This document provides product specifications for the BLT-2X2 BLT Series 2' x 2' LED volumetric recessed lighting fixture. The fixture is intended for commercial indoor use and features a low-profile design, LED light engines, and a variety of configuration and accessory options. Product details include construction, optics, electrical, installation, listings, warranty and performance data. Sensor, control, and emergency options are also specified along with ordering information, mounting data, accessories, replacement parts, and photometric testing results. This lighting solution appears well-suited for the Department of Justice Federal Bureau of Investigation Headquarters Division's solicitation seeking C3 Interior LED Lighting as indicated by the related federal contract opportunity provided.

View the file

Other files

File Type Posted
Questions - Answers.xlsx XLSX spreadsheet
Amendment One SF30.pdf PDF
K. RELOC OnePass Cables - Fixture Cable - OFC Series (Basic of Design).pdf PDF
A. BLTR -1x4 Relight LED Light Fixture (Basis of Design).pdf PDF
S. nLight System - Occupancy Sensor (Basis of Design).pdf PDF
D. CJIS Existing Supporting Rooms Light Fixture – F3.pdf PDF
23-0801_Brand Name or Equal for Solicitation.pdf PDF
N. RELOC External Connector - RCAT5.pdf PDF
J. RELOC OnePass Cables - Cable - OC1 Series (Basic of Design).pdf PDF
T. nLight System - Wallpod On & Off Control (Basis of Design).pdf PDF
C. Photometric Analysis with 2BLT2 Light Fixture (Basis of Design).pdf PDF
U. nLight System - Wallpod Scene Control (Basis of Design).pdf PDF
G. Support Rooms Light Fixture Drawing PDF - Please Request DWG File.pdf PDF
23-0830 C3 LED LGT Control Materials List.xlsx XLSX spreadsheet
M. RELOC OnePass System Drops - Drop Cable (Basis of Design).pdf PDF
O. RELOC Distribution Box Primary (Basis of Design).pdf PDF
E. New Support RM 48-inch LED Strip Light Fixture (Basis of Design).pdf PDF
Q. nLight System - Eclypse Controller (Basis of Design).pdf PDF
15F06723Q0000316 - RFQ.pdf PDF
V. nLight System - Unitouch Touch Screen Wall Switch (Basis of Design).pdf PDF
R. nLight System - 8-Port Bridge (Basis of Design).pdf PDF
L. RELOC OnePass Splitter Splice - OSS Series (Basis of Design).pdf PDF
I. RELOC OnePass Convertor - OC Series (Basis of Design).pdf PDF
F. Photometric Analysis of Support Rooms with Basis of Design Light Fixture.pdf PDF
P. RELOC Rectangular Floor Module.pdf PDF
H. RELOC RRL Universal Fixture Connector for Basis of Design.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMERCIAL INDOOR BLT-2X2

BLT Series LED

2BLT2

2' x 2'

LED

Catalog Number

Notes

TypeFEATURES & SPECIFICATIONS INTENDED USE — The BLT Best-in-Value Low Profile LED luminaire features a popular center basket design that offers a clean, versatile style and volumetric distribution. High efficacy LED light engines deliver energy savings and low maintenance compared to traditional sources. An extensive selection of configurations and options make the BLT the perfect choice for many lighting applications including schools, offices and other commercial spaces, retail, hospitals and healthcare facilities.

The low profile BLT design (2-3/8") also makes it an excellent choice for renovation projects.

CONSTRUCTION — Prior to fabrication, BLT components are coated with a proprietary paint blend and die-formed for dimensional consistency.

The BLT reflector is available in both smooth and ribbed finishes. Choose RB from the fixture style section below for a ribbed finish.

End plates contain easy-to-position integral T-bar clips for securely attaching the luminaire to the T-grid. For additional T-grid security, optional screw on T-bar clips are available.

Diffusers are extruded from impact modified acrylic for increased durability.

LED boards and drivers are accessible from the plenum.

OPTICS — Volumetric illumination is achieved by creating an optimal mix of light to walls, partitions and vertical and horizontal work surfaces – rendering the interior space, objects and occupants in a more balanced, complimentary luminous environment. A typically configured 2BLT2 features a Unified Glare Rating (UGR) starting at 18, UGR data available on page 8. High performance extruded acrylic diffusers conceal LEDs and efficiently deliver light in a volumetric distribution.

Five diffuser choices available - curved and square designs with ribbed or a smooth frosted finish.

ELECTRICAL — Long-life LEDs, coupled with high-efficiency drivers, provide superior quantity and quality of illumination for extended service life. 80% LED lumen maintenance at 60,000 hours (L80/60,000). Color Variation within 3-step MacAdam ellipse (3SDCM).

Non-Configurable BLT: Generic 0-10 volt dimming driver. Dims to 10% Configurable BLT: available in High Efficiency (HE) versions for applications where a lower wattage (over the standard product) is required. The High Efficiency versions deliver >130 LPW and can be specified via the Lumen Package designations in the Ordering Information below.

eldoLED driver options deliver choice of dimming range, and choices for control, while assuring flicker-free, low-current inrush, 89% efficiency and low EMI.

Optional integrated nLight®controls make each luminaire addressable - allowing them to digitally communicate with other nLight enabled controls such as dimmers, switches, occupancy sensors and photocontrols. Connection to nLight is simple.

