This lead paint survey report details the findings of an inspection conducted at various buildings slated for demolition at Marine Corps Base Camp Lejeune. Paint chip samples were collected from surfaces coated with different colors at Buildings 40, 11, 26, 39, 113, 116, 117, 117A, 216, 229, 424, 432, 435, 436, 512, 521, 531, 738, 797, 798, 799, 812, 812A, 824, 911, 1010, 1728, 1742, 1909, 1933, 2043, 2626, 2627, 2627, BB54, BB246, FC127, FC130, FC250A, FC250B, FC250C, FC260, FC318, FC416, FC416A, G699, H48, LCH4011, LCH4012, LCH4012A, LCH4012B, LCH4038, M151A, M151B, M151C, M151D, M225, M226, M227, M228, M229, M232, M236, M305, M441, PT6, RR95, S1934, S1972, S1973, S1976, S1980, S1981, S1983, SA42, SG648, STC911, SVL328, TC760, TC761, TC762, TC804, TC806, TC807, TC817, TC829, TC836, TC838, TC839, TC942, TC1004, TC1006, TC1019, TC1026, TC1027, TC1060, TC1061, TC1062, TC1063, TC1143, and VL331. The related federal contract opportunity is for the demolition of various buildings at Marine Corps Base Camp Lejeune according to the plans and specifications, under solicitation number N4008521B2504.

View the file

Other files for this federal contract opportunity

Other files attached to Infrastructure Reset Demo Buildings - Package B, newest first.
File Type Posted
N4008521B2504 Amendment08.pdf PDF
N4008521B2505 Amendment08.pdf PDF
EMD Decision Memorandum.pdf PDF
N4008521B2504 Amendment07.pdf PDF
N4008521B2504 Amendment06.pdf PDF
Building 40 Asbestos Survey.pdf PDF
Building 40 Demo Plans.pdf PDF
Amended Section 02 82 16 Removal of Asbestos Materials.pdf PDF
N4008521B2504 Amendment05.pdf PDF
N4008521B2504 Amendment04.pdf PDF
N4008521B2504 Amendment03.pdf PDF
Contractor_Environmental_Guide.pdf PDF
N4008521B2504 Amendment02.pdf PDF
N4008521B2504 Amendment01.pdf PDF
N4008521B2504LeadSurveyReport.pdf PDF
N4008521B2504Dwgs.pdf PDF
N4008521B2504AsbestosSurveyReport.pdf PDF
N4008521B2504Solicitation.pdf PDF
N4008521B2504Specs.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lead Paint Survey Demolish Various Building FY18 at MCB Camp Lejeune (Phase 2)

Demolish Various Buildings at MCB Camp Lejeune (Phase 2) Marine Corps Base Camp Lejeune

Project # 17-0072

Report Prepared By:

Christopher B. Walker

The Walker Group Architecture, Inc May 31, 2018

WGA Project No. – 1740.IR18

Project Information

The Walker Group Architecture, Inc. was contracted by Camp Lejeune to conduct an asbestos sampling survey for Buildings/Structures 11, 26, 39, 40, 113, 116, 117, 117A, 216, 229, 424, 432, 435, 436, 512, 521, 531, 738, 797, 798, 799, 812, 812A, 824, 911, 1010, 1728, 1742, 1909, 1933, 2043, 2626, 2627, 2627, BB54, BB246, FC127, FC130, FC250A, FC250B, FC250C, FC260, FC318, FC416, FC416A, G699, H48, LCH4011, LCH4012, LCH4012A, LCH4012B, LCH4038, M151A, M151B, M151C, M151D, M225, M226, M227, M228, M229, M232, M236, M305, M441, PT6, RR95, S1934, S1972, S1973, S1976, S1980, S1981, S1983, SA42, SG648, STC911, SVL328, TC760, TC761, TC762, TC804, TC806, TC807, TC817, TC829, TC836, TC838, TC839, TC942, TC1004, TC1006, TC1019, TC1026, TC1027, TC1060, TC1061, TC1062, TC1063, TC1143, and VL331.

Buildings or structures LCH4030, S1971, S1986, S1918, SBB108, SRR57, SRR58, SVL335. The specified buildings or structures are slated for demolition on board Marine Corps Base Camp Lejeune. The survey was conducted to determine if building components were coated with lead-based paint.

Scope of Services

A. The survey was performed on January 24th, February 2nd, February 8th, February 17th, March 1st, March 11th, March 16-17th, March 23rd, March 28th, and April 19, 2018, by Christopher B. Walker (NC Accredited Lead Inspector #110239 expires March 31, 2019. Samples were collected from areas defined by the scope of work.

Findings

A. The Walker Group Architecture collected paint chip samples from each surface visibly coated with a different color of paint and delivered them to EMSL Analytical, Inc. (AIHA ELLAP lab code no. 102564) for analysis for lead content by Flame AAS (SW 846 3050B*/7420) in accordance with EPA 3050B/Modified/7000B. OSHA 29 CFR

1926.62 defines any detectable level of lead in paint a concern when renovations/demolitions will impact lead coated surfaces.

B. The detection limit is determined by weight of the sample, which is typically 0.01%.

See attached Lab Results for additional information.

Building 40

Building Description and Findings (Inspected 01-24-18)

Building 40 is a family services center. The building exterior is brick and the roof consists asphalt shingles. Interior walls are gypsum board, cmu, and the ceilings are drop down acoustical ceiling tile. (8) samples were taken for analysis.

Laboratory Results

Suspect Material Sampled Location Condition Concentration % by Weight

Tan wood door frames, window sills, base board Interior Intact 0.15%

White Concrete Walls Interior Intact 0.46%

White Exterior wood, door, fascia, ceilings Exterior Intact 0.77%

Exterior white storefront at breezeway Exterior Intact <0.010%

Based on the sample analysis, the following coatings should be considered Lead Based Paint.

Tan wood door frames, window sills, base board

White Concrete Walls

White Exterior wood, door, fascia, ceilings

Recommendations

A. Any demolition/renovation work in which lead coated surfaces are disturbed must be in compliance with all Federal, State, and Local regulations. All work should be conducted by workers trained in "lead safe practices" as outlined by

OSHA.

B. If additional suspect materials are discovered during demolition/renovation, they should be classified presumed to contain lead based paint until sampling by a state of North Carolina licensed Lead Inspector personnel and analysis by an Accredited and state of North Carolina licensed laboratory can be performed.

See attached for Plan Locations, Lead Laboratory Results, and Chain of Custody.

If further information is required, please contact me at 1-252-636-8778

Report Prepared by:

Christopher B. Walker North Carolina Lead Inspector Accreditation# 110239 The Walker Group Architecture, Inc.

PO Box 541 New Bern, NC 28560

ConcentrationAnalyzed Reporting Detection LimitLab ID: LeadCollected

Attn: Chris Walker

The Walker Group Architecture

PO Box 541

New Bern, NC 28563

Received: 01/31/18 1:00 PM

Installation Reset FY18-Building 40

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

1/24/2018Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284

Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

021800624 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

0.15 % wt2/2/2018021800624-0001 0.010

Client Sample 1/24/2018

Pb-01

% wt

0.099 % wt2/2/2018021800624-0002 0.010

Client Sample 1/24/2018

Pb-02

% wt

0.46 % wt2/2/2018021800624-0003 0.10

Client Sample 1/24/2018

Pb-03

% wt

0.46 % wt2/2/2018021800624-0004 0.10

Client Sample 1/24/2018

Pb-04

% wt

0.019 % wt2/2/2018021800624-0005 0.010

Client Sample 1/24/2018

Pb-05

% wt

0.77 % wt2/2/2018021800624-0006 0.10

Client Sample 1/24/2018

Pb-06

% wt

<0.010 % wt2/2/2018021800624-0007 0.010

Client Sample 1/24/2018

Pb-07

% wt

<0.010 % wt2/2/2018021800624-0008 0.010

Client Sample 1/24/2018

Pb-08

% wt

Page 1 of 2Test Report PB w/RD/I-7.32.3 Printed: 2/2/2018 2:51:26 PM

James Cole, Laboratory Manager or other approved signatory

*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.

Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 02/02/2018 14:51:26 http://www.EMSL.com mailto:greensborolab@emsl.com

ConcentrationAnalyzed Reporting Detection LimitLab ID: LeadCollected

Attn: Chris Walker

The Walker Group Architecture

PO Box 541

New Bern, NC 28563

Received: 01/31/18 1:00 PM

Installation Reset FY18-Building 40

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

1/24/2018Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284

Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

021800624 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

Guidelines for Federal USEPA/HUD Lead in Paint Chips

=0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.

Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint

Below Method Reporting Limit (RL)

These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.

Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.

No responsibility or liability is assumed for the manner in which the results are used or interpreted.

Page 2 of 2Test Report PB w/RD/I-7.32.3 Printed: 2/2/2018 2:51:26 PM

James Cole, Laboratory Manager or other approved signatory

*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.

Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 02/02/2018 14:51:26 http://www.EMSL.com mailto:greensborolab@emsl.com