1UTILITY CONNECTIONS
1UTILITY CONNECTIONS
C3
F-401
FP UTILITY CONNECTION
WITH 5" STORZ FDC
C1
F-401
FP UTILITY CONNECTION
WITH 5" STORZ FDC
TEE, 8" x 4" x 4"
90° ELBOW, 4" x 4"
90° ELBOW, 4" x 4"
4" CONNECTION
TEE, 4" x 4" x 2"
TEE, 4" x 2.5" x 2.5"
TOPSIDE HOSE STATION #1
TOPSIDE HOSE STATION #2
TEE, 2" x 2" x 2"
INTERNAL HOSE REEL #1
INTERNAL HOSE REEL #2
HYDRAULIC NODE POINTS
WORK NOTES:
1. UTILITY CONNECTIONS, SEE PART PLAN CIVIL DRAWINGS.
2. FOR FIRE PROTECTION PIPING AND APPURTANCES, SEE CIVIL
DRAWINGS.
3. HYDRAULIC NODE POINTS ON TEMPORARY PIPING AND
FITTINGS NOT SHOWN ON DRAWINGS.
4. HYDRAULIC NODE POINTS IN UTILITY STATION. SEE FIRE
PROTECTION DRAWING F-401.
DESIGN CRITERIA:
HYDRAULIC CALCULATION NO. 1
SUPPLY: PERMANENT SHIPYARD HIGH-PRESSURE WATER SYSTEM
TOPSIDE HOSE DEMAND: 95 GPM AT 60 PSI (X2)
INTERNAL HOSE DEMAND: 18 GPM AT 36 PSI (X2)
TOTAL DEMAND: 226 GPM AT 115 PSI
(MINIMUM PRESSURES AT THE NOZZLE)
HYDRAULIC CALCULATION NO. 2
SUPPLY: F&ES PUMPING APPARATUS CONNECTED AT THE FDC (MAXIMUM
APPARATUS SUPPLY PRESSURE OF 175 PSI)
TOTAL DEMAND: 500 GPM AT 150 PSI
(MINIMUM RESIDUAL TOPSIDE HOSE STATION MANIFOLD PRESSURE)
HYDRAULIC DESIGN DATA:
VIEW NUMBER
SHEET WHERE
VIEW IS SHOWN
A1
A-001
HYDRAULIC NODE REFERENCE POINT
NEW WORK KEY NOTE NUMBER
LEGEND:
0 20'10'
1" = 10'
F I R
E
P
R O
T E
C T
I O
N
P
L A
N
P
I E
R
E
N D
F-101
12805730
AS NOTED
KJC DSM KAR
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
R E
P
LA
C E
S S
N B
E R
TH
IN
G P
IE
R
N A
V A
L
S
U B
M A
R I N
E
B
A S
E
N
E W
L O
N D
O N
G R
O T
O N
C
T
1565917
N40085-20-R-0037
D
P A
R T
M E
N T
F
T
H
A V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
F I
M
E
Y
S h a r e d L e g a c y U
S W
K F
D P r o j J e n s e n H u g h e s K u r t
R u c h a l a L C
D
P i e r
N e w o n d o n D r a w i n g s F d g
Y O
U
M
E
F
P
O
T T
E D
M o n d a y
J a n u a r y p m
S E
R d m a r t e l
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
C I
C
O R
E
H
A M
P T
R
A
D S
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
I R
G I N
I
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
LBT/APG
EJA
01/06/20
BRIAN A. KUERBITZ
PLAN
NORTH
SCALE: 1" = 10'
FIRE PROTECTION PLAN - PIER 32 END
M A
T C
H
L I N
E
S
A
W I N
G
F
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1UTILITY CONNECTIONS
1 UTILITY CONNECTIONS
C3
F-401
FP UTILITY CONNECTION
WITH 5" STORZ FDC
C1
F-401
FP UTILITY CONNECTION
WITH 5" STORZ FDC
1. UTILITY CONNECTIONS, SEE PART PLAN CIVIL DRAWINGS.
2. FOR FIRE PROTECTION PIPING AND APPURTANCES, SEE CIVIL
DRAWINGS.
