Building 40 Asbestos Survey.pdf
PDF 1 MB Posted
- Attached to
- Infrastructure Reset Demo Buildings - Package B Federal contract opportunity
- Solicitation number
- N4008521B2504
About this file
This document contains an asbestos survey report for Building 40 at Marine Corps Base Camp Lejeune. The report details the inspection of Building 40 conducted on January 24, 2018 by an accredited inspector. Samples were collected from various building materials and analyzed by a NVLAP-accredited laboratory. Laboratory results found that samples of exterior door caulk, exterior window caulk, cream vinyl composition tile and mastic, acoustic ceiling tile, spray applied texture on concrete walls, and green vinyl composition tile and mastic all returned negative for asbestos. The related federal contract opportunity is for the demolition of various buildings at Marine Corps Base Camp Lejeune as part of an infrastructure reset, according to the solicitation plans and specifications. The soliciting agency is the Department of the Navy Naval Facilities Engineering Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N4008521B2504 Amendment08.pdf | ||
| N4008521B2505 Amendment08.pdf | ||
| N4008521B2504 Amendment07.pdf | ||
| EMD Decision Memorandum.pdf | ||
| N4008521B2504 Amendment06.pdf | ||
| Building 40 Lead Survey.pdf | ||
| Building 40 Demo Plans.pdf | ||
| Amended Section 02 82 16 Removal of Asbestos Materials.pdf | ||
| N4008521B2504 Amendment05.pdf | ||
| N4008521B2504 Amendment04.pdf | ||
| N4008521B2504 Amendment03.pdf | ||
| Contractor_Environmental_Guide.pdf | ||
| N4008521B2504 Amendment02.pdf | ||
| N4008521B2504 Amendment01.pdf | ||
| N4008521B2504Dwgs.pdf | ||
| N4008521B2504AsbestosSurveyReport.pdf | ||
| N4008521B2504LeadSurveyReport.pdf | ||
| N4008521B2504Solicitation.pdf | ||
| N4008521B2504Specs.pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey Demolish Various Building FY18 at MCB Camp Lejeune (Phase 2)
Demolish Various Buildings at MCB Camp Lejeune (Phase 2) Marine Corps Base Camp Lejeune
Project # 17-0072
Report Prepared By:
Christopher B. Walker
The Walker Group Architecture, Inc May 31, 2018
WGA Project No. – 1740.IR18
Project Information
The Walker Group Architecture, Inc. was contracted by Camp Lejeune to conduct an asbestos sampling survey for Buildings/Structures 11, 26, 39, 40, 113, 116, 117, 117A, 216, 229, 424, 432, 435, 436, 512, 521, 531, 738, 797, 798, 799, 812, 812A, 824, 911, 1010, 1728, 1742, 1909, 1933, 2043, 2626, 2627, 2627, BB54, BB246, FC250A, FC250B, FC250C, FC260, FC318, FC416, FC416A, G699, H48, LCH4011, LCH4012, LCH4012A, LCH4012B, LCH4038, M151A, M151B, M151C, M151D, M225, M226, M227, M228, M229, M232, M236, M305, M441, PT6, S1918, S1934, S1971, S1972, S1973, S1976, S1980, S1981, S1986, SA42, STC911, TC760, TC761, TC762, TC804, TC806, TC807, TC817, TC829, TC836, TC838, TC839, TC942, TC1004, TC1006, TC1019, TC1026, TC1027, TC1060, TC1061, TC1062, TC1063, TC1143, and VL331. Buildings or structures S1971, SG648, FC127, FC130, LCH4030, S1983, RR95, SBB108, SG648, SVL335 SRR57, SRR58, and SVL328 were also contracted for a survey however, the buildings or structures did not contain any suspect materials to sample after site investigation. The specified buildings or structures are slated for demolition on board Marine Corps Base Camp Lejeune. An asbestos survey has been requested prior to disturbance of any potential asbestos containing materials (ACM).
Scope of Services
A. The survey was performed on January 24th, February 2nd, February 8th, February 17th, March 1st, March 11th, March 16-17th, March 23rd, March 28th, and April 19, 2018, by Christopher B. Walker (NC Accredited Inspector #12878, expires January 31, 2019).
