This document is a Qualification Requirements table specifying personnel requirements for a fall protection systems project. The table details minimum qualifications for key positions including Program Manager/Project Manager, Designer of Record, Reviewing Engineer, Site Safety and Health Officer, Quality Control Manager, Fall Protection System Maintenance & Repair Mechanic, and On-site Coordinator/Site Superintendent.

Detailed requirements include specific experience levels, educational backgrounds, and certifications for each role. For example, the Program Manager must have 10 years of design-build construction management experience, a BS degree, and either a professional certification (such as Certified Construction Manager or Project Management Professional) or 20 years of construction management experience. Similarly, other positions have specific requirements around professional engineering licenses, safety certifications, experience with Beam & Trolley and Horizontal Lifeline systems, and specialized training like OSHA construction safety courses.

View the file

Other files for this federal contract opportunity

Other files attached to Roof Fall Protection Systems Services, newest first.
File Type Posted
GOVT RESPONSE TO OFFEROR QUESTIONS.pdf PDF
Solicitation Amendment HQ003426RE0040001 SF 30.pdf PDF
HQ003426RE004 Sign-In Sheet.pdf PDF
J26 Contract NDA Form.pdf PDF
J-14 Pentagon Labeling Std Rev 9.pdf PDF
J-15 2021 Excavation Permit Application Form fillable.pdf PDF
J-19 Project Man Hours Work DART Rate Example.pdf PDF
J-9 PFGS Spec Sections_(01-32).pdf PDF
J-11 Pentagon_Reservation_Exterior_Standards_Manual.pdf PDF
J-10 Pentagon Historic Concrete Specifications.pdf PDF
J-4 ADAP Form 219-704 Subcontracting Plan Format.docx DOCX document
J-17 Asbestos Location OM Program.pdf PDF
J-5 Past Performance Data Sheet.docx DOCX document
J-2 WD Constr. VA20250013 02-28-2025.pdf PDF
J-1 PWS.pdf PDF
J-24 Reservation Area Designation Plan.pdf PDF
J-21 EDS Project Kickoff Presentation.pdf PDF
J-22 FSD Electronic Data Standards_6.1.pdf PDF
J-23 ComplianceChecklist_24_XXX_Name_Submission_Date.xlsx XLSX spreadsheet
J-18 Project Man Hours Work DART Rate.xlsx XLSX spreadsheet
J-13 Sample_DID.pdf PDF
J-3 WD Services 2015-4281 Rev 34 07.08.2025.pdf PDF
J-20 AEC_CAD Standards 6.1.pdf PDF
J25 Contractor-Conflict-of-Interest-Disclosure-Form.pdf PDF
J-8 WHS Fire Regulations 2022 Edition.pdf PDF
J-12 Reservation_Finish_Standards.pdf PDF
J-7 WHS_Building_Code_2022.pdf PDF
J-6 Contractor Past Performance Questionnaire PPQ.docx DOCX document
Solicitation - HQ003426RE004.pdf PDF
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The Contractor must submit resumes of all key personnel to the Government that documents the following Qualification Requirements:

Position Minimum Qualification Requirements

Program Manager / Project Manager - Experience with both Beam and Trolley (B&T) and Horizontal Lifeline (HLL) fall protection systems

- 10 years design-build construction management experience, BS degree in construction management or engineering related field, and at least one of the following certifications or registrations:

- Active Certified Construction Manager (CCM) certified by the Construction Manager Certification Institute.

OR

- Active Project Management Professional (PMP) certification issued by the Project Management Institute

OR

- Active Certified Professional Constructor (CPC) certified by the American Institute of Constructors & Constructor Certification Commission

OR

- Active Designated Design-Build Professional certification administered by the DBIA

OR

-Active Licensed Professional Registration in Virginia, Maryland, District of Columbia, or Pennsylvania.

If no Certification or License, then Project Manager must have 20 years of Construction Management experience.

Designer of Record

- Professional Enginner (PE) licensed in Virginia, Maryland, District of Columbia, or Pennsylvania

- 5 years of experience designing and certifying fall protection systems

Designer of Record - BS degree in an engineering or architectural discipline.

- 10 years of design experience.

- Active Licensed Professional Registration in Virginia, Maryland, District of Columbia, or Pennsylvania.

Reviewing Engineer

Site Safety and Health Officer

(SSHO)

- 5 years of continuous construction industry safety experience in supervising/managing general construction or three years if they possess a Certified Safety Professional (CSP) or safety and health degree.

- Must have completed the 30-hour OSHA Construction Safety Class or, as an equivalent, 30 hours of formal construction safety and health training covering the subjects of the OSHA 30-hour course (see EM385-1-1, Appendix A, paragraph 3.d.3) applicable to the work to be performed and given by qualified instructors.

Quality Control Manager - Refer to PFGS

Fall protection System Maintenance & Repair Mechanic

- Shall be qualified to work on fall protection system equipment in accordance with manufacturers' requirements for both Beam & Trolley (B&T) and Horizontal Lifeline (HLL) systems.

On-site Coordinator/ Site Superintendent

-5 years of experience working on both Beam & Trolley (B&T) and Horizontal Lifeline (HLL) systems.

-10 years of experience as Construction Site Superintendent -Completion of OSHA training