This is a set of 100% construction documents for a new public restroom facility at McFee Park in Farragut, Tennessee, prepared by Johnson Architecture, Inc., with structural engineering by Elam Structural Engineers, mechanical and plumbing design by Engineering Services Group, and electrical design by Vreeland Engineers. The project scope encompasses the construction of a 212-square-foot, single-story restroom building classified as Type VB non-sprinklered occupancy with a maximum allowable height of 40 feet and floor area of 5,500 square feet. The facility will contain two individual restrooms (101 and 103), a mechanical room (102), and an entry area (104), all designed to comply with 2018 International Building Code standards and ADA accessibility requirements. The construction documents include detailed architectural floor plans, reflected ceiling plans, roof plans, door and window schedules, building elevations, interior elevations, building sections, and interior elevation details. Structural plans provide foundation details, roof framing plans, and connection details for the 8-inch concrete masonry unit walls with reinforced concrete footing, pre-engineered wood roof trusses at 24-inch on-center spacing, and structural steel columns. Mechanical plans show HVAC layout, water heater installation, and exhaust systems; plumbing plans detail fixture locations, waste and vent piping, and water supply lines; and electrical plans indicate lighting fixtures, power outlets, and branch circuits. The construction documents were revised on January 5, 2026, to incorporate Authority Having Jurisdiction comments, with the cover sheet dated November 24, 2025.
The construction documents specify detailed finish schedules including resinous flooring in restrooms, sealed concrete in the mechanical room, brushed concrete in the entry area, and various paint finishes using Sherwin Williams products. Interior and exterior materials include 8-inch split-face concrete masonry units with water-repellent sealer, 1-by-6 cedar nickel-gap tongue-and-groove siding, standing seam metal roofing, pre-finished aluminum guttering and downspouts, and pre-engineered wood trusses. Accessibility requirements are comprehensively detailed with specifications for grab bars, water closet spacing at 18 inches clear between wall and centerline, accessible sinks with 27-inch minimum knee space, lever-type hardware, door closers meeting state handicap codes, and signage including Braille and raised characters. The structural design is based on 2018 IBC with ASCE 7-16 loads, including ultimate design wind speed of 104 miles per hour, mapped seismic response acceleration values, and 10 pounds per square foot ground snow load. Foundation details show continuous concrete footings reinforced with #5 bars, a 4-inch concrete slab-on-grade with welded wire fabric reinforcement over 4 inches of crushed stone base, and anchor bolts for structural steel connections. All penetrations through rated partitions must be sealed with approved non-combustible material, and fire-rated access panels are required in ceilings and walls for mechanical, plumbing, and electrical access.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING CODE/ZONE ANALYSIS
KNOX COUNTY, TOWN OF FARRAGUT
PROJECT: A New Restroom Facility for:
McFee Park OWNER: Town of Farragut
CONTACT: Ron Oesteich, Parks & Recreation Director
ARCHITECT: Johnson Architecture, Inc.
2018 Davenport Road
Knoxville, Tenneessee 37920 phone: 865-671-9060
PROJECT
MANAGER: Emily Haire, AIA
Applicable Codes:
2018 International Building Code w/ adopting ordinance 2018 International Energy Conservation Code
2018 International Fire Code w/ adopting ordinance
2018 International Mechanical Code
2018 International Plumbing Code
2018 International Fuel and Gas Code 2018 NFPA 101 Life Safety Code
2018 ICC A117.1-2017, ANSI
2017 NFPA 70 National Electric Code
Occupancy Classification: U (Utility)
Type of Construction: TYPE VB (Non-Sprinklered)
Building Height and Area Limitations:
Allowable Building Height in Feet Above Grade Plane (Table 504.3):
Max. Height in Feet: 40'-0'
Allowable Number of Stories Above Grade Plane (Table 504.4):
Max. Number of Stories: 1
Allowable Area Factor in Square Feet (Table 506.2):
Max. Floor Area: 5,500 s.f.
Actual Building Height and Area:
Height in Feet: 13'-4"
Number of Stories: 1 Floor Area: Total = 212 s.f.
Fire-resistance Rating Requirements for Building Elements (Hours)
Table 601 Requirements:
Structural Frame Including Columns, Girders, Trusses: 0
Bearing Walls:
Exterior 0
Interior 0
Non-Bearing Walls:
Exterior {f} 0
Interior 0
Floor Construction:
Including Supporting Beams and Joists: 0
Roof Construction:
Including Supporting Beams and Joists: 0
Table 602
Fire-Resistance Rating Requirements for Exterior Walls based on Fire Seperation Distance {a}:
Fire Seperation Type of Group A, B, E, F-2, Distance (feet) Construction I, R{b}, S-2, U
< 5 {c} All 1 >/= 5 I-A 1
< 10 Others 1
>/= 10 I-A, I-B 1
< 30 II-B, V-B 0
Others 1 >/= 30 All 0
Table 716.1(2) Requirements:
Type of Assembly Required Assembly Min. Opening Protection
Rating (hours) Assembly (hours Fire Walls and Fire Barriers 4 3
Having a Fire-Resistance 3 3
Rating Greater than 1 Hour: 2 1-1/2
1-1/2 1-1/2
Fire Barriers of 1-Hour Fire-Resistance Rated Construction:
Shaft, Exit Enclosure Walls 1 1
Other Fire Barriers 1 3/4
Fire Partitions:
Corridor Walls 1 1/3 1/2 1/3
Other Fire Partitions 1 3/4
1/2 1/3
Exterior Walls 3 1-1/2
2 1-1/2 1 3/4
Smoke Barriers 1 1/3
Table 803.13 - Interior Wall and Ceiling Finish Requirements:
Group E/A - Sprinklered
Exit Enclosures and Exit Passageways: NO RESTRICTIONS Corridors: NO RESTRICTIONS
Rooms and Enclosed Spaces: NO RESTRICTIONS
Table 1016.1 - Exit Access Travel Distance:
Max. Exit Travel Distance: (300')
Max. Length of Dead End Corridor: (20')
Capacity of Means of Egress:
Minimum Stairway Width: (36")
Other Egress Components: XXX
Table 1019.1
Occupant Load Min. Number of Exits
(persons per story) (per story)
1-500 2 501-1,000 3 more than 1,000 4
ARCHITECT STRUCTURAL: MECHANICAL / PLUMBING
2018 Davenport Road Knoxville, TN 37920 8 6 5 . 6 7 1 . 9 0 6 0 jainc.com
ELECTRICAL:
A New Restroom Building for:
917 McFee Road, Farragut, TN 37934
McFEE PARK
Elam Structural Engineers P.O. Box 30799 Knoxville, TN 37931 865.607.3517
Engineering Services Group (ESG) 900 E Hill Avenue #350 Knoxville, TN 37915 865.522.0393
Vreeland Engineers 3107 Sutherland Avenue Knoxville, TN 37919 865.637.4451
11/24/2025
Sheet Number Sheet Name
Current Revision
Current Revision Date
00_GENERAL
G0.0 COVER 1 1/5/2025
G0.1 GENERAL INFORMATION
G0.2 ACCESSIBILITY REQUIREMENTS
04_ARCHITECTURAL SITE
AS1.1 SITE PLAN
06_ARCHITECTURAL
A1.1 PLANS, DOOR & WINDOW ELEVATIONS & SCHEDULES 1 1/5/2025
A3.1 BUILDING ELEVATIONS & INTERIOR ELEVATIONS
A4.1 BUILDING SECTIONS & DETAILS
08_STRUCTURAL
S001 STRUCTURAL NOTES
S002 STRUCTURAL NOTES
S100 STRUCTURAL PLANS
S201 STRUCTURAL DETAILS
09_MECHANICAL
M1.1 FLOOR PLAN - HVAC
10_PLUMBING
P1.1 FLOOR PLANS - PLUMBING - SCHEDULES & DETAILS
P2.1 PLUMBING SPECIFICATIONS
12_ELECTRICAL
E1.1 FLOOR PLAN - ELECTRICAL
DRAWING INDEXREGULATORY INFORMATIONVICINITY MAP
McFee Park
100% CONSTRUCTION DOCUMENTS
NOVEMBER 24, 2025
NOVEMBER 24, 2025
REVISION 1, 1/5/2025 - AHJ COMMENTS
ROOM NAME
150 SF
A 101
BUILDING SECTION
ENLARGED DETAIL
A101
SURFACE ELEVATION (PLAN)
X'-X"
XXX
LEVEL LINE (ELEVATION/SECTION)
MAIN LEVEL
0'-0"
COLUMN LINEWALL SECTION
INTERIOR ELEVATION
ROOM NUMBER AND NAME
REVISION NUMBER AND DATEXX XX XXXX
SLOPE
2% MAX
SLOPE OR DIRECTION INDICATOR
ACCESSORY TYPE
WINDOW TYPE
DOOR NUMBER - ROOM
NUMBER + LETTER IF MORE
THAN ONE DOOR
A
125A
GRAPHIC LEGEND
A101 1 Ref
R e f
1 Ref
R e fA101
1 Ref
1 Ref
R e f1
R e f
A101
1 Ref
R e f
1 Ref
R e f
EXTERIOR ELEVATION
A101
SIM
A101
SIM
20' - 0"ACT
A
CEILING MATERIAL AND HEIGHT
WALL TYPE
1. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS PREVAIL. IF DIMENSIONS ARE IN
QUESTION, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING
CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING WITH THE WORK
2. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE
PROJECT SITE PRIOR TO THE START OF ANY WORK. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR VERIFYING THE EXISTING CONDITIONS PRIOR TO BIDDING AND SHALL
BE FAMILIAR WITH ALL ASPECTS OF THE PROJECT, INCLUDING SITE UTILITIES
3. ALL DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF COLUMN, FACE OF MASONRY
OR CONCRETE, EDGE OF WALK OR FACE OF CURB UNLESS NOTED OTHERWISE. FOR
FURTHER DIMENSIONING SEE ENLARGED PLANS, SECTIONS, EXTERIOR ELEVATIONS,
INTERIOR ELEVATIONS, AND DETAILS
4. IN CASE OF DIMENSIONAL DISCREPANCIES BETWEEN ARCHITECTURAL AND
ENGINEERING DOCUMENTS CONTACT ARCHITECT FOR CLARIFICATION
5. ITEMS NOT INCLUDED IN GENERAL CONTRACTOR'S CONTRACT ARE MARKED "N.I.C."
(NOT IN CONTRACT) AND SHALL BE PERFORMED BY OWNER'S FORCES
6. THE GENERAL CONTRACTOR SHALL PROVIDE CHASES FOR MECHANICAL, PLUMBING,
AND ELECTRICAL SYSTEMS AS REQUIRED.