The sampling was conducted in general accordance with the U.S. Environmental Protection Agency (EPA) requirements as defined in the asbestos Hazards Emergency Response Act (40 CFR Part 763) guidelines (AHERA) and in general accordance with the North Carolina Health Hazards Control Unit (NCHHCU).
B. The survey was conducted to identify the presence of asbestos containing materials (ACM) prior to repairs to the building.
C. The building was assessed to determine homogenous areas (groups of materials appearing to have been installed in the same general time period and uniform in color and texture).
D. As per AHERA, sufficient samples were collected from random locations of each homogenous area, with the number of samples based on the following criteria:
a. Thermal Insulation Materials (piping, breeching, boiler insulation, etc.) – A minimum of (3) samples are required. Patch areas (less than 6 square or liner feet) may have (2) sample collected.
b. Surfacing Materials (plaster, fireproofing, etc.) – A minimum of (7) samples are to be taken for areas greater than 5,000 square feet, five (5) samples for areas greater than 1,000 square feet, but less than 5,000 square feet, three
(3) samples for areas less than 1,000 square feet, two (2) samples for patching materials.
c. Miscellaneous Materials (flooring, adhesives, roofing, wallboard, etc.) – A minimum of (2) samples are required.
If any one sample of a material from a homogenous area is found to be positive, then that material is considered positive, regardless of results of other samples of that material, within that area.
Samples
A. The Walker Group Architecture collected suspect samples and shipped them to EMSL Analytical, Inc. (NVLAP Accredited Laboratory 102104-0) for PLM (polarized Light Microscopy) analysis. In an effort to reduce cost, the Walker Group instructed the laboratory to Stop Analysis at the first positive sample for each suspect material HGA and not to analyze the remaining samples from the same HGA.
Building 40
Findings
A. Building Description and Findings (Inspected 01-24-18)
Building 40 is a family services center. The building exterior is brick and the roof consists asphalt shingles. Interior walls are gypsum board, cmu, and the ceilings are drop down acoustical ceiling tile. Ductwork was insulated with non-suspect fiberglass insulation.
B. Laboratory Results
Material Material Type
Location Friability Laboratory Result Approx.Quantity
Exterior Door Caulk Misc Exterior Doors NF Non-Detected N/A
Exterior Window Caulk Misc Exterior Windows NF Non-Detected N/A
Cream w/blue speck VCT/mastic Misc Floors NF Non-Detected N/A
2x2 ACT Misc Ceiling F Non-Detected N/A
Spray Applied Texture on concrete Corridor Walls
Surface Walls F Non-Detected N/A
Green VCT/mastic Misc Floors NF <1% Chrysotile 1,396SF
Black VCT/mastic Misc Floors NF 5% Chrysotile 13SF
Gypsum/Joint compound Misc Walls F Non-Detected N/A
Mastic under carpet with self leveling compound
Misc Floors NF 5% Chrysotile 16,470SF
Transite wall panel in attic Misc Attic NF 15% Chrysotile 1,300SF
Brown VCT/mastic Misc Floors NF 8% Chrysotile 1,376SF
Tan VCT/mastic Misc Floors NF <1% Chrysotile 3,680SF
Carpet mastic Misc Floors NF Non-Detected N/A
Rubber Base/mastic Misc Floors NF Non-Detected N/A
Brick expansion joint Misc Exterior walls NF Non-Detected N/A
Asphalt shingles Misc Roof NF Non-Detected N/A
Based on the sample analysis, the following materials were found to be Asbestos Containing Materials:
Green VCT/mastic
Black VCT/mastic
Mastic under carpet with self-leveling compound
Transite wall panel in attic
Brown VCT/mastic
Tan VCT/mastic
Disposal
A. In accordance with the NCHHCU regulations, asbestos containing materials (ACM) waste should be taken to an approved landfill. All demolition/renovation work must be performed in accordance with NESHAP asbestos regulations, 40CFR61, Subpart M, and OSHA Regulations 29 CFR 1926.1101. Any disturbance should be conducted in accordance with federal, state, and local regulations.
