mastic Misc Interior NF Non-Detected N/A

Based on the sample analysis, none of the materials were found to be Asbestos Containing Materials.

Building 3C

C. Building Description and Findings (Inspected 05-14-19)

Building 3C is a mechanical building serving Building 3. The building exterior is brick and cmu. The roof construction is metal trusses, wood decking, and asphalt shingles.

D. Laboratory Results

Material Materi al Type

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles/ felt Misc Exterior NF Non-Detected N/A

Door Caulk Misc Interior NF Non-Detected N/A

Building 39

A. Building Description and Findings (Inspected 03-11-18)

Building 39 is a martial arts facility. The building exterior is vinyl siding and brick with a wood framed, asphalt shingle roof. The interior walls are gypsum board with a gypsum board ceiling.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles/Felt Misc Roof NF Non-Detected N/A

Roof Mastic at Exhaust Misc Roof NF 8% Chrysotile 2SF Cream 12x12 VCT/mastic Misc Floors NF <1% Chrysotile 487SF Beige 12x12 VCT Misc Floors NF Non-Detected N/A 12x12 VCT /mastic under stairs Misc Stairwell/Floor NF 5% Chrysotile 16SF Residual mastic from VCT Misc Floor NF 5% Chrysotile 660SF Gypsum/Joint Compound Misc Interior Walls F Non-Detected N/A Rubber Base/Mastic Misc Interior Wall NF Non-Detected N/A Fiberboard Misc Wall F Non-Detected N/A Textured ceilings in locker room Surface Ceiling F Non-Detected N/A

Roof Mastic at Exhaust Cream 12x12 VCT 12x12 VCT under stairs Residual mastic from VCT

Building 113

A. Building Description and Findings (Inspected 03-01-18)

Building 113 is a storage facility. The building exterior is brick masonry. The roof is wood framed with asphalt shingles. The interior walls are brick, covered in areas by gypsum board with a gypsum board ceiling.

Location Friability Laboratory Result Approx.Quantity

4” pipe insulation in attic TSI Attic F 5% Amosite 10% Chrysotile

360LF

Mudded fittings at 4” pipe Misc Attic F 30% Chrysotile 19EA

Asphalt shingles Misc Roof NF Non-Detected N/A Gypsum/Joint Compound Misc Walls F Non-Detected N/A Exterior window caulk Misc Exterior NF 2% Chrysotile 238LF

4” pipe insulation in attic Mudded fittings at 4” pipe

Exterior window caulk

Building 116

Building 116 is a storage facility. The building exterior is brick masonry. The roof is wood framed with asphalt shingles. The interior walls are brick covered in areas by gypsum board with a gypsum board ceiling.

Location Friability Laboratory Result Approx.Quantity

Gypsum/Joint compound Misc Walls F Non-Detected N/A

Rubber Base/Mastic Misc Floor/Wall NF Non-Detected N/A Exterior door/window caulk Misc Exterior Wall NF Non-Detected N/A Asphalt Shingles Misc Roof NF Non-Detected N/A

Based on the sample analysis, none of the materials were found to be Asbestos

Building 117

Building 117 is a storage facility. The building exterior is brick masonry. The roof is wood framed with asphalt shingles. The interior walls are wood stud and gypsum board with a gypsum board ceiling.

Location Friability Laboratory Result Approx.Quantity

Exterior caulk at reglet flashing Misc Exterior NF 8% Chrysotile 30LF

12x12 beige VCT Misc Floor NF Non-Detected N/A Gypsum/joint compound Misc Interior Wall/Ceiling F Non-Detected N/A Surface material on interior CMU at perimeter walls

Surface Walls F Non-Detected N/A

Water base/mastic Misc Floors NF Non-Detected N/A

Exterior caulk at reglet flashing

Building 117A

Building 117A is a storage facility. The building exterior is brick masonry. The roof is wood framed with asphalt shingles. A physical/ visual inspection revealed the following: No mechanical systems are in place.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles Misc Roof NF Non-Detected N/A Exterior door caulk Misc Exterior NF Non-Detected N/A

Caulk at mechanical penetration on wall Misc Wall NF Non-Detected N/A

Building 126

A. Building Description and Findings (Inspected 05-02-19)

Building 126 is an abandoned ammunitions building. The building exterior is brick.

Interior partitions are cmu and wood framed with gypsum board and the roof is wood

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles Misc. Exterior NF Non-Detected N/A

Exterior Door/Window Caulk Misc Exterior NF Non-Detected N/A Gypsum Board/Joint Compound Misc Interior NF Non-Detected N/A purpose of any demolition/renovation activities and disturbance.

ACM Materials found in previous government report in area of work:

- Roof Sealant at Southwest vent piping – approx. 4SF

Buiding 214

A. Building Description and Findings (Inspected 05-20-20)

Building 214 is an abandoned office building. The building exterior is brick with a wood framed/asphalt shingle roof system. Interior partitions are wood framed with gypsum board.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles/Felt Misc Roof NF Non-Detected N/A

Exterior Door/Window Caulk Misc Exterior NF Non-Detected N/A Gypsum Board/Joint Compound Misc Interior Walls NF Non-Detected N/A 12x12 Cream VCT/Mastic Misc Interior Floor NF Non-Detected N/A

12x12 White VCT/Mastic Misc Interior Floor NF Non-Detected N/A Plaster Walls Surf. Interior Ceiling F Non-Detected N/A 2x2 ACT Misc Interior Ceiling F Non-Detected N/A

Building 229

Building 229 is an operational storage facility. The building exterior is brick masonry.

