This file contains details of a federal solicitation for maintenance dredging services. The U.S. Army Corps of Engineers, New York District, is seeking bids to dredge the Shrewsbury River Federal Navigation Channel in New Jersey under solicitation number W912DS23B0017. Interested vendors must dredge the channel to authorized depths and dispose of dredged materials at an approved upland site. The solicitation does not specify response or award dates but rather provides information on the location and scope of dredging services required by the agency.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ANALYTICAL REPORT
PREPARED FOR
Attn: Carole Peven McCarthy
Battelle 141 Longwater Dr
Suite 202 Norwell MA 02061
Generated 4/27/2023 4:52 PM
JOB DESCRIPTION
Shrewsberry NJ
JOB NUMBER
180-153025-2
See page two for job notes and contact information.
Pittsburgh PA 15238 RIDC Park 301 Alpha Drive Eurofins Pittsburgh https://eol.et.eurofinsus.com/myEOL/ http://
Eurofins Pittsburgh
Eurofins Pittsburgh is a laboratory within Eurofins Environment Testing Northeast LLC, a company within Eurofins Environment Testing Group of Companies
Job Notes The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available.
Any exceptions to the NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory. This report is confidential and is intended for the sole use of Eurofins Environment Testing Northeast, LLC Pittsburgh and its client. All questions regarding this report should be directed to the Eurofins Environment Testing Northeast, LLC Pittsburgh Project Manager or designee who has signed this report.
PA Lab ID: 02-00416
The test results in this report relate only to the samples as received by the laboratory and will meet all requirements of the methodology, with any exceptions noted. This report shall not be reproduced except in full, without the express written approval of the laboratory. All questions should be directed to the Eurofins Pittsburgh Project Manager.
Authorization
Generated
4/27/2023 4:52 PM
Authorized for release by Carrie L Gamber, Senior Project Manager Carrie.Gamber@et.eurofinsus.com 412 963-2428
Table of Contents Cover Title Page
Data Summaries
Definitions
Case Narrative
Detection Summary
Client Sample Results
Default Detection Limits
QC Sample Results
QC Association
Chronicle
Certification Summary
Method Summary
Sample Summary
Reagent Traceability
COAs
Inorganic Sample Data
Metals Data
Met Cover Page
Met Sample Data
Met QC Data Met ICV/CCV Met Blanks Met ICSA/ICSAB Met LCS/LCSD
Met MDL
Met Linear Ranges
Table of Contents Met Preparation Log
Met Analysis Run Log
Met Internal Standards
Met Prep Data
Met Raw Data
General Chemistry Data
Gen Chem Cover Page
Gen Chem Sample Data
Gen Chem QC Data Gen Chem ICV/CCV Gen Chem Blanks Gen Chem LCS/LCSD
Gen Chem MDL
Gen Chem Preparation Log
Gen Chem Analysis Run Log
Gen Chem Prep Data
Gen Chem Raw Data
Shipping and Receiving Documents
Client Chain of Custody
Sample Receipt Checklist
Definitions/Glossary Job ID: 180-153025-2Client: Battelle
Project/Site: Shrewsberry NJ
Qualifiers
Metals Qualifier Description
^+ Continuing Calibration Verification (CCV) is outside acceptance limits, high biased.
Qualifier
B Compound was found in the blank and sample.
J Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value.
U Indicates the analyte was analyzed for but not detected.
General Chemistry Qualifier Description
U Indicates the analyte was analyzed for but not detected.
Qualifier
Glossary These commonly used abbreviations may or may not be present in this report.
¤ Listed under the "D" column to designate that the result is reported on a dry weight basis
Abbreviation
%R Percent Recovery
CFL Contains Free Liquid
CFU Colony Forming Unit
CNF Contains No Free Liquid
DER Duplicate Error Ratio (normalized absolute difference)
Dil Fac Dilution Factor
DL Detection Limit (DoD/DOE)
DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample
DLC Decision Level Concentration (Radiochemistry)
EDL Estimated Detection Limit (Dioxin)
LOD Limit of Detection (DoD/DOE)
LOQ Limit of Quantitation (DoD/DOE)
MCL EPA recommended "Maximum Contaminant Level"
MDA Minimum Detectable Activity (Radiochemistry)
MDC Minimum Detectable Concentration (Radiochemistry)
MDL Method Detection Limit
ML Minimum Level (Dioxin)
MPN Most Probable Number
MQL Method Quantitation Limit
NC Not Calculated
ND Not Detected at the reporting limit (or MDL or EDL if shown)
NEG Negative / Absent
POS Positive / Present
PQL Practical Quantitation Limit
PRES Presumptive
QC Quality Control
RER Relative Error Ratio (Radiochemistry)
RL Reporting Limit or Requested Limit (Radiochemistry)
RPD Relative Percent Difference, a measure of the relative difference between two points
TEF Toxicity Equivalent Factor (Dioxin)
TEQ Toxicity Equivalent Quotient (Dioxin)
TNTC Too Numerous To Count
CASE NARRATIVE
Client: Battelle
Project: Shrewsberry NJ
Report Number: 180-153025-2
With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.
Calculations are performed before rounding to avoid round-off errors in calculated results.
All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.
RECEIPT
The samples were received on 03/03/2023; the samples arrived in good condition, properly preserved and on ice. The temperatures of the 3 coolers at receipt time were 2.5º C, 2.5º C and 3.3º C.
METALS
Several analytes were detected in method blank MB 180-429890/1-A at levels exceeding the reporting limit. If the associated sample reported a result above the MDL and/or RL, the result has been flagged. ). Associated samples were not re-extracted and/or re-analyzed because results were greater than 10X the value found in the method blank.
Arsenic, Cobalt and Vanadium were detected in method blank MB 180-429890/1-A at levels that were above the method detection limit but below the reporting limit. The values should be considered estimates, and have been flagged. If the associated sample reported a result above the MDL and/or RL, the result has been flagged.
HEXAVALENT CHROMIUM
Samples #20230092 COMPOSITE 4 (180-153025-1) and #20230100 AMENDED COMPOSITE 4 (180-153025-2) required dilution prior to analysis. The reporting limits have been adjusted accordingly.
TRIVALENT CHROMIUM
No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.
