Mt Home Chapel B13 - Bid Documents_Part2.pdf
PDF 19 MB Posted
- Attached to
- Z2DZ--36C249-21-AP-3989 - Project 621-20-101 Correct FCA Deficiencies w Historical Chapel Building 13
- Solicitation number
- 36C24921B0017
About this file
This notice solicits bids for correcting deficiencies at the Historical Chapel Building 13 at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. Work includes selective demolition, abatement of environmental hazards including mold, lead-based paint, and asbestos-containing materials, as well as modifications, restorations, and new construction of interior and exterior features such as the roof, walls, stairs, ramps, handrails, sidewalks, landscaping, lighting, and signage. Mechanical, electrical, plumbing, data, communications, and fire suppression systems will also be upgraded. The solicitation number is 36C24921B0017 and will be posted on October 15, 2021, with bids due by November 16, 2021. This is a 100% set-aside for verified Service-Disabled Veteran-Owned Small Businesses. The estimated value is between $2,000,000 to $5,000,000. The NAICS code is 236220 and size standard is $39.5 million. The Department of Veterans Affairs Veterans Health Administration VISN 9 is the contracting agency.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
0' - 0"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
WATER TABLE
2' - 9 31/32"
ROOF BOTTOM
24' - 1 5/32"
3 3 3 3 3
B/O TOWER ROOF
52' - 9 19/32"
8 8
AE302
AE302
AE302
AE302
AE301
AE301
AE301
AE301
AAAAA
AE131
AS432
TYP. TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
C
F
13 13
H
G 4
AS432
AS432
AE402
AE402
16 17
TYP.
TYP.
TYP.
TYP.
G E N E R A L N O T E S :
A. CLEAN EXTERIOR BRICK, STONE BANDS, AND STONE SILLS - SEE SPECIFICATIONS.
B. NEW BRICK AND MORTAR SHALL MATCH EXISTING BRICK AND MORTAR IN COLOR, PROFILE,
AND CONSISTENCY.
C. ALL EXTERIOR PAINTED WOOD SHALL BE STRIPPED OF LOOSE PAINT AND MADE SMOOTH.
THERE MAY BE WOOD MEMBERS THAT HAVE BEEN SEVERELY DAMAGED BY WEATHERING.
CONTRACTOR SHALL ASSESS DAMAGE TO WOOD AND NOTIFY C.O.R. PRIOR TO THE START
OF REFINISHING AND REPAINTING SO THE UNIT CAN BE PROPERLY REPAIRED OR
REPLACED.
D. ANY EQUIPMENT ITEM, ARCHITECTURAL ITEM, OR ELECTRICAL LIGHT FIXTURE, THAT NEEDS
TO BE REMOVED FROM THE BUILDING TO BE REPAIRED, REFURBISHED, OR REFINISHED
SHALL BE PHOTOGRAPHED AND CATALOGED. THE CATALOG RECORD OF THESE ITEMS
SHALL BE DELIVERED TO THE VA AT THE END OF EACH WORK WEEK OR AS DIRECTED BY
THE VA C.O.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:0
P
M
AE201
ELEVATIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/4" = 1'-0"
SOUTH - ELEVATION
D R A W I N G N O T E S :
1 CLEAN AND REPAIR EXTERIOR LIGHT FIXTURE, PROVIDE NEW LIGHT BULBS AS NEEDED.
2 REGRADE TO SLOPE AWAY FROM EXTERIOR WALLS - SEED AND STRAW DISTURBED
SOIL.
3 INSTALL NEW WINDOW PER SCHEDULE.
4 REMOVE LOOSE PAINT AND MAKE SMOOTH - REPAINT WOOD FRAMING.
5 REPLACE DAMAGED OR MISSING SLATE ROOF TILES - SIXTY (60) TOTAL - SEE ROOF
PLAN FOR APPROXIMATE LOCATIONS.
6 TUCK-POINT BRICK FROM 2FT ABOVE GRADE AND DOWN TO FOOTING. MATCH EXISTING
MORTAR CONSISTENCY AND PROFILE. STAIN MORTAR TO MATCH EXISTING ADJACENT
COLOR.
7 REMOVE DIRT AND DEBRIS FROM ALL EXTERIOR BRICK WALLS FROM GRADE TO 3FT
ABOVE GRADE.
8 REMOVE JOINT SEALANT AT STONE COPING - REPLACE WITH HEAVY DUTY SEALANT
AND BACKER ROD.
9 RESEAL AND REFASTEN ROOF RIDGELINE.
10 REMOVE EXISTING METAL COPING - REPLACE WITH NEW METAL COPING OVER NEW 2X
PT BLOCKING. REFER TO DETAIL
11 INSTALL CAST ALUMINUM CROSS MOUNTED TO EXISTING ROOF. REFER TO AE402 FOR
DETAILS.
12 EXISTING COPPER GUTTERS TO REMAIN.
13 EXISTING SLATE TILE ROOF TO REMAIN - REMOVE ALGAE AND VEGETATIVE GROWTH
FROM FULL EXTENT OF SLATE ROOF.
14 ALUMINUM GUARDRAIL.
15 NEW BRICK WALL AT STAIR AND / OR RAMP - SEE SECTIONS AND DETAILS ON SHEET
AS431
16 NEW ALUMINUM HANDRAIL AT 3'-0" AFF AND ALUMINUM GUARDRAIL AT 3'-6" AFF -
EXTEND HANDRAIL 12" PAST TOP AND BOTTOM RISER - SEE RAMP AND STAIR SECTIONS
AND DETAILS.
17 CAST STONE CAP.
18 CONCRETE STAIR.
19 BRICK WRAPPED CMU COLUMN WITH 4" STONE CAP
20 NEW ALUMINUM HANDRAIL AT 36" ABOVE STAIR NOSING - EXTEND 12" PAST TOP AND
BOTTOM RISER - RETURN HANDRAIL TO THE GROUND.
21 NEW CONCRETE RAMP - SEE SECTIONS AND DETAILS ON SHEET AS431
22 LOUVER TO BE ADDED TO WINDOW - SEE MECHANICAL DRAWINGS.
No. Revisions: Date:
BASEMENT
-9' - 6 11/16"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
WATER TABLE
2' - 9 31/32"
B/O TOWER ROOF
52' - 9 19/32"
AE301
AE301
AE301
AE301
AE302
AE302
AE302
AE302
AA A
A A
AE131
AE131
AS432
AS501
C
E E
4 4 4 4
AS432
AS501
007A
TYP.
TYP.
TYP.
TYP.
14 15
G E N E R A L N O T E S :
A. CLEAN EXTERIOR BRICK, STONE BANDS, AND STONE SILLS - SEE SPECIFICATIONS.
B. NEW BRICK AND MORTAR SHALL MATCH EXISTING BRICK AND MORTAR IN COLOR, PROFILE,
AND CONSISTENCY.
C. ALL EXTERIOR PAINTED WOOD SHALL BE STRIPPED OF LOOSE PAINT AND MADE SMOOTH.
THERE MAY BE WOOD MEMBERS THAT HAVE BEEN SEVERELY DAMAGED BY WEATHERING.
CONTRACTOR SHALL ASSESS DAMAGE TO WOOD AND NOTIFY C.O.R. PRIOR TO THE START
OF REFINISHING AND REPAINTING SO THE UNIT CAN BE PROPERLY REPAIRED OR
REPLACED.
D. ANY EQUIPMENT ITEM, ARCHITECTURAL ITEM, OR ELECTRICAL LIGHT FIXTURE, THAT NEEDS
TO BE REMOVED FROM THE BUILDING TO BE REPAIRED, REFURBISHED, OR REFINISHED
SHALL BE PHOTOGRAPHED AND CATALOGED. THE CATALOG RECORD OF THESE ITEMS
SHALL BE DELIVERED TO THE VA AT THE END OF EACH WORK WEEK OR AS DIRECTED BY
THE VA C.O.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:2
P
M
AE202
ELEVATIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/4" = 1'-0"
EAST - ELEVATION
D R A W I N G N O T E S :
1 TUCK-POINT BRICK FROM 2FT ABOVE GRADE AND DOWN TO FOOTING. MATCH EXISTING
MORTAR CONSISTENCY AND PROFILE. STAIN MORTAR TO MATCH EXISTING ADJACENT
COLOR.