3. PROVIDE 8" GATE VALVE.
VIEW NUMBER
SHEET WHERE
VIEW IS SHOWN
A1
A-001
GATE VALVE
NEW WORK KEY NOTE NUMBER
LEGEND:
0 20'10'
1" = 10'
F I R
E
P
R O
T E
C T
I O
N
P
L A
N
P
I E
R
M
I D
D L
E
F-102
12805731
AS NOTED
KJC DSM KAR
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
R E
P
LA
C E
S S
N B
E R
TH
IN
G P
IE
R
N A
V A
L
S
U B
M A
R I N
E
B
A S
E
N
N D
O N
G R
O T
O N
C
T
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
F I
M
E
Y
S h a r e d L e g a c y U
S W
K F
D P r o j J e n s e n H u g h e s K u r t
R u c h a l a L C
D
P i e r
N n d o n D r a w i n g s F d
Y O
M
E
F
O
T T
E D
M o n d a y
J a n u a r y
E
R d m a r t e l
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
C I
C
O R
E
H
A M
P T
A
D S
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
I R
G I N
CHIEF ENG/ARCH
FIRE PROTECTION
LBT/APG
EJA
01/06/20
BRIAN A. KUERBITZ
PLAN
NORTH
SCALE: 1" = 10'
FIRE PROTECTION PLAN - PIER 32 MIDDLE
M A
T C
H
L I N
E
S
A
W I N
G
F
M A
T C
H
L I N
E
S
A
W I N
G
F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
W
W
P
I
V
W
2 FIRE HYDRANT
5" STORZ FDC
AT BFP ENCLOSURE
C2
F-501
8" RPBFP
2FIRE HYDRANT
HYDRAULIC NODE POINTS
1. FOR FIRE PROTECTION PIPING AND APPURTANCES, SEE CIVIL
DRAWINGS.
2. FIRE HYDRANT, SEE CIVIL DRAWINGS
3. 5" STORZ FDC, SEE FIRE PROTECTION DRAWING F-501 AND CIVIL
DRAWINGS. FDC SHALL BE LOCATED NOT LESS THAN 18 INCHES OR
MORE THAN 48 INCHES ABOVE THE LEVEL OF ADJOINING GRADE
(MEASURED FROM GRADE TO THE CENTER OF THE INLETS).
4. CONNECT TO EXISTING 12" HPW.
5. FIRE PROTECTION SUPPLY FROM 12" HPW.
6. PROVIDE UL/FM APPROVED IN-LINE EXPANSION JOINT FOR FIRE
PROTECTION.
7. PROVIDE 3/4" AUTOMATIC DRAIN VALVE LOCATED AT LOW POINT.
8. HYDRAULIC NODE POINTS FROM WATER SUPPLY.
WATER SUPPLY (LOCATED AT HP-2-18)
90° ELBOW, 6" x 6"
TEE, 12" x 12" x 6"
TEE, 12" X 12" X 12"
TEE, 12" X 12" X 8"
90° ELBOW, 8" X8"
90° ELBOW, 8" X 8"
LEGEND:
HIGH PRESSURE WATER (HPW) - DESIGNED BY OTHERS
HIGH PRESSURE FIRE PROTECTION (FP) WATER
FIRE HYDRANT
FIRE DEPARTMENT CONNECTION (FDC)
GATE VALVE
POST INDICATOR VALVE (PIV)
REDUCED PRESSURE BACKFLOW PREVENTER (BFP)
HYDRAULIC NODE REFERENCE POINT
NEW WORK KEY NOTE NUMBER
VIEW NUMBER
SHEET WHERE
VIEW IS SHOWN
A1
A-001
PIV
FP
HPW
0 20'10'
1" = 10'