Recommendations
A. Any demolition/renovation work in which ACM is disturbed must be in compliance with, EPA, OSHA and the state of North Carolina regulations.
Abatement work shall be conducted by NC Accredited asbestos workers under the supervision of a NC accredited asbestos supervisor. The contractor conducting asbestos abatement activities must notify the North Carolina Department of Health and Human Services (HHS) ten (10) days prior to the disturbance of ACM if it is friable and greater than or equal to 160 square feet, 260 linear feet or 35 cubic feet.
B. If additional suspect materials are discovered during demolition/renovation, they should be classified presumed to be asbestos-containing until sampling by a state of North Carolina licensed Asbestos Building Inspector personnel and analysis by a NVLAP-Accredited and state of North Carolina licensed laboratory can be performed.
See attached for Accreditations, Asbestos Lab Results and Chain of Custody. If further information is required, please contact me at 1-252-636-8778
Report Prepared by:
Christopher B. Walker North Carolina Asbestos Inspector Accreditation# 12878 The Walker Group Architecture, Inc., PO Box 541, New Bern, NC 28560
EMSL Analytical, Inc.
706 Gralin Street Kernersville, NC 27284
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / greensborolab@emsl.com
021800637EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 01/31/2018 1:00 PM
Analysis Date:New Bern, NC 28563 02/02/2018 - 02/05/2018
Collected Date: 01/24/2018
Project: Installation Reset FY18-Building 40
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
021800637-0001
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Exterior Door Caulk
021800637-0002
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Exterior Door Caulk
021800637-0003
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Exterior Window
Caulk
021800637-0004
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Exterior Window
Caulk
021800637-0005
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Cellulose<1%Gray/Tan/White
Non-Fibrous
Homogeneous
Cream W/ Blue
Specks VCT/Mastic
Composite result
021800637-0006
None DetectedQuartz
Non-fibrous (Other)
25%
75%
Cellulose<1%Gray/White/Yellow
Non-Fibrous
Heterogeneous
Cream W/ Blue
Specks VCT/Mastic
Composite result.
021800637-0007
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Gray/White
Fibrous
Heterogeneous
2x2 ACT
021800637-0008
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Gray/White
Fibrous
Homogeneous
2x2 ACT
021800637-0009
None DetectedNon-fibrous (Other)99%Cellulose
Fibrous (Other)
<1%
1%
Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0010
None DetectedNon-fibrous (Other)99%Cellulose
Fibrous (Other)
<1%
1%
Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0011
None DetectedNon-fibrous (Other)100%Cellulose
Fibrous (Other)
<1%
<1%
White/Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0012
None DetectedNon-fibrous (Other)99%Cellulose
Fibrous (Other)
<1%
1%
Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0013
None DetectedNon-fibrous (Other)99%Cellulose
Fibrous (Other)
<1%
1%
Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0014
None DetectedNon-fibrous (Other)100%Cellulose
Fibrous (Other)
<1%
<1%
White/Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0015
None DetectedNon-fibrous (Other)99%Cellulose
Fibrous (Other)
<1%
1%
Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
Initial report from: 02/05/2018 09:38:59
Page 1 of 3ASB_PLM_0008_0001 - 1.78 Printed: 2/5/2018 9:39 AM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / greensborolab@emsl.com
021800637EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
021800637-0016
None DetectedNon-fibrous (Other)99%Cellulose
Fibrous (Other)
<1%
1%
Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0017
None DetectedNon-fibrous (Other)99%Cellulose
Fibrous (Other)
<1%
1%
White/Beige
Non-Fibrous
Homogeneous
Spray Applied Texture on Concrete Corridor
Walls
021800637-0018
<1% ChrysotileQuartz
Non-fibrous (Other)
20%
80%
Tan/Black/Beige
Non-Fibrous
Homogeneous
Green VCT/Mastic
Composite result
021800637-0019
None DetectedQuartz
Non-fibrous (Other)
25%
75%
Cellulose<1%Tan/Black/Beige
Non-Fibrous
Heterogeneous
Green VCT/Mastic
Composite result.
