The file's text, extracted by GovTribe without its formatting.
Recurring Work Base Option
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE OF ABOVE GROUND STORAGN TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE |
| CENTER, NEWPORT, RHODE ISLAND |
| CLIN 0001 - BASE OPTION PERIOD - SCHEDULE OF FIRM-FIXED-PRICE WORK | | | | | |
| ELINS A001 - A006 | | | | |
| | | Unit | | |
| Item | | | of | Unit | |
| No. | Supplies/Services | Quantity | Issue | Price | Total |
| A001 - CNIC (NAVSTA) AST | | | | | |
| A001A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A001B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| A001C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1 | 35 | EA | $ - 0 | $ - 0 |
| A001D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 27 | EA | $ - 0 | $ - 0 |
| A001E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 6 | EA | $ - 0 | $ - 0 |
| A001F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| A001G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| A001H | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 - 300,00 Gal. Spec 3.2.1.1 | 0 | EA | $ - 0 | $ - 0 |
| A001J | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| | | NAVSTA AST Total | | $ - 0 |
| A001B - CNIC (NAVSTA) UST | | | | | |
| A001BA | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A001BB | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| A001BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| A001BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.2 | 4 | EA | $ - 0 | $ - 0 |
| A001BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 40 | EA | $ - 0 | $ - 0 |
| | | NAVSTA UST Total | | $ - 0 |
| NAVSTA TOTAL | | | | $ - 0 |
| A002 NAVFAC CNIC/UEM AST | | | | | |
| A002A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A002B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| A002C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 13 | EA | $ - 0 | $ - 0 |
| A002D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 7 | EA | $ - 0 | $ - 0 |
| A002E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1000 Gal. - 2500 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| A002F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 Gal. - 281,386 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| A002G | Hazardous Waste Disposal Estimated AST Spec 3.3 | 5 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM AST Total | | $ - 0 |
| A002B NAVFAC CNIC/UEM UST | | | | | |
| A002BA | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| A002BB | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| A002BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| A002BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| A002BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 20 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM UST Total | | $ - 0 |
| NAVFAC UEM TOTAL | | | | $ - 0 |
| A003 NHCNE AST | | | | | |
| A003A | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| A003B | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| A003C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| A003D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| A003E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| | | NCHNE UEM AST Total | | $ - 0 |
| A003B NHCNE UST | | | | | |
| A003BA | Routine Service Work Order Spec 3.1.1 | 2 | EA | $ - 0 | $ - 0 |
| A003BB | Emergency Service Orders Spec 3.1.2 | 2 | EA | $ - 0 | $ - 0 |
| A003BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| A003BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| A003BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NHCNE Subtotal | | NCHNE UEM UST Total | | $ - 0 |
| | | NCHNE TOTAL | | $ - 0 |
| A004 NUWC AST | | | | | |
| A004A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A004B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| A004C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 20 | EA | $ - 0 | $ - 0 |
| A004D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 16 | EA | $ - 0 | $ - 0 |
| A004E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| A004F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| A004G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| A004H | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| NUWC Subtotal | | | | $ - 0 |
| A005 NGIS AST | | | | | |
| A005A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A005B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| A005C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| A005D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| A005E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NGIS Subtotal | | | | $ - 0 |
| A006 NEX UST | | | | | |