2 REMOVE DIRT AND DEBRIS FROM ALL EXTERIOR BRICK WALLS FROM GRADE TO 3FT ABOVE
GRADE.
3 REPLACE DAMAGED OR MISSING SLATE ROOF TILES - SIXTY (60) TOTAL - SEE ROOF PLAN
FOR APPROXIMATE LOCATIONS.
4 INSTALL NEW WINDOW PER SCHEDULE.
5 REMOVE JOINT SEALANT AT STONE COPING - REPLACE WITH HEAVY DUTY SEALANT AND
BACKER ROD.
6 RESEAL AND REFASTEN ROOF RIDGELINE.
7 REMOVE LOOSE PAINT AND MAKE SMOOTH - REPAINT WOOD FRAMING.
8 EXISTING COPPER GUTTERS TO REMAIN.
9 EXISTING SLATE TILE ROOF TO REMAIN - REMOVE ALGAE AND VEGETATIVE GROWTH FROM
FULL EXTENT OF SLATE ROOF.
10 NEW ALUMINUM HANDRAIL AT 3'-0" AFF AND ALUMINUM GUARDRAIL AT 3'-6" AFF - EXTEND HANDRAIL 12" PAST TOP AND BOTTOM RISER - SEE RAMP AND STAIR SECTIONS AND DETAILS.
11 BRICK WRAPPED CMU COLUMN WITH 4" STONE CAP
12 NEW ALUMINUM HANDRAIL AT 36" ABOVE STAIR NOSING - EXTEND 12" PAST TOP AND
BOTTOM RISER - RETURN HANDRAIL TO THE GROUND.
13 CONCRETE STAIR - PROVIDE RISERS AT MAXIMUM 7" AND TREADS AT MINIMUM 11".
14 NEW BRICK WALL AT STAIR AND / OR RAMP - SEE SECTIONS AND DETAILS ON SHEET AS431
15 NEW CONCRETE RAMP - SEE SECTIONS AND DETAILS ON SHEET AS431
BALCONY
10' - 1 5/8"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
WATER TABLE
2' - 9 31/32"
5 5 5 5 5
AE302
AE302
AE302
AE302
AE301
AE301
AE301
AE301
AA A A A
C
D D D D
11 11
TYP.
TYP.
TYP.
TYP.
TYP.
TYP. TYP.
TYP.
TYP.
TYP.
B
AS432
AE402
G E N E R A L N O T E S :
A. CLEAN EXTERIOR BRICK, STONE BANDS, AND STONE SILLS - SEE SPECIFICATIONS.
B. NEW BRICK AND MORTAR SHALL MATCH EXISTING BRICK AND MORTAR IN COLOR, PROFILE,
AND CONSISTENCY.
C. ALL EXTERIOR PAINTED WOOD SHALL BE STRIPPED OF LOOSE PAINT AND MADE SMOOTH.
THERE MAY BE WOOD MEMBERS THAT HAVE BEEN SEVERELY DAMAGED BY WEATHERING.
CONTRACTOR SHALL ASSESS DAMAGE TO WOOD AND NOTIFY C.O.R. PRIOR TO THE START
OF REFINISHING AND REPAINTING SO THE UNIT CAN BE PROPERLY REPAIRED OR
REPLACED.
D. ANY EQUIPMENT ITEM, ARCHITECTURAL ITEM, OR ELECTRICAL LIGHT FIXTURE, THAT NEEDS
TO BE REMOVED FROM THE BUILDING TO BE REPAIRED, REFURBISHED, OR REFINISHED
SHALL BE PHOTOGRAPHED AND CATALOGED. THE CATALOG RECORD OF THESE ITEMS
SHALL BE DELIVERED TO THE VA AT THE END OF EACH WORK WEEK OR AS DIRECTED BY
THE VA C.O.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:4
P
M
AE203
ELEVATIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/4" = 1'-0"
NORTH - ELEVATION
D R A W I N G N O T E S :
1 INFILL EXISTING OPENING IN BRICK WALL WITH SALVAGED MATCHING BRICK - USE
BRICK FROM EXPOSED WALLS IN CRAWL SPACE - REPLACE CRAWL SPACE BRICK WITH
SIMILAR BRICK FROM SALVAGE YARD.
2 TUCK-POINT BRICK FROM 2FT ABOVE GRADE AND DOWN TO FOOTING. MATCH EXISTING
MORTAR CONSISTENCY AND PROFILE. STAIN MORTAR TO MATCH EXISTING ADJACENT
COLOR.
3 REMOVE DIRT AND DEBRIS FROM ALL EXTERIOR BRICK WALLS FROM GRADE TO 3FT
ABOVE GRADE.
4 REPLACE DAMAGED OR MISSING SLATE ROOF TILES - SIXTY (60) TOTAL - SEE ROOF
PLAN FOR APPROXIMATE LOCATIONS.
5 INSTALL NEW WINDOW PER SCHEDULE.
6 REMOVE LOOSE PAINT AND MAKE SMOOTH - REPAINT WOOD FRAMING.
7 REMOVE JOINT SEALANT AT STONE COPING - REPLACE WITH HEAVY DUTY SEALANT
AND BACKER ROD.
8 RESEAL AND REFASTEN ROOF RIDGELINE.
9 REATTACH EXISTING DOWNSPOUT TO COPPER GUTTER.
10 INSTALL CAST ALUMINUM CROSS MOUNTED TO EXISTING ROOF. REFER TO AE402 FOR
DETAILS.
11 EXISTING SLATE TILE ROOF TO REMAIN - REMOVE ALGAE AND VEGETATIVE GROWTH
FROM FULL EXTENT OF SLATE ROOF.
12 LOUVER TO BE ADDED TO WINDOW - SEE MECHANICAL DRAWINGS.
BALCONY
10' - 1 5/8"
BASEMENT
-9' - 6 11/16"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
WATER TABLE
2' - 9 31/32"
3 3
AE301
AE301
AE301
AE301
AE302
AE302
AE302
AE302
A AAAA
AE131
AE131
C DD D D
6 6 6 6 6
6 6 6
TYP.
TYP.
TYP.
TYP.
TYP. TYP.
TYP. TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
B
AS501
G E N E R A L N O T E S :
A. CLEAN EXTERIOR BRICK, STONE BANDS, AND STONE SILLS - SEE SPECIFICATIONS.
B. NEW BRICK AND MORTAR SHALL MATCH EXISTING BRICK AND MORTAR IN COLOR, PROFILE,
AND CONSISTENCY.
C. ALL EXTERIOR PAINTED WOOD SHALL BE STRIPPED OF LOOSE PAINT AND MADE SMOOTH.
THERE MAY BE WOOD MEMBERS THAT HAVE BEEN SEVERELY DAMAGED BY WEATHERING.
CONTRACTOR SHALL ASSESS DAMAGE TO WOOD AND NOTIFY C.O.R. PRIOR TO THE START
OF REFINISHING AND REPAINTING SO THE UNIT CAN BE PROPERLY REPAIRED OR
REPLACED.
D. ANY EQUIPMENT ITEM, ARCHITECTURAL ITEM, OR ELECTRICAL LIGHT FIXTURE, THAT NEEDS
TO BE REMOVED FROM THE BUILDING TO BE REPAIRED, REFURBISHED, OR REFINISHED
SHALL BE PHOTOGRAPHED AND CATALOGED. THE CATALOG RECORD OF THESE ITEMS
SHALL BE DELIVERED TO THE VA AT THE END OF EACH WORK WEEK OR AS DIRECTED BY
THE VA C.O.R.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:0
P
M
AE204
ELEVATIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/4" = 1'-0"
WEST- ELEVATION
D R A W I N G N O T E S :
1 TUCK-POINT BRICK FROM 2FT ABOVE GRADE AND DOWN TO FOOTING. MATCH EXISTING
MORTAR CONSISTENCY AND PROFILE. STAIN MORTAR TO MATCH EXISTING ADJACENT
COLOR.
2 REMOVE DIRT AND DEBRIS FROM ALL EXTERIOR BRICK WALLS FROM GRADE TO 3FT
ABOVE GRADE.
3 REPLACE DAMAGED OR MISSING SLATE ROOF TILES - SIXTY (60) TOTAL - SEE ROOF
PLAN FOR APPROXIMATE LOCATIONS.
4 REMOVE JOINT SEALANT AT STONE COPING - REPLACE WITH HEAVY DUTY SEALANT
AND BACKER ROD.
5 RESEAL AND REFASTEN ROOF RIDGELINE.
6 INSTALL NEW WINDOW PER SCHEDULE.
7 EXISTING SLATE TILE ROOF TO REMAIN - REMOVE ALGAE AND VEGETATIVE GROWTH
FROM FULL EXTENT OF SLATE ROOF.
8 INSTALL CAST ALUMINUM CROSS MOUNTED TO EXISTING ROOF. REFER TO AE402 FOR
DETAILS.
9 REMOVE LOOSE PAINT AND MAKE SMOOTH - REPAINT WOOD FRAMING.
10 NEW 24" X 28" LOUVER - REFER TO MECHANICAL DRAWINGS.
BALCONY
10' - 1 5/8"
BASEMENT
-9' - 6 11/16"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
AE302
AE302
AE301
AE301
AE301
AE301
11 11 1
2 2 2 2
AE131
P-2
ST-1
P-2
ST-1
P-2 P-2
ST-1
P-2
5 WEST CHAPEL
STAGE
WEST CRAWL SPACE
MECHANICAL 2
MECHANICAL 1
TOWER STAIR
ENTRANCE
TOWER LANDING
BELL LANDING
WEST BALCONY
AE311
AE311
AS501
FIRST FLOOR
0' - 0"
BALCONY
10' - 1 5/8"
BASEMENT
-9' - 6 11/16"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
AE302
AE302
AE302
AE302
AE301
AE301
AE301
AE301
AS431
2 2 2 2
11 1 1 1
WEST CHAPEL
AE131
P-2
ST-1
P-2
P-2
ST-1
P-2
P-2
ST-1
AE601
STAGE
WEST BALCONY
ENTRANCE
MECHANICAL 1
MECHANICAL 2
TOWER STAIR
TOWER LANDING
BELL LANDING
P-2
FIRST FLOOR
0' - 0"
BASEMENT
-9' - 6 11/16"
AE301
AE301
AE301
AE301
P-2
ST-1
P-2
P-2
ST-1
WEST CHAPEL
WEST CRAWL SPACE
FIRST FLOOR
0' - 0"
BALCONY
10' - 1 5/8"
BASEMENT
-9' - 6 11/16"
AE301
AE301
AE301
AE301
AE311
AE131
P-2
ST-1
P-2
P-2
ST-1
AS501
WEST CHAPEL
WEST CRAWL SPACE
AE502
AE502
G E N E R A L N O T E S :
A. ANY EQUIPMENT ITEM, ARCHITECTURAL ITEM OR ELECTRICAL LIGHT FIXTURE, THAT NEEDS TO BE REMOVED FROM THE BUILDING TO BE REPAIRED, REFURBISHED, OR REFINISHED SHALL BE PHOTOGRAPHED AND CATALOGED. THE CATALOG RECORD OF THESE ITEMS SHALL BE DELIVERED TO THE VA AT THE END OF EACH WORK WEEK OR AS
DIRECTED BY THE VA C.O.R.
B. INDICATIONS FOR REFINISHING OF WOODWORK OR FLOORING SHALL INCLUDE STRIPPING OF OLD FINISH OR PAINT DOWN TO BARE WOOD. SAND SMOOTH ALL SURFACES, SEAL WOOD, RESTAIN AND COAT WITH SPECIFIED VARNISH.
C. ALL EXTERIOR WOOD IS SCHEDULED TO RECEIVE NEW NEW PAINT - SEE FINISH SCHEULE AND LEGEND
D. ALL HARDWOOD FLOORS SHALL RECEIVE NEW STAIN - SEE FINISH SCHEDULE AND LEGEND.
E. SEAL AROUND ALL EXTERIOR PIPE OPENINGS IN THE EXTERIOR WALLS WITH EXTERIOR SEALANT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:2
P
M
AE301
WEST CHAPEL - SECTIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/8" = 1'-0"
NORTH SECTION - LONG
1/8" = 1'-0"
SOUTH SECTION - LONG
1/8" = 1'-0"
EAST SECTION - SHORT
1/8" = 1'-0"
WEST SECTION - SHORT
D R A W I N G N O T E S :
1 INSTALL NEW WINDOW PER SCHEDULE.
2 EXISTING WALL SCONCE TO REMAIN.
3 CLEAN WOOD BEAMS AND TRUSSES. CLEAN EXPOSED FINISHED CEILING/DECKING.
4 NEW WALL SCONCE TO REPLICATE EXISTING WALL SCONCE.
5 COORDINATE WOODWORK WITH DEMOLITION PHASE. STAIN TO MATCH ADJACENT WOOD TRIM.
6 SEE AE402 AND ORGAN RESTORATION FOR WORK IN THIS AREA.
7 REMOVE FLAKING AND CRACKING PAINT, MAKE SMOOTH, AND REPAINT WOOD CORNICES - SEE LEAD-BASED PAINT
ABATEMENT SPECIFICATION.
8 REMOVE FLAKING AND CRACKING PAINT, MAKE SMOOTH, AND REPAINT WOOD BRACKETS - SEE LEAD-BASED PAINT
ABATEMENT SPECIFICATION.
9 REMOVE FLAKING AND CRACKING PAINT, MAKE SMOOTH, AND REPAINT ROSE WINDOW TRIM.
10 INSTALL CAST ALUMINUM CROSS MOUNTED TO EXISTING ROOF. REFER TO AE402 FOR DETAILS.
11 EXISTING WOOD FRAMING TO REMAIN.
12 REFURBISHED STAIN-GLASS WINDOW - SEE SECTIONS, ELEVATIONS, AND SHEET AE602.
13 EXISTING SLATE SHINGLES - SEE ROOF PLAN FOR EXTENT OF NEW ROOFING WORK.
14 REFURBISH EXISTING BELL AND ASSOCIATED CONSTRUCTION. REFER TO SHEET AE402 FOR MORE DETAILS.
15 ALUMINUM 75 DEGREE SHIPS LADDER AT 19'-8" HIGH WITH ROOF ACCESS HATCH.
16 NEW 30" X 30" OPENING - PROVIDE STEEL PLATE LINTEL AT TOP OF OPENING - 4" BEARING AT EACH SIDE OF LINTEL
17 NEW STRUCTURAL FRAMING. REFER TO STRUCTURAL DRAWINGS FOR DETAILS.
18 6 X 8 WOOD BEAM MOUNTED TO EXISTING TRUSSES WITH ORNAMENTAL JOIST HANGER.
19 14'-0" DIA. CEILING FAN - SEE MECHANICAL DRAWINGS.
20 WATER RESISTANT POURED RUBBER FLOORING TO MATCH EXISTING.
21 STAIN PULPIT AND ALTAR RAILING - SEE FINISH SCHEDULE.
22 LOUVER TO BE ADDED TO WINDOW - SEE MECHANICAL DRAWINGS.
23 VERTICAL STAINLESS STEEL LADDER AT 9'-0" HIGH.
24 GRATED METAL ACCESS HATCH.
BALCONY
10' - 1 5/8"
BASEMENT
-9' - 6 11/16"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
AE131
AE301
AE301
AE301
AE301
AE302
AE302
AE302
AE302
P-2
ST-1
P-2
ST-1
P-2
P-2CTW-1
ST-1
ST-1
CTW-1
P-2
2 2 2 2
BELL LANDING
TOWER LANDING
TOWER STAIR
TOWER STAIR
MECHANICAL 2
ENTRANCE
NORTH BALCONY
NORTH CHAPEL
STAGE
NORTH CRAWL SPACE
IT
AE441
AE311
FIRST FLOOR
0' - 0"
BALCONY
10' - 1 5/8"
BASEMENT
-9' - 6 11/16"
TOWER LANDING
19' - 5 3/8"
BELL LANDING
39' - 1 23/32"
AE131
AE301
AE301
AE301
AE301
AE302
AE302
AE302
AE302
AE131
P-2
ST-1
P-2
ST-1
P-2
P-2
1 1
2 2 2 2
/2
/8
NORTH CHAPEL
STAGE
BELL LANDING
TOWER LANDING
TOWER STAIR
MECHANICAL 2
NORTH CRAWL SPACE
IT
ENTRANCE
NORTH BALCONY
AE441
FIRST FLOOR
0' - 0"
BASEMENT
-9' - 6 11/16"
AE302
AE302
AE302
AE302
AE441
P-2
ST-1
P-2 P-2
NORTH CHAPEL
NORTH CRAWL SPACE
10 9
FIRST FLOOR
0' - 0"
BASEMENT
-9' - 6 11/16"
AE302
AE302
AE302
AE302
P-2P-2
P-2
ST-1ST-1
AE311
NORTH CRAWL SPACE
NORTH CHAPEL
AS501
AE502
G E N E R A L N O T E S :
A. ANY EQUIPMENT ITEM, ARCHITECTURAL ITEM OR ELECTRICAL LIGHT FIXTURE, THAT NEEDS TO BE REMOVED FROM THE BUILDING TO BE REPAIRED, REFURBISHED, OR REFINISHED SHALL BE PHOTOGRAPHED AND CATALOGED. THE CATALOG RECORD OF THESE ITEMS SHALL BE DELIVERED TO THE VA AT THE END OF EACH WORK WEEK OR AS
DIRECTED BY THE VA C.O.R.
B. INDICATIONS FOR REFINISHING OF WOODWORK OR FLOORING SHALL INCLUDE STRIPPING OF OLD FINISH OR PAINT DOWN TO BARE WOOD. SAND SMOOTH ALL SURFACES, SEAL WOOD, RESTAIN AND COAT WITH SPECIFIED VARNISH.
C. ALL EXTERIOR WOOD IS SCHEDULED TO RECEIVE NEW NEW PAINT - SEE FINISH SCHEULE AND LEGEND
D. ALL HARDWOOD FLOORS SHALL RECEIVE NEW STAIN - SEE FINISH SCHEDULE AND LEGEND.
E. SEAL AROUND ALL EXTERIOR PIPE OPENINGS IN THE EXTERIOR WALLS WITH EXTERIOR SEALANT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:4
P
M
AE302
NORTH CHAPEL - SECTIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/8" = 1'-0"
EAST SECTION - LONG
1/8" = 1'-0"
WEST SECTION - LONG
1/8" = 1'-0"
SOUTH SECTION - SHORT
1/8" = 1'-0"
NORTH SECTION - SHORT
D R A W I N G N O T E S :
1 INSTALL NEW WINDOW PER SCHEDULE.
2 EXISTING WALL SCONCE TO REMAIN.
3 CLEAN WOOD BEAMS AND TRUSSES. CLEAN EXPOSED FINISHED CEILING/DECKING.
4 SEE AE402 AND ORGAN RESTORATION FOR WORK IN THIS AREA.
5 EXISTING WOOD FRAMING TO REMAIN.
6 EXISTING SLATE SHINGLES - SEE ROOF PLAN FOR EXTENT OF NEW ROOFING WORK.
7 INSTALL CAST ALUMINUM CROSS MOUNTED TO EXISTING ROOF. REFER TO AE402 FOR DETAILS.
8 ALUMINUM 75 DEGREE SHIPS LADDER AT 19'-8" HIGH WITH ROOF ACCESS HATCH.
9 6 X 8 WOOD BEAM MOUNTED TO EXISTING TRUSSES WITH ORNAMENTAL JOIST HANGER.
10 14'-0" DIA. CEILING FAN - SEE MECHANICAL DRAWINGS.
11 NEW WOOD SUBFLOOR AND WOOD FINISH FLOOR TO MATCH EXISTING FLOORING IN SPECIES AND SIZE.
12 WATER RESISTANT POURED RUBBER FLOORING TO MATCH EXISTING.
13 STAIN RAILINGS, BALLUSTERS, AND POSTS ST-1 TO MATCH EXISTING INTERIOR TRIM. REFER TO 11/AE502 FOR MORE
INFORMATION.
14 COORDINATE WOODWORK WITH DEMOLITION PHASE. STAIN TO MATCH ADJACENT WOOD TRIM.
15 BALCONY WOODWORK RAILINGS, BALUSTERS AND POSTS TO REMAIN - STRIP PAINT AND PREPARE SURFACES TO BE
SMOOTH TO RECEIVE NEW FINISHES.
16 24" X 28" OPENING FOR NEW LOUVER - PROVIDE4 STEEL PLATE LINTEL AT TOP OF OPENING - 6" BEARING AT EACH
SIDE OF LINTEL - SUPPORT STRUCTURE ABOVE FOR BRICK REMOVAL.
EXISTING MULTI-WYTHE BRICK WALL
TUCK-POINT BRICK MORTAR JOINTS - SEE ELEVATIONS
FLUID-APPLIED DAMPPROOFING MEMBRANE
GRAVEL FILL FOR DRAINAGE
FILTER FABRIC
FILL
4" PERFORATED DRAIN TILE IN FILTER FABRIC
EXISTING STONE WATERTABLE
EXISTING STONE SILL
NEW ALUMINUM-FRAMED WINDOW
EXISTING PAINTED WOOD
STRUCTURE - REMOVE LOOSE PAINT
AND MAKE SMOOTH - REPAINT
EXISTING SLATE TILE ROOFING - SEE
ROOFING PLAN AND DETAILS
EXISTING HISTORIC WOOD BASE -
REMOVE, STRIP PAINT, STAIN AND SEAL
WOOD, AND REINSTALL ON NEW WALL
5/8" TYPE X GYPSUM BOARD
2 1/2" COLD-FORMED STEEL FRAMING
CLIPPED TO EXISTING BRICK WALL AT
4'-0" O.C. VERTICALLY - SIZE AND
SPACING SHALL MEET MANUFACTURER'S
DESIGN SPANS - HOLD 1/2" OFF EXISTING
BRICK WALL - NOTIFY ARCHITECT AND
C.O.R. IF ADDITIONAL DISTANCE IS
REQUIRED FOR IRREGULAR BRICK
TOLERANCES.
REFINISH EXISTING WOOD FLOOR -
WHERE EXISTING FLOORING IS
PLYWOOD OR OSB, PROVIDE NEW WOOD
PLANK FLOORING TO MATCH EXISTING
ADJACENT - TOOTH-IN TO BLEND WITH
ORIGINAL FLOORING. PROVIDE SPACERS
BENEATH WOOD PLANK FLOORING TO
MAKE FLOOR LEVEL.
EXISTING WOOD BRACKETS AND
TRUSSES TO REMAIN
5/8" TYPE X GYPSUM BOARD
12 MIL VAPOR BARRIER OVER
EXISTING SOIL IN SUBBASEMENT
EXISTING FOOTING - UNKNOWN DEPTH,
SIZE, AND MATERIAL
DRAINAGE BOARD
EXISTING WOOD JOISTS
H O
L D
PATCH EXISTING
PLASTER AND PAINT
DECORATIVE GRAVEL FILL - SEE CIVIL DRAWINGS
6" WIDE CONCRETE MOW STRIP PAVER
3' - 0" WASHED GRAVEL AROUND DRAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:0
P
M
AE311
WALL SECTIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/2" = 1'-0"
CHAPEL WALL SECTION
HOLD
5' - 0"
/4
/2
1' - 5 1/2" 1' - 3"
/4
/2
6 1/2"
/4
1' - 2 3/4"
106B
106A
AE401
AE401
ACCESSIBLE RESTROOM
RESTROOM
T-5
T-1
T-2
T-2
T-5
T-6
T-4
T-4
T-3 T-3
T-6
4' - 6 1/4" +/-
T-7
AE401
C
4' - 0 1/4" +/-
6"
5' - 6"
T-8
T-8
T-9
3 3
T-9
T-7 D
D
C
6' - 6 3/4" +/-
2' - 1 1/4"
/2
112A
112B
AE401
4 6
AE401
ACCESSIBLE RESTROOM
RESTROOM
T-2
T-1
T-2T-3
T-6
T-5
T-5T-4
T-4
4 4
AE401
D
/2
11' - 3 1/4"
/4
4' - 3 3/4"
T-8
T-8
2A
2A
T-9
T-9
T-3
DD
C
AE502
/2
T-1 T-2
T-3
P-2
CTB-1
T-9
DD
P-2
CTB-1
T-1
T-4T-5
T-7
T-6
P-2
CTB-1
P-2
T-1
T-2 T-6 T-5
T-4 P-2
CTB-1
T-3
T-9
C
" T-7
T-4 T-5
P-2
CTB-1
P-2
T-6
P-2
T-7
T-4
CTB-1
T-2
T-3
P-2
CTB-1
T-9
T-6
P-2
T-2
T-3
T-4 T-6
P-2
CTB-1
T-7
T-5
1 5
T-9
T-3 T-2 T-1 T-7
P-2
CTB-1
C
T-6
T-4
T-5
T-7
P-2
CTB-1
P-2
T-1
P-2
CTB-1
T-2
T-1
T-3
P-2
CTB-1 3
DD
T-9
T-2T-6T-5 T-3
P-2
CTB-1
T-3 T-2
T-9
P-2
CTB-1
T-7
T-4
P-2
CTB-1
T-7T-4 T-5
P-2
CTB-1
P-2
T-6
3 5/8" COLD FORMED
STEEL FRAMING
5/8" GYPSUM
WALLBOARD
5 1/2" COLD FORMED
STEEL FRAMING
WOOD SILL PAINTED TO
MATCH EXISTING
ADJACENT CONSTRUCTION.
BRAKE METAL
V.I.F.
1' - 5 1/4"
5/8" GYPSUM
WALLBOARD
3 1/2" BATT INSULATION
5 1/2" COLD FORMED
STEEL FRAMING
BRAKE
METAL
5/8" GYPSUM WALL
BOARD ON 5 1/2" COLD
FORMED STEEL FRAMING
5/8" GYPSUM WALL BOARD
ON 5 1/2" COLD FORMED
STEEL FRAMING
5/8" GYPSUM WALL BOARD
ON 3 5/8" COLD FORMED
STEEL FRAMING
WOOD SILL PAINTED TO
MATCH EXISTING
ADJACENT
CONSTRUCTION
V .I .F
/4
G E N E R A L N O T E S :
A. INDICATIONS FOR REFINISHING OF WOODWORK OR FLOORING SHALL INCLUDE STRIPPING OF OLD FINISH OR PAINT DOWN TO BARE WOOD. SAND SMOOTH ALL SURFACES, SEAL WOOD, RESTAIN AND COAT WITH SPECIFIED VARNISH.
B. ALL HARDWOOD FLOORS SHALL RECEIVE NEW STAIN - SEE FINISH SCHEDULE AND LEGEND.
C. REFER TO SHEET G001 FOR TYPICAL RESTROOM FIXTURES, HEIGHTS, AND FLOOR CLEARANCES.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:1
P
M
AE401
ENLARGED RESTROOM PLANS,
ELEVATIONS, AND DETAILS
Owner
07/30/2021 GA TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/2" = 1'-0" A
ENLARGED RESTROOM - NORTH TRANSEPT
1/2" = 1'-0"
B
ENLARGED RESTROOM - WEST TRANSEPT
D R A W I N G N O T E S :
1 LAVATORY GUARD TO MEET ACCESSIBILITY CLEARANCES PER DIAGRAM ON G001.
2 EXISTING WINDOW TRIM REINSTALLED ON NEW FURRED OUT WALL.
3 FLOOR MOUNTED ACCESSIBLE WATER CLOSET. REFER TO PLUMBING DRAWINGS.
4 WALL MOUNTED ACCESSIBLE LAVATORY. REFER TO PLUMBING DRAWINGS.
5 SEE TYPICAL WET WALL ELEVATION ON SHEET AF801.
1/4" = 1'-0"
ACCESSIBLE RESTROOM 114 - NORTH
1/4" = 1'-0"
ACCESSIBLE RESTROOM 114 - EAST
1/4" = 1'-0"
ACCESSIBLE RESTROOM 114 - SOUTH
1/4" = 1'-0"
ACCESSIBLE RESTROOM 114 - WEST
1/4" = 1'-0"
RESTROOM 113 - NORTH
1/4" = 1'-0"
RESTROOM 113 - EAST
1/4" = 1'-0"
RESTROOM 113 - SOUTH
1/4" = 1'-0"
RESTROOM 113 - WEST
1/4" = 1'-0"
ACCESSIBLE RESTROOM 107 - NORTH
1/4" = 1'-0"
ACCESSIBLE RESTROOM 107 - EAST
1/4" = 1'-0"
ACCESSIBLE RESTROOM 107 - SOUTH
1/4" = 1'-0"
ACCESSIBLE RESTROOM 107 - WEST
1/4" = 1'-0"
RESTROOM 108 - NORTH
1/4" = 1'-0"
RESTROOM 108 - EAST
1/4" = 1'-0"
RESTROOM 108 - SOUTH
1/4" = 1'-0"
RESTROOM 108 - WEST
TOILET ACCESSORY SCHEDULE
MARK DESCRIPTION FURNISHED INSTALLED
T-1 36" GRAB BAR CONTRACTOR CONTRACTOR
T-2 42" GRAB BAR CONTRACTOR CONTRACTOR
T-3 TOILET PAPER DISPENSER CONTRACTOR CONTRACTOR
T-4 PAPER TOWEL DISPENSER CONTRACTOR CONTRACTOR
T-5 SOAP DISPENSER CONTRACTOR CONTRACTOR
T-6 18" x 36" MIRROR CONTRACTOR CONTRACTOR
T-7 WASTE RECEPTABLE CONTRACTOR CONTRACTOR
T-8 COAT HOOK CONTRACTOR CONTRACTOR
T-9 18" GRAB BAR CONTRACTOR CONTRACTOR
1" = 1'-0" C
WINDOW DETAIL - ENLARGED RESTROOM - NORTH TRANSEPT
1" = 1'-0" D
WINDOW DETAIL - ENLARGED RESTROOM - WEST TRANSEPT
EXISTING
WEST ORGAN
RELOCATED ORGAN
PIPES, TYP.
STAGE
EXISTING
NORTH
ORGAN
NORTH BALCONY
EXISTING ORGAN
PIPES ABOVE ENTRY
EXISTING ORGAN PIPES
TO BE REINSTALLED AT
EXISTING LOCATION
G E N E R A L O R G A N O T E S :
A. REMOVE THE EXISTING CASE AND ORGAN, INCLUDING CAREFULLY PACKING THE PIPEWORK SO AS NOTE TO DAMAGE
EXISTING PIPES. INVENTORY PIPES AS REMOVED. ONCE TRANSPORTED OFF SITE FACILITY, COMPLETE A LAYOUT OF ALL
PIPES TO DETERMINE STATUS AND NECESSARY REPAIRS.
B. INSPECT, CATALOG, AND WASH EACH SALVAGEABLE PIPE. MISSING OR DAMAGED PIPES WILL BE NOTED AND REPAIRED, OR REPLACED AS NECESSARY.
C. CATALOG AND DIMENSION EXISTING COMPONENTS TO BE REUSED.
D. CONSTRUCT A NEW CONSOLE SHELL, TO MATCH PREVIOUS. BUILD NEW ALL-ELECTRIC CHESTS TO REPLACE EXISTING
ELECTRO-PNEUMATIC CHESTS.
E. COMPLETE CONSTRUCTION OF CONSOLE CASE AND ASSOCIATED PARTS. REFER TO EVALUATION REPORT FOR MORE
INFORMATION
F. PARTS OF EXISTING CASEWORK DEEMED REUSABLE WILL BE PROFESSIONALLY TANK-STRIPPED, RE-DIMENSIONED, AND ALTERED TO FIT NEW PLAN. NEW CASEWORK OF WOOD IN KIND SHALL NEED TO BE CONSTRUCTED AS NEEDED TO FINISH
THE EXPOSED-TO-VIEW CABINETWORK
G. PIPES SHALL BE FITTED TO THE NEW WINDCHESTS, WITH APPROPRIATE ADDITIONAL RACKS AND BRACING FOR TALLER PIPES. WINDCHESTS SHALL BE CONSTRUCTED OF HEAVY POPLAR LUMBER AND MULTI-PLY VOIDLESS PLYWOOD. ALL NON- VISIBLE WOODWORK SHALL BE FINISHED WITH TWO COATS OF LACQUER SANDING-SEALER, SANDED BETWEEN COATS.
ELECTRO-MAGNETIC VALVES SHALL BE INSTALLED UNDER PIPE HOLES ONCE ALL PIPES HAVE BEEN FITTED TO NEW
CHEST SHELLS.
H. WINDCHESTS SHALL BE FITTED WITH NEW WIRING HARNESS AFTER FINISHING, WITH MAGNETS WIRED IN A LOOM, USING
HIGH-QUALITY COLORED TELEPHONE CABLE
I. CONSTRUCT A NEW FLOOR FRAME OUTLINING THE SPACE THAT SHALL BE OCCUPIED IN THE CHAPEL, FINISH NEW FRAME.
REFER TO ORGAN EVALUATION REPORT FOR MORE INFORMATION.
J. EACH ORGAN SHALL BE BUILT FOLLOWING THE ABOVE SPECIFICATIONS AND THE ORGAN EVALUATION REPORT .
DEDUCT ALTERNATE: ORGAN IS REMOVED AND STORED ON VA CAMPUS. VA SHALL ISSUE A SEPARATE PROJECT FOR THE REPAIR
AND REINSTALL OF ORGAN.
G E N E R A L B E L L N O T E S :
A. REMOVE EXISTING BELL AND DISASSEMBLE.
B. REMOVE ORGANIC MATERIAL AND PATINA FROM BELL AND ADDITIONAL METAL COMPONENTS
C. SEAL BELL WITH A CLEAR SEALER TO PREVENT RAPID OXIDATION
D. CAST IRON PIECES SHALL BE CLEANED/REPAIRED TO REMOVE PAINT, RUST, AND SCALE. POWDER COAT WITH MEDIUM
GLOSS BLACK
E. AFTER REFINISHING OF BELL AND ASSOCIATED COMPONENTS, REASSEMBLE. USE STAINLESS STEEL FASTENERS WHERE POSSIBLE. REPLACE WOOD BELL RUNNERS IF NEEDED WITH HIGH-QUALITY WOOD TIMBERS, AND SEAL.
F. REPAIR EXISTING WOOD WHEEL AND CLEAN / SEAL, OR REPLACE AS NEEDED.
G. TEST BELL FOR CORRECT BALANCE BY SWINGING, AND ADJUST AS NECESSARY
H. SUPPLY HIGH QUALITY ENGLISH CHANGE RING STYLE ROPE WITH WOOL SALLY FOR HAND RINGING FOR TOLLER AND
WHEEL
I. RETURN WHEEL TO BELL LANDING AND RE-INSTALL.
BELL LANDING
39' - 1 23/32"
WHEEL
BELL SUPPORT
BRONZE BELL
WOOD SUPPORT
WOOD
PEDESTAL
AE402
BELL LANDING
SHIPS LADDER TO FLOOR BELOW
BELL AND
PLATFORM
STEEL
POLE
STEEL POLE
STEEL
POLE
DISPLAY
SIGN
DISPLAY
SIGN
STEEL
BRACKETS
STEEL
BRACKETS
STEEL
BRACKETS
STEEL
BRACKETS
STEEL
BRACKETS
STEEL
BRACKETS
COPPER
FRAME
REPLACE
COPPER
TRIM
AE402
REPLACE
COPPER
TRIM
REPLACE
COPPER
TRIM
G E N E R A L O U T D O O R S I G N N O T E S :
A. DISASSEMBLE EXISTING SIGNS. CLEAN EXISTING OXIDATION, ORGANIC MATERIAL, AND PATINA OFF OF METAL
COMPONENTS.
B. EXISTING PAINTED STEEL POSTS TO REMAIN. REMOVE PAINT, DE-OXIDIZE AND CLEAN IN EXISTING PLACE TO "LIKE NEW"
FINISH. PAINT ALL EXISTING POSTS.
C. CLEAN OXIDATION FROM EXISTING TRIM AND REPLACE AS NECESSARY
D. SEAL AROUND GLAZING TO MAKE WATERTIGHT.
E. INSTALL NEW COPPER TRIM AT LOCATIONS NOTED IN DRAWING. INSTALL PRESSURE TREATED WOOD BLOCKING BEHIND
AREAS RECEIVING NEW COPPER TRIM.
F. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID TO ASSESS THE WORK REQUIRED AT THE OUTDOOR SIGN.
G. PROVIDE NEW FASTENERS OF COMPATABLE MATERIALS.
G E N E R A L C R O S S N O T E S :
A. NEW CAST ALUMINUM CROSS.
B. ORIENT NEW CROSS ORIENTATION TO FACE SOUTH.
C. CONNECT NEW CROSS WITH EXISTING LIGHTNING PROTECTION SYSTEM.
D. NEW BASE PLATE AND ESCUTCHEON PLATE TO CONNECT CROSS TO ROOF STRUCTURE.
E. CONTRACTOR SHALL SUBMIT CROSS CONNECTION DETAILS TO VA COR AND ARCHITECT FOR REVIEW AND APPROVAL
PRIOR TO CONSTRUCTION.
ROOF PLAN
59' - 1 15/32"
BASE PLATE
ESCUTCHEON
PLATE
CAST ALUMINUM
CROSS
2' - 6 1/2"
3"
BOLTED
CONNECTION
BASE PLATE
ESCUTCHEON
PLATE
BASE OF
CROSS
1' - 3"
REBUILD EXISTING COPPER
TRIM AS NECESSARY. MATCH
EXISTING TRIM PROFILE.
REBUILD EXISTING
BLOCKING AS
NECESSARY
EXISTING SIGN
FACE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:4
P
M
AE402
ENLARGED ORGAN & BELL PLANS,
ELEVATIONS AND DETAILS
Owner
07/30/2021 PQ DB
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/4" = 1'-0"
ENLARGED WEST ORGAN PLAN
1/4" = 1'-0"
ENLARGED NORTH ORGAN PLAN
1/2" = 1'-0"
BELL ELEVATION
1/4" = 1'-0"
BELL LANDING - FLOOR PLAN
1/2" = 1'-0"
SOUTH - ELEVATION - OUTDOOR SIGN
1/2" = 1'-0"
SOUTH - ELEVATION - CROSS
1 1/2" = 1'-0"
ENLARGED PLAN - CROSS BASE
6" = 1'-0"
SIGN TRIM
BASEMENT
-9' - 6 11/16"
ALUMINUM HANDRAIL AT
36" ABOVE STAIR
NOSING; ANODIZED
BRONZE
ALUMINUM GUARDRAIL AT
42" ABOVE STAIR NOSING;
ANODIZED BRONZE
BRICK LEDGE VARIES -
SEE ELEVATIONS
ACCESS GRATE
FOOTING. SEE
STRUCTURAL
DRAWINGS
AS501
WATERPROOFING MEMBRANE
4" GRANULAR FILL
4" GRANULAR FILL
4" GRANULAR FILL
PROTECTION BOARD
WATERPROOFING
MEMBRANE
CONCRETE LANDING
STEEL CHANNEL ANCHORED
TO WALL. REFER TO
STRUCTURAL DRAWINGS
FOUNDATION DRAINAGE
GRANULAR FILL
1/2" EXPANSION JOINT
MATERIAL, TYP.