F I R
E
P
R O
T E
C T
I O
N
P
L A
N
P
I E
R
L
A N
D
S
I D
E
N
O R
T H
F-103
12805732
AS NOTED
KJC DSM KAR
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
R E
P
LA
C E
S S
N B
E R
TH
IN
G P
IE
R
N A
V A
L
S
U B
M A
R I N
E
B
A S
E
N
N D
O N
G R
O T
O N
C
T
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
F I
M
E
Y
S h a r e d L e g a c y U
S W
K F
D P r o j J e n s e n H u g h e s K u r t
R u c h a l a L C
D
P i e r
N n d o n D r a w i n g s F d
Y O
M
E
F
O
T T
E D
M o n d a y
J a n u a r y
E
R d m a r t e l
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
C I
C
O R
E
H
A M
P T
A
D S
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
I R
G I N
CHIEF ENG/ARCH
FIRE PROTECTION
LBT/APG
EJA
01/06/20
BRIAN A. KUERBITZ
PLAN
NORTH
SCALE: 1" = 10'
FIRE PROTECTION PLAN - PIER 32 LAND SIDE NORTH
M A
T C
H
L I N
E
S
A
W I N
G
F
AutoCAD SHX Text
BUILDING 295
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
SLAB=5.95
AutoCAD SHX Text
PED DOOR SILL=5.95
AutoCAD SHX Text
OHD DOOR SILL=10.45
AutoCAD SHX Text
FENDER
AutoCAD SHX Text
SILL=5.63
AutoCAD SHX Text
4DP
AutoCAD SHX Text
5DP
AutoCAD SHX Text
WV
AutoCAD SHX Text
5DP
AutoCAD SHX Text
3DP
AutoCAD SHX Text
12"WATER
AutoCAD SHX Text
THAMES RIVER
AutoCAD SHX Text
FLOOD
AutoCAD SHX Text
EBB
AutoCAD SHX Text
AMBERJACK ROAD
AutoCAD SHX Text
12"WATER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE INSULATED & HEATED ENCLOSURE
LOCK BOX FOR FP (SEE NOTE 7)
LATERAL UTILITY TRENCH
4" FP
4" 8010 FIREMAIN
CONNECTION W/
CAP & CHAIN
INDICATING BUTTERFLY
CONTROL VALVE
4" CHECK VALVE
W/ BALL DRIP
STANDARD FITTINGS
WITH 4" x 2 1/2" x 2 1/2"
WALL HYDRANT WITH
2 1/2" GATE VALVES
4" PLUG
TYPE VALVE
5" STORZ FDC W/ CAP AND
CHAIN
4" CHECK VALVE
W/ BALL DRIP
4" PLUG TYPE VALVE
IN VERTICAL POSITION
PROVIDE INSULATED & HEATED ENCLOSURE
LOCK BOX FOR FP (SEE NOTE 7)
LATERAL
UTILITY
TRENCH
4" FP
4" 8010 FIREMAIN
CONNECTION W/
CAP & CHAIN
INDICATING BUTTERFLY
CONTROL VALVE
4" CHECK VALVE
W/ BALL DRIP
STANDARD FITTINGS
WITH 4" x 2 1/2" x 2 1/2"
WALL HYDRANT WITH
2 1/2" GATE VALVES
4" PLUG
TYPE VALVE
5" STORZ FDC W/
CAP AND CHAIN
4" CHECK VALVE
W/ BALL DRIP
4" PLUG TYPE VALVE
IN VERTICAL POSITION
TOP OF RAISED
UTILITY TRENCH
PIER DECK
TOP OF RAISED
UTILITY TRENCH