| A006A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A006B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| A006C | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A006D | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| A006E | Hazardous Waste Disposal Estimated UST Spec 3.3 | 8 | GL | $ - 0 | $ - 0 |
| NEX Subtotal | | | | $ - 0 |
BASE TOTAL $ - 0
Base Option IDIQ
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE AND REPAIR OF ABOVE GROUND STORAGE TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE CENTER, |
| NEWPORT RHODE ISLAND AND OTHER AREAS OF RESPONSIBILITY |
CLIN 0002 - BASE OPTION PERIOD - SCHEDULE OF INDEFINITE QUANTITY WORK
Item No. Supplies/Services Quantity Unit of issue Unit Price Total Amount
| A700 | Pump sumps and spill containers of hazardous materials as indicated in Annex 3.1.2 | 500 | GL | $ - 0 | $ - 0 |
| A701 | Removal/Installation of Veeder Root Systems | 30 | EA | $ - 0 | $ - 0 |
| A702 | Tank Vents | | | | |
| A702A | Tank Vents 2" | 10 | EA | $ - 0 | $ - 0 |
| A702B | Tank Vents 3" | 10 | EA | $ - 0 | $ - 0 |
| A702C | Tank Vents 4" | 10 | EA | $ - 0 | $ - 0 |
| A702D | Tank Vents 6" | 10 | EA | $ - 0 | $ - 0 |
| A703 | Provide labor to perform all Unit Priced Labor Work subject to the Service Contract Act per the scope and delivery schedule specified in the order. Must be negotiated by KO using ETO process. | 1000 | HR | $ - 0 | $ - 0 |
| A704 | Provide all materials and equipment (not listed on IDIQ ELINS) on to perform Unit Priced Labor work per the scope and delivery schedule specified in the order. Use ELIN A702. These material costs must be negotiated by KO using ETO process. | 1 | LT | $ - 0 | $ - 0 |
Total IQ Line Items A700 through A704 $ - 0
BASE OPTION YEAR TOTAL
Recurring Work Option 1
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE OF ABOVE GROUND STORAGN TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE |
| CENTER, NEWPORT, RHODE ISLAND |
| CLIN 0003 - FIRST OPTION PERIOD - SCHEDULE OF FIRM-FIXED-PRICE WORK | | | | | |
| ELINS B001 - B006 | | | | |
| | | Unit | | |
| Item | | | of | Unit | |
| No. | Supplies/Services | Quantity | Issue | Price | Total |
| B001 - CNIC (NAVSTA) AST | | | | | |
| B001A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| B001B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| B001C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1 | 35 | EA | $ - 0 | $ - 0 |
| B001D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 27 | EA | $ - 0 | $ - 0 |
| B001E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 6 | EA | $ - 0 | $ - 0 |
| B001F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| B001G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| B001H | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 - 300,00 Gal. Spec 3.2.1.1 | 0 | EA | $ - 0 | $ - 0 |
| B001J | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| | | NAVSTA AST Total | | $ - 0 |
| B001B - CNIC (NAVSTA) UST | | | | | |
| B001BA | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| B001BB | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| B001BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| B001BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.2 | 4 | EA | $ - 0 | $ - 0 |
| B001BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 40 | EA | $ - 0 | $ - 0 |
| | | NAVSTA UST Total | | $ - 0 |
| NAVSTA TOTAL | | | | $ - 0 |
| B002 NAVFAC CNIC/UEM AST | | | | | |
| B002A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| B002B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| B002C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 13 | EA | $ - 0 | $ - 0 |
| B002D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 7 | EA | $ - 0 | $ - 0 |
| B002E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1000 Gal. - 2500 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 Gal. - 281,386 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| B002E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 5 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM AST Total | | $ - 0 |
| B002B NAVFAC CNIC/UEM UST | | | | | |
| B002BA | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| B002BB | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| B002BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| B002BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| B002BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 20 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM UST Total | | $ - 0 |
| NAVFAC UEM TOTAL | | | | $ - 0 |
| B003 NHCNE AST | | | | | |
| B003A | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| B003B | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| B003C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| B003D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| B003E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| | | NCHNE UEM AST Total | | $ - 0 |
| B003B NHCNE UST | | | | | |
| B003BA | Routine Service Work Order Spec 3.1.1 | 2 | EA | $ - 0 | $ - 0 |
| B003BB | Emergency Service Orders Spec 3.1.2 | 2 | EA | $ - 0 | $ - 0 |
| B003BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| B003BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| B003BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NHCNE Subtotal | | NCHNE UEM UST Total | | $ - 0 |
| | | NCHNE TOTAL | | $ - 0 |
| B004 NUWC AST | | | | | |
| B004A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| B004B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| B004C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 20 | EA | $ - 0 | $ - 0 |
| B004D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 16 | EA | $ - 0 | $ - 0 |
| B004E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| B004F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| B004G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| B004H | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| NUWC Subtotal | | | | $ - 0 |
| B005 NGIS AST | | | | | |
| B005A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| B005B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| B005C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| B005D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| B005E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NGIS Subtotal | | | | $ - 0 |
| | | | | | 0 |
| B006 NEX UST | | | | | | |
| B006A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 | |
| B006B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 | |
| B006C | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 | |
| B006D | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 | |
| B006E | Hazardous Waste Disposal Estimated UST Spec 3.3 | 8 | GL | $ - 0 | $ - 0 | |
| NEX Subtotal | | | | $ - 0 | |
BASE TOTAL $ - 0
IDIQ Option 1
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE AND REPAIR OF ABOVE GROUND STORAGE TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE CENTER, |
| NEWPORT RHODE ISLAND AND OTHER AREAS OF RESPONSIBILITY |
CLIN 004 - FIRST OPTION PERIOD - SCHEDULE OF INDEFINITE QUANTITY WORK
Item No. Supplies/Services Unit of issue Unit Price Total Amount Price Amount
| B700 | Pump sumps ans spill containers of hazardous materials | 2 | GL | $ - 0 | $ - 0 |
| as indicated in Annex 3.1.2 | 5500 | | | |
| B701 | Removal/Installation of Veeder Root Systems | 30 | EA | $ - 0 | $ - 0 |
| B702 | Tank Vents | 102 | | | |
| B702A | 2" | 117 | EA | $ - 0 | $ - 0 |
| B702B | 3" | 146 | EA | $ - 0 | $ - 0 |
| B702C | 4" | 208 | EA | $ - 0 | $ - 0 |
| B702D | Provide labor to perform all Unit Priced Labor Work subject to the Service Contract Act per the scope and delivery schedule specified in the order. Must be negotiated by KO using ETO process. | 1 | EA | $ - 0 | $ - 0 |
| Provide all materials and equipment (not listed on IDIQ ELINS) on to perform Unit Priced Labor work per the scope and delivery schedule specified in the order. Use ELIN A702. These material costs must be negotiated by KO using ETO process. | | | | |
Total IQ Line Items B700 through B704 $ - 0
FIRST OPTION YEAR TOTAL
Recurring Work Option 2
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE OF ABOVE GROUND STORAGN TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE |
| CENTER, NEWPORT, RHODE ISLAND |
| CLIN 0005 - SECOND OPTION PERIOD - SCHEDULE OF FIRM-FIXED-PRICE WORK | | | | | |
| ELINS C001 - C006 | | | | |
| | | Unit | | |
| Item | | | of | Unit | |
| No. | Supplies/Services | Quantity | Issue | Price | Total |
| C001- CNIC (NAVSTA) AST | | | | | |
| C001A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C001B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| C001C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1 | 35 | EA | $ - 0 | $ - 0 |
| C001D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 27 | EA | $ - 0 | $ - 0 |
| C001D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 6 | EA | $ - 0 | $ - 0 |
| C001E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| C001F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| C001G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 - 300,00 Gal. Spec 3.2.1.1 | 0 | EA | $ - 0 | $ - 0 |
| C001H | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| | | NAVSTA AST Total | | $ - 0 |
| C001B - CNIC (NAVSTA) UST | | | | | |
| C001B | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C001C | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| C001D | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| C001E | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.2 | 4 | EA | $ - 0 | $ - 0 |
| C001F | Hazardous Waste Disposal Estimated UST Spec 3.3 | 40 | EA | $ - 0 | $ - 0 |
| | | NAVSTA UST Total | | $ - 0 |
| NAVSTA TOTAL | | | | $ - 0 |
| C002 NAVFAC CNIC/UEM AST | | | | | |
| C002A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C002B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| C002C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 13 | EA | $ - 0 | $ - 0 |
| C002D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 7 | EA | $ - 0 | $ - 0 |
| C002C | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1000 Gal. - 2500 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| C002D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 Gal. - 281,386 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| C002E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 5 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM AST Total | | $ - 0 |
| C002B NAVFAC CNIC/UEM UST | | | | | |
| C002BA | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| C002BB | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| C002BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| C002BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| B002BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 20 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM UST Total | | $ - 0 |
| NAVFAC UEM TOTAL | | | | $ - 0 |
| C003 NHCNE AST | | | | | |
| C003A | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| C003B | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| C003C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| C003D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| C003E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| | | NCHNE UEM AST Total | | $ - 0 |
| C003B NHCNE UST | | | | | |
| C003BA | Routine Service Work Order Spec 3.1.1 | 2 | EA | $ - 0 | $ - 0 |
| C003BB | Emergency Service Orders Spec 3.1.2 | 2 | EA | $ - 0 | $ - 0 |
| C003BC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| C003BD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| C003BE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NHCNE Subtotal | | NCHNE UEM UST Total | | $ - 0 |
| | | NCHNE TOTAL | | $ - 0 |
| C004 NUWC AST | | | | | |
| C004A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C004B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| C004C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 20 | EA | $ - 0 | $ - 0 |
| C004D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 16 | EA | $ - 0 | $ - 0 |
| C004E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| C004F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| C004G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| C004H | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| NUWC Subtotal | | | | $ - 0 |
| C005 NGIS AST | | | | | |
| C005A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C005B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| C005C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| C005D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| C005E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NGIS Subtotal | | | | $ - 0 |
| C006 NEX UST | | | | | |
| C006A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C006B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| C006C | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C006D | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| C006E | Hazardous Waste Disposal Estimated UST Spec 3.3 | 8 | GL | $ - 0 | $ - 0 |
| NEX Subtotal | | | | $ - 0 |
BASE TOTAL $ - 0
IDIQ Option 2
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE AND REPAIR OF ABOVE GROUND STORAGE TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE CENTER, |
| NEWPORT RHODE ISLAND AND OTHER AREAS OF RESPONSIBILITY |
CLIN 0006 - SECOND OPTION PERIOD - SCHEDULE OF INDEFINITE QUANTITY WORK
Item No. Supplies/Services Unit of issue Unit Price Total Amount Price Amount
| C700 | Pump sumps ans spill containers of hazardous materials | 2 | GL | $ - 0 | $ - 0 |
| as indicated in Annex 3.1.2 | 5500 | | | |
| C701 | Removal/Installation of Veeder Root Systems | 30 | EA | $ - 0 | $ - 0 |
| C702 | Tank Vents | 102 | | | |
| C702A | 2" | 117 | EA | $ - 0 | $ - 0 |
| C702B | 3" | 146 | EA | $ - 0 | $ - 0 |
| C702C | 4" | 208 | EA | $ - 0 | $ - 0 |
| C702D | Provide labor to perform all Unit Priced Labor Work subject to the Service Contract Act per the scope and delivery schedule specified in the order. Must be negotiated by KO using ETO process. | 1 | EA | $ - 0 | $ - 0 |
