This solicitation requests proposals for C3 Interior LED Lighting. The Department of Justice Federal Bureau of Investigation Headquarters Division seeks to purchase LED lighting fixtures and accessories to replace existing fluorescent fixtures in interior office spaces. Offerors should propose LED troffer fixtures, pendant mounted fixtures, wall sconces, and emergency battery backup options. Proposals are due by April 15, 2023, and the agency intends to make one award by June 30, 2023. Pricing should remain valid for 90 days. Small businesses are encouraged to compete for this total small business set-aside contract.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMERCIAL INDOOR BLTR-1X4
Catalog Number
Notes
TypeFEATURES & SPECIFICATIONS INTENDED USE — The BLTR Best-Value Low Profile LED Relight Assembly is a cost effective solution for renovating existing fluorescent troffer and parabolic fixtures while providing upgraded aesthetics and outstanding performance.
The BLTR’s popular center basket design offers a clean, versatile style, and volumetric distribution. The wide range of lumen packages and control and driver options make the BLTR a great choice for many applications including offices, schools, hospitals, retail spaces and other general lighting applications. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses.
CONSTRUCTION — Universal end brackets are constructed of 22-gauge powder-painted steel and are secured to the host fixture with provided TEKS™ screws. The driver and light engine assembly is integrated in the BTLR door assembly making this an extremely simple, time saving, relight solution. The door frame and reflector assembly is a made of cold-rolled steel and is painted after fabrication with a matte white powder paint for improved aesthetics and increased light diffusion. Diffuser trim rings provide an attractive mounting for integral sensors as well as adding a decorative element to the luminaire aesthetics.
LED boards and driver are accessible from below.
OPTICS — Volumetric illumination is achieved by creating an optimal mix of light to walls, partitions and vertical and horizontal work surfaces – rendering the interior space, objects and occupants in a more balanced, complimentary luminous environment. High performance extruded acrylic diffusers conceal LEDs and efficiently deliver light in a volumetric distribution. Four diffuser choices available - curved and square designs with linear prisms or a smooth frosted finish.
ELECTRICAL — Long-life LEDs, coupled with high-efficiency drivers, provide superior quantity and quality of illumination for extended service life. 80% LED lumen maintenance at 60,000 hours (L80/60,000). Color Variation within 3-step MacAdam ellipse (3SDCM).
Non-Configurable BLTR Relight: Generic 0-10 volt dimming driver. Dims to 10% Configurable BLTR Relight: available in High Efficiency (HE) versions for applications where a lower wattage (over the standard product) is required. High Efficiency versions deliver >130 LPW and can be specified via the Lumen Package designations in the Ordering Information below.
eldoLED driver options deliver choice of dimming range, and choices for control, while assuring flicker-free, low-current inrush, 89% efficiency and low EMI.
Step-level dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance.
Optional integrated nLight®controls make each luminaire addressable - allowing it to digitally communicate with other nLight enabled controls such as dimmers, switches, nLight AIR RIO, RES7 occupancy sensors and photo controls.
Simply connect all the nLight enabled control devices and the BLTR Relight assembly using standard Cat-5 cabling.
Unique plug-and-play convenience as devices and luminaires automatically discover each other and self-commission.
Lumen Management: Unique lumen management system (option N80) provides on board intelligence that actively manages the LED light source so that constant lumen output is maintained over the system life, preventing the energy waste created by the traditional practice of over-lighting. Driver disconnect provided where required to comply with US and Canadian codes.
Driver disconnect provided where required to comply with US and Canadian codes.
SENSOR— Integrated sensor (individual control): SensorSwitch MSD7ADCX ((Passive infrared (PIR)) or MSDPDT7ADCX ((PIR/Microphonics Dual Tech (PDT)) integrated occupancy sensor/automatic dimming photocell allows the luminaire to power off when the space is unoccupied or enough ambient light is entering the space. See page 4 for more details on the integrated sensor.
Integrated Sensor (nLight Wired Networking): This sensor is nLight-enabled, meaning it has the ability to communicate over an nLight network. When wired, using CAT-5 cabling, with other nLight-enabled sensors, power packs, or WallPods, an nLight control zone is created. Once linked to a Gateway, directly or via a Bridge, the zone becomes capable of remote status monitoring and control via SensorView software. See page 6 for the nLight sensor options.
Integrated Smart Sensor (nLight Air Wireless Platform): The rES7 sensor is nLight AIR enabled, meaning it has the ability to communicate over the wireless nLight control platform. It is available with an automatic dimming photocell, and either a digital PIR or microphonics (PDT) dual technology occupancy sensor. It pairs to other luminaires and wall switches through our mobile app, CLAIRITY™, which allows for simple sensor adjustment. See page 6 fore more details on the Integrated Smart Sensor.
Integrated Wireless Sensor (single room control): SensorSwitch VERTEX JOT or JOTVTX15 luminaire-embedded occupancy and ambient light sensor allows the luminaire to power off when the space is unoccupied or when enough ambient light is entering the space. See page 4 for more details on the integrated wireless sensor.
INSTALLATION — After existing fluorescent components are removed from the host housing, universal end brackets are secured in place with TEKS™ screws. The BLTR’s integrated driver and light engine door assembly can then be hinged to the universal end brackets and will hang in place for completion of assembly plug-in wiring. Rotate the doorframe assembly closed and pivot the cam latches to secure the doorframe in place. Suitable for damp location installations. Damp location not available with sensor versions.
LISTINGS — UL/cUL Listed for use in fluorescent light fixtures. Installing Relight assemblies per instructions will not impact existing fixture UL listing. Tested to LM80 standards.
DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.
org/QPL to confirm which versions are qualified.
BUY AMERICAN ACT — Product with the BAA option is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations.
Please refer to www.acuitybrands.com/buy-american for additional information.
WARRANTY — 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed.
Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions NOTE: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
Embed nLight controls today. Prepare for tomorrow.
User-friendly install Scalability
Enhanced energy savings Space configuration
Code compliance Future-ready
Now Tomorrow
Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.
• All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency
• This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background*
• This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background*
To learn more about A+, visit www.acuitybrands.com/aplus.
*See ordering tree for details.
BLTR Relight Series
BLT4R
1' x 4' Relight
LED
Specifications
Length: 47.8 (121.4)
Width: 11.9 (30.2)
Depth: 2.75 (6.9)
Weight: 10.25 (26)
All dimensions are inches (centimeters) unless otherwise specified.
Ordering Tree
DIGITAL NAVIGATION
nLight Platform SensorSwitch JOT Photometrics Performance Data http://www.acuitybrandslighting.com/library/ll/documents/specsheets/acrylic-polycarbonate-compatibility.pdf https://www.designlights.org/QPL https://www.designlights.org/QPL http://www.acuitybrands.com/buy-american https://www.acuitybrands.com/support/warranty/terms-and-conditions http://www.acuitybrands.com/aplus https://www.acuitybrands.com/resources/buy-american
BLT4R Volumetric Recessed Lighting 1'x4' Relight
BLTR-1X4
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23
ORDERING INFORMATION Example: BLT4R 30L ADP EZ1 LP835
BLT4R
Series Air Function Lumens2 Diffuser Voltage Driver Color temperature
BLT4R 1X4 BLTR (blank) Static (white end, two piece brackets for troffers)
A Air supply/return or to maintain black reveal (black end, two piece brackets for parabolics)1
F Drywall construction end, two piece brackets (T-grid flange removed)
Standard efficiency
(>125 LPW)
20L 2000 30L 3000 40L 4000 48L 4800 60L 6000
High efficiency3
(>130 LPW)
20LHE 2000
30LHE 3000
40LHE 4000
48LHE 4800
60LHE 6000
ADP Curved, linear prisms ADSM Curved, smooth SDP Square, linear prisms SDSM Square, smooth Diffusers w/ trim rings ADPT Curved, linear prisms ADSMT Curved, smooth SDPT Square, linear prisms SDSMT Square, smooth
(blank) MVOLT 120 120V 277 277V 347 347V4,5
EZ1 eldoLED dims to 1% (0-10 volt dimming)
GZ1 Dims to 1% (0-10V dimming) 6
GZ10 Dims to 10% (0-10V dimming) 6
SLD Step-level dimming 7
LP830 82CRI, 3000 K
LP835 82CRI, 3500 K
LP840 82CRI, 4000 K
LP850 82CRI, 5000 K
LP930 90CRI, 3000K
LP935 90CRI, 3500K
LP940 90CRI, 4000K
LP950 90CRI, 5000K
nLight Interface Control 10 Standby Mode Options nLight Wired (blank) no nLight ® interface N80 nLight with 80% lumen management N80EMG nLight with 80% lumen management. For use with generator supply EM power 8
N100 nLight without lumen management
N100EMG nLight without lumen management. For use with generator supply EM power 8 nLight Wireless (blank) no nLight ® interface NLTAIR2 nLight AIR Generation 2 enabled 9 nLight Wired (blank) No sensor control NES7 nLight™ nES 7 PIR integral occupancy sensor 11
NESPDT7 nLight™ nES PDT 7 dual technology integral occupancy control 11
NES7ADCX nLight™ nES 7 ADCX PIR integral occupancy sensor with automatic dimming photocell 11
NESPDT7ADCX nLight™ nES PDT 7 dual technology integral occupancy sensor with automatic dimming photocell 11 nLight Wireless
RES7 nLight AIR control with PIR integral occupancy sensor and automatic dimming photocell 19
RES7PDT nLight AIR control with PDT dual technology integral occupancy sensor and automatic dimming photocell 19
RIO nLight AIR radio module without sensor 19
RES7EM nLight AIR PIR integral occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection 19
RES7PDTEM nLight AIR microphonics dual technology occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection 19
RIOEM nLight AIR radio module less sensor, with UL924 Emergency Operation, via power interrupt detection 19
Individual Control MSD7ADCX PIR integral occupancy sensor with automatic dimming control photocell 12
MSDPDT7ADCX PDT integral occupancy sensor with automatic dimming control photocell 12
JOT Wireless room control with “Just One Touch” pairing 20
JOTVTX15 Wireless occupancy sensor with “Just One Touch” pairing 20
NOC Occupancy sensor disabled13
BDP Disconnect Plug EL7L 700 lumen battery pack14
EL14L 1400 lumen battery pack15
E10WLCP EM Self-Diagnostic battery pack, 10W Constant Power, Certified in CA Title 20
MAEDBS14
BGTD Bodine Generator Transfer Device16
GLR Fast-blowing fuse17
GMF Slow-blowing fuse17
NPLT Narrow pallet FAO Field adjustable output18
BAA Buy America(n) Act Compliant
A+ Capable options indicated by this color background.
Notes 1 Consult factory for airflow data.
2 Approximate lumen output.
3 All versions may not achieve 130+ LPW. Refer to photometry on www.acuitybrands.com.
4 Not available with EL7L or EL14L battery packs.
5 347 not available with SLD.
6 GZ1, GZ10 not available with any Control or Sensor options.
7 Not available with N80, N80EMG, N100, N100EMG, NLTAIR2, or occupancy control.
8 nLight EMG option requires a connection to existing nLight network. Power is provided from a separate N80 or N100 enabled fixture.
9 Must order with RES7, RES7PDT, or RIO sensor. Only available with EZ1 driver.
10 Must specify diffuser with trim rings. See sensor options on page 4.
11 Requires N80, N80EMG, N100, or N100EMG.
12 Only available with EZ1 driver option. 0-10v dimming wires not accessible via access plate. Not available with Controls options.
13 Can only be ordered in conjunction with EZ1, NLTAIR2, RES7/ RES7PDT. Occupancy sensor disabled at factory but can be re-enabled upon commissioning.
14 Not available in 60L or 60LHE.
15 Not available in 48L, 60L, 48LHE, or 60LHE.
16 Requires BSE labeling. Consult factory for options.
17 Must specify voltage, 120 or 277 with GLR & GMF fusing.
18 Consult factory.
19 See UL924 Sequence of Operation information on page 3. When combined with the EZ1 option, can be used as a normal power sensing device for nLight AIR devices and luminaires with EM emergency options.
20 Wired 0-10v dimming control not available. Not available with nLight Interface or Controls options. Not available with NOC, SLD, BGTD, or FAO. Must specify diffuser with trim rings.
Lead times will vary depending on options selected. Consult with your sales representative.
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data http://www.lithonia.com http://www.acuitybrands.com
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23
Non-Configurable BLTR
Accessories & Replacement Parts Fit & Compatibility
Multiple Diffuser Options
Square Ribbed Square SmoothCurved Ribbed
ADP ADSM SDP SDSM
Curved Smooth
Non-Configurable BLTR
Stock Catalog Description* UPC Lumens Wattage LPW Color Temperature Voltage Pallet Qty Stock BLT4R 40L ADP LP835 190887551013 4072 33 123 3500K/80 CRI 120-277 30
BLT4R 40L ADP LP840 190887551082 4076 33 123 4000K/80 CRI 120-277 30
Replacement Parts: Order as separate catalog number.
DBLTR48 ADP LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 SDP LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 ADSM LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 SDSM LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 ADPT LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 SDPT LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 ADSMT LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 SDSMT LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 ADPT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 SDPT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 ADSMT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included) DBLTR48 SDSMT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included) U10528A 4 ft. replacement troffer trim strip RK8BDP 2P U Disconnect Plug (BDP), 2 Pole, Package of 1 RK8BDP 3P U Disconnect Plug (BDP), 3 Pole, Package of 1 RK8BDP 2P J10 Disconnect Plug (BDP), 2 Pole, Package of 10 RK8BDP 2P J40 Disconnect Plug (BDP), 2 Pole, Package of 40
0.75
6.0
9.5
3.75
12.0
1x4
The BLT4R Relight Assembly was designed to upgrade recessed 1x4 fixtures, including most parabolic and lensed troffers from all major manufacturers. Dimensional requirements are below, but Lithonia Lighting recommends a trial installation prior to purchasing project quantities.
SIDE SECTION
46.2
46.7
UL924 Sequence of Operation
The below information applies to all nLight AIR devices with an EM option.
• EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds.
• Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts.
• Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing.
Emergency Battery Pack Options - Field Installable
All the above are UL Listed products that are certified for field install external/remote to the fixture.
*Minimum delivered lumen output to assist in product selection for increased fixture mounting height.
The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast.
Please contact us at productsupportemergency@acuitybrands.com for any Emergency Battery related questions.
Battery Model Number Wattage Runtime
(Minutes) Lumen Output*
@ 120 Lumens/Watt Other
ILB CP07 2H A 7W 120 840 Storm Shelter / 2 Hour Runtime
ILB CP10 A 10W 90 1200
ILBLP CP10 HE SD A 10W 90 1200 Title 20, Self Diagnostic ILBLP CP15 HE SD A 15W 90 1800 Title 20, Self Diagnostic ILB CP20 HE A 20W 90 2400 Title 20 ILB CP20 HE SD A 20W 90 2400 Title 20, Self Diagnostic
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data mailto:productsupportemergency%40acuitybrands.com?subject=
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23
1. Power: Install JOT enabled fixtures and controls as instructed.
2. Pair: Insert the pairing tool into the pinhole on the wall switch; press and hold any button for 6 seconds.
3. Play: Once paired, each fixture will individually dim down to 10% brightness. All products will be fully functional.
BLTR Series
SensorSwitch
WSXA JOT
SensorSwitch JOT Enabled Wireless Solution Designed with contractors in mind, the SensorSwitch JOT enabled wireless solution offers a straightforward approach to the installation and pairing of lighting fixtures and controls. Absolutely no 0-10V control wires and no mobile apps are needed with JOT enabled products, allowing for lightning speed installation right out of the box.
BLTR Series with integrated
JOT OCC
Sensors
SensorSwitch
SPODMRA JOT
JOT Wireless
1. Power: Install JOT enabled fixtures and controls as instructed.
2. Pair: Insert the pairing tool into the pinhole on the wall switch; press and hold any button for 6 seconds.
3. Play: Once paired, each fixture will individually dim down to 10% brightness. All products will be fully functional.
BLTR Series
SensorSwitch
WSXA JOT
SensorSwitch JOT Enabled Wireless Solution Designed with contractors in mind, the SensorSwitch JOT enabled wireless solution offers a straightforward approach to the installation and pairing of lighting fixtures and controls. Absolutely no 0-10V control wires and no mobile apps are needed with JOT enabled products, allowing for lightning speed installation right out of the box.
BLTR Series with integrated
JOT OCC
Sensors
SensorSwitch
SPODMRA JOT
Application Guide
BLT4R — Typically used for lensed troffer installations. Assembly contains white end brackets and is supplied with white trim strips for use in closing gaps down fixture sides (installer's choice - not required).
*Note: This kit will fit in Lithonia's Avante non-air fixture.
BLT4R A — Typically used for parabolic installations with black reveal. Assembly contains black end brackets to match black reveal around host housing. Does not interfere with host housing air supply/return if present (along fixture sides)..
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23 nLight Platform nLight embedded fixtures offer: Customers get:
Manual Dimming Convenience and visual comfort for occupants
Motion Sensing and/or Daylight Harvesting Energy savings and code compliance
Fixture or Group Level Control Ability to configure lighting to the space requirements
Flexibility Ease of fixture moves, adds and changes
Wireless Wall Switch (nLight AIR Only) Ease and flexibility of placement
Astronomical and Time of Day Scheduling Energy savings and building security
Scalable Solution nLight controls to grow with your business
Future-Ready nLight platform to set foundation for future upgrades and capabilities
Simple as 1,2,3
1. Install the nLight® Wired fixtures with embedded control
2. Install the nLight Wired wall switch
3. Connect the fixtures using standard CAT5e cables and the devices will automatically discover each other and work (plug and play)
BLTR Series
CAT5e nLight Wired Networking
NH
NH NH
nLight Wired nPODMA
NHNHNH
Simple as 1,2,3
1. Install the nLight® AIR fixtures with embedded smart sensor
2. Install the wireless battery-powered wall switch
3. With CLAIRITY app, pa ir the fixtures with the wall switch and if desired, customize the sensor settings for the desired outcome
BLTR Series
Mobile DevicenLight AIR rPODBA nLight Air Wireless nLight Wired Networking
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23
Sensor Options
Option Automatic Dimming Photocell
Occupancy Sensing nLight Wired Networking nLight AIR NetworkingPIR PDT
MSD7ADCX X X
MSDPDT7ADCX X X
NES7 X X
NES7ADCX X X X
NESPDT7 X X
NESPDT7ADCX X X X
RES7 X X X
RESPDT7 X X X X
Integrated Sensor with Individual Control The MSD7ADCX PIR occupancy sensor/automatic dimming photocell is ideal for areas without obstructions and where daylight harvesting may be desired. Suggested applications include, but not limited to, hallways, corridors, storage rooms, and breakrooms or other areas where people are typically moving.
The MSDPDT7ADCX PIR/Microphonics Dual Tech occupancy sensor/automatic dimming photocell is ideal for areas with obstructions and where daylight harvesting is desired. Suggested applications include, but not limited to, open offices, private offices, classrooms, public restrooms, and conference rooms.
Sequence of Operation (nES7 and rES7 and Sensor)
MIN
LIG
HT
LE
VE
L
MAX
7.5 MIN
TIME DELAY
2.5 MIN AT
A 1% LEVEL
LIGHTS OFF LIGHTS ONLIGHTS ON
Room Unoccupied
Occupants Detected In The Space
Sensor Detects Motion
MOTION NO MOTION MOTION
SEQUENCE OF OPERATION
5.5 18
4.6 15
3.7 12
2.7 9
1.8 6
0.9 3 0 m 0 ft
0.9 3
1.8 6
2.7 9
3.7 12
4.6 15
5.5 18
9 FT Mounting
• Recommended for walking motion detection from mounting heights between 8 ft (2.44 m) and 20 ft (6.10 m)
• Initial detection of walking motion along sensor axes at distances of 2x the mounting height up to 15 ft (4.57 m) and
• 1.75x up to 20 ft (6.10 m).
• Provides 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m)
• Initial detection will occur earlier when walking across sensor’s field of view than when walking directly at sensor
Sensor Coverage Pattern Mini 360° Lens
*The presetting on the automatic dimming photocell is 5fc (NES7) and 10fc (RES7).
Sequence of Operation (MSD7 Sensor)
MIN
LIG
HT
LE
VE
L
MAX
17.5 MIN
TIME DELAY
2.5 MIN AT
A 1% LEVEL
LIGHTS OFF LIGHTS ONLIGHTS ON
Room Unoccupied
Occupants Detected In The Space
Sensor Detects Motion
MOTION NO MOTION MOTION
SEQUENCE OF OPERATION
*The presetting on the automatic dimming photocell is 5fc.
nLight AIR Wireless nLight AIR is the ideal solution for retrofit or new construction spaces where adding additional wiring can be labor intensive and nLight AIR is available with or without an integral sensor. The integrated rES7 or rES7PDT smart sensors are part of each luminaire in the nLight AIR network, which can be grouped to control multiple luminaires.
The granularity of control with the digital PIR occupancy detection and daylight sensing makes a great solution for any application.
nLight Wired Networking The nES 7 is ideal for small rooms without obstructions or areas with primarily walking motion. Ideal areas include hallways, corridors, storage rooms, and breakrooms. Additionally, the nES7ADCX includes an integrated photocell, which enables daylight harvesting controls.
For areas like restrooms, private offices, open offices, conference rooms or any space with obstructions, the nES PDT 7 dual technology sensor is recommended. The nES PDT 7 utilizes both PIR (passive infrared) and Microphonics technologies to detect occupancy. Additionally, the nESPDT7ADCX includes an integrated photocell, which enables daylight harvesting controls which is ideal for areas where windows are present.
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23 nLight® Wired Control Accessories:
Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight.
WallPod stations Model number Occupancy sensors Model number On/Off nPODMA [Color] Small motion 360°, ceiling (PIR / dual tech) nCM 9 RJB / nCM PDT 9 RJB
On/Off & raise/lower nPODMA DX [Color] Large motion 360°, ceiling (PIR / dual tech) nCM10 RJB / nCM PDT 10 RJB
Graphic touchscreen nPOD TOUCH [Color] Wall switch with raise/lower nWSX PDT LV DX [color]
Photocell controls Model number Cat-5 cable (plenum rated) Model number
Full range dimming nCM ADCX RJB 10' cable CAT5 10FT J1
30' cable CAT5 30FT J1 nLight® AIR Control Accessories:
Order as separate catalog number. Visit www.acuitybrands.com/products/ controls/nlightair.
Wall switches Model number On/Off single pole rPODBA [color] G2
On/Off two pole rPODB A2P [color] G2
On/Off & raise/lower single pole rPODBA DX [color] G2
On/Off & raise/lower two pole rPODBA 2P DX [color] G2
RCMS
Notes 1 RCMS requires low voltage power from either RPP20 DS 24V G2 or PS150.
rCMS1 Example: RCMS PDT 10 AR G2
Series / Detection Power Supply1 Occupancy Detection Lens (Required) Operating Mode Generation
RCMS nLight AIR occupancy and daylight sensor
[blank] Power Supply ordered separately
PS 150 Standard 150 mA Power Supply
[blank] PIR Detection PDT Dual Tech PIR/
Microphonics
10 Large Motion/ Extended Range 360°
9 Small Motion/ Extended Range 360°
6 High Bay 360° Lens
[BLANK] None AR Auxiliary
Relay
G2 Generation 2 compatibility
Controls Accessories
SensorSwitch
WSX
nLight WIRED nPODMA DX nLight AIR rPODBA rPODBA
Winning in Small OffiesWinning in Small Offies
BLTR fixtures with integrated rIO devices complement any small office space. Pair them with an rCMS occupancy sensor and the space now has wireless occupancy sensing and dimming capability. For additional configuration options please consult with Tech Support.
BLTR with rIOnLight WIRED
NPOD UNITOUCH
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data http://www.lithonia.com https://nlight.acuitybrands.com/ https://nlight.acuitybrands.com/ https://nlight.acuitybrands.com/ https://www.acuitybrands.com/products/detail/708905/sensor-switch/wsx-series/wall-switch-sensor https://www.acuitybrands.com/products/detail/708905/sensor-switch/wsx-series/wall-switch-sensor https://www.acuitybrands.com/products/detail/982001/nlight/npodma-family/nlightr-wired-wall-switch https://www.acuitybrands.com/products/detail/982001/nlight/npodma-family/nlightr-wired-wall-switch https://www.acuitybrands.com/products/detail/982003/nlight/rpodba-family/nlightr-air-wall-switch https://www.acuitybrands.com/products/detail/982003/nlight/rpodba-family/nlightr-air-wall-switch https://www.acuitybrands.com/products/detail/981468/nlight/nlightr-unitouch/touchscreen-wall-switch https://www.acuitybrands.com/products/detail/981468/nlight/nlightr-unitouch/touchscreen-wall-switch
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23
Enabled by the embedded nLight control, the BLT actively tracks its run-time and manages its light source such that constant lumen output is maintained over the system life. Referred to as lumen management, this feature eliminates the energy waste created by the traditional practice of over-lighting.
Constant Lumen Management
PHOTOMETRICS
0 10 20 30 40 50
THOUSAND OPERATING HOURS
0 10 20 30 40 50
THOUSAND OPERATING HOURS
POWER INPUT
LIGHT
OUTPUT
100%
80%
100%
80%
34W
27W
34W
27W
LI
G
H T
O U
TP
U
T
LI
G
H T
O U
TP
U
T
PO
W
ER
IN
PU
ER
IN
PU
T
Without Lumen Management Energy is wasted and light level is inconsistent.
POWER
INPUT
LIGHT OUTPUT
With Lumen Management Energy is saved and light level remains consistent.
Wasted Energy
Saved Energy
0 10 20 30 40 50
THOUSAND OPERATING HOURS
0 10 20 30 40 50
THOUSAND OPERATING HOURS
POWER INPUT
LIGHT
OUTPUT
100%
80%
100%
80%
34W
27W
34W
27W
LI
G
H T
O U
TP
U
T
LI
G
H T
O U
TP
U
ER
IN
PU
ER
IN
PU
T
Without Lumen Management Energy is wasted and light level is inconsistent.
POWER
INPUT
LIGHT OUTPUT
With Lumen Management Energy is saved and light level remains consistent.
Wasted Energy
Saved Energy
BLT4R 40L ADP LP835, 3975 delivered lumens
BLT4R 48L ADP LP835, 5148 delivered lumens
0° 20°
40°
60°
80°
90°
0°0°0° 90°
180°
Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10%
R C
R
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
26.3
42.7
75.3
100.0
0.0
100.0
26.3
42.7
75.3
100.0
0.0
100.0
CP Summary
0° 90
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
0° 20°
40°
60°
80°
90°
0°0°0° 90°
180°
Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10%
R C
R
Zonal Lumen Summary
Zone Lumens % Lamp % Fixture
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
26.3
42.7
75.3
100.0
0.0
100.0
26.3
42.7
75.3
100.0
0.0
100.0
CP Summary
0° 90
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
0-10 Voltage Dimmer
% Lumen Output (approximate)
% Wattage (approximate)
Step 8 Full Output 100% 100%
Step 7 9.0 VDC 98% 100%
Step 6 8.0 VDC 88% 86%
Step 5 7.0 VDC 86% 82%
Step 4 6.0 VDC 82% 80%
Step 3 5.0 VDC 76% 75%
Step 2 4.0 VDC 71% 72%
Step 1 3.0 VDC 67% 71%
FAO SETTINGS (Field Adjustable Output)
Simple adjustment of output through the use of a flat head screwdriver.
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data
COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2016-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/23
HE Performance Data
Lumen Package Lumens Input Watts LPW
20LHE ADP LP830 1836 15 126
20LHE ADP LP835 1901 15 131
20LHE ADP LP840 1931 15 133
20LHE ADP LP850 1986 15 137
30LHE ADP LP830 2856 21 134
30LHE ADP LP835 2957 21 139
30LHE ADP LP840 3004 21 141
30LHE ADP LP850 3090 21 145
40LHE ADP LP830 4009 30 135
40LHE ADP LP835 4151 30 140
40LHE ADP LP840 4217 30 142
40LHE ADP LP850 4338 30 146
48LHE ADP LP830 4463 34 130
48LHE ADP LP835 4620 34 135
48LHE ADP LP840 4694 34 137
48LHE ADP LP850 4828 34 141
60LHE ADP LP830 5655 44 129
60LHE ADP LP835 5855 44 133
60LHE ADP LP840 5948 44 135
60LHE ADP LP850 6118 44 139
Performance Data
Lumen Package Lumens Input Watts LPW
20L ADP LP830 1824 15 123
20L ADP LP835 1888 15 128
20L ADP LP840 1918 15 130
20L ADP LP850 1973 15 133
30L ADP LP830 2790 23 123
30L ADP LP835 2889 23 128
30L ADP LP840 2935 23 130
30L ADP LP850 3019 23 133
40L ADP LP830 3934 32 121
40L ADP LP835 4073 32 125
40L ADP LP840 4138 32 127
40L ADP LP850 4256 32 131
48L ADP LP830 4674 39 121
48L ADP LP835 4839 39 125
48L ADP LP840 4916 39 127
48L ADP LP850 5057 39 131
60L ADP LP830 5773 48 120
60L ADP LP835 5977 48 124
60L ADP LP840 6072 48 126
60L ADP LP850 6246 48 129
DIGITAL NAVIGATION | Home | Ordering | nLight Platform | SensorSwitch JOT | Photometrics | Performance Data http://www.lithonia.com
| Catalog Number: |
| Notes: |
| Type: |
| Air Function 2: |
| Lumens 2: |
| Diffuser 2: |
| Voltage 2: |
| Driver 2: |
| Color Temperature 2: |
| Controls 2: |
| Occupancy control 2: |
| Options 2: |
| Occupancy control 3: |
| Replacement Parts 3: |
| nLight Wired Control Accessories 3: |
| nLight AIR Control Accessories 3: |
| nLight AIR Control Accessories 4: |
| nLight AIR Control Accessories 5: |
| nLight AIR Control Accessories 6: |
| nLight AIR Control Accessories 7: |
| nLight AIR Control Accessories 8: |
| nLight AIR Control Accessories 9: |
File details come from the government source that posted it. Updated .