PIER DECK
LATERAL
UTILITY
TRENCH
4" FP
A P
P R
O X
A B
O V
E
P
I E
R
D
E C
K
4" 8010 FIREMAIN
CONNECTION W/
CAP & CHAIN
STANDARD FITTINGS
WITH 4" x 2 1/2" x 2 1/2"
WALL HYDRANT WITH
2 1/2" GATE VALVES
4" CHECK
VALVE WITH
BALL DRIP
4" PLUG
TYPE VALVE
5" STORZ FDC W/
CAP AND CHAIN
4" PLUG
TYPE VALVE
SECURE ELBOW BASE TO
CHECKERED PLATE TRENCH
COVER AND COORDINATE PIPE
SUPPORT LOCATIONS (SEE NOTE 7)
SUPPORT 4" FP
TO TRENCH WALL
PROVIDE INSULATED & HEATED ENCLOSURE
LOCK BOX FOR FP (SEE NOTE 7)
A P
P R
O X
A B
O V
E
P
I E
R
D
E C
K
INDICATING BUTTERFLY
CONTROL VALVE IN
HORIZONTAL POSITION
TOP OF RAISED
UTILITY TRENCH
PIER DECK
TOP OF RAISED
UTILITY TRENCH
PIER DECK
LATERAL
UTILITY
TRENCH
4" FP
A P
P R
O X
A B
O V
E
P
I E
R
D
E C
K
4" 8010 FIREMAIN
CONNECTION W/
CAP & CHAIN
STANDARD FITTINGS
WITH 4" x 2 1/2" x 2 1/2"
WALL HYDRANT WITH
2 1/2" GATE VALVES
4" CHECK
VALVE WITH
BALL DRIP
4" PLUG
TYPE VALVE
5" STORZ FDC W/ CAP AND
CHAIN
4" PLUG
TYPE VALVE
SECURE ELBOW BASE TO
CHECKERED PLATE TRENCH COVER
AND COORDINATE PIPE SUPPORT
LOCATIONS (SEE NOTE 7)
SUPPORT 4" FP
TO TRENCH WALL
PROVIDE INSULATED & HEATED ENCLOSURE
LOCK BOX FOR FP (SEE NOTE 7)
A P
P R
O X
A B
O V
E
P
I E
R
D
E C
K
INDICATING BUTTERFLY
CONTROL VALVE IN
HORIZONTAL POSITION
HYDRAULIC NODE POINTS
NOTES:
1. A UL3112 LISTED CHECK VALVE SHALL BE INSTALLED IN LINE TO THE
FDC.
2. AN ISOLATION VALVE SHALL BE PROVIDED BETWEEN THE FDC AND THE
CHECK VALVE.
3. APPROVED AUTOMATIC DRIP VALVES ARRANGED TO ALLOW DRAINAGE
WITHOUT CAUSING WATER DAMAGE, SHALL BE INSATLLED AT THE LOW
POINT IN EACH ISOLATABLE SECTION IN THE PIPING BETWEEN THE FDC
AND CHECK VALVE.
4. ALL FDC VALVES SHALL BE LOCATED NOT LESS THAN 18 INCHES OR
MORE THAN 48 INCHES ABOVE THE LEVEL OF ADJOINING GRADE
(MEASURED FROM GRADE TO THE CENTER OF THE INLETS).
5. PROVIDE SIGNAGE POSTED STATING "FDC" AND "DO NOT OBSTRUCT". A
SIGN SHALL ALSO STATE "DO NOT EXCEED 175 PSI SUPPLY PRESSURE".
SIGNAGE LETTERS SHALL BE AT LEAST 1" IN HEIGHT.
6. ALL PIPING, FITTINGS AND VALVES ABOVE THE PIER DECK SHALL BE
STAINLESS STEEL.
7. PROVIDE INSULATED & HEATED ENCLOSURE LOCK BOX FOR FP
(HUBBELL HOT BOX HB4000 FLIP TOP OR EQUIVALENT). FLOOR WILL BE
CHECKERED GALVANIZED PLATE TRENCH COVER. SEE SHEET S-514.
