J004 - Annex C - CEAC Building Plans_v2.pdf

PDF 6 MB Posted

Attached to
USMA Wind Tunnel Federal contract opportunity
Solicitation number
W91RUS24R0025
Issued by
Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground

About this file

This document appears to be a set of drawings related to a design build requirement for a Wind Tunnel at the United States Military Academy (USMA). The drawings provide detailed plans for the Cyber & Engineering Academic Center and Parking Structure, including equipment layouts, reflected ceiling plans, electrical power plans, and utility plans. Key details include:

The USMA has a design build requirement for a Wind Tunnel that meets or exceeds the Program of Instruction (POI) objectives for their engineering program. The solicitation number is W91RUS24R0025. The drawings provide detailed information on the construction of the Cyber & Engineering Academic Center, which will house the Wind Tunnel. This includes specifications for an Aeronautical Laboratory, manufacturing support spaces, electronics labs, and other related facilities. The drawings cover architectural, electrical, and utility plans for the overall facility.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

11 12 13 13.5

B

A

ELECTRONICS

LAB

EC-250

PROJECT BASED

LEARNING

EC-238

THERMO

SUPPORT

EC-242

PROJECT BASED

LEARNING

EC-240

TELECOM

EC-234

ELEC

EC-232

MANUFACTURING

SUPPORT

EC-236B

AERONAUTICAL

EC-246

THERMODYNAMICS

EC-244

MANUFACTURING

EC-236A

CORRIDOR

#5

EC-5C2

CORRIDOR

#6

EC-6C2

A1

A-712

A1

A-712

E C

-2 A

.1

EC-232.1

EC-234.1

E C

-2 .1

E C

-2 .1

EC-243.1

E C

-2 .1

E C

-2 .1

E C

-2 B

.1 M30 M3M3M3

G3ABS

6"

0 G3ABSG3ABSG3ABS

M30 M3M3M3

G3ABS

6"

0 G3ABSG3ABSG3ABS

G3ABS

6"

0 G3ABSG3ABSG3ABS

G3AB0 G3ABG3ABG3AB

6"

G3ABS

6"

0 G3ABSG3ABSG3ABS

M3A0 M3AM3AM3A

M30 M3M3M3

M32 M3M3M3 M32 M3M3M3

M32 M3M3M3

M30 M3M3M3 M32 M3M3M3

/A1 A-112E

E C

-2 .1

E C

-2 .1

M3A0 M3AM3AM3A

CORRIDOR #2

EC-2C2

/A1 A-112J

ROOF, SEE A-102F

/A1 A-112J/A1 A-112H

R P

-2 .2

A-412F.20

C1 A-412F.30

C1

4' - 10" 2' - 2"

2' - 0"

2' - 0"

4"

/8

/8

POTENTIAL FUTURE

BRIDGE CONNECTION;

KEEP CLEAR OF

OBSTRUCTIONS

E C

-2 .1

E C

-2 .1

D.1

C.5

G3ABS

6"

0 G3ABSG3ABSG3ABS

S3S2 S3SS3SS3S

4"

S32 S3S3S3 4"

F2S0 F2SF2SF2S

S3S2 S3SS3SS3S

4"

A-412F.10

D1

EC-232B.1 A-505

C7

A-723 A5

E7

A-519

SIM

A1

A-518

SIM

R P

-2 .2

32' - 0" 32' - 0" 16' - 0" 16' - 0"

C

G3AB0 G3ABG3ABG3AB

6"

/4

EC-244.2

E C

-2 .1

A-722A5

G7AB0 G7ABG7ABG7AB

6"

12' - 5 1/2"

/4

F30 F3F3F3 6"

F30 F3F3F3 7/8"

M3A0 M3AM3AM3A

F30 F3F3F3 6"

/2

2C2.132C2.11 2C2.122C2.10

246.2

246.1

6"

A-506

E1 A-506

E4

A-506

E7

M

IN

244.2244.3

F3A0 F3AF3AF3A

6"

F3A0 F3AF3AF3A

6"

246.4

F2S0 F2SF2SF2S

6"

F2S0 F2SF2SF2S

6"

A-715

F1SIM

A-412E.21

D1

A-412E.21

A1

A-505

C7

SIM

A-506

E1

A-504

E7

SIM

A-508

A4

A-508

C4

A-508

A1

A-508

C1

A-508

A7 A-508

C7

ALIGN

ALIGN

G3ABS0 G3ABSG3ABSG3ABS

M3A0 M3AM3AM3A

SIM

17' - 10"

3' - 4"

246.3

246.5 244.1244.4

A-003

G

SIM

F20 F2F2F2

M3A0 M3AM3AM3AM3A0 M3AM3AM3A

A-412J.12

D4

CENTER DOOR ON

CORRIDOR #6 EC-6C2

A1

A-533

TYP

A1

A-533

TYP

A1

A-533

TYP

A1

A-533

TYP

A1

A-533

TYP

A1

A-533

TYP

A1

A-533

TYP

M30 M3M3M3

M3A0 M3AM3AM3A

M3A0 M3AM3AM3A

M3A0 M3AM3AM3A

M3A0 M3AM3AM3A

M3A0 M3AM3AM3A

M3A0 M3AM3AM3A

M3A0 M3AM3AM3A

M3A0 M3AM3AM3A

F60 F6F6F6 7/8"

F2S0 F2SF2SF2S

7/8"

F3A0 F3AF3AF3A

6"

F3S0 F3SF3SF3S

7/8"

F2S0 F2SF2SF2S

6"

E W

S

EWS

CR CR CR

FD

FD

CO

A-619

F1

TYP

M1

M2

M1 M1

M1 M1

CR

M32 M3M3M3

ALIGN

M30 M3M3M3 4"

M30 M3M3M3

A-515

C8

A-515

A8

1' - 1" 3' - 11"

A-616

F3

SIM

F30 F3F3F3

F30 F3F3F3

F30 F3F3F3

F30 F3F3F3

F60 F6F6F6 F60 F6F6F6

M30 M3M3M3 4"

M30 M3M3M3 4"

M30 M3M3M3 4"

MECHANICAL

SHAFT

8' - 0" 3' - 1" 10' - 3" 13' - 9" 8' - 6" 13' - 0" 6' - 2" 7' - 7" 8' - 0" 7' - 0" 13' - 6" 12' - 2" 6' - 4"

2' - 0"

S3S2 S3SS3SS3S

4"

11' - 4" 10" 10' - 4"

EA SIDE

EA SIDE

CMU WALL

CENTERED

ON GRID B

/2

F3ABS

6"

0 F3ABSF3ABSF3ABS

R A

T E

D M

A S

O N

R Y

W A

L L

T O

C L O

F

ALIGN

/2

/2

E X

T E

R I O

R

T Y

P A

T

E X

T E

R I O

R

T Y

P A

T

EXTERIOR

6" TYP AT

G3ABS

6"

0 G3ABSG3ABSG3ABS

C L

R

CR

CR

CR CR

CRCR

GENERAL NOTES

1. SEE A-101 TO A-105 FOR EXTERIOR ARCHITECTURE PLANS AND

SEE A-200 SERIES FOR EXTERIOR ELEVATIONS, ENVELOPE TAGS,

AND CALLOUTS.

2. SEE A-400 SERIES FOR 1/4" PLANS AND ELEVATIONS.

3. SEE A-600 SERIES FOR PARTITION TYPES AND FIRE RATINGS.

4. SEE A-610 SERIES FOR INTERIOR DOOR SCHEDULE AND DETAILS,

AND INTERIOR WINDOW SCHEDULE & DETAILS.

5. SEE A-620 SERIES FOR RETRACTABLE PARTITION SCHEDULE AND

DETAILS, AND BIFOLD DOOR SCHEDULE AND DETAILS.

6. SEE I-000 AND I-100 SERIES FOR FINISH SCHEDULE AND

MATERIALS.

7. SEE STRUCTURAL PLANS FOR EDGE OF SLAB.

8. COORDINATE ALL EDGE OF SLAB GLASS GUARDRAIL AND WALL

EXTENTS WITH EDGE OF SLAB PLANS, ARCHITECTURAL FLOOR

PLANS, AND DETAILS. FIELD VERIFY OPENINGS PRIOR TO

SYSTEM COMPONENT FABRICATION AND/OR INSTALLATION.

9. NEW UL RATED WALLS SHALL BE ERECTED BY HOURLY RATING

PRIORITY IN DESCENDING ORDER AND SHALL BE ERECTED PRIOR

TO NON-RATED WALLS. UL RATED WALLS INTERSECTING

EXTERIOR WALLS SHALL BE EXTENDED THROUGH TO THE

EXTERIOR SHEATHING. REMOVE EXTERIOR WALL AS REQUIRED

TO PROPERLY INSTALL AND REPAIR IN KIND.

10. NEW WALLS SHALL BE ERECTED AS INDICATED AND PER DIVISION

04 SECTION "UNIT MASONRY" AND 09 SECTION “DRYWALL

SYSTEMS".

11. BUILDING MECHANICAL, ELECTRICAL, PLUMBING,

TELECOMMUNICATIONS, FIRE SAFETY, AND AUDIO-VISUAL

DEVICES, FIXTURES, PANELS, JUNCTION BOXES, RECEPTACLE

BOXES, AND EQUIPMENT SHALL BE INSTALLED IN WALLS SO ONLY

THE DEVICE, FACE PLATE, RECEPTACLES, FIXTURE OR

EQUIPMENT REQUIRING REGULAR USER INTERFACE IS EXPOSED.

NO PIPE, DUCT, CONDUIT, WIRE, JUNCTION BOXES, RECEPTACLE

BOXES OR OTHER SUCH ELEMENT SHALL BE EXPOSED.

12. BUILDING MECHANICAL, ELECTRICAL, PLUMBING,

TELECOMMUNICATIONS, FIRE SAFETY, AND AUDIO-VISUAL

DEVICES, FIXTURES, PANELS, AND EQUIPMENT SHALL BE

INSTALLED IN FINISHED CEILINGS (DRYWALL, ACT, WOOD PANEL,

ETC) SUCH THAT ONLY THE USER INTERFACE DEVICE, FIXTURE

OR EQUIPMENT IS EXPOSED. NO PIPE, DUCT, CONDUIT, WIRE,

CONNECTION BOXES, DRIVERS, OR OTHER SUCH ELEMENT

SHALL BE EXPOSED ON FINISHED FACE OF CEILING.

13. CONDUITS, DISCONNECTS, RECEPTACLES, SPECIAL VALVES, AND

FIXTURE FOR UTILITES SERVING USER SUPPLIED EQUIPMENT IN

ALL TEACHING SPACES SHALL BE SURFACE MOUNTED ON CMU

WALLS AND RECESSED MOUNTED IN DRYWALLS.

14. ALL EXTERIOR DOOR TAGS ARE SHOWN ON SHEET A-101.

15. ALL CORRIDORS TO HAVE SPECIAL WALL PROTECTION AS

INDICATED BY SUFFIX "S" IN PARTITION SCHEDULE EXCEPT FOR

FURRED WALL ALONG EAST FACADE.

16. NOT USED.

17. PROVIDE REINFORCING BLOCKING AS REQUIRED PER SHEET

A-603 FOR ALL WALL MOUNTED DEVICES AND WALL HUNG

FURNITURE, ETC.

18. SEE A-001 FOR EXPOSED STRUCT STEEL LEVEL OF FINISH.

19. SEE SHEET A-402 FOR M# MOUNTING HEIGHTS AND DETAILS.

20. SEE SHEET A-516 FOR RADIANT FLOOR MANIFOLD DETAILS.

RAISED ACCESS FLOOR - SEE SHEET

A-518 AND A-519 FOR TYPICAL DETAILS,

SEE STRUCTURAL DRAWINGS FOR

STRUCTURAL SLAB DETAILS AND SEE

INTERIOR DRAWINGS FOR EXTENT.

