mt-ep-yell2022-1-3_ali.pdf

PDF 159 KB Posted

Attached to
MT ERFO NP YELL 2022-1(3), Yellowstone NP Rescue Creek Bridge Replacement
Solicitation number
69056725R000010
Issued by

About this file

This is a Physical Data document containing horizontal and vertical alignment engineering specifications for the Yellowstone National Park Rescue Creek Bridge Replacement project under the Federal Highway Administration's Western Federal Lands Highway Division.

The document provides detailed alignment data for project MT ERFO NP YELL 2022-1(3), covering station MAIN05 from 100+00 to 104+20 (Pages 2-6). The horizontal alignment report details the geometric design elements including linear segments, circular curves, and coordinate positions with specific stations, northing/easting coordinates, tangent directions, curve radii, and lengths. Key horizontal elements include multiple curves with radii of 20 feet and 182 feet, with various tangent directions ranging from N84.689°E to N14.502°E. The vertical alignment report specifies elevation profiles with stations ranging from 5355.399 feet to 5380.577 feet elevation, including symmetrical parabolas, tangent grades varying from 0.012 to 0.141, and curve lengths. The engineering data was generated using design software and last revised on May 6, 2025, providing the technical foundation necessary for bridge replacement construction activities within Yellowstone National Park.

View the file

Other files

File Type Posted
Amendment A003.pdf PDF
QA_09-02-2025.pdf PDF
QA_08-27-2025.pdf PDF
Amendment A002.pdf PDF
QA_08-21-2025.pdf PDF
QA2_08-18-2025.pdf PDF
QA_08-18-2025.pdf PDF
Amendment A001.pdf PDF
QA_08-14-2025.pdf PDF
mt-ep-yell2022-1-3_xs.pdf PDF
RFP 69056725R000010_MT ERFO NP YELL 2022-1(3).pdf PDF
mt-ep-yell2022-1-3_Rescue Creek Bridge Final Foundation Memo.pdf PDF
mt-ep-yell2022-1-3_Rescue creek_control-sheet.xlsx XLSX spreadsheet
mt-ep-yell2022-1-3_plans_Final.pdf PDF
Physical Data.zip ZIP file
RescueCreek_Waterway_Hydraulics_Memo_95pct.pdf PDF
mt-ep-yell2022-1-3_earthwork.pdf PDF
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PHYSICAL DATA

for

FEDERAL HIGHWAY ADMINISTRATION

WESTERN FEDERAL LANDS HIGHWAY DIVISION

MT ERFO NP YELL 2022‐1(3)

Yellowstone NP Rescue Creek

Bridge Replacement

ALIGNMENT DATA

MAIN05 (100+00 to 104+20) Pages 2‐6

Horizontal Alignment Review Report Report Created: Thursday, May 29, 2025

Time: 7:44:31 AM

Project: Design IntlFt Description:

File Name: c:\pw-work\d0634773\mt-ep-yell2022-1-3_ALI_05.dgn Last Revised: 5/6/2025 14:51:45

Note: All units in this report are in feet unless specified otherwise.

Alignment Name: ALI05_Rescue Creek Alignment Description:

Alignment Style: Alignment\Baseline Station Northing Easting

Element: Linear

START ( START ) 100+00.00 1975237.911 2466851.826

HPI ( HPI ) 100+90.00 1975246.242 2466941.440

Tangential Direction: N84.689°E

Tangential Length: 90.000

Element: Linear

HPI ( HPI ) 100+90.00 1975246.242 2466941.440

HPI ( HPI ) 102+62.12 1975262.156 2467112.827

Tangential Direction: N84.695°E Tangential Length: 172.125

Element: Linear

HPI ( HPI ) 102+62.12 1975262.156 2467112.827

PC ( PC ) 102+72.12 1975263.080 2467122.784

Tangential Direction: N84.695°E Tangential Length: 10.000

Element: Circular

PC ( PC ) 102+72.12 1975263.080 2467122.784

HPI ( HPI ) 102+96.07 1975265.295 2467146.630

CC ( CC ) 1975282.995 2467120.935

PT ( PT ) 103+07.12 1975288.364 2467140.201

Radius: 20.000 Delta: 100.268° Left

Degree of Curvature (Arc): 286.479° Length: 35.000

Tangent: 23.948 Chord: 30.702

Middle Ordinate: 7.180

Page 1 of 2Horizontal Alignment Review Report

5/29/2025

External: 11.201 Back Tangent Direction: N84.695°E

Back Radial Direction: S5.305°E Chord Direction: N34.561°E

Ahead Radial Direction: N74.428°E Ahead Tangent Direction: N15.572°W

Element: Linear

PT ( PT ) 103+07.12 1975288.364 2467140.201

PC ( PC ) 103+18.24 1975299.068 2467137.218

Tangential Direction: N15.572°W Tangential Length: 11.112

Element: Circular

PC ( PC ) 103+18.24 1975299.068 2467137.218

HPI ( HPI ) 103+67.13 1975346.167 2467124.092

CC ( CC ) 1975347.927 2467312.537

PT ( PT ) 104+13.77 1975393.503 2467136.336

Radius: 182.000 Delta: 30.075° Right

Degree of Curvature (Arc): 31.481° Length: 95.532

Tangent: 48.894 Chord: 94.439

Middle Ordinate: 6.232 External: 6.453

Back Tangent Direction: N15.572°W Back Radial Direction: N74.428°E

Chord Direction: N0.535°W Ahead Radial Direction: S75.498°E

Ahead Tangent Direction: N14.502°E

Element: Linear

PT ( PT ) 104+13.77 1975393.503 2467136.336

END ( END ) 104+20.00 1975399.538 2467137.897

Tangential Direction: N14.502°E

Tangential Length: 6.233

Page 2 of 2Horizontal Alignment Review Report

Vertical Alignment Review Report Report Created: Thursday, May 29, 2025

Time: 7:45:32 AM

Project: Design IntlFt Description:

File Name: c:\pw-work\d0634773\mt-ep-yell2022-1-3_ALI_05.dgn Last Revised: 5/6/2025 14:51:45

Note: All units in this report are in feet unless specified otherwise.

Horizontal Alignment: ALI05_Rescue Creek Horizontal Description:

Horizontal Style: Alignment\Baseline

Vertical Alignment: MAIN05PRO Vertical Description:

Vertical Style: Alignment\Baseline Station Elevation

Element: Linear

START 100+00.00 5355.399

VPC 100+15.46 5355.586

Tangent Grade: 0.012 Tangent Length: 15.458

Element: Symmetrical Parabola

VPC 100+15.46 5355.586

VPI 100+22.96 5355.676

VPT 100+30.46 5356.685

Length: 15.000

Entrance Grade: 0.012 Exit Grade: 0.135 r = 100 * (g2 - g1) / L: 81.664 K = l / (g2 - g1): 1.225

Middle Ordinate: 0.230

Element: Linear

VPT 100+30.46 5356.685

VPC 100+63.90 5361.186

Tangent Grade: 0.135 Tangent Length: 33.445

Element: Symmetrical Parabola

VPC 100+63.90 5361.186

VPI 100+71.40 5362.195

VPT 100+78.90 5362.570

Page 1 of 3Vertical Alignment Review Report

Horizontal Alignment: ALI05_Rescue Creek Horizontal Description:

Horizontal Style: Alignment\Baseline Length: 15.000

Entrance Grade: 0.135 Exit Grade: 0.050 r = 100 * (g2 - g1) / L: -56.375 K = l / (g2 - g1): 1.774

Middle Ordinate: -0.159

Element: Linear

VPT 100+78.90 5362.570

VPC 103+48.50 5376.050

Tangent Grade: 0.050 Tangent Length: 269.600

Element: Symmetrical Parabola

VPC 103+48.50 5376.050

VPI 103+51.00 5376.175

PVRC 103+53.50 5376.000

VHP 103+50.59 5376.102

Length: 5.000 Entrance Grade: 0.050

Exit Grade: -0.070 r = 100 * (g2 - g1) / L: -240.000

K = l / (g2 - g1): 0.417 Middle Ordinate: -0.075

Element: Symmetrical Parabola

PVRC 103+53.50 5376.000

VPI 103+63.00 5375.335

VPT 103+72.50 5375.791

VLP 103+64.77 5375.606

Length: 19.000 Entrance Grade: -0.070

Exit Grade: 0.048 r = 100 * (g2 - g1) / L: 62.105

K = l / (g2 - g1): 1.610 Middle Ordinate: 0.280

Element: Linear

VPT 103+72.50 5375.791

VPC 103+85.50 5376.415

Tangent Grade: 0.048 Tangent Length: 13.000

Element: Symmetrical Parabola

Page 2 of 3Vertical Alignment Review Report

Horizontal Alignment: ALI05_Rescue Creek Horizontal Description:

Horizontal Style: Alignment\Baseline

VPC 103+85.50 5376.415

VPI 103+93.00 5376.775

VPT 104+00.50 5377.831

Length: 15.000

Entrance Grade: 0.048 Exit Grade: 0.141 r = 100 * (g2 - g1) / L: 61.888 K = l / (g2 - g1): 1.616

Middle Ordinate: 0.174

Element: Linear

VPT 104+00.50 5377.831

END 104+20.00 5380.577

Tangent Grade: 0.141 Tangent Length: 19.499

Page 3 of 3Vertical Alignment Review Report