Marion VA_Renovate 3B_Bid Documents_Drawings_V2 of 4_09-20-2024 26 pages.pdf

PDF 10 MB Posted

Attached to
Z2DA--657A5-23-110, Renovate 3B for Patient Privacy and Intensive Care Unit, (VA-25-00018450)
Solicitation number
36C25525R0015
Issued by

About this file

This is a set of 26 architectural drawings for renovating Patient Ward 3B at the Marion VA Medical Center in Marion, IL to create patient privacy and intensive care spaces. The drawings include detailed floor plans, reflected ceiling plans, enlarged room plans, architectural details, schedules and assemblies for the renovation project. Key areas being renovated include ICU patient rooms, staff amenities, visitor spaces, and medical support areas.

The drawings provide comprehensive construction details including wall types, door schedules, window types, ceiling assemblies, and floor slopes/drains. Specific features include sliding doors with break-out panels for patient rooms, specialized medical equipment mounting requirements, and infection control considerations in the design of spaces like the HAC room and soiled utility areas. The plans show integration of medical gas systems, patient lifts, and nurse call systems. Architectural finishes and materials are specified throughout, with particular attention to durability and infection control in clinical spaces. The drawings are marked as "Final Bid Documents" dated September 20, 2024 and were prepared by Stone/HFG Architecture.

View the file

Other files

File Type Posted
36C25525R0015 0006.docx DOCX document
S02 36C25525R0015 657A5-23-110 R3.docx DOCX document
Renovate 3B Hazardous Material Report.pdf PDF
36C25525R0015 0005.docx DOCX document
Sheet AI100 Color Schedule Key.pdf PDF
36C25525R0015 0004.docx DOCX document
36C25525R0015 0003.docx DOCX document
S04 Pre-Bid Site Visit Attendance.pdf PDF
36C25525R0015 0002.docx DOCX document
Requirements for Identification and Replacement of A307 Bolts Memo_Signed.pdf PDF
Marion VA_Renovate 3B_Bid Documents_Drawings_V1 of 4_09-20-2024 28 pages - Copy.pdf PDF
Marion VA_Renovate 3B_Bid Documents_Drawings_V4 of 4_09-20-2024 41 pages - Copy.pdf PDF
Marion VA_Renovate 3B_Bid Documents_Drawings_V2 of 4_09-20-2024 26 pages - Copy.pdf PDF
36C25525R0015 0001.docx DOCX document
S02 36C25525R0015 657A5-23-110.docx DOCX document
Marion VA_Renovate 3B_Bid Documents_Drawings_V3 of 4_09-20-2024 30 pages - Copy.pdf PDF
Marion VA_Renovate 3B_Bid Documents_Specifications_09-20-2024 1723 pages rev1 - Copy.pdf PDF
Marion VA_Renovate 3B_Bid Documents_Drawings_V3 of 4_09-20-2024 30 pages.pdf PDF
36C25525R0015.docx DOCX document
Marion VA_Renovate 3B_Bid Documents_Drawings_V1 of 4_09-20-2024 28 pages.pdf PDF
Marion VA_Renovate 3B_Bid Documents_Specifications_09-20-2024 1723 pages rev1.pdf PDF
Marion VA_Renovate 3B_Bid Documents_Drawings_V4 of 4_09-20-2024 41 pages.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE

PROCEEDING WITH THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. FREE-STANDING FURNITURE IS PROVIDED AND INSTALLED BY OTHERS.

D. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

E. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.

F. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.

G. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.

H. PROVIDE BACKING FOR ALL TOILET ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED TO

BUILDING WALLS.

I. INSTALL BLOCKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING,

MARKERBOARDS, WALL MOUNTED MONITORS/TVS, COUNTERTOP SUPPORTS, ETC.

J. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD.

K. PROVIDE CONTROL JOINTS IN DRYWALL EVERY 30'-0".

L. ALL DIMENSIONS ARE TO OUTSIDE OF WALL FRAMING.

M. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

N. SEE SHEET AE601, ARCHITECTURAL SCHEDULES & ASSEMBLIES, FOR MORE INFORMATION

REGARDING DOORS, WINDOWS, AND WALL TYPES.

O. CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY EXISTING STRUCTURAL MEMBERS WHICH MAY

CONFLICT WITH THE DESIGNED WALL LAYOUT AND/OR DESIGNED PLUMBING LOCATIONS BEFORE ANY

WALLS ARE CONSTRUCTED.

P. CONTRACTOR TO NOTIFY ARCHITECT OF LOCATIONS WHERE PENETRATIONS IN THE FLOOR MAY INTERSECT AND/OR INTERFERE WITH THE INTERGITY OF EXISTING CONCRETE JOISTS. WHERE MEP SYSTEMS CANNOT BE EASILY REROUTED WITHIN ALREADY DESIGNED WALLS, CEILINGS, OR CHASES, THE A/E TEAM WILL REVISE AND REISSUE DRAWINGS SO AS TO AVOID CONFLICTS WITH THE EXISTING

JOISTS.

GENERAL PLAN NOTES

AA

RR

BB

DD

EE

GG

MM

KK

JJ

HH

FF

17151211109743

5 8 13 16

8'

-6

232'-6"

8'

-6

'-6

'-8

8' -6

'-8

'-8

'-0

'-1

0" 9'

-2

'-6

16'-0 1/2" 20'-5 1/2" 24'-9" 110'-0" 24'-9" 20'-5 1/2" 16'-0 1/2"

'-6

'-8

8' -6

'-8

'-8

'-0

'-1

0" 9'

-2

'-6

16'-0 1/2" 20'-5 1/2" 10'-7" 10'-9" 10'-9" 9'-11" 20'-0" 11'-8" 12'-2" 11'-8" 20'-0" 9'-11" 10'-9" 10'-9" 10'-7" 20'-5 1/2" 16'-0 1/2"

'-3

8'

-3

'-3

8'

-3

5' -0

5' -0

'-6

'-6

AE101

D5

AE102

D5

304B

STAFF TLT

STAFF

LOCKERS

LO

G

IS

T

IC

S

CLEAN

UTILITY

SOILED

UTILITY

CLEAN

LINEN

NOURISHMENT

EQUIPMENT

309A

WORKSTATIONS

ELEC

CONSULTATION

VISITOR

LOUNGE

VISITOR TLT

MEDICATION

304A

STAFF TLT

M U

LT

I-

P U

R P

O S

E

ICU

COMMAND

CENTER

HAC

NURSE

STATION

EQUIPMENT

ALCOVE

314A

ISO /

BARIATRIC

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

A N

T E

R O

O M

314B

ISO /

BARIATRIC

TLT

316A

PATIENT

TLT

317A

PATIENT

TLT

319A

PATIENT

TLT

322A

PATIENT

TLT

C301-01

CORRIDOR

S301-01

STAIR

P-2

ELEVATOR

OXYGEN

STORAGE

OFFICE

PHARMACY

LOGISTICS

NOURISHMENT

339A

ELEC

NURSE

MANAGER

S303-01

STAIR

PATIENT

BEDROOM

342A

BATH

PATIENT

BEDROOM

344A

BATH

343A

BATH

PATIENT

BEDROOM

NURSES

STATION

345B

CLEAN

LINEN

345C

SOILED

LINEN

345A

LOCKER

345D

STAFF RR

345E

STORAGE

345F

CORRIDOR

345G

JANITOR

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ANTE

ICU

BEDROOM

NURSES

STATION

C306-01

CORRIDOR

ICU

BEDROOM

STAFF

LOCKER

SOILED

UTILITY

ELEC

HAC

C305-01

CORRIDOR

C305-01

CORRIDOR

C307-01

CORRIDOR

PATIENT

BEDROOM

361A

BATH

PATIENT

BEDROOM

PATIENT

BEDROOM

362A

BATH

363A

BATH

C307-01

CORRIDOR

340A

CLOSET

NA

SEISMIC

TOWER A

NA

SEISMIC

TOWER B

NA

SHAFT B

NA

SHAFT A

S305-01

STAIR

P-7

ELEVATOR

S302-01

STAIR

P-1

ELEVATOR

S304-01

STAIR

NURSES

STATION

NURSES

STATION

CC

'-6

9'

-2

'-6

'-6

9'

-2

'-6

'-6

9'

-2

'-6

ELEC

STATION

ALCOVE

STATION

ALCOVE

ELEVATOR

LOBBY

C302-01

CORRIDOR

C

3-

C O

R R

ID

O

R

C

4-

C O

R R

ID

O

R

C

4-

C O

R R

ID

O

R

EQUIPMENT

ALCOVE

EQUIPMENT

ALCOVE

MED/SURG

PATIENT

ROOM

303A

PATIENT

TLT

STATION

ALCOVE

B6

AE301

B2

AE301

D6

AE301

1.10A

1.10A

C304-01

CORRIDOR

ADJACENT BUILDING

PATIENT

BEDROOM

TELEMETRY

RECEPTION

/ NURSES

STATION

301A

WORK AREA

364A

BATH

C301-01

CORRIDOR

LOCKER

C301-01

CORRIDOR

HAC

NO NEW ARCHITECTURAL CONSTRUCTION OR

DEMOLITION WEST OF DASHED LINE. WORK

WEST OF PROJECT AREA IS AT CEILINGS ONLY -

SEE DEMO RCPS AND MEP DRAWINGS.