Detection Summary
Project/Site: Shrewsberry NJ
Client Sample ID: #20230092 COMPOSITE 4 Lab Sample ID: 180-153025-1
☼Aluminum
RL
9.0 mg/Kg
MDL
6.4
Analyte Result Qualifier Unit Dil Fac D Method Prep Type
Total/NA1B15000 EPA 6020B
☼Arsenic 0.15 mg/Kg0.087 Total/NA137 B EPA 6020B
☼Barium 1.5 mg/Kg0.92 Total/NA146 EPA 6020B
☼Beryllium 0.15 mg/Kg0.11 Total/NA11.6 EPA 6020B
☼Cadmium 0.15 mg/Kg0.084 Total/NA11.4 EPA 6020B
☼Chromium 0.30 mg/Kg0.27 Total/NA181 B EPA 6020B
☼Copper 0.45 mg/Kg0.31 Total/NA190 B EPA 6020B
☼Antimony 0.30 mg/Kg0.16 Total/NA10.82 EPA 6020B
☼Lead 0.15 mg/Kg0.099 Total/NA1150 B EPA 6020B
☼Manganese 0.75 mg/Kg0.65 Total/NA1180 B EPA 6020B
☼Nickel 0.15 mg/Kg0.14 Total/NA132 B EPA 6020B
☼Selenium 0.75 mg/Kg0.18 Total/NA12.4 EPA 6020B
☼Silver 0.15 mg/Kg0.042 Total/NA11.6 EPA 6020B
☼Zinc 2.3 mg/Kg0.73 Total/NA1310 B EPA 6020B
☼Cobalt 0.075 mg/Kg0.054 Total/NA18.2 B EPA 6020B
☼Vanadium 0.15 mg/Kg0.14 Total/NA175 B EPA 6020B
☼Cr (III) 500 ug/Kg210 Total/NA181000 7196A
Client Sample ID: #20230100 AMENDED COMPOSITE 4 Lab Sample ID: 180-153025-2
☼Aluminum
RL
12 mg/Kg
MDL
8.8
Analyte Result Qualifier Unit Dil Fac D Method Prep Type
Total/NA1B13000 EPA 6020B
☼Arsenic 0.21 mg/Kg0.12 Total/NA127 B EPA 6020B
☼Barium 2.1 mg/Kg1.3 Total/NA148 EPA 6020B
☼Beryllium 0.21 mg/Kg0.15 Total/NA11.1 EPA 6020B
☼Cadmium 0.21 mg/Kg0.12 Total/NA10.84 EPA 6020B
☼Chromium 0.41 mg/Kg0.37 Total/NA163 B EPA 6020B
☼Copper 0.62 mg/Kg0.43 Total/NA192 B EPA 6020B
☼Antimony 0.41 mg/Kg0.22 Total/NA10.70 EPA 6020B
☼Lead 0.21 mg/Kg0.14 Total/NA196 B EPA 6020B
☼Manganese 1.0 mg/Kg0.89 Total/NA1180 B EPA 6020B
☼Nickel 0.21 mg/Kg0.19 Total/NA126 B EPA 6020B
☼Selenium 1.0 mg/Kg0.25 Total/NA11.6 EPA 6020B
☼Silver 0.21 mg/Kg0.058 Total/NA10.98 EPA 6020B
☼Zinc 3.1 mg/Kg0.99 Total/NA1270 B EPA 6020B
☼Cobalt 0.10 mg/Kg0.074 Total/NA17.8 B EPA 6020B
☼Vanadium 0.21 mg/Kg0.19 Total/NA154 B EPA 6020B
☼Cr (III) 500 ug/Kg210 Total/NA163000 7196A
Eurofins Pittsburgh
This Detection Summary does not include radiochemical test results.
Client Sample Results
Project/Site: Shrewsberry NJ
Method: SW846 EPA 6020B - Metals (ICP/MS)
Lab Sample ID: 180-153025-1Client Sample ID: #20230092 COMPOSITE 4 Matrix: SedimentDate Collected: 02/28/23 14:53
Percent Solids: 32.9Date Received: 03/03/23 10:05
RL MDL
15000 B 9.0 6.4 mg/Kg ☼ 03/21/23 11:51 04/25/23 16:58 1
Analyte Dil FacAnalyzedPreparedUnit DResult Qualifier
Aluminum
0.15 0.087 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼37 BArsenic
1.5 0.92 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼46Barium
0.15 0.11 mg/Kg 03/21/23 11:51 04/26/23 19:39 1☼1.6Beryllium
0.15 0.084 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼1.4Cadmium
0.30 0.27 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼81 BChromium
0.45 0.31 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼90 BCopper
0.30 0.16 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼0.82Antimony
0.15 0.099 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼150 BLead
0.75 0.65 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼180 BManganese
0.15 0.14 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼32 BNickel
0.75 0.18 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼2.4Selenium
0.15 0.042 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼1.6Silver
2.3 0.73 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼310 BZinc
0.075 0.054 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼8.2 BCobalt
0.15 0.14 mg/Kg 03/21/23 11:51 04/25/23 16:58 1☼75 BVanadium
Project/Site: Shrewsberry NJ
Method: SW846 EPA 6020B - Metals (ICP/MS)
Lab Sample ID: 180-153025-2Client Sample ID: #20230100 AMENDED COMPOSITE 4 Matrix: SedimentDate Collected: 02/28/23 14:53
Percent Solids: 40.4Date Received: 03/03/23 10:05
RL MDL
13000 B 12 8.8 mg/Kg ☼ 03/21/23 11:51 04/25/23 17:01 1
Analyte Dil FacAnalyzedPreparedUnit DResult Qualifier
Aluminum
0.21 0.12 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼27 BArsenic
2.1 1.3 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼48Barium
0.21 0.15 mg/Kg 03/21/23 11:51 04/26/23 19:48 1☼1.1Beryllium
0.21 0.12 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼0.84Cadmium
0.41 0.37 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼63 BChromium
0.62 0.43 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼92 BCopper
0.41 0.22 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼0.70Antimony
0.21 0.14 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼96 BLead
1.0 0.89 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼180 BManganese
0.21 0.19 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼26 BNickel
1.0 0.25 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼1.6Selenium
0.21 0.058 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼0.98Silver
3.1 0.99 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼270 BZinc
0.10 0.074 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼7.8 BCobalt
0.21 0.19 mg/Kg 03/21/23 11:51 04/25/23 17:01 1☼54 BVanadium
Project/Site: Shrewsberry NJ
General Chemistry
Lab Sample ID: 180-153025-1Client Sample ID: #20230092 COMPOSITE 4 Matrix: SedimentDate Collected: 02/28/23 14:53
Date Received: 03/03/23 10:05
RL MDL
81000 500 210 ug/Kg ☼ 04/27/23 06:20 1
Analyte Dil FacAnalyzedPreparedUnit DResult Qualifier
Cr (III) (SW846 7196A)
Project/Site: Shrewsberry NJ
General Chemistry
Lab Sample ID: 180-153025-1Client Sample ID: #20230092 COMPOSITE 4 Matrix: SedimentDate Collected: 02/28/23 14:53
Percent Solids: 32.9Date Received: 03/03/23 10:05
RL MDL
6200 U 6200 3300 ug/Kg ☼ 03/07/23 15:28 03/09/23 12:02 5
Analyte Dil FacAnalyzedPreparedUnit DResult Qualifier
Cr (VI) (SW846 EPA 7196A)
Project/Site: Shrewsberry NJ
General Chemistry
Lab Sample ID: 180-153025-2Client Sample ID: #20230100 AMENDED COMPOSITE 4 Matrix: SedimentDate Collected: 02/28/23 14:53