LEGEND

EXTERIOR ROOF PLAN EXTENT

REF EXTERIOR DWGS

SEE FIN SCHED FOR APPLIED FIN SUCH AS CT, VINYL FABRIC,

PANELING, ETC.

STANDARD CMU SHALL BE 8" (NOM) THK UNO. NON-STANDARD

CMU THK ARE INDICATED AS FOLLOWS:

WHERE MFR'S HT LIMITATIONS ARE EXCEEDED DUE TO FIELD

CONDITIONS, USE HEAVIER GAUGE STUDS IN ACCORDANCE W/

MFR'S RECOMMENDATIONS.

ALL ACOUSTICAL STUD PARTITIONS WITH GWB ON EACH SIDE

(G3A/G3AB/G3ABS/G7AB) MUST BE TAPED AND ACOUSTICALLY

SEALED ON BOTH SIDES. COORDINATE WITH INSTALLATION OF

ADJACENT WALLS TO ENSURE STUD WALLS ARE PROPERLY

SEALED ON EACH SIDE.

FIRE RATED PTN'S ARE IDENTIFIED BY KEY & POCHE AS

FOLLOWS:

2 M3

1.

2.

3.

4.

5.

6"

NEW PARTITONS

NONRATED

1 HR FIRE RATED

2 HR FIRE RATED

EXISTING PARTITONS

NONRATED

EXISTING PARTITONS WHEN

RATING IS REQUIRED

SMOKE BARRIER

1 HR SMOKE BARRIER

2 HR SMOKE BARRIER

1 HR FIRE RATED

2 HR FIRE RATED

SMOKE BARRIER

1 HR SMOKE BARRIER

2 HR SMOKE BARRIER

GENERAL PARTITION NOTES:

04 8 16268

SCALE: 1/8" = 1'-0"

SECTOR FKEY PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

A-112F

S E

C O

N D

F L O

O R

P L A

N

S E

C T

O R

F

/8 th

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

S J

T W

E

C

S D

,E C

,V D

F ,P

F ,N

H

E C

B K

J

K

E C

L B

Y

E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR PLAN - SECTOR F

jko Cloud

SL5

SDd

S

J

J

J

J

J

PC

J

A-412F.31

C1

13 13.5

B

A

A-412F.31

AERONAUTICAL

EC-246

20-27

20-26

20-28

FC1-48 FC1-48 FC1-48

WC3-24

R

P -2

.2

A2

A-536

A-412F.31 E6

E1

C6

1' - 11 5/8"

M# EXTENT

13 13.5

B

A

EQ 35' - 0" EQ

E Q

E Q

TYP

3' - 6"

T Y

P

D8

A-622

+/- 8' - 9" 7' - 0" TYP 7' - 0" 7' - 0" 5' - 5"

E Q

E Q

D1

A-533

D1

A-533

D1

A-533

D1

A-533

A-529

C1

TYP

EQ EQ

D5

A-529

TYP

FURNITURE (SHOWN FOR REF ONLY)

CASEWORK AND MILLWORK

(SPEC # 06 20 00, 06 41 16, & 12 31 00)

LABORATORY EQUIP & FUMEHOODS

(SPEC # 11 53 00). CLEAR FLOOR AREA

SHOWN DASHED WHERE REQ.

FLOOR CLEARANCE

#### EQUIPMENT TAG

SMART BOARD AND SHORT

THROW PROJECTOR

RAISED ACCESS FLOOR - SEE SHEET

A-518 AND A-519 FOR TYPICAL DETAILS,

SEE STRUCTURAL DRAWINGS FOR

STRUCTURAL SLAB DETAILS AND SEE

INTERIOR DRAWINGS FOR EXTENT.

TV MONITOR

FLOOR PLAN SYMBOLS

JUNCTION BOX

ELECTRICAL SYMBOLS - SEE DWG E-002

FIRE ALARM SYMBOLS - SEE DWG FA001

RECEPTACLE

MOTOR | MOTOR CONTROL

PUSH BUTTON

J

TELEPHONE

TELECOM SYMBOLS - SEE DWG T-001

LIGHT SWITCH

S x

DATA

FIRE PULL STATIONF

ARCHITECTURAL SYMBOLS

GOGGLE CABINET; SEE A-535

WC3-24

INTERIOR SYMBOLS - SEE I-130 SERIES DWGS

AUDIOVISUAL SYMBOLS - SEE TA DWGS

CARD READER

LINEAR SUSPENDED

ACOUSTICAL BAFFLES

CEILING SYMBOLS

ARCHITECTURAL SYMBOLS

DIFFUSER - SEE HVAC DWGS

RETURN/EXHAUST GRILLE

PENDANT LUMINAIRE

ELECTRICAL SYMBOLS - SEE DWG E-002

MECHANICAL DUCTWORK SYMBOLS - SEE DWG M-002

RECESSED LINEAR

RECEPTACLE

JUNCTION BOXJ

DATA

TELECOM SYMBOLS - SEE DWG T-001

WALL CLOCKC

CLG MTD SPEAKER

STRUT GRID SYSTEM

NOTE: REFER TO A-120 SERIES FOR COMPREHENSIVE CEILING TYPE LEGEND

02 4 8134

SCALE: 1/4" = 1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

A-412F.30

A E

R O

N A

U T

IC

A

L

E Q

U

IP

M E

N T

P L A

N

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

S J

T W

E

C

S D

,E C

,V D

F ,P

F ,N

H

E C

B K

J

K

E C

L B

Y

E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

SCALE: 1/4" = 1'-0"A-412F.30

REF SHEET: A-112F

SECOND FLOOR AERONAUTICAL - ENLARGED PLANC1

SCALE: 1/4" = 1'-0"A-412F.30

REF SHEET: A-122F

SECOND FLOOR AERONAUTICAL - REFLECTED CEILING PLANC6

KEY PLAN

20-28 FLOW VISUALIZATION TABLE AERONAUTICAL CME001855 1 -- -- X X -- -- -- 120 10 1 -- X -- -- -- -- -- -- -- -- -- X -- X -- --

20-27 HELICOPTER SUPPLY AND CONTROLS AERONAUTICAL CME001857 1 -- -- X X -- -- -- 120 20 1 -- X -- -- -- -- -- -- -- -- -- X -- X -- --

20-26 HELICOPTER TEST STAND AERONAUTICAL CME001856 1 -- -- X X -- -- -- 208 25 1 -- -- X -- -- -- -- -- -- -- -- X -- X -- --

B

IM

I D

E Q

U

IP

N A

M E

R O

O M

N A

M E

U S

M A

I D

Q U

A N

T

IT

Y

N E

W

N E

W

M A

T C

H

E X

IS

T

E X

IS

T

F L

O O

R

W O

R K

S U

R F

A C

E

F L

O O

R

W A

L L

V O

L T

A G

E

A M

P E

R E

P H

A S

E k W

R E

C E

P T

A C

L E

H A

R D

W

IR

E D

L A

N

E X

H A

U S

T

M A

K E

-U P

A

IR

C O

M P

R E

S S

E D

A

IR

C O

L D

H O

T

D R

A

IN

C O

N T

R A

C T

O R

G O

V E

R N

M E

N T

C O

N T

R A

C T

O R

G O

V E

R N

M E

N T

N O

N -F

IX

E

D

F

IX

E D

P O

W E

R

C O

N N

E C

T

IO

N

T Y

P E

D A

T A

A U

T O

M A

T

D U

C T

W O

R K

G A

S

W A

T E

R

D R

A

IN

F U

R N

IS

H

E D

B Y

IN

S

T A

L L

E D

B Y

G O

V E

R N

M E

N T

F U

N D

IN

G

S O

U R

C E

GENERAL

ELECTRICITY & DATA HVAC PLUMBING PROCUREMENT

REMARKS

11 12 13 13.5

B

A

ELECTRONICS

LAB

EC-250

PROJECT BASED

LEARNING

EC-238

THERMO

SUPPORT

EC-242

PROJECT BASED

LEARNING

EC-240

MANUFACTURING

SUPPORT

EC-236B

AERONAUTICAL

EC-246

THERMODYNAMICS

EC-244

MANUFACTURING

EC-236A

CORRIDOR

#5

EC-5C2

CORRIDOR

#6

EC-6C2

10' - 0"A1

9' - 0"A19' - 0"A1

9' - 7"A5

9' - 7"A5

/A1 A-122E

/A1 A-122J

/A1 A-122J/A1 A-122H

10' - 0"G10' - 0"G

RETRACTABLE

PARTITION

RETRACTABLE PARTITION

CORRIDOR #2

EC-2C2

D.1

C.5

A7

A-520

SIM

AERONAUTICAL

EC-246

EQ 6' - 0" EQ

T Y

P

/2

EQ 6' - 0" EQ

C

T Y

P

9' - 7"A2

A-412F.20

D5

A-412F.30

C6

SG 10'-0"SG 10'-0"

SG 10'-0"

13' - 0"G

SG 10'-0"

13' - 0"G

A-412F.11

D1

A-412E.21

D4

A-412E.21

A4

32' - 0" 32' - 0" 16' - 0" 16' - 0"

9' - 6"G

/2

/2

E Q

E Q

E Q

E Q

EQ EQ

E Q

E Q

9' - 6"G

A7

A-520

SIM

TYP

10' - 3" 1' - 6" 1' - 9 3/4"

/4

3' - 1"

TYP

8' - 0"

EQ 22' - 0" EQ

T Y

P

G30 G3G3G3G30 G3G3G3

G30 G3G3G3G30 G3G3G3

/2

/2

8' - 1 5/8"G

8' - 1 5/8"G 8' - 1 5/8"G

8' - 1 5/8"G

8' - 1 5/8"G

8' - 1 5/8"G

A-520

E1

SG 10'-0"

E5

A-616

8' - 0"G

A2

A-520

A7

A-520

SIM

A2

A-520

A2

A-520

C1

A-520

SIM

2'-0" x 2'-0" ACT

CLG; TYPE A1

GWB or PLASTER CEILING or SOFFIT

2'-0" x 4'-0" RECESSED 4'-0" x 7" WALL MTD

PENDANT MTD STRIP LIGHT

PENDANT MTD

INDUSTRIAL LIGHT

RECESSED DOWNLIGHT

WALL WASHER

CEILING MTD EXIT LIGHT, UNO

SMOKE DETECTOR

DIFFUSER - SEE HVAC DWGS

LINEAR DIFFUSER

RETURN/EXHAUST GRILLE

CEILING ACCESS PANEL

CEILING TYPE LEGEND

CEILING TYPE CEILING HEIGHT

1. ALL CEILINGS ACOUSTICAL CEILING TILE AT 8'-0" UNO.

2. ALL OTHER CEILING LABELED AS FOLLOWS:

WOOD LOOK

CEILING SYSTEM

RETURN AIR SLOT;

2" UNO

CLOCKC

A1 8'-0"

PENDANT LUMINAIRE

STRUT GRID SYSTEM

RECESSED

PERIMETER LIGHT

LINEAR SUSPENDED

ACOUSTICAL

BAFFLES

STUDENT COLLAB DECORATIVE PENDANT

4TH FLR (ADD ALT #03) DECORATIVE PENDANT

BRIDGE TO MAHAN (ADD ALT #01)

DECORATIVE PENDANT

CLG MTD SPEAKER

WALL MTD SPEAKER

DATA CLG OUTLET

1'-0" x 3'-6" ACT

CLG; TYPE A2

1'-0" x 6'-0" ACT

CLG; TYPE A5

3. ALL CEILING GRIDS SHALL BE CENTERED ON ROOM/SPACE UNO.

4. SEE A-400 SERIES FOR 1/4" REFLECTED CEILING PLANS.

5. SEE A-520 SERIES FOR CLG DTLS.

6. ALL FIXTURES, DIFFUSERS, GRILLS, SPRINKLER HEADS, SPEAKERS

OR OTHER DEVICES SHALL BE LOCATED IN THE CENTER OF A CEILING

TILE OR THE CENTER OF A PANEL INSCRIBED ON A TILE, UNO.