The roof is wood framed with asphalt shingles. The interior walls are painted brick with a gypsum board ceiling.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles Misc Roof NF Non-Detected N/A

Exterior Window Caulk Misc Exterior NF Non-Detected N/A Concrete Expansion Joint Misc Exterior NF Non-Detected N/A Residual Mastic around Columns Misc Interior NF Non-Detected N/A Gypsum/Joint Compound Misc Interior Walls F Non-Detected N/A Exterior Texture on Concrete Base Surface Exterior F 3% Chrysotile 316SF

Based on the sample analysis, the following materials were found to be Asbestos

Exterior Texture on Concrete Base

Building 300A

A. Building Description and Findings (Inspected 05-13-20)

Building 300A is a mechanical building serving Building 300. The Exterior is brick and cmu walls with a wood framed roof with asphalt shingles.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles/Felt Misc Roof NF Non-Detected N/A

Door Caulk Misc Door NF Non-Detected N/A

Materials

Building 307

C. Building Description and Findings (Inspected 09-15-20)

Building 307 is an abandoned storage/office building that was damaged during the previous hurricane. The building exterior is brick and the roof consist of wood framing and asphalt shingles. The interior walls wood stud and gypsum board/plaster with plaster and acoustical ceilings.

Location Friability Laboratory Result Approx.Quantity

12x12 Cream VCT/Mastic Misc Floors NF Non-Detected N/A

2x2 ACT Misc Ceiling F Non-Detected N/A Gypsum Board/Joint Compound Misc Walls NF Non-Detected N/A Plaster Ceilings/Walls Surf. Walls/Ceiling F Non-Detected N/A Textured Ceiling Surf. Ceiling in Storage F Non-Detected N/A Asphalt Shingles/Felt Misc Main roof NF Non-Detected N/A Exterior Door/Window Caulk Misc Windows NF Non-Detected N/A Built Up Roof Misc Flat Roofs NF Non-Detected N/A Mastic at roof penetrations Misc Roof Penetrations NF Non-Detected N/A

Containing Materials

Building 339

A. Building Description and Findings (Inspected 09-15-20)

Building 339 is a storage building. The building exterior is stucco with metal windows/doors and an asphalt shingle roof. Interior partitions are wood with gypsum board. Flooring consists of VCT and sealed concrete.

Location Friability Laboratory Result Approx.Quantity

Exterior Stucco Surf Exterior Walls NF Non-Detected N/A

Asphalt Shingles/Felt Misc Roof NF Non-Detected N/A Exterior Door/Window Caulk Misc. Exterior

Doors/Windows NF 5% Chrysotile 168LF

9x9 Black VCT (Tile Only) Misc Floor Tile NF 2% Chrysotile 75SF

9x9 Black VCT (Mastic Only) Misc. Floors NF Non-Detected N/A Gypsum Board/Joint Compound Misc Walls NF Non-Detected N/A

Exterior Door/Window Caulk 9x9 Black VCT (Tile Only)

Additional items were found to be asbestos containing materials on previous government provided reports. See attached Appendix A for further information.

ACM Materials found in previous government report in area of work:

- 9x9 Black Floor Tile Mastic. 75SF

- 12x12 Black Floor Tile/Mastic- 575SF

- Adhesive at Board Back- 48SF

- White Heat Shield in attic – 8SF

Building 425

C. Building Description and Findings (Inspected 04/28/20)

Building 425 is an abandoned event building. The building exterior is brick masonry with aluminum windows/doors and an asphalt shingle roof. Interior partitions are wood and metal stud with plaster and gypsum board. Flooring consists of VCT, carpet, tile and sealed concrete.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles Misc. Pitched Roof NF Non-Detected N/A

Exterior Door/Window Caulk Misc Exterior Windows/Doors

NF Non-Detected N/A

Gypsum Board/Joint Compound Misc. Interior Walls NF Non-Detected N/A 2x2 ACT Misc Interior Ceilings NF Non-Detected N/A 12x12 VCT with gray Specks Misc Small Bathrooms NF Non-Detected N/A

Plaster Walls/Ceilings Misc Interior perimeter Walls/Ceilings

NF Non-Detected N/A

Gray Rubber Base/Mastic Misc Interior Walls NF Non-Detected N/A

Built Up Roof Misc Flat Roof NF Non-Detected N/A

Roof Flashing at Reglet Misc Flat Roof NF Non-Detected N/A

Textured Ceiling Surf. Bar Textured Ceiling

F Non-Detected N/A

Roof Flashing at Roof Vents Misc Flat roof NF Non-Detected N/A

16x16 Vinyl Tile/Mastic Misc Flooring in atrium NF Non-Detected N/A

Residual Ceiling Tile Mastic Misc Ceilings throughout.

Residual round spots from previously removed ceilings

NF 3% Chrysotile 12,934SF

Joint Compound Misc Mechanical Room NF Non-Detected N/A

Residual Ceiling Tile Mastic

ACM Materials found in previous government report in area of work:

- Textured Ceiling Material approx. 1,500SF

- 12” Gray Floor Tile & Adhesive- 1,250SF

- Drywall/Joint Compound- 5,250SF

- Exterior Caulking- 25LF

- Transite Panel- 1SF

Building 435

Building 435 is a general storage facility. The building exterior is stucco type system with brick framed windows/doors. The roof consists of wood framing and asphalt shingles. The interior walls are painted cmu block with gypsum board ceilings.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles/Felt Misc Roof NF Non-Detected N/A

Exterior Stucco Surface Exterior F Non-Detected N/A Exterior Door Caulk Misc Exterior NF Non-Detected N/A Exterior Window Caulk Misc Exterior NF 3% Chrysotile 672LF Gypsum/Joint Compound Misc Interior Wall F Non-Detected N/A Chalk Board / Fiberboard Misc Floor NF 5% Chrysotile 100SF Caulk at Chalk/Fiberboard Misc Wall NF 3% Chrysotile 100SF

Exterior Window Caulk Chalk Board / Fiberboard Caulk at Chalk/Fiberboard

Building 436

Building 436 is a general storage facility. The building exterior is stucco with brick framed windows/doors. The roof consists of wood framing and asphalt shingles. The interior walls are painted cmu block with gypsum board ceilings.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles/Felt Misc Roof NF Non-Detected N/A

Exterior Stucco Surface Exterior F Non-Detected N/A Exterior Door Caulk Misc Exterior NF 3% Chrysotile 50LF Exterior Window Caulk Misc Exterior NF 3% Chrysotile 320LF Gypsum/Joint Compound Misc Interior Wall F Non-Detected Gray 12x12 VCT Mastic Misc Wall F Non-Detected Rubber Base/Mastic Misc Wall NF Non-Detected

Exterior Door Caulk Exterior Window Caulk

Building 438

A. Building Description and Findings (Inspected 05-20-20)

Building 438 is an abandoned storage/office building that was damaged during the previous hurricane. The building exterior is brick and the roof consist of wood framing and asphalt shingles.

Location Friability Laboratory Result Approx.Quantity

Asphalt shingles/felt Misc Floors NF Non-Detected N/A

Gypsum Board/Joint Compound Misc Ceiling NF Non-Detected N/A Gray Rubber Base/Mastic Misc Walls NF Non-Detected N/A

Building 524

A. Building Description and Findings (Inspected 05-21-20)

Building 524 is an abandoned office/event building. The building exterior is brick masonry with aluminum windows/doors and an asphalt shingle roof. Interior partitions are wood and metal stud with plaster and gypsum board. Flooring consists of VCT, carpet, tile and sealed concrete.

Location Friability Laboratory Result Approx.Quantity

Asphalt Shingles Misc. Pitched Roof NF Non-Detected N/A

Gypsum Board/Joint Compound Misc Exterior Windows/Doors

NF Non-Detected N/A

Wall Vapor Barrier Misc. Exterior Walls NF Non-Detected N/A 2x2 ACT Misc Interior Ceilings F Non-Detected N/A Plaster Ceiling Misc Interior Ceiling F Non-Detected N/A Door/Window Caulk Misc Door/Window

Caulk NF Non-Detected N/A

Caulk at Brick Step Flashing Misc Exterior Reglet NF Non-Detected N/A

Flashing at Roof Vent Misc Exterior Roof NF Non-Detected N/A

Built Up Roof Misc Flat Roof NF Non-Detected N/A

Expansion Joint Misc Expansion Joint at Exterior Walls

NF 2% Chrysotile 180LF

Residual Mastic at Exterior Wall

Misc Residual Caulk at 2nd floor exterior walls near flat

NF 8% Chrysotile 10LF roof 12x12 Cream VCT/Mastic Misc Flooring NF Non-Detected N/A

Rubber Base/ Mastic Misc Wall Base NF Non-Detected N/A

Expansion Joint Residual Mastic at Exterior Wall

ACM Materials found in previous government report in area of work:

- Fibrous Debris approx. 250SF

- Cloth Lagging Material- 20SF

- Gray Roof Sealant- 100SF

- Ceiling Tile Adhesive- 2800SF

- Black Roof Sealant- 1200SF

Building 731

A. Building Description and Findings (Inspected 05-14-20)

Building 731 is an abandoned restroom building that was damaged during the previous hurricane. The building exterior is cmu and the roof consist of wood framing and asphalt shingles.

Location Friability Laboratory Result Approx.Quantity

Asphalt shingles/felt Misc Roof NF Non-Detected N/A

Gypsum Board/Joint Compound Misc Ceiling NF Non-Detected N/A Door/Window Caulk Misc Windows NF Non-Detected N/A

Building 738

Building 738 is a grounds equipment shed. The building is a pre-engineered metal structure with exterior metal panels at the walls and roof. The interior walls are gypsum board and ceilings are drop down acoustical ceiling tiles.

Location Friability Laboratory Result Approx.Quantity

Black 12x12 VCT Misc Floor NF Non-Detected N/A

Gasket material on heat exchanger Misc NF Non-Detected N/A Transite panel material bathroom walls

Misc Walls F 20% Chrysotile 400SF

2x2 ACT Misc Ceiling F Non-Detected N/A Exterior Window Caulk Misc Exterior NF Non-Detected N/A Window Glaze Misc Exterior F Non-Detected N/A Gypsum/Joint Compound Misc Interior Wall F Non-Detected N/A Green VCT 12x12 under black on 1st Floor

Misc Floor NF Non-Detected N/A

Cream 12x12 VCT Misc Floor NF Non-Detected N/A

Transite panel material bathroom walls

Building 762

Building 762 is an abandoned office building. The building exterior is brick masonry with aluminum windows/doors and an asphalt shingle roof. Interior partitions are wood and metal stud with plaster and gypsum board. Flooring consists of VCT, carpet, tile and sealed concrete.

