This document provides details regarding solicitation number N00024-22-R-4412 issued by the Naval Sea Systems Command for the USS NITZE (DDG 94) FY23 DEPOT MODERNIZATION PERIOD availability. The solicitation seeks a contractor to complete maintenance, modernization, and repair work during a 21 month period from July 2023 through April 2025. Interested parties must register in the System for Award Management and monitor the SAM.gov website for solicitation documents and amendments. The solicitation involves restricted technical attachments related to execution milestones, pricing, and compartment closeout that require a written request to obtain. The agency anticipates making a single award for the work in or around January 2023.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PPI FORM
| USS NITZE (DDG 94) DMP N00024-22-R-4412 | RFP | |||||
| Attachment S-3 Pre-Proposal Information (PPI) Form | Attachment J-1 | |||||
| NAVSEA POC: | CDR Jonathan Pagnucco; jonathan.pagnucco@navy.mil | Attachment J-2 | ||||
| Nelimar Munoz; nelimar.munoz-martin@navy.mil | Attachment J-3 | |||||
| Attachment J-4 | ||||||
| Question # | Question Area | Work Iem (if applicable) | Section/Para | Contractor Question | Government Response | Attachment J-5 |
| 44 | Attachment J-1 | 438-90-001 | 2.8 | The Pc V0075 and V0090 describe a 900 PSI Globe Socket Weld valve, but it doesn't give a size anywhere in the description. Please provide the size of these two valves. | Items V0075 and V0090 are 2" NPS . | |
| 45 | Attachment J-1 | 438-90-001 | 2.14 | There is a discrepancy in Ref. 2.14, Sheet 51 of RLAR 71604/DDG94/1203078. It describes a continuous hinge “blank butt steel plain”, but then goes on to describe a "hinge with holes." Please clarify what is required. | Item 536 is a Piano hinge. The holes are referring to the barrel of the hinge for the pin. | |
| 46 | Attachment J-1 | 438-90-002 & 980-90-025 | 3.21 and 3.19 respectively | Para 3.21 covers new decking in the chartroom (para 1.2.1.2) and 980-90-025 covers the same space, Chartroom (para 1.2.6). We recommend Para 3.19 and 3.19.1 be deleted from 980-90-025 | Government concurs that there is a duplicate requirement. Para 1.2.1.2 is deleted from para 3.21. ERRATA 3 is forthcoming. | |
| 47 | Attachment J-1 | 463-90-001 | 2.2 | Pc No 180 describes 18 each Screws, Cap, .190-32 UNRF-3A. But it doesn't provide the length. Please provide this information | Item 180 is 1" LG. | |
| 48 | Attachment J-1 | 480-11-001 | 3.1 | No references are invoked/ provided that identify the cables/ equipment listed in 1.3 that are to be removed in para 3.1, and new equipment install |