7. CENTER ALL INDUSTRIAL PENDANT FIXTURES IN ROOM UNO.

8. COORDINATE PROJECTOR LOCATIONS WITH FINAL PROJECTOR

MANUFACTURER.

9. SPRAY ALL EXPOSED STEEL WITH FIREPROOFING, UNLESS

INDICATED ON DWGS A-004.1 & A-004.2, TO RECEIVE INTUMESCENT

COATING.

10. FOR EXTENT OF ACOUSTICAL SPRAY CELLULOSE CEILING

TREATMENT SEE INTERIOR DRAWINGS.

11. ALL OVERHEAD ARCHITECTURAL FEATURES OVER 31LBS MUST BE

MOUNTED SO THAT THEY RESIST FORCES OF 0.5 TIMES THE

COMPONENT WEIGHT IN ANY HORIZONTAL DIRECTION AND 1.5 TIMES

THE COMPONENT WEIGHT IN THE DOWNWARD DIRECTION.

12. ACCESS PANELS ARE TO BE PROVIDED AS NEEDED IN ALL

INACCESSIBLE CEILINGS.

13. SEE A-001 FOR EXPOSED STRUCT STEEL LEVEL OF FINISH.

A ACOUSTICAL CEILING TILE

EP EXISTING PLASTER, TO BE

PTD

EX EXISTING

G GWB, PAINTED

NC NO CEILING

P PLASTER

S1B 1HR RATED FIRE

BARRIER SHAFTWALL

S2 2HR RATED

SHAFTWALL CEILING

SG STRUT GRID SYSTEM

XC SPECIALTY CEILING

CABLE TRAY

SNORKEL

OCCUPANCY SENSOR

SEE FIRE PROTECTION DWGS FOR EQUIPMENT SPECIFICS

SEE HVAC DWGS FOR EQUIPMENT SPECIFICS

SEE IT DWGS FOR EQUIPMENT SPECIFICS

SEE ELEC DWGS FOR FIXTURE SPECIFICS

RECESSED LINEAR PENDANT MOUNTED

LIGHT

04 8 16268

SCALE: 1/8" = 1'-0"

SECTOR FKEY PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

A-122F

S E

C O

N D

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

S E

C T

O R

F

/8 th

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

S J

T W

E

C

S D

,E C

,V D

F ,P

F ,N

H

E C

B K

J

K

E C

L B

Y

E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

SCALE: 1/8" = 1'-0"A1

SECOND FLOOR RCP - SECTOR F

STOP

S T

O P

STOP

FF 163.15

CYBER & ENGINEERING ACADEMIC CENTER

MAIN ELEC. ROOM

EC-142A

EMERGENCY

ELEC. ROOM

EC-142B

PADMOUNT XFMR. T1

WITH SELECTOR SWITCH

EMERGENCY

GENERATOR EG-1

REFER TO DETAIL 1/E501

REFER

TO DETAIL

2/E501

UE

UE

FIRE PUMP

ROOM

REFER TO DETAIL 8/E501

LOT FULL SIGN

LOOP DETECTORS FOR

VEHICLE COUNTING SYSTEM

PARKING ACCESS

GATE ARM PROVIDE STUB

UP CONDUITS 2" ABOVE

TOP OF ENTRY GATE

CONCRETE FOUNDATION

(TYP FOR 2)

GUARD HOUSE

PANEL AP-EL-G

UE

UE

ELECTRICAL JUNCTION BOX

FOR CARD READER, ARM GATES,

AND LOOP DETECTORS.

UE

TO CONTROL BOX IN

GUARD HOUSE - REFER

TO TELECOM DRAWINGS

FOR FURTHER

INFORMATION

AP-EL-G-11

SEE DWG.

NOTE 1

UE

UE

PARKING ACCESS

GATE ARM

LOOP DETECTOR TO

ACTIVATE GATE SYSTEM

LOOP DETECTOR TO

ACTIVATE GATE SYSTEM

EXISTING MH-4

UE

MH-4B MH-4C

UE

UE

MH-4D

MH-4E

UE

UE

E1

E1

E1

E1

E1E1

E1E1

E1 E1

E4E4

E5

REFER TO DETAIL

1/E500 (TYPICAL)

ENTRY GATE ARM

CONTROLLERS

TO CONTROL BOX IN

GUARD HOUSE - REFER TO

TELECOM DRAWINGS FOR

FURTHER INFORMATION

UE

AP-EL-G-8,10

SECURITY WEDGE

BARRIER REFER TO

CIVIL DRAWINGS FOR

EXACT LOCATION

STUB OUT 3/4" CONDUIT

BELOW GRADE FOR LOOP

SENSOR (TYP FOR 2)

AP-EL-G-7

AP-EL-G-9

UE

E5

REFER TO DETAIL 2/E501

FUTURE PADMOUNT XFMR.

FOR WIND TUNNEL

CAP UNDERGROUND

DUCTBANK AT FUTURE

TRANSFORMER LOCATION

STUB UP 12" AFG AND CAP

DUCTBANK AT FUTURE

WIND TUNNEL LOCATION

2#10 & #10G, 3/4"C

PROVIDE (2) 4" CONDUIT IN

CONCRETE DUCTBANK FOR

FUTURE TRANSFORMER.

PORTION OF DUCT BANK TO BE

BORED. REFER TO DRAWING CU-102

FOR ADDITIONAL INFORMATION.

SEE DWG.

NOTE 2

E2

E2

E3

E3

MH-4A

SEE DWG.

NOTE 3

UE

TO DAVIS

CHILLER

PLANT

FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS, REFER TO

DRAWINGS E-001 AND E-002.

THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL

EXISTING UNDERGROUND UTILITIES, SERVICES, ETC. TAKE SPECIFIC

CARE WHEN PERFORMING UNDERGROUND WORK AT AND AROUND

EXISTING UNDERGROUND SERVICES.

THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL EXCAVATION,

TRENCHING AND BACKFILL, INCLUDING SHORING, SHEETING,

PUMPING, GRADING, BARRICADING AND ALL OTHER RELATED WORK

NECESSARY FOR THE INSTALLATION OF ELECTRICAL WORK.

EXCAVATION SHALL BE PERFORMED ON AN UNCLASSIFIED BASIS

AND SHALL INCLUDE REMOVAL OF MATERIALS ENCOUNTERED.

TRENCHES SHALL BE OF SUFFICIENT DEPTH TO ALLOW ADEQUATE

COVER OVER RACEWAYS.

BOTTOMS OF TRENCHES SHALL BE INSTRUMENT GRADED IN

DIRECTION OF FLOW. EARTH SHALL BE SCOOPED OUT SO

RACEWAYS WILL HAVE SOLID BEARINGS ON UNDISTURBED EARTH.

WHERE TRENCHES RUN UNDER WALL FOOTINGS OR COME WITHIN

A 2 TO 1 SLOPE FROM THE BOTTOM OF WALL OR COLUMN

FOOTINGS, BACKFILL WITH LEAN CONCRETE TO A POINT AT OR

ABOVE THE BOTTOM OF WALL OR COLUMN FOOTING. WHERE

TRENCHES MUST BE EXCAVATED IN ROCK A 6" LAYER OF CRUSHED

STONE OR GRAVEL SHALL BE PLACED IN TRENCH TO SUPPORT

RACEWAYS. TRENCHES SHALL BE OF SUFFICIENT DEPTH TO

INSTALL CUSHIONING LAYER.

GENERAL NOTES:

1.

2.

3.

4.

5.

6.

BACKFILL SHALL BE MADE WITH CLEAN EARTH FREE OF ROCKS,

FROZEN EARTH, DEBRIS OR OTHER FOREIGN MATERIAL. DEPOSIT

BACKFILL IN UNIFORM LAYERS NOT OVER 6" THICK. TAMP EACH

LAYER BEFORE APPLYING NEXT LAYER. CINDERS IN BACKFILL ARE

PROHIBITED.

REPAIR STREETS, PAVEMENTS, LAWNS, CURBS AND OTHER

FINISHED SURFACES DAMAGED BY EXCAVATION AND RESTORE

SAME TO ORIGINAL CONDITION.

LOCATIONS OF SERVICES AND THEIR TERMINATIONS ARE

DIAGRAMMATIC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

DETERMINING TERMINATION POINTS AND PROVIDING ALL SERVICES

FROM SITE DISTRIBUTION SOURCES AS REQUIRED.

FULLY COORDINATE INSTALLATION, WIRING AND CONNECTION OF

SERVICE AND DISTRIBUTION SYSTEMS WITH THE GOVERNMENT,

DPW, CITY LIGHT AND POWER, AND ALL CONTRACTORS.

THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH CITY

LIGHT AND POWER: INFORM THEM OF THE PROPOSED WORK;

OBTAIN THEIR APPROVAL BEFORE BEGINNING WORK; COMPLY WITH

THEIR STANDARDS FOR DETAIL OF INSTALLATION AND MATERIALS

USED

REFER TO CIVIL ENGINEERING DRAWINGS FOR EXACT LOCATION OF

EQUIPMENT AND MANHOLES, ETC.

7.

8.

9.

10.

11.

12.

THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR

COORDINATING ALL WORK REQUIRED BY CITY LIGHT AND POWER

AND SHALL HAVE SERVICES AVAILABLE WHEN REQUIRED BY THE

CONSTRUCTION SCHEDULE. ALL WORK PERFORMED BY CITY LIGHT

AND POWER, BOTH FOR TEMPORARY AND PERMANENT POWER,

WILL BE BILLED DIRECTLY TO THE GOVERNMENT AND IS SHOWN

FOR REFERENCE ONLY.

TRANSFORMER AND GENERATOR CONCRETE PADS SHALL BE

PROVIDED BY THE ELECTRICAL CONTRACTOR.

13.

14.

SCALE: 3" = 1'-0"

1/21/4

KEY PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

ES-100

E L E

C T

R

IC

A L S

IT

E

P L A

N

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

D V

-E C

D V

-E C

R G

-E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

SCALE: 1" = 30'-0"1

ELECTRICAL SITE PLAN

FOR EACH CONTROLLER PROVIDE 2#10 & #10G - ROUTE BOTH

CIRCUITS WITHIN (1) 1" CONDUIT BELOW GRADE TO GUARD

HOUSE. CONNECT EACH CIRCUIT TO ITS OWN DEDICATED

20AT/1P CIRCUIT BREAKER IN PANEL AP-EL-G.

PROVIDE (2) 1-1/4" CONDUITS STUBBED AND CAPPED 12" AFG

FROM 2ND FLOOR AERONAUTICAL LAB EC-246.

PROVIDE (1) 1" CONDUIT WITHIN CHILLED WATER TRENCH FOR

MECHANICAL CONTROLS FROM CEAC TO DAVIS CHILLER PLANT.

REFER TO DRAWING CU-102 FOR EXACT LOCATION OF CHILLED

WATER LINE.