8.10B 8.10B

8.10B

KEY PLAN - FLOOR - OVERALL

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

INDICATED THUS ON

CEILING PLANS

# RATING HEIGHT DESCRIPTION

A NON-RATED FULL-HEIGHT 5/8" GWB, 2 1/2" 20GA MTL STUD, 5/8" GWB

AA NON-RATED FULL-HEIGHT 5/8" GWB, 2 1/2" 20GA MTL STUD

AD NON-RATED TOW 6" AFC 5/8" GWB, 2 1/2" 20GA MTL STUD

B NON-RATED FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

B1 1-HOUR FIRE FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

B1S 1-HOUR F&S FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

BA NON-RATED FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD

BB SMOKE-COR FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

BC SMOKE-HAZ FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

C NON-RATED FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

C1 1-HOUR FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

C1S 1-HOUR F&S FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

CA NON-RATED FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD

CB SMOKE-COR FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

TYPICAL EXTERIOR FURRING

X NON-RATED FULL-HEIGHT 5/8" GWB, VB, 2 1/2" 20 GA MTL STUD, 1" RIGID INSULATION

XA NON-RATED FULL-HEIGHT VB, 2 1/2" 20 GA MTL STUD, 1" RIGID INSULATION

FINISH WALLS & COLUMN WRAPS

+A NON-RATED FULL-HEIGHT 5/8" GWB,

+BA NON-RATED FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BB SMOKE-COR FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BC SMOKE-HAZ FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BD NON-RATED TOW 6" AFC 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

MODIFIER (IF APPLICABLE)

FIRE RATING IN HOURS (IF APPLICABLE)

NOTE

1. FULL-HEIGHT = STRUCT BLW TO STRUCT ABV. SEE DETAILS FOR DEFLECTION GAPS & CHANNELS.

2. VB TO BE INSTALLED IN FURRING & FINISH WALLS AT EXT MASONRY OR CONCRETE WALLS. TIE INTO

EXISTING BARRIERS WHERE APPLICABLE.

3. SAFB TO NOT BE INSTALLED IN 2 1/2", OR SMALLER, STUD WALLS EXCEPT AT SHAFTS, STAIRWELLS, &

EXTERIOR WALLS.

WALL TYPES WALL TAG XX#

SEE SHEET

AE601 FOR

MORE INFO

SCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

(402) 991-5520

NATHAN BOWMAN (MECH & PUMB)

MAY ALEXANDER (ELEC)

BSE ENGINEERS

11320 WEST 79TH STREET

LENEXA, KS 66214

(913) 492-7400

KEVIN BOEHRINGER (STRUCT)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

2_ M ar io n V

A _R en ov at e

3B _k yl ek

9D U

H U

.rv t

9/

/2

:4 7:

A

M

AE100

ARCHITECTURAL FLOOR PLAN - 3RD LEVEL -

OVERALL

STONE / HFG ARCHITECTURE

600 EAST 7TH ST & 330 N. MEAD

SIOUX FALLS, SD 57103 & WICHITA, KS 67202

(605) 271-1144 & (316) 262-2500

BEAU FEY (ARCH) & WAYNE BONGARTZ (PM)

RENOVATE PATIENT WARD 3B

FOR PATIENT PRIVACY AND

INTENSIVE CARE

MARION IL

BLDG #001

WESLEY PINKS

09/20/2024 BF/WB/SS KK/AB/AW

SGA #231942

VA #657A5-23-110

FINAL BID DOCUMENTS

ARCH SHEET: 1 OF 26

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.10A EXISTING EXPANSION JOINT. FLOOR AND ROOF STRUCTURE ASSEMBLY TO REMAIN AS IS.

DAMAGED SEALANT AND/OR MORTAR EXPOSED BY CONSTRUCTION TO BE PATCHED OR

REPLACED. NEW CEILING AND/OR WALL ASSEMBLIES AT JOINT TO BE CONSTRUCTED

ACCORDING TO PROVIDED DETAILS.

8.10B REINSTALL WINDOW THAT WAS REMOVED FROM SPECIFIED LOCATION DURING DEMOLITION.

REPAIR ALL DAMAGE CAUSED BY CONSTRUCTION AT THE WINDOW OPENING. REPAIR AND/OR

REPLACE FLASHING, WEATHER PROOFING, INSULATION, AND EXTERIOR FINISH AS NEEDED.

1/8" = 1'-0" D5

FLOOR PLAN - 3RD LEVEL - OVERALL

NORTH

REVISION # DESCRIPTION DATE

PROCEEDING WITH THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. FREE-STANDING FURNITURE IS PROVIDED AND INSTALLED BY OTHERS.

D. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

E. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.

F. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.

G. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.

H. PROVIDE BACKING FOR ALL TOILET ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED TO

BUILDING WALLS.

I. INSTALL BLOCKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING,

MARKERBOARDS, WALL MOUNTED MONITORS/TVS, COUNTERTOP SUPPORTS, ETC.

J. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD.

K. PROVIDE CONTROL JOINTS IN DRYWALL EVERY 30'-0".

L. ALL DIMENSIONS ARE TO OUTSIDE OF WALL FRAMING.

M. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

N. SEE SHEET AE601, ARCHITECTURAL SCHEDULES & ASSEMBLIES, FOR MORE INFORMATION

REGARDING DOORS, WINDOWS, AND WALL TYPES.

O. CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY EXISTING STRUCTURAL MEMBERS WHICH MAY

CONFLICT WITH THE DESIGNED WALL LAYOUT AND/OR DESIGNED PLUMBING LOCATIONS BEFORE ANY

WALLS ARE CONSTRUCTED.

P. CONTRACTOR TO NOTIFY ARCHITECT OF LOCATIONS WHERE PENETRATIONS IN THE FLOOR MAY INTERSECT AND/OR INTERFERE WITH THE INTERGITY OF EXISTING CONCRETE JOISTS. WHERE MEP SYSTEMS CANNOT BE EASILY REROUTED WITHIN ALREADY DESIGNED WALLS, CEILINGS, OR CHASES, THE A/E TEAM WILL REVISE AND REISSUE DRAWINGS SO AS TO AVOID CONFLICTS WITH THE EXISTING

JOISTS.

GENERAL PLAN NOTES

AA

201918

BB

D

E

G

D

A

E

233 SF

EQUIPMENT

S304-01

STAIR

317 SF

NURSE

STATION

277 SF

ICU PATIENT

ROOM

285 SF

ICU PATIENT

ROOM

278 SF

ICU PATIENT

ROOM

54 SF

309A

WORKSTATIONS

98 SF

NOURISHMENT

95 SF

ANTE ROOM

106 SF

314B

ISO /

BARIATRIC

TLT

304 SF

314A

ISO /

BARIATRIC

ICU PATIENT

ROOM

49 SF

317A

PATIENT

TLT

52 SF

316A

PATIENT

TLT

17 SF

STATION

ALCOVE

17 SF

STATION

ALCOVE

CC

67 SF

ELEC

24 SF

EQUIPMENT

ALCOVE

314B

7A

6A

B2

AE311

D4

AE311

B5

AE311

D3

AE311

B5

AE312

B1

AE311

314A

W3

W3

10.40A

V F

Y

1/ 2"

A P

X

7/ 8"

'-1

1/

2" 6'

-5

/8

'-1

1/

8" 9'

-1

3/ 8"

VFY

3 1/2"

APX

6'-3 5/8" 3'-0" 9'-9 3/8" 2'-2"

APX

13'-4 3/4" VFY

3 1/2"

HOLD CLR

8'-0"

EDGE OF OVERHEAD

SOFFITS AT DASH LINES

LOCATIONS.

EDGE OF OVERHEAD

SOFFITS AT DASH LINES

LOCATIONS.

AE403

C5

AE402

C5

AE401

C5

/D5 AE100

1.15A

1.15C

1.15A

1.15A

1.15B

1.15A1.15A

1.15B

1.15C

1.15C

1.15B

1.15A

1.15B

1.15A1.15A

AE502

C5

AE502

C4

AE502

B5

AE501

C1 ________

AE501

C2

AE501

A2

AE502

C6

AE502

A3

AE502

D4

W3

W3

22.02A

AE502

B4

B B

B

B

B1

B

B1

B

B

B

B

C

C

B

+BD

X

C

C

B

B

B1

B1

B1

BA

BA

CABA

+BD

CA

XA CA

9.51

9.51

9.51

9.51

9.51

9.51

9.51

9.51

9.51 9.51

9.51

9.51

22.02A

6.41

6.41

6.46

6.41

6.41

6.41

9.51

1.15B

B4

AE312

+BD

ALIGN CLR WITH CORRIDOR

8'-0"

B3

AE312

B B

B

X

AE501

B2

C304-01

CORRIDOR

C304-01

CORRIDOR

C304-01

CORRIDOR

D5

AE312

1'-0"

A P

X

'-2

/8

A P

X C

LR

4' -3

/4

3'

-3

/2

BA

BA

B

B

BA

BA

BA

B1

BA

BA

BA

BA

D4

AE312

ALIGN WALL WITH

WDW JAMB

M

IN

2' -1

13'-4 7/8" 11" 8'-6 3/8"

VFY

3 1/2"

120°

150°

ALIGN

BA

BABA

BA

BA

+BA

+BA +BA

X

XA XAXA XA

X

XA

XA

X

X

X

X

X

X

X

X

XA

X

X

B

'-9

/8

9'

-1

/8

1' -8

/2

"11

6' -5

/8

APX

15'-6 3/4" VFY

3 1/2"

VFY

3 1/2" APX

10'-8 1/8" 8'-4 7/8"

APX

7'-11 1/4"

APX

7'-1 3/4"

APX

5 7/8"

VFY

3 1/2"

X XX

BA +BABA

XA

ALIGN

CL

4'-0 5/8"

4'-2 3/8"

B

3'-11 7/8"

1'-2"

BF

AA AA

AA

1' -2

/8

"A P

X

3' -6

/2

AE601

B3

AE601

B5

AE601

B3

AE601

B3

AE601

B3

AE601

B5

CLR

3'-8"

VFY

3 1/2"

APX

11'-3 1/8"

1'-8 3/8"

5 5/8"

2'-2" 4'-0 7/8" 2'-2" 1'-6 3/4" 14'-0"

VFY

7"

VFY

3 1/2"

'-6

/4

1'

-9

6' -7

/2

'-9

'-0

/8

A

P X

7/

8" V

F Y

1/

2"

APX

7'-11 1/4"

APX

7'-7 5/8" VFY

3 1/2"

EQ EQ

C L

4' -0

4'

-0

6"

4' -0

'-4

C L

2' -0

/4

6"

C L

2' -0

/4

2'

-1

1/ 2"

4' -7

2'

-3

/4

4' -0

6"

4' -0

2' -0

/4

6"2' -0

/4

VFY

3 1/2"

APX

6 3/4"

APX

18'-6 1/4" 2'-2"

APX

13'-4 3/4" VFY

3 1/2"

C L

4' -0

B

6' -1

5/

8"

1'-0"

D1

AE502

8.10B

1.05A

1.05B

B1

B

C

LR

3' -0

VFY

3 1/2"

6'-3 5/8"

3'-0"

APX

9'-9 3/8"

M

IN

1' -0

10.37

8.10C

8.10C

22.41

KEY PLAN

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

INDICATED THUS ON

CEILING PLANS

# RATING HEIGHT DESCRIPTION

A NON-RATED FULL-HEIGHT 5/8" GWB, 2 1/2" 20GA MTL STUD, 5/8" GWB

AA NON-RATED FULL-HEIGHT 5/8" GWB, 2 1/2" 20GA MTL STUD

AD NON-RATED TOW 6" AFC 5/8" GWB, 2 1/2" 20GA MTL STUD

B NON-RATED FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

B1 1-HOUR FIRE FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

B1S 1-HOUR F&S FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

BA NON-RATED FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD

BB SMOKE-COR FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

BC SMOKE-HAZ FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

C NON-RATED FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

C1 1-HOUR FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

C1S 1-HOUR F&S FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

CA NON-RATED FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD

CB SMOKE-COR FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

TYPICAL EXTERIOR FURRING

X NON-RATED FULL-HEIGHT 5/8" GWB, VB, 2 1/2" 20 GA MTL STUD, 1" RIGID INSULATION

XA NON-RATED FULL-HEIGHT VB, 2 1/2" 20 GA MTL STUD, 1" RIGID INSULATION

FINISH WALLS & COLUMN WRAPS

+A NON-RATED FULL-HEIGHT 5/8" GWB,

+BA NON-RATED FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BB SMOKE-COR FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BC SMOKE-HAZ FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BD NON-RATED TOW 6" AFC 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

MODIFIER (IF APPLICABLE)

FIRE RATING IN HOURS (IF APPLICABLE)

NOTE

1. FULL-HEIGHT = STRUCT BLW TO STRUCT ABV. SEE DETAILS FOR DEFLECTION GAPS & CHANNELS.

2. VB TO BE INSTALLED IN FURRING & FINISH WALLS AT EXT MASONRY OR CONCRETE WALLS. TIE INTO

EXISTING BARRIERS WHERE APPLICABLE.

3. SAFB TO NOT BE INSTALLED IN 2 1/2", OR SMALLER, STUD WALLS EXCEPT AT SHAFTS, STAIRWELLS, &

EXTERIOR WALLS.

WALL TYPES WALL TAG XX#

SEE SHEET

AE601 FOR

MORE INFO

SCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

(402) 991-5520

NATHAN BOWMAN (MECH & PUMB)

MAY ALEXANDER (ELEC)

BSE ENGINEERS

11320 WEST 79TH STREET

LENEXA, KS 66214

(913) 492-7400

KEVIN BOEHRINGER (STRUCT)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

2_ M ar io n V

A _R en ov at e

3B _k yl ek

9D U

H U

.rv t

9/

/2

:4 7:

A

M

AE101

ARCHITECTURAL FLOOR PLAN - 3RD LEVEL -

AREA A

STONE / HFG ARCHITECTURE

600 EAST 7TH ST & 330 N. MEAD

SIOUX FALLS, SD 57103 & WICHITA, KS 67202

(605) 271-1144 & (316) 262-2500

BEAU FEY (ARCH) & WAYNE BONGARTZ (PM)

RENOVATE PATIENT WARD 3B

FOR PATIENT PRIVACY AND

INTENSIVE CARE

MARION IL

BLDG #001

WESLEY PINKS

09/20/2024 BF/WB/SS KK/AB/AW

SGA #231942

VA #657A5-23-110

FINAL BID DOCUMENTS

ARCH SHEET: 2 OF 26

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.05A PAINT EXISTING DOOR FRAME PT-2

1.05B PAINT BOTH SIDES OF EXISTING HM DOOR PANEL PT-2

1.15A EXISTING WINDOW. REMOVE EXISTING INTERIOR SEALANT & RESEAL.

1.15B EXISTING WINDOW. REMOVE EXISTING INTERIOR SEALANT & RESEAL. REMOVE EXISTING

BLACKOUT FILM & CLEAN WINDOW.

1.15C EXISTING WINDOW. REMOVE EXISTING INTERIOR SEALANT & RESEAL. APPLY BLACKOUT FILM

PER FACILITY STANDARD.

6.41 COUNTERTOP - SEE AI SHEETS.

6.46 SOLID SURFACE WRAP - SEE AI SHEETS.

8.10B REINSTALL WINDOW THAT WAS REMOVED FROM SPECIFIED LOCATION DURING DEMOLITION.

REPAIR ALL DAMAGE CAUSED BY CONSTRUCTION AT THE WINDOW OPENING. REPAIR AND/OR

REPLACE FLASHING, WEATHER PROOFING, INSULATION, AND EXTERIOR FINISH AS NEEDED.

8.10C HOLLOW METAL WINDOW SYSTEM - SEE WDW LEGEND.

9.51 SOLID SURFACE WINDOW SILL - SEE SCHEDULE.

10.37 RESIN PANEL - SEE AI SHEETS.

10.40A SEMI-RECESSED WALL MOUNTED F.E.C. - SEE DETAILS.

22.02A SINGLE BASIN SINK - SEE PLUMBING & AI SHEETS.

22.41 EYEWASH STATION - SEE PLUMBING.

1/4" = 1'-0" D5

FLOOR PLAN - 3RD LEVEL - AREA A

PROCEEDING WITH THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. FREE-STANDING FURNITURE IS PROVIDED AND INSTALLED BY OTHERS.

D. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

E. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.

F. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.

G. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.

H. PROVIDE BACKING FOR ALL TOILET ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED TO

BUILDING WALLS.

I. INSTALL BLOCKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING,

MARKERBOARDS, WALL MOUNTED MONITORS/TVS, COUNTERTOP SUPPORTS, ETC.

J. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD.

K. PROVIDE CONTROL JOINTS IN DRYWALL EVERY 30'-0".

L. ALL DIMENSIONS ARE TO OUTSIDE OF WALL FRAMING.

M. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

N. SEE SHEET AE601, ARCHITECTURAL SCHEDULES & ASSEMBLIES, FOR MORE INFORMATION

REGARDING DOORS, WINDOWS, AND WALL TYPES.

O. CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY EXISTING STRUCTURAL MEMBERS WHICH MAY

CONFLICT WITH THE DESIGNED WALL LAYOUT AND/OR DESIGNED PLUMBING LOCATIONS BEFORE ANY

WALLS ARE CONSTRUCTED.

P. CONTRACTOR TO NOTIFY ARCHITECT OF LOCATIONS WHERE PENETRATIONS IN THE FLOOR MAY INTERSECT AND/OR INTERFERE WITH THE INTERGITY OF EXISTING CONCRETE JOISTS. WHERE MEP SYSTEMS CANNOT BE EASILY REROUTED WITHIN ALREADY DESIGNED WALLS, CEILINGS, OR CHASES, THE A/E TEAM WILL REVISE AND REISSUE DRAWINGS SO AS TO AVOID CONFLICTS WITH THE EXISTING

JOISTS.

GENERAL PLAN NOTES

RR

GG

M

KK

JJ

HH

F

D

A

E

S301-01

STAIR

NA

SEISMIC

TOWER B

NA

SHAFT B

P-7

ELEVATOR

S302-01

STAIR

71 SF

VISITOR TLT

180 SF

VISITOR

LOUNGE

140 SF

CONSULTATION

97 SF

STAFF

LOCKERS

57 SF

304A

STAFF TLT

57 SF

304B

STAFF TLT

186 SF

MULTI-PURPOSE

111 SF

CLEAN

UTILITY

189 SF

LOGISTICS

120 SF

MEDICATION

APX CLR

7'-0 3/4"

M A

T C

H E

X S

T C

LR

7' -0

/4

124 SF

SOILED

UTILITY

69 SF

HAC

171 SF

ICU

COMMAND

CENTER

51 SF

CLEAN

LINEN

49 SF

322A

PATIENT

TLT

276 SF

ICU PATIENT

ROOM

285 SF

ICU PATIENT

ROOM

49 SF

319A

PATIENT

TLT

317 SF

NURSE

STATION

35 SF

EQUIPMENT

ALCOVE

8 SF

STATION

ALCOVEC302-01

CORRIDOR

ELEVATOR

LOBBY

C303-01

CORRIDOR

C304-01

CORRIDOR

23 SF

ELEC

242 SF

MED/SURG

PATIENT

ROOM

85 SF

303A

PATIENT

TLT

38 SF

EQUIPMENT

ALCOVE

4A

4B

9A

2A

D1

AE311

B3

AE311

B2

AE311

B4

AE311

D2

AE311

B5

AE312

W3

W3

10.40A

EQ EQ

HOLD CLR

8'-0"

1'-7 1/4" 15'-8 3/4"

EDGE OF OVERHEAD

SOFFITS AT DASH

LINES LOCATIONS.

EDGE OF OVERHEAD

SOFFITS AT DASH LINES

LOCATIONS.

11'-8 3/4" 11'-3 5/8"

3 1/2"

7' -6

5'

-1 0"

6' -7

/8

V

F Y

1/

2"

2' -3

/4

VFY

3 1/2"

APX

12'-2 3/8"

1'

M

IN

8"

A P

X

5' -1

3/

8" V

F Y

1/

2"

AE411

B3

AE405

C5

AE404

C5

AE406

C5

D5

AE311

/D5 AE100

1.15A 1.15A

1.15A

1.15A 1.15A

1.15A

1.15C

1.15A

1.15C

1.15C

1.15B

1.15A

1.15B

AE501

D1

AE502

A4

AE502

A5

C

LR

2' -6

M

IN

6.41

6.41

6.41

6.46

9.51

BC

BC

BC

AD

B

C1

BC

B

B1

AD

B1 B1

B1S

BS1

B1S

B +A

+A

B1

B1

B

B

AA

B

B

B

B

B

+BA

BA

B

B

C

C

B

B

B

+BA

CA

AA AA

+BD

+BD

BA

CA

BF

C1

BC

BA

9.51

9.51

1.15A

9.51

9.51

9.51 9.51

9.51

+BA

2'-2"

A P

X C

LR

3' -1

7/

8"

VFY

3 1/2"

APX

6 3/4"

APX

18'-6 1/4" 2'-2"

APX

13'-4 3/4" VFY

3 1/2"

+BA

B B

ADJUST FURRING AS NEED TO ALIGN

WITH PARTITIONS ON OPPOSITE

SIDE OF CORRIDOR.

B4

AE312

9.51

9.51

1.15C

1.15A

1.15A

C302-01

303A

+BD

+BA

BB

BB

BB

W3

APX

9'-0 7/8" 8'-0 1/8" 2'-2 5/8"

V F

Y

1/ 2"

6' -6

/8

8'

-1

/8

BABA

B

B

+BA

1.10A

AE411

D3

10 3/8" 8'-9 3/8" 8'-0" 13'-10 1/8"

APX

8'-11 3/8"

B

1'-0" MIN CLR

B3

AE312

AE411

B5

BC

BC

B

B

CA

BA

+BA

APX

7'-11 1/4"

APX

7'-7 5/8"

3 1/2"

AA

BA

BA

AE502

D3

AE502

C3

AE502

A2

AE502

B2

AE411

D5

AE502

C2

22.02A

B

1' -7

/8

A

P X

4' -7

/8

8'

-2

/2

BA

BA

B1S

B1S

9'-6 5/8" 6'-6 3/8"

135°

135°

BB

BB

14'-8 1/2"

APX

9'-6 7/8"

+BD B

B1B1B1

BS1

B

BA

B1BA

B

BA

BA

BA

+BA

BC

B1

AE312

B2

AE312

D2

AE312

D3

AE312

9.51 9.51

22.31

22.44

APX

2'-5 1/2" 2'-0"

D1

AE312

5'-3 1/2" 3'-1"

AE502

C1

ADJACENT BUILDING

BA BA BA BA

BA

X

X

X

X

XA

X

X

X

XA

X

X

XA

X

X

XA

XA

XXXAX

XA

X

XA

BA

BA

XAXA X XAXA

X

+BABA

X X

BA +BA

X X

BA

+BA

+BAAA

V F

Y

1/ 2"

A P

X

'-8

/4

A P

X

7' -5

/8

1'

-5

A P

X

'-6

/8

V

F Y

1/

2"

BA

4'-0" MIN CLR

4'-0 1/4"

ALIGN WALL WITH WDW

JAMB UNLESS MIN CLR

IS NOT POSSIBLE.

7'-9" 11"11" 7'-9"

ALIGN

+BA

ALIGN

BA

BA

1' -2

APX

6'-2 1/4"

1' -7

/8

"5' -4

/8

7'

-1

3/ 8"

16'-1"

CL

6'-10 3/4" 5'-1 3/8" 3'-0 1/4"

APX

3'-9 3/8"

1'

M

IN

2' -8

/8

APX

3'-9 1/4" E

Q E

Q

BA

BA

7'-5 5/8" 4'-3 1/8"

C L

7' -9

HOLD CLR

8'-0"

AE601

B3

V F

Y

AE502

A5

AE502

A5

AE601

B3

AE502

A5

AE601

B3

AE601

B5

AE601

B3

AE502

B3

AE502

B3

AE502

B3

+BD

AE601

B5

AE601

B5

AE601

B5

9.51

9.51

2'-5 3/8"

1/

2"

7/

8" 6"

'-0

/8

6'

-1

1/ 4"

1' -1

/8

'-4

/8

6'

-1

1/ 4"

'-1

1/

2" A

P X

7/

8"

V F

Y

1/ 2"

2' -0

EQ EQ

C L

7' -9

2' -3

/4

C

L

2' -0

/4

2'

-0

/4

A P

X

5' -6

/8

A P

X

5' -8

/8

4'

-0

CL

1'-7 5/8" 4'-10 3/4"

TELEMETRY

C301-01

CORRIDOR

NO NEW ARCHITECTURAL CONSTRUCTION OR

DEMOLITION WEST OF DASHED LINE. WORK

WEST OF PROJECT AREA IS AT CEILINGS ONLY -

SEE DEMO RCPS AND MEP DRAWINGS.

HAC

8.10B 8.10B

EQ EQ

AE501

C5

AE501

B5

1.05A

1.05B

10.37

8.10C

8.10C

8.10C

ADJUST FURRING

LOCATION AS NEEDED

TO ENCLOSE EXST PIPE.

M

IN

1' -6

KEY PLAN

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

INDICATED THUS ON

CEILING PLANS

# RATING HEIGHT DESCRIPTION

A NON-RATED FULL-HEIGHT 5/8" GWB, 2 1/2" 20GA MTL STUD, 5/8" GWB

AA NON-RATED FULL-HEIGHT 5/8" GWB, 2 1/2" 20GA MTL STUD

AD NON-RATED TOW 6" AFC 5/8" GWB, 2 1/2" 20GA MTL STUD

B NON-RATED FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

B1 1-HOUR FIRE FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

B1S 1-HOUR F&S FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

BA NON-RATED FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD

BB SMOKE-COR FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

BC SMOKE-HAZ FULL-HEIGHT 5/8" GWB, 3 5/8" 20GA MTL STUD, 5/8" GWB

C NON-RATED FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

C1 1-HOUR FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

C1S 1-HOUR F&S FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

CA NON-RATED FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD

CB SMOKE-COR FULL-HEIGHT 5/8" GWB, 6" 20GA MTL STUD, 5/8" GWB

TYPICAL EXTERIOR FURRING

X NON-RATED FULL-HEIGHT 5/8" GWB, VB, 2 1/2" 20 GA MTL STUD, 1" RIGID INSULATION

XA NON-RATED FULL-HEIGHT VB, 2 1/2" 20 GA MTL STUD, 1" RIGID INSULATION

FINISH WALLS & COLUMN WRAPS

+A NON-RATED FULL-HEIGHT 5/8" GWB,

+BA NON-RATED FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BB SMOKE-COR FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BC SMOKE-HAZ FULL-HEIGHT 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

+BD NON-RATED TOW 6" AFC 5/8" GWB, 1 5/8" MTL STUD, EXST OR OTHER WALL

MODIFIER (IF APPLICABLE)

FIRE RATING IN HOURS (IF APPLICABLE)

NOTE

1. FULL-HEIGHT = STRUCT BLW TO STRUCT ABV. SEE DETAILS FOR DEFLECTION GAPS & CHANNELS.

2. VB TO BE INSTALLED IN FURRING & FINISH WALLS AT EXT MASONRY OR CONCRETE WALLS. TIE INTO

EXISTING BARRIERS WHERE APPLICABLE.

3. SAFB TO NOT BE INSTALLED IN 2 1/2", OR SMALLER, STUD WALLS EXCEPT AT SHAFTS, STAIRWELLS, &

EXTERIOR WALLS.

WALL TYPES WALL TAG XX#

SEE SHEET

AE601 FOR

MORE INFO

SCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

(402) 991-5520

NATHAN BOWMAN (MECH & PUMB)

MAY ALEXANDER (ELEC)

BSE ENGINEERS

11320 WEST 79TH STREET

LENEXA, KS 66214

(913) 492-7400

KEVIN BOEHRINGER (STRUCT)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

2_ M ar io n V

A _R en ov at e

3B _k yl ek

9D U

H U

.rv t

9/

/2

:4 7:

A

M

AE102

ARCHITECTURAL FLOOR PLAN - 3RD LEVEL -

AREA B

STONE / HFG ARCHITECTURE

600 EAST 7TH ST & 330 N. MEAD

SIOUX FALLS, SD 57103 & WICHITA, KS 67202

(605) 271-1144 & (316) 262-2500

BEAU FEY (ARCH) & WAYNE BONGARTZ (PM)

RENOVATE PATIENT WARD 3B

FOR PATIENT PRIVACY AND

INTENSIVE CARE

MARION IL

BLDG #001

WESLEY PINKS

09/20/2024 BF/WB/SS KK/AB/AW

SGA #231942

VA #657A5-23-110

FINAL BID DOCUMENTS

ARCH SHEET: 3 OF 26

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.05A PAINT EXISTING DOOR FRAME PT-2

1.05B PAINT BOTH SIDES OF EXISTING HM DOOR PANEL PT-2

1.10A EXISTING EXPANSION JOINT. FLOOR AND ROOF STRUCTURE ASSEMBLY TO REMAIN AS IS.

DAMAGED SEALANT AND/OR MORTAR EXPOSED BY CONSTRUCTION TO BE PATCHED OR

REPLACED. NEW CEILING AND/OR WALL ASSEMBLIES AT JOINT TO BE CONSTRUCTED

ACCORDING TO PROVIDED DETAILS.

1.15A EXISTING WINDOW. REMOVE EXISTING INTERIOR SEALANT & RESEAL.

1.15B EXISTING WINDOW. REMOVE EXISTING INTERIOR SEALANT & RESEAL. REMOVE EXISTING

BLACKOUT FILM & CLEAN WINDOW.

1.15C EXISTING WINDOW. REMOVE EXISTING INTERIOR SEALANT & RESEAL. APPLY BLACKOUT FILM

PER FACILITY STANDARD.

6.41 COUNTERTOP - SEE AI SHEETS.

6.46 SOLID SURFACE WRAP - SEE AI SHEETS.

8.10B REINSTALL WINDOW THAT WAS REMOVED FROM SPECIFIED LOCATION DURING DEMOLITION.

REPAIR ALL DAMAGE CAUSED BY CONSTRUCTION AT THE WINDOW OPENING. REPAIR AND/OR

REPLACE FLASHING, WEATHER PROOFING, INSULATION, AND EXTERIOR FINISH AS NEEDED.

8.10C HOLLOW METAL WINDOW SYSTEM - SEE WDW LEGEND.

9.51 SOLID SURFACE WINDOW SILL - SEE SCHEDULE.

10.37 RESIN PANEL - SEE AI SHEETS.

10.40A SEMI-RECESSED WALL MOUNTED F.E.C. - SEE DETAILS.

22.02A SINGLE BASIN SINK - SEE PLUMBING & AI SHEETS.

22.31 MOP SINK - SEE PLUMBING.

22.44 WALL MOUNTED CLINICAL SERVICE SINK W/ LEFT SIDE FLUSH ROD - SEE PLUMBING.

1/4" = 1'-0" D5

FLOOR PLAN - 3RD LEVEL - AREA B

ID

S

AT

F

F

F

D

D

D

D

D

D

F

FS

AT

AT

S

AT

AT

AT

ATAT

S

AT

AT

AT

F

S

AT CC

AT AT

AT

AT

F

ATAT

F

SAT

C

S AT AT F

S

AT AT

AT

AT

TV

D

T V

TV

T V

TV

TV

TV

T V

T V

T V

T V

AC

AC

A C

A C

A C

A C

A C

AC

AC

AC

C

C

C

C

C

S

TV

DO

S

S

S

S

S

S

SS

S

S S

S

S

A. ANY DISCREPANCIES FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECTS AND THE OWNER BEFORE PROCEEDING WITH ALL

THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. ALL ITEMS INSTALLED IN CEILINGS ARE TO BE CENTERED AND/OR SYMMETRICAL ON THE CENTERLINE

OF ROOMS AND CENTERED IN TILES UON.

D. INSTALL ALL WALL MOUNTED EXIT SIGNS AND OTHER FIXTURES CENTERED ABOVE OPENINGS WHERE

POSSIBLE.

E. REFLECTED CEILING PLANS SHOW LOCATIONS OF ITEMS THAT ARE ARCHITECTURALLY SIGNIFICANT

ONLY. MECHANICAL AND ELECTRICAL ITEMS INDICATED ARE FOR REFERENCE ONLY. REFER TO

MECHANICAL AND ELECTRICAL DOCUMENTS.

F. GYPSUM USED IN RESTROOM AND OTHER AREAS EXPOSED TO MOISTURE SHALL BE WATER

RESISTANT GYPSUM BOARD.

G. VA STANDARD CEILING HEIGHT REQUIREMENTS NOT MET. CONFIRM EXEMPTION REQUEST HAS BEEN

APPROVED BY FACILITY COR.

H. ALL ACCESS PANELS TO BE PAINTED COLOR AND SHEEN OF ADJACENT CEILING FINISH.

I. WHERE DAMAGED AS RESULT OF DEMOLITON WORK AND/OR INSTALLATION OF NEW MEP SYSTEMS, CONTRACTOR IS TO REPLACE EXISTING CEILING TILE AND/OR SUSPENDED CEILING GRIDS.

J. CONTRACTOR TO NOTIFY THE COR & ARCHITECT IF CEILING MOUNTED FIXTURES, AND/OR

EQUIPMENT, WILL OBSTRUCT THE VIEW OF EXIT SIGNAGE. CONTRACTOR, COR, & A/E TEAM TO

REVIEW AND COORDINATE RESOLUTION.

GENERAL REFLECTED CEILING PLAN NOTES

AE111

D5

AE112

D5

S301-01

STAIR

P-2

ELEVATOR

OXYGEN

STORAGE

OFFICE

PHARMACY

LOGISTICS

NOURISHMENT

339A

ELEC

NURSE

MANAGER

S303-01

STAIR

PATIENT

BEDROOM

342A

BATH

PATIENT

BEDROOM

344A

BATH

343A

BATH

PATIENT

BEDROOM

NURSES

STATION

345B

CLEAN

LINEN

345C

SOILED

LINEN

345A

LOCKER

345D

STAFF RR

345E

STORAGE

345F

CORRIDOR

345G

JANITOR

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ICU

BEDROOM

ANTE

ICU

BEDROOM

NURSES

STATION

C306-01

CORRIDOR

ICU

BEDROOM

STAFF

LOCKER

SOILED

UTILITY

ELEC

HAC

C305-01

CORRIDOR

C305-01

CORRIDOR

C307-01

CORRIDOR

PATIENT

BEDROOM

361A

BATH

PATIENT

BEDROOM

PATIENT

BEDROOM

362A

BATH

363A

BATH

C307-01

CORRIDOR

340A

CLOSET

NA

SEISMIC

TOWER A

NA

SEISMIC

TOWER B

NA

SHAFT B

NA

SHAFT A

S305-01

STAIR

P-7

ELEVATOR

S302-01

STAIR

P-1

ELEVATOR

S304-01

STAIR

NURSES

STATION

NURSES

STATION

304B

STAFF TLT

STAFF

LOCKERS

LOGISTICS

CLEAN

UTILITY

SOILED

UTILITY

CLEAN

LINEN

NOURISHMENT

EQUIPMENT

309A

WORKSTATIONS

ELEC

CONSULTATION

VISITOR

LOUNGE

VISITOR TLT

MEDICATION

304A

STAFF TLT

MULTI-PURPOSE

ICU

COMMAND

CENTER

HAC

NURSE

STATION

E Q

U

IP

M E

N T

A

LC

O V

E

314A

ISO /

BARIATRIC

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ANTE ROOM

314B

ISO /

BARIATRIC

TLT

316A

PATIENT

TLT

317A

PATIENT

TLT

319A

PATIENT

TLT

322A

PATIENT

TLT

C301-01

CORRIDOR

ELEC

STATION

ALCOVE

STATION

ALCOVE

ELEVATOR

LOBBY

C302-01

CORRIDOR

C

3-

C O

R R

ID

O

R

C

4-

C O

R R

ID

O

R

C304-01

CORRIDOR

EQUIPMENT

ALCOVE

E Q

U

IP

M E

N T

A

LC

O V

E

MED/SURG

PATIENT

ROOM

303A

PATIENT

TLT

STATION

ALCOVE

B6

AE301

B2

AE301

D6

AE301

C

4-

C O

R R

ID

O

R

1.10A1.10A

ADJACENT BUILDING

NO NEW ARCHITECTURAL CONSTRUCTION OR

DEMOLITION WEST OF DASHED LINE. WORK

WEST OF PROJECT AREA IS AT CEILINGS ONLY -

SEE DEMO RCPS AND MEP DRAWINGS.

PATIENT

BEDROOM

364A

BATH

RECEPTION

/ NURSES

STATION

301A

WORK AREA

TELEMETRY

LOCKER

C301-01

CORRIDOR

C301-01

CORRIDOR

HAC

KEY PLAN - FLOOR - OVERALL

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

SCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

CEILING ACCESS PANEL

2X4 FLUORESCENT FIXTURE

2X2 FLUORESCENT FIXTURE

CEILING HEIGHT

RECESSED CAN FIXTURE

RETURN AIR GRILLE

SUPPLY AIR GRILLE

X'-X"

WIRELESS ACCESS POINT

AT ANTENNA

DOME LIGHT

AC ACCESS CONTROLLED DOOR

D

F HORN/ STROBE

TV ROUGH-IN TELEVISION OUTLET

SECURITY CAMERAC

CEILING SPEAKERS

EXIT SIGN

NOTE

A. REFERENCE MECHANICAL & ELECTRICAL DRAWINGS FOR SYMBOLS NOT SHOWN HERE.

RCP SYMBOLS & MATERIALS LEGEND

GYPSUM CEILING

(GWB)

2X2 SUSPENDED

ACOUSTICAL TILE

CEILING (SAT)

2X4 SUSPENDED

ACOUSTICAL TILE

CEILING (SAT)

X.XX KEYNOTE - SEE SCHEDULE

OR

RECESSED LINEAR LIGHT

VANITY LIGHTOR

OR

OR

OR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

(402) 991-5520

NATHAN BOWMAN (MECH & PUMB)

MAY ALEXANDER (ELEC)

BSE ENGINEERS

11320 WEST 79TH STREET

LENEXA, KS 66214

(913) 492-7400

KEVIN BOEHRINGER (STRUCT)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

2_ M ar io n V

A _R en ov at e

3B _k yl ek

9D U

H U

.rv t

9/

/2

:4 8:

A

M

AE110

REFLECTED CEILING PLAN - 3RD LEVEL -

OVERALL

STONE / HFG ARCHITECTURE

600 EAST 7TH ST & 330 N. MEAD

SIOUX FALLS, SD 57103 & WICHITA, KS 67202

(605) 271-1144 & (316) 262-2500

BEAU FEY (ARCH) & WAYNE BONGARTZ (PM)

RENOVATE PATIENT WARD 3B

FOR PATIENT PRIVACY AND

INTENSIVE CARE

MARION IL

BLDG #001

WESLEY PINKS

09/20/2024 BF/WB/SS KK/AB/AW

SGA #231942

VA #657A5-23-110

FINAL BID DOCUMENTS

ARCH SHEET: 4 OF 26

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.10A EXISTING EXPANSION JOINT. FLOOR AND ROOF STRUCTURE ASSEMBLY TO REMAIN AS IS.

DAMAGED SEALANT AND/OR MORTAR EXPOSED BY CONSTRUCTION TO BE PATCHED OR

REPLACED. NEW CEILING AND/OR WALL ASSEMBLIES AT JOINT TO BE CONSTRUCTED

ACCORDING TO PROVIDED DETAILS.

1/8" = 1'-0" D5

REFLECTED CEILING PLAN - 3RD LEVEL -

OVERALL

F

D

D

D

D

FS

AT

AT

S

AT

AT

AT

ATAT

S

AT

AT

AT

TV

TV

T V

T V

T V

T V

AC

AC

A C

C

C

S

S

S

A. ANY DISCREPANCIES FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECTS AND THE OWNER BEFORE PROCEEDING WITH ALL

THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. ALL ITEMS INSTALLED IN CEILINGS ARE TO BE CENTERED AND/OR SYMMETRICAL ON THE CENTERLINE

OF ROOMS AND CENTERED IN TILES UON.

D. INSTALL ALL WALL MOUNTED EXIT SIGNS AND OTHER FIXTURES CENTERED ABOVE OPENINGS WHERE

POSSIBLE.

E. REFLECTED CEILING PLANS SHOW LOCATIONS OF ITEMS THAT ARE ARCHITECTURALLY SIGNIFICANT

ONLY. MECHANICAL AND ELECTRICAL ITEMS INDICATED ARE FOR REFERENCE ONLY. REFER TO

MECHANICAL AND ELECTRICAL DOCUMENTS.

F. GYPSUM USED IN RESTROOM AND OTHER AREAS EXPOSED TO MOISTURE SHALL BE WATER

RESISTANT GYPSUM BOARD.

G. VA STANDARD CEILING HEIGHT REQUIREMENTS NOT MET. CONFIRM EXEMPTION REQUEST HAS BEEN

APPROVED BY FACILITY COR.

H. ALL ACCESS PANELS TO BE PAINTED COLOR AND SHEEN OF ADJACENT CEILING FINISH.

I. WHERE DAMAGED AS RESULT OF DEMOLITON WORK AND/OR INSTALLATION OF NEW MEP SYSTEMS, CONTRACTOR IS TO REPLACE EXISTING CEILING TILE AND/OR SUSPENDED CEILING GRIDS.

J. CONTRACTOR TO NOTIFY THE COR & ARCHITECT IF CEILING MOUNTED FIXTURES, AND/OR

EQUIPMENT, WILL OBSTRUCT THE VIEW OF EXIT SIGNAGE. CONTRACTOR, COR, & A/E TEAM TO

REVIEW AND COORDINATE RESOLUTION.

GENERAL REFLECTED CEILING PLAN NOTES

D

A

E

S304-01

STAIR

NOURISHMENT

EQUIPMENT

309A

WORKSTATIONS

ELEC

NURSE

STATION

314A

ISO /

BARIATRIC

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ICU PATIENT

ROOM

ANTE ROOM

314B

ISO /

BARIATRIC

TLT

316A

PATIENT

TLT

317A

PATIENT

TLT

STATION

ALCOVE

STATION

ALCOVE

C304-01

CORRIDOR

C304-01

CORRIDOR

EQUIPMENT

ALCOVE

C304-01

CORRIDOR

B2

AE311

D4

AE311

B5

AE311

D3

AE311

B5

AE312

B1

AE311

9.25

9.25

9.25

3'-0"

2'-2"

2'-2"

/D5 AE110

B4

AE312

10.36

10.36

10.36

10.36

10.36

10.3610.36

10.36

10.36

10.36

10.36

10.36

B3

AE312

A4

AE501

D5

AE312

9.25

9.25

9.25

9.25

9.25

8'-4 7/8" 2'-0" 8'-0"

10.37

9.25

D4

AE312

TYP

1'-4"

TYP

1'-4"

TYP

1'-4"

T Y

P 1"

TYP

1"

AE401

C2

AE402

C2

AE403

C2

3' -2

/2

9.21

9.21

9.21

9.21

9.26

9.26

9.26

T Y

P

1' -4

C3

AE501

9.21

4 7/8"

2'-0"

7' - 10"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

9.25

7' - 10"

9.21

7' - 0"

8' - 0"

8' - 0"

8' - 0"

7' - 6"

8' - 0"

7' - 4"

8' - 0"

8' - 0"

7' - 6"

10.36

7' - 10"

9.26

9.26

9.25

9.25

8' - 0"

PT-5

PT-6

PT-4

PT-5

9.20A

9.25

7' - 10"

9.26

3'-0"

PT-6

9.26

6.36

6.36

6.36

6.36

6.36

6.36

6.36

6.36

KEY PLAN

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

SCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

CEILING ACCESS PANEL

2X4 FLUORESCENT FIXTURE

2X2 FLUORESCENT FIXTURE

CEILING HEIGHT

RECESSED CAN FIXTURE

RETURN AIR GRILLE

SUPPLY AIR GRILLE

X'-X"

WIRELESS ACCESS POINT

AT ANTENNA

DOME LIGHT

AC ACCESS CONTROLLED DOOR

D

F HORN/ STROBE

TV ROUGH-IN TELEVISION OUTLET

SECURITY CAMERAC

CEILING SPEAKERS

EXIT SIGN

NOTE

A. REFERENCE MECHANICAL & ELECTRICAL DRAWINGS FOR SYMBOLS NOT SHOWN HERE.

RCP SYMBOLS & MATERIALS LEGEND

GYPSUM CEILING

(GWB)

2X2 SUSPENDED

ACOUSTICAL TILE

CEILING (SAT)

2X4 SUSPENDED

ACOUSTICAL TILE

CEILING (SAT)

X.XX KEYNOTE - SEE SCHEDULE

OR

RECESSED LINEAR LIGHT

VANITY LIGHTOR

OR

OR

OR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

(402) 991-5520

NATHAN BOWMAN (MECH & PUMB)

MAY ALEXANDER (ELEC)

BSE ENGINEERS

11320 WEST 79TH STREET

LENEXA, KS 66214

(913) 492-7400

KEVIN BOEHRINGER (STRUCT)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

2_ M ar io n V

A _R en ov at e

3B _k yl ek

9D U

H U

.rv t

9/

/2

:4 8:

A

M

AE111

REFLECTED CEILING PLAN - 3RD LEVEL -

AREA A

STONE / HFG ARCHITECTURE

600 EAST 7TH ST & 330 N. MEAD

SIOUX FALLS, SD 57103 & WICHITA, KS 67202

(605) 271-1144 & (316) 262-2500

BEAU FEY (ARCH) & WAYNE BONGARTZ (PM)

RENOVATE PATIENT WARD 3B

FOR PATIENT PRIVACY AND

INTENSIVE CARE

MARION IL

BLDG #001

WESLEY PINKS

09/20/2024 BF/WB/SS KK/AB/AW

SGA #231942

VA #657A5-23-110

FINAL BID DOCUMENTS

ARCH SHEET: 5 OF 26

KEYNOTES

KEY VALUE KEYNOTE TEXT

6.36 VERTICAL GWB EXPANSION JOINT.

9.20A 5/8" GYPSUM BOARD, TYPE "C"

9.21 SUSPENDED CEILING TILE - SEE RCP.

9.25 GWB SOFFIT WALL - SEE DETAILS.

9.26 GWB & MTL STUD CEILING - SEE RCP.

10.36 WINDOW ROLLER SHADE - SEE SCHEDULE.

10.37 RESIN PANEL - SEE AI SHEETS.

1/4" = 1'-0" D5

REFLECTED CEILING PLAN - 3RD LEVEL - AREA A

ID

S

AT

F

F

F

D

D

D

F

AT

AT

F

S

AT CC

AT AT

AT

AT

F

ATAT

F

SAT

C

S AT AT F

S

AT AT

AT

AT

TV

D

T V

TV

T V

TV

T V

A C

A C

A C

A C

AC

AC

AC

C

C

C

S

TV

DO

S

S

S

S

S

SS

S

S S

A. ANY DISCREPANCIES FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECTS AND THE OWNER BEFORE PROCEEDING WITH ALL

THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. ALL ITEMS INSTALLED IN CEILINGS ARE TO BE CENTERED AND/OR SYMMETRICAL ON THE CENTERLINE

OF ROOMS AND CENTERED IN TILES UON.

D. INSTALL ALL WALL MOUNTED EXIT SIGNS AND OTHER FIXTURES CENTERED ABOVE OPENINGS WHERE

POSSIBLE.

E. REFLECTED CEILING PLANS SHOW LOCATIONS OF ITEMS THAT ARE ARCHITECTURALLY SIGNIFICANT

ONLY. MECHANICAL AND ELECTRICAL ITEMS INDICATED ARE FOR REFERENCE ONLY. REFER TO

MECHANICAL AND ELECTRICAL DOCUMENTS.

F. GYPSUM USED IN RESTROOM AND OTHER AREAS EXPOSED TO MOISTURE SHALL BE WATER

RESISTANT GYPSUM BOARD.

G. VA STANDARD CEILING HEIGHT REQUIREMENTS NOT MET. CONFIRM EXEMPTION REQUEST HAS BEEN

APPROVED BY FACILITY COR.

H. ALL ACCESS PANELS TO BE PAINTED COLOR AND SHEEN OF ADJACENT CEILING FINISH.

I. WHERE DAMAGED AS RESULT OF DEMOLITON WORK AND/OR INSTALLATION OF NEW MEP SYSTEMS, CONTRACTOR IS TO REPLACE EXISTING CEILING TILE AND/OR SUSPENDED CEILING GRIDS.

J. CONTRACTOR TO NOTIFY THE COR & ARCHITECT IF CEILING MOUNTED FIXTURES, AND/OR

EQUIPMENT, WILL OBSTRUCT THE VIEW OF EXIT SIGNAGE. CONTRACTOR, COR, & A/E TEAM TO

REVIEW AND COORDINATE RESOLUTION.

GENERAL REFLECTED CEILING PLAN NOTES

D

A

E

S301-01

STAIR

NA

SEISMIC

TOWER B

NA

SHAFT B

P-7

ELEVATOR

S302-01

STAIR

304B

STAFF TLT

STAFF

LOCKERS

LOGISTICS

CLEAN

UTILITY

SOILED

UTILITY

CLEAN

LINEN

CONSULTATION

VISITOR

LOUNGE

VISITOR TLT

MEDICATION

304A

STAFF TLT

MULTI-PURPOSE

ICU

COMMAND

CENTER

HAC

NURSE

STATION

EQUIPMENT

ALCOVE

ICU PATIENT

ROOM

ICU PATIENT

ROOM

319A

PATIENT

TLT

322A

PATIENT

TLT

C301-01

CORRIDOR

ELEC

STATION

ALCOVE

ELEVATOR

LOBBY

C302-01

CORRIDOR

C303-01

CORRIDOR

EQUIPMENT

ALCOVE

MED/SURG

PATIENT

ROOM

303A

PATIENT

TLT

STATION

ALCOVE

C304-01

CORRIDOR

D1

AE311

B3

AE311

B2

AE311

B4

AE311

D2

AE311

9.25

9.25

9.25

9.25

B5

AE312

C6

AE503

2'-2"

TYP

4 7/8"

D5

AE311

/D5 AE110

B4

AE312

10.36

10.36

10.36

10.36

10.36

10.36

10.36

10.3610.36

10.36

10.3610.36

9.25

C3

AE501

1.10A

B3

AE312

10.37

9.25

9.25

9.25

A P

X

4' -8

/8

9.25

B1

AE312

B2

AE312

D2

AE312

D3

AE312

TYP

1'-4"

10.3610.36

AE404

C2

AE405

C2

AE406

C2

APX

3'-8 3/8"

TYP

2'-0"

8.04C

8.04C 8.04C

8.04C

8.04C

9.21

9.21

9.21

9.26 9.26

9.21 9.21

9.219.26 9.26

9.21

9.21

9.21

9.21

9.21

9.21

9.26

9.26

9.21

9.21

9.21

9.26

9.26

9.26

9.21

9.21

D1

AE312

ADJACENT BUILDING

7/

8"

4 7/8"

C3

AE501

C3

AE501

C3

AE501

APX

3'-6"

APX

3'-6"

6"

EQ EQ

9.20A

ALIGN

ALIGN

ALIGN

NO NEW ARCHITECTURAL CONSTRUCTION OR

DEMOLITION WEST OF DASHED LINE. WORK

WEST OF PROJECT AREA IS AT CEILINGS ONLY -

SEE DEMO RCPS AND MEP DRAWINGS.

TELEMETRY

C301-01

CORRIDOR

HAC

C302-01

CORRIDOR

7' - 6"7' - 10"

7' - 4"

7' - 4"

8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0" 8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

7' - 6"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 0"

7' - 10"

7' - 10"

7' - 0"

7' - 10"

8' - 0"

7' - 0"

4 7/8"

2'-0"

8' - 0"

7' - 6"

9.26

A P

X

1' -7

/8

9.26

ALIGN

8.04C

8.04C

ALIGN

8' - 0"

PT-5

PT-6

PT-5

PT-5

PT-6E

PT-6

PT-6

PT-6E PT-6E

PT-6E

PT-6E

PT-5

4 7/8"

7' - 10"

9.25

9.20A

7' - 6"

6.36

6.36

6.36

6.366.36

6.36

6.36

6.36

6.366.36

6.36

KEY PLAN

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

SCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

CEILING ACCESS PANEL

2X4 FLUORESCENT FIXTURE

2X2 FLUORESCENT FIXTURE

CEILING HEIGHT

RECESSED CAN FIXTURE

RETURN AIR GRILLE

SUPPLY AIR GRILLE

X'-X"

WIRELESS ACCESS POINT

AT ANTENNA

DOME LIGHT

AC ACCESS CONTROLLED DOOR

D

F HORN/ STROBE

TV ROUGH-IN TELEVISION OUTLET

SECURITY CAMERAC

CEILING SPEAKERS

EXIT SIGN

NOTE

A. REFERENCE MECHANICAL & ELECTRICAL DRAWINGS FOR SYMBOLS NOT SHOWN HERE.

RCP SYMBOLS & MATERIALS LEGEND

GYPSUM CEILING

(GWB)

2X2 SUSPENDED

ACOUSTICAL TILE

CEILING (SAT)

2X4 SUSPENDED

ACOUSTICAL TILE

CEILING (SAT)

X.XX KEYNOTE - SEE SCHEDULE

OR

RECESSED LINEAR LIGHT

VANITY LIGHTOR

OR

OR

OR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

(402) 991-5520

NATHAN BOWMAN (MECH & PUMB)

MAY ALEXANDER (ELEC)

BSE ENGINEERS

11320 WEST 79TH STREET

LENEXA, KS 66214

(913) 492-7400

KEVIN BOEHRINGER (STRUCT)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

2_ M ar io n V

A _R en ov at e

3B _k yl ek

9D U

H U

.rv t

9/

/2

:4 8:

A

M

AE112

REFLECTED CEILING PLAN - 3RD LEVEL -

AREA B

STONE / HFG ARCHITECTURE

600 EAST 7TH ST & 330 N. MEAD

SIOUX FALLS, SD 57103 & WICHITA, KS 67202

(605) 271-1144 & (316) 262-2500

BEAU FEY (ARCH) & WAYNE BONGARTZ (PM)

RENOVATE PATIENT WARD 3B

FOR PATIENT PRIVACY AND

INTENSIVE CARE

MARION IL

BLDG #001

WESLEY PINKS

09/20/2024 BF/WB/SS KK/AB/AW

SGA #231942

VA #657A5-23-110

FINAL BID DOCUMENTS

ARCH SHEET: 6 OF 26

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.10A EXISTING EXPANSION JOINT. FLOOR AND ROOF STRUCTURE ASSEMBLY TO REMAIN AS IS.

DAMAGED SEALANT AND/OR MORTAR EXPOSED BY CONSTRUCTION TO BE PATCHED OR

REPLACED. NEW CEILING AND/OR WALL ASSEMBLIES AT JOINT TO BE CONSTRUCTED

ACCORDING TO PROVIDED DETAILS.

6.36 VERTICAL GWB EXPANSION JOINT.

8.04C 2X2 CEILING MOUNTED ACCESS PANEL

9.20A 5/8" GYPSUM BOARD, TYPE "C"

9.21 SUSPENDED CEILING TILE - SEE RCP.

9.25 GWB SOFFIT WALL - SEE DETAILS.

9.26 GWB & MTL STUD CEILING - SEE RCP.

10.36 WINDOW ROLLER SHADE - SEE SCHEDULE.

10.37 RESIN PANEL - SEE AI SHEETS.

1/4" = 1'-0" D5

REFLECTED CEILING PLAN - 3RD LEVEL - AREA B

PROCEEDING WITH THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. PROVIDE SEALANT AT ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS, TRANSITIONS, AND ACCORDING TO INDUSTRY STANDARDS AND MANUFACTURER'S SPECIFICATIONS.

D. CONTRACTOR MUST PROVIDE PROTECTION FOR ROOF MEMBRANE & RELATED COMPONENTS DURING

ALL PHASES OF ROOF & PENTHOUSE CONSTRUCTION.

E. ANY DAMAGE TO THE EXISTING ROOF MEMBRANE, CAUSED BY OR DISCOVERED DURING

CONSTRUCTION, MUST BE IMMEDIATELY COMMUNICATED TO THE OWNER & ARCHITECT.

F. FASTEN PENTHOUSE GUARDRAILS TO EXTERIOR FACE OF EXISTING PENTHOUSE.

GENERAL ROOF NOTES

AA

RR

BB

DD

EE

GG

MM

KK

JJ

HH

FF

17151211109743

5 8 13 16

CC

8'

-6

232'-6"

8'

-6

'-6

'-8

8' -6

'-8

'-8

'-0

'-1

0" 9'

-2

'-6

16'-0 1/2" 20'-5 1/2" 24'-9" 110'-0" 24'-9" 20'-5 1/2" 16'-0 1/2"

'-6

'-8

8' -6

'-8

'-8

'-0

'-1

0" 9'

-2

'-6

16'-0 1/2" 20'-5 1/2" 10'-7" 10'-9" 10'-9" 9'-11" 20'-0" 11'-8" 12'-2" 11'-8" 20'-0" 9'-11" 10'-9" 10'-9" 10'-7" 20'-5 1/2" 16'-0 1/2"

'-3

8'

-3

'-3

8'

-3

5' -0

5' -0

'-6

'-6

'-6

9'

-2

'-6

'-6

9'

-2

'-6

'-6

9'

-2

'-6

B6

AE301

B2

AE301

D6

AE301

1.03

1.03

1.03

1.03

1.03

1.03

1.03

1.03

23.01

23.01

23.01

23.01

ADJACENT BUILDING

5.41

2'-6" 10'-0" 2'-6" 2'-6"

A P

X

'-5

/8

'-0

1.03

5.43B

5.43B

APX GUARDRAIL LENGTH

21'-8 1/2"

A P

X G

U A

R D

R A

IL

L

E N

G T

H

'-4

/8

A P

X G

U A

R D

R A

IL

L

E N

G T

H

'-4

/8

5.43B

5.43B

5.43B

5.43B

8'-0" 6'-0"

3'-0"

5.43B

5.43B

5.43B

5.43B

5.43B

5.43B

KEY PLAN

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

SCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

(402) 991-5520

NATHAN BOWMAN (MECH & PUMB)

MAY ALEXANDER (ELEC)

BSE ENGINEERS

11320 WEST 79TH STREET

LENEXA, KS 66214

(913) 492-7400

KEVIN BOEHRINGER (STRUCT)

C :\U se rs

\K .K ue pe r\D oc um en ts \2

2_ M ar io n V

A _R en ov at e

3B _k yl ek

9D U

H U

.rv t

9/

/2

:4 8:

A

M

AE130

ARCHITECTURAL ROOF PLAN - OVERALL

STONE / HFG ARCHITECTURE

600 EAST 7TH ST & 330 N. MEAD

SIOUX FALLS, SD 57103 & WICHITA, KS 67202

(605) 271-1144 & (316) 262-2500

BEAU FEY (ARCH) & WAYNE BONGARTZ (PM)

RENOVATE PATIENT WARD 3B

FOR PATIENT PRIVACY AND

INTENSIVE CARE

MARION IL

BLDG #001

WESLEY PINKS

09/20/2024 BF/WB/SS KK/AB/AW

SGA #231942

VA #657A5-23-110

FINAL BID DOCUMENTS

ARCH SHEET: 7 OF 26

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.03 2X2 ROOF WALKPADS

5.41 PAINTED METAL LADDER.

5.43B 3'-6" HIGH PAINTED METAL GUARDRAIL. HORIZONTAL RAILS TO BE POSITIONED AT 1'-0" INCREMENTS FROM THE TOP RAIL. RAILS & BALUSTERS TO BE A MINIMUM OF 1 1/2" IN DIAMETER.

COLOR TO MATCH NEWEST EXISTING GUARDRAILS AT SURROUNDING ROOF/PENTHOUSES.

23.01 MECH ELEMENT - SEE MECH.

1/8" = 1'-0" D5

ROOF PLAN - OVERALL

PROCEEDING WITH THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. FREE-STANDING FURNITURE IS PROVIDED AND INSTALLED BY OTHERS.

D. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

E. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.

F. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.

G. DETAILS SHOWN ARE TYPICAL UON. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.

H. PROVIDE BACKING FOR ALL TOILET ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED TO

BUILDING WALLS.

I. INSTALL BLOCKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING,

MARKERBOARDS, WALL MOUNTED MONITORS/TVS, COUNTERTOP SUPPORTS, ETC.

J. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD.

K. PROVIDE CONTROL JOINTS IN DRYWALL EVERY 30'-0".

L. ALL DIMENSIONS ARE TO OUTSIDE OF WALL FRAMING.

M. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

N. SEE SHEET AE601, ARCHITECTURAL SCHEDULES & ASSEMBLIES, FOR MORE INFORMATION

REGARDING DOORS, WINDOWS, AND WALL TYPES.

O. CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY EXISTING STRUCTURAL MEMBERS WHICH MAY

CONFLICT WITH THE DESIGNED WALL LAYOUT AND/OR DESIGNED PLUMBING LOCATIONS BEFORE ANY

WALLS ARE CONSTRUCTED.

P. CONTRACTOR TO NOTIFY ARCHITECT OF LOCATIONS WHERE PENETRATIONS IN THE FLOOR MAY INTERSECT AND/OR INTERFERE WITH THE INTERGITY OF EXISTING CONCRETE JOISTS. WHERE MEP SYSTEMS CANNOT BE EASILY REROUTED WITHIN ALREADY DESIGNED WALLS, CEILINGS, OR CHASES, THE A/E TEAM WILL REVISE AND REISSUE DRAWINGS SO AS TO AVOID CONFLICTS WITH THE EXISTING

JOISTS.

GENERAL PLAN NOTESSCOPE OF CONSTRUCTION LEGEND

AREA NOT WITHIN CONSTRUCTION BOUNDARIES

EXISTING COMPONENTS

NEW COMPONENTS

A

R

BDEGK J H C

B6

AE301

D6

AE301

NA

CANOPY

S202-01

STAIR

2' -6

'-6

2' -6

2'-6" 2'-6"

A P

X

4' -0

/2

5'

-0

2' -6

'-6

2' -6

APX

8'-3"2'-6"15'-0"2'-6"

APX

6'-0" 35'-0" 2'-6"

A P

X

'-0

2'

-6

2'-6" 15'-0" 2'-6"

1.03 1.03

1.03

1.03

1.03

1.03

1.03

23.01

23.01

23.01

23.01

23.01

A P

X

1' -1

0" 2'

-6

2' -6

NA

EAST

PENTHOUSE

1.03

1.03

1.03

APX

3'-8"

APX

4'-8"

A P

X

4' -9

/4

APX

4'-7 1/2"

A P

X

4' -8

2'-6"

5.41 1'-3"1'-3"

3'-0" 8'-0"

B1

AE131

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE

PROCEEDING WITH THE WORK.

B. SOME SPECIFIED PRODUCTS MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY

RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.

C. PROVIDE SEALANT AT ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS, TRANSITIONS, AND ACCORDING TO INDUSTRY STANDARDS AND MANUFACTURER'S SPECIFICATIONS.

D. CONTRACTOR MUST PROVIDE PROTECTION FOR ROOF MEMBRANE & RELATED COMPONENTS DURING

ALL PHASES OF ROOF & PENTHOUSE CONSTRUCTION.

E. ANY DAMAGE TO THE EXISTING ROOF MEMBRANE, CAUSED BY OR DISCOVERED DURING

CONSTRUCTION, MUST BE IMMEDIATELY COMMUNICATED TO THE OWNER & ARCHITECT.

F. FASTEN PENTHOUSE GUARDRAILS TO EXTERIOR FACE OF EXISTING PENTHOUSE.

GENERAL ROOF NOTES

KEY PLAN

AREA

A

AREA

E

AREA

B

AREA

D

AREA

C

NORTH

T.O. 3RD LEVEL ROOF

149'-2"

S

ID

E R

A

IL

E X

T E

N S

IO

N

3' -6

'-0

1' -0

1'

-0

1' -0

1'

-0

1' -0

1'

-0

1' -0

1'

-0

1' -0

1'

-0

5.41

1.03

ALIGN TOP LADDER RUNG

WITH TOP OF ADJACENT

EXISTING ROOF SURFACE

3"

3"

APX

5 1/2"

A P

X

'-3

/4

/D5 AE131

1.14A

1.14C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

A

B

C

D

2 4 5

Phase

DESIGNER OF RECORD

A/E:

STAMPCONSULTANTS

MEP: STRUCTURAL:

6"

6"

6"

6"

O N

E E

IG

H

T H

I N

C H

O

N E

F O

O T

1/

8"

'-0

O

N E

Q U

A R

T E

R I

N C

H

O N

E F

O O

T

1/ 4"

'-0

T H

R E

E E

IG

H

T H

S

IN

C H

O

N E

F O

O T

(3 /8

1' -0

O

N E

H A

LF

I

N C

H

O N

E F

O O

T

1/ 2"

'-0

T H

R E

E Q

U A

R T

E R

S

IN

C H

O

N E

F O

O T

3/

4"

'-0

O

N E

I N

C H

O

N E

F O

O T

1"

'-0

O N

E A

N D

O N

E H

A

LF

I N

C H

E S

O

N E

F O

O T

1/ 2"

'-0

T H

R E

E

IN

C H

E S

O

N E

F O

O T

3"

'-0

32 4 5 61

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMA…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .