N0017821R4401 QA-6th Round.pdf
PDF 123 KB Posted
- Attached to
- RF & Circuit Design Assembly & Fabrication Support Federal contract opportunity
- Solicitation number
- N00178-21-R-4401
About this file
This document contains questions and answers regarding cable termination specifications for a Navy contract opportunity. The opportunity, solicitation number N00178-21-R-4401, is for RF and circuit design, assembly, and fabrication support services to be provided to the Department of the Navy Naval Sea Systems Command. Per the questions and answers, splices for shielded cables must be placed within drawing specifications and any unused shielding should be covered with heat shrink as acceptable per the customer's preferences.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N0017821R4401 QA-5th Round.pdf | ||
| N0017821R4401 QA-4th Round.pdf | ||
| N0017821R4401 QA-3rd Round.pdf | ||
| N0017821R4401 0003.pdf | ||
| N0017821R4401 QA-2nd Round.pdf | ||
| N0017821R4401 Questions and Answers.pdf | ||
| J.3 DO 0002 - SOW_rev.pdf | ||
| N0017821R4401 (Conform Copy 03FEB2021).pdf | ||
| N0017821R4401 0002.pdf | ||
| N0017821R4401 0001.pdf | ||
| N0017821R4401.pdf | ||
| J.2 DO 0001 - SOW.pdf | ||
| J.3 DO 0002 - SOW.pdf | ||
| Exhibit A - CDRLs A001-A004.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. AS50881, 3.19.4.d specifies: "Splices shall not be used within 12 inches of a termination device..." The drawing (‐001 thru ‐005) shows the splice within the three‐inch label placement dimension. See ‐002 excerpt below. We need to know where the customer prefers the placement of the splice in relation to the connector.
Answer: Place the shield termination as per the drawing.
2. What does the customer wish to do with the shield that is not used on the ‐006 cable? We recommend covering it with heat shrink.
Answer: Covering with heat shrink is acceptable.