DRAWING NOTES:

PARKING LOT GATE WIRING:

1. PROVIDE BRANCH CIRCUIT WIRING CONTROL WIRING AND

DISCONNECT SWITCHES AS SHOWN AND/OR AS REQUIRED.

2. PROVIDE REQUIRED CONTROL WIRING, CONDUIT AND

CONNECTIONS BETWEEN CONTROL UNIT ENCLOSURES AND

ELECTRICALLY OPERATED GATES.

3. PROVIDE WIRING, CONDUIT, AND CONNECTIONS REQUIRED FOR

CARD READERS AND/OR INDUCTIVE LOOP DETECTION FOR

OPERATION OF COMPLETE GATE SYSTEM. ALSO, PROVIDE WIRING,

CONDUIT, AND CONNECTIONS FROM CONTROL UNIT TO GUARD

STATION SHACK FOR REMOTE OPERATION AND/OR DETECTION OF

ILLEGAL ENTRY OR MALFUNCTION OF SYSTEM.

4. PARKING GATE SYSTEM MANUFACTURER WILL PROVIDE SHOP

DRAWINGS OF ALL EQUIPMENT AND WIRING TO BE INSTALLED; ALL

WORK SHALL COMPLY WITH MANUFACTURER'S REQUIREMENTS AND

DETAILS OF INSTALLATION AND MATERIALS USED.

Polygon

J

VFD

VFD VFD

J

J

10 11 12 13 13.5 15

A

EMERGENCY

GENERATOR 'EG-1'

PADMOUNT XFMR 'T1'

WITH SELECTOR SWITCH

WP

WP

WP

BLUE LIGHT SECURITY

SYSTEM (BELOW GRADE)

HEAVY EQUIPMENT PAD

SEE DETAIL 6/E-501

XFMR EQUIPMENT PAD

SEE DETAIL 7/E-500

1A-35

1A-341A-32 1A-32

GEF

GEF

WP

PP-NH-1

REFER TO

SLD E-603

WP

PP-NH-1

REFER TO

SLD E-603

WP

PP-NH-1

REFER TO

SLD E-603

DC

SEE DWG.

NOTE 3

WPWP

WP

1A-21,23 1A-25

1A-22,24

WPWP

WP

1A-26 1A-26

1A-27,29

WP

1A-28

WP

WP

WP

1A-30

1A-30

1A-31,33

SEE DWG.

NOTE 1

SEE DWG.

NOTE 2

1A-34

50A, CARGO TRAILER

CHARGER NEMA 14-50R

FUTURE FMR

EQUIPMENT PAD

SEE DETAIL 7/E-500 FUTURE 500KVA XFMR

FOR WIND TUNNEL

GROUND CONNECTION

TO GENERATOR - SEE

DWG. EP601

1J-33

1J-35,37

GROUND CONNECTION

TO SERVICE XFMR - SEE

DWG. EP601

HEAVY EQUIPMENT PAD

SEE DETAIL 6/E-501

WP

1A-28

WP

1A-28

SEE DWG.

NOTE 1

14 14.7

GENERATOR BATTERY

CHARGER

BLOCK HEATER

1. FOR GENERAL NOTES, ABBREVIATIONS, SCHEDULES, AND

SYMBOLS, REFER TO DRAWINGS E-001, E-002 & E-003.

2. COORDINATE DEVICE LOCATIONS WITH FLOOR PLANS,

CASEWORK, MILLWORK, AND FURNITURE ELEVATIONS.

REFER TO ARCHITECTURAL DETAILS AND ELEVATIONS

FOR ADDITIONAL INFORMATION. NOTIFY ARCHITECT OF

ANY DISCREPANCIES PRIOR TO ROUGH-IN.

3. REFER DETAIL 8/E-502 FOR CIRCUITING REQUIREMENTS OF AIR

VOLUME CONTROL BOXES, ASSOCIATED REHEAT COIL

CONTROL VALVES, AIR VALVES, SMOKE AND COMBINATION

FIRE/SMOKE DAMPERS.

4. REFER TO FIRE PROTECTION OR PLUMBING DRAWINGS FOR

LOCATIONS AND QUANTITIES OF MONITORED FIRE PROTECTION

SYSTEM VALVES, WATER FLOW SWITCHES AND ELECTRIC

BELLS.

6. UNLESS OTHERWISE NOTED, PROVIDE THE FOLLOWING WIRE

SIZES FOR 20A, 120V BRANCH CIRCUIT LENGTHS IN ORDER TO

LIMIT VOLTAGE DROP TO LESS THAN 3%:

A. LESS THAN 90 FEET PROVIDE 2#12 & #12G, 3/4"C.

B. MORE THAN 90 FEET BUT LESS THAN 150 FEET PROVIDE

2#10 & #10G, 3/4"C.

C. MORE THAN 150 FEET PROVIDE 2#8 & #8G, 3/4"C.

7. REFER TO DRAWINGS E-611 TO E-622 FOR PANELBOARD SCHEDULES.

8. NUMERICAL DESIGNATION BESIDE A RECEPTACLE INDICATES THE

BRANCH CIRCUIT BREAKER NUMBER AT THE PANELBOARD. REFER

TO ELECTRICAL PANEL DESIGNATION KEY FOR MORE INFORMATION.

GENERAL NOTES:

9. UNLESS OTHERWISE NOTED, ALL SPECIAL RECEPTACLES/SPECIAL

RECEPTACLE CORD REELS ARE TYPE NEMA 6-20R, 208V-1Ø.

5. DO NOT WIRE GFCI TYPE RECEPTACLES IN A THROUGH-

FEED FASHION.

10. PROVIDE LABELING AT EACH RECEPTACLE INDICATING

DESIGNATED PANEL AND CIRCUIT NUMBER.

04 8 16268

SCALE: 1/8" = 1'-0"

KEY PLAN SECTOR CKEY PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

EP-111C

E L E

C T

R

IC

A L P

O W

E R

P L A

N

F

IR

S T

F L O

O R

S

E C

T O

R C

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

D V

-E C

D V

-E C

R G

-E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

SCALE: 1/8" = 1'-0"1

ELECTRICAL POWER PLAN - FIRST FLOOR - SECTOR C

EP111FEP111E

E P

B

REFER TO DRAWING ES-100

FOR DUCTBANK LAYOUTS

ELECTRICAL PANEL DESIGNATION KEY

TAG PANEL NAME LOCATION SHEET #

TYPICAL DEVICE

1A-##

PANEL TAG (REFER TO

SCHEDULE BELOW)

CIRCUIT NUMBER

1A AP-NL-M-2 EC-142A EP111F

PROVIDE EATON POWER PEDESTAL TYPE 'CHU8N8NKGS' OR

APPROVED EQUAL WITH SPECIFIED RECEPTACLES.

PROVIDE EATON POWER PEDESTAL TYPE 'CHU7S' OR APPROVED

EQUAL WITH SPECIFIED RECEPTACLES.

PROVIDE EATON POWER PEDESTAL TYPE 'CHU1G7N7NS' OR

APPROVED EQUAL WITH SPECIFIED RECEPTACLES.

DRAWING NOTES:

1J AP-NL-M-1 EC-142A EP111F

3"7-1/2"3"

UNDISTURBED EARTH

SEE SPECIFICATIONS

TYPICAL 4" CDT.

SEE SPECIFICATION

3- #5 TOP & BOT.

4000PSI

CONCRETE

#3 AT 18 O.C.

17-1/2"

TOP SHALL BE SPRINKLED

WITH RED DYE

E4 CONDUIT SCHEDULE

1- FIRE PUMP POWER

2- SPARE, PULLWIRE ONLY

FINISHED GRADE

YELLOW LINE MARKER AS SPECIFIED

18" BELOW GRADE, ENTIRE WIDTH,

OF DUCT BANK

54" MIN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

E-501

D E

T A

IL

S

E

L E

C T

R

IC

A L

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

D V

-E C

D V

-E C

R G

-E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

7-1/2"7-1/2" 3"3"

10976

7-1/2"

-1

/2

3"3"

7-1/2"

-1

/2

40"

-1 /2

17-1/2"

-1 /2

Z

IG

-Z A

G

'-0

M

A X

DIRECT BURIAL

CONDUIT DUCTBANK

SEE DUCTBANK DETAIL FOR

ACTUAL DEPTH AND WIDTH

ZIG-ZAG YELLOW WARNING

TAPE OVER CONDUIT DUCTBANK

FOR IT'S ENTIRE LENGTH

REFER TO SITE PLAN

SIDES OF TRENCH

4" RIGID STEEL

CONDUIT. 48"

RADIUS MINIMUM.

REFER TO MFR. SHOP

DRAWINGS FOR EXACT

LOCATION.

CONDUIT COUPLING OR

TRANSITION FITTING AS REQUIRED

CRUSHED

STONE

FINISHED FLOOR

SLAB

CONCRETE PAD

FINISHED INSTALLATION OF

CONDUIT STUB UP

INCLUDING BUSHING SHALL

NOT EXCEED 3" ABOVE

FINISHED CONCRETE

SWITCHBOARD

ENCLOSURE, SEE FLOOR

PLANS AND DETAILS

#3 AT 18" O.C.

3- #5 TOP & BOT.

4000PSI CONCRETE

1-#5 HORIZ. EACH FACE

UNDISTURBED EARTH

SEE SPECIFICATIONS

TYPICAL 4"CDT.

SEE SPECIFICATION

5'-0"

MIN.

C O

N C

R E

T E

S

ID

E W

A L

K

P L A

N T

IN

G

A R

E A

M A

C A

D A

M R

O A

D W

A Y

M A

C A

D A

M R

O A

D W

A Y

TYPICAL DIRECT BURIAL CABLE

OR PVC CONDUIT AS NOTED ON

PLANS; NORMALLY MINIMUM

18"/24" BELOW GRADE

5'-0"

MIN.

SCHEDULE 40

PVC CDT.

TRAFFIC

ISLAND

MACADAM

ROADWAY

3" CONCRETE

ENVELOPE

C O

N C

R E

T E

S

ID

E W

A L

K

P L A

N T

IN

G

A R

E A

M A

C A

D A

M R

O A

D W

A Y

M A

C A

D A

M R

O A

D W

A Y

FINISHED GRADE

YELLOW LINE MARKER AS SPECIFIED

18" BELOW GRADE, ENTIRE WIDTH,

OF DUCT BANK

E2 CONDUIT SCHEDULE

1- ACTIVE, 480V FEED TO SWBD. HSB-1

2- ACTIVE, 480V FEED TO SWBD. HSB-1

3- ACTIVE, 480V FEED TO SWBD. HSB-1

6- ACTIVE, 480V FEED TO SWBD. HSB-1

7- ACTIVE, 480V FEED TO SWBD. HSB-1

8- ACTIVE, 480V FEED TO SWBD. HSB-1

3- #5 TOP & BOT.

4000PSI CONCRETE

UNDISTURBED EARTH

SEE SPECIFICATIONS

4"CDT. (TYP.) SEE

SPECIFICATION

E3 CONDUIT SCHEDULE

1- ATS START WIRING

2- GEN. BATTERY CHARGER

4- GENERATOR POWER

3- GENERATOR HEATER

#3 AT 18" O.C.

54" MIN

FINISHED GRADE

YELLOW LINE MARKER AS SPECIFIED

18" BELOW GRADE, ENTIRE WIDTH,

OF DUCT BANK

4- ACTIVE, 480V FEED TO SWBD. HSB-1 9- SPARE

1. PROVIDE A MINIMUM OF 36" OF CRUSHED GRAVEL AROUND ENTIRE PAD AT 8" IN DEPTH.

REFER TO XFMR MANUFACTURER FOR OIL CAPACITY TO DETERMINE VOLUME OF GRAVEL BED.

2. DEPTH WILL VARY FOR CONDUIT PENETRATION. MINIMUM DEPTH SHALL BE 36". INCREASE

DEPTH FOR CONDUIT PENETRATIONS.

NOTES:

LOWEST CONDUIT

CRUSHED

GRAVEL

#4 AT 12 EA. WAY

EA. FACE

#4 AT 12 TOP &

BOT. EA. WAY

4000 P.S.I. CONCRETE

ANCHOR BOLTS PER

MANUFACTURER'S

REQUIREMENTS.

EDGE OF TRANSFORMER

M

IN

2"10"

C L R

"GRADE

M

IN

EXTEND BELOW

FROST LINE OR

54" MIN.

4"

C L R

POST INSTALLED

ANCHOR - SEE NOTE 1.

4000 P.S.I.

CONCRETE

1. POST INSTALLED ANCHOR TO BE DRILLED INTO TOP OF EQUIPMENT PAD. ANCHOR

TYPE (EXPANSION OR ADHESIVE), DIAMETER, LENGTH, EMBEDMENT, QUANTITY

AND LOCATION PER MANUFACTURER AND SEISMIC REQUIREMENTS.

2. REINFORCEMENT, ETC. INDICATED APPLIES ONLY FOR EQUIPMENT NOT REQUIRED

TO BE SEISMICALLY RESTRAINED. WHERE EQUIPMENT IS REQUIRED TO BE

SEISMICALLY RESTRAINED (REFER TO SECTION 26 05 48), OBTAIN PAD DESIGN

REQUIREMENTS FROM MANUFACTURER TO CONFIRM MASS REQUIREMENTS.

3. INCREASE AS REQUIRED FOR SEISMICALLY RESTRAINED EQUIPMENT.

NOTE:

MINIMUM MASS OF

CONCRETE 1.5 TIMES

EQUIPMENT WEIGHT.

MINUMUM 18".

SEE NOTE 2.

PAD SHALL BE PLACED ON MINIMUM 4"

CRUSHED STONE SUBBASE. SUBSOIL BELOW

PAD TO BE PREPARED AS REQUIRED TO

SUSTAIN A MINIMUM ALLOWABLE PRESSURE

OF 1500 PSF VERIFIED IN THE FIELD BY A

GEOTECHNICAL ENGINEER HIRED BY OWNER.

6" MIN.

SEE NOTE 3.

FINISH

GRADE

LC BOLTSET DIMENSION

FOR MINIMUM 6" TO EDGE

OF EQUIPMENT

FRAME. SEE NOTE 3.

1" x 1" CHAMFER ON

ALL VERTICAL &

HORIZONTAL EDGES

#4@12" ON CENTER, BOTH

WAYS TOP & BOTTOM,

HOOKED. SEE NOTE 2.

10" 2"

6" MIN.

LOWEST

CONDUIT

C L R

EXTEND DOWN

TO FROSTLINE.

(MINIMUM 3').

N.T.S.1

DUCTBANK DETAIL - E2

N.T.S.2

DUCTBANK DETAIL - E3, E5

N.T.S.3

DIRECT BURIAL SERVICES UNDER ROADWAY

N.T.S.4

UNDERGROUND DUCTBANK MARKER

N.T.S.5

EXTERIOR OIL FILLED TRANSFORMER PAD

N.T.S.6

EXTERIOR HEAVY EQUIPMENT PAD

N.T.S.7

CONDUIT SERVICE ENTRANCE

N.T.S.8

DUCTBANK DETAIL - E4

3. VERIFY REQUIREMENTS WITH CITY LIGHT AND POWER PRIOR TO INSTALLATION.

E5 CONDUIT SCHEDULE

1- SPARE, PULLWIRE ONLY (FUTURE WIND TUNNEL)

2- SPARE, PULLWIRE ONLY (FUTURE WIND TUNNEL)

4- SPARE, PULLWIRE ONLY

3- SPARE, PULLWIRE ONLY

54" MIN

7-1/2"

5- ACTIVE, 480V FEED TO SWBD. HSB-1 10- SPARE

1" x 1" CHAMFER ON

ALL VERTICAL &

HORIZONTAL EDGES

NEW MANHOLE MH-9EXISTING MANHOLE MH-4

13.8KV, 3Ø, 1200A,

LOAD-OPERABLE

MANUAL SELECTOR

SWITCH INTEGRAL TO

XFMR T1

3#1/0 (15kV) WITH CONCENTRIC

NEUTRAL INSTALLED IN

[2 OF 3-5"C.] IN CONCRETE

ENCASED UNDERGROUND

DUCTBANK E1.

LA

15KV

XFMR T1

65/55°C RISE

2000/2240KVA, 3Ø, 60HZ

13.8KV - 480Y/277V

Z = 5.73% a bc c b a

100AT

100AF

LSIG

30AT

100AF

LSIG

100AT

100AF

LSIG 2P

800AT

800AF

LSIG

1200AT

1200AF

LSIG

800AT

800AF

LSIG

P A

N E

L A

P -N

L -M

-1 MAIN ELEC.

ROOM EC-142A

W

A

L

W

A

L

ATS-

LS

ATS-

EM

ATS-

FA

MECH

PNL.

ROOF

MECH

PNL.

GAR.

PNL.

W

W

A

L

W

A

L

W

W

W

A

L

SPD

60AT

100AF

LSIG

SWITCHBOARD

"HSB-1" MAIN ELEC. ROOM EC-142A

3W125

65 KAIC MIN.

600AF

600AT

ST

ELECTRONIC

METERING

TO SUBSTATION B-PMS1

3000A, 480Y/277V BUS

INCOMING TRANSITION SECTION

SEPARATE FIRE PUMP TAP SECTION

SEE DRAWING

NOTE 1

(3)

GENERAL NOTES:

1. REFER TO DRAWING E-003 FOR FEEDER IDENTIFICATION SCHEDULE.

2. FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS, REFER TO DRAWINGS E-001 AND E-002.

3. ALL ELECTRICAL EQUIPMENT AND WIRING, SHOWN IN A LIGHT LINE, IS EXISTING TO REMAIN.

4. UNLESS OTHERWISE NOTED, ALL CIRCUIT BREAKERS, MOTOR CIRCUIT PROTECTORS (MCP)

AND/OR SWITCHES ARE THREE (3) POLE. UNLESS OTHERWISE NOTED, ALL MOTOR STARTERS

SHALL BE NEMA SIZE ONE (1).

5. JUNCTION AND PULL BOXES ARE NOT NECESSARILY SHOWN ON THIS DRAWING AND SHALL BE

PROVIDED WHERE NECESSARY AND SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL

CODE ARTICLE 314.28 AND INSTALLED WHERE REQUIRED.

6. ALL SHORT CIRCUIT INTERRUPTING RATINGS SHOWN, WHETHER A.I.C OR M.V.A. I.C. ARE

CALCULATED RMS SYMMETRICAL VALUES AT THE LINE TERMINALS OF THE EQUIPMENT, WITH

THE EXCEPTION OF 10,000 A.I.C. VALUES. THE WITHSTAND SHORT CIRCUIT CURRENT RATINGS

OF PROTECTIVE DEVICES, TRANSFER SWITCHES AND BUS BRACINGS SHALL BE EQUAL TO OR

GREATER THAN THE VALUES INDICATED.

7. ALL MOTOR CIRCUIT PROTECTOR (MCP) AMPACITIES ARE CONTINUOUS RATING AMPACITIES.

8. OVERCURRENT PROTECTION DEVICES FOR THE LIFE SAFETY / LEGALLY REQUIRED STANDBY

SYSTEMS INDICATED ON THE SINGLE LINE DIAGRAM(S) ARE INTENDED TO BE PART OF A

SELECTIVELY COORDINATED SYSTEM IN ACCORDANCE WITH THE SPECIFICATION SECTION

26 28 01.00 10. THE SYSTEM SHOWN IS DESIGNED TO BE SELECTIVELY COORDINATED WITH THE

BASIS OF DESIGN MANUFACTURER, SQUARE D COMPANY. ALL 'APPROVED EQUAL'

MANUFACTURERS SHALL MEET THESE REQUIREMENTS. A COORDINATION STUDY, IN

ACCORDANCE WITH SPECIFICATION SECTION 26 28 01.00 10, IS REQUIRED TO DEMONSTRATE

SELECTIVE COORDINATION, PRIOR TO APPROVAL AND RELEASE OF EQUIPMENT FOR

FABRICATION.

TO FIRE PUMP

CONTROLLER -

SEE DWG. E-604

SEE DWG.

E-604

SEE DWG.

E-604

SEE DWG.

E-604

SEE DWG.

E-603

SEE DWG.

E-603

SEE DWG.

E-604

100AT

100AF

LSIG

225AT

225AF

LSIG

ST

F.A.

CLASS J

225A

400A ST

F.A.

CLASS J

ELEVATOR

CONTROLLER

VFD

FE-1

FREIGHT

ELEVATOR 1

ST

F.A.

CLASS J

100A

100A ST

F.A.

30 KAIC MIN

ELEVATOR

CONTROLLER

VFD

PE-1

PASSENGER

ELEVATOR 1

BY ELEV.

MFR.

W

W

SEE DWG.

NOTE 2

100AT

100AF

LSIG

3W200TAL

250AT

400AF

LSIG

DRAWING NOTES:

1 PROVIDE 24VDC CONTROL WIRING TO "FIREMAN KILL" SWITCH.

ACTIVATION OF EPO SWITCH TO SHUNT TRIP OPEN THE MAIN

CIRCUIT BREAKER.

2 ELEVATOR CIRCUIT BREAKER AND FUSE SIZE TO BE COORDINATED

WITH APPROVED ELEVATOR SHOP DRAWING.

3 PROVIDE 24VDC CONTROL WIRING IN CONDUIT TO FIRE ALARM

CONTROL RELAY IN ELEVATOR MACHINE ROOM.

4 PROVIDE SHARK 200 POWER METER, OR APPROVED EQUAL.

CONNECT TO DPW BASE WIDE CONTROL SYSTEM. REFER TO

SPECIFICATION 26 24 13 FOR FURTHER INFORMATION.

5 CONNECT TO NETWORKED ELECTRIC SUBMETERING.

6 PRIMARY SERVICE, 15KV VFI SWITCHES, 15KV CONDUCTORS AND

TRANSFORMER SHALL BE PROVIDED BY CITY LIGHT AND POWER.

7 ELECTRICAL CONTRACTOR SHALL PROVIDE MANHOLES, DUCTBANK,

CONDUITS, GROUND CONDUCTORS, GROUND RODS, PULLCORDS,

CONCRETE PAD, TRENCHING AND BACKFILL.

8 CIRCUIT BREAKER TO BE LOCKED IN THE CLOSED POSITION.

PROVIDE LABEL WITH 1" HIGH LETTERING TO READ "FIRE PUMP

DISCONNECTING MEANS".

SEE DWG.

NOTE 3

SEE DWG.

NOTE 3

SEE DWG.

NOTE 2

SEE DWG.

E-602

SEE DWG.

E-602

DIST.

PNL.

S

DIST.

PNL.

N

150AT

225AF

LSIG

125AT

225AF

LSIG

N.C.

N.C.

N.O.

K

K

K

80KVA

UPS

MAINTENANCE

BYPASS PANEL

208-208Y/120V 3P,4W

10 KAIC MIN.

P A

N E

L

A P

-U L -1

-2

TER ROOM

EC-138

3#1/0 (MI CABLE)

FP

CONT.