Asphalt Shingles Misc. Pitched Roof NF Non-Detected N/A

Plaster Walls/Ceiling Misc Interior Walls/Ceiling

NF Non-Detected N/A

12x12 Cream VCT/Mastic Misc. Floors under Carpet

NF Non-Detected N/A

2x2 ACT Misc Interior Ceilings F Non-Detected N/A Exterior Door/Window Caulk Misc Exterior

Doors/Windows NF Non-Detected N/A

Sealant at Brick Chimney Misc Roof Sealant at Chimney

NF 8% Chrysotile 6LF

Sealant at Brick Chimney

ACM Materials found in previous government report in area of work:

- Pipe Insulation approx. 32LF

- Cloth Expansion Joint material- 4SF

- Residual mastic- 15SF

Building 812

C. Building Description and Findings (Inspected 01-24-18 and 04-19-18)

Building 812 is a visitor/guard building. The building exterior is brick and the roof consists of wood framing and asphalt shingles. The interior walls wood stud and gypsum board with gypsum board ceilings.

Location Friability Laboratory Result Approx.Quantity

Asphalt shingles Misc Roof NF Non-Detected N/A

Storefront caulk Misc Doors NF Non-Detected N/A Window caulk Misc Windows NF Non-Detected N/A Asphalt shingles Misc Roof NF Non-Detected N/A Window Caulk Misc Windows NF Non-Detected N/A Gypsum Board/Joint Compound Misc Walls/Ceiling F Non-Detected N/A

Building 812A

A. Building Description and Findings (Inspected 01-24-18)

Building 812A is contractor vetting office. The building consists of a pre-fabricated metal building structure with exterior metal panels at the walls and pvc membrane roof.

Interior walls are gypsum board and the ceilings are drop down acoustical tile and gypsum board.

Location Friability Laboratory Result Approx.Quantity

Roof Membrane Misc. Roof NF Non-Detected N/A

Door Caulk Misc. Door NF Non-Detected N/A Gypsum Walls Misc. Walls F Non-Detected N/A Gypsum Ceiling Misc. Ceiling F Non-Detected N/A VCT/mastic Misc. Floor NF Non-Detected N/A

Based on the sample analysis none of the materials were found to be Asbestos

Building 911

Building 911 is a storage building. The building exterior is CMU block walls with a wood framed and asphalt shingle roof.

Asphalt shingles Misc Roof NF Non-Detected N/A

Building 1010

Building 1010 is a storage facility. The building is a pre-engineered metal structure with exterior metal panels at walls and roof. There is an additional room extension made of wood framing and wood sheathing. The interior walls are wood paneling with a gypsum board and drop in acoustical tile ceiling.

Location Friability Laboratory Result Approx.Quantity

Exterior roof sealant/silver Misc Exterior NF 3% Chrysotile 1250SF Dark Brown 9x9 VCT Misc Floors NF 5% Chrysotile 1000SF

12x12 Cream VCT Misc Floor NF <1% Chrysotile 48SF 12x12 Dark Blue VCT Misc Floor NF Non-Detected N/A 12x12 Black VCT Misc Floor NF Non-Detected N/A 12x12 Gray VCT Misc Floor NF 2% Chrysotile 50SF 12x12 Light Blue VCT Misc Floor NF Non-Detected N/A 12x12 Dark Beige VCT Misc Floor NF 5% Chrysotile 50SF 12x12 ACT I Misc Floor NF Non-Detected N/A 12x12 ACT II Misc Floor NF Non-Detected N/A Fiberboard Misc Walls F Non-Detected N/A Gypsum/Joint Ceiling Misc Exterior NF Non-Detected N/A Flat Roof Coating TSI Exterior NF Non-Detected N/A

Exterior roof sealant/silver Dark Brown 9x9 VCT

12x12 Cream VCT 12x12 Gray VCT 12x12 Dark Beige VCT

Building 1203

C. Building Description and Findings (Inspected 04/20/20)

Building 1203 is an abandoned workshop. The building exterior is cmu masonry with an asphalt shingle roof. Interior partitions are cmu masonry as well as wood framed with gypsum board. Flooring is VCT and sealed concrete.

Location Friability Laboratory Result Approx.Quantity

12x12 Black VCT & Mastic Misc. Interior Floor NF 5% Chrysotile 320SF

Window Glazing Misc Exterior Windows

NF Non-Detected N/A

Gypsum Board/Joint Compound Misc Interior Walls NF Non-Detected N/A

Exterior Door/Window Caulk Misc Exterior Doors NF 1% Chrysotile 350SF

12x12 Black VCT & Mastic Exterior Door/Window Caulk

ACM Materials found in previous government report in area of work:

- Window Glazing Material– approx. 576 LF

- White Heat Shield – approx. 2 SF

- 9” Black Floor Tile & Mastic- 224SF

- Gray Roofing Sealant- 2SF

Building 1307

Building 1307 is a wood framed storage building with vinyl siding and an asphalt shingle roof.

Asphalt shingles/felt Misc Roof NF Non-Detected N/A

Building 1315

A. Building Description and Findings (Inspected 05/14//20)

Building 1315 is a wood framed storage building with vinyl siding and an asphalt shingle roof.

Location Friability Laboratory Result Approx.Quantity

Plaster Walls Surf. Interior Wall NF <1% Chrysotile 400SF

Asphalt Shingles Misc Roof NF Non-Detected N/A Transite Panel Debris Misc Interior NF 15% Chrysotile 5SF Built Up Roof Misc Roof NF 3% Chrysotile 192SF Roof Debris Misc Exterior Debris NF 5% Chrysotile 5SF Window Glaze Misc Exterior Mech

Room window NF Non-Detected N/A

Exterior Door Caulk Misc Exterior mech.

Door

NF Non-Detected N/A

Plaster Walls Transite Panel Debris Built Up Roof Roof Debris

Additional items were found to be asbestos containing materials on previous government provided reports. See attached Appendix A for further information.

ACM Materials found in previous government report in area of work:

- Pipe Insulation– approx. 9 LF

- Transite Panel material – approx.1024 SF

- exterior Caulking- 17 LF

- Gray Roof Sealant- 160 SF

- HVAC Duct Insulation- 544 SF

Building 1409

Building 1409 is an operational training building. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board and the roof is wood framed with asphalt shingles.

Location Friability Laboratory Result Approx.Quantity

Gypsum Board/ Joint Compound Misc Interior NF Non-Detected N/A

Exterior Window Caulk Misc Exterior NF Non-Detected N/A

Textured Masonry Wall Surf. Exterior NF Non-Detected N/A

Shingles/ Felt Misc Roof NF Non-Detected N/A

Window Glazing Misc Exterior NF Non-Detected N/A

Concrete Expansion Joint Misc Interior Floor NF Non-Detected N/A

Caulk at Roof Vents Misc Roof NF Non-Detected N/A purpose of any demolition/renovation activities and disturbance.

ACM Materials found in previous government report in area of work:

-Concrete expansion joint (perimeter and center joints) – approx. 484LF -Exterior window glazing – approx. 1584LF -Gray roofing sealant at box ridge vents – 160LF

Building 1410

Building 1410 is an operational office building. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board and the roof is wood framed with asphalt shingles.

Location Friability Laboratory Result Approx.Quantity

Textured Wall Surf. Exterior NF Non-Detected N/A

Cream VCT (Floor tile) Misc Interior NF Non-Detected N/A

Cream VCT (Mastic) Surf. Interior NF Non-Detected N/A

Exterior Door/ Window Caulk Misc Exterior NF Non-Detected N/A

Rubber Base/ Mastic Misc Interior NF Non-Detected N/A

Gypsum Board/ Joint Compound Misc Interior NF Non-Detected N/A

2X2 ACT Misc Ceilings NF Non-Detected N/A

Caulk at Roof Vent Misc Roof NF Non-Detected N/A

Building 1728

A. Building Description and Findings (Inspected 03-16-18)

Building 1728 is a recreation pavilion snack stand. The building exterior cmu block walls with a built up roof.

Built up roof Misc Roof NF Non-Detected N/A

Building 1742

Building 1742 is an indoor handball court. The building exterior is brick with a wood framed, asphalt shingle roof. The interior walls and ceiling are high impact gypsum board.

Location Friability Laboratory Result Approx.Quantity

Fiberboard interior walls Misc Interior Walls F Non-Detected N/A

Flooring material, yellow Misc Interior Floor NF Non-Detected N/A Exterior mastic on duct insulation Misc Exterior NF Non-Detected N/A

Building 1804

Building 1804 is vehicle storage building. The building is a pre-engineered structure with metal wall and roof panels. There are no interior partitions.

Exterior Caulk Misc Exterior NF Non-Detected N/A

Building 1808

Building 1808 is vehicle storage building. The building is a pre-engineered structure with metal wall and roof panels. There are no interior partitions.

Exterior Caulk Misc Exterior NF Non-Detected N/A

Building 2043

Building 2043 is a golf course snack stand. The building exterior is wood siding with a wood framed, asphalt shingle roof. The interior walls and ceiling are FRP.

Location Friability Laboratory Result Approx.Quantity

Vinyl Floor/mastic Misc Interior Floor NF Non-Detected N/A

Building H48

Building H48 is a general storage shed. The building exterior is brick masonry. The roof is wood framed with asphalt shingles. The interior walls are brick with a transite panel ceiling.

Location Friability Laboratory Result Approx.Quantity

Ceiling transite board Misc Ceiling NF 15% Chrysotile 150SF

Ceiling transite board

Building PT6

Building PT6 is an abandoned office building. The building exterior is brick with stucco finish and a wood framed, asphalt shingle roof. The interior walls are gypsum board and painted brick with a gypsum board ceiling

Location Friability Laboratory Result Approx.Quantity

Exterior Stucco Surface Exterior Walls F <1% Chrysotile 2,250SF

Exterior Window Glaze Misc Exterior F Non-Detected Gypsum Board, Joint Compound Misc Interior F Non-Detected 12x12 Gray VCT 1st Floor Misc Interior Floor NF <1% Chrysotile 200SF Black VCT 2nd Floor Misc Interior Floor NF Non-Detected Tan VCT under black 2nd floor Misc Interior Floor NF 3% Chrysotile 300SF Fiberboard Misc Interior F Non-Detected Exterior Window/Door caulk Misc Exterior NF Non-Detected Asphalt Shingles Misc Roof NF Non-Detected Concrete expansion joint, perimeter floor floor

Misc Exterior NF 5% Chrysotile 160LF

Dark gray VCT, 1st floor bathroom

Misc Interior Floor NF <1% Chrysotile 200SF

Concrete expansion joint 1st floor middle of floor, square

Misc Interior NF 8% Chrysotile 15LF

Based on the sample analysis, the following materials were found to be Asbestos Containing

Exterior Stucco 12x12 Gray VCT 1st Floor Tan VCT under black 2nd floor Dark gray VCT, 1st floor bathroom Concrete expansion joint, perimeter floor floor Concrete expansion joint 1st floor middle of floor, square

Building SH13

Building SH13 is an abandoned metal guard house with acoustical ceiling.

2x2 Acoustical Ceiling Misc Ceiling F Non-Detected N/A

Building SH22

Building SH22 is an abandoned masonry guard house with gypsum board ceiling and asphalt shingle roof.

Location Friability Laboratory Result Approx.Quantity

Exterior Door Caulk Misc Exterior Door N Non-Detected N/A

Gypsum Board/Joint Compound Misc Interior Ceiling F Non-Detected N/A

Building SH39

A. Building Description and Findings (Inspected 04-28-20)

Building SH39 is a head facility and maintenance building. The building is constructed with cmu and wood framing and metal wall/roof panels. Interior walls consist of cmu and wood framing with gypsum board, and the floors are sealed concrete.

Location Friability Laboratory Result Approx.Quantity

Gypsum Board/Joint Compound Misc. Interior Walls NF Non-Detected N/A

Rubber Base/Mastic Misc. Interior Walls NF Non-Detected N/A

Exterior Door Caulk Misc. Exterior Doors NF Non-Detected N/A

Building SHE22

Building SHE22 is a metal restroom building with gypsum board ceiling and metal roof.

Location Friability Laboratory Result Approx.Quantity

Gypsum Board/Joint Compound Misc Interior Walls/Ceilings

NF Non-Detected N/A

See attached for Accreditations, Asbestos Lab Results and Chain of Custody. If further information is required, please contact me at 1-252-636-8778

Report Prepared by:

Christopher B. Walker North Carolina Asbestos Inspector Accreditation# 12878 The Walker Group Architecture, Inc., PO Box 541, New Bern, NC 28560

DRAWING NO.DATE

DRAWN BY

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

BUILDING 3

MCB CAMP LEJEUNE

1"=30'-0"

5-27-19

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\3\3-1.dwg

GROUP

ARCHITECTURE

WALKER

th e

N

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

EXTERIOR CONCRETE EXPANSION JOINT AT BUILDING PERIMETER - 1250SF

AutoCAD SHX Text

AutoCAD SHX Text

EXTERIOR RESIDUAL CAULK AT REMOVED AWNING - 350SF

AutoCAD SHX Text

FIRST FLOOR

AutoCAD SHX Text

2ND FLOOR

AutoCAD SHX Text

REMOVED AWNING LOCATION

AutoCAD SHX Text

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\39\39-1.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 39

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text ASBESTOS IDENTIFIED IN ROOF MASTIC AT EXHUAST FLUE IN THIS LOCATION, APPROX. 2SF.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN ROOF MASTIC AT MECHANICAL EXHUAST , APPROX. 16LF.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN 12X12 BLACK VCT/MASTIC UNDER STAIRS, APPROX. 16SF.

AutoCAD SHX Text ASBESTOS IDENTIFIED IN RESIDUAL MASTIC FROM PREVIOUSLY REMOVED VCT, APPROX. 660SF.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN 12X12 CREAM VCT/MASTIC APPROX. 487SF.

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\113\113.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 113

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text ASBESTOS IDENTIFIED IN THERMAL SYSTEMS INSULATION AS INDICATED BY LINE TYPE IN ATTIC SPACE. ALL MUDDED FITTINGS AT INSULATION WERE FOUND TO CONTAIN ASBESTOS.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR WINDOW CAULK. APPROX. 238LF

ASBESTOS IDENTIFIED IN EXTERIOR WINDOW CAULK TYP. AT EXT. WINDOWS

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\117\117.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 117

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text ASBESTOS IDENTIFIED IN EXTERIOR CAULK AT REGLET FLASHING AT CANOPY AND BRICK FLASHING. TYPICAL AT CANOPIES.

AutoCAD SHX Text ASBESTOS IDENTIFIED IN EXTERIOR CAULK AT REGLET FLASHING ON CANOPYS. APPROX. 30LF.

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\229\229.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 229

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text ASBESTOS IDENTIFIED IN EXTERIOR CONCRETE BASE SURFACE TEXTURE. TYPICAL AT BUILDING PERIMETER.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR CONCRETE BASE SURFACE TEXTURE, APPROX. 316SF.

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

BUILDING 339

MCB CAMP LEJEUNE

1/16"=1'-0"

09-17-20

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\339\339.dwg

GROUP

ARCHITECTURE

WALKER

th e

N

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

9X9 BLACK VCT (VCT ONLY) - APPROX. 75SF

ASBESTOS LOCATED AT EXTERIOR DOOR/WINDOW CAULK, TYP.

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

BUILDING 425

MCB CAMP LEJEUNE

1/16"=1'-0"

05-18-20

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\425\425-1.dwg

GROUP

ARCHITECTURE

WALKER

th e

N

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

RESIDUAL CEILING TILE MASTIC - APPROX. 12,934SF

AutoCAD SHX Text *SEE GOV'T ASBESTOS REPORT AND PLAN FOR ADDITIONAL ASBESTOS CONTAINING MATERIAL LOCATIONS

AutoCAD SHX Text

1ST FLOOR

2ND FLOOR

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\435\435.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 435

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR WINDOW CAULK, APPROX. 672LF

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN CHALK BOARD/FIBERBOARD, APPROX. 100SF.

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN CAULK AT CHALK BOARD/FIBERBOARD, APPROX. 100SF.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR WINDOW CAULK, TYPICAL AT EXTERIOR WINDOWS.

ASBESTOS IDENTIFIED IN CHALK BOARD AND CHALK BOARD CAULKING/SEALANT

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\436\436.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 436

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR DOOR CAULK, APPROX. 50LF.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR WINDOW CAULK, APPROX. 320LF.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR WINDOW CAULK. TYPICAL FOR (20) WINDOWS.

ASBESTOS IDENTIFIED IN EXTERIOR DOOR CAULK. TYPICAL FOR (3) DOORS.

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

BUILDING 524

MCB CAMP LEJEUNE

1/16"=1'-0"

05-28-20

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\524\524-1.dwg

GROUP

ARCHITECTURE

WALKER

th e

N

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

EXTERIOR EXPANSION JOINT MATERIAL - APPROX. 180LF

AutoCAD SHX Text

EXTERIOR EXPANSION JOINT MATERIAL - APPROX. 180LF

AutoCAD SHX Text

EXTERIOR EXPANSION JOINT MATERIAL - APPROX. 180LF

AutoCAD SHX Text

EXTERIOR EXPANSION JOINT MATERIAL - APPROX. 180LF

AutoCAD SHX Text

RESIDUAL MASTIC AT WALL ABOVE FLAT ROOF - APPROX. 10LF

AutoCAD SHX Text

SEE 2017 CAMP LEJEUNE SURVEY FOR ADDITIONAL ASBESTOS CONTAINING MATERIALS

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\738\738-1.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 738

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN TRANSITE PANEL IN 2ND FLOOR BATHROOMS, APPROX. 400SF

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR WINDOW CAULK. TYPICAL FOR (20) WINDOWS.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN TRANSITE PANELING LOCATED ON THE WALLS OF THE BATHROOM.

2ND FLOOR

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

BUILDING 762

MCB CAMP LEJEUNE

1/8"=1'-0"

5-27-20

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\762\762.dwg

GROUP

ARCHITECTURE

WALKER

th e

N

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

ROOF SEALANT AT BRICK CHIMNEY - APPROX. 6LF

*SEE GOV'T ASBESTOS REPORT AND PLAN FOR ADDITIONAL ASBESTOS CONTAINING MATERIAL LOCATIONS

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\1010\1010.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING 1010

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text ASBESTOS IDENTIFIED IN EXTERIOR METAL ROOF/WALL PANEL SEALANT. TYPICAL OVER ENTIRE BUILDING.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR ROOF SEALANT, APPROX. 1250SF.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN DARK BROWN 9X9 VCT/MASTIC, APPROX. 1000SF.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN CREAM 12X12 VCT/MASTIC, APPROX. 48SF.

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN GRAY 12X12 VCT/MASTIC, APPROX. 50SF.

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN DARK BEIGE 12X12 VCT/MASTIC, APPROX. 50SF.

AutoCAD SHX Text

AutoCAD SHX Text ASBESTOS IDENTIFIED IN DARK BROWN FLOOR TILE AND MASTIC THROUGHOUT BUILDING. IDENTIFIED BY HATCH.

ASBESTOS IDENTIFIED IN CREAM, GRAY, AND DARK BEIGE VCT AND MASTIC, 2ND LAYER OVER DARK BROWN VCT

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

BUILDING 1203

MCB CAMP LEJEUNE

1/16"=1'-0"

05-07-20

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\1203\1203.dwg

GROUP

ARCHITECTURE

WALKER

th e

N

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text 12x12 BLACK VCT AND MASTIC - APPROX. 320SF

AutoCAD SHX Text

ASBESTOS LOCATED IN WHITE DOOR/WINDOW CAULKING. TYP.

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

BUILDING 1315

MCB CAMP LEJEUNE

1/16"=1'-0"

05-27-20

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\1315\1315-1.dwg

GROUP

ARCHITECTURE

WALKER

th e

N

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

INTERIOR PLASTER WALL - APPROX. 400SF

AutoCAD SHX Text

BUILT UP ROOF OVER MECHANICAL ROOM - APPROX. 192SF

AutoCAD SHX Text

ROOF DEBRIS - APPROX. 5SF

AutoCAD SHX Text

TRANSITE PANEL DEBRIS - APPROX. 5SF

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\H48\H48.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING H48

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text ASBESTOS IDENTIFIED IN TRANSITE PANEL CEILING, APPROX. 150SF. TYPICAL THROUGHOUT BUILDING.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN CEILING TRANSITE BOARD, APPROX. 150SF

SCALE

PROJECT NO

ASBESTOS LOCATION PLAN

MCB CAMP LEJEUNE

1/16"=1'-0"

CBW

20-0001

G:\Projects\2020\2001.IR20\Drawings\100%\Package B\PT6\PT6-1.dwg

GROUP

ARCHITECTURE

WALKER

th e

BUILDING PT6

3-24-18

AutoCAD SHX Text Copyright 2006 by THE WALKER GROUP

AutoCAD SHX Text ARCITECTURE,INC. All rights reserved.

AutoCAD SHX Text 252-636-8992(fax)

AutoCAD SHX Text

PO BOX 541, NEW BERN, NC 28563

AutoCAD SHX Text c

AutoCAD SHX Text 252-636-8778

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN TAN VCT UNDER BLACK

AutoCAD SHX Text

1ST FLOOR

AutoCAD SHX Text

2ND FLOOR

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN CLOTH EXPANSION JOINT MATERIAL AT CONC. PERIMETER.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN CLOTH EXPANSION JOINT MATERIAL AT SQUARE FLOOR CUTOUT.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR STUCCO, TYPICAL FOR ENTIRE BUILDING.

AutoCAD SHX Text

ASBESTOS IDENTIFIED GRAY AND DARK GRAY VCT ON 1ST FLOOR.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN TAN VCT UNDER BLACK 2ND FLOOR, APPROX. 300SF.

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN CONCRETE EXPANSION JOINT PERIMETER FLOOR, APPROX. 160LF.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text ASBESTOS IDENTIFIED IN CONCRETE EXPANSION JOINT 1ST FLOOR MIDDLE OF FLOOR, SQUARE, APPROX. 15LF.

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN EXTERIOR STUCCO, APPROX. 2,250SF.

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN 12X12 GRAY VCT/MASTIC AT 1ST FLOOR, APPROX. 200SF.

AutoCAD SHX Text

AutoCAD SHX Text

ASBESTOS IDENTIFIED IN 12X12 DARK GRAY VCT/MASTIC AT 1ST FLOOR, APPROX. 200SF.

EMSL Analytical, Inc.

706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / greensborolab@emsl.com

021902963EMSL Order:

Customer ID: WALK85

Customer PO:

Project ID:

Attention: Phone:Chris Walker (252) 636-8778

Fax:The Walker Group Architecture (252) 636-8992

Received Date:PO Box 541 04/30/2019 11:30 AM

Analysis Date:New Bern, NC 28563 05/01/2019

Collected Date: 04/24/2019

Project: Bldg 3

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

021902963-0001

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Gray

Non-Fibrous

Homogeneous

Window Caulk

021902963-0002

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Gray

Non-Fibrous

Homogeneous

Window Caulk

03-Floor Tile

021902963-0003

None DetectedQuartz

Non-fibrous (Other)

25%

75%

White

Non-Fibrous

Homogeneous

Beige VCT/Mastic

03-Mastic

021902963-0003A

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Beige VCT/Mastic

03-Leveler

021902963-0003B

None DetectedCa Carbonate

Non-fibrous (Other)

10%

90%

Cellulose<1%Tan

Non-Fibrous

Homogeneous

Beige VCT/Mastic

04-Floor Tile

021902963-0004

None DetectedQuartz

Non-fibrous (Other)

25%

75%

Gray/Beige

Non-Fibrous

Homogeneous

Beige VCT/Mastic

04-Mastic

021902963-0004A

None DetectedNon-fibrous (Other)100%Cellulose<1%Tan

Non-Fibrous

Homogeneous

Beige VCT/Mastic

04-Leveler

021902963-0004B

None DetectedQuartz

Ca Carbonate

Non-fibrous (Other)

1%

10%

89%

Cellulose<1%Gray

Non-Fibrous

Homogeneous

Beige VCT/Mastic

021902963-0005

Not SubmittedRubber Base/Mastic

Sample bag empty

021902963-0006

None DetectedNon-fibrous (Other)100%Gray/Beige

Non-Fibrous

Homogeneous

Rubber Base/Mastic

Composite result

021902963-0007

None DetectedPerlite

Non-fibrous (Other)

10%

10%

Cellulose

Min. Wool

40%

40%

Tan/White

Fibrous

Homogeneous

2x2 ACT

021902963-0008

None DetectedPerlite

Non-fibrous (Other)

10%

10%

Cellulose

Min. Wool

35%

45%

Gray/White

Fibrous

Homogeneous

2x2 ACT

021902963-0009

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Beige

Non-Fibrous

Homogeneous

Exterior Door Caulk

021902963-0010

None DetectedCa Carbonate

Non-fibrous (Other)

10%

89%

Cellulose

Fibrous (Other)

<1%

1%

Beige

Non-Fibrous

Homogeneous

Exterior Door Caulk

021902963-0011

None DetectedCa Carbonate

Non-fibrous (Other)

5%

14%

Cellulose

Glass

80%

1%

Brown/Gray/White

Fibrous

Homogeneous

Gypsum Board/Joint

Compound

Composite result

Initial report from: 05/02/2019 08:51:49

Page 1 of 3ASB_PLM_0008_0001 - 1.78 Printed: 5/2/2019 8:51 AM

Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / greensborolab@emsl.com

021902963EMSL Order:

Customer ID: WALK85

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

021902963-0012

None DetectedNon-fibrous (Other)84%Cellulose

Glass

15%

1%

Brown/Gray

Fibrous

Homogeneous

Gypsum Board/Joint

Compound

No joint compound present

021902963-0013

None DetectedNon-fibrous (Other)92%Glass8%Brown/Gray/Tan

Fibrous

Homogeneous

Asphalt Shingles/ Felt

021902963-0014

None DetectedNon-fibrous (Other)92%Glass8%Gray/Tan/Black

Fibrous

Heterogeneous

Asphalt Shingles/ Felt

021902963-0015

None DetectedNon-fibrous (Other)97%Synthetic3%Gray/Tan

Fibrous

Homogeneous

Carpet Mastic

021902963-0016

None DetectedNon-fibrous (Other)99%Cellulose

Synthetic

<1%

1%

Gray/Tan

Non-Fibrous

Homogeneous

Carpet Mastic

021902963-0017

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Gray

Non-Fibrous

Homogeneous

Residual Mastic at

2nd Floor Windows

021902963-0018

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Cellulose<1%Gray/White

Non-Fibrous

Homogeneous

Residual Mastic at

2nd Floor Windows

021902963-0019

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Hair<1%Tan/Beige

Non-Fibrous

Homogeneous

Plaster Ceiling

021902963-0020

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Hair<1%Tan

Non-Fibrous

Homogeneous

Plaster Ceiling

021902963-0021

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Hair<1%Tan

Non-Fibrous

Homogeneous

Plaster Ceiling

021902963-0022

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Hair<1%Tan/White

Non-Fibrous

Homogeneous

Plaster Ceiling

021902963-0023

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Hair<1%Tan

Non-Fibrous

Homogeneous

Plaster Ceiling

021902963-0024

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Hair<1%Tan

Non-Fibrous

Homogeneous

Plaster Ceiling

021902963-0025

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Hair<1%Tan

Non-Fibrous

Homogeneous

Plaster Ceiling

021902963-0026

None DetectedQuartz

Non-fibrous (Other)

30%

70…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .