M. RELOC OnePass System Drops - Drop Cable (Basis of Design).pdf

PDF 557 KB Posted

Attached to
C3 Interior LED Lighting
Solicitation number
15F06723Q0000316
Issued by

About this file

This document provides product specifications for OnePass System Drops, which are plug-in connections for industrial fixtures and miscellaneous devices. The OnePass System includes Circuit Selectors, Cord Unselectables, and Drop Cables in various configurations. Circuit Selectors allow alternating energization of fixtures between phases. Cord Unselectables are used when additional conductors or circuits are needed. Drop Cables provide power from the branch circuit to fixtures and devices. Products are offered in voltage options from 120V to 480V, with conductor gauges of 12AWG or 18AWG insulation rated from -20°C to 90°C. Configurations include standard wiring and options like extreme temperature rating, isolated ground wires, and integrated low voltage and line voltage conductors. Product listings and approvals are noted. Dimensions and wiring diagrams are provided.

View the file

Other files

File Type Posted
Questions - Answers.xlsx XLSX spreadsheet
Amendment One SF30.pdf PDF
K. RELOC OnePass Cables - Fixture Cable - OFC Series (Basic of Design).pdf PDF
A. BLTR -1x4 Relight LED Light Fixture (Basis of Design).pdf PDF
S. nLight System - Occupancy Sensor (Basis of Design).pdf PDF
D. CJIS Existing Supporting Rooms Light Fixture – F3.pdf PDF
23-0801_Brand Name or Equal for Solicitation.pdf PDF
N. RELOC External Connector - RCAT5.pdf PDF
J. RELOC OnePass Cables - Cable - OC1 Series (Basic of Design).pdf PDF
T. nLight System - Wallpod On & Off Control (Basis of Design).pdf PDF
C. Photometric Analysis with 2BLT2 Light Fixture (Basis of Design).pdf PDF
U. nLight System - Wallpod Scene Control (Basis of Design).pdf PDF
G. Support Rooms Light Fixture Drawing PDF - Please Request DWG File.pdf PDF
23-0830 C3 LED LGT Control Materials List.xlsx XLSX spreadsheet
O. RELOC Distribution Box Primary (Basis of Design).pdf PDF
E. New Support RM 48-inch LED Strip Light Fixture (Basis of Design).pdf PDF
Q. nLight System - Eclypse Controller (Basis of Design).pdf PDF
15F06723Q0000316 - RFQ.pdf PDF
B. BLT -2x2 LED Light Fixture (Basis of Design).pdf PDF
V. nLight System - Unitouch Touch Screen Wall Switch (Basis of Design).pdf PDF
R. nLight System - 8-Port Bridge (Basis of Design).pdf PDF
L. RELOC OnePass Splitter Splice - OSS Series (Basis of Design).pdf PDF
I. RELOC OnePass Convertor - OC Series (Basis of Design).pdf PDF
F. Photometric Analysis of Support Rooms with Basis of Design Light Fixture.pdf PDF
P. RELOC Rectangular Floor Module.pdf PDF
H. RELOC RRL Universal Fixture Connector for Basis of Design.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OCS_OCU_OD

Catalog Number

Notes Type

One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com © 1996-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/27/23

FEATURES & SPECIFICATIONS

INTENDED USE

The OnePass Circuit Selector (OCS), Cord Unselectable (OCU), and Drop Cable (OD) are plug-in connections for industrial fixtures. The OD, OCU and OCS can be prewired by fixture manufacturer or field installed. In addition to industrial applications, the OD also allows miscellaneous devices such as exits, emergency units, convenience power, access floor systems and commercial lighting applications to become part of the OnePass system to be field installed by the contractor.

The OCU should be used when applications require:

• 5 conductors are required to drop to lighting fixtures.

• A “TAP22N” or “TAP122N” option is required to drop to lighting fixture.

• A “TAP34” is required for circuit two in a 208V, 240V or 480V 2 circuit design.

ELECTRICAL

• Rated for use on 20-amp branch circuits.

• 18 AWG rubberized cord rated for 600V, 105°C temperature containing a fully rated ground conductor.

• The OCS molded circuit identifier denotes position of each conductor.

• Safety-keying prevents accidental mating of components with different voltages.

• The OD conductors are 12AWG and 18AWG copper conductors with -20°C to +90°C thermoplastic insulation rated 600V.

• C12S option includes three 12AWG or 18AWG conductors and two 18AWG shielded conductors for controls wiring. (-20°C to +90°C)

SYSTEM FEATURES

• Pin and socket contacts.

• Color-coded labels for quick voltage identification.

• EXT option enables OD’s to be installed in hot and cold applications (-40° to 90°C). Type of insulation for EXT option is based on NEC Table 310.104(A).

• Dust Cover available for unused ports: RDC3 METAL DUST COVER CSA/UL J50 (available job pack of 50 only).

• Low voltage cable plenumn rated.

LISTINGS

• C-UL-US listed for indoor, dry, and accessible locations.

• Meets or exceed all the requirements of UL183 and NEC (NFPA70) Article 604 for manufactured wiring systems.

• C12S option meets NEC requirements for separation of Class 2 and Class 3 circuits from Class 1 circuits by a barrier as defined by Article 725.136(B).

• Canadian Patent No. 2,845,603 (Class l, Class ll).

• Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities

(HCF option).

BUY AMERICAN ACT

This product is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations.

Please refer to www.acuitybrands.com/resources/buy-american for additional information.

WARRANTY

5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/ warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application.

Specifications subject to change without notice.

OnePass® System Drops

OCS

Circuit Selector

OCU

Cord Unselectable

OD

Drop Cable mailto:techsupportreloc%40acuitybrands.com?subject= http://www.relocwiring.com https://www.acuitybrands.com/resources/buy-american http://www.acuitybrands.com/support/warranty/terms-and-conditions http://www.acuitybrands.com/support/warranty/terms-and-conditions

OnePass® System Drops

One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com © 1996-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/27/23

‡ Option Value Ordering Restrictions & Notes

Option value Restriction 120, 277, 347 For 2 neutral applications, order OCU with TAP22N to tap the second hot and neutral.

18/3G When ordered with 120 or 277 or 347 volts, two selector switches will be provided for selection of any 2 of the 3 tap positions available.

Connector Type NEMA receptacles available with three 18AWG conductors only.

For 208, 240 and 480 Volts Single circuit or 3 phase applications with 208 or 240 or 480 volts have two selector switches for selecting any 2 of the 3 tap positions. For two circuit 208 or 240 or 480 volt applications, order OCU with TAP34 to tap the second circuit.

OCS For ordering attached to an Acuity Brands lighting fixture, simply move the voltage before the ballast description and remove all other spaces from the OCS catalog number (see examples above).

RRL For use with fixtures. Fixture must have RRL and wiring instruction installed to use this option. See fixture spec sheet for details and availability. See RRL spec sheet for connector details.

Series Voltage Conductors Length Modular Plug Connector Type‡ Device Color

OCS‡ 120 120V‡

208 208V 240 240V 277 277V‡ 347 347V‡ 480 480V

For 120, 277 and 347 Volts (blank) Three 18 AWG conductors, including ground 18/3G Four 18 AWG conductors, including ground‡ For 208, 240 and 480 Volts‡ (blank) Four 18 AWG conductors, including ground

(blank) 6ft.

10 10ft.

15 15ft.

20 20ft.

25 25ft.

30 30ft.

35 35ft.

40 40ft.

45 45ft.

50 50ft.

RRL RELOC®-ready luminaires ‡ (blank) Not required

L515 120V- NEMA L5 - 15R

L520 120V - NEMA L5 - 20R

L715 277V - NEMA L7 - 15R

L720 277V - NEMA L7 - 20R

L615 208V - NEMA L6 - 15R

L620 208V - NEMA L6 - 20R

L820 480V - NEMA L8 - 20R

(blank) White

ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OCS 120 18/3G 10

Examples

Ships Separately (Field Installation)

Ships Attached (Factory Installation) Fixture w/o RELOC Fixture with RELOC

OCS 277 OCS IBZ 454L GEB10PS9O IBZ 454L 277 GEB10PS90 OCS

OCS 120 18/3G 10 OCS4C10 IBZ 454L GEB10PS9O IBZ 454L 120 GEB10PS90 EL14 0CS4C10

mailto:techsupportreloc%40acuitybrands.com?subject= http://www.relocwiring.com https://www.acuitybrands.com/products/detail/248102/reloc/rrl/reloc-ready-connector https://www.acuitybrands.com/products/detail/248102/reloc/rrl/reloc-ready-connector

OnePass® System Drops

One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com © 1996-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/27/23

Series Voltage Tap Position‡ Length Modular Plug Plug Type Controls Wiring Device Color

OCU ‡ 120 120V

208 208V 240 240V 277 277V 347 347V2

480 480V

For 120, 277 and 347 Volts ‡ TAPG1N 1 hot, with ground and neutral‡ TAP22N 1 hot, Tap position 2 with second neutral only ‡

TAP122N 2 hots, Tap position 1 and 2 with first and second neutrals‡

TAP123 3 hots, Tap positions 1, 2, 3

For 208, 240 and 480 Volts TAPG12 2 hot, with ground‡ TAP12 2 hots, Tap positions

1 & 2 TAP34 2 hots, Tap positions

3 & 4 TAP1234 4 hots, Tap positions

1,2,3 & 4

(blank) 6ft.

10 10ft.

15 15ft.

20 20ft.

25 25ft.

30 30ft.

35 35ft.

40 40ft.

45 45ft.

50 50ft.

RRL RELOC®-ready luminaires ‡

(blank) Not required

L615 208V- NEMA L6 - 15R9

L620 208V - NEMA L6 - 20R9

L820 480V - NEMA L8 - 20R9

(blank) Not required C12S Integrated

CI,CII rated line voltage and signal wires

(blank) White

ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OCU 277 TAPG1N 15 C12S

Examples

Ships Separately (Field Installation)

Ships Attached (Factory Installation) Fixture w/o RELOC Fixture with RELOC

OCU 277 TAP122N 15 OCU122N15 IBZ 454L GEB10PS90 IBZ 454L 277 GEB10PS90 OCU122N15

OCU 480 TAP34 BK OCU34BK IBZ 454L HVOLT GEB10PS9O IBZ 454L 480 GEB10PS90 OCU34BK

‡ Option Value Ordering Restrictions & Notes

Option value Restriction For 120, 277 and 347 Volts To match existing OCU with TAP1, TAP2, TAP3, TAP12, TAP13, TAP23 refer to OCS ordering information for Three 18 AWG conductors.

L615, L620, L820 208V and 480V NEMA plugs available with TAP12 and TAP34. Other configurations, such as 3-phase 208, 240 and 480V circuits are available with OCS. 120V & 277V NEMA plugs available with OCS.

OCU For ordering attached to an Acuity Brands lighting fixture, simply move the voltage before the ballast description and remove all other spaces from the OCU catalog number (see examples above ). Order OCU instead of OCS when one of these three conditions arise: five conductors are required to drop to the fixture, a second neutral is required in the fixture, or hot conductors in position 3 and 4 need to be tapped (The second circuit in a 208, 240, or 480 volt application).

RRL If RRL selected, fixture must have RRL and wiring instruction. See fixture spec sheet for details. See RRL spec sheet for connector details.

Tap Position Tap position indicates the hot conductors pin position. See wire color charts on page 5.

TAP12 Available with C12S option and 208 or 240 or 480 volts.

TAP22N, TAP122N Each configuration of TAP22N and TAP122N requires “12/4G 2N” or “10/4G 2N” OnePass® components to complete the two neutral system.

TAPG1N Available with C12S and 120 or 277 or 347 volts.

mailto:techsupportreloc%40acuitybrands.com?subject= http://www.relocwiring.com https://www.acuitybrands.com/products/detail/248102/reloc/rrl/reloc-ready-connector

OnePass® System Drops

One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com © 1996-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/27/23

Series Voltage Conductors Length Modular Plug

OD 120 120V

208 208V 240 240V 277 277V 347 347V 480 480V

12/2G Three 12 AWG conductors, including one 12 AWG ground

12/3G Four 12 AWG conductors, including one 12 AWG ground

12/4G Five 12 AWG conductors, including one 12 AWG ground

18/2G Three 18 AWG conductors, including one 18 AWG ground ‡

18/3G Four 18 AWG conductors, including one 18 AWG ground ‡

18/4G Five 18 AWG conductors, including one 18 AWG ground ‡

01 ft up to 50 ft (blank) Not required RRL RELOC®-ready luminaires ‡

ORDERING INFORMATION For shortest lead times configure product using bolded options. Example: OD 277 12/4G 15

Controls Wiring Options Device Color

(blank) Not required

C12S Integrated CI,CII rated line voltage and signal wires ‡

(blank) Not required

2N Two circuit, two neutral ‡

EXT Extreme temperature rating conductors ‡

HCF Meets healthcare facility requirements ‡

IGW Isolated ground wire ‡

CSA Required when ordered for Canada ‡

(blank) Not required

RD Red ‡

‡ Option Value Ordering Restrictions & Notes

Option value Restriction 18/2G, 18/3G, 18/4G Available in lengths up to 10ft only. For longer lengths please select an alternative gauge wiring option.

2N Available with 120 or 277 or 347 volts and 10/4G or 12/4G or 18/4G conductors only.

C12S Available with 12/G or 18/2G conductors only.

CSA Product label for fixture drops must state: “Not for interruption of current” when ordered for Canada.

EXT Required for EXTREME hot and cold temperature applications (-40° to 90°C). Not available with 10/4G or 12/4G or 18/2G or 18/3G or 18/4G conductors.

HCF Available with 12/4G conductors only. Not available with C12S controls wiring.

IGW Available with 120 volts and 12/3G or 12/4G conductors only in lengths up to 35ft.

RD Non-plenum rated. Available up to 35ft only.

RRL Available with 18 gauge conductors only. For use with fixtures. Fixture must have RRL and wiring instruction installed to use this option. See fixture spec sheet for details and availability. See RRL spec sheet for connector details.

mailto:techsupportreloc%40acuitybrands.com?subject= http://www.relocwiring.com

OnePass® System Drops

One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com © 1996-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/27/23

DIMENSIONS

Dimensions are shown in inches (millimeters) OCS - Circuit Selector

A – Injection molded, high-impact polymeric compound enclosure B – Tin-plated, brass contacts C – Rubberized cord with 18 AWG conductors, rated at 600V, 105°C and containing a fully rated ground conductor

3-1/16 (77.8)

2-1/4 (57.2)

B

C

A

POSITION 1

PHASE A PHASE B PHASE C

POSITION 2 POSITION 3

OCS Application for 208, 240, 480 and 18/3G Option for 120V, 277V and 347V Systems A 3-phase run from a hardwire drawing is shown below. The three OCS connector views show how fixtures can be energized alternating between the three phases on a run by placing the OCS selector switch into position 1-2, 1-3 or 2-3.

OCS Application for 120V, 277V and 347V Systems A 3-phase run from a hardwire drawing is shown below. The three OCS connector views show how fixtures can be energized alternating between the phases on a run by placing the OCS selector switch into position 1, 2 or 3.

POSITION 1-2

PHASE A-B PHASE A-C PHASE B-C

POSITION 1-3 POSITION 2-3

Note: OCS cannot be used for the second circuit (tap 34) in a 208/240/480V application. See OCU.Note: OCS cannot be used for the second circuit (tap 34) in a 208/240/480V application. See OCU.

3-1/4 (82.5)

A

C

D

B

2-1/4 (57.2)

DIMENSIONS

Dimensions are shown in inches (millimeters) OCU - Circuit Unselectable

A – Connector body B – 18-gauge galvanized steel cover, zinc alloyed casting C – Tin-plated, brass contacts D – Rubberized cord with No. 18 AWG.

mailto:techsupportreloc%40acuitybrands.com?subject= http://www.relocwiring.com

OnePass® System Drops

One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com © 1996-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/27/23

OCS and OCU Wire Color Chart OCS Cord 120V, 277V, 347V Standard Wire Colors

Position 1 2 3 4 5 Conductor Ground Hot #1 Hot #2 Hot #3 Neutral #1

277V Green Black White 277V (18/3G) Green Black/Red White

120V/347V (18/3G) Green Black/Red White OCS Cord 208V, 240V, 480V Standard Wire Colors

Position 1 2 3 4 5 Conductor Ground Hot #1 Hot #2 Hot #3 Hot #4

208V/240V/480V Green Black/ Red OCU Cord 120V, 277V, 347V Standard Wire Colors

Position 1 2 3 4 5 Conductor Ground TAP1 (Hot #1) TAP2 (Hot #2) TAP3 (Hot #3) Neutral #1

TAP123 Green Black Red Orange White OCU Cord 208V, 240V, 480V Standard Wire Colors

Position 1 2 3 4 5 Conductor Ground TAP1 (Hot #1) TAP2 (Hot #2) TAP3 (Hot #3) TAP4 (Hot #4)

TAP12 Green Black White TAP34 Green Black White

TAP1234 Green Black Red Orange White OCU Cord 120V, 277V, 347V Two Circuit, Two Neutral (2N option)

Position 1 2 3 4 5 Conductor Ground TAP1 (Hot #1) TAP2 (Hot #2) Neutral #2 Neutral #1

TAP22N Green Black White TAP122N Green Black Red Orange White

OCU Cord 120V, 277V, 347V Class I, Class II (C12S option) Position 1 2 3 4 5 Conductor Hot #1 Neutral #1 Ground Data #1 Data #2

277V (TAPG1N) Brown Gray Green Violet Pink (or Gray) 120V/347V (TAPG1N) Black White Green Violet Pink (or Gray)

OCU Cord 208V, 240V, 480V Class I, Class II (C12S option) Position 1 2 3 4 5 Conductor Hot #1 Neutral #1 Ground Data #1 Data #2

208V/240V (TAPG12) Brown Orange Green Violet Pink (or Gray) 480V (TAPG12) Brown Orange Green Violet Pink (or Gray)

OC2OC

OC2OCS/OCU/OD

OCS/OCU/OD

SYSTEM VIEW

System View designs are for illustrative purposes only.

mailto:techsupportreloc%40acuitybrands.com?subject= http://www.relocwiring.com

OnePass® System Drops

One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupportreloc@acuitybrands.com www.relocwiring.com © 1996-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/27/23

OD Wire Color Chart OD Drop Cable 120V, 277V, 347V Standard Wire Colors OD Cable 120V, 277V, 347V Class I, Class II (C12S option)

Position 1 2 3 4 5 Position 1 2 1 4 5 Conductor Ground Hot #1 Hot #2 Hot #3 Neutral #1 Conductor Hot #1 Neutral #1 Ground Data #1 Data #2

277V Bare or Green Brown Orange Yellow Gray 120V & 347V Black White Bare or Green Violet Pink (or Gray) 120V/347V Bare or Green Black Red Blue White 277V Brown Gray Bare or Green Violet Pink (or Gray)

OD Drop Cable 208V, 240V, 480V Standard Wire Colors OD Cable 208V, 240V, 480V Class I, Class II (C12S option) Position 1 2 3 4 5 Position 1 2 3 4 5 Conductor Ground Hot #1 Hot #2 Hot #3 Hot #4 Conductor Ground Hot #1 Hot #2 Neutral #2 Neutral #1

480V Bare or Green Brown Orange Yellow Violet 208V & 240V Brown Orange Bare or Green Violet Pink (or Gray) 208V & 240V Bare or Green Black Red Blue Violet 480V Brown Orange Bare or Green Violet Pink (or Gray)

OD Drop Cable 120V, 277V, 347V Two Circuit, Two Neutral (2N option) Position 1 2 3 4 5 Conductor Ground Hot #1 Hot #2 Neutral #2 Neutral #1

277V Bare or Green Brown Orange White Gray 120V & 347V Bare or Green Black Red Gray White

DIMENSIONS

Dimensions are shown in inches (millimeters)

A – 18-gauge galvanized steel cover, zinc alloyed casting B – Connector body C – Tin-plated, brass contacts D – .015” spring steel latches E – MC Cable standard. HCF MC, C12S MC optional. IGW option standard with FMC.

3-1/4 (82.5)

2-1/4 (57.2)

7/16 (11.2)

A

E B

D

C

OD - Drop Cable mailto:techsupportreloc%40acuitybrands.com?subject= http://www.relocwiring.com

Catalog Number 3:
Page 1:
Notes 3:
Page 1:
Type 3:
Page 1:
Text Field 41:
Text Field 42:
Text Field 43:
Text Field 44:
Text Field 45:
Text Field 46:
Text Field 47:
Text Field 16:
Text Field 17:
Text Field 18:
Text Field 19:
Text Field 20:
Text Field 21:
Text Field 22:
Text Field 32:
Text Field 23:
Text Field 24:
Text Field 25:
Text Field 26:
Text Field 27:
Text Field 28:
Text Field 29:
Text Field 30:

File details come from the government source that posted it. Updated .