P A

N E

L

A P

-U L -1

-1

8-[4-500KCMIL] INSTALLED IN [8 OF 8-4"C.] IN CONCRETE

ENCASED UNDERGROUND DUCTBANK E2.

OUTDOOR PAD MOUNTED

TRANSFORMER

1 2 3 4 5 6 7 8 10 11 12 13 14

LA

15KV

VFI

600A

SEE DWG. NOTE 4

30 KAIC MIN

TELECOM

EQUIPMENT

ROOM EC-138

a bc c b a

4W300AL

W

A

L

400A, 208Y/120V BUS

300AT

400AF

100AT

100AF

100AT

100AF

(3

S P

A R

E S

100AT

100AF

W

A

L

100AT

100AF

W

A

L

30AT

100AF

10 KAIC MIN.

SPD

DIST. PANEL

"DP-UL-M-1"

EMER. ELEC

ROOM EC-142B

P A

N E

L

A P

-U L -1

-3

TER ROOM

EC-138

TER ROOM

EC-138

P A

N E

L

A P

-U L -3

-1

100AT

100AF

W

A

L

P A

N E

L

A P

-U L -3

-2

100AT

100AF

W

A

L

SERVER

ROOM

EC-348B

T-DP-UL-M-1

80KVA, 3Ø, 60HZ

480-208Y/120V

Z = 5.2%

3W125AL

ARC FAULT PROTECTION

REDUCTION MAINTENANCE

SWITCH (TYP.)

(3

S P

A R

E S

ELEV.

POWER

MODULE

ELEV.

POWER

MODULE

4W60

4W30

45AT

100AF

LSIG

P A

N E

L

A P

-N L -M

-2 MAIN ELEC.

ROOM EC-142A

a bc c b a

T-AP-NL-M-2

30KVA, 3Ø, 60HZ

480 - 208Y/120V

Z = 3.8%

4W100TAL

3W45

15 17 18 20

(3

S P

A R

E S

(3

S P

A C

E S

SERVER

ROOM

EC-348B

SEE DWG.

NOTE 5

TO SUBSTATION B-PMS2

SEE DWG. NOTE 5 SEE DWG. NOTE 5

SEE DWG. NOTES 6 & 7

a bc c b a

T-AP-NL-M-1

37.5KVA, 1Ø, 60HZ

480 - 240/120V

Z = 3.8%

240KA

80KA

1200AT

1200AF

100%

SEE DWG.

NOTE 2

NEW MANHOLES

MH-5 TO MH-8 LA

15KV

XFMR T2

500KVA, 3Ø

a bc c b a

LA

15KV

VFI

600A

FUTURE 500KVA AND PRIMARY

FEEDERS FOR FUTURE WIND

TUNNEL

SEE DWG.

NOTE 2

2#2 & #8G, 1-1/2"C

SEE DWG.

NOTE 8

LSIG ARMS

65 KAIC MIN

ARMS

3000AT

3000AF

100%

LSIG

ARMS

EPO

3W125AL

4W300AL

4W300AL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

E-601

D

IA

G R

A M

S

O N

E -L

IN

E

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

D V

-E C

D V

-E C

R G

-E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

X

AP-NL-N-21 208/120V X X

DP-NL-N-2 3PH 4W

ROOM EC-232 100A, M.L.O. 18

20 1 0.2 1.40 1.2 20 1

20 1 1 2.00 1 20 1

20 2 1 2.00 1 20 1

1 2.44 1.44 20 1

20 1 1.2 2.00 0.8 20 1

20 1 1.2 1.90 0.7 20 1

20 1 1.2 1.80 0.6 20 1

20 1 1.2 2.20 1 20 1

20 2

0.5 0.70 0.2 20 1

0.5 1.82 1.32 20 1

20 2 1 2.00 1

20 2 1 2.00 1

20 1 0.8 1.60 0.8 20 1

20 1 0.4 1.00 0.6 20 1

20 1 0.6 1.20 0.6 20 1

20 1 1 1.80 0.8 20 1

20 1 1 1.60 0.6 20 1

20 1 0.6 1.20 0.6 20 1

20 1 0.8 1.70 0.9 20 1

20 1 0.00 20 1

20 1 0.00 20 1

LOAD SUMMARY PER PHASE (KVA) 12.56 10.80 9.00

TOTAL CONNECTED LOAD (KVA) 32.36

NOTE:

PANEL: VOLTAGE: NORMAL NEW

FED FROM: PHASE & WIRE: EMERGENCY EXISTING

LOCATION: MAIN (AMPS): UPS KAIC RATING:

POLES:

NOTES

CKT C.B.

DESCRIPTION

LOAD LOAD

DESCRIPTION

C.B. CKT

NOTES

NO. A P (KVA) A B C (KVA) A P NO.

1 REC - ELEC EC-232 REC - EC-232A/B, CORRIDOR 2

3 REC - CORRIDOR #6 EC-6C2 WATER COOLERS 4

SPEC REC - EC-238 & 240

3D PRINTER - WEAPONS - EC-233 6

7 PRINTER BATH - WEAPONS EC-233 8

9 MOTOR OPERATED WALL VARIABLE AIR VOLUME BOXES 10

11 MOTOR OPERATED WALL VARIABLE AIR VOLUME BOXES 12

13 MOTOR OPERATED WALL FIRE DAMPERS 14

15 MOTOR OPERATED WALL VARIABLE AIR VOLUME BOXES 16

SPEC REC - EC-231

FIRE DAMPERS 18

19 FCU-2-2 STAIR #1 EC-4S2 20

SPEC REC - EC-233 SPEC REC - EC-231

23 24

25 REC - EC-238 REC - EC-238 26

27 PROJECTOR - EC-238 REC - EC-238 28

29 REC - EC-238 REC - EC-238 30

31 REC - EC-238 REC - EC-238 32

33 PROJECTOR - EC-238 REC - EC-238 34

35 REC - EC-238 REC - EC-238 36

37 REC - ROOMS EC-244 AND EC-246 MOTORIZED SHADES - MB - 250 38

39 SPARE SPARE 40

41 SPARE SPARE 42

OPTIONS AND ACCESSORIES - (X) INDICATES SELECTION

MULTIPLE SECTION PANEL CONTACTOR CONTROLLED

RECESSED FEED THRU LUGS

SURFACE SUB FEED MAIN LUGS (DOUBLE LUGS)

200% RATED NEUTRAL CONTROLLABLE CIRCUIT BREAKER PANEL

ISOLATED GROUND BUS INTEGRAL SURGE PROTECTIVE DEVICE (SPD)

X

X

AP-NL-N-22 208/120V X X

DP-NL-N-2 3PH 4W

ROOM EC-232 100A, M.L.O. 18

20 1 0.8 1.60 0.8 20 1

20 2

0.5 1.00 0.5

20 2

0.5 1.00 0.5

20 3

1 2.00 1

20 31 2.00 1

1 2.00 1

20 1 1 2.00 1 20 1

20 3

1 2.00 1

20 31 2.00 1

1 2.00 1

20 1 1 2.00 1 20 1

20 3

1 2.00 1

20 31 2.00 1

1 2.00 1

20 1 1 2.00 1 20 1

20 1 0.4 0.80 0.4 20 1

20 1 0.4 1.40 1 20 1

20 1 1 1.00 20 1

20 1 0.00 20 1

20 1 0.00 20 1

20 1 0.00 20 1

LOAD SUMMARY PER PHASE (KVA) 10.40 10.40 10.00

TOTAL CONNECTED LOAD (KVA) 30.80

NOTE:

PANEL: VOLTAGE: NORMAL NEW

FED FROM: PHASE & WIRE: EMERGENCY EXISTING

LOCATION: MAIN (AMPS): UPS KAIC RATING:

POLES:

NOTES

CKT C.B.

DESCRIPTION

LOAD LOAD

DESCRIPTION

C.B. CKT

NOTES

NO. A P (KVA) A B C (KVA) A P NO.

1 REC - EC-236A REC - EC-236A 2

SPEC REC - EC-236A SPEC REC - EC-236A

5 6

LATHE EC-236A LATHE EC-236A

9 10

11 12

13 REC - DRILL PRESS EC-236A REC - DRILL PRESS EC-236A 14

LATHE EC-236A LATHE EC-236A

17 18

19 20

21 REC - DRILL PRESS EC-236A REC - DRILL PRESS EC-236A 22

LATHE EC-236A LATHE EC-236A

25 26

27 28

29 REC - DRILL PRESS EC-236A REC - DRILL PRESS EC-236A 30

31 REC - EC-236A REC - EC-236A 32

33 REC - EC-236A PLENUM BOX - EC-250 34

35 PROJECTOR - EC-236A SPARE 36

37 SPARE SPARE 38

39 SPARE SPARE 40

41 SPARE SPARE 42

OPTIONS AND ACCESSORIES - (X) INDICATES SELECTION

MULTIPLE SECTION PANEL CONTACTOR CONTROLLED

RECESSED FEED THRU LUGS

SURFACE SUB FEED MAIN LUGS (DOUBLE LUGS)

200% RATED NEUTRAL CONTROLLABLE CIRCUIT BREAKER PANEL

ISOLATED GROUND BUS INTEGRAL SURGE PROTECTIVE DEVICE (SPD)

X

AP-NL-N-23 208/120V X X

DP-NL-N-2 3PH 4W

ROOM EC-232 100A, M.L.O. 18

20 1 1.2 1.80 0.6 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1.2 2.40 1.2 20 1

20 2

0.5 1.00 0.5

20 2

0.5 1.00 0.5

20 1 0.6 1.20 0.6 20 1

20 1 0.6 1.20 0.6 20 1

20 1 0.6 1.20 0.6 20 1

20 1 0.4 1.00 0.6 20 1

20 1 1 1.60 0.6 20 1

20 1 0.6 1.00 0.4 20 1

20 1 0.6 1.20 0.6 20 1

20 1 1 2.00 1 20 1

20 1 1 2.00 1 20 1

20 1 1 2.20 1.2 20 1

20 2 1 2.00 1

20 2 1 2.00 1

20 1 1 2.00 1 20 1

25 1 1.65 1.65 20 1

20 1 0.00 20 1

20 1 0.00 20 1

LOAD SUMMARY PER PHASE (KVA) 11.25 9.60 10.00

TOTAL CONNECTED LOAD (KVA) 30.85

NOTE:

PANEL: VOLTAGE: NORMAL NEW

FED FROM: PHASE & WIRE: EMERGENCY EXISTING

LOCATION: MAIN (AMPS): UPS KAIC RATING:

POLES:

NOTES

CKT C.B.

DESCRIPTION

LOAD LOAD

DESCRIPTION

C.B. CKT

NOTES

NO. A P (KVA) A B C (KVA) A P NO.