Date Received: 03/03/23 10:05
RL MDL
63000 500 210 ug/Kg ☼ 04/27/23 06:20 1
Analyte Dil FacAnalyzedPreparedUnit DResult Qualifier
Cr (III) (SW846 7196A)
Project/Site: Shrewsberry NJ
General Chemistry
Lab Sample ID: 180-153025-2Client Sample ID: #20230100 AMENDED COMPOSITE 4 Matrix: SedimentDate Collected: 02/28/23 14:53
Percent Solids: 40.4Date Received: 03/03/23 10:05
RL MDL
5100 U 5100 2700 ug/Kg ☼ 03/07/23 15:28 03/09/23 12:05 5
Analyte Dil FacAnalyzedPreparedUnit DResult Qualifier
Cr (VI) (SW846 EPA 7196A)
Default Detection Limits Client: Battelle Job ID: 180-153025-2 Project/Site: Shrewsberry NJ
Method: EPA 6020B - Metals (ICP/MS) Prep: 3050B
3.0Aluminum mg/Kg
Analyte UnitsMDLRL
2.1
0.10Antimony mg/Kg0.053
0.050Arsenic mg/Kg0.029
0.50Barium mg/Kg0.31
0.050Beryllium mg/Kg0.036
0.050Cadmium mg/Kg0.028
0.10Chromium mg/Kg0.089
0.025Cobalt mg/Kg0.018
0.15Copper mg/Kg0.10
0.050Lead mg/Kg0.033
0.25Manganese mg/Kg0.22
0.050Nickel mg/Kg0.047
0.25Selenium mg/Kg0.061
0.050Silver mg/Kg0.014
0.050Vanadium mg/Kg0.047
0.75Zinc mg/Kg0.24
General Chemistry
500Cr (III) ug/Kg
Analyte UnitsMDLRL
General Chemistry Prep: 3060A
400Cr (VI) ug/Kg
Analyte UnitsMDLRL
QC Sample Results
Project/Site: Shrewsberry NJ
Method: EPA 6020B - Metals (ICP/MS)
Client Sample ID: Method BlankLab Sample ID: MB 180-429890/1-A Matrix: Sediment Prep Type: Total/NA Analysis Batch: 433426 Prep Batch: 429890
RL MDL
Aluminum 14.1 6.0 4.2 mg/Kg 03/21/23 11:51 04/25/23 16:29 1
MB MB
Analyte Dil FacAnalyzedPreparedDUnitResult Qualifier
0.0590 J 0.0580.10 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Arsenic
1.0 U 0.611.0 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Barium
0.10 U ^+ 0.0720.10 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Beryllium
0.10 U 0.0560.10 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Cadmium
0.252 0.180.20 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Chromium
0.363 0.210.30 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Copper
0.20 U 0.110.20 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Antimony
0.176 0.0660.10 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Lead
0.704 0.430.50 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Manganese
0.130 0.0940.10 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Nickel
0.50 U 0.120.50 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Selenium
0.10 U 0.0280.10 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Silver
1.92 0.481.5 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Zinc
0.0440 J 0.0360.050 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Cobalt
0.0979 J 0.0940.10 mg/Kg 03/21/23 11:51 04/25/23 16:29 1Vanadium
Client Sample ID: Method BlankLab Sample ID: MB 180-429890/1-A Matrix: Sediment Prep Type: Total/NA Analysis Batch: 433538 Prep Batch: 429890
RL MDL
Beryllium 0.10 U 0.10 0.072 mg/Kg 03/21/23 11:51 04/26/23 19:16 1
MB MB
Analyte Dil FacAnalyzedPreparedDUnitResult Qualifier
Client Sample ID: Lab Control SampleLab Sample ID: LCS 180-429890/2-A Matrix: Sediment Prep Type: Total/NA Analysis Batch: 433426 Prep Batch: 429890
Aluminum 500 446 mg/Kg 89 80 - 120
Analyte
LCS LCS
DUnitResult Qualifier %Rec
Spike
Added
%Rec
Limits
Arsenic 100 87.0 mg/Kg 87 80 - 120
Barium 100 104 mg/Kg 104 80 - 120
Cadmium 50.0 51.2 mg/Kg 102 80 - 120
Chromium 50.0 51.3 mg/Kg 103 80 - 120
Copper 50.0 52.4 mg/Kg 105 80 - 120
Antimony 25.0 27.0 mg/Kg 108 80 - 120
Lead 50.0 52.2 mg/Kg 104 80 - 120
Manganese 50.0 50.8 mg/Kg 102 80 - 120
Nickel 50.0 52.0 mg/Kg 104 80 - 120
Selenium 100 106 mg/Kg 106 80 - 120
Silver 25.0 24.3 mg/Kg 97 80 - 120
Zinc 25.0 23.7 mg/Kg 95 80 - 120
Cobalt 50.0 52.7 mg/Kg 105 80 - 120
Vanadium 50.0 51.4 mg/Kg 103 80 - 120
QC Sample Results
Project/Site: Shrewsberry NJ
Method: EPA 6020B - Metals (ICP/MS) (Continued)
Client Sample ID: Lab Control SampleLab Sample ID: LCS 180-429890/2-A Matrix: Sediment Prep Type: Total/NA Analysis Batch: 433538 Prep Batch: 429890
Beryllium 50.0 50.9 mg/Kg 102 80 - 120
Analyte
LCS LCS
DUnitResult Qualifier %Rec
Spike
Added
%Rec
Limits
Method: EPA 7196A - Chromium, Hexavalent
Client Sample ID: Method BlankLab Sample ID: MB 180-428416/1-A Matrix: Sediment Prep Type: Total/NA Analysis Batch: 428700 Prep Batch: 428416
RL MDL
Cr (VI) 400 U 400 210 ug/Kg 03/07/23 15:28 03/09/23 11:52 1
MB MB
Analyte Dil FacAnalyzedPreparedDUnitResult Qualifier
Client Sample ID: Lab Control SampleLab Sample ID: LCSI 180-428416/3-A Matrix: Sediment Prep Type: Total/NA Analysis Batch: 428700 Prep Batch: 428416
Cr (VI) 708000 674000 ug/Kg 95 80 - 120
Analyte
LCSI LCSI
DUnitResult Qualifier %Rec
Spike
Added
%Rec
Limits
Client Sample ID: Lab Control SampleLab Sample ID: LCSS 180-428416/2-A Matrix: Sediment Prep Type: Total/NA Analysis Batch: 428700 Prep Batch: 428416
Cr (VI) 20000 21400 ug/Kg 107 80 - 120
Analyte
LCSS LCSS
DUnitResult Qualifier %Rec
Spike
Added
%Rec
Limits
QC Association Summary
Project/Site: Shrewsberry NJ
Metals
Prep Batch: 429890
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Sediment 3050B180-153025-1 #20230092 COMPOSITE 4 Total/NA
Sediment 3050B180-153025-2 #20230100 AMENDED COMPOSITE 4 Total/NA
Sediment 3050BMB 180-429890/1-A Method Blank Total/NA
Sediment 3050BLCS 180-429890/2-A Lab Control Sample Total/NA
Sediment 3050BLCSSRM 180-429890/3-A Lab Control Sample Total/NA
Analysis Batch: 433426
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Sediment EPA 6020B 429890180-153025-1 #20230092 COMPOSITE 4 Total/NA
Sediment EPA 6020B 429890180-153025-2 #20230100 AMENDED COMPOSITE 4 Total/NA
Sediment EPA 6020B 429890MB 180-429890/1-A Method Blank Total/NA
Sediment EPA 6020B 429890LCS 180-429890/2-A Lab Control Sample Total/NA
Sediment EPA 6020B 429890LCSSRM 180-429890/3-A Lab Control Sample Total/NA
Analysis Batch: 433538
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Sediment EPA 6020B 429890180-153025-1 #20230092 COMPOSITE 4 Total/NA
Sediment EPA 6020B 429890180-153025-2 #20230100 AMENDED COMPOSITE 4 Total/NA
Sediment EPA 6020B 429890MB 180-429890/1-A Method Blank Total/NA
Sediment EPA 6020B 429890LCS 180-429890/2-A Lab Control Sample Total/NA
Sediment EPA 6020B 429890LCSSRM 180-429890/3-A Lab Control Sample Total/NA
General Chemistry
Prep Batch: 428416
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Sediment 3060A180-153025-1 #20230092 COMPOSITE 4 Total/NA
Sediment 3060A180-153025-2 #20230100 AMENDED COMPOSITE 4 Total/NA
Sediment 3060AMB 180-428416/1-A Method Blank Total/NA
Sediment 3060ALCSI 180-428416/3-A Lab Control Sample Total/NA
Sediment 3060ALCSS 180-428416/2-A Lab Control Sample Total/NA
Analysis Batch: 428700
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Sediment EPA 7196A 428416180-153025-1 #20230092 COMPOSITE 4 Total/NA
Sediment EPA 7196A 428416180-153025-2 #20230100 AMENDED COMPOSITE 4 Total/NA
Sediment EPA 7196A 428416MB 180-428416/1-A Method Blank Total/NA
Sediment EPA 7196A 428416LCSI 180-428416/3-A Lab Control Sample Total/NA
Sediment EPA 7196A 428416LCSS 180-428416/2-A Lab Control Sample Total/NA
Analysis Batch: 430520
Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch
Sediment 7196A180-153025-1 #20230092 COMPOSITE 4 Total/NA
Sediment 7196A180-153025-2 #20230100 AMENDED COMPOSITE 4 Total/NA
Lab Chronicle
Project/Site: Shrewsberry NJ
Client Sample ID: #20230092 COMPOSITE 4 Lab Sample ID: 180-153025-1 Matrix: SedimentDate Collected: 02/28/23 14:53
Date Received: 03/03/23 10:05
Analysis 7196A RJR04/27/23 06:201 EET PIT430520
Type
Batch
Method
Batch
Prep Type LabAnalystRun
Prepared or Analyzed
Initial
Amount Amount
Final Batch
NumberFactor
Dil
Total/NA
Instrument ID: NOEQUIP
Client Sample ID: #20230092 COMPOSITE 4 Lab Sample ID: 180-153025-1 Matrix: SedimentDate Collected: 02/28/23 14:53
Percent Solids: 32.9Date Received: 03/03/23 10:05
Prep 3050B JBP03/21/23 11:51 EET PIT429890
Type
Batch
Method
Batch
Prep Type LabAnalystRun
Prepared or Analyzed
Initial
Amount Amount
Final Batch
NumberFactor
Dil
Total/NA 1.01 g 50 mL
Analysis EPA 6020B 1 433426 04/25/23 16:58 DSH EET PITTotal/NA
NEMOInstrument ID:
Prep 3050B 429890 03/21/23 11:51 JBP EET PITTotal/NA 1.01 g 50 mL
Analysis EPA 6020B 1 433538 04/26/23 19:39 DSH EET PITTotal/NA
NEMOInstrument ID:
Prep 3060A 428416 03/07/23 15:28 BAC EET PITTotal/NA 2.46 g 100 mL
Analysis EPA 7196A 5 428700 03/09/23 12:02 BAC EET PITTotal/NA 4 mL 4 mL
RAPID-TInstrument ID:
Client Sample ID: #20230100 AMENDED COMPOSITE 4 Lab Sample ID: 180-153025-2 Matrix: SedimentDate Collected: 02/28/23 14:53
Date Received: 03/03/23 10:05
Analysis 7196A RJR04/27/23 06:201 EET PIT430520
Type
Batch
Method
Batch
Prep Type LabAnalystRun
Prepared or Analyzed
Initial
Amount Amount
Final Batch
NumberFactor
Dil
Total/NA
Instrument ID: NOEQUIP
Client Sample ID: #20230100 AMENDED COMPOSITE 4 Lab Sample ID: 180-153025-2 Matrix: SedimentDate Collected: 02/28/23 14:53
Percent Solids: 40.4Date Received: 03/03/23 10:05
Prep 3050B JBP03/21/23 11:51 EET PIT429890
Type
Batch
Method
Batch
Prep Type LabAnalystRun
Prepared or Analyzed
Initial
Amount Amount
Final Batch
NumberFactor
Dil
Total/NA 0.60 g 50 mL
Analysis EPA 6020B 1 433426 04/25/23 17:01 DSH EET PITTotal/NA
NEMOInstrument ID:
Prep 3050B 429890 03/21/23 11:51 JBP EET PITTotal/NA 0.60 g 50 mL
Analysis EPA 6020B 1 433538 04/26/23 19:48 DSH EET PITTotal/NA
NEMOInstrument ID:
Prep 3060A 428416 03/07/23 15:28 BAC EET PITTotal/NA 2.45 g 100 mL
Analysis EPA 7196A 5 428700 03/09/23 12:05 BAC EET PITTotal/NA 4 mL 4 mL
RAPID-TInstrument ID:
Laboratory References:
EET PIT = Eurofins Pittsburgh, 301 Alpha Drive, RIDC Park, Pittsburgh, PA 15238, TEL (412)963-7058
Lab Chronicle
Project/Site: Shrewsberry NJ
Analyst References:
Lab: EET PIT
Batch Type: Prep
BAC = Blase Cindric
JBP = Jack Prothero
Batch Type: Analysis
BAC = Blase Cindric
DSH = David Heakin
RJR = Ron Rosenbaum
Accreditation/Certification Summary
Project/Site: Shrewsberry NJ
Laboratory: Eurofins Pittsburgh Unless otherwise noted, all analytes for this laboratory were covered under each accreditation/certification below.
Authority Program Identification Number Expiration Date
New Jersey NELAP PA005 06-30-23
The following analytes are included in this report, but the laboratory is not certified by the governing authority. This list may include analytes for which the agency does not offer certification.
Analysis Method Prep Method Matrix Analyte
7196A Sediment Cr (III)
New York NELAP 11182 04-01-24
The following analytes are included in this report, but the laboratory is not certified by the governing authority. This list may include analytes for which the agency does not offer certification.
Analysis Method Prep Method Matrix Analyte
7196A Sediment Cr (III)
Method Summary
Project/Site: Shrewsberry NJ
Method Method Description LaboratoryProtocol
SW846EPA 6020B Metals (ICP/MS) EET PIT
SW8467196A Chromium, Trivalent (Colorimetric) EET PIT
SW846EPA 7196A Chromium, Hexavalent EET PIT
SW8463050B Preparation, Metals EET PIT
SW8463060A Alkaline Digestion (Chromium, Hexavalent) EET PIT
Protocol References:
SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates.
Laboratory References:
EET PIT = Eurofins Pittsburgh, 301 Alpha Drive, RIDC Park, Pittsburgh, PA 15238, TEL (412)963-7058
Sample Summary
Project/Site: Shrewsberry NJ
Lab Sample ID Client Sample ID Matrix Collected Received
180-153025-1 #20230092 COMPOSITE 4 Sediment 02/28/23 14:53 03/03/23 10:05
180-153025-2 #20230100 AMENDED COMPOSITE 4 Sediment 02/28/23 14:53 03/03/23 10:05
REAGENT TRACEABILITY SUMMARY
Lab Name:
SDG No.:
Job No.: 180-153025-2Eurofins Pittsburgh
Reagent ID Exp Date Date
Prep Dilutant Used
Reagent Final Volume
Parent Reagent
Reagent ID Volume Added ConcentrationAnalyte
03/07/24 (Purchased Reagent) Aluminum 1000 mg/LInorganic Ventures, Lot U2-MEB730243EUROPITTSP-1_00002 Arsenic 200 mg/L B 250 mg/L Barium 200 mg/L Beryllium 100 mg/L Ca 5000 mg/L Cadmium 100 mg/L Chromium 100 mg/L Cobalt 100 mg/L Copper 100 mg/L Fe 1000 mg/L K 5000 mg/L Lead 100 mg/L Li 100 mg/L Manganese 100 mg/L Mg 5000 mg/L Na 5000 mg/L Nickel 100 mg/L P 100 mg/L Selenium 200 mg/L Silver 50 mg/L Sr 100 mg/L Tl 200 mg/L Vanadium 100 mg/L Zinc 50 mg/L
03/07/24 (Purchased Reagent) Antimony 50 ug/mLInorganic Ventures, Lot U2-MEB730242EUROPITTSP-2_00001 Mo 100 ug/mL Si 200 ug/mL SiO2 428 ug/mL Sn 200 ug/mL Ti 100 ug/mL
03/07/24 (Purchased Reagent) Th 5 ug/mLInorganic Ventures, Lot U2-MEB730241EUROPITTSP-3_00001 U 5 ug/mL
TA-CAL1_00008 Antimony 0.2 ppm1000 mL 2 mL05/25/23 02/25/23MCCV2 uthp_00026 2% Nitric Acid, Lot 5125799
Arsenic 0.2 ppm Barium 0.2 ppm Beryllium 0.2 ppm Cadmium 0.2 ppm Chromium 0.2 ppm Cobalt 0.2 ppm Copper 0.2 ppm Lead 0.2 ppm Manganese 0.2 ppm Nickel 0.2 ppm Selenium 0.2 ppm Vanadium 0.2 ppm
SDG No.:
Job No.: 180-153025-2Eurofins Pittsburgh
Reagent ID Exp Date Date
Prep Dilutant Used
Reagent Final Volume
Parent Reagent
Reagent ID Volume Added ConcentrationAnalyte
Aluminum 50 ppmTA-CAL2_00010 25 mL Silver 0.1 ppmTA-CAL3 REV2_00003 2 mL Zinc 0.1 ppm
01/29/24 (Purchased Reagent) Antimony 100 ppmCPI International, Lot 1208138-1.TA-CAL1_00008 Arsenic 100 ppm Barium 100 ppm Beryllium 100 ppm Cadmium 100 ppm Chromium 100 ppm Cobalt 100 ppm Copper 100 ppm Lead 100 ppm Manganese 100 ppm Nickel 100 ppm Selenium 100 ppm Vanadium 100 ppm
11/30/23 (Purchased Reagent) Aluminum 2000 ppmCPI International, Lot 1208136-1.TA-CAL2_00010 12/31/23 (Purchased Reagent) Silver 50 mg/LCPI International, Lot 10103959-3.TA-CAL3 REV2_00003
Zinc 50 mg/L
MUICPMS-CRI-1_00003 Aluminum 0.03 ppm500 mL 2 mL05/16/23 02/16/23MCRIX A_uthp_00030 2% Nitric Acid, Lot 5125799
Arsenic 0.001 ppm Barium 0.01 ppm Beryllium 0.001 ppm Cadmium 0.001 ppm Chromium 0.002 ppm Cobalt 0.0005 ppm Copper 0.002 ppm Lead 0.001 ppm Manganese 0.005 ppm Nickel 0.001 ppm Selenium 0.005 ppm Silver 0.001 ppm Vanadium 0.001 ppm Zinc 0.005 ppm
MUICPMS-CRI-2_00004 2 mL Antimony 0.002 ppm 04/30/24 (Purchased Reagent) Aluminum 7.5 ppmCPI INTERNATIONAL, Lot 1299722.MUICPMS-CRI-1_00003
Arsenic 0.25 ppm Barium 2.5 ppm Beryllium 0.25 ppm Cadmium 0.25 ppm Chromium 0.5 ppm Cobalt 0.125 ppm Copper 0.5 ppm Lead 0.25 ppm Manganese 1.25 ppm Nickel 0.25 ppm Selenium 1.25 ppm
SDG No.:
Job No.: 180-153025-2Eurofins Pittsburgh
Reagent ID Exp Date Date
Prep Dilutant Used
Reagent Final Volume
Parent Reagent
Reagent ID Volume Added ConcentrationAnalyte
Silver 0.25 ppm Vanadium 0.25 ppm Zinc 1.25 ppm
04/30/24 (Purchased Reagent) Antimony 0.5 ppmCPI INT., Lot 1299723.MUICPMS-CRI-2_00004
M6020ICSA-MIX_00010 Aluminum 100 ppm250 mL 25 mL06/07/23 03/07/23MICSAB A_uthp_00039 2% Nitric Acid, Lot 5125799
Ca 100 ppm Fe 100 ppm K 100 ppm Mg 100 ppm Mo 2 ppm Na 100 ppm P 100 ppm Ti 2 ppm Arsenic 0.02 ppmMICSAB-1_00003 2.5 mL Cadmium 0.02 ppm Chromium 0.02 ppm Cobalt 0.02 ppm Copper 0.02 ppm Manganese 0.022 ppm Nickel 0.02 ppm Silver 0.02 ppm Zinc 0.022 ppm Antimony 0.022 ppmMICSAB-2_00015 0.5 mL B 0.05 ppm Barium 0.028 ppm Beryllium 0.02 ppm Lead 0.02 ppm Li 0.02 ppm Selenium 0.05 ppm Si 0.5 ppm Sn 0.1 ppm Sr 0.02 ppm Tl 0.02 ppm U 0.02 ppm Vanadium 0.02 ppm
MICSAB-3_00002 0.5 mL Th 0.02 ppm 04/30/24 (Purchased Reagent) Aluminum 1000 ppmCPI INT., Lot 1267033-1.M6020ICSA-MIX_00010
Ca 1000 ppm Fe 1000 ppm K 1000 ppm Mg 1000 ppm Mo 20 ppm Na 1000 ppm P 1000 ppm Ti 20 ppm
01/29/24 (Purchased Reagent) Arsenic 2 ug/mLCPI, Lot 1275484.MICSAB-1_00003 Cadmium 2 ug/mL
SDG No.:
Job No.: 180-153025-2Eurofins Pittsburgh
Reagent ID Exp Date Date
Prep Dilutant Used
Reagent Final Volume
Parent Reagent
Reagent ID Volume Added ConcentrationAnalyte
Chromium 2 ug/mL Cobalt 2 ug/mL Copper 2 ug/mL Manganese 2.2 ug/mL Nickel 2 ug/mL Silver 2 ug/mL Zinc 2.2 ug/mL
04/30/24 (Purchased Reagent) Antimony 11 ppmCPI, Lot 1299720.MICSAB-2_00015 B 25 ppm Barium 14 ppm Beryllium 10 ppm Lead 10 ppm Li 10 ppm Selenium 25 ppm Si 250 ppm Sn 50 ppm Sr 10 ppm Tl 10 ppm U 10 ppm Vanadium 10 ppm
09/30/23 (Purchased Reagent) Th 10 ppmCPI, Lot 12133297.MICSAB-3_00002
M6020ICSA-MIX_00010 Aluminum 100 ppm250 mL 25 mL05/16/23 02/16/23MICSAX_00225 2% Nitric Acid, Lot 5125799
Ca 100 ppm Fe 100 ppm K 100 ppm Mg 100 ppm Mo 2 ppm Na 100 ppm P 100 ppm Ti 2 ppm
04/30/24 (Purchased Reagent) Aluminum 1000 ppmCPI INT., Lot 1267033-1.M6020ICSA-MIX_00010 Ca 1000 ppm Fe 1000 ppm K 1000 ppm Mg 1000 ppm Mo 20 ppm Na 1000 ppm P 1000 ppm Ti 20 ppm
MICPMSICV_00031 Aluminum 0.4 mg/L250 mg/L 10 mg/L06/20/23 03/20/23MICVX A_uthp_00022 2% Nitric Acid, Lot 5125799
Antimony 0.08 mg/L Arsenic 0.08 mg/L Barium 0.08 mg/L Beryllium 0.08 mg/L Cadmium 0.08 mg/L
SDG No.:
Job No.: 180-153025-2Eurofins Pittsburgh
Reagent ID Exp Date Date
Prep Dilutant Used
Reagent Final Volume
Parent Reagent
Reagent ID Volume Added ConcentrationAnalyte
Chromium 0.08 mg/L Cobalt 0.08 mg/L Copper 0.08 mg/L Lead 0.08 mg/L Manganese 0.4 mg/L Nickel 0.08 mg/L Selenium 0.08 mg/L Silver 0.08 mg/L Vanadium 0.08 mg/L Zinc 0.08 mg/L
11/30/23 (Purchased Reagent) Aluminum 10 ppmCPI International, Lot 220504.MICPMSICV_00031 Antimony 2 ppm Arsenic 2 ppm Barium 2 ppm Beryllium 2 ppm Cadmium 2 ppm Chromium 2 ppm Cobalt 2 ppm Copper 2 ppm Lead 2 ppm Manganese 10 ppm Nickel 2 ppm Selenium 2 ppm Silver 2 ppm Vanadium 2 ppm Zinc 2 ppm
TA-CAL2_00010 Aluminum 100 ppm250 mL 12.5 mL06/23/23 02/25/23MSTD2X_uthp_00022 2% Nitric Acid, Lot 5125796
Silver 0.2 ppmTA-CAL3 REV2_00003 1 mL Zinc 0.2 ppm
11/30/23 (Purchased Reagent) Aluminum 2000 ppmCPI International, Lot 1208136-1.TA-CAL2_00010 12/31/23 (Purchased Reagent) Silver 50 mg/LCPI International, Lot 10103959-3.TA-CAL3 REV2_00003
Zinc 50 mg/L
TA-CAL1_00010 Antimony 0.4 ppm250 mL 1 mL05/16/23 02/16/23MSTD3X A New_00060 2% Nitric Acid, Lot 5125799
Arsenic 0.4 ppm Barium 0.4 ppm Beryllium 0.4 ppm Cadmium 0.4 ppm Chromium 0.4 ppm Cobalt 0.4 ppm Copper 0.4 ppm Lead 0.4 ppm Manganese 0.4 ppm Nickel 0.4 ppm Selenium 0.4 ppm Vanadium 0.4 ppm
SDG No.:
Job No.: 180-153025-2Eurofins Pittsburgh
Reagent ID Exp Date Date
Prep Dilutant Used
Reagent Final Volume
Parent Reagent
Reagent ID Volume Added ConcentrationAnalyte
07/29/24 (Purchased Reagent) Antimony 100 ppmCPI International, Lot 1321095-1.TA-CAL1_00010 Arsenic 100 ppm Barium 100 ppm Beryllium 100 ppm Cadmium 100 ppm Chromium 100 ppm Cobalt 100 ppm Copper 100 ppm Lead 100 ppm Manganese 100 ppm Nickel 100 ppm Selenium 100 ppm Vanadium 100 ppm
MTH1000_00003 Th 5 mg/L100 mL 0.5 mL08/01/23 02/01/23Th U spike_00028 2% Nitric Acid, Lot 4866773
MU1000_00003 0.5 mL U 5 mg/L 09/23/23 (Purchased Reagent) Th 1000 ppmCPI - International, Lot 1237804-2.MTH1000_00003 09/23/23 (Purchased Reagent) U 1000 ppmCPI International, Lot 1112440-29.MU1000_00003
10/31/24 (Purchased Reagent) Cr (VI) 0.160909 g/gSigma Aldrich, Lot BCBZ6842WCr6InsolSP_00004 Lead (II) Chromate 1 g/g
WCR+6 1000 P_00028 Cr (VI) 49.9976 mg/L200 mL 10 mL05/01/23 11/01/22WCr6S50SP_00090 DI Water, Lot NA Potassium Dichromate 49.9976 mg/L
WK2CrO7P_00018 Cr (VI) 999.953 mg/L250 mL 0.7072 g05/01/23 11/01/22.WCR+6 1000 P_00028 DI Water, Lot NA Potassium Dichromate 999.953 mg/L
10/31/23 (Purchased Reagent) Cr (VI) 0.35349 g/gSTREM CHEMICALS, Lot 35854200..WK2CrO7P_00018 Potassium Dichromate 0.35349 g/g
03/14/23 03/07/23 50 mL WCR+6 1000 P_00028 0.025 mL Cr (VI) 0.499976 mg/LWCRTCR6CCV_00062 05/01/23 11/01/22 250 mL WK2CrO7P_00018 0.7072 g Cr (VI) 999.953 mg/L.WCR+6 1000 P_00028 DI Water, Lot NA 10/31/23 (Purchased Reagent) Cr (VI) 0.35349 g/gSTREM CHEMICALS, Lot 35854200..WK2CrO7P_00018
03/14/23 03/07/23 50 mL WCr1000S_00012 0.025 mL Cr (VI) 0.5 mg/LWCRTCR6ICV_00067 0.25 N H2SO4, Lot 4791891
02/20/24 (Purchased Reagent) Cr (VI) 1000 ppmLabChem, Inc., Lot M032-21.WCr1000S_00012
Reagent
EUROPITTSP-1_00002
1.0 ACCREDITATION / REGISTRATION
INORGANIC VENTURES is accredited to ISO 17034, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General
Requirements for the Competence of Testing and Calibration Laboratories".
Inorganic Ventures is also an ISO 9001 registered manufacturer (QSR Certificate
Number QSR-1034).
Testing Laboratory
Certificate 883.01
Reference Material Producer
Certificate 883.02
2.0 PRODUCT DESCRIPTION
Product Code: Multi Analyte Custom Grade Solution
Catalog Number: EUROPITTSP-1
Lot Number: U2-MEB730243
Matrix: 5% (v/v) HNO3
5 000 µg/mL ea:
Calcium, Potassium, Sodium, Magnesium, 1 000 µg/mL ea:
Iron, Aluminum, 250 µg/mL ea:
Boron, 200 µg/mL ea:
Barium, Arsenic, Selenium, Thallium, 100 µg/mL ea:
Vanadium, Strontium, Manganese, Beryllium, Cadmium, Cobalt, Chromium, Copper, Lithium, Nickel, Phosphorus, Lead, 50 µg/mL ea:
Silver, Zinc
Value / Analyte(s):
3.0 CERTIFIED VALUES AND UNCERTAINTIES
ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE
Aluminum, Al 1 000 ± 4 µg/mL Arsenic, As 200.0 ± 1.6 µg/mL
Barium, Ba 199.9 ± 0.9 µg/mL Beryllium, Be 100.0 ± 0.6 µg/mL
Boron, B 250.0 ± 1.5 µg/mL Cadmium, Cd 100.0 ± 0.4 µg/mL
Calcium, Ca 5 000 ± 22 µg/mL Chromium, Cr 100.0 ± 0.6 µg/mL
Cobalt, Co 100.2 ± 0.5 µg/mL Copper, Cu 100.1 ± 0.4 µg/mL
Iron, Fe 1 000 ± 4 µg/mL Lead, Pb 100.0 ± 0.6 µg/mL
Lithium, Li 100.2 ± 0.4 µg/mL Magnesium, Mg 5 000 ± 23 µg/mL
Manganese, Mn 100.0 ± 0.5 µg/mL Nickel, Ni 100.0 ± 0.5 µg/mL
Phosphorus, P 100.1 ± 0.5 µg/mL Potassium, K 5 000 ± 22 µg/mL
Selenium, Se 200.0 ± 1.3 µg/mL Silver, Ag 50.00 ± 0.22 µg/mL
Sodium, Na 5 000 ± 22 µg/mL Strontium, Sr 100.0 ± 0.4 µg/mL
Thallium, Tl 200.1 ± 1.4 µg/mL Vanadium, V 100.0 ± 0.5 µg/mL
Zinc, Zn 49.85 ± 0.23 µg/mL
Density: 1.101 g/mL (measured at 20 ± 4 ºC)
Assay Information:
METHOD NIST SRM# SRM LOT#ANALYTE
3151ICP Assay 160729Ag
999cVolhard 999cAg
3101aICP Assay 140903Al
928EDTA 928Al
3103aICP Assay 100818As
3107ICP Assay 190605B
3104aICP Assay 140909Ba
Gravimetric See Sec. 4.2Ba
3105aICP Assay 090514Be
3109aICP Assay 130213Ca
928EDTA 928Ca
3108ICP Assay 130116Cd
928EDTA 928Cd
3113ICP Assay 190630Co
928EDTA 928Co
3112aICP Assay 170630Cr
3114ICP Assay 121207Cu
928EDTA 928Cu
3126aICP Assay 140812Fe
928EDTA 928Fe
3141aICP Assay 140813K
Gravimetric See Sec. 4.2K
3129aICP Assay 100714Li
Gravimetric See Sec. 4.2Li
3131aICP Assay 140110Mg
928EDTA 928Mg
3132ICP Assay 050429Mn
928EDTA 928Mn
Traceable to 3152AICP Assay S2-NA700842Na
Gravimetric See Sec. 4.2Na
3136ICP Assay 120619Ni
928EDTA 928Ni
3139aICP Assay 060717P
84LAcidimetric 84LP
3149ICP Assay 100901Se
928EDTA 928Sr
Traceable to 3153aICP Assay K2-SR650985Sr
3158ICP Assay 151215Tl
3165ICP Assay 160906V
928EDTA 928V
3168aICP Assay 120629Zn
928EDTA 928Zn
The following equations are used in the calculation of the certified value and the uncertainty. Reported uncertainties represent expanded uncertainties expressed at approximately the 95% confidence level using a coverage factor of k = 2.
4.0 TRACEABILITY TO NIST
- This product is traceable to NIST via an unbroken chain of comparisons. The uncertainties for each certified value are reported, taking into account the SRM/RM uncertainty error and the measurement, weighing and volume dilution errors. In rare cases where no NIST SRM/RM are available, the term 'in-house std.' is specified.
4.1 Thermometer Calibration
- All analytical balances are calibrated by an accredited calibration laboratory and procedure. The weights used for testing are annually compared to master weights and are traceable to NIST.
4.2 Balance Calibration
- All thermometers are NIST traceable through thermometers that are calibrated by an accredited calibration laboratory.
4.3 Glassware Calibration
- An in-house procedure is used to calibrate all Class A glassware used in the manufacturing and quality control of CRM/RMs.
TRACE METALLIC IMPURITIES (TMI ) DETERMINED BY ICP-MS AND ICP-OES (µg/mL)5.0
N/A
INTENDED USE6.0
6.1 This standard is intended for the calibration of analytical instruments and validation of analytical methods as appropriate. This CRM may be used in connection with EPA Methods 6010, 6020 (all versions), Standard
Methods 3120 B and USP <232> / ICH Q3D.
6.2 For products attaining traceability through Inorganic Ventures’ Primary Certified Reference Materials (PCRM™) see the Limited License to Use PCRM™ in the Inorganic Ventures Terms and Conditions of Sale, https://www.inorganicventures.com/terms-and-conditions-sale. The Terms and Conditions contain information on the use of materials traceable to PCRM™ certified reference materials. This Limited License agreement is especially pertinent for laboratories accredited under ISO:17034.
INSTRUCTIONS FOR THE CORRECT USE OF THIS REFERENCE MATERIAL7.0
7.1 Storage and Handling Recommendations
www.inorganicventures.com/TCT- For more information, visit
- Store between approximately 4° - 30° C while in sealed TCT bag.
- While stored in the sealed TCT bag, transpiration of this CRM/RM is negligible. After opening the sealed TCT bag transpiration of the CRM/RM will occur, resulting in a gradual increase in the analyte concentration(s). It is the responsibility of the user to account for this effect. When the bottle is weighed both before and after being placed in storage, the mass difference observed will be a measure of transpiration mass loss.
- After opening the sealed TCT bag, keep cap tightly sealed when not in use and store between 4° - 24° C to minimize the effects of transpiration. Use at 20° ± 4° C to minimize volumetric dilution error when using the reported density. Do not pipette from the container. Do not return removed aliquots to container.
HAZARDOUS INFORMATION 8.0
- Please refer to the Safety Data Sheet for information regarding this CRM/RM.
HOMOGENEITY9.0
- This solution was mixed according to an in-house procedure and is guaranteed to be homogeneous.
Homogeneity data indicate that the end user should take a minimum sample size of 0.2 mL to assure homogeneity.
QUALITY STANDARD DOCUMENTATION10.0
10.1 ISO 9001 Quality Management System Registration
- QSR Certificate Number QSR-1034
- Chemical Testing - Accredited / A2LA Certificate Number 883.01
10.2 ISO/IEC 17025 "General Requirements for the Competence of Testing and Calibration Laboratories"
- Reference Material Producer - Accredited / A2LA Certificate Number 883.02
10.3 ISO 17034 "General Requirements for the Competence of Reference Material Producers"
Inorganic Ventures, 300 Technology Drive, Christiansburg, Va. 24073, USA; Telephone: 800.669.6799; 540.585.3030, Fax: 540.585.3012; inorganicventures.com;
info@inorganicventures.com
CERTIFICATION, LOT EXPIRATION AND PERIOD OF VALIDITY11.0
11.1 Certification Issue Date
11.2 Lot Expiration Date
- The certification is valid within the measurement uncertainty specified provided the CRM/RM is stored and handled in accordance with instructions given in Sec 7.1. This certification is nullified if instructions in Sec 7.1 are not followed or if the CRM/RM is damaged, contaminated, or otherwise modified.
February 28, 2023
- The lot expiration date reflects the period of time that the stability of a CRM/RM can be supported by long term stability studies conducted on properly stored and handled CRM/RMs. Lot expiration is limited primarily by transpiration (loss of water from the solution) and infrequently by chemical stability.
- February 28, 2028
- The date after which this CRM/RM should not be used.
11.3 Period of Validity
- This CRM/RM should not be used longer than one year (or six months in the case of a 30 mL bottle) from the date of opening the aluminized bag or after the date given in Sec. 11.2, whichever comes first. This is contingent upon the CRM/RM being stored and handled in accordance with the instructions given in Sec. 7.1.
- Sealed TCT Bag Open Date: __________________________
12.0 NAMES AND SIGNATURES OF CERTIFYING OFFICERS
Certificate Approved By:
Paul Gaines
Chairman / Senior Technical Director
Certifying Officer:
Thomas Kozikowski
Manager, Quality Control
EUROPITTSP-2_00001
the Competence of Reference Material Producers" and ISO/IEC 17025, "General
Requirements for the Competence of Testing and Calibration Laboratories".
Inorganic Ventures is also an ISO 9001 registered manufacturer (QSR Certificate
Number QSR-1034).
Testing Laboratory
Certificate 883.01
Reference Material Producer
Certificate 883.02
2.0 PRODUCT DESCRIPTION
Product Code: Multi Analyte Custom Grade Solution
Catalog Number: EUROPITTSP-2
Lot Number: U2-MEB730242
Matrix: 5% (v/v) HNO3
tr. HF
200 µg/mL ea:
Silicon, Tin, 100 µg/mL ea:
Titanium, Molybdenum, 50 µg/mL ea:
Antimony
Value / Analyte(s):
3.0 CERTIFIED VALUES AND UNCERTAINTIES
ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE
Antimony, Sb 50.00 ± 0.40 µg/mL Molybdenum, Mo 100.0 ± 0.4 µg/mL
Silicon, Si 200.0 ± 1.3 µg/mL Tin, Sn 200.0 ± 1.0 µg/mL
Titanium, Ti 100.0 ± 0.6 µg/mL
Density: 1.025 g/mL (measured at 20 ± 4 ºC)
Assay Information:
METHOD NIST SRM# SRM LOT#ANALYTE
3134ICP Assay 130418Mo
Calculated See Sec. 4.2Mo
3102aICP Assay 140911Sb
Traceable to 3150ICP Assay S2-SI702546Si
3161aICP Assay 140917Sn
Calculated See Sec. 4.2Sn
3162aICP Assay 130925Ti
Calculated See Sec. 4.2Ti
The following equations are used in the calculation of the certified value and the uncertainty. Reported uncertainties represent expanded uncertainties expressed at approximately the 95% confidence level using a coverage factor of k = 2.
4.0 TRACEABILITY TO NIST
- This product is traceable to NIST via an unbroken chain of comparisons. The uncertainties for each certified value are reported, taking into account the SRM/RM uncertainty error and the measurement, weighing and volume dilution errors. In rare cases where no NIST SRM/RM are available, the term 'in-house std.' is specified.
4.1 Thermometer Calibration
- All analytical balances are calibrated by an accredited calibration laboratory and procedure. The weights used for testing are annually compared to master weights and are traceable to NIST.
4.2 Balance Calibration
- All thermometers are NIST traceable through thermometers that are calibrated by an accredited calibration laboratory.
4.3 Glassware Calibration
- An in-house procedure is used to calibrate all Class A glassware used in the manufacturing and quality control of CRM/RMs.
TRACE METALLIC IMPURITIES (TMI ) DETERMINED BY ICP-MS AND ICP-OES (µg/mL)5.0
N/A
INTENDED USE6.0
6.1 This standard is intended for the calibration of analytical instruments and validation of analytical methods as appropriate. This CRM may be used in connection with EPA Methods 6010, 6020 (all versions), Standard
Methods 3120 B and USP <232> / ICH Q3D.
6.2 For products attaining traceability through Inorganic Ventures’ Primary Certified Reference Materials (PCRM™) see the Limited License to Use PCRM™ in the Inorganic Ventures Terms and Conditions of Sale, https://www.inorganicventures.com/terms-and-conditions-sale. The Terms and Conditions contain information on the use of materials traceable to PCRM™ certified reference materials. This Limited License agreement is especially pertinent for laboratories accredited under ISO:17034.
INSTRUCTIONS FOR THE CORRECT USE OF THIS REFERENCE MATERIAL7.0
7.1 Storage and Handling Recommendations
www.inorganicventures.com/TCT- For more information, visit
- Store between approximately 4° - 30° C while in sealed TCT bag.