021800637-0020
5% ChrysotileQuartz
Non-fibrous (Other)
10%
85%
Cellulose<1%Brown/Black
Non-Fibrous
Homogeneous
Black VCT/Mastic
Composite result
021800637-0021
Positive Stop (Not Analyzed)Black VCT/Mastic
021800637-0022
None DetectedNon-fibrous (Other)89%Cellulose
Glass
10%
1%
Brown/Gray
Fibrous
Heterogeneous
Gypsum/Joint
Compound
No joint compound present
021800637-0023
None DetectedNon-fibrous (Other)84%Cellulose
Glass
15%
1%
Brown/Gray
Fibrous
Heterogeneous
Gypsum/Joint
Compound
No Joint Compound Present.
021800637-0024
5% ChrysotileQuartz
Non-fibrous (Other)
10%
85%
Cellulose
Synthetic
<1%
<1%
Gray/Tan/Black
Non-Fibrous
Homogeneous
Mastic Under Carpet w/ Self-Leveling
Compound
Composite result
021800637-0025
Positive Stop (Not Analyzed)Mastic Under Carpet w/ Self-Leveling
Compound
021800637-0026
15% ChrysotileNon-fibrous (Other)85%Gray/White/Green
Non-Fibrous
Homogeneous
Transite Wall Panel in
Attic
021800637-0027
Positive Stop (Not Analyzed)Transite Wall Panel in
Attic
021800637-0028
8% ChrysotileQuartz
Non-fibrous (Other)
10%
82%
Cellulose<1%Brown/Gray/Black
Non-Fibrous
Homogeneous
Brown VCT/Mastic
Composite result
021800637-0029
Positive Stop (Not Analyzed)Brown VCT/Mastic
021800637-0030
<1% ChrysotileQuartz
Non-fibrous (Other)
20%
80%
Gray/White/Black
Non-Fibrous
Homogeneous
Tan VCT/Mastic
Composite result
021800637-0031
<1% ChrysotileQuartz
Non-fibrous (Other)
20%
80%
Cellulose
Synthetic
<1%
<1%
Black/Yellow/Beige
Non-Fibrous
Heterogeneous
Tan VCT/Mastic
Composite result.
Page 2 of 3ASB_PLM_0008_0001 - 1.78 Printed: 2/5/2018 9:39 AM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / greensborolab@emsl.com
021800637EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
021800637-0032
None DetectedNon-fibrous (Other)100%Cellulose
Synthetic
<1%
<1%
Beige
Non-Fibrous
Homogeneous
Carpet Mastic
021800637-0033
None DetectedNon-fibrous (Other)100%Cellulose
Synthetic
<1%
<1%
Beige
Non-Fibrous
Homogeneous
Carpet Mastic
021800637-0034
None DetectedNon-fibrous (Other)100%Cellulose<1%Beige
Non-Fibrous
Homogeneous
Rubber Base/Mastic
Composite result
021800637-0035
None DetectedNon-fibrous (Other)100%Cellulose<1%Yellow/Beige
Non-Fibrous
Heterogeneous
Rubber Base/Mastic
Composite result.
021800637-0036
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Brick Expansion Joint
021800637-0037
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Brick Expansion Joint
021800637-0038
None DetectedNon-fibrous (Other)92%Glass8%Black
Fibrous
Heterogeneous
Asphalt Shingles
021800637-0039
None DetectedNon-fibrous (Other)92%Cellulose
Glass
<1%
8%
Brown/Black
Fibrous
Heterogeneous
Asphalt Shingles
Analyst(s)
Nicole Shutts (21)
Scott Combs (14)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, CA ELAP 2689, Virginia 3333-000228, West Virginia LT000321
Page 3 of 3ASB_PLM_0008_0001 - 1.78 Printed: 2/5/2018 9:39 AM
SURVEY FINDINGS Building: 40
Friable ACM identified
Non-friable ACM identified DESCRIPTION LOCATION Date Quantity
DESCRIPTION LOCATION Date Quantity
No friable ACM records found in database
12" WHITE FLOOR TILE AND ADHESIVE 1,206 SFWEST WING AND CENTER HALLWAYS 1/19/2009
12" TAN FLOOR TILE AND ADHESIVE 3,680 SFWEST WING OFFICES 1/19/2009
RESIDUAL MASTIC 5,885 SFMIXED PATCHES THROUGHOUT
BUILDING (FROM PREVIOUS FLOORING)
1/19/2009
TRANSITE PANEL MATERIAL 1,300 SFATTIC FIREWALLS, CENTER 1/19/2009
12" GREEN FLOOR TILE AND ADHESIVE 1,396 SFTOP LAYER, MIXED USE THROUGHOUT
(OVER ACM TILE IN SOME LOCATIONS)
1/19/2009
9" BROWN FLOOR TILE AND ADHESIVE 1,376 SFMIXED USE THROUGHOUT, COMMONLY
UNDER HM100 GREEN TILE
1/19/2009
9" BLACK FLOOR TILE AND ADHESIVE 12 SFMECHANICAL ROOM #2 JANITORS
CLOSET (SEE ALSO HM113)
1/19/2009
EXTERIOR CAULKING, 294 LFDOOR PERIMETERS 1/19/2009
FLOOR TILE AND ADHESIVE, UNDER OTHER 1,280 SFEASTSIDE CORRIDOR UNDER HM101 (9"
BROWN) TILE (SEE ALSO HM106)
1/19/2009
12" TAN FLOOR TILE AND ADHESIVE 3,680 SFWEST WING OFFICES 8/6/2012
RESIDUAL MASTIC 5,885 SFMIXED PATCHES THROUGHOUT
BUILDING (FROM PREVIOUS FLOORING)
8/6/2012
9" BLACK FLOOR TILE AND ADHESIVE 12 SFMECHANICAL ROOM #2 JANITORS
CLOSET (SEE ALSO HM113)
8/6/2012
EXTERIOR CAULKING, 294 LFDOOR PERIMETERS 8/6/2012
FLOOR TILE AND ADHESIVE, UNDER OTHER 1,280 SFEASTSIDE CORRIDOR UNDER HM101 (9"
BROWN) TILE (SEE ALSO HM106)
8/6/2012
12" GREEN FLOOR TILE AND ADHESIVE 1,396 SFTOP LAYER, MIXED USE THROUGHOUT
(OVER ACM TILE IN SOME LOCATIONS)
8/6/2012
9" BROWN FLOOR TILE AND ADHESIVE 1,376 SFMIXED USE THROUGHOUT, COMMONLY
UNDER HM100 GREEN TILE
8/6/2012
TRANSITE PANEL MATERIAL 450 SFATTIC FIREWALL, CENTER 8/6/2012
Wednesday, April 26, 2017 Page 1 of 2
Tested Non ACM or REMOVED Materials DESCRIPTION LOCATION Date Quantity
12" WHITE FLOOR TILE AND ADHESIVE 1,206 SFWEST WING AND CENTER HALLWAYS 8/6/2012
TRANSITE PANEL MATERIAL 450 SFATTIC FIREWALLS, CENTER 10/20/2014
12" GREEN FLOOR TILE AND ADHESIVE 1,396 SFTOP LAYER, MIXED USE THROUGHOUT
(OVER ACM TILE IN SOME LOCATIONS)
10/20/2014
9" BROWN FLOOR TILE AND ADHESIVE 1,376 SFMIXED USE THROUGHOUT, COMMONLY
UNDER HM100 GREEN TILE
10/20/2014
12" WHITE FLOOR TILE AND ADHESIVE 1,206 SFWEST WING AND CENTER HALLWAYS 10/20/2014
12" TAN FLOOR TILE AND ADHESIVE 3,680 SFWEST WING OFFICES 10/20/2014
RESIDUAL MASTIC 5,885 SFMIXED PATCHES THROUGHOUT
BUILDING (FROM PREVIOUS FLOORING)
10/20/2014
9" BLACK FLOOR TILE AND ADHESIVE 12 SFMECHANICAL ROOM #2 JANITORS
CLOSET (SEE ALSO HM113)
10/20/2014
EXTERIOR CAULKING, 294 LFDOOR PERIMETERS 10/20/2014
FLOOR TILE AND ADHESIVE, UNDER OTHER 1,280 SFEASTSIDE CORRIDOR UNDER HM101 (9"
BROWN) TILE (SEE ALSO HM106)
10/20/2014
FLOOR LEVELING COMPOUND MIXED USE THROUGHOUT,
COMMONLY OVER ACM MASTIC
1/19/2009
ROOFING MATERIAL, ATTIC DEBRIS, NORTHEAST 1/19/2009
ROPE PACKING MATERIAL MAIN BOILER ROOM, SOUTHWEST 1/19/2009
PIPE INSULATION MAIN MECHANICAL/ BOILER ROOM
SOUTHWEST
1/19/2009
GASKET MATERIAL MAIN MECHANICAL/ BOILER ROOM
SOUTHWEST
1/19/2009
CLOTH EXPANSION JOINT MATERIAL, THIN ATTIC, CENTRAL MAIN SECTION WALL
(2 ABANDONED)
10/20/2014
SINK UNDERCOATING, CENTRAL KITCHEN AREA SINK 10/20/2014
12" TAN w/BROWN FLOOR TILE AND
ADHESIVE
EASTSIDE WING MECHANICAL ROOM
#4 (OVER ACM TILE)
1/19/2009
12" WHITE w/ GRAY FLOOR TILE AND
ADHESIVE
EASTSIDE OFFICES 1/19/2009
Wednesday, April 26, 2017 Page 2 of 2
CHECKED BY:
DRAWN BY:
SCALE: GRAPHIC
SHEET OF
DATE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
A H
E n v i r o n m e n t a l
C o n s u l t a n t s
S Y
M
A P
P R
O V
E D
D A
T E
M C
B
C
A M
P
L E
J E
U N
E
N
C
01-01 (+,-)
SAMPLE IDENTIFICATION
HOMOGENOUS MATERIAL
POSITIVE (+), NEGATIVE (-), OR TRACE
(TR) FOR THE PRESENCE OF ASBESTOS
SAMPLE LEGEND ID
BUILDING 40
FIRST FLOOR
C Y
A
S B
E S
T O
S
I N
S P
E C
T I O
N
M C
B
C
A M
P
L E
J E
U E
N E
N
C
DD
ARD
OCTOBER 2014
1 2
0'0'0'0'14' 28' 14'
56'
ACM LEGEND
MASTIC UNDER 12" GREEN [HM100] 12" TAN
MASTIC RESIDUE [HM104, 105, 106, 112]
9" BROWN [HM101], 12" WHITE W/ BLUE [HM102]
9" BROWN FLOOR TILE [HM14]
FLOOR TILE UNDER OTHER, BLACK AND MASTIC
[HM113]
[HM103], 12" WHITE W/ GRAY [HM114]
FLOOR TILE AND MASTIC
EXTERIOR CAULKING, DOOR, WHITE, RESIDUAL [HM111]
C CARPET
MR MECHANICAL ROOM
A ATTIC ACCESS
[HM] HOMOGENOUS MATERIAL NUMBER
HT HARD TILE
NAX NOT ACCESSIBLE
IP
AN
INFORMATION PACKET
ASBESTOS NOTIFICATION
ELECTRICAL PANEL
CHECKED BY:
DRAWN BY:
SCALE: GRAPHIC
SHEET OF
DATE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
A H
E n v i r o n m e n t a l
C o n s u l t a n t s
S Y
M
A P
P R
O V
E D
D A
T E
M C
B
C
A M
P
L E
J E
U N
E
N
C
01-01 (+,-)
SAMPLE IDENTIFICATION
HOMOGENOUS MATERIAL
POSITIVE (+), NEGATIVE (-), OR TRACE
(TR) FOR THE PRESENCE OF ASBESTOS
SAMPLE LEGEND ID
BUILDING 40
ATTIC
C Y
A
S B
E S
T O
S
I N
S P
E C
T I O
N
A
M C
B
C
A M
P
L E
J E
U E
N E
N
C
DD
ARD
OCTOBER 2014
2 2
0'0'0'0'14' 28' 14'
56'
ACM LEGEND
TRANSITE PANEL MATERIAL AND DEBRIS (FIREWALL) [HM15]
A ATTIC ACCESS
File details come from the government source that posted it. Updated .