1 HEAT EXCHANGER - EC-244 REC - THERMO SUPPORT EC-242 2

3 HEAT TRANSFER - EC-244 REC - THERMODYNAMICS EC-244 4

5 MOTOR OPERATED DOOR REC - THERMODYNAMICS EC-244 6

SPEC REC - THERMO EC-244 SPEC REC - THERMO EC-244

9 10

11 REC - THERMODYNAMICS EC-244 REC - THERMODYNAMICS EC-244 12

13 REC - THERMODYNAMICS EC-244 REC - THERMODYNAMICS EC-244 14

15 REC - THERMODYNAMICS EC-244 REC - THERMODYNAMICS EC-244 16

17 PROJECTOR - EC-244 REC - AERONAUTICAL EC-246 18

19 REC - AERONAUTICAL EC-246 REC - AERONAUTICAL EC-246 20

21 REC - AERONAUTICAL EC-246 PROJECTOR - AERONAUTICAL EC-246 22

23 REC - AERONAUTICAL EC-246 REC AERONAUTICAL EC-246 24

25 WIND TUNNEL - THERMO EC-244 WIND TUNNEL - THERMO EC-244 26

27 WIND TUNNEL - THERMO EC-244 WIND TUNNEL - THERMO EC-244 28

29 WIND TUNNEL AERONAUTICAL EC-246 REC - AERONAUTICAL EC-246 30

SPEC REC - EC-244 SPEC REC - EC-246

33 34

35 HELICOPTER SUPPLY AND CONTROLS FLOW VISUALIZATION TABLE 36

37 EF-2-4 - MECH ROOM EC-144 (ROOF) SPARE 38

39 SPARE SPARE 40

41 SPARE SPARE 42

OPTIONS AND ACCESSORIES - (X) INDICATES SELECTION

MULTIPLE SECTION PANEL CONTACTOR CONTROLLED

RECESSED FEED THRU LUGS

SURFACE SUB FEED MAIN LUGS (DOUBLE LUGS)

200% RATED NEUTRAL CONTROLLABLE CIRCUIT BREAKER PANEL

ISOLATED GROUND BUS INTEGRAL SURGE PROTECTIVE DEVICE (SPD)

X

AP-NL-N-25 208/120V X X

DP-NL-N-2 3PH 4W

ROOM EC-232 225A, M.L.O. 18

20 1 1.2 1.80 0.6 20 1

30 2

2.5 3.22 0.72 20 1

2.5 3.30 0.8 20 1

20 1 0.8 2.00 1.2 20 1

20 1 0.6 1.20 0.6 20 1

20 1 0.6 1.20 0.6 20 1

50 3

3 3.80 0.8 20 1

3 3.80 0.8 20 1

3 4.20 1.2 20 1

20 1 0.8 1.88 1.08 20 1

20 1 0.4 1.00 0.6 20 1

20 1 0.6 1.20 0.6 20 1

20 1 0.6 1.40 0.8 20 1

20 1 0.8 1.60 0.8 20 1

20 1 0.8 1.60 0.8 20 1

20 1 0.8 1.80 1 20 1

20 2 1 1.50 0.5

20 2 1 1.50 0.5

20 1 1.2 2.00 0.8 20 1

20 1 0.00 20 1

20 1 0.00 20 1

LOAD SUMMARY PER PHASE (KVA) 14.68 12.32 13.00

TOTAL CONNECTED LOAD (KVA) 40.00

NOTE:

PANEL: VOLTAGE: NORMAL NEW

FED FROM: PHASE & WIRE: EMERGENCY EXISTING

LOCATION: MAIN (AMPS): UPS KAIC RATING:

POLES:

NOTES

CKT C.B.

DESCRIPTION

LOAD LOAD

DESCRIPTION

C.B. CKT

NOTES

NO. A P (KVA) A B C (KVA) A P NO.

1 REC - BIO SUPPORT EC-229 ICE MAKER - EC-229 2

INSTRON TESTING - EC-229

REFRIGERATOR - EC-229 4

5 REC - BIOMECHANICS EC-231 6

7 REC - BIOMECHANICS EC-231 REC - WORKSTATION EC-231 8

9 REC - BIOMECHANICS EC-231 REC - BIOMECHANICS EC-231 10

11 REC - BIOMECHANICS EC-231 REC - BIOMECHANICS EC-231 12

TREADMILL/FORCE PLATES SPECIAL REC

BIOMECHANICS EC-231

FLOOR BOX - BIOMECHANICS EC-231 14

15 FLOOR BOX - BIOMECHANICS EC-231 16

17 REC - WORKSTATIONS EC-231 & EC-233 18

19 REC - WEAPONS EC-233 DRILL PRESS - WEAPONS EC-233 20

21 PROJECTOR - WEAPONS EC-233 REC - WEAPONS EC-233 22

23 REC - WEAPONS EC-233 REC - WEAPONS EC-233 24

25 REC - WEAPONS EC-233 REC - STUDENT COLLAB MB-251 26

27 REC - STUDENT COLLAB MB-252 REC - STUDENT COLLAB MB-253 28

29 REC - STUDENT COLLAB MB-254 REC - STUDENT COLLAB MB-255 30

31 REC - STUDENT COLLAB MB-257 PROJECTOR - BIOMECHANICS EC-231 32

TABLETOP LATHE - WEAPONS EC-233 SPEC REC - THERMO EC-233

35 36

37 TF-2-3 - ROOM EC-232 TV'S BIOMECHANICS EC-231 38

39 SPARE SPARE 40

41 SPARE SPARE 42

OPTIONS AND ACCESSORIES - (X) INDICATES SELECTION

MULTIPLE SECTION PANEL CONTACTOR CONTROLLED

RECESSED FEED THRU LUGS

SURFACE SUB FEED MAIN LUGS (DOUBLE LUGS)

200% RATED NEUTRAL CONTROLLABLE CIRCUIT BREAKER PANEL

ISOLATED GROUND BUS INTEGRAL SURGE PROTECTIVE DEVICE (SPD)

X

X

AP-NL-N-26 208/120V X X

DP-NL-N-2 3PH 4W

ROOM EC-232 225A, M.L.O. 18

20 1 1.44 2.88 1.44 20 1

20 1 1.44 2.88 1.44 20 1

20 1 1.44 2.88 1.44 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1.32 1.32

20 320 1 1.32 1.32

20 1 1.32 1.32

20 3

1.32 2.64 1.32

20 31.32 2.64 1.32

1.32 2.64 1.32

20 3

1.32 2.64 1.32

20 31.32 2.64 1.32

1.32 2.64 1.32

20 3

1.32 2.32 1 20 1

1.32 2.12 0.8 20 1

1.32 2.32 1 20 1

20 1 0.00 20 1

20 1 0.00 20 1

20 1 0.00 20 1

LOAD SUMMARY PER PHASE (KVA) 14.20 14.00 14.20

TOTAL CONNECTED LOAD (KVA) 42.40

NOTE:

PANEL: VOLTAGE: NORMAL NEW

FED FROM: PHASE & WIRE: EMERGENCY EXISTING

LOCATION: MAIN (AMPS): UPS KAIC RATING:

POLES:

NOTES

CKT C.B.

DESCRIPTION

LOAD LOAD

DESCRIPTION

C.B. CKT

NOTES

NO. A P (KVA) A B C (KVA) A P NO.

1 VERT BANDSAW - EC-236A VERT BANDSAW - EC-236A 2

3 VERT BANDSAW - EC-236A VERT BANDSAW - EC-236A 4

5 VERT BANDSAW - EC-236A VERT BANDSAW - EC-236A 6

7 SANDER/GRINDER - EC-236A SANDER/GRINDER - EC-236A 8

9 SANDER/GRINDER - EC-236A SANDER/GRINDER - EC-236A 10

11 SANDER/GRINDER - EC-236A SANDER/GRINDER - EC-236A 12

13 SPARE

MILLING MACHINE - EC-236A

15 SPARE 16

17 SPARE 18

MILLING MACHINE - EC-236A MILLING MACHINE - EC-236A

21 22

23 24

MILLING MACHINE - EC-236A MILLING MACHINE - EC-236A

27 28

29 30

MILLING MACHINE - EC-236A

REC - MANUFACTURING EC-236A 32

33 REC - MANUFACTURING EC-236A 34

35 REC - MANUFACTURING EC-236A 36

37 SPARE SPARE 38

39 SPARE SPARE 40

41 SPARE SPARE 42

OPTIONS AND ACCESSORIES - (X) INDICATES SELECTION

MULTIPLE SECTION PANEL CONTACTOR CONTROLLED

RECESSED FEED THRU LUGS

SURFACE SUB FEED MAIN LUGS (DOUBLE LUGS)

200% RATED NEUTRAL CONTROLLABLE CIRCUIT BREAKER PANEL

ISOLATED GROUND BUS INTEGRAL SURGE PROTECTIVE DEVICE (SPD)

X

AP-NL-N-24 208/120V X X

DP-NL-N-2 3PH 4W

ROOM EC-232 225A, M.L.O. 18

20 1 1.2 1.80 0.6 20 1

20 1 1.2 1.60 0.4 20 1

20 1 1 1.80 0.8 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1.2 2.20 1 20 1

20 1 1 2.20 1.2 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1.2 2.20 1 20 1

20 1 1.2 2.20 1 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1.2 2.20 1 20 1

20 1 1.2 2.20 1 20 1

20 1 1.2 2.20 1 20 1

20 1 1.2 2.40 1.2 20 1

20 1 1 2.40 1.4 20 1

20 1 1 2.00 1 20 1

20 1 0.6 1.60 1 20 1

20 1 1.2 2.40 1.2 20 1

20 1 0.7 1.60 0.9 20 1

20 1 0.00 20 1

20 1 0.00 20 1

LOAD SUMMARY PER PHASE (KVA) 14.80 12.20 13.20

TOTAL CONNECTED LOAD (KVA) 40.20

NOTE:

PANEL: VOLTAGE: NORMAL NEW

FED FROM: PHASE & WIRE: EMERGENCY EXISTING

LOCATION: MAIN (AMPS): UPS KAIC RATING:

POLES:

NOTES

CKT C.B.

DESCRIPTION

LOAD LOAD

DESCRIPTION

C.B. CKT

NOTES

NO. A P (KVA) A B C (KVA) A P NO.

1 REC - ELECTRONICS LAB EC-250 REC - ELECTRONICS LAB EC-250 2

3 REC - ELECTRONICS LAB EC-250 PROJECTOR - EC-250 4

5 REC - ELECTRONICS LAB EC-250 REC - ELECTRONICS LAB EC-250 6

7 REC - ELECTRONICS LAB EC-237 REC - ELECTRONICS LAB EC-237 8

9 REC - ELECTRONICS LAB EC-237 PLENUM BOX - EC-237 10

11 REC - ELECTRONICS LAB EC-237 REC - ELECTRONICS LAB EC-237 12

13 REC - ELECTRONICS LAB EC-239 REC - ELECTRONICS LAB EC-239 14

15 REC - ELECTRONICS LAB EC-239 PLENUM BOX - EC-239 16

17 TF-2-1 - ROOM EC-242 REC - ELECTRONICS LAB EC-239 18

19 REC - ELECTRONICS LAB EC-241 REC - ELECTRONICS LAB EC-241 20

21 REC - ELECTRONICS LAB EC-241 PLENUM BOX - EC-241 22

23 REC - ELECTRONICS LAB EC-241 REC - ELECTRONICS LAB EC-241 24

25 REC - CORRIDOR #7 EC-7C2 REC - CORRIDOR #8 EC-8C2 26

27 REC - WORKSTATIONS EC-233 REC - AERO SUPPORT EC-243 28

29 WATER COOLERS - MOE REC - MOE 30

31 VENDING MACHINE - MB-250 REC - MOE 32

33 FREESTANDING TOUCH SCREEN WATER COOLERS 34

35 TF-2-2 - ROOM EC-250 REC - TELEVISIONS EC-7C2 36

37 EF-2-5 - MECH ROOM EC-144 (ROOF) MOTORIZED SHADES - MB - 250 38

39 SPARE SPARE 40

41 SPARE SPARE 42

OPTIONS AND ACCESSORIES - (X) INDICATES SELECTION

MULTIPLE SECTION PANEL CONTACTOR CONTROLLED

RECESSED FEED THRU LUGS

SURFACE SUB FEED MAIN LUGS (DOUBLE LUGS)

200% RATED NEUTRAL CONTROLLABLE CIRCUIT BREAKER PANEL

ISOLATED GROUND BUS INTEGRAL SURGE PROTECTIVE DEVICE (SPD)

PANELBOARD SCHEDULE KEY

AP-NL-N-21

AP-NL-N-24

AP-NL-N-22

AP-NL-N-25

AP-NL-N-23

AP-NL-N-26

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

E-615

P A

N E

L B

O A

R D

S C

H E

D U

L E

S

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

D V

-E C

D V

-E C

R G

-E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

FE

J J J J J J

J

J J

J J

JJJJ

J

J J

J J J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J J

J

J

JJ

J

J

J

J J

J J J

J

J J

J

J

10 11 12 13 13.5 15

A

B

D

ELECTRONICS

LAB

EC-250

PROJECT

BASED

LEARNING

EC-238

THERMO

SUPPORT

EC-242

MECH SHAFT

PROJECT

BASED

LEARNING

EC-240

TELECOM

EC-234

ELEC

EC-232

MANUFACTURING

SUPPORT

EC-236B

AERONAUTICAL

EC-246

THERMODYNAMICS

EC-244

MANUFACTURING

EC-236A

CORRIDOR #5

EC-5C2

CORRIDOR #6

EC-6C2

CR CR CR CR CR CR

CR

CR

CR

CR

CR

CR

CR

CR

CR

CR

CR

CR

CR

CR

CR

CR CR CR

CR

CR

CR

CR

CR

CR

SEE DWG.

