This document is a recommended spare parts list for wet scrubber and recirculation systems. The appendix specifies required spare components across multiple functional categories to ensure operational continuity and system reliability. Spray system components include nozzles, gaskets, and related items with a recommended quantity of at least 30% of installed nozzles and one complete gasket set, with specifications requiring compliance to designer-provided drawings and process diagrams. pH measurement and monitoring components include one pH sensor (critical consumable) and one pH transmitter (critical spare part).
Instrumentation spares encompass one each of level sensor, differential pressure sensor, and flow transmitter (if applicable), all designated as critical spare parts. Mechanical integration requires one flexible coupling as a critical spare part. Valve components include one repair kit per critical valve and two solenoid valves per model. Chemical dosing system spares consist of seal kits, diaphragms, and check valves (one per pump) for NaOH or other chemical dosing applications. Electrical and control components specified include complete sets of fuses (consumable), relays, and contactors (both critical spares), plus one PLC power supply and one PLC I/O module (both strategic spares). Recirculation tank spares include one level sensor spare part and one drain valve (both critical spares). Monitoring system instrumentation spares include two thermocouples and one temperature transmitter.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Annex I Recommended Spare Parts List for Wet Scrubber and Recirculation System
Category Spare Part Recommended Quantity
Remarks
Spray System Spray nozzles, gaskets, and related components
At least 30% of installed nozzles and one complete gasket set
Nozzle specifications shall comply with the drawings and process diagrams provided by the designer.
pH Measurement and Monitoring System pH Sensor 1 Critical consumable item pH Measurement and Monitoring System pH Transmitter 1 Critical spare part
Instrumentation Level Sensor 1 Critical spare part
Instrumentation Differential Pressure Sensor
1 Critical spare part
Instrumentation Flow Transmitter 1 If applicable
Mechanical Integration Flexible Coupling 1 Critical spare part
Valves Repair Kit 1 per critical valve Maintenance spare
Valves Solenoid Valves 2 per model Critical spare part
Chemical Dosing System
Basic spares: Seal Kit, diaphragm, check valves
1 per pump For NaOH or other chemical dosing pumps
Electrical and Control Fuses Complete set Consumable item
Electrical and Control Relays Complete set Critical spare part
Electrical and Control Contactors Complete set Critical spare part
Electrical and Control PLC Power Supply 1 Strategic spare part
Electrical and Control PLC I/O Module spare parts
1 Strategic spare part
Recirculation Tank Level Sensor spare parts
1 Critical spare part
Recirculation Tank Drain Valve 1 Critical spare part
Monitoring System Thermocouples 2 Instrumentation spare
Monitoring System Temperature Transmitters
1 Instrumentation spare