12" CMU WALL - SEE STRUCTURAL
FOR REINFORCEMENT
EXISTING BRICK WALL
CONCRETE SIDEWALK - SEE
CIVIL DRAWINGS
AS501
N 52' - 2 25/32" E 38' - 5 1/8"
EL -1' - 0"
SLOPE:
1:20
N 25' - 7 1/4" E 50' - 11 9/32"
EL -2' - 0"
5' - 0"
6' - 5" 4' - 10" 7' - 2"
SLOPE:
1:20
SLOPE:
1:20
AS432
18' - 5"
AS432
116A
G E N E R A L N O T E S :
A. REPAIR DAMAGE TO SIDEWALKS, CURB AND GUTTER AS A RESULT OF CONSTRUCTION AND DEMOLITION ACTIVITIES.
B. REFER TO SHEETS AS431, AS432, AND AS501 FOR SECTIONS AND DETAILS OF NEW ENTRY RAMP AND STAIRS.
C. NEW BRICK AND MORTAR SHALL MATCH EXISTING BRICK AND MORTAR IN COLOR, PROFILE, AND CONSISTENCY.
D. EXISTING EXTERIOR WOOD BRACKETS, RAILINGS AND GUARDRAILS ARE SCHEDULED TO HAVE THE EXISTING PAINT REMOVED AND REPAINTED. THERE MAY BE WOOD MEMBERS THAT HAVE BEEN SEVERELY DAMAGED BY WEATHERING.
IDENTIFY THOSE INCIDENCES TO THE C.O.R. PRIOR TO THE START OF REFINISHING AND REPAINTING SO THE UNIT CAN BE
PROPERLY REPAIRED OR REPLACED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:0
P
M
AS431
ENLARGED RAMP - SECTIONS,
ELEVATIONS AND DETAILS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
D R A W I N G N O T E S :
1 CONCRETE PAD. BRUSHED CONCRETE FINISH.
2 CAST STONE CAP.
3 ALUMINUM GUARDRAIL.
4 CONCRETE STAIR.
5 CONCRETE RAMP.
1/2" = 1'-0"
RAMP SECTION
1/4" = 1'-0"
ENLARGED RAMP - MAIN ENTRANCE
UP
AS432
1' - 0"
ALUMINUM HANDRAIL AT 36"
ABOVE STAIR NOSING;
ANODIZED BRONZE
ALUMINUM GUARDRAIL AT 42"
ABOVE LANDING; ANODIZED
BRONZE
CAST STONE CAP
CAST-IN-PLACE CONCRETE
STAIRS
AS501
4' - 7" 6' - 6 3/4" 4' - 7"
15' - 8 3/4"
/2
CAST-IN-PLACE
CONCRETE LANDING
14' - 7 1/2"
RAISE EXISTING ELECTRICAL
MANHOLE COVER TO BE
FLUSH WITH NEW LANDING
STRIP EXISTING
PAINT FROM WOOD
RAILING - REPAINT TO
MATCH EXISTING
STEEL GRATE ACCESS PANEL
FLUSH WITH CONCRETE
SURFACE - PROVIDE HASP AT
GRATE
DNDN
DN
3' - 0"
AS432
AS432
104A
CAST STONE
CAP
ALUMINUM GUARDRAIL
CAST-IN-PLACE
CONCRETE STAIRS
BRUSHED CONCRETE,
TYPICAL
5' - 0" 1' - 1" 3' - 6"
/2
1' - 1"
FIRST FLOOR
0' - 0"
GRADE
-3' - 9"
CAST IN PLACE
CONCRETE STAIRS.
REFER TO STRUCTURAL
DRAWINGS
AS501
/2
FIRST FLOOR
0' - 0"
GRADE
-3' - 9"
AS432
3 5/8" BRICK
4" CAST IN PLACE
CONCRETE WALKWAY
4" GRANULAR FILL
GUARDRAIL
CONCRETE FOUNDATION.
REFER TO STRUCTURAL
DRAWINGS.
CONCRETE FOOTING.
REFER TO STRUCTURAL
DRAWINGS
LIMESTONE CAP
ARCHITECTURAL CONCRETE
FINISH
AS501
FIRST FLOOR
0' - 0"
GRADE
-3' - 9"
CONCRETE
SIDEWALK
CONCRETE STAIR.
REFER TO STRUCTURAL
DRAWINGS.
CONCRETE STAIRS.
REFER TO STRUCTURAL
DRAWINGS
ALUMINUM HANDRAIL AT 36" ABOVE
STAIR NOSING; ANODIZED BRONZE
CAST-IN-PLACE
CONCRETE LANDING
BRICK COLUMN
CAST STONE
CAP
ALUMINUM GUARDRAIL -
4" GRANULAR FILL
5 TREADS AT 11" EA. = 4' - 7"
R
IS
E
R S
A T
E A
ALUMINUM HANDRAIL BEYOND - REFER TO B/AE501
FOR DETAIL
FIRST FLOOR
0' - 0"
GRADE
-3' - 9"
AS432
/8
NEW BRICK AND MORTAR TO MATCH EXISTING BRICK
AND MORTAR IN COLOR, STYLE, AND PROFILE, TYP.
/8
1' - 0" 2' - 6 1/4" 1' - 0" 7' - 8 1/4" 1' - 0" 17' - 7 5/8" 1' - 0"
CONCRETE STAIRS
STONE CAP, TYP.
BRICK COLUMN, TYP.
ALUMINUM GUARDRAIL
AT 42" ABOVE LANDING;
ANODIZED BRONZE
ALUMINUM HANDRAIL
AT 36" ABOVE STAIR
NOSING, TYP.;
ANODIZED BRONZE 5'-0" MAX
EQ
FIRST FLOOR
0' - 0"
GRADE
-3' - 9"
CONCRETE
SIDEWALK
CONCRETE LANDING.
REFER TO STRUCTURAL
DRAWINGS.
CAST IN PLACE
CONCRETE STAIRS.
REFER TO STRUCTURAL
DRAWINGS
ALUMINUM HANDRAIL AT 36"
ABOVE STAIR NOSING
FOOTING DRAIN.
7 TREADS AT 12" EA. EQUALS 7' - 0"
R
IS
E
R S
A T
E A
. E Q
U A
L S
ALUMINUM HANDRAIL AT 36"
ABOVE RAMP
ALUMINUM GUARDRAIL AT 42"
ABOVE RAMP
TYP.
1' - 0"
TYP.
1' - 0"
T Y
P
CAST STONE
CAP
ALUMINUM HANDRAIL AT 36"
ABOVE STAIR NOSING
AS432
5' - 0" 1' - 1"
CAST-IN-PLACE
CONCRETE
STAIRS
CAST-IN-PLACE
CONCRETE LANDING
ALUMINUM GUARDRAIL AT
42" ABOVE STAIR NOSING
CAST STONE
CAP
CAST STONE CAP
ALUM. GUARDRAIL
AT 42" ABOVE
CONCRETE RAMP
ALUM. HANDRAIL
AT 36" ABOVE
CONCRETE RAMP
5' - 10"
CAST STONE
CAP
CAST STONE
CAP
ALUMINUM
GUARDRAIL AT 42"
ABOVE LANDING
ALUMINUM
GUARDRAIL AT 42"
ABOVE LANDING
CONCRETE LANDING
CAST-IN-PLACE
CONCRETE STAIR
AS432
3' - 0"2' - 0"
DN
FIRST FLOOR
0' - 0"
GRADE
-3' - 9"
V .I .F
ALUMINUM HANDRAIL AT 36"
ABOVE STAIR NOSING;
ANODIZED BRONZE
CONCRETE STAIRS
STONE CAP
BRICK COLUMN
ALUMINUM GUARDRAIL
AT 42" ABOVE LANDING;
ANODIZED BRONZE
5'-0" MAX
EQ
12' - 1"
FIRST FLOOR
0' - 0"
GRADE
-3' - 9"
CONCRETE
SIDEWALK
CONCRETE LANDING.
REFER TO STRUCTURAL
DRAWINGS.
CAST IN PLACE
CONCRETE STAIRS.
REFER TO STRUCTURAL
DRAWINGS
3' - 0"
ALUMINUM HANDRAIL AT 36" ABOVE
STAIR; ANODIZED BRONZE
G E N E R A L N O T E S :
A. REPAIR DAMAGE TO SIDEWALKS, CURB AND GUTTER AS A RESULT OF CONSTRUCTION AND DEMOLITION ACTIVITIES.
B. REFER TO SHEETS AS431, AS432, AND AS501 FOR SECTIONS AND DETAILS OF NEW ENTRY RAMP AND STAIRS.
C. NEW BRICK AND MORTAR SHALL MATCH EXISTING BRICK AND MORTAR IN COLOR, PROFILE, AND CONSISTENCY.
D. EXISTING EXTERIOR WOOD BRACKETS, RAILINGS AND GUARDRAILS ARE SCHEDULED TO HAVE THE EXISTING PAINT REMOVED AND REPAINTED. THERE MAY BE WOOD MEMBERS THAT HAVE BEEN SEVERELY DAMAGED BY WEATHERING.
IDENTIFY THOSE INCIDENCES TO THE C.O.R. PRIOR TO THE START OF REFINISHING AND REPAINTING SO THE UNIT CAN BE
PROPERLY REPAIRED OR REPLACED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:2
P
M
AS432
ENLARGED STAIRS - SECTIONS,
ELEVATIONS AND DETAILS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/4" = 1'-0" D
ENLARGED STAIR - MAIN ENTRANCE
1/4" = 1'-0"
A
ENLARGED STAIR - SOUTH TRANSEPT
1/2" = 1'-0"
SOUTH TRANSEPT STAIRS - LONG. SECTION
1/2" = 1'-0"
SOUTH TRANSEPT STAIRS - TRANS. SECTION
1/2" = 1'-0"
ENTRANCE STAIR - SECTION
1/4" = 1'-0" E
FRONT ENTRANCE - ELEVATION
1/2" = 1'-0"
STAIRS AT RAMP ENTRANCE
1/4" = 1'-0" B
ENLARGED STAIR - EAST TRANSEPT
1/4" = 1'-0"
C
ENLARGED STAIR - EAST ENTRANCE
1/4" = 1'-0" F
FRONT ENTRANCE - SIDE ELEVATION
1/2" = 1'-0"
ENTRANCE STAIR - EAST ENTRANCE
EXISTING FLOOR JOIST
EXISTING WOOD FLOOR
5" CONCRETE SLAB
EXISTING EXTERIOR BRICK
6" CMU
5/8" GYPSUM
BOARD CEILING
3/4" PLYWOOD
PAINTED WHITE
HOLLOW METAL
DOOR
/4
3/4" AIR GAP
COMPACTED BACKFILL
4" GRANULAR FILL
REINFORCED
THICKENED
SLAB EDGE
AE441
SS501
P
IT
NORTH CRAWL SPACE
AE441
EXISTING FLOOR JOIST
EXISTING WOOD FLOOR
5" CONCRETE SLAB
6" CMU
5/8" GYPSUM
BOARD CEILING
3/4" PLYWOOD
PAINTED WHITE
3/4" AIR GAP
COMPACTED BACKFILL
4" GRANULAR FILL
REINFORCED
THICKENED
SLAB EDGE
IT
NORTH CRAWL SPACE
FIRST FLOOR
0' - 0"
BALCONY
10' - 1 5/8"
TOWER LANDING
19' - 5 3/8"
NEW INTERIOR GYPSUM
FURRING. SEE FLOOR
PLAN FOR MAKE-UP OF
NEW CONSTRUCTION.
TWO LAYERS OF 1/4"
GYPSUM BOARD APPLIED
TO NEW METAL FRAMING
ON UNDERSIDE OF
EXISTING STRUCTURE
VERIFY STRUCTURE BEHIND
PLASTER AND LATHE
BALCONY
10' - 1 5/8"
TWO LAYERS OF 1/4"
GYPSUM BOARD APPLIED
TO NEW METAL FRAMING
ON UNDERSIDE OF
EXISTING STRUCTURE
5/8" GYPSUM BOARD
SALVAGED EXISTING
FIRE HOSE RACK,
EXISTING MOUNT
BRACKETS, AND
EXISTING BLOCKING
SHALL BE RE-
INSTALLED IN
PREVIOUS LOCATION.
G E N E R A L N O T E S :
A. ANY EQUIPMENT ITEM, ARCHITECTURAL ITEM OR ELECTRICAL LIGHT FIXTURE, THAT NEEDS TO BE REMOVED FROM THE BUILDING TO BE REPAIRED, REFURBISHED, OR REFINISHED SHALL BE PHOTOGRAPHED AND CATALOGED. THE CATALOG RECORD OF THESE ITEMS SHALL BE DELIVERED TO THE VA AT THE END OF EACH WORK WEEK OR AS
DIRECTED BY THE VA C.O.R.
B. INDICATIONS FOR REFINISHING OF WOODWORK OR FLOORING SHALL INCLUDE STRIPPING OF OLD FINISH OR PAINT DOWN TO BARE WOOD. SAND SMOOTH ALL SURFACES, SEAL WOOD, RESTAIN AND COAT WITH SPECIFIED VARNISH.
C. ALL EXTERIOR WOOD IS SCHEDULED TO RECEIVE NEW NEW PAINT - SEE FINISH SCHEULE AND LEGEND
D. ALL HARDWOOD FLOORS SHALL RECEIVE NEW STAIN - SEE FINISH SCHEDULE AND LEGEND.
E. SEAL AROUND ALL EXTERIOR PIPE OPENINGS IN THE EXTERIOR WALLS WITH EXTERIOR SEALANT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP. 12/31/2021C
U s e rs
\d u n n t\ D o c u m e n ts \F
F E
M t H o m e
C h a p e l_
B tj .d u n n
.r v t
/3
/2
:0
:0
P
M
AE441
ENLARGED INTERIOR SECTIONS
AND ELEVATIONS
Owner
07/30/2021 GL TD
CORRECT FCA DEFICIENCIES
HISTORICAL CHAPEL BLDG. 13
621-20-101
MT HOME, TENNESSEE
BID DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/2" = 1'-0"
IT ROOM - SECTION
1/2" = 1'-0"
IT ROOM - SECTION
1/4" = 1'-0"
STAGE FURRING SECTION
1/2" = 1'-0"
WEST BALCONY SECTION
| 07.10_AE201 - ELEVATIONS |
| AE201 - ELEVATIONS |
| 07.11_AE202 - ELEVATIONS |
| AE202 - ELEVATIONS |
| 07.12_AE203 - ELEVATIONS |
| AE203 - ELEVATIONS |
| 07.13_AE204 - ELEVATIONS |
| AE204 - ELEVATIONS |
| 07.14_AE301 - WEST CHAPEL - SECTIONS |
| AE301 - WEST CHAPEL - SECTIONS |
| 07.15_AE302 - NORTH CHAPEL - SECTIONS |
| AE302 - NORTH CHAPEL - SECTIONS |
| 07.16_AE311 - WALL SECTIONS |
| AE311 - WALL SECTIONS |
| 07.17_AE401 - ENLARGED RESTROOM PLANS, ELEVATIONS, AND DETAILS |
| AE401 - ENLARGED RESTROOM PLANS, ELEVATIONS, AND DETAILS |
| 07.18_AE402 - ENLARGED ORGAN & BELL PLANS, ELEVATIONS AND DETAILS |
| AE402 - ENLARGED ORGAN & BELL PLANS, ELEVATIONS AND DETAILS |
| 07.19_AS431 - ENLARGED RAMP - SECTIONS, ELEVATIONS AND DETAILS |
| AS431 - ENLARGED RAMP - SECTIONS, ELEVATIONS AND DETAILS |
| 07.20_AS432 - ENLARGED STAIRS - SECTIONS, ELEVATIONS AND DETAILS |
| AS432 - ENLARGED STAIRS - SECTIONS, ELEVATIONS AND DETAILS |
| 07.21_AE441 - ENLARGED INTERIOR SECTIONS AND ELEVATIONS |
| AE441 - ENLARGED INTERIOR SECTIONS AND ELEVATIONS |
| 07.22_AS501 - EXTERIOR DETAILS |
| AS501 - EXTERIOR DETAILS |
| 07.23_AE502 - INTERIOR DETAILS |
| AE502 - INTERIOR DETAILS |
| 07.24_AE601 - DOOR SCHEDULE AND DETAILS |
| AE601 - DOOR SCHEDULE AND DETAILS |
File details come from the government source that posted it. Updated .