| Provide all materials and equipment (not listed on IDIQ ELINS) on to perform Unit Priced Labor work per the scope and delivery schedule specified in the order. Use ELIN A702. These material costs must be negotiated by KO using ETO process. | | | | |
Total IQ Line Items C700 through C704 $ - 0
SECOND OPTION YEAR TOTAL
Recurring Work Option 3
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE OF ADOVE GROUND STORAGN TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE |
| CENTER, NEWPORT, RHODE ISLAND |
| CLIN 0007 - THIRD OPTION PERIOD - SCHEDULE OF FIRM-FIXED-PRICE WORK | | | | | |
| ELINS D001 - D006 | | | | |
| | | Unit | | |
| Item | | | of | Unit | |
| No. | Supplies/Services | Quantity | Issue | Price | Total |
| D001 - CNIC (NAVSTA) AST | | | | | |
| D001A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D001B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| D001C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1 | 35 | EA | $ - 0 | $ - 0 |
| D001D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 27 | EA | $ - 0 | $ - 0 |
| D001E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 6 | EA | $ - 0 | $ - 0 |
| D001F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| D001G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| D001H | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 - 300,00 Gal. Spec 3.2.1.1 | 0 | EA | $ - 0 | $ - 0 |
| D001J | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| | | NAVSTA AST Total | | $ - 0 |
| D001A - CNIC (NAVSTA) UST | | | | | |
| D001AA | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D001AB | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| D001AC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| D001AD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.2 | 4 | EA | $ - 0 | $ - 0 |
| D001AE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 40 | EA | $ - 0 | $ - 0 |
| | | NAVSTA UST Total | | $ - 0 |
| NAVSTA TOTAL | | | | $ - 0 |
| D002 NAVFAC CNIC/UEM AST | | | | | |
| D002A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D002B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| D002C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 13 | EA | $ - 0 | $ - 0 |
| D002D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 7 | EA | $ - 0 | $ - 0 |
| D002E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1000 Gal. - 2500 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| D002F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 Gal. - 281,386 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| D002G | Hazardous Waste Disposal Estimated AST Spec 3.3 | 5 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM AST Total | | $ - 0 |
| D002A NAVFAC CNIC/UEM UST | | | | | |
| D002AA | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| D002AB | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| D002AC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| D002AD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| D002AE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 20 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM UST Total | | $ - 0 |
| NAVFAC UEM TOTAL | | | | $ - 0 |
| D003 NHCNE AST | | | | | |
| D003A | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| D003B | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| D003C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| D003D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| D003E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| | | NCHNE UEM AST Total | | $ - 0 |
| D003A NHCNE UST | | | | | |
| D003AA | Routine Service Work Order Spec 3.1.1 | 2 | EA | $ - 0 | $ - 0 |
| D003AB | Emergency Service Orders Spec 3.1.2 | 2 | EA | $ - 0 | $ - 0 |
| D003AC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| D003AD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| D003AE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NHCNE SuDtotal | | NCHNE UEM UST Total | | $ - 0 |
| | | NCHNE TOTAL | | $ - 0 |
| D004 NUWC AST | | | | | |
| D004A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D004B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| D004C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 20 | EA | $ - 0 | $ - 0 |
| D004D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 16 | EA | $ - 0 | $ - 0 |
| D004E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| D004F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| D004G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| D004H | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| NUWC SuDtotal | | | | $ - 0 |
| D005 NGIS AST | | | | | |
| D005A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D005B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| D005C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| D005D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| D005E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NGIS SuDtotal | | | | $ - 0 |
| D006 NEX UST | | | | | |
| D006A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D006B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| D006C | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D006D | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| D006E | Hazardous Waste Disposal Estimated UST Spec 3.3 | 8 | GL | $ - 0 | $ - 0 |
| NEX SuDtotal | | | | $ - 0 |
DASE TOTAL $ - 0
IDIQ Option 3
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE AND REPAIR OF ABOVE GROUND STORAGE TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE CENTER, |
| NEWPORT RHODE ISLAND AND OTHER AREAS OF RESPONSIBILITY |
CLIN 0008 - THIRD OPTION PERIOD - SCHEDULE OF INDEFINITE QUANTITY WORK
Item No. Supplies/Services Unit of issue Unit Price Total Amount Price Amount
| D700 | Pump sumps ans spill containers of hazardous materials | 2 | GL | $ - 0 | $ - 0 |
| as indicated in Annex 3.1.2 | 5500 | | | |
| D701 | Removal/Installation of Veeder Root Systems | 30 | EA | $ - 0 | $ - 0 |
| D702 | Tank Vents | 102 | | | |
| D702A | 2" | 117 | EA | $ - 0 | $ - 0 |
| D702B | 3" | 146 | EA | $ - 0 | $ - 0 |
| D702C | 4" | 208 | EA | $ - 0 | $ - 0 |
| D702D | Provide labor to perform all Unit Priced Labor Work subject to the Service Contract Act per the scope and delivery schedule specified in the order. Must be negotiated by KO using ETO process. | 1 | EA | $ - 0 | $ - 0 |
| Provide all materials and equipment (not listed on IDIQ ELINS) on to perform Unit Priced Labor work per the scope and delivery schedule specified in the order. Use ELIN A702. These material costs must be negotiated by KO using ETO process. | | | | |
Total IQ Line Items D700 through D704 $ - 0
THIRD OPTION YEAR TOTAL
Recurring Work Option 4
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE OF ABOVE GROUND STORAGN TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE |
| CENTER, NEWPORT, RHODE ISLAND |
| CLIN 0009 - FOURTH OPTION PERIOD - SCHEDULE OF FIRM-FIXED-PRICE WORK | | | | | |
| ELINS E001 - E006 | | | | |
| | | Unit | | |
| Item | | | of | Unit | |
| No. | Supplies/Services | Quantity | Issue | Price | Total |
| E001 - CNIC (NAVSTA) AST | | | | | |
| E001A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E001B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| E001C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1 | 35 | EA | $ - 0 | $ - 0 |
| E001D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 27 | EA | $ - 0 | $ - 0 |
| E001E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 6 | EA | $ - 0 | $ - 0 |
| E001F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| E001G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| E001H | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 - 300,00 Gal. Spec 3.2.1.1 | 0 | EA | $ - 0 | $ - 0 |
| E001J | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| | | NAVSTA AST Total | | $ - 0 |
| E001A - CNIC (NAVSTA) UST | | | | | |
| E001AA | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E001AB | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| E001AC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| E001AD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.2 | 4 | EA | $ - 0 | $ - 0 |
| E001AE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 40 | EA | $ - 0 | $ - 0 |
| | | NAVSTA UST Total | | $ - 0 |
| NAVSTA TOTAL | | | | $ - 0 |
| E002 NAVFAC CNIC/UEM AST | | | | | |
| E002A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E002B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| E002C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 13 | EA | $ - 0 | $ - 0 |
| E002D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 7 | EA | $ - 0 | $ - 0 |
| E002E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1000 Gal. - 2500 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| E002F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 10,000 Gal. - 281,386 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| E002G | Hazardous Waste Disposal Estimated AST Spec 3.3 | 5 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM AST Total | | $ - 0 |
| E002A NAVFAC CNIC/UEM UST | | | | | |
| E002AA | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| E002AB | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| E002AC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| E002AD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 23 | EA | $ - 0 | $ - 0 |
| E002AE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 20 | GL | $ - 0 | $ - 0 |
| | | NAVFAC UEM UST Total | | $ - 0 |
| NAVFAC UEM TOTAL | | | | $ - 0 |
| E003 NHCNE AST | | | | | |
| E003A | Routine Service Work Order Spec 3.1.1 | 3 | EA | $ - 0 | $ - 0 |
| E003B | Emergency Service Orders Spec 3.1.2 | 3 | EA | $ - 0 | $ - 0 |
| E003C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| E003D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| E003E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| | | NCHNE UEM AST Total | | $ - 0 |
| E003A NHCNE UST | | | | | |
| E003AA | Routine Service Work Order Spec 3.1.1 | 2 | EA | $ - 0 | $ - 0 |
| E003AB | Emergency Service Orders Spec 3.1.2 | 2 | EA | $ - 0 | $ - 0 |
| E003AC | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| E003AD | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| E003AE | Hazardous Waste Disposal Estimated UST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NHCNE SuDtotal | | NCHNE UEM UST Total | | $ - 0 |
| | | NCHNE TOTAL | | $ - 0 |
| E004 NUWC AST | | | | | |
| E004A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E004B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| E004C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 20 | EA | $ - 0 | $ - 0 |
| E004D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 16 | EA | $ - 0 | $ - 0 |
| E004E | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 1,000-2,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| E004F | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 2,500-4,000 Gal. Spec 3.2.1.1 | 1 | EA | $ - 0 | $ - 0 |
| E004G | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 6,000-10,000 Gal. Spec 3.2.1.1 | 2 | EA | $ - 0 | $ - 0 |
| E004H | Hazardous Waste Disposal Estimated AST Spec 3.3 | 50 | GL | $ - 0 | $ - 0 |
| NUWC SuDtotal | | | | $ - 0 |
| E005 NGIS AST | | | | | |
| E005A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E005B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| E005C | Develop And Implement Preventive Maintenance Program For AST Monthly Inspections Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| E005D | Develop And Implement Preventive Maintenance Program For AST Yearly Inspections 50 Gal. - 900 Gal. Spec 3.2.1.1 | 4 | EA | $ - 0 | $ - 0 |
| E005E | Hazardous Waste Disposal Estimated AST Spec 3.3 | 10 | GL | $ - 0 | $ - 0 |
| NGIS SuDtotal | | | | $ - 0 |
| E006 NEX UST | | | | | |
| E006A | Routine Service Work Order Spec 3.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E006B | Emergency Service Orders Spec 3.1.2 | 5 | EA | $ - 0 | $ - 0 |
| E006C | Develop And Implement Preventive Maintenance Program For UST Monthly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E006D | Develop And Implement Preventive Maintenance Program For UST Yearly Inspections Spec 3.2.1.1 | 5 | EA | $ - 0 | $ - 0 |
| E006E | Hazardous Waste Disposal Estimated UST Spec 3.3 | 8 | GL | $ - 0 | $ - 0 |
| NEX SuDtotal | | | | $ - 0 |
DASE TOTAL $ - 0
IDIQ Option 4
| FACILITY INVESTMENT SERVICES FOR MAINTENANCE AND REPAIR OF ABOVE GROUND STORAGE TANKS (AST) AND |
| UNDERGROUND STORAGE TANKS (UST) AT NAVAL STATION NEWPORT AND NAVAL UNDERSEA WARFARE CENTER, |
| NEWPORT RHODE ISLAND AND OTHER AREAS OF RESPONSIBILITY |
CLIN 0010 - THIRD OPTION PERIOD - SCHEDULE OF INDEFINITE QUANTITY WORK
Item No. Supplies/Services Unit of issue Unit Price Total Amount Price Amount
| E700 | Pump sumps ans spill containers of hazardous materials | 2 | GL | $ - 0 | $ - 0 |
| as indicated in Annex 3.1.2 | 5500 | | | |
| E701 | Removal/Installation of Veeder Root Systems | 30 | EA | $ - 0 | $ - 0 |
| E702 | Tank Vents | 102 | | | |
| E702A | 2" | 117 | EA | $ - 0 | $ - 0 |
| E702B | 3" | 146 | EA | $ - 0 | $ - 0 |
| E702C | 4" | 208 | EA | $ - 0 | $ - 0 |
| E702D | Provide labor to perform all Unit Priced Labor Work subject to the Service Contract Act per the scope and delivery schedule specified in the order. Must be negotiated by KO using ETO process. | 1 | EA | $ - 0 | $ - 0 |
| Provide all materials and equipment (not listed on IDIQ ELINS) on to perform Unit Priced Labor work per the scope and delivery schedule specified in the order. Use ELIN A702. These material costs must be negotiated by KO using ETO process. | | | | |
Total IQ Line Items E700 through E704 $ - 0
FOURTH OPTION YEAR TOTAL
SUMMARY
| BASE OPTION | BASE IDIQ |
| $ - 0 | $0.00 |
| FIRST OPTION | FIRST OPTION IDIQ |
| $ - 0 | $0.00 |
| SECOND OPTION | SECOND OPTION IDIQ |
| $ - 0 | $0.00 |
| THIRD OPTION | THIRD OPTION IDIQ |
| $ - 0 | $0.00 |
| FOURTH OPTION | FOURTH OPTION IDIQ |
| $ - 0 | $0.00 |
| TOTAL SUM RECURRING WORK FIVE YEARS | TOTAL SUM NON-RECURRING WORK FIVE YEARS |
| $ - 0 | $ - 0 |