90° ELBOW, 4" x 4"
90° ELBOW, 4" x 4"
4" CONNECTION
VIEW NUMBER
SHEET WHERE
VIEW IS SHOWN
A1
A-001
HYDRAULIC NODE REFERENCE POINT
LEGEND:
0 1' 2' 3'
3/4" = 1'
F I R
E
P
R O
T E
C T
I O
N
C
O N
N E
C T
I O
N
P
A R
T
P
L A
C
T I O
N S
F-401
12805733
AS NOTED
KJC DSM KAR
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
R E
P
LA
C E
S S
N B
E R
TH
IN
G P
IE
R
N A
V A
L
S
U B
M A
R I N
E
B
A S
E
N
N D
O N
G R
O T
O N
C
T
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
F I
M
E
Y
S h a r e d L e g a c y U
S W
K F
D P r o j J e n s e n H u g h e s K u r t
R u c h a l a L C
D
P i e r
N n d o n D r a w i n g s F d
Y O
M
E
F
O
T T
E D
M o n d a y
J a n u a r y
E
R d m a r t e l
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
C I
C
O R
E
H
A M
P T
A
D S
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
I R
G I N
CHIEF ENG/ARCH
FIRE PROTECTION
LBT/APG
EJA
01/06/20
BRIAN A. KUERBITZ
SCALE: 3/4" = 1'-0"
SECTION
A1
F-401
SCALE: 3/4" = 1'-0"
PART PLAN - TYPICAL FIRE PROTECTION UTILITY CONNECTION (NORTH SIDE)
C1
F-101, F-102
SCALE: 3/4" = 1'-0"
PART PLAN - TYPICAL FIRE PROTECTION UTILITY CONNECTION (SOUTH SIDE)
C3
F-101, F-102
SCALE: 3/4" = 1'-0"
SECTION
A3
F-401
A1
F-401
A3
F-401
8" OS&Y GATE VALVE
8" RPBFP
8" OS&Y GATE VALVE
PROVIDE INSULATED AND
HEATED ENCLOSURE
(SEE NOTE 8)
14'-0"
HEATER
HEATER
6" x 5" STORZ
CONNECTION W/ CAP
AND CHAIN
6" DIP
6" CHECK VALVE
W/ BALL DRIP
6" BUTTERFLY VALVE
C1
SU401
BACKFLOW PREVENTER
STRUCTURE
HYDRAULIC NODE POINTS
NOTES:
1. A UL3112 LISTED CHECK VALVE SHALL BE INSTALLED IN LINE TO THE
FDC.
2. ISOLATION VALVES SHALL BE PROVIDED BETWEEN THE PERMANENT
SHIPYARD WATER SOURCE AND THE BACKFLOW PREVENTER, AND
BETWEEN THE FDC AND THE CHECK VALVE.
3. APPROVED AUTOMATIC DRIP VALVES ARRANGED TO ALLOW DRAINAGE
WITHOUT CAUSING WATER DAMAGE, SHALL BE INSATLLED AT THE LOW
POINT IN EACH ISOLATABLE SECTION IN THE PIPING BETWEEN THE FDC
AND CHECK VALVE.
4. ALL FDC VALVES SHALL BE LOCATED NOT LESS THAN 18 INCHES OR
MORE THAN 48 INCHES ABOVE THE LEVEL OF ADJOINING GRADE
(MEASURED FROM GRADE TO THE CENTER OF THE INLETS).
5. PROVIDE SIGNAGE POSTED STATING "FDC" AND "DO NOT OBSTRUCT". A
SIGN SHALL ALSO STATE "DO NOT EXCEED 175 PSI SUPPLY PRESSURE".
SIGNAGE LETTERS SHALL BE AT LEAST 1" IN HEIGHT.
6. SEE CIVIL DRAWINGS FOR PIPE SUPPORTS, INSULATION AND
ADDITIONAL DIMENSIONS.
7. SEE CIVIL DRAWINGS FOR BACKFLOW PREVENTER STRUCTURE.
8. PROVIDE INSULATED & HEATED ENCLOSURE LOCK BOX FOR FP
(HUBBELL HOT BOX HB4000 FLIP TOP OR EQUIVALENT).