- While stored in the sealed TCT bag, transpiration of this CRM/RM is negligible. After opening the sealed TCT bag transpiration of the CRM/RM will occur, resulting in a gradual increase in the analyte concentration(s). It is the responsibility of the user to account for this effect. When the bottle is weighed both before and after being placed in storage, the mass difference observed will be a measure of transpiration mass loss.
- After opening the sealed TCT bag, keep cap tightly sealed when not in use and store between 4° - 24° C to minimize the effects of transpiration. Use at 20° ± 4° C to minimize volumetric dilution error when using the reported density. Do not pipette from the container. Do not return removed aliquots to container.
HF Note: This standard should not be prepared or stored in glass.
HAZARDOUS INFORMATION 8.0
- Please refer to the Safety Data Sheet for information regarding this CRM/RM.
HOMOGENEITY9.0
- This solution was mixed according to an in-house procedure and is guaranteed to be homogeneous.
Homogeneity data indicate that the end user should take a minimum sample size of 0.2 mL to assure homogeneity.
QUALITY STANDARD DOCUMENTATION10.0
10.1 ISO 9001 Quality Management System Registration
- QSR Certificate Number QSR-1034
- Chemical Testing - Accredited / A2LA Certificate Number 883.01
10.2 ISO/IEC 17025 "General Requirements for the Competence of Testing and Calibration Laboratories"
- Reference Material Producer - Accredited / A2LA Certificate Number 883.02
10.3 ISO 17034 "General Requirements for the Competence of Reference Material Producers"
Inorganic Ventures, 300 Technology Drive, Christiansburg, Va. 24073, USA; Telephone: 800.669.6799; 540.585.3030, Fax: 540.585.3012; inorganicventures.com;
info@inorganicventures.com
CERTIFICATION, LOT EXPIRATION AND PERIOD OF VALIDITY11.0
11.1 Certification Issue Date
11.2 Lot Expiration Date
- The certification is valid within the measurement uncertainty specified provided the CRM/RM is stored and handled in accordance with instructions given in Sec 7.1. This certification is nullified if instructions in Sec 7.1 are not followed or if the CRM/RM is damaged, contaminated, or otherwise modified.
February 28, 2023
- The lot expiration date reflects the period of time that the stability of a CRM/RM can be supported by long term stability studies conducted on properly stored and handled CRM/RMs. Lot expiration is limited primarily by transpiration (loss of water from the solution) and infrequently by chemical stability.
- February 28, 2028
- The date after which this CRM/RM should not be used.
11.3 Period of Validity
- This CRM/RM should not be used longer than one year (or six months in the case of a 30 mL bottle) from the date of opening the aluminized bag or after the date given in Sec. 11.2, whichever comes first. This is contingent upon the CRM/RM being stored and handled in accordance with the instructions given in Sec. 7.1.
- Sealed TCT Bag Open Date: __________________________
12.0 NAMES AND SIGNATURES OF CERTIFYING OFFICERS
Certificate Approved By:
Paul Gaines
Chairman / Senior Technical Director
Certifying Officer:
Thomas Kozikowski
Manager, Quality Control
EUROPITTSP-3_00001
the Competence of Reference Material Producers" and ISO/IEC 17025, "General
Requirements for the Competence of Testing and Calibration Laboratories".
Inorganic Ventures is also an ISO 9001 registered manufacturer (QSR Certificate
Number QSR-1034).
Testing Laboratory
Certificate 883.01
Reference Material Producer
Certificate 883.02
2.0 PRODUCT DESCRIPTION
Product Code: Multi Analyte Custom Grade Solution
Catalog Number: EUROPITTSP-3
Lot Number: U2-MEB730241
Matrix: 5% (v/v) HNO3
5 µg/mL ea:
Thorium, Uranium
Value / Analyte(s):
3.0 CERTIFIED VALUES AND UNCERTAINTIES
ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE
Thorium, Th 5.002 ± 0.026 µg/mL Uranium, U 5.002 ± 0.025 µg/mL
Density: 1.026 g/mL (measured at 20 ± 4 ºC)
Assay Information:
METHOD NIST SRM# SRM LOT#ANALYTE
928EDTA 928Th
Calculated See Sec. 4.2Th
3164ICP Assay 080521U
Calculated See Sec. 4.2U
The following equations are used in the calculation of the certified value and the uncertainty. Reported uncertainties represent expanded uncertainties expressed at approximately the 95% confidence level using a coverage factor of k = 2.
Certified Abundance:
IV's Certified Abundance
Isotope Atom %
Uranium 238U
Uranium 235U
99.8 ± 0.1
0.19 ± 0.05
4.0 TRACEABILITY TO NIST
- This product is traceable to NIST via an unbroken chain of comparisons. The uncertainties for each certified value are reported, taking into account the SRM/RM uncertainty error and the measurement, weighing and volume dilution errors. In rare cases where no NIST SRM/RM are available, the term 'in-house std.' is specified.
4.1 Thermometer Calibration
- All analytical balances are calibrated by an accredited calibration laboratory and procedure. The weights used for testing are annually compared to master weights and are traceable to NIST.
4.2 Balance Calibration
- All thermometers are NIST traceable through thermometers that are calibrated by an accredited calibration laboratory.
4.3 Glassware Calibration
- An in-house procedure is used to calibrate all Class A glassware used in the manufacturing and quality control of CRM/RMs.
TRACE METALLIC IMPURITIES (TMI ) DETERMINED BY ICP-MS AND ICP-OES (µg/mL)5.0
N/A
INTENDED USE6.0
6.1 This standard is intended for the calibration of analytical instruments and validation of analytical methods as appropriate. This CRM may be used in connection with EPA Methods 6010, 6020 (all versions), Standard
Methods 3120 B and USP <232> / ICH Q3D.
6.2 For products attaining traceability through Inorganic Ventures’ Primary Certified Reference Materials (PCRM™) see the Limited License to Use PCRM™ in the Inorganic Ventures Terms and Conditions of Sale, https://www.inorganicventures.com/terms-and-conditions-sale. The Terms and Conditions contain information on the use of materials traceable to PCRM™ certified reference materials. This Limited License agreement is especially pertinent for laboratories accredited under ISO:17034.
INSTRUCTIONS FOR THE CORRECT USE OF THIS REFERENCE MATERIAL7.0
7.1 Storage and Handling Recommendations
www.inorganicventures.com/TCT- For more information, visit
- Store between approximately 4° - 30° C while in sealed TCT bag.
- While stored in the sealed TCT bag, transpiration of this CRM/RM is negligible. After opening the sealed TCT bag transpiration of the CRM/RM will occur, resulting in a gradual increase in the analyte concentration(s). It is the responsibility of the user to account for this effect. When the bottle is weighed both before and after being placed in storage, the mass difference observed will be a measure of transpiration mass loss.
- After opening the sealed TCT bag, keep cap tightly sealed when not in use and store between 4° - 24° C to minimize the effects of transpiration. Use at 20° ± 4° C to minimize volumetric dilution error when using the reported density. Do not pipette from the container. Do not return removed aliquots to container.
HAZARDOUS INFORMATION 8.0
- Please refer to the Safety Data Sheet for information regarding this CRM/RM.
HOMOGENEITY9.0
- This solution was mixed according to an in-house procedure and is guaranteed to be homogeneous.
Homogeneity data indicate that the end user should take a minimum sample size of 0.2 mL to assure homogeneity.
QUALITY STANDARD DOCUMENTATION10.0
10.1 ISO 9001 Quality Management System Registration
- QSR Certificate Number QSR-1034
- Chemical Testing - Accredited / A2LA Certificate Number 883.01
10.2 ISO/IEC 17025 "General Requirements for the Competence of Testing and Calibration Laboratories"
- Reference Material Producer - Accredited / A2LA Certificate Number 883.02
10.3 ISO 17034 "General Requirements for the Competence of Reference Material Producers"
Inorganic Ventures, 300 Technology Drive, Christiansburg, Va. 24073, USA; Telephone: 800.669.6799; 540.585.3030, Fax: 540.585.3012;…