02_82_00_Fencing.pdf

PDF 9 KB Posted

Attached to
Environmental Remediation Services at the former Belle Mead Army Depot in Belle Mead, NJ
Solicitation number
GS-03-P-17-AZ-C-0001
Issued by

About this file

Fencing

View the file

Other files

File Type Posted
GS-03-P-17-AZ-C-0001_Amendment_004.pdf PDF
BMAD_North_Parcel_RFI_Responses_Amendment_004.pdf PDF
2016-11-15_Belle_Mead_Rev._3_(1).pdf PDF
Solicitation_GS-03-P-17-AZ-C-0001_Amendment_003.pdf PDF
Schedule_A-20161102.xlsx XLSX spreadsheet
31_22_00_Backfill_and_Grading-Rev20161103.pdf PDF
31_05_19_Geosynthetics_for_Earthworks-Rev20161103.pdf PDF
32_92_00_Turf_and_Grasses-Rev20161103.pdf PDF
02_11_60_Demolition-Rev20161103.pdf PDF
Sitework.Planting.Gravel.Crushed.jpg JPG image
20161103-Bid_Addendum_summary.docx DOCX document
Sitework.Planting.Grass.Short.jpg JPG image
Exist_Conds.txt TXT text file
31_23_16_Excavation-rev20161102.pdf PDF
Sitework.Planting.Gravel.Mixed.jpg JPG image
DWG_To_PDF.pc3 —
Concrete.Cast-In-Place.Flat.Grey.1.jpg JPG image
Sitework.Planting.Grass.Thick.jpg JPG image
Solicitation_GS-03-P-17-AZ-C-0001_Amendment_002.pdf PDF
32_90_00_Planting-Rev20161103.pdf PDF
2016-11-03_Belle_Mead_Rev._3.pdf PDF
01_30_00_ePMS-rev20161103.pdf PDF
RFI_Responses_Amendment_0002.pdf PDF
01_57_19_Temporary_Environmental_Control-Rev21061103.pdf PDF
_ACM-G-STANDARD.ctb —
01_22_00_Unit_Prices-Rev20161103.pdf PDF
Exist_Conds.dwg DWG drawing
02_51_00_Decontamination-rev20161103.pdf PDF
Sitework.Planting.Soil.jpg JPG image
PreProposal_Sign_In.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Appendix_A.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Appendix_D.pdf PDF
Pre-proposal_Agenda_BMAD_North_Parcel_Remediation_-_Construction.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Appendix_C.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Exhibit_A_-_Permit_Application.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Appendix_B.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Exhibit_A_-_Permit_Application_contd_III.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Exhibit_A_-_Permit_Application_contd_II.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Appendix_E.pdf PDF
Solicitation_GS-03-P-17-AZ-C-0001_Amendment_001.pdf PDF
2016_BelleMead_GP4-10_FHA_WQC_Exhibit_A_-_Permit_Application_contd.pdf PDF
RAWP-NorthParcel-BMAD_20160811_FO.pdf PDF
Solicitation_GS-03-P-17-AZ-C-0001_SF1442.pdf PDF
C301.pdf PDF
C101-SB_BMAD_NP_Remediation.pdf PDF
20161017_TreeMitigation_NorthParcel.pdf PDF
C201-SB.pdf PDF
Schedule_A-20161019.xlsx XLSX spreadsheet
2016-10-19_Belle_Mead_Rev._2.pdf PDF
SESCP-Application.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GSA Belle Mead Army Depot Belle Mead, New Jersey PCN #

January 2016 FENCING 028200 - 1

SECTION 028200 - FENCING

PART 1 - GENERAL

1.01 DESCRIPTION:

A. Furnish all labor, materials, tools and equipment for the installation of chain link fencing as shown in the Drawings.

1.04 REFERENCES:

A. American Society for Testing and Materials (ASTM):

ASTM A 392 Revision A, Standard Specification for Zinc-Coated Steel Chain Link Fence Fabric

1. ASTM C 33, Standard Specification for Concrete Aggregates

2. ASTM C 150, Standard Specification for Portland Cement

3. ASTM F 567, Standard Practice for Installation of Chain-Link Fence

4. ASTM F 626, Standard Specifications for Fence Fittings

5. ASTM F 1043 Standard Specification for Strength and Protective Coatings on

Steel Industrial Fence Framework

1.02 SUBMITTALS:

A. Prior to installation Contractor shall provide manufacturer specifications, cut sheets, drawings, details, installation instructions, and maintenance recommendations for chain link fencing.

B. Following installation, Contractor shall provide written certification that Contractor has installed the fencing system in accordance with manufacturer’s recommendations and that the fencing system has been inspected by Contractor and found free and clear of any defects.

C. Contractor shall submit the initial and continuously updated New Jersey One Call report numbers as soon as they are obtained, along with the subsequent reports after they are completed.

1.03 PROJECT CONDITIONS:

A. The approximate locations and dimensions of structures to be removed are indicated in the Contract Documents. The Contractor may encounter foundations, utilities, wooden or other pilings, surface slabs, and other debris during fence installation. If the Contractor encounters a structure not shown in the Contract Documents, the Contractor shall notify the Engineer immediately.

B. Surface and subsurface structure work shall be performed in a manner that does not disturb or damage existing utilities, structures, or other items found within the work area. Contractor is responsible for repairing and/or replacing damaged items at no cost to Owner.

1.04 COORDINATION AND SCHEDULING

GSA Belle Mead Army Depot Belle Mead, New Jersey PCN #

January 2016 FENCING 028200 - 2

A. Work shall be coordinated maintenance of temporary security fencing such that temporary security fencing shall remain in place until installation and final acceptance of permanent fencing, unless otherwise directed by the Engineer

PART 2 - PRODUCTS

2.01 FENCE HEIGHT:

A. Fence height shall be as indicated in the Drawings or as otherwise directed by the Engineer.

B. Product details for fencing and fencing appurtenances may change based on fence height.

Contractor shall provide materials and installation of fencing system based upon manufacturer’s recommendations for the appropriate fence height.

2.02 FENCE TYPE:

A. Chain link fence type shall be zinc coated steel woven fabric conforming to ASTM A 392 REV A.

2.03 FENCING SYSTEM:

A. A complete fencing system shall include all posts, braces, wires, concrete, rails, connections, and other appurtenances as recommended by the manufacturer.

2.04 CONCRETE FOR POST FOOTINGS:

A. Concrete shall consist of Type I Portland cement complying with ASTM C 150, aggregates complying with ASTM C 33, and clean water. Concrete mix shall be proportioned such that the 28-day compressive strength of moist-cured laboratory samples achieves not less than 3,000 pounds per square inch (psi).

PART 3 - EXECUTION

3.01 INSTALLATION:

A. Contractor shall inspect the work area prior to beginning work and identify to Engineer, in writing, any and all site conditions that may interfere with the work to be completed by Contractor.

B. Contractor shall locate and protect nearby utilities, structures, fences, vegetation, and other items shown in the Contract Drawings.

C. Contractor shall install a complete fencing system as determined through manufacturer recommendations, the Drawings, and the Engineer.

D. Subcontractor shall not install fence fabric until concrete has cured for a minimum of two days.

END OF SECTION