NOTE 1

MILLING MACHINE

(TYP. FOR 6)

CR CR CR CR CR CR

CR CR CR CR CR

CR

CR CR CRCR CR CR

MOUNT TO CLG.

SUPPORT SYSTEM

(TYPICAL)

MOUNT TO CLG.

SUPPORT SYSTEM

(TYPICAL)

CR CR PORTABLE

WIND TUNNEL

(TYP. FOR 4)

STORAGE

EC-232A

JC

EC-232B

2J-19,21,23

CR CR

CR

CR

CR

CR

FB5 FB5 FB5

FB5 FB5 FB5

FB5 FB5 FB5

EP-401

W.C.

W.C.

2D-1

2D-2

2D-2

2D-2

2D-2

2D-2

2D-3 2D-3

2D-3

2D-3

2D-3

2D-4

2D-4

2J-32

2J-32

2J-32

2J-342J-342J-34 2J-34

2J-36 2J-1

2E-31 2E-31

2E-32 2E-32

2E-33 2E-33

2E-1 2E-1 2E-1 2E-1

2E-2 2E-2 2E-2 2E-2

2E-3,5 2E-3,5

2E-4,6 2E-4,6

2D-25 2D-25 2D-25

2D-26 2D-26 2D-26

2D-27

2D-28 2D-28 2D-28

2D-29 2D-29 2D-29

2D-30 2D-30 2D-30

2D-31 2D-31 2D-31

2D-31

2D-32 2D-32 2D-32

2D-34 2D-34 2D-34

2D-35 2D-35 2D-35

2D-36 2D-36 2D-36

2D-33

2D-5,7

2E-13 2E-14 2E-21 2E-22 2E-29 2E-30

2E-7,9,11 2E-8,10,12 2E-15,17,19 2E-16,18,20 2E-23,25,27

2E-35

2E-24,26,28

2D-5,7

2D-4

2D-4

2F-2 2F-2

2F-2

2F-4 2F-4

2F-4 2F-1 2F-32F-6 2F-6 2F-6

2F-7,9 2F-7,9

2F-11 2F-12 2F-13 2F-14

2F-25 2F-26 2F-27

2F-28 2F-17

2F-18 2F-18 2F-36

2F-19 2F-19

2F-19

2F-19

2F-22

2F-30

2F-30 2F-30

2F-30 2F-30

2G-1

2G-2

2G-3

2G-1

2G-2

2G-3

2G-1

2G-2

2G-3

2G-4

2G-5

2G-6 2G-6

2G-6 2G-6

2G-6

2G-6

2J-14,16,18 2J-25,27,29

2J-20,22,24 2J-31,33,35

2J-26,28,30

2F-18

EF

2-4

2I-16,18,20

L15-50R

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

FIRE/SMOKE

DAMPER

FIRE/SMOKE

DAMPER

FIRE/SMOKE

DAMPER

2F-8,10

2F-8,10

MOTORIZED WALL

2D-9

2D-14

2D-14

2D-14

2D-14

2D-12

2D-12

2D-12

2D-12

2D-12

2D-10

2D-10

2D-10 2D-10

2D-10 2D-10 2D-10

2F-35

HELICOPTER TEST STAND

MOTORIZED

WALL

2F-5

2F-4

2F-4

2J-36

2J-36

2J-36

2E-36

2J-22J-32J-42J-52J-6

2D-2

C

B.3

14 14.7

C.5

SEE DWG.

NOTE 1

SEE DWG.

NOTE 1

SEE DWG.

NOTE 3

SEE DWG.

NOTE 1

SEE DWG.

NOTE 1

2J-7

2J-8

2J-9

2J-10

2J-11

2J-12

CR

CR

CR

2E-31

2E-32

2E-33 CRCR

2F-31,33 2F-32,342F-32,342F-31,33

CLOCK

2J-34

2J-32

CLOCK

CLOCK

CLOCK

CLOCK

CLOCK

2D-2

VAV

2D-10

TF

2-2

TF

2-1

2J-32

SEE DWG.

NOTE 2

CR CR

2F-13 2F-14

CR CR

2F-11 2F-12

CR CR

2F-13 2F-14

CR CR

2F-11 2F-12

CR CR

2F-15 2F-16

CR CR

2F-15 2F-16

CR CR

2F-15 2F-16

2F-4

SEE DWG.

NOTE 2

CR CR

2F-20 2F-21

CR CR

2F-20 2F-21

CR CR

2F-20 2F-21

CR CR

2F-23 2F-24

CR CR

2F-23 2F-24

CR CR

2F-23 2F-24

2F-19

SEE DWG.

NOTE 2

2D-25

SEE DWG.

NOTE 2

2D-25

SEE DWG.

NOTE 2

2D-31

SEE DWG.

NOTE 3

2G-36

2G-36

2G-36

SEE DWG.

NOTE 3

SEE DWG.

NOTE 3

CR

2D-37 2D-37

CR

PROVIDE (2) 1-1/4" CONDUITS WITH

PULL STRINGS TO WIND TUNNEL PAD.

2F-4 2F-19

2D-25

CLOCK

2D-31

2G-6

EF

2-5

2F-37

EPO

EPO

SEE DWG.

NOTE 4

SEE DWG.

NOTE 5

2F-37

DP-NL-N-2

2G-17

2G-35

TF

2-3

AP-NL-N-25

#37

L5-20R

100A/2P

SEE DWG

NOTE 6

2E-34

WP

30A

PP-NH-1

1. FOR GENERAL NOTES, ABBREVIATIONS, SCHEDULES, AND

SYMBOLS, REFER TO DRAWINGS E-001, E-002 & E-003.

2. COORDINATE DEVICE LOCATIONS WITH FLOOR PLANS,

CASEWORK, MILLWORK, AND FURNITURE ELEVATIONS.

REFER TO ARCHITECTURAL DETAILS AND ELEVATIONS

FOR ADDITIONAL INFORMATION. NOTIFY ARCHITECT OF

ANY DISCREPANCIES PRIOR TO ROUGH-IN.

3. REFER DETAIL 8/E-502 FOR CIRCUITING REQUIREMENTS OF AIR

VOLUME CONTROL BOXES, ASSOCIATED REHEAT COIL

CONTROL VALVES, AIR VALVES, SMOKE AND COMBINATION

FIRE/SMOKE DAMPERS.

4. REFER TO FIRE PROTECTION OR PLUMBING DRAWINGS FOR

LOCATIONS AND QUANTITIES OF MONITORED FIRE PROTECTION

SYSTEM VALVES, WATER FLOW SWITCHES AND ELECTRIC

BELLS.

6. UNLESS OTHERWISE NOTED, PROVIDE THE FOLLOWING WIRE

SIZES FOR 20A, 120V BRANCH CIRCUIT LENGTHS IN ORDER TO

LIMIT VOLTAGE DROP TO LESS THAN 3%:

A. LESS THAN 90 FEET PROVIDE 2#12 & #12G, 3/4"C.

B. MORE THAN 90 FEET BUT LESS THAN 150 FEET PROVIDE

2#10 & #10G, 3/4"C.

C. MORE THAN 150 FEET PROVIDE 2#8 & #8G, 3/4"C.

7. REFER TO DRAWINGS E-611 TO E-622 FOR PANELBOARD SCHEDULES.

8. NUMERICAL DESIGNATION BESIDE A RECEPTACLE INDICATES THE

BRANCH CIRCUIT BREAKER NUMBER AT THE PANELBOARD. REFER

TO ELECTRICAL PANEL DESIGNATION KEY FOR MORE INFORMATION.

GENERAL NOTES:

9. UNLESS OTHERWISE NOTED, ALL SPECIAL RECEPTACLES/SPECIAL

RECEPTACLE CORD REELS ARE TYPE NEMA 6-20R, 208V-1Ø.

5. DO NOT WIRE GFCI TYPE RECEPTACLES IN A THROUGH-

FEED FASHION.

10. PROVIDE LABELING AT EACH RECEPTACLE INDICATING

DESIGNATED PANEL AND CIRCUIT NUMBER.

ALL EXISTING RELOCATED EQUIPMENT SHALL BE

GOVERNMENT FURNISHED AND GOVERNMENT

INSTALLED. REFER TO ARCHITECTURAL

EQUIPMENT LIST FOR FURTHER INFORMATION.

EQUIPMENT NOTES:

1.

2. ALL ELECTRICAL DEVICES AND CONDUITS SERVING

SPECIALTY EQUIPMENT SHALL BE SURFACE

MOUNTED ON CMU WALL INSTALLATIONS.

04 8 16268

SCALE: 1/8" = 1'-0"

SECTOR FKEY PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

PLAN NORTH

EP-112F

E L E

C T

R

IC

A L P

O W

E R

P L A

N

S E

C O

N D

F L O

O R

S

E C

T O

R F

W E

S T

P O

IN

T

N

Y C

Y B

E R

E

N G

IN

E

E R

IN

G

A C

A D

E M

IC

C

E N

T E

R A

N D

P A

R K

IN

G

S T

R U

C T

U R

E F

Y

P

N

F

Y P

N

D V

-E C

D V

-E C

R G

-E C

D E

C E

M B

E R

W D

S -1

-D

-0

CONFORMED DRAWINGS – CONSTRUCTION AWARD

SCALE: 1/8" = 1'-0"1

ELECTRICAL POWER PLAN - SECOND FLOOR - SECTOR F

EP112JEP112H

E P

E

E P

E

ELECTRICAL PANEL DESIGNATION KEY

TAG PANEL NAME LOCATION SHEET #

TYPICAL DEVICE

1A-##

PANEL TAG (REFER TO

SCHEDULE BELOW)

CIRCUIT NUMBER

2D AP-NL-N-21 EC-232 EP112F

2E AP-NL-N-22 EC-232 EP112F

2F AP-NL-N-23 EC-232 EP112F

2G AP-NL-N-24 EC-232 EP112F

2I AP-NL-S-24 EC-212 EP112E

2J AP-NL-N-26 EC-232 EP112F

PROVIDE CEILING MOUNTED PLENUM BOX FSR CB-224P

PROJECTOR MOUNT WITH…