It can be accomplished with integrated nLight AIR wireless rIO and rES7 sensors, or through standard Cat-5 cabling. nLight offers unique plug-and-play convenience as devices and luminaires automatically discover each other and self-commission.

nLight AIR is commissioned easily through an intuitive model app.

Lumen Management: Unique lumen management system (option N80) provides on board intelligence that actively manages the LED light source so that constant lumen output is maintained over the system life, preventing the energy waste created by the traditional practice of over-lighting.

Step-level dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance.

SENSOR— Integrated sensor (individual control): Sensor Switch MSD7ADCX ((Passive infrared (PIR)) or MSDPDT7ADCX ((PIR/Microphonics Dual Tech (PDT)) integrated occupancy sensor/automatic dimming photocell allows the luminaire to power off when the space is unoccupied or enough ambient light is entering the space. See page 4 for more details on the integrated sensor.

Integrated Sensor (nLight Wired Networking): This sensor is nLight-enabled, meaning it has the ability to communicate over an nLight network. When wired, using CAT-5 cabling, with other nLight-enabled sensors, power packs, or WallPods, an nLight control zone is created. Once linked to a Gateway, directly or via a Bridge, the zone becomes capable of remote status monitoring and control via SensorView software. See page 4 for the nLight sensor options.

Integrated Smart Sensor (nLight Air Wireless Platform): The RES7 sensor is nLight AIR enabled, meaning it has the ability to communicate over the wireless nLight control platform. It is available with an automatic dimming photocell, and either a digital PIR or a microphonics (PDT) dual technology occupancy sensor. It pairs to other luminaires and wall switches through our mobile app, CLAIRITY+, which allows for simple sensor adjustment. See page 4 for more details on the Integrated Smart Sensor.

Integrated Wireless Sensor (single room control): Sensor Switch VERTEX JOT or JOTVTX15 luminaire-embedded occupancy and ambient light sensor allows the luminaire to power off when the space is unoccupied or when enough ambient light is entering the space. See page X for more details on the integrated wireless sensor.

INSTALLATION — The BLT's low profile design of only 2-3/8" provides increased installation flexibility especially in restrictive plenum applications. Designed for use in NEMA standard Type G (1" & 15/16") , NFG (9/16"), and SS (9/16") grid ceilings. Consult factory about other ceiling types.

For recessed mounting in hard ceiling applications, Drywall Grid Adapters (DGA) are available as an accessory.

See Accessories section. Suitable for damp location.

LISTINGS — CSA Certified to meet U.S. and Canadian standards. IC rated. Tested in accordance with ISO 14644-1; suitable for ISO Class 5-9 positive and negative pressure clean rooms.

DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.

org/QPL to confirm which versions are qualified.

BUY AMERICAN ACT— Product with the BAA option is assembled in the USA and meets the Buy America(n) govern-ment procurement requirements under FAR, DFARS and DOT regulations. Please refer to www.acuitybrands.com/ buy-american for additional information.

WARRANTY — 5-year limited warranty. This is the only warranty provided and no other statements in this speci-fication sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions NOTE: Actual performance may differ as a result of end-user environment and application.

All values are design or typical values, measured under laboratory conditions at 25 °C.

Specifications subject to change without notice.

Embed nLight controls today. Prepare for tomorrow.

User-friendly install Scalability

Enhanced energy savings Space configuration

Code compliance Future-ready

Now Tomorrow

Specifications

Length: 23-3/4 (60.3)

Width: 23-3/4 (60.3)

Depth: 2-3/8 (6.0)

Depth with Air supply/return: 2-3/4 (6.9)

All dimensions are inches (centimeters) unless otherwise specified.

Static

Air Supply/Return

Ribbed Reflector Option

ADP Diffuser Option

ISO

Class 5-9

Items marked by a shaded background qualify for the Design Select program and ship in 15 days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect.

*See ordering tree for details

Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning when used with Acuity Brands controls products.

All configurations of this luminaire are calibrated and tested to meet the Acuity Brands' specifications for chromatic consistency – including color rendering, color fidelity, and color temperature tolerance around standard CIE chromaticity coordinates.

To learn more about Acuity A+ standards, specifications, and testing visit www.acuitybrands.com/aplus.

Ordering Tree

DIGITAL NAVIGATION

nLight Platform Sensor Switch JOT Photometrics Performance Data http://www.designlights.org/QPL http://www.designlights.org/QPL http://www.acuitybrands.com/buy-american http://www.acuitybrands.com/buy-american http://www.acuitybrands.com/support/warranty/terms-and-conditions https://www.acuitybrands.com/-/media/abl/acuitybrands/files/resources/customer-tools/lighting-design-resources/ab-ugr-faq.pdf?forceBehavior=open https://www.acuitybrands.com/resources/buy-american http://www.acuitybrands.com/designselect http://www.acuitybrands.com/aplus

2BLT Volumetric Recessed Lighting 2'x2'

BLT-2X2

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23

ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: 2BLT2 33L ADP EZ1 LP835

2BLT2

Series Fixture Style Air function Lumens ‡ Diffuser Voltage Driver Color temperature

2BLT2 2X2 BLT (blank) Smooth Reflector

RB Ribbed Reflector

(blank) Static A Air supply/ return ‡

Standard efficiency ‡

(>125 LPW)

20L 2000 33L 3300 40L 4000 48L 4800

High efficiency ‡

(>130 LPW)

20LHE 2000

33LHE 3300

40LHE 4000

48LHE 4800

ADP Curved, ribbed ADSM Curved, smooth SDP Square, ribbed SDSM Square, smooth LUGR Low UGR lens‡ Includes trim rings to match sensored version ADPT Curved, ribbed ADSMT Curved, smooth SDPT Square, ribbed SDSMT Square, smooth LUGRT Low UGR lens with trim‡

(blank) MVOLT 120 120V 277 277V 347 347V ‡

EZ1 eldoLED dims to 1% (0-10 volt dimming)

GZ1 Dims to 1% (0-10V dimming)

GZ10 Dims to 10% (0-10V dimming)

SLD Step-level dimming ‡

LP830 82CRI, 3000 K

LP835 82CRI, 3500 K

LP840 82CRI, 4000 K

LP850 82CRI, 5000 K

LP930 90CRI, 3000K

LP935 90CRI, 3500K

LP940 90CRI, 4000K

LP950 90CRI, 5000K

nLight Interface Control ‡ nLight Wired (blank) no nLight ® interface N80 nLight with 80% lumen management N80EMG nLight with 80% lumen management

For use with generator supply EM power ‡ N100 nLight without lumen management N100EMG nLight without lumen management

For use with generator supply EM power ‡ nLight Wireless (blank) no nLight ® interface NLTAIR2 nLight AIR Generation 2 enabled ‡ nLight Wired (blank) No sensor control NES7 nLight™ nES 7 PIR integral occupancy sensor ‡ NESPDT7 nLight™ nES PDT 7 dual technology integral occupancy control ‡ NES7ADCX nLight™ nES 7 ADCX PIR integral occupancy sensor with automatic dimming photocell ‡ NESPDT7ADCX nLight™ nES PDT 7 dual technology integral occupancy sensor with automatic dimming photocell ‡ nLight Wireless

RES7 nLight AIR control with PIR integral occupancy sensor and automatic dimming photocell ‡

RES7PDT nLight AIR control with PDT dual technology integral occupancy sensor and automatic dimming photocell ‡

RIO nLight AIR radio module without sensor ‡ RES7EM nLight AIR PIR integral occupancy sensor with automatic dimming photocell and UL924

Emergency Operation, via power interrupt detection ‡ RES7PDTEM nLight AIR microphonics dual technology occupancy sensor with automatic dimming photocell and UL924 Emergency Operation, via power interrupt detection ‡ RIOEM nLight AIR radio module less sensor, with UL924 Emergency Operation, via power interrupt detection ‡

Individual Control MSD7ADCX PIR integral occupancy sensor with automatic dimming control photocell ‡

MSDPDT7ADCX PDT integral occupancy sensor with automatic dimming control photocell ‡

JOT Wireless room control with “Just One Touch" pairing ‡

JOTVTX15 Wireless occupancy sensor with “Just One Touch" pairing ‡

Standy Mode Options

NOC NOC Occupancy sensor disabled ‡

BDP Disconnect Plug EL7L 700 lumen battery pack

(Noncompliant with CA T20) ‡ EL14L 1400 lumen battery pack

(Noncompliant with CA T20) ‡ E10WLCP EM Self-Diagnostic battery pack, 10W Constant Power, Certified in CA Title 20 MAEDBS ‡

CP Chicago plenum ‡ BGTD Bodine Generator Transfer Device ‡ PWS1836 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit PWS1846 6' pre-wire, 3/8" diameter, 18 gauge, 2 circuit PWS1846 PWSLV Two cables: one 6' pre-wire, 3/8" diameter, 18 gauge, 2 circuits; one 6' pre-wire, 3/8" diameter, 18 gauge ‡

PWS1856LV 6' pre-wire, 3/8" diameter, 18 gauge, 1 circuit w/ low voltage wires ‡

GLR Fast-blowing fuse ‡ GMF Slow-blowing fuse ‡ NPLT Narrow pallet RRL_ RELOC®-ready luminaire ‡ LATC Earthquake clip WH Glossy White DWAM Anti-Microbial paint JP28 Job packaging ‡ JP44 Job packaging ‡ IP5X Gasketed diffuser compartment to meet IP5X rating ‡ BAA Buy America(n) Act Compliant

NOTE: ‡ indicates option value has ordering restrictions. Please reference the Option Value Ordering Restictions chart on the next page. Options are sorted alphanumerically.

Design Select options indicated by this color background.

http://www.lithonia.com

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23

‡ Option Value Ordering Restrictions

Option value Restriction 347 Not available with SLD, EL7L, EL14L, or E10WLCP options.

A Not available with RB fixture style, consult factory for air flow data. If a job pack is selected, use JP28 only.

BGTD Not available with JOT, JOTVTX15 sensor options or emergency battery options. Must specify voltage. Requires BSE labeling, voltage specific. Consult factory for options. Example:

BGTD BSE10.

Control Must specify diffuser with trim rings.

CP Not available with N80, N80EMG, N100, N100EMG, PWS1836, PWS1846, PWS1846 PWSLV or PWS1856LV.

EL7L, EL14L, E10WLCP When using pre-wire option, use PWS1846 or PWS1846 PWSLV.

GLR, GMF Must specify voltage. 120 or 277, with GLR and GMF fusing.

IP5X Not available with air supply/return or Wired Networking (NES_) and Individual Control (MSD_) sensors.

JOT, JOTVTX15 Not available with SLD, nLight, NLTAIR2, NOC, or BGTD options.

JP28 Only available with options: NES7, NESPDT7, NES7ADCX, NESPDT7ADCX, MSD7ADCX, MSDPDT7ADCX, RES7, RES7PDT, RIO, JOT, JOTVTX15. Not available when sensor options combined with 'A' air supply return option.

JP44 Not available with NES7, NESPDT7, NES7ADCX, NESPDT7ADCX, MSD7ADCX, MSDPDT7ADCX, RES7, RES7PDT, RIO, JOT, JOTVTX15. Not available 'A' air supply return option.

Lumens Approximate lumen output. For high Efficiency, all versions may not achieve 130+ LPW. Refer to photometry on www.acuitybrands.com. Air supply/return option, 90 CRI, and versions with integral sensor trim rings may not achieve 130 LPW.

LUGR, LUGRT Due to the unique optics used to drive the low UGR distribution, the LUGR lens is not uniformly lit and presents visible striping.

MSD7ADCX, MSDPDT7ADCX Only available with EZ1 driver option. 0-10v dimming wires not accessible via access plate.

NES7, NESPDT7, NES7ADCX, NESPDT7ADCX Requires N80, N80EMG, N100, or N100EMG. Only available with EZ1 driver.

NLTAIR2 Must order with nLight Wireless option from Control section. Not available with GZ10 driver.

NOC Can only be ordered in conjunction with EZ1 or GZ1, NLTAIR2, RES7/RES7PDT. Occupancy sensor disabled at factory but can be re-enabled upon commissioning.

N80EMG, N100EMG nLight EMG option requires a connection to existing nLight network. Power is provided from a separate N80 or N100 enabled fixture.

PWS1846 PWSLV, PWS1856LV Not available with nLIGHT wired network or individual controls RES7, RES7PDT, RIO See UL 924 Sequence of Operation chart on page 3. When combined with the EZ1 option, can be used as a normal power sensing device for nLight AIR devices and luminaires with

EM emergency options.

RES7EM, RES7PDTEM, RIOEM See UL924 Sequence of Operation chart on page 3. Not available with GZ10 or GZ1 driver.

RRL_ For ordering logic consult: RRL_2013.

SLD Not available with any nLight Interface or Control options.

Stock/MTO Catalog Description * UPC Lumens Wattage LPW Color Temperature Voltage Pallet Qty Stock 2BLT2 33L ADP LP835 190887529708 3332 26.67 124.92 3500K/82 CRI 120-277 56

2BLT2 33L ADP LP840 190887529739 3385 26.67 126.91 4000K/82CRI 120-277 56

2BLT2 33L ADP EL14L LP835 190887529890 3332 26.67 124.92 3500K/82CRI 120-277 56

2BLT2 33L ADP EL14L LP840 190887529937 3385 26.67 126.91 4000K/82CRI 120-277 56

*Generic 0-10V Dimming to 10%.

Non-Configurable BLT

MOUNTING DATA

Ceiling Type Appropriate Trim Type

Exposed grid tee (1' and 9/16") G

Concealed grid tee G

Plaster or plasterboard G*

*DGA accessory available to provide ceiling trim flange and fixture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA installation is 24-3/4" x 24-3/4" (Tolerance is +1/8", -0").

9/16 Screw Slot15/16

SDSM Diffuser Option

UL924 Sequence of Operation

The below information applies to all nLight AIR devices with an EM option.

• EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds.

• Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts.

• Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing.

Multiple Diffuser Options

Curved Ribbed

ADP

Square Ribbed

SDP

Square Smooth

SDSM ADSM

Curved Smooth

LUGR

Low UGR https://img.acuitybrands.com/public-assets/catalog/248102/rrl.pdf?abl_version=05%2f18%2f2021+20:31:30&DOC_Type=SPEC_SHEET

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23

Accessories: Order as separate catalog number.

DGA22 Drywall grid adapter for 2x2 recessed fixture 2X2SMKSHP PAF Surface Mount Troffer Kit Post Paint RK8BDP 2P U Disconnect Plug (BDP), 2 Pole, Package of 1 RK8BDP 3P U Disconnect Plug (BDP), 3 Pole, Package of 1 RK8BDP 2P J10 Disconnect Plug (BDP), 2 Pole, Package of 10 RK8BDP 2P J40 Disconnect Plug (BDP), 2 Pole, Package of 40

Replacement Parts: Order as separate catalog number.

*247WJV 2DBLT24 ADP LENS ASSEMBLY 2 ft. replacement lens *249P2P 2DBLT24 SDP LENS ASSEMBLY 2 ft. replacement lens *249P2W 2DBLT24 ADSM LENS ASSEMBLY 2 ft. replacement lens *249P32 2DBLT24 SDSM LENS ASSEMBLY 2 ft. replacement lens *237LT1 2DBLT24 ADPT LENS ASSEMBLY 2 ft. replacement lens *237LT3 2DBLT24 SDPT LENS ASSEMBLY 2 ft. replacement lens *237LT5 2DBLT24 ADSMT LENS ASSEMBLY 2 ft. replacement lens *237LT7 2DBLT24 SDSMT LENS ASSEMBLY 2 ft. replacement lens *237LT9 2DBLT24 ADPT SENSOR LENS ASSEMBLY 2 ft. replacement lens *237M4Y 2DBLT24 SDPT SENSOR LENS ASSEMBLY 2 ft. replacement lens *237M57 2DBLT24 ADSMT SENSOR LENS ASSEMBLY 2 ft. replacement lens *237M5H 2DBLT24 SDSMT SENSOR LENS ASSEMBLY 2 ft. replacement lens

Accessories & Replacement Parts

Sensor Switch JOT Enabled Wireless Solution

1. Power: Install JOT enabled fixtures and controls as instructed.

2. Pair: Insert the pairing tool into the pinhole on the wall switch; press and hold any button for 6 seconds.

3. Play: Once paired, each fixture will individually dim down to 10% brightness. All products will be fully functional.

BLT Series

Sensor Switch

WSXA JOT

Designed with contractors in mind, the Sensor Switch JOT enabled wireless solution offers a straightforward approach to the installation and pairing of lighting fixtures and controls. Absolutely no 0-10V control wires and no mobile apps are needed with JOT enabled products, allowing for lightning speed installation right out of the box.

BLT Series with integrated

JOT OCC

Sensors

Sensor Switch

SPODMRA JOT

JOT Wireless

Emergency Battery Pack Options - Field Installable Battery Model Number Wattage Runtime

(Minutes) Lumen Output*

@ 120 Lumens/Watt Other

ILB CP07 2H A 7W 120 840 Storm Shelter/ 2-hour Runtime

ILB CP10 A 10W 90 1200

ILBLP CP10 HE SD A 10W 90 1200 Title 20, Self Diagnostic ILBLP CP15 HE SD A 15W 90 1800 Title 20, Self Diagnostic ILB CP20 HE A 20W 90 2400 Title 20 ILB CP20 HE SD A 20W 90 2400 Title 20, Self Diagnostic All the above are UL Listed products that are certified for field install external/remote to the fixture.

*Minimum delivered lumen output to assist in product selection for increased fixture mounting height.

The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast.

Please contact us at techsupport@iotaengineering.com for any Emergency Battery related questions.

http://www.lithonia.com https://www.iotaengineering.com/products/detail/1009403/ https://www.iotaengineering.com/products/detail/1009409/ https://www.iotaengineering.com/products/detail/1233619/ https://www.iotaengineering.com/products/detail/1233623/ https://www.iotaengineering.com/products/detail/1009434/ https://www.iotaengineering.com/products/detail/1009437/ mailto:techsupport%40iotaengineering.com?subject=

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23

NH NH NH

BLT Series nLight Wired nPODMA

CAT5e

NH NH NH

BLT Series nLight AIR rPODBA Mobile Device nLight Platform nLight embedded fixtures offer: Customers get:

Manual Dimming Convenience and visual comfort for occupants

Motion Sensing and/or Daylight Harvesting Energy savings and code compliance

Fixture or Group Level Control Ability to configure lighting to the space requirements

Flexibility Ease of fixture moves, adds and changes

Wireless Wall Switch (nLight AIR Only) Ease and flexibility of placement

Astronomical and Time of Day Scheduling Energy savings and building security

Scalable Solution nLight controls to grow with your business

Future-Ready nLight platform to set foundation for future upgrades and capabilities

Simple as 1,2,3

1. Install the nLight® AIR fixtures with embedded smart sensor

2. Install the wireless battery-powered wall switch

3. With CLAIRITY+ app, pair the fixtures with the wall switch and if desired, customize the sensor settings for the desired outcome

Simple as 1,2,3

1. Install the nLight® Wired fixtures with embedded control

2. Install the nLight Wired wall switch

3. Connect the fixtures using standard CAT5e cables and the devices will automatically discover each other and work (plug and play) nLight Air Wireless nLight Wired Networking

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23

Sensor Options

Option Automatic Dimming Photocell

Occupancy Sensing nLight Wired Networking nLight AIR NetworkingPIR PDT

MSD7ADCX X X

MSDPDT7ADCX X X

NES7 X X

NES7ADCX X X X

NESPDT7 X X

NESPDT7ADCX X X X

RES7 X X X

RESPDT7 X X X X

Integrated Sensor with Individual Control The MSD7ADCX PIR occupancy sensor/automatic dimming photocell is ideal for areas without obstructions and where daylight harvesting may be desired. Suggested applications include, but not limited to, hallways, corridors, storage rooms, and breakrooms or other areas where people are typically moving.

The MSDPDT7ADCX PIR/Microphonics Dual Tech occupancy sensor/automatic dimming photocell is ideal for areas with obstructions and where daylight harvesting is desired. Suggested applications include, but not limited to, open offices, private offices, classrooms, public restrooms, and conference rooms.

Sequence of Operation (nES7 and rES7 and Sensor)

MIN

LIG

HT

LE

VE

L

MAX

7.5 MIN

TIME DELAY

2.5 MIN AT

A 1% LEVEL

LIGHTS OFF LIGHTS ONLIGHTS ON

Room Unoccupied

Occupants Detected In The Space

Sensor Detects Motion

MOTION NO MOTION MOTION

SEQUENCE OF OPERATION

5.5 18

4.6 15

3.7 12

2.7 9

1.8 6

0.9 3 0 m 0 ft

0.9 3

1.8 6

2.7 9

3.7 12

4.6 15

5.5 18

9 FT Mounting

• Recommended for walking motion detection from mounting heights between 8 ft (2.44 m) and 20 ft (6.10 m)

• Initial detection of walking motion along sensor axes at distances of 2x the mounting height up to 15 ft (4.57 m) and

• 1.75x up to 20 ft (6.10 m).

• Provides 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m)

• Initial detection will occur earlier when walking across sensor's field of view than when walking directly at sensor

Sensor Coverage Pattern Mini 360° Lens

*The presetting on the automatic dimming photocell is 5fc (NES7) and 10fc (RES7).

Sequence of Operation (MSD7 Sensor)

MIN

LIG

HT

LE

VE

L

MAX

17.5 MIN

TIME DELAY

2.5 MIN AT

A 1% LEVEL

LIGHTS OFF LIGHTS ONLIGHTS ON

Room Unoccupied

Occupants Detected In The Space

Sensor Detects Motion

MOTION NO MOTION MOTION

SEQUENCE OF OPERATION

*The presetting on the automatic dimming photocell is 5fc.

nLight AIR Wireless nLight AIR is the ideal solution for retrofit or new construction spaces where adding additional wiring can be labor intensive and nLight AIR is available with or without an integral sensor. The integrated rES7 or rES7PDT smart sensors are part of each luminaire in the nLight AIR network, which can be grouped to control multiple luminaires. The granularity of control with the digital PIR occupancy detection and daylight sensing makes a great solution for any application.

nLight Wired Networking The nES 7 is ideal for small rooms without obstructions or areas with primarily walking motion.

Ideal areas include hallways, corridors, storage rooms, and breakrooms. Additionally, the nES7ADCX includes an integrated photocell, which enables daylight harvesting controls.

For areas like restrooms, private offices, open offices, conference rooms or any space with obstructions, the nES PDT 7 dual technology sensor is recommended. The nES PDT 7 utilizes both PIR (passive infrared) and Microphonics technologies to detect occupancy. Additionally, the nESPDT7ADCX includes an integrated photocell, which enables daylight harvesting controls which is ideal for areas where windows are present.

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23 nLight® Wired Control Accessories:

Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight.

WallPod stations Model number Occupancy sensors Model number On/Off nPODMA [Color] Small motion 360°, ceiling (PIR / dual tech) nCM 9 RJB / nCM PDT 9 RJB On/Off & raise/lower nPODMA DX [Color] Large motion 360°, ceiling (PIR / dual tech) nCM10 RJB / nCM PDT 10 RJB Graphic touchscreen nPOD TOUCH [Color] Wall switch with raise/lower nWSX PDT LV DX [color] Photocell controls Model number Cat-5 cable (plenum rated) Model number Full range dimming nCM ADCX RJB 10' cable CAT5 10FT J1

30' cable CAT5 30FT J1 nLight® AIR Control Accessories:

Order as separate catalog number. Visit www.acuitybrands.com/products/ controls/nlightair.

Wall switches Model number On/Off single pole rPODBA [color] G2 On/Off two pole rPODB A2P [color] G2 On/Off & raise/lower single pole rPODBA DX [color] G2 On/Off & raise/lower two pole rPODBA 2P DX [color] G2

RCMS

Notes 1 RCMS requires low voltage power from either RPP20 DS 24V G2 or PS150.

rCMS1 Example: RCMS PDT 10 AR G2

Series / Detection Power Supply1 Occupancy Detection Lens (Required) Operating Mode Generation

RCMS nLight AIR occupancy and daylight sensor

[blank] Power Supply ordered separately

PS 150 Standard 150 mA Power Supply

[blank] PIR Detection PDT Dual Tech PIR/

Microphonics

10 Large Motion/ Extended Range 360°

9 Small Motion/ Extended Range 360°

6 High Bay 360° Lens

[BLANK] None AR Auxiliary

Relay

G2 Generation 2 compatibility

Controls Accessories

Sensor Switch

WSX

nLight WIRED nPODMA DX nLight AIR rPODBA rPODBA

Winning in Small OffiesWinning in Small Offies

BLT fixtures with integrated rIO devices complement any small office space. Pair them with an rCMS occupancy sensor and the space now has wireless occupancy sensing and dimming capability. For additional configuration options please consult with Tech Support.

BLT with rIOnLight WIRED

NPOD UNITOUCH

http://www.lithonia.com http://www.acuitybrands.com/products/controls/nlight http://www.acuitybrands.com/products/controls/nlightair http://www.acuitybrands.com/products/controls/nlightair https://www.acuitybrands.com/products/detail/708905/sensor-switch/wsx-series/wall-switch-sensor https://www.acuitybrands.com/products/detail/708905/sensor-switch/wsx-series/wall-switch-sensor https://www.acuitybrands.com/products/detail/982001/nlight/npodma-family/nlightr-wired-wall-switch https://www.acuitybrands.com/products/detail/982001/nlight/npodma-family/nlightr-wired-wall-switch https://www.acuitybrands.com/products/detail/982003/nlight/rpodba-family/nlightr-air-wall-switch https://www.acuitybrands.com/products/detail/982003/nlight/rpodba-family/nlightr-air-wall-switch https://www.acuitybrands.com/products/detail/981468/nlight/nlightr-unitouch/touchscreen-wall-switch https://www.acuitybrands.com/products/detail/981468/nlight/nlightr-unitouch/touchscreen-wall-switch

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23

PHOTOMETRICS

2BLT2 33L ADP LP835, 3332 delivered lumens, test no. ISF36900P19, tested in accordance to IESNA LM-79

2BLT2 40L ADP LP835, 4041 delivered lumens, test no. ISF36900P35, tested in accordance to IESNA LM-79

0° 20°

40°

60°

80°

90°

0°0°0° 90°

180°

Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10%

R C

R

Zonal Lumen Summary

Zone Lumens % Lamp % Fixture

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

25.6

41.7

74.0

100.0

0.0

0.0

0.0

0.0

100.0

25.6

41.7

74.0

100.0

0.0

0.0

0.0

0.0

100.0

CP Summary

0° 90

0°

5°

15°

25°

35°

45°

55°

65°

75°

85°

0° 20°

40°

60°

80°

90°

0°0°0° 90°

180°

Coefficients of Utilization pf 20% pc 80% 70% 50% pw 70%50%30% 50%30%10% 50%30%10%

R C

R

Zonal Lumen Summary

Zone Lumens % Lamp % Fixture

0° - 30°

0° - 40°

0° - 60°

0° - 90°

90° - 120°

90° - 130°

90° - 150°

90° - 180°

0° - 180°

25.6

41.7

74.0

100.0

0.0

0.0

0.0

0.0

100.0

25.6

41.7

74.0

100.0

0.0

0.0

0.0

0.0

100.0

CP Summary

0° 90

0°

5°

15°

25°

35°

45°

55°

65°

75°

85°

Enabled by the embedded nLight control, the BLT actively tracks its run-time and manages its light source such that constant lumen output is maintained over the system life. Referred to as lumen management, this feature eliminates the energy waste created by the traditional practice of over-lighting.

0 10 20 30 40 50

THOUSAND OPERATING HOURS

0 10 20 30 40 50

THOUSAND OPERATING HOURS

POWER INPUT

LIGHT

OUTPUT

100%

80%

100%

80%

30W

24W

30W

24W

LI

G

H T

O U

TP

U

T

LI

G

H T

O U

TP

U

T

PO

W

ER

IN

PU

ER

IN

PU

T

Without Lumen Management Energy is wasted and light level is inconsistent.

POWER

INPUT

LIGHT OUTPUT

With Lumen Management Energy is saved and light level remains consistent.

Wasted Energy

Saved Energy

0 10 20 30 40 50

THOUSAND OPERATING HOURS

0 10 20 30 40 50

THOUSAND OPERATING HOURS

POWER INPUT

LIGHT

OUTPUT

100%

80%

100%

80%

30W

24W

30W

24W

LI

G

H T

O U

TP

U

T

LI

G

H T

O U

TP

U

ER

IN

PU

ER

IN

PU

T

Without Lumen Management Energy is wasted and light level is inconsistent.

POWER

INPUT

LIGHT OUTPUT

With Lumen Management Energy is saved and light level remains consistent.

Wasted Energy

Saved Energy

Constant Lumen Management

Lumen Package

UGR Values of BLT 2x2 @ 80CRI and 3500K UGR (70% 50% 20% reflectance using a 4H x 8H room size)

ADP ADPT ADSM ADSMT SDP SDPT SDSM SDSMT LUGR LUGRT

Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise Crosswise Endwise

20L 17.8 21.6 17.8 21.8 17.7 21.4 18 21.1 18.3 21.3 18 21 18.1 21.5 18 20.9 16.3 17.9 17.6 18.2 20LHE 17.6 21.5 17.6 21.6 19.5 22.8 17.6 21.5 17.8 21.4 17.6 21.5 17.9 21.3 17.9 21.4 16.1 17.7 17.4 18

33L 19.5 23.3 19.5 22.8 19.9 23.2 19.3 22.4 19.6 22.6 19.3 22.3 19.6 22.3 19.4 22.2 18 19.6 19.3 19.8 33LHE 19.7 23.3 19.7 23.1 20.5 23.7 19.7 22.8 20 23 19.7 22.7 19.8 23.2 19.8 22.6 17.9 19.5 19.2 19.8

40L 20.2 24 20.3 23.7 20.5 23.8 20.2 24 20.5 23.5 20.2 23.2 20.5 23.2 20.3 23.2 18.7 20.3 20 20.5 40LHE 20.2 24.1 20.3 23.7 20.9 24.6 20.2 23.4 20.5 23.5 20.2 23.3 20.5 23.2 20.3 23.2 18.7 20.3 20 20.5

48L 20.8 24.6 20.7 24.8 20.9 24.6 20.8 24.6 21 24.5 20.7 24.6 21 24.5 21 24.5 19.4 21.1 20.7 21.3 48LHE 20.7 24.3 20.7 24.1 20.9 24.2 20.8 24.6 21 24 20.7 23.7 20.9 23.7 20.8 23.6 19.4 21 20.7 21.2

UGR varies based on luminaire options and is affected by application dependent parameters. Numbers depicted here are considered “Luminaire-UGR and/or “Point-UGR” values.

To determine a more precise maximum UGR value (“Application-UGR”), a full lighting design layout should be completed with the selected luminaire configuration for each application

UNIFIED GLARE RATING (UGR)

COMMERCIAL INDOOR: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/24/23

Performance Data Model Number Lumens LPW Watts DLC Listing DLC ID 2BLT2 20L ADP EZ1 (GZ1, GZ10) LP840 2092 127.8 16.4 Premium PM92196A

2BLT2 20L ADP EZ1 (GZ1, GZ10) LP835 2036 124.4 16.4 Premium P6445UVD

2BLT2 20L ADPT EZ1 (GZ1, GZ10) LP840 2061 125.9 16.37

2BLT2 20L ADPT EZ1 (GZ1, GZ10) LP835 2008 122.7 16.37

2BLT2 33L ADP EZ1 (GZ1, GZ10) LP835 3300 124.6 26.5 Premium PHSXHE8F

2BLT2 33L ADP EZ1 (GZ1, GZ10) LP840 3391 128.1 26.5 Premium PD18CKQ8

2BLT2 33L ADPT EZ1 (GZ1, GZ10) LP840 3343 126.3 26.5 Premium PF98CZ2H

2BLT2 33L ADPT EZ1 (GZ1, GZ10) LP835 3254 122.9 26.5 Premium S-OIDCZL

2BLT2 40L ADP EZ1 (GZ1, GZ10) LP835 4034 130.2 31 Premium P1XWW9GV

2BLT2 40L ADP EZ1 (GZ1, GZ10) LP840 4144 133.8 31 Premium PHCQ2CQF

2BLT2 40L ADPT EZ1 (GZ1, GZ10) LP835 3977 128.4 31 Premium PW6RMMJ4

2BLT2 40L ADPT EZ1 (GZ1, GZ10) LP840 4086 131.9 31 Premium P5YYDAA8

2BLT2 48L ADP EZ1 (GZ1, GZ10) LP835 5022 117.2 42.9 Standard PJRH1R1G

2BLT2 48L ADP EZ1 (GZ1, GZ10) LP840 5159 120.4 42.9 Standard P8G93YOK

2BLT2 48L ADPT EZ1 (GZ1, GZ10) LP835 4951 115.5 42.9 Standard PITU3V6X

2BLT2 48L ADPT EZ1 (GZ1, GZ10) LP840 5087 118.7 42.9 Standard P5X2XU76

HE Performance Data Model Number Lumens LPW Watts DLC Listing DLC ID 2BLT2 20LHE ADP EZ1 (GZ1, GZ10) LP835 1939 132.3 14.7 Premium PUQCZNQI

2BLT2 20LHE ADP EZ1 (GZ1, GZ10) LP840 1992 135.9 14.7 Premium PJCZRW21

2BLT2 20LHE ADPT EZ1 (GZ1, GZ10) LP840 1964 134.0 14.7 Premium PLC4RF4L

2BLT2 33LHE ADP EZ1 (GZ1, GZ10) LP835 3247 133.0 24.4 Premium PXXZN9PH

2BLT2 33LHE ADP EZ1 (GZ1, GZ10) LP840 3336 136.7 24.4 Premium PKPJYYRF

2BLT2 33LHE ADPT EZ1 (GZ1, GZ10) LP835 3202 131.1 24.4 Premium PZC8BZSS

2BLT2 33LHE ADPT EZ1 (GZ1, GZ10) LP840 3290 134.7 24.4 Premium PM5G8AFU

2BLT2 40LHE ADP EZ1 (GZ1, GZ10) LP835 4044 135.5 29.9 Premium PJ55XFFP

2BLT2 40LHE ADP EZ1 (GZ1, GZ10) LP840 4155 139.2 29.9 Premium PEGFHPZD

2BLT2 40LHE ADPT EZ1 (GZ1, GZ10) LP835 3987 133.6 29.9 Premium P8E16E9B

2BLT2 40LHE ADPT EZ1 (GZ1, GZ10) LP840 4096 137.2 29.9 Premium PFRSSSVG

2BLT2 48LHE ADP EZ1 (GZ1, GZ10) LP835 4944 139.8 35.4 Premium P558XUZP

2BLT2 48LHE ADP EZ1 (GZ1, GZ10) LP840 5080 143.6 35.4 Premium P1863H56

2BLT2 48LHE ADPT EZ1 (GZ1, GZ10) LP835 4875 137.8 35.4 Premium PHPTG5M8

2BLT2 48LHE ADPT EZ1 (GZ1, GZ10) LP840 5009 141.6 35.4 Premium PBKN954Z

DLC information is subject to change, for the most up-to-date information please refer to www.dlc.org. Above listings do not cover 347v or SLD.

DLC information is subject to change, for the most up-to-date information please refer to www.dlc.org. Above listings do not cover 347v or SLD.

How to Estimate Delivered Lumens in Emergency Mode Use the formula below to estimate the delivered lumens in emergency mode Delivered Lumens = 1.25 x P x LPW P = Ouput power of emergency driver. P = 10W for E10WLCP option.

LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet. LPW = Lumen per watt rating of the luminaire. LPW information available in Performance Data section.

http://www.lithonia.com

Catalog Number:
Notes:
Type:
Air Function:
Lumens:
Diffuser:
Voltage:
Driver:
Color Temp:
Lumens 2:
Controls 3:
Occupancy Controls 3:
Options 3:
Occupancy Controls 4:
Accessories:
Replacement Parts:
nLight Wired Control Accessories 2:
nLight AIR Control Accessories 2:
nLight AIR Control Accessories 3:
nLight AIR Control Accessories 4:
nLight AIR Control Accessories 5:
nLight AIR Control Accessories 6:
nLight AIR Control Accessories 7:
nLight AIR Control Accessories 8:

File details come from the government source that posted it. Updated .