7. PIPING LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED IN
FURRED SPACES WITH THE EXCEPTION OF PIPING IN STAIRWAYS, EQUIPMENT ROOMS,
AND THE POWERHOUSE. THE GENERAL CONTRACTOR SHALL COORDINATE WITH OTHER
TRADES TO PROVIDE FURRING FOR PIPING INSTALLED IN FINISHED AREAS. THE
CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ARCHITECT PRIOR TO LOCATING
AND OR PROVIDING FURRED SPACES NOT INDICATED ON THE DRAWINGS
8. FOR ALL RATED AND / OR SMOKE PARTITIONS THE SURFACE AREA OF AN INDIVIDUAL
RECESSED METALLIC OUTLET, SWITCH BOX, ETC. SHALL NOT EXCEED 16 SQUARE INCHES.
THE AGGREGATE SURFACE AREA OF THE RECESSED BOXES SHALL NOT EXCEED 100
SQUARE INCHES PER 100 SQUARE FEET OF WALL AREA. RECESSED BOXES LOCATED ON
OPPOSITE SIDES OF WALLS OR PARTITIONS, REGARDLESS OF THEIR VERTICAL SEPARATION
ON THE WALL, SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24" MINIMUM
9. ALL RATED PARTITIONS SHALL BE TIGHTLY SEALED TO THE UNDERSIDE OF STRUCTURAL
DECK. INTEGRITY OF PARTITIONS SHALL BE MAINTAINED AT CORNERS AND AT
INTERSECTIONS OF OTHER PARTITION TYPES
10. PENETRATIONS IN RATED PARTITIONS FOR CONDUIT, PIPING OR OTHER COMBUSTIBLE
ITEMS SHALL BE FILLED WITH AN APPROVED NON-COMBUSTIBLE MATERIAL TO PROHIBIT
THE PASSAGE OF FIRE AND SMOKE
11. PROVIDE WOOD BLOCKING AS REQUIRED FOR ALL WALL MOUNTED EQUIPMENT OR
ACCESSORIES. NAILERS, BLOCKING AND OTHER ROUGH CARPENTRY ITEMS IN RATED
ASSEMBLIES SHALL BE TREATED FOR FIRE RESISTANCE
12. PROVIDE METAL STUD FRAMING AROUND ALL PENETRATIONS THROUGH METAL STUD /
GYPSUM BOARD ASSEMBLIES
13. GENERAL CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF TYPE SPECIFIED ARE
INSTALLED IN WALLS AND NON-ACCESSIBLE TYPE CEILINGS AND SOFFITS WHERE
ACCESS, SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING, OR ELECTRICAL ITEMS
MAY BE REQUIRED. ACCESS PANELS SHALL BE FIRE RATED TYPE EQUAL TO THE FIRE
RATING OF THE ASSEMBLY IN WHICH THEY OCCUR
14. CAULK AT JUNCTURE OF INTERIOR FACES OF DOOR FRAMES, VIEW WINDOW FRAMES,
EXTERIOR WINDOW FRAMES, MILLWORK, RECESSED TOILET ACCESSORIES, SURFACE
MOUNTED TOILET ACCESSORIES, ETC. WITH ADJACENT MATERIAL EVEN IF JOINT MAY
NOT BE VISIBLE
15. ALL CASEWORK DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO FABRICATION
16. ALL ACCESSIBLE WATER CLOSETS SHALL BE MOUNTED WITH IS 1'-6" CLEAR BETWEEN FACE
OF ADJACENT SIDE WALL AND CENTERLINE OF WATER CLOSET EXCEPT AS DIMENSIONED
OTHERWISE
17. GENERAL CONTRACTOR SHALL COORDINATE ALL EXTERIOR WINDOW SIZES AND
PLACEMENT WITH THE EXTERIOR SKIN SUPPLIER
18. GENERAL CONTRACTOR SHALL LAY OUT ALL PARTITIONS AND VERIFY ACCEPTANCE OF
LAYOUT WITH ARCHITECT PRIOR TO COMMENCEMENT OF WORK
19. FIELD MEASUREMENTS: WHERE WORK IS INDICATED TO FIT TO OTHER CONSTRUCTION,
VERIFY DIMENSIONS OF OTHER CONSTRUCTION BY FIELD MEASUREMENT PRIOR TO
FABRICATION AND INDICATE MEASUREMENTS ON SHOP DRAWINGS. COORDINATE THE
FABRICATION SCHEDULE WITH CONSTRUCTION PROGRESS TO AVOID DELAYING THE
WORK
20. LOCATE CONCEALED FRAMING, BLOCKING, AND REINFORCEMENT THAT SUPPORT THE
WORK BY FIELD MEASUREMENTS BEFORE BEING ENCLOSED AND INDICATE
MEASUREMENTS ON SHOP DRAWINGS
21. ESTABLISHED DIMENSIONS: WHERE FIELD MEASUREMENTS CANNOT BE MADE WITHOUT
DELAYING THE WORK, ESTABLISH DIMENSIONS AND PROCEED WITH FABRICATING WORK
WITHOUT FIELD MEASUREMENTS. PROVIDE ALLOWANCE FOR TRIMMING ON SITE AND
COORDINATE CONSTRUCTION TO ENSURE THAT ACTUAL DIMENSIONS CORRESPOND TO
ESTABLISHED DIMENSIONS. IF WORK PROCEEDS WITHOUT FIELD MEASUREMENTS THE
GENERAL CONTRACTOR ASSUMES RESPONSIBILITY FOR ANY CORRECTIVE ACTION
NECESSARY FOR COORDINATION OF ALL WORK
22. SEAL ALL PENETRATIONS IN THE EXTERIOR BUILDING ENVELOPE AIR TIGHT AT BOTH THE
INTERIOR (VAPOR RETARDER AND GYPSUM BOARD) AND EXTERIOR (SHEATHING AND
BUILDING WRAP) FACES
GENERAL NOTES
DATE:
PROJECT NO:
A N e w
R e st ro o m
B u ild in g f o r:
M c
F e e R o a d F a rr a g u t, T
N
M c
F E E P
A R
K
11/24/2025
253128
G0.1
GENERAL
INFORMATION
11/24/2025
ABBREVIATIONS
& AND
@ AT
A.H.U. AIR HANDLING UNIT
A.P. ACCESS PANEL
A/C AIR CONDITIONING
ABV ABOVE
ACOUST ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADDL ADDITIONAL
ADJ ADJUSTABLE, ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ARCH ARCHITECT(URAL)
B.M. BENCH MARK
BD BOARD
BET BETWEEN
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOC BOTTOM OF CURB
BOW BOTTOM OF WALL
BRG BEARING
BRG PL BEARING PLATE
BTM BOTTOM
BUR BUILT UP ROOF
C.I. CURB INLET
C.I.P. CAST-IN-PLACE CONCRETE
CAB CABINET
CB CATCH BASIN
CEM CEMENT
CHNL CHANNEL
CJ CONTROL JOINT
CLG CEILING
CLO CLOSET
CLR CLEAR(ANCE)
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONF CONFERENCE ROOM
CONST CONSTRUCTION
CONT CONTINUOUS/CONTINUE
CONTR CONTRACTER
COORD COORDINATE
CORR CORRUGATED, CORRIDOR
CPT CARPET
CRS COURSE(S)
CT CERAMIC TILE
CTR CENTER
CTSK, CS COUNTERSUNK
DA DOUBLE ACTING
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGRAM
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DW DISH WASHER
DWG DRAWING
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION & FINISH
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION, ELEVATOR
EMER EMERGENCY
ENO EXCEPT NOTED OTHERWISE
EOC END OF CURB
EOP EDGE OF PAVEMENT
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION, EXPOSED
EXT EXTERIOR
ABBREVIATIONS
FA FIRE ALARM
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISH FLOOR ELEVATION
FFL FINISH FLOOR LINE
FH FLAT HEAD
FHC FIRE HOSE CABINET
FIN FINISH(ED)
FIN FL FINISH FLOOR
FLR FLOOR(ING)
FLUOR FLUORESCENT
FOF FACE OF FINISH
FOS FACE OF STUD
FRMG FRAMING
FS FIRE STANDPIPE
FSTN FASTEN(ED)
FTG FOOTING
FUR FURR (ED) ()ING
GA GAUGE/GAGE
GALV GALVANIZED
GCMU GLAZED CONCRETE MASONRY UNIT
GFRC GLASS FIBER-REINFORCED CONCRETE
GL GLASS/GLAZING
GL BLK GLASS BLOCK
GR GRADE
GR GUARD RAIL
GYP BD GYPSUM BOARD
H/C HANDICAP
HB HOSE BIB
HC HOLLOW CORE
HD HAND/HEAD
HDR HEADER
HDW HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HR HANDRAIL
HS HORIZONTAL SIDING
HSTWY HOISTWAY
ID INSIDE DIAMETER
INSUL INSULATE(D)(ING)(ION)
INT INTERIOR
INV INVERT
IPS IRON PIPE SIZE
JC JANITOR'S CLOSET
JNT JOINT
JST JOIST
KIT KITCHEN
L LENGTH, LONG
L.H. LEFT HAND
LAM LAMINATE(D)
LAM FL LAMINATE FLOORING
LAV LAVATORY
LL LIVE LOAD
LP LOW POINT
LTL LINTEL
LVR LOUVER
LVT LUXURY VINYL TILE
MACH MACHINE, MACHINERY
MAR MARBLE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANIC(AL)
MFR MANUFACTURER ®
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
MULL MULLION
N/A NOT AVAILABLE
NC NONCOMBUSTIBLE
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
O-O OUT TO OUT
O.F.C.I. OWNER FURNISHED CONTRACTOR INSTALLED
O.F.O.I. OWNER FURNISHED OWNER INSTALLED
ABBREVIATIONS
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OVERHEAD
OP. HD. OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
P.T. PRESSURE TREATED
PC PRECAST
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTIC, PLASTER
PLUMB PLUMBING
PLY PLYWOOD
PNL PANEL
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PTD PAINTED
PVC POLYVINYL CHLORIDE
PVT PAVEMENT
Q.T. QUARRY TILE
R RISER, RADIUS
R.C.P. REINFORCED CONCRETE PIPE
R.H. RIGHT HAND
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFERENCE
REF REFRIGERATOR
REFL REFLECTED
REINF REINFORCED
REQ'D REQUIRED
RES RESILIANT
RES. FL. RESINOUS FLOORING
RM ROOM
RO ROUGH OPENING
ROW, R/W RIGHT OF WAY
RVL REVEAL
RWL RAINWATER LEADER
SCH SCHEDULE
SCWD SOLID CORE WOOD DOOR
SDG SIDING
SECT SECTION
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION(S)
SS SOLID SURFACE, SERVICE SINK
SST STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
T TREAD
T&G TONGUE AND GROOVE
T.B. TACK BOARD
T.O.S. TOP OF STEEL
T.V. TELEVISION
TC TOP OF CURB
TEL TELEPHONE
TEMP TEMPERED, TEMPORARY
TERR TERRAZZO
THK THICK(NESS)
TLT TOILET
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UR URINAL
UTIL UTILITIES
VB VAPOR BARRIER, VINYL BASE
VCT VINYL COMPOSITION TILE
VEJ VENEER EXPANSION JOINT
VERT VERTICAL
VIF VERIFY IN FIELD
VIN VINYL
W WIDE, WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WATER HEATER
WR WATER RESISTANT
WWF WELDED WIRE FABRIC
REVISIONS
REV # Description Date
X 24" PREF. 18" MIN
M
IN
Y
M
IN
Y
24" MIN.