90° ELBOW, 8" x 8"
90° ELBOW, 8" x 8"
VIEW NUMBER
SHEET WHERE
VIEW IS SHOWN
A1
A-001
HYDRAULIC NODE REFERENCE POINT
LEGEND:
14'-0"
8" OS&Y GATE VALVE
8" RPBFP
8" OS&Y GATE VALVE
HEATER
BACKFLOW PREVENTER
STRUCTURE
C1
SU401
9'-10"
14'-0"
8" DIP
INSULATION
PROVIDE INSULATED AND
HEATED ENCLOSURE
(SEE NOTE 8)
HEATER
6" x 5" STORZ
CONNECTION W/ CAP
AND CHAIN
6" CHECK VALVE
W/ BALL DRIP
6" BUTTERFLY VALVE
2' 4'0 1'
1/2" = 1'
F I R
E
P
R O
T E
C T
I O
N
B
A C
K F
L O
W
P
R E
V E
N T
T
A I L
F-501
12805734
AS NOTED
KJC DSM KAR
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
R E
P
LA
C E
S S
N B
E R
TH
IN
G P
IE
R
N A
V A
L
S
U B
M A
R I N
E
B
A S
E
N
N D
O N
G R
O T
O N
C
T
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
F I
M
E
Y
S h a r e d L e g a c y U
S W
K F
D P r o j J e n s e n H u g h e s K u r t
R u c h a l a L C
D
P i e r
N n d o n D r a w i n g s F d
Y O
M
E
F
O
T T
E D
M o n d a y
J a n u a r y
E
R d m a r t e l
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
C I
C
O R
E
H
A M
P T
A
D S
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
I R
G I N
CHIEF ENG/ARCH
FIRE PROTECTION
LBT/APG
EJA
01/06/20
BRIAN A. KUERBITZ
SCALE: 1/2" = 1'-0"
SECTION
A2
F-501
SCALE: 1/2" = 1'-0"
REDUCED PRESSURE BACKFLOW PREVENTER PLAN
C2
F-501
A2
F-501
KING FISHER
RADIO BOX
HEAT TRACE
CONTROL PANEL
BACKFLOW PREVENTER
ENCLOSURE
1. PROVIDE KING FISHER RADIO BOX. ALL ELECTRONICS MUST
BE HOUSED IN A NEMA 3R ENCLOSURE. PROVIDE
CONNECTION TO TEMPORARY CASCON SYSTEM INSTALLED
BY THE GOVERNMENT. SEE FIRE ALARM DRAWING FA501.
2. HEAT TRACE CONTROL PANEL, SEE ELECTRICAL DRAWINGS.
LEGEND:
LOW TEMPERATURE SENSOR
CONTROL PANEL
NEW WORK KEY NOTE NUMBER
1. SEE FIRE ALARM DRAWING FA501 FOR CONCEPTUAL FIRE ALARM RISER
DIAGRAM.
NOTES:
0 20'10'
1" = 10'
F I R
E
A
L A
M
A
N
P
I E
R
L
A N
D
S
I D
E
N
O R
T H
FA101
12805735
AS NOTED
KJC DSM KAR
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
R E
P
LA
C E
S S
N B
E R
TH
IN
G P
IE
R
N A
V A
L
S
U B
M A
R I N
E
B
A S
E
N
N D
O N
G R
O T
O N
C
T
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
F I L
E
N
A M
E
Y
S h a r e d L e g a c y U
S W
K F
D P r o j J e n s e n H u g h e s K u r t
R u c h a l a
L C
D i e r
N n d o n D r a w i n g s F
A d
Y
O U
T
N
A M
E
F
A
O
T T
E D
M o n d a y
J a n u a r y p m
U
S E
R d m a r t e l
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
C I
C
O R
E
H
A M
P T
A
D S
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
I R
G I N
CHIEF ENG/ARCH
FIRE PROTECTION
LBT/APG
EJA
01/06/20
BRIAN A. KUERBITZ
PLAN
NORTH
SCALE: 1" = 10'
FIRE ALARM PLAN - PIER 32 LAND SIDE NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. PROVIDE KING FISHER RADIO BOX. ALL ELECTRONICS MUST
BE HOUSED IN A NEMA 3R ENCLOSURE. PROVIDE
CONNECTION TO TEMPORARY CASCON SYSTEM INSTALLED
BY THE GOVERNMENT.
2. OUTSIDE OF DESIGN SCOPE. TO BE PROVIDED BY SUBBASE
TEMPORARY SERVICES.
3. HEAT TRACE MONITORING - PER NFPA 14
4. INSIDE OF HEATED ENCLOSURE FOR FP UTILITY
CONNECTION. SEE FIRE PROTECTION DRAWINGS.
LEGEND:
ADDRESSABLE HEAT DETECTOR
ADDRESSABLE SMOKE DETECTOR
LOW TEMPERATURE SENSOR
MONITOR MODULE
SPEAKER STROBE
ANTENNA
HOMERUN TO PANELBOARD
NEW WORK KEY NOTE NUMBER
S
MM
VIEW NUMBER
SHEET WHERE
VIEW IS SHOWN
A1
A-001
S
F I R
E
A
L A
M
T
A I L
S
FA501
12805736
AS NOTED
KJC DSM KAR
A
B
C
D
2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
R E
P
LA
C E
S S
N B
E R
TH
IN
G P
IE
R
N A
V A
L
S
U B
M A
R I N
E
B
A S
E
N
N D
O N
G R
O T
O N
C
T
P A
R T
M E
T
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
C
O M
M A
N D
F I L
E
N
A M
E
Y
S h a r e d L e g a c y U
S W
K F
D P r o j J e n s e n H u g h e s K u r t
R u c h a l a
L C
D i e r
N n d o n D r a w i n g s F
A d
Y
O U
T
N
A M
E
F
A
O
T T
E D
M o n d a y
J a n u a r y p m
U
S E
R d m a r t e l
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
C I
C
O R
E
H
A M
P T
A
D S
N A
V A
L
S
T A
T I O
N
N
O R
F O
L K
V
I R
G I N
CHIEF ENG/ARCH
FIRE PROTECTION
LBT/APG
EJA
01/06/20
BRIAN A. KUERBITZ
HEAT TRACE
CONTROL PANEL
KING FISHER
RADIO BOX
INSIDE OF
SUBMARINE HULL
CASCON
STATION
KING FISHER RADIO BOX
AT PIER 32 END
SUBSTATION P32N
SWITCHGEAR HOUSE
BACKFLOW PREVENTER
ENCLOSURE
SCALE: NTS
CONCEPTUAL FIRE ALARM RISER DIAGRAM
C3
FIRE ALARM
CONTROL PANEL
SCALE: NTS
KING FISHER RADIO BOX DETAIL
A2
P32NP-8
SEE ELECTRICAL
DRAWINGS
RETURN TO KING
FISHER RADIO BOX
RETURN TO KING
FISHER RADIO BOX
16.25"
ZONE 1
ZONE 3
ZONE 4
A2
FA501
LEXAN VIEWING WINDOW
NEMA 3R ENCLOSURE
ZONE 2
RETURN TO KING
FISHER RADIO BOX
ZONE 5
FP UTILITY
CONNECTION HEATED
ENCLOSURE
(TYPICAL OF FOUR)
SCALE: NTS
DEVICES AT FP UTILITY CONNECTION HEATED ENCLOSURES
A4
FA501
A4
FA501
4 4
| STRUCTURAL UTILITIES | |
| SU401 | BACKFLOW PREVENTER STRUCTURE PLAN AND SECTIONS |
SU402 ELEVATED SWITCHGEAR PLATFORM PART PLAN AND SECTIONS
SU501 STRUCTURAL PIPE SUPPORT DETAILS
SU502 CRANE WEIGHT TEST PAD AND LIGHT POLE DETAILS
SU503 ELEVATED PLATFORM DETAILS
| FIRE PROTECTION | |
| F-101 | FIRE PROTECTION PLAN - PIER 32 END |
F-102 FIRE PROTECTION PLAN - PIER 32 MIDDLE
F-103 FIRE PROTECTION PLAN - PIER 32 LAND SIDE NORTH
F-401 FIRE PROTECTION CONNECTION PLANS AND SECTIONS
F-501 FIRE PROTECTION REDUCED PRESSURE BACK FLOW PREVENTER DETAIL
FA101 FIRE ALARM PLAN – PIER 32 LAND SIDE NORTH
FA501 FIRE ALARM DETAILS
| MECHANICAL | |
| M-001 | LEGEND, ABBREVIATIONS AND GENERAL NOTES |
M-101 COMPRESSED AIR PLAN - PIER 32 LAND SIDE NORTH
M-501 COMPRESSED AIR DETAILS
M-502 PIPE SUPPORT DETAILS - SHEET 1 OF 2
M-503 PIPE SUPPORT DETAILS - SHEET 2 OF 2
M-601 COMPRESSED AIR SCHEDULES
M-701 HVAC SEQUENCE OF OPERATIONS
2020-01-30T15:43:24-0500
2020-01-30T15:42:44-0500
2020-01-30T15:43:44-0500
2020-01-30T15:43:01-0500
2020-01-30T15:43:44-0500
2020-01-30T15:43:01-0500
2020-01-30T15:43:43-0500
2020-01-30T15:43:00-0500
2020-01-30T15:43:45-0500
2020-01-30T15:43:00-0500
2020-01-30T15:44:29-0500
2020-01-30T15:44:57-0500
2020-01-30T15:44:56-0500
2020-01-30T15:44:55-0500
2020-01-30T15:44:55-0500
2020-01-30T15:44:54-0500
2020-01-30T15:44:54-0500
| 2020-02-12T16:46:54-0500 | |
| Chris Jobe |
| 2020-02-12T16:47:12-0500 | |
| Chris Jobe |
| 2020-02-12T16:47:15-0500 | |
| Chris Jobe |
| 2020-02-12T16:47:17-0500 | |
| Chris Jobe |
| 2020-02-12T16:47:19-0500 | |
| Chris Jobe |
2020-02-13T10:52:22-0500
2020-02-13T10:52:40-0500
2020-02-13T10:52:43-0500
2020-02-13T10:52:46-0500
2020-02-13T10:52:51-0500
2020-02-13T10:52:54-0500
2020-02-13T10:52:57-0500
2020-02-13T10:53:00-0500
2020-02-13T10:53:06-0500
2020-02-13T10:53:10-0500
2020-02-13T10:53:14-0500
2020-02-13T10:53:17-0500
2020-02-13T10:53:20-0500
2020-02-13T10:53:24-0500
2020-02-13T10:53:27-0500
2020-02-13T10:53:30-0500
2020-02-13T10:53:32-0500
2020-02-13T10:53:36-0500
2020-02-13T10:53:39-0500
| 2020-02-14T08:32:05-0500 | |
| Norfolk, VA | |
| Amy Garcia | |
| I am signing to certify the authenticity of this document. |
| 2020-02-14T08:32:18-0500 | |
| Norfolk, VA | |
| Amy Garcia | |
| I am signing to certify the authenticity of this document. |
| 2020-02-14T08:32:22-0500 | |
| Norfolk, VA | |
| Amy Garcia | |
| I am signing to certify the authenticity of this document. |
| 2020-02-14T08:32:25-0500 | |
| Norfolk, VA | |
| Amy Garcia | |
| I am signing to certify the authenticity of this document. |
| 2020-02-14T08:32:28-0500 | |
| Norfolk, VA | |
| Amy Garcia | |
| I am signing to certify the authenticity of this document. |
| 2020-02-14T08:32:32-0500 | |
| Norfolk, VA | |
| Amy Garcia | |
| I am signing to certify the authenticity of this document. |
| 2020-02-14T08:32:38-0500 | |
| Norfolk, VA | |
| Amy Garcia | |
| I am signing to certify the authenticity of this document. |
| 2020-02-15T19:59:49-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:00:20-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:00:21-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:00:36-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:00:46-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:00:58-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:01:10-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:01:20-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:01:31-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:01:43-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:01:54-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:02:07-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:02:19-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:02:31-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:02:44-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:02:54-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:03:04-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:03:15-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:03:27-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:17-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:38-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:39-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:40-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:42-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:43-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:44-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:46-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:47-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:49-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:50-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:51-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:53-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:54-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:56-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:57-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:04:59-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:05:00-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2020-02-15T20:05:02-0500 | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
File details come from the government source that posted it. Updated .