X
24" MIN.
X
M
IN
Y
M
IN
Y
54" MIN.
M
IN
12" MIN.
X
NOTE:
Y=48" MIN. IF DOOR HAS
CLOSER
NOTE:
Y=48" MIN. IF DOOR HAS
BOTH LATCH AND CLOSER
NOTE:
Y=54" MIN. IF DOOR HAS
CLOSER
NOTE:
X=36" MIN IF Y=60"
X=42" MIN IF Y=54"
NOTE:
X=12" IF DOOR HAS BOTH A
CLOSER AND LATCH
LATCH SIDE APPROACH HINGE SIDE APPROACH FRONT APPROACH
24"
MAX
2' - 0" 2' - 6"
M
A X
MAX
10" 2' - 6"
4' - 0"
20" MAX
4' - 0"
M
A X
M
A X
4' - 0" >20"-25" MAX
MIN
4' - 0"
M
IN
4' - 0"
20" MAX
M
A X
CLEAR FLOOR SPACE
PARALLEL APPROACH
HIGH AND LOW SIDE
REACH LIMITS
MAXIMUM SIDE REACH OVER
AN OBSTRUCTION
MAXIMUM FORWARD
REACH OVER AN
OBSTRUCTION
HIGH FORWARD
REACH LIMIT
ACCESSIBLE REACH REQUIREMENTS
PROPORTIONS
INTERNATIONAL SIGN
OF ACCESSIBILITY
PROPORTIONS
INTERNATIONAL SIGN
OF ACCESSIBILITY
PROPORTIONS
INTERNATIONAL SIGN
OF ACCESSIBILITY
WOMEN RESTROOMS
MEN
INTERNATIONAL
TDD SYMBOL
INTERNATIONAL
SYMBOL OF ACCESS
FOR HEARING
IMPAIRED
RAISED 5/8"
LETTERS AND NUMBERS
1. WIDTH AND HEIGHT RATION BETWEEN 3:5 AND 1:1
2. STROKE WIDTH TO HEIGHT BETWEEN 1:5 AND 1:10
3. CONTRAST CHARACTERS AND SYMBOLS WITH BACKGROUND.
4. SANS SERIF CHARACTERS.
SIGNS/ PICTOGRAMS
1. PICTOGRAMS/PICTORIAL SYMBOL SIGNS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED
DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION SHALL BE 6" MINIMUM IN HEIGHT.
2. CHARACTERS AND BACKGROUNDS SHALL BE OF NON-GLARE CONTRASTING COLORS.
3. SIGNS/ PICTOGRAMS SHALL BE INSTALLED ON THE WALL ADJACENT TO DOOR LEADING TO THE ROOM OR SPACE THEY
DESCRIBE AND AT 60" A.F.F. TO SIGN CENTERLINE AND WHERE A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT
ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE DOOR SWING AREA. VERTICAL CLEARANCE AT
SUSPENDED SIGNS WITH MINIMUM HEADROOM OF 80" REQUIRE MINIMUM 3" CHARACTER HEIGHT MEASURED BY USING
UPPERCASE "X". CHARACTERS AND NUMBERS SHALL BE SIZED ACCORDING TO VIEWING DISTANCE FROM WHICH READ.
SIGN LOCATIONS
1. ALL ACCESSIBLE ENTRANCES IDENTIFIED WITH MINIMUM OF ONE STANDARD SIGN.
2. ADDITIONAL DIRECTIONAL SIGNS ALONG ACCESSIBLE PATH OF TRAVEL ARE REQUIRED.
3. BUILDING REMODELED TO PROVIDE ACCESSIBLE SANITARY FACILITIES FOR PUBLIC USE SHALL HAVE INFORMATION POSTED IN
THE LOBBY AS PART OF THE BUILDING DIRECTORY.
INTERNATIONAL SYMBOL OF ACCESSIBILITY
1. STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES.
2. WHITE FIGURE ON BLUE BACKGROUND, COLOR #15090 ON FEDERAL STANDARD #595A.
3. WHEN ENFORCING AGENCY DETERMINES, IF APPROPRIATE, SPECIAL DESIGN AND COLORS MAY BE APPROVED.
BRAILLE
1. USE CONTRASTED GRADE 2 BRAILLE. DOTS TO BE 0.1 INCH ON CENTER IN EACH CELL.
2. 0.2 INCH SPACE BETWEEN CELLS. 17. DOTS RAISED MINIMUM 0.025 INCH ABOVE BACKGROUND.
NOTES:
1. DOOR SIGN SHALL BE CENTERED ON DOOR AND MOUNTED 60" A.F.F. AT THE CENTER OF THE SIGN. ONLY WHEN USING
ADHESIVE CAULK EDGES W/ CLEAR SILICONE.
2. ROOM SIGNS SHALL HAVE RAISED, BRAILED CHARACTERS AND PICTORIAL (PICTOGRAMS) SIGNS. LETTERS OR NUMBERS SHALL
BE RAISED 1/32" IN UPPERCASE SANS SERIF FONT AND SHALL BE ACCOMPANIES BY GRADE 2 BRAILLE RAISED CHARACTERS
5/8" HIGH MIN., 2" MAX.
3. THE FINISH CONTRAST OF THE SIGN CHARACTERS AND BACKGROUND SHALL BE EGGSHELL, MATTE, OR OTHER NON-GLARE
FINISH.
4. CHARACTERS AND SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR.
EQ. EQ.
MOUNTING A DOOR & WALL MOUNTING AT WALL (NO DOOR)
1' - 0"
WOMEN
TO
C
E N
TE
R
O F S
IG
N
BRAILLE SIGN
WALL SIGN
WHERE OCCURS
WOMEN
BRAILLE SIGN
TYPICAL ROOM ID
SIGN
TYPICAL DOOR SIGN
WHERE OCCURS
OPEN
NOTES
1. AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A15610-1985. SLOW OPENING,
LOW-POWERED, AUTOMATIC DOORS SHALL COMPLY WITH ANSI A15619-1984. DOORS
SHALL TAKE AT LEAST THREE SECOND TO OPEN BEFORE BACK CHECKING AND NOT REQUIRE
MORE THAN A 15-POUND FORCE TO STOP THE DOOR MOVEMENT. THE DOOR-OPENING
FORCE OF A POWER-ASSISTED DOOR SHALL COMPLY WITH SECTION C-5212. ITS CLOSING
SHALL CONFORM WITH ANSI.
DOOR TYPES
1. MINIMUM 10" HIGH SMOOTH SURFACE AT DOOR BOTTOM, EITHER ATTACHED PANEL OR
BOTTOM RAIL.
HARDWARE
1. OPENS FROM INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT.
2. MOUNTED 36" TO 42" A.F.F.
3. OPENS BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT REQUIRING GRASPING)
4. MAXIMUM 85 LBS EFFORT TO OPERATE EXTERIOR DOOR, 5 LBS FOR INTERIOR.
10" MIN. BOTTOM RAIL OR
PROVIDE KICK PLATE
36" TO 42" LEVER OR "U"
SHAPED HANDLE
BABY
CHANGING
STATION
M
A X
MIRROR FIRE
EXTINGUISHER
CABINET
SURFACE MOUNTED
PAPER TOWEL
DISPENSER
ACCESSIBLE
TOILET PAPER
DISPENSER
SURFACE MOUNTED
SOAP DISPENSER
CL
COAT HOOK MOP STRIPFEMININE
NAPKIN
RECEPTACLE
FEMININE
NAPKIN
DISPENSER
BTM. OF REFLECTIVE
SURFACE
DIM. TO
OUTLET
DIM. FROM FRONT
OF TOILET
M
A X
SURFACE IN OPEN
POSITION
OPEN POSITION
SURFACE MOUNTED
HAND DRYER
M
A X
M
A X
9" MAX
7" MIN
M
IN
TO
P
O F H
O O
K
M
A X
M
IN
M
A X
M
A X
K N
E E S
P A
C E
M
IN
TO
P
O F R
A C
K
HC
CL
CL
WATER
COOLER
ACCESSIBLE
URINAL
STANDARD
URINAL
ACCESSIBLE
WATER CLOSET
STANDARD
WATER CLOSET
ACCESSIBLE
SINK
CL
CL CL
CL
ACCESSIBLE
GRAB BARS
CLR. MIN
30"
M
IN
MIN
1' - 3"
M
IN
M
A X
17" MIN
M
IN
6" MAX 8" MIN
M
IN
M
A X
18" MAX
16" MIN
6" 36" MIN
12" MIN 24" MIN
MIN
54"
12" MAX 42" MIN
M
A X
M
IN
M
IN
M
A X
M
IN
41" MAX
39" MIN
M
A X
MIN
30"
M
IN
M A
X
24"
M
IN
M A
X
MIN
30"
36" MIN
9" MAX
7" MIN
41" MAX
39" MIN
TO WALL
18"
1. SIGNS MARKING ACCESSIBLE PARKING SPACES SHALL BE INSTALLED SO THAT THE
BOTTOM OF THE SIGN IS 6'-8" MINIMUM HEIGHT. ONE OR MORE SHALL IDENTIFY A VAN
ACCESSIBLE SPACE
2. LISTENING SYSTEMS SHALL BE PROVIDED IN ASSEMBLY AREAS IN ACCORDANCE WITH
2006 IBC SECTION 1108.2.6 AND SECTION 706 OF THE 2003 ICC/ANSI A117.1
3. WHEELCHAIR SPACES SHALL BE PROVIDED IN ASSEMBLY AREAS IN ACCORDANCE WITH
2006 IBC SECTION 1108.2.8 AND SECTION 802 OF 2003 ICC/ANSI A117.1. REFER TO
ARCHITECTURAL FURNITURE PLAN SHEETS FOR LOCATIONS
4. COMPANION SEATS AND DESIGNATED AISLE SEATS SHALL BE PROVIDED IN
ACCORDANCE WITH 2006 IBC SECTION 1108.2.4 AND SECTION 802.7 OF 2003 ICC/ANSI
A117.1. REFER TO ARCHITECTURAL FURNITURE PLAN SHEETS FOR LOCATIONS
5. ALARMS AND CONTROLS SHALL BE PROVIDED IN ACCORDANCE WITH 2012 IBC
CHAPTERS 9 AND 11 AND 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
6. STORAGE AND LOCKER FACILITIES SHALL BE PROVIDED IN ACCORDANCE WITH 2012 IBC
CHAPTERS 9 AND 11 AND 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
7. RECREATIONAL FACILITIES SHALL BE PROVIDED IN ACCORDANCE WITH 2006 IBC
SECTION 1109.14
8. ALL RAMPS SHALL BE A MAXIMUM OF 1" RISE PER FOOT OF SLOPE
9. ALL DOOR HARDWARE TO BE ADA COMPLIANT. ALL PANIC HARDWARE SHALL BE
MOUNTED NO HIGHER THAN 48" A.F.F.
10. ALL CROSS SLOPES THAT ARE A PORTION OF THE ACCESSIBLE ROUTE SHALL BE A
MAXIMUM OF 2%
11. ALL ACCESSIBLE PATHS OF TRAVEL TO BE LEVEL. KITCHEN FLOOR SLOPES UNDER THE
PATH OF TRAVEL TO BE LESS THAN 1:20. CROSS SLOPES SHALL NOT BE GREATER THAN 1:48
OR 1/4" PER FOOT
12. ARROWS INDICATE DIRECTION OF FLOOR SLOPE TO DRAINS - SLOPE SHALL NOT EXCEED
2%
13. TELEVISIONS SHALL BE MOUNTED NO LOWER THAN 80" A.F.F. (INCLUDING CORDS)
TELEVISIONS SHALL BE EQUIPPED AND UTILIZE CLOSED CAPTIONING, MINIMUM OF ONE
SHALL BE SET TO DISPLAY
14. TABLES SHALL BE A MINIMUM OF 27" CLEAR A.F.F. AND HAVE A CLEAR AREA AT LEAST 19"
DEEP
15. COAT HOOKS IN ACCESSIBLE TOILET STALLS SHALL BE MOUNTED TO THE WALL OF THE
TOILET STALL AT 48" A.F.F.
16. FLUSH VALVES ON TOILET FIXTURES SHALL BE LOCATED ON THE WIDE SIDE OF THE FIXTURE
STALL AND UTILIZE NO GREATER THAN 5 LBS OF FORCE TO OPERATE
17. ALL THRESHOLDS, FLOOR LEVEL CHANGES AND FLOOR TRANSITIONS SHALL NOT EXCEED
1/2" IN HEIGHT AND SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2
ACCESSIBILITY NOTES
DATE:
PROJECT NO:
A N e w
R e st ro o m
B u ild in g f o r:
M c
F e e R o a d F a rr a g u t, T
N
M c
F E E P
A R
K
11/24/2025
253128
G0.2
ACCESSIBILITY
REQUIREMENTS
11/24/2025
ARCHITECTURAL SITE SHOWN IS BY OTHERS, THIS PLAN IS
FOR REFERENCE ONLY FOR NEW RESTROOM BUILDING
LOCATION. REFERENCE ALL OTHER DRAWINGS IN THIS
PACKAGE FOR PROJECT SCOPE.
DOG PARK AREA, N.I.C.
EXISTING PARKING
AREA, N.I.C.
SCOPE OF WORK:
NEW RESTROOM STRUCTURE,
COORDINATE ALL CONNECTIONS
WITH EXISTING SITE CONDITIONS
DATE:
PROJECT NO:
A N e w
R e st ro o m
B u ild in g f o r:
M c
F e e R o a d F a rr a g u t, T
N
M c
F E E P
A R
K
11/24/2025
253128
AS1.1
SITE PLAN
11/24/2025
1" = 10'-0"AS1.1
1 ARCHITECTURAL SITE PLAN
1. COORDINATE WITH APPLICABLE DIMENSIONS AND DETAILS ON OTHER SHEETS
2. SEE SHEET G0.1 AND G0.2 FOR ABBREVIATIONS, SYMBOLS, GENERAL NOTES AND TYPICAL
ACCESSIBLE MOUNTING HEIGHTS
3. FURNISH AND INSTALL FIRE EXTINGUISHERS AS REQUIRED BY AHJ MINIMUM REQUIRED
PER 75'-0" TRAVEL OR 1 PER 6,000 SF OF BUILDING AREA
4. PROVIDE ROUGH HARDWARE, ETC. AS REQUIRED TO MOUNT EQUIPMENT
5. PROVIDE POSITIVE SLOPE TO ALL FLOOR DRAINS
FLOOR PLAN NOTES
A3.1
A3.1
A3.1 4
A3.11
22' - 8"
8' - 8" 5' - 4" 7' - 4" 1' - 4"
"R 2' �
6"R 2
59.63 SF
RESTROOM
101 43.00 SF
MECHANICAL
59.63 SF
RESTROOM
102 103
BABY CHANGING STATION
ELECTRICAL PANEL
WOOD WALL SHELF , PAINTED
A3.15
ELECT. HAND DRYER
HOSE BIB
A3.16
WINDOW ABOVE
AA
HBHB
MOP HOLDER
A4.1
A4.1
BRUSHED CONCRETE
FINISH
MOP SINK, SEE PLUMB.
8" REINFORCED CMU,
CELLS FILLED AS REQ'D BY
STRUCTURAL W/LOXON
40% SILANE WATER
REPELLENT SEALER (CLEAR),
TYP. - INTERIOR FINISH PER
FINISH SCHEDULE
97.33 SF
ENTRY
1' - 4"
1' - 4"
" 3
FD
FD
HOSE BIB
EXTERIOR RATED FIRE
EXTINGUISHER & CABINET
NOTE: PROVIDE -R- FIRE SAFETY
SYMBOL SIGN ON FRONT OF BUILDING,
COORDINATE FINAL LOCATION W/ AHJ
A3.1
A3.1
A3.1 4
A3.11
4' - 4" 7' - 0" 7' - 0" 4' - 4"
E Q
E Q
EQ EQ
GRADE B+, NEAR CLEAR
CEDAR NICKEL GAP T&G
CEILING, SEALED - FIX TO
UNDERSIDE OF CLG TRUSS
A4.1
A4.1
GRADE 'A' PLYWOOD CLG
W/ BATTENS, PAINTED - FIX TO
UNDERSIDE OF CLG TRUSS
TUBE STEEL BEAMS &
COLUMNS, PAINTED
"1' - 10"
" 1' - 10" 1' - 0"
1' - 0"
8"8"
E Q
E Q
EQ EQ EQ EQ
1' - 0" 1' - 0"
CEILING HEATER, SEE
MECHANICAL
A3.1
A3.1
A3.1 4
A3.11
4" / 1'-0"4" / 1'-0"
STA�DI�G SEA� �ETA�
R��FI�G �� WEATHER BARRIER
�� EXT� GRADE SHEATHI�G ��
PRE�E�GI�EERED W��D TRUSSES
PRE�FI�ISHED A�U�� B�X
GUTTERI�G & RECTA�GU�AR
D�W�SP�UTS (D�S�)
A4.1
A4.1
D.S. D.S.
D�W�SP�UTS (D�S�) T� BE
B��TED RU�
U�DERGR�U�D T�
DAY�IGHT PER R��F ��TES
R
ID
G E
WALL MOUNTED ELECTRIC HEATER, SEE MECHANICAL
PLYWOOD CEILING -- PTD FINISH SEE
FINISH SCHEDULE
EXHAUST FAN, SEE MECHANICAL
RECESSED LIGHT FIXTURE
TRANSFER GRILL, SEE MECHANICAL
REFLECTED CEILING PLAN LEGEND
GRADE B+, NEAR CLEAR CEDAR T&G CEILING, SEALED
SURFACE MOUNTED LED FIXTURE
1. COORDINATE WITH APPLICABLE NOTES AND DIMENSIONS ON OTHER SHEETS.
2. ALL SOFFITS AND CEILING HEIGHTS INDICATED SHALL BE MEASURED FROM BOTTOM OF
FINISH MATERIAL TO FINISH FLOOR ELEVATION DIRECTLY BELOW.
3. ALL DIMENSIONS SHOWN ON REFLECTED CEILING PLANS ARE FINISHED DIMENSIONS.
4. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF APPROPRIATE SIZE AND TYPE
ARE INSTALLED IN WOOD CEILING ASSEMBLIES, SOFFITS, AND IN OTHER NON-
ACCESSIBLE TYPE AREAS WHERE ACCESS, SERVICE OR ADJUSTMENT TO MECHANICAL,
PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE FIRE
RATED EQUAL TO ANY RATING OF THE CEILING OR SOFFIT IN WHICH THEY OCCUR.
5. ONLY CEILING MOUNTED EXIT LIGHTING IS SHOWN ON THE REFLECTED CEILING PLANS.
SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF WALL MOUNTED EXIT LIGHTING.
6. CONTRACTOR TO COORDINATE WITH ARCHITECT AND OWNER ALL FIXTURE SELECTIONS
AND FINISHES PRIOR TO INSTALLATION.
7. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED CEILING
PLANS WITH THE ELECTRICAL LIGHTING PLANS AND MECHANICAL PLANS. GENERAL
CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERROR, INCONSISTENCY OR
OMISSION THAT IS DISCOVERED.
8. PROVIDE STRUCTURAL SUPPORT FOR CEILING MOUNTED EQUIPMENT AS REQUIRED.
9. ALL WOOD CEILINGS IN WET AREAS SHALL BE PAINTED, TYP.
10. PROVIDE CEILING CONTROL JOINTS WITH BATTENS AS INDICATED.
REFLECTED CEILING PLAN NOTES
1. ARROWS INDICATE DOWNWARD ROOF SLOPE, 1/4" PER FOOT MINIMUM.
2. PROVIDE VENTS THROUGH ROOF AS INDICATED FOR PLUMBING SYSTEMS. LOCATIONS
TO BE NO CLOSER THAN 10'-0" TO ANY AIR INTAKE.
3. D.S. = DOWNSPOUT
4. ALL DOWNSPOUTS TO TIE INTO PVC 'BOOT' AND ROUTED UNDERGROUND TO DAYLIGHT
AREA WITH APPROPRIATE SOIL STABILIZING ELEMENTS (GRID, ROCK, ETC.) TO ELIMINATE/
MINIMIZE EROSION, OR CONNECTED TO EXISTING STORM PIPING WHERE ADJACENT.
5. ALL GUTTERS AND DOWNSPOUTS TO BE APPROPRIATELY SIZED BASED ON RAINFALL
RECORDS AND CALCULATIONS FOR EASTERN TENNESSEE REGION. CONFIRM WITH ROOF
MANUFACTURER.
6. PROVIDE FLASHING AT VALLEYS, ALL ROOF/WALL INTERSECTIONS, ROOF PENETRATIONS,
AND AS SPECIFIED BY ROOFING MANUFACTURER.
7. COORDINATE ALL DOWNSPOUT LOCATIONS W/ WINDOWS AND DOORS. ALL
DOWNSPOUTS TO RUN DOWN WALLS OR COLUMNS
8. VERIFY EXACT NUMBER & LOCATION OF ALL VENT PIPES, ROOF PENETRATIONS, ETC IN
FIELD. PROVIDE FLASHING AROUND ALL ROOF PENETRATIONS
9. PROVIDE ALL ROOF ACCESSORIES INCLUDING FLASHING BOOTS, COUNTER FLASHING,
DRIP EDGES, COPING, AND ALL OTHER ACCESSORIES REQUIRED TO PROVIDE A WATER
TIGHT ROOF SYSTEM THAT WILL MEET THE ROOF WARRANTY REQUIREMENTS.
10. FOR ROOF PITCHES 4:12 OR GREATER, INSTALL WEATHER BARRIER AS UNDERLAYMENT
OVER ROOF AND OVER ICE AND WATER SHIELD TO EXTEND 18" FROM ALL EDGES. ICE &
WATERSHIELD TO BE AT ALL VALLEYS 36" WIDE. FOR ROOF PITCHES LESS THAN 4:12,
INSTALL ICE AND WATER SHIELD AS UNDERLAYMENT CONTINUOUSLY FROM RIDGE TO
EAVE AND FROM EDGE TO EDGE.
11. PROVIDE BOX GUTTERS AND RECTANGULAR DOWNSPOUTS AT SHOWN LOCATION.
GUTTERS TO BE SUPPORTED AT 3'-0" O.C. PROVIDE DOWNSPOUT STRAPS AT 5'-0" O.C.
VERTICAL FOR EACH DOWNSPOUT.
ROOF PLAN NOTES
SEE SCH.
F
*T=TEMPERED GLAZING
S E E S
C H
2" SEE SCH. 2"
F1
S E E S
C H
4' - 0"
A
*F=FROSTED FILM ON GLAZING
*F
"1
"2
2" 3' - 8" 2"
DATE:
PROJECT NO:
A N e w
R e st ro o m
B u ild in g f o r:
M c
F e e R o a d F a rr a g u t, T
N
M c
F E E P
A R
K
11/24/2025
253128
A1.1
PLANS, DOOR &
WINDOW
ELEVATIONS &
SCHEDULES
11/24/2025
1/2" = 1'-0"A1.1
1 FLOOR PLAN
1/4" = 1'-0"A1.1
2 REFLECTED CEILING PLAN
1/4" = 1'-0"A1.1
3 ROOF PLAN
1/4" = 1'-0"A1.1
4 DOOR AND FRAME ELEVATIONS
DOOR AND FRAME SCHEDULE
NO.
DOOR FRAME
HARDWARE NOTES
SIZE
THK MTL ELEV MTL ELEVW H
101 3' - 0" 7' - 0" 2" HM F INSUL. HM F1 1 PRIVACY HARDWARE
102 3' - 0" 7' - 0" 2" HM F INSUL. HM F1 2 STOREROOM HARDWARE
103 3' - 0" 7' - 0" 2" HM F INSUL. HM F1 1 PRIVACY HARDWARE
1/4" = 1'-0"A1.1
5 GLAZING ELEVATIONS
REVISIONS
REV # Description Date
1 Revision 1-AHJ Comments
1/5/2025
HARDWARE
1). Manufacturers Used for Basis of Design:
1. Butt Hinges - Hager (HAG)
2. Grade 2 Cylindrical Locks - Accentra 5300LN Series (ACC)
3. Grade 2 Classroom Deadbolts - Accentra D200 Series (ACC)
4. Privacy Lever with Indicator - Accentra YPL Series (ACC)
5. Grade 1 Closers - LCN 4110 Series (LCN)
6. Kick Plates - Hager (HAG)
7. Latch Guards - Don-Jo (DON)
8. Weatherstripping, Thresholds, & Sweeps - National Guard Products (NGP)
2). Approved Manufacturer Substitutions:
1. Butt Hinges - Best, Ives, Mckinney, PBB
2. Grade 2 Cylindrical Locks - N/A
3. Grade 2 Classroom Deadbolts - N/A
4. Privacy Lever with Indicator - N/A
5. Grade 1 Closers - N/A
6. Kick Plates - Burns, Ives, Rockwood
7. Latch Guards - Burns, Hager, Ives, Rockwood
8. Weatherstripping, Thresholds, & Sweeps - Pemko, Zero International
3). Provide 5-Knuckle Ball-Bearing hinges at each door. Provide non-removable pin hinges on out-swinging exterior doors.
4). All locksets, cylinders, and cylinder cores to be provided in the owner’s existing keyway.
5). The finish of hinges, locksets, and miscellaneous hardware shall be satin chrome/stainless steel or equivalent for all doors. Weatherstripping shall be anodized aluminum.
6). Provide door closers to comply with the state handicap code with regard to opening force.
7). Install door closers on the interior side of doors away from public areas.
8). Provide hardware sets as follows:
Set#: 1 Door(s): 101, 103
Each To Have:
Quantity Item Model Number Manufacturer Finish
3 Butt Hinge BB1191-4.5x4.5 NRP HAG 626
1 Privacy Lever w/Ind. YPL02-AU ACC 626
1 Classroom Deadbolt D262 ACC 626
1 Door Closer 4111-SCUSH LCN 689
1 Kick Plate 190S-8”x2” LDW HAG 630
1 Weatherstrip 127NA NGP - - -
1 Door Sweep 200NA NGP - - -
1 Threshold 425 NGP MILL
Set#: 2 Door(s): 102
Each To Have:
Quantity Item Model Number Manufacturer Finish
3 Butt Hinge BB1191-4.5x4.5 NRP HAG 626
1 Storeroom Lever AU5305LN ACC 626
1 Door Closer 4111-SCUSH LCN 689
1 Kick Plate 190S-8”x2” LDW HAG 630
1 Latch Guard BLP-107 DON 630
1 Weatherstrip 127NA NGP - - -
1 Door Sweep 200NA NGP - - -
1 Threshold 425 NGP MILL
-R- FIRE SAFETY SIGNAGE DTLS
1. COORDINATE WITH APPLICABLE DIMENSIONS AND DETAILS ON OTHER SHEETS
2. ICJ = INSIDE CONTROL JOINT
3. CONTROL JOINTS TO BE ALIGNED WITH EDGE OF ADJACENT WINDOW OR DOOR FRAME
AS SHOWN ON ELEVATIONS. LOCATE CONTROL JOINTS MAXIMUM 25'-0" O.C. WHERE
NOT SHOWN. COORDINATE LOCATIONS WITH ARCHITECT
4. PROVIDE CONTROL JOINTS MINIMUM 2'-0" OFF EDGE OF OUTSIDE CORNER IF NOT
SHOWN ALIGNED WITH FRAME. ALIGN DOWNSPOUT TO COVER CONTROL JOINTS
WHERE APPLICABLE
5. VERTICAL CONTROL JOINT FILLER TO MATCH MASONRY COLOR. HORIZONTAL
CONTROL JOINT FILLER TO MATCH GROUT COLOR
6. CJ = CONTROL JOINT
7. DIMENSIONS ARE TO FACE OF MASONRY, COMPOSITE METAL PANEL, CURTAIN WALL OR
EDGE OF OPENING UNLESS NOTED OTHERWISE
ELEVATION NOTES
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
4' - 0"
8" SPLIT FACE CMU W/ LOXON 40%
SILANE WATER REPELLANT SEALER
(CLEAR), TYP.
PRE�FI�ISHED A
U�� B�X
GUTTERI�G & 4" SQ� D�W�SP�UT
COLUMN, SEE STRUCTURAL
A4.1
8"
STA�DI�G SEA� �ETA
R��FI�G
ALUM. STOREFRONT W/ FROSTED
FILM ON GLAZING
CONTROL JOINT, CONFIRM W/
STRUCT.
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
1X6 CEDAR NICKEL GAP T&G
SIDING, NEAR CLEAR (SEALED
PRIOR TO INSTALLATION)
A4.1
8" SPLIT FACE CMU W/ LOXON
40% SILANE WATER REPELLANT
SEALER (CLEAR), TYP.
PRE-FINISHED ALUM.
GUTTERING & DOWNSPOUTS,
TYP.
4" / 1 '-0"
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
A .F
.F
O .C
103102101
A4.1
4" / 1 '-0"
ACCESSIBLE TLT SIGNAGE
STAFF ONLY SIGNAGE
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
4' - 0"
A4.1
STOREFRONT WINDOW W/
TRANSLUCENT FILM, PROVIDE SILL
PAN FLASHING AT SILL SLOPED TO
EXTERIOR FACE OF CMU
A
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
RESTROOM
D
C
F
B
A
B
B
PNT-2, TYP.
PNT-1, TYP.
EPB-1 6" BASE
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
MECHANICAL
102 PNT-2, TYP.
PNT-1, TYP.
MOP SINK, SEE
PLUMBING
ELECTRICAL PANELWOOD WALL SHELF,
PAINTED W/HEAVY-DUTY
STEEL SHELF BRACKETS -
CONFIRM QTY.
W/OWNER
J
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
RESTROOM
H
B
A E
B
B
PNT-2, TYP.
PNT-1, TYP.
EPB-1 6" BASE
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
A
RESTROOM
H
PNT-2, TYP.
PNT-1, TYP.
EPB-1 6" BASE
G
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
PNT-3
PNT-2, TYP.
PNT-1, TYP.
RESTROOM
D
F
C
EPB-1 6" BASE
G
H
ITEM # DESCRIPTION
TOILET LEGEND
TOILET TISSUE DISPENSER. OWNER
FURNISHED - N.I.C.
GRAB BARS. BOBRICK, SEE G0.2
WALL MIRROR. BOBRICK WELDED FRAME
MIRROR, SATIN FINISH B-290 1830; 18"X30"
ELECTRIC HAND DRYER. XLERATOR, XL-SB,
BRUSHED SS COVER
SURFACE-MOUNTED SANITARY NAPKIN
DISPOSAL. BOBRICK MODEL NO.: B-254,
FINISH: SATIN.
SOAP DISPENSER. OWNER FURNISHED -
N.I.C.
SURFACE MOUNTED HAT & COAT HOOK,
SATIN FINISH, BOBRICK B-6827
BABY CHANGER. KOALA KARE;
HORIZONTAL SURFACE MOUNTED
STAINLESS STEEL; KB110-SSWM
A
B
C
D
E
F
G
H
SURFACE MOUNTED MOP & BROOM
HOLDER, SATIN FINISH, BOBRICK B-223x24J
DATE:
PROJECT NO:
A N e w
R e st ro o m
B u ild in g f o r:
M c
F e e R o a d F a rr a g u t, T
N
M c
F E E P
A R
K
11/24/2025
253128
A3.1
BUILDING
ELEVATIONS &
INTERIOR
ELEVATIONS
11/24/2025
1/4" = 1'-0"A3.1
1 EAST BUILDING ELEVATION
1/4" = 1'-0"A3.1
2 NORTH BUILDING ELEVATION
1/4" = 1'-0"A3.1
3 SOUTH BUILDING ELEVATION
1/4" = 1'-0"A3.1
4 WEST BUILDING ELEVATION
1/4" = 1'-0"A3.1
6 RESTROOM ELEV.
1/4" = 1'-0"A3.1
5 MECH RM. ELEV.
1/4" = 1'-0"A3.1
7 RESTROOM ELEV.
1/4" = 1'-0"A3.1
8 RESTROOM ELEV.
1/4" = 1'-0"A3.1
9 RESTROOM ELEV.
ROOM FINISH SCHEDULE
NO. ROOM NAME
FINISH
NOTESFLOOR BASE WALL CEILING
101 RESTROOM EXP-1 EPB-1 PNT-1 PNT-2
102 MECHANICAL CON-2 - PNT-1 PNT-2
103 RESTROOM EXP-1 EPB-1 PNT-1 PNT-2
104 ENTRY CON-1 - - CS-1
FINISH KEY
MATERIAL ABB. DESCRIPTION NOTES
BRUSHED CONCRETE CON-1 CONCRETE WITH BROOM FINISH TO MATCH ADJACENT
SIDEWALK FINISH
SEALED CONCRETE CON-2 SEALED CONCRETE WITH BRUSH FINISH
RESINOUS FLOORING RF-1 DURA-FLEX; DURA-CHIP; ARMOR TOP GLOS
RESINOUS WALL BASE RWB-1 DURA-FLEX; DURA-CHIP; ARMOR TOP GLOS; 6" H. INTEGRAL BASE
WALL PAINT - EPOXY PNT-1 EPOXY PAINT; COLOR: SHERWIN WILLIAMS, REPOSE
GRAY, SW 7015
PAINT RAW CONCRETE WITH
BLOCK FILLER PRIMER; COORD.
W/EPOXY TOP COAT REQ'MTS
CEILING PAINT PNT-2 SHERWIN WILLIAMS, SNOWBOUND, SW 7004; FINISH:
SATIN
PAINT RAW WOOD WITH PRIMER
PRIOR TO FINAL FINISH
DOOR & FRAME PAINT PNT-3 SHERWIN WILLIAMS; PORPOISE, SW 7047; FINISH:
SEMI-GLOSS
STRUCTURAL STEEL PAINT PNT-4 SHERWIN WILLIAMS; PORPOISE, SW 7047; FINISH:
SEMI-GLOSS
CEDAR SIDING SEALER CS-1 CEDAR, GRADE: NEAR CLEAR, MARINE GRADE
SEALER
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
A4.1
PRE-ENGINEERED
WOOD TRUSSES
STANDING SEAM METAL
ROOF, PAC-CLAD OR EQ.,
ON WEATHER BARRIER, ON
EXT. GRADE SHEATHING
PRE-FINISHED ALUM. GUTTER &
DOWNSPOUT
8" SPLIT FACE CMU W/ LOXON
40% SILANE WATER REPELLANT
SEALER (CLEAR), TYP.
STOREFRONT WINDOW W/
TRANSLUCENT FILM, PROVIDE SILL
FLASHING AT SILL SLOPED TO
EXTERIOR FACE OF CMU
MOP SINK
BOND BEAM @ T.O. WALL &
WINDOW HEAD, SEE STRUCTURAL
A4.1
A4.1
R-38 MIN. BATT INSULATION
REINF. CONT. CONCRETE
FOOTING, SEE STRUCTURAL
A E
B
B
B
EA
B
B
B
HH
ELECTRICAL PANEL
R-10 MIN. RIGID PERIMETER
FOUNDATION INSUL, TYP.
CONT. PERF. FOUNDATION
DRAIN, INSTALL PER 2018 IBC,
SECTION 1805.4.2
CEDAR SHIPLAP T&G SOFFIT,
SEALED
1X4 CEDAR TRIM, SEALED
CONT. FLASHING & DRIP EDGE
1X6 CEDAR FASCIA, SEALED ON
P.T. 2X4 SUB-FASCIA, TYP.
GROUND LEVEL
0"
T.O. MASONRY
8' - 8"
A4.1
A
11 1/2"
SPLIT FACE 8" CMU
BLOCK WALL
STANDING SEAM METAL ROOFING,
PAC-CLAD OR EQ., ON WEATHER
BARRIER ON EXT. GRADE SHEATHING
A4.1
1X6 CEDAR FASCIA ON P.T. 2X4
SUB-FASCIA, TYP.
CEDAR SHIPLAP T&G SIDING,
SEALED, TYP.
8x8 STEEL BEAM
8x8 STEEL COLUMN
PRE-ENGINEERED WOOD
TRUSS
CEDAR TRIM BOARD
A4.1
A4.1
R-38 MIN. BATT INSULATION
CONTINUOUS CONCRETE
FOOTING, SEE STRUCTURAL
A4.1
Sim
A4.1
Sim
H
G
HM DOOR, SEE
SCHEDULE
PRE-FINISHED ALUM. DRIP EDGE
@ RAKE EDGE, TO MATCH
ROOFING FINISH
CONT. PERF. FOUNDATION
DRAIN, INSTALL PER 2018 IBC,
SECTION 1805.4.2
1X6 CEDAR SHIPLAP T&G SOFFIT,
SEALED
T.O. MASONRY
8' - 8"
SELF-ADHERED FLEXIBLE FLASHING
SPLIT FACE 8" CMU
BLOCK WALL
ANCHOR BOLT
METAL FLASHING W/ DRIP EDGE
2x4 FRAMING W/ R-20 BATT
INSULATION @ 16" O.C. MAX
5/8" EXTERIOR GRADE
PLYWOOD SHEATHING
WD BLOCKING AS
REQ'D
GRADE A PLYWOOD CLG,
PAINTED
1x TRIM & BATTENS, PAINTED
DOUBLE 2x6 P.T. TOP
PLATE
P.E. ROOF TRUSS, SEE
STRUCTURAL
1X6 CEDAR NICKEL GAP, T&G
SIDING, SEALED, EXTENDED 2"
PAST CMU
SPLIT FACE BOND
BEAM, SEE STRUCTURAL
CAU�� A�D BAC�ER R�D
SHI� AS REQUIRED
A�U�I�U� ST�REFR��T� SEE
G�A�I�G E�EVATI��S
SP�IT FACE 8" C�U B��D
BEA�� SEE STRUCTURA�
SEA�A�T A�D BAC�ER R�D
CAU�� A�D BAC�ER R�D
SHI� AS REQUIRED
A�U�I�U� ST�REFR��T� SEE
G�A�I�G E�EVATI��S
SP�IT FACE 8" C�U B��C�
WA��
SEA�A�T A�D BAC�ER R�D
C�U SI�� B��C�
PA� F�ASHI�G
GROUND LEVEL
0"
HM DOOR, SEE SCHEDULE
1/2" EXPANSION JOINT
4" CONCRETE SLAB OVER MIN.
4" CLEAN CRUSHED GRAVEL
8" CMU WALL, GROUTED
SOLID BELOW GRADE, SEE
STRUCTURAL
H.M. FRAME - FILL W/ GROUT
SPLIT FACE 8" CMU BOND
BEAM, SEE STRUCTURAL
CAULK AND BACKER RODSEALANT AND BACKER ROD
DOOR AS SCHEDULED
DATE:
PROJECT NO:
A N e w
R e st ro o m
B u ild in g f o r:
M c
F e e R o a d F a rr a g u t, T
N
M c
F E E P
A R
K
11/24/2025
253128
A4.1
BUILDING
SECTIONS &
DETAILS
11/24/2025
1/2" = 1'-0"A4.1
1 BUILDING SECTION
1/2" = 1'-0"A4.1
2 BUILDING SECTION
1 1/2" = 1'-0"A4.1
3 DETAIL @ TOP OF MASONRY
1 1/2" = 1'-0"A4.1
4 STOREFRONT HEAD/ JAMB DETAIL
1 1/2" = 1'-0"A4.1
5 STOREFRONT SILL DETAIL
1 1/2" = 1'-0"A4.1
6 HM DOOR THRESHOLD DETAIL
1 1/2" = 1'-0"A4.1
7 HM DOOR HEAD/JAMB DETAIL
ALL CONSTRUCTION SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE. REFERENCE TO OTHER STANDARD SPECIFICATIONS OR CODES SHALL MEAN THE LATEST STANDARD OR CODE ADOPTED AND PUBLISHED
UNLESS SPECIFIED OTHERWISE.
DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR TO THOSE SHOWN.
VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS BEFORE STARTING WORK. NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCY. NOTIFY THE STRUCTURAL ENGINEER IN WRITING OF CONDITIONS ENCOUNTERED IN THE FIELD CONTRADICTORY TO THOSE SHOWN ON THE STRUCTURAL CONTRACT DOCUMENTS.
THE STRUCTURE IS DESIGNED FOR A COMPLETED CONDITION ONLY, AND THEREFORE REQUIRE TEMPORARY SUPPORT BRACING DURING CONSTRUCTION. THE STRUCTURE SHALL BE CONSIDERED STABLE WHEN : ALL THE FRAMING HAS BEEN ERECTED AND CONNECTED AS SHOWN ON THE DESIGN AND SHOP FABRICATION DRAWINGS, SLAB, FLOOR, AND ROOF DIAPHRAGMS ARE COMPLETELY ATTACHED AND CURED AND THE FOOTINGS HAVE BEEN COMPLETELY BACKFILLED. THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY
SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
FOR DIMENSIONS NOT SHOWN, SEE ARCHITECTURAL DRAWINGS.
REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE STRUCTURAL ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP DRAWINGS BEFORE SUBMITTAL TO THE STRUCTURAL ENGINEER. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, ASSEMBLY REQUIREMENTS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS ALSO RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES AND SAFETY OF CONSTRUCTION.
CONTRACTOR TO REFER TO DRAWINGS OF OTHER TRADES AND VENDOR DRAWINGS FOR EMBEDDED ITEMS AND
RECESSES NOT SHOWN ON THE STRUCTURAL DRAWINGS.
CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL MECHANICAL AND ELECTRICAL OPENINGS AND EQUIPMENT PADS WITH THE MECHANICAL AND ELECTRICAL EQUIPMENT DETAILS AND APPROVED SHOP DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL OPENINGS AND
SLEEVES FOR PROPER DISTRIBUTION FOR ALL UTILITY LINES THROUGHOUT THE BUILDING.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN, INSTALLATION AND FINAL REMOVAL/CLEARANCE OF
ANY REQUIRED SHORING OR BRACING OF STRUCTURES.
1.01
1.02
1.03
1.04
1.05
1.06
1.07
1.08
1.09
GENERAL NOTES :
DESIGN LOADS: 2018 IBC (ASCE 7-16)
DEAD LOADS:
ROOF:......................................................................................................................................SELF WEIGHT OF MATERIAL AS SHOWN FLOOR.....................................................................................................................................SELF WEIGHT OF MATERIAL AS SHOWN
LIVE LOADS:
ROOF:......................................................................................................................................20 psf FLOOR SLAB:.........................................................................................................................100 psf
WIND LOADS:
ULTIMATE DESIGN WIND SPEED:.......................................................................................104 MPH EXPOSURE CATEGORY:.......................................................................................................C OCCUPANCY CATEGORY:....................................................................................................II IMPORTANCE FACTOR:........................................................................................................1.0 (MAIN WIND FORCE RESISTING SYSTEM)
1.15 (COMPONENTS AND CLADDING)
ENCLOSURE CLASSIFICATION:..........................................................................................ENCLOSED INTERNAL PRESSURE COEFFICIENT:................................................................................+/-0.18
WALL COMPONENTS AND CLADDING:..............................................................................25 sf +/- 38 psf 50 sf +/- 33 psf 75 sf +/- 30 psf 100 sf +/- 28 psf
SEISMIC LOADS
MAPPED SPECTRAL RESPONSE ACCELERATION:.........................................................SS = 65.4% S1 = 13.8% OCCUPANCY CATEGORY:....................................................................................................II SEISMIC IMPORTANCE FACTOR:........................................................................................1.0 SITE CLASS:...........................................................................................................................D SPECTRAL RESPONSE COEFFICIENT:...............................................................................SDS = 0.557
SD1 = 0.214
SEISMIC DESIGN CATEGORY:.............................................................................................D BASIC SEISMIC FORCE RESISTING SYSTEM:...................................................................ORDINARY REINFORCED MASONRY SHEAR WALLS RESPONSE MODIFICATION FACTOR, R:...........................................................................2.0 ANALYSIS PROCEDURE USED:..........................................................................................EQUIVALENT LATERAL FORCE SEISMIC RESPONSE COEFFICIENTS, Cs:.........................................................................0.279 DESIGN BASE SHEAR, V:....................................................................................................0.279W
SNOW LOADS
GROUND SNOW LOAD, Pg:..................................................................................................10 psf FLAT ROOF SNOW LOAD, Pf:..............................................................................................7 psf SNOW EXPOSURE FACTOR, Ce:.........................................................................................1.0 SNOW LOAD IMPORTANCE FACTOR, I:.............................................................................1.0 THERMAL FACTOR, Ct:........................................................................................................1.0 RAIN ON SNOW SURCHARGE:............................................................................................5 psf (BALANCED LOAD)
ALLOWABLE SOIL BEARING PRESSURE:...........................................................................................2,000 psf (DESIGN BASIS)
FOUNDATION NOTES :
OWNER OR CONTRACTOR'S GEOTECHNICAL ENGINEER SHALL VERIFY CONDITION AND/OR ADEQUACY OF ALL SUBGRADE, FILLS, AND BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTING, SLABS, WALLS, FILLS, BACKFILLS, ETC. ALL FOOTINGS SHALL REST EITHER ON UNDISTURBED SOIL OR NEWLY PLACED STRUCTURAL FILL. OWNER OR CONTRACTOR'S GEOTECHNICAL ENGINEER SHALL VERIFY ALLOWABLE SOIL BEARING CAPACITY PREPARATION REQUIREMENTS INCLUDING SUBGRADE IMPROVEMENT AND STRUCTURAL FILL PLACEMENT REQUIREMENTS. A MANUALLY OPERATED VIBRATOR SLED OR TAMPER SHOULD BE USED TO DENSIFY ANY SOILS
IN THE BOTTOM OF THE FOOTING TRENCHES LOOSENED DURING THE EXCAVATION PROCESS.
SIDES OF THE FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. FOUNDATIONS POURED AGAINST THE EARTH REQUIRE THE FOLLOWING PRECAUTIONS : SLOPE SIDES OF EXCAVATIONS AS APPROVED BY THE GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING BEFORE AND DURING CONCRETE
PLACEMENT.
CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY PROTECTING ALL EXCAVATION SLOPES.
WHERE FOOTING STEPS ARE NECESSARY THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO TWO
HORIZONTAL.
2.01
2.02
2.03
2.04
SPLICE, TYP.
CLASS 'B' 2 x "H" (MINIMUM)
(2 '-0
M
A X
"H
TYPICAL FOOTING STEP DETAIL
NOT TO SCALE
"Z" BAR SAME SIZE &
NUMBER AS CONTINUOUS REINF.
CONTINUOUS FOOTING. SEE PLAN
FOR SIZE AND REINFORCING
TYPICAL
3" CLEAR
T Y
P
IC
A L
3" C
L E
A R
THE BOTTOM OF FOOTINGS SHALL BEAR BELOW THE FROST DEPTH AS SPECIFIED IN THE GEOTECHNICAL
REPORT OR BY THE LOCAL MUNICIPALITY.
FOOTINGS MUST BE BACKFILLED BEFORE THE STRUCTURE IS CONSIDERED STABLE. CONCRETE SLAB SHALL REACH 28 DAY COMPRESSIVE STRENGTH BEFORE THE STRUCTURE IS CONSIDERED STABLE.
COORDINATE FOOTING STEPS WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS.
SOIL SUPPORTED SLABS ON GRADE ARE DESIGNED TO BEAR ON A SUBGRADE WITH A MINIMUM MODULUS OF SUBGRADE REACTION OF 150 PCI. WHERE POSSIBLE. SEE GEOTECHNICAL REPORT FOR AREAS WHERE
MINIMUM MODULUS OF SUBGRADE REACTION WILL DIFFER.
WHERE FOUNDATION EXCAVATIONS MUST REMAIN OPEN AND ARE SUBJECT TO RAINFALL, THE EXCAVATIONS SHALL BE UNDERCUT AND A 3" THICK MUD MAT OF 2,000 PSI CONCRETE SHALL BE PLACED IN THE BOTTOM TO
PROTECT THE BEARING SOILS.
2.05
2.06
2.07
2.08
2.09
WOOD TRUSS NOTES:
WOOD TRUSSES SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE'S TPI 1-2014 "NATIONAL DESIGN STANDARDS FOR METAL-PLATE-CONNECTED WOOD TRUSS CONSTRUCTION" AND
THE 2018 INTERNATIONAL BUILDING CODE..
WOOD TRUSSES TO BE DESIGNED BY A REGISTERED ENGINEER IN THE STATE OF TENNESSEE.
WOOD TRUSS DESIGNER TO COORDINATE LAYOUT AND SPACING WITH MECHANICAL, ELECTRICAL, AND PLUMBING.
DESIGNER TO PROVIDE MAXIMUM ALLOWABLE SHIFTS BASED ON MECHANICAL, ELECTRICAL, AND PLUMBING LAYOUT.
ALL RECOMMENDATIONS FOR BRACING, QUALITY CONTROL, AND DESIGN OF THE TRUSSES SHALL BE PER THE TRUSS
PLATE INSTITUTE SPECIFICATIONS.
PROVIDE SHOP DRAWINGS SHOWING STRESS DIAGRAMS STAMPED WITH SEAL OF DESIGNING ENGINEER. THE
FOLLOWING ITEMS TO BE INCLUDED WITH SHOP DRAWINGS:
A. LAYOUT PLAN INDICATING LOCATIONS AND TRUSS TYPE.
B. TRUSS DETAILS AND TRUSS TO TRUSS CONNECTIONS.
C. BRACING REQUIREMENTS.
D. ANY OTHER INFORMATION REQUIRED TO COMPLETE TRUSS PORTION OF CONTRACT.
PROVIDE SPECIAL DESIGNED TRUSSES FOR CORNERS, GIRDERS, HEADERS, ETC.
ROOF TRUSSES TO BE DESIGNED FOR FOLLOWING LOADS (UNLESS NOTED OTHERWISE):
A. LIVE LOAD TOP CHORD............................................................................................................................................20 psf B. DEAD LOAD TOP CHORD.........................................................................................................................................10 psf C. DEAD LOAD BOTTOM CHORD.................................................................................................................................10 psf
D. WIND LOADS, SEISMIC LOADS, AND SNOW LOADS PER DESIGN LOADS IN GENERAL NOTES
ALL LUMBER TO BE A MINIMUM SIZE OF 2 X 4 #2 SOUTHERN PINE, KILN DRIED, FOR TOP AND BOTTOM CHORDS AND
#3 SOUTHERN PINE, KILN DRIED, FOR WEBS.
ALTHOUGH WEB LAYOUT MAY BE SHOWN ON PLANS, IT IS RESPONSIBILITY OF TRUSS DESIGNER TO MODIFY AS
REQUIRED FOR DESIGN PURPOSES.
TRUSSES TO BE CONNECTED TO NAILERS WITH SIMPSON STRONG TIE OR "H2.5A" TRUSS CONNECTORS, OR EQUIVALENT, WITH A MINIMUM G185 GALVANIZED COATING AT EACH BEARING LOCATION, UNLESS NOTED OTHERWISE.
MAXIMUM SPACING OF ROOF TRUSSES TO BE 24" ON CENTER, U.N.O.
THE VERTICALS OF GABLE END TRUSSES SHALL BE AT 16" O.C. AND DESIGNED FOR OUT-OF-PLANE WIND LOADS PER
DESIGN LOADS IN GENERAL NOTES.
CONTRACTOR AND SUPPLIER TO PROVIDE ALL LABOR AND MATERIALS TO COMPLETE TRUSS PORTION OF PROJECT.
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
AS A MINIMUM, PERMANENT 2X4 DIAGONAL BRACING SHALL BE NAILED TO THE TOP SIDE OF THE ROOF TRUSS BOTTOM CHORDS AND BOTTOM SIDE OF THE TRUSS TOP CHORDS AT EACH END OF THE BUILDING AND AT 20 FOOT INTERVALS.
ATTACH BRACING TO CHORDS USING (2) 16d x 3 1/2" COMMON NAILS.
WOOD TRUSSES SHALL NOT BE CUT, NOTCHED, OR BORED.
3.01
3.02
3.03
3.04
3.05
3.06
3.07
3.08
3.09
3.10
3.11
3.12
3.13
3.14
3.15
3.16
STRUCTURAL STEEL NOTES :
STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED ACCORDING TO AISC CODE OF STANDARD PRACTICE, LATEST EDITION AND THE REQUIREMENTS OF OSHA 29 CFR PART 1926, SUB-PART R, SAFETY STANDARDS
FOR STEEL ERECTION.
SUBMIT SHOP DRAWINGS PREPARED IN ACCORDANCE WITH AISC MANUAL, DETAILING FOR STEEL CONSTRUCTION, LATEST EDITION. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED, REVIEWED AND APPROVED.
THE USE OF STRUCTURAL DRAWINGS FOR SHOP DRAWING PURPOSES SHALL NOT BE PERMITTED.
STEEL SHAPES AND MATERIALS :
STRUCTURAL STEEL WIDE FLANGE SHAPES
PLATES, ANGLES AND CHANNELS
STRUCTURAL SQUARE TUBING
STRUCTURAL ROUND TUBING
STEEL PIPE
BOLTS
STEEL FABRICATOR SHALL SUPPLY ANCHOR BOLT LOCATION DRAWINGS. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GR. 36 AND SHALL HAVE A MINIMUM DIAMETER OF 3/4", UNLESS NOTED OTHERWISE. ANCHOR BOLTS SHALL BE STRAIGHT WITH AN EMBEDDED END NUT AND WASHER, TACK WELD WASHER TO END NUT, PROVIDE 8" EMBEDMENT TO TOP OF EMBEDDED WASHER, UNLESS NOTED OTHERWISE. ANCHOR BOLT THREADS SHALL PROJECT 6" ABOVE TOP OF CONCRETE TO RECEIVE DOUBLE NUT AND WASHER FOR LEVELING. PROVIDE PROTECTION COVER FOR EXPOSED THREADS AND NUTS ABOVE THE BASE PLATE. ANCHOR BOLTS SHALL BE SET WITH TEMPLATES, HOLE PATTERN OF TEMPLATE SHALL MATCH BASE PLATE, AND THE TEMPLATE MUST BE SECURELY DOUBLE NUTTED TO ANCHOR BOLTS DURING CONCRETE INSTALLATION. PROVIDE 1 1/2" OF NON-SHRINK GROUT BELOW
BASE PLATE, UNLESS NOTED OTHERWISE. BE CAREFUL OF WELDING ON STRESS SIDE OF NUT.
USE PRE-QUALIFIED WELDED JOINTS AS PER AISC, AND AWS D1.1, STRUCTURAL WELDING CODE. USE ONLY CERTIFIED WELDERS, ALL ELECTRODES SHALL CONFORM TO AWS A5, GRADE E70XX. BARE ELECTRODE AND GRANULAR FLUX SHALL CONFORM TO AWS A5, F70 AWS FLUX CLASSIFICATION. PROVIDE AWS WELDER CERTIFICATION RECORD OF ALL WELDERS. MINIMUM WELD SIZE TO BE 3/16" FILLET WELD, UNLESS
NOTED OTHERWISE.
CUTS, BOLTS, COPING, ETC. REQUIRED FOR WORK OF OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS…