Abingdon_100__Submission_Drawings_130524.pdf
PDF 17 MB Posted
- Attached to
- Multiple Award, Indefinite Delivery/Indefinite Quantity (IDIQ) for WV & VA Federal contract opportunity
- Solicitation number
- GS-03P-13-CD-D-0018
About this file
Abingdon Courtroom Drawings
View the file
Other files for this federal contract opportunity
Show all 35
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900 Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
M101-01 FIRST FLOOR HVAC NEW WORK PLAN
M102-02 SECOND FLOOR HVAC NEW WORK PLAN
G-001 COVER M103-03 ROOF HVAC NEW WORK PLAN
G-002 SYMBOLS, NOTES AND ABBREVIATIONS M401-02 SECOND FLOOR ENLARGED HVAC PLAN
G-003 CODE ANALYSIS M501 MECHANICAL DETAILS
M801 MECHANICAL CONTROLS
M802 MECHANICAL CONTROLS
AD101-01 FIRST FLOOR DEMOLITION PLAN
AD102-02 SECOND FLOOR DEMOLITION PLAN
AD103-01 FIRST FLOOR DEMOLITION RCP PD101-01 FIRST FLOOR PLUMBING DEMOLITION PLAN AD104-02 SECOND FLOOR DEMOLITION RCP PD102-02 SECOND FLOOR PLUMBING DEMOLITION PLAN
A-101-01 FIRST FLOOR NEW WORK PLAN P-101-01 FIRST FLOOR PLUMBING NEW WORK PLAN
A-102-02 SECOND FLOOR NEW WORK PLAN P-102-02 SECOND FLOOR PLUMBING NEW WORK PLAN
A-103-01 FIRST FLOOR NEW WORK RCP P-401-02 ENLARGED PLUMBING PLANS
A-104-01 SECOND FLOOR NEW WORK RCP P-601 PLUMBING SCHEDULES, DETAILS AND RISERS
A-401-01 ENLARGED PLANS AND SECTION
A-402-01 ENLARGED PLANS AND ELEVS
A-403-02 ENLARGED PLANS AND SECTIONS
A-404-02 ELEVATIONS AND SECTION E-001 LEGENDS, SYMBOLS AND GENERAL NOTES
A-501-02 GRAND JURY DETAILS ED101-01 LIGHTING DEMOLITION PLAN, 1ST FLOOR
A-502-02 GRAND JURY DETAILS ED102-02 LIGHTING DEMOLITION PLAN, 2ND FLOOR
A-503 MILLWORK DETAILS ED103-01 POWER DEMOLITION PLAN, 1ST FLOOR
A-504 CEILING DETAILS ED104-02 POWER DEMOLITION PLAN, 2ND FLOOR
A-505 DETENTION DETAILS EL101-01 LIGHTING NEW WORK PLAN, 1ST FLOOR
A-506 DOOR AND FRAME DETAILS EL102-02 LIGHTING NEW WORK PLAN, 2ND FLOOR
A-507 DOOR AND FRAME DETAILS EP101-01 POWER NEW WORK PLAN, 1ST FLOOR
A-601 DOOR SCHEDULE EP102-02 POWER NEW WORK PLAN, 2ND FLOOR
A-602 FINISH SCHEDULE AND PATTERN PLANS EP103-03 POWER NEW WORK PLAN, PENTHOUSE
A-701 PARTITION TYPES E-601 ELECTRICAL RISER DIAGRAM
E-602 LIGHTING FIXTURE SCHEDULES
HAZMAT E-603 ELECTRICAL PANELBOARD SCHEDULES
HA-101 FIRST FLOOR ASBESTOS ABATEMENT PLAN FIRE ALARM
HA-102 SECOND FLOOR ASBESTOS ABATEMENT PLAN FJ101-01 FIRE ALARM/ SECURITY DEMOLITION PLAN, 1ST FLOOR
FJ102-02 FIRE ALARM/ SECURITY DEMOLITION PLAN, 2ND FLOOR
STRUCTURAL F-101-01 FIRE ALARM/ SECURITY NEW WORK PLAN, 1ST FLOOR
F-102-02 FIRE ALARM/ SECURITY NEW WORK PLAN, 2ND FLOOR
S-001 STRUCTURAL GENERAL NOTES F-103-B1 FIRE ALARM/ SECURITY NEW WORK PLAN, BASEMENT
S-501 STRUCTURAL DETAILS
TELECOMMUNICATIONS
MECHANICAL
TJ101-01 TELECOMMUNICATIONS/ AV DEMOLITION PLAN, 1ST FLOOR
M-001 MECHANICAL LEGEND AND GENERAL NOTES TJ102-02 TELECOMMUNICATIONS/ AV DEMOLITION PLAN, 2ND FLOOR M-002 MECHANICAL SCHEDULES T-101-01 TELECOMMUNICATIONS/ AV NEW WORK PLAN, 1ST FLOOR MD101-01 FIRST FLOOR HVAC DEMOLITION PLAN T-102-02 TELECOMMUNICATIONS/ AV NEW WORK PLAN, 2ND FLOOR
MD102-02 SECOND FLOOR HVAC DEMOLITION PLAN
GENERAL
ARCHITECTURE
PLUMBING
ELECTRICAL
Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
Height Width Door
Thickness Material Finish Type Material Finish Type Jamb Head
R100 7'-0" 3'-0" 1-3/4"
HM PNT 1 WD WD A 20 X HW-07 1/A506
1/A506
SIM
Match existing wood doors on Level 1 (Oak Veneer w/ Natural Stain), Provide infrastructure for intercom to Judges Chambers and keypad or card reader.
R118
HM PNT 1 WD WD A
X HW-07 1/A506
1/A506
SIM
Remove door, clean, prep, re-finish, and re-install. Reuse of door
118. Refer to F101 for FA requirements.
R119 _ _ _ HM PNT 1 WD WD A _ X HW-07 1/A506
1/A506
SIM
Remove door, clean, prep, re-finish, and re-install. Reuse of door
122. Refer to F101 for FA requirements.
R121 7'-0" 3'-0" 1-3/4"
HM PNT 1 HM PNT A 20 HW-06 X 1/A506
1/A506
SIM
R122 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A HW-04 1/A506
1/A506
SIM
R123 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A HW-02 1/A506
1/A506
SIM
R124 7'-0" 2'-0" (Pair) 1-3/4" - - - WD PNT B HW-09 Cased opening with bi-fold door hardware.
R125 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A HW-02 1/A506
1/A506
SIM
R126 7'-0" 3'-0" 1-3/4"
HM PNT 1 HM PNT A HW-06 X 1/A506
1/A506
SIM
R127 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A 20 HW-06 X 2/A506
2/A506
SIM
R128 7'-0" 3'-0" 1-3/4"
HM PNT 1 HM PNT A 20 HW-03 1/A506
1/A506
SIM
R129 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A 20 HW-01 1/A506
1/A506
SIM
131 _ _ _ HM PNT _ WD WD _ _ _ _ _ _ Existing door to remain, paint frame as scheduled.
R131B 7'-0" 3'-0" _ HM PNT 2 _ _ _ _ _ 4/A506
4/A506
SIM
Cased opening in existing partiton - provide frame anchor as suitable for existing partition
133 _ _ _ HM PNT _ WD WD _ _ _ _ _ _ Existing door to remain, paint frame as scheduled.
133A _ _ _ HM PNT _ WD WD _ _ _ _ _ _ Existing door to remain, paint frame as scheduled.
135 _ _ _ HM PNT _ WD WD _ _ _ _ _ _ Existing door to remain, paint frame as scheduled.
R136 7'-0" 3'-0" 1-3/4" HM PNT 1 WD WD A 20 X HW-07 1/A506
1/A506
SIM
Door hardware will include cipher lock, existing partiton - provide frame anchor as suitable for existing partition
152 _ _ _ HM PNT _ HM HM _ _ X _ _ _ _
Existing door to remain, prep for infrastructure for strobe light and toggle switch indicating in-custody defendant movement.
R160 7'-0" 3'-0" 2" DHM PNT D1 DHM PNT DB 20 X SH-220 19/A506 18/A506 Add Rockwood #624 x US26 vision scope to door.
R161 7'-0" 3'-0" 2" DHM PNT D1 DHM PNT DA SH-220 X 2/A507 1/A507
R162 7'-0" 3'-0" 2" DWM SS DWM SS SH-210 _ _ Security mesh cell front and door, refer to 7/A505 R163 7'-0" 3'-0" 2" DWM SS DWM SS SH-210 _ _ Security mesh cell front and door, refer to 7/A505 R164 7'-0" 3'-0" 2" DWM SS DWM SS SH-210 _ _ Security mesh cell front and door, refer to 6/A505 R165 3'-0" 2'-0" 2-3/16" PLT PNT PLT PNT 20 SH-110 _ _ DE, Refer to 8/A505 R166 3'-0" 2'-0" 2-3/16" PLT PNT PLT PNT 20 SH-110 _ _ DE, Refer to 8/A505 R167 7'-0" 3'-0" 2" DHM PNT D1 DHM PNT DB 90 SH-220 X 19/A506 18/A506 Add Rockwood #624 x US26 vision scope to door.
R168 3'-0" 2'-0" 2-3/16" PLT PNT PLT PNT 20 SH-110 _ _ Refer to 8/A505 R169 2'-6" 4'-6" 2-3/16" PLT PNT PLT PNT SH-210 _ _ Field Verify Opening Size, Refer to 8/A505
R221 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT 20 X HW-05 1/A506
1/A506
SIM
Existing partition, provide frame anchor as suitable for existing partition
R223 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT 20 HW-05 1/A506
1/A506
SIM
Existing partition, provide frame anchor as suitable for existing partition
R225 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT 20 HW-05 1/A506
1/A506
SIM
Existing partition, provide frame anchor as suitable for existing partition
R227 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT 20 HW-05 1/A506
1/A506
SIM
Existing partition, provide frame anchor as suitable for existing partition
R231 _ _ _ HM PNT _ HM PNT _ _ _ _ _ _ Remove door, clean, prep, paint, and re-install.
R234 _ _ _ HM PNT _ HM PNT _ _ _ _ _ _ Remove door, clean, prep, paint, and re-install.
R234A 4'-0" 4'-0" _ 3 _ _ _ _ X _ _ _ _ Transaction drawer located in PLAM countertop, refer to 6/A503.
R237 _ _ _ HM PNT _ HM PNT _ _ _ _ _ _
Remove door, clean, prep, paint, and re-install. Existing door is louver.
R238 _ _ _
HM PNT _ HM PNT _ _ _ _ _ _
Remove door, clean, prep, paint, and re-install. Existing door is louver.
R239 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A 20 X HW-09 1/A506
1/A506
SIM
Keypad and remote release controlled by transaction window position in room R234. Refer to F102 for FA requirements.
R240 7'-0"
3'-0" 1-3/4" HM PNT 1 HM PNT A 20 X HW-07 1/A506
1/A506 SIM Relocate existing device.
R241 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A 20 X HW-07 1/A506
1/A506
SIM
Keypad and remote release controlled by transaction window position in room R234.
R242 7'-0"
3'-0" 1-3/4" HM PNT 1 HM PNT A 20 HW-06 X 1/A506
1/A506
SIM
R243 7'-0" 3'-0" 1-3/4" HM PNT 1 WD WD1 A 20 HW-06 X 3/A506
3/A506
SIM
Wood trim applied over HM frame inside room R243, gives appearance of wood frame.
R244 7'-0" 3'-0" 1-3/4" HM PNT 1 WD WD1 A 20 HW-06 X 1/A506
1/A506
SIM
R245 7'-0" 3'-0" 1-3/4" HM PNT 1 WD WD1 A 20 HW-06 X 3/A506
3/A506
SIM
Wood trim applied over HM frame inside room R243, gives appearance of wood frame.
R246 7'-0" 3'-0" 1-3/4" HM PNT 1 HM PNT A 90 X HW-08 1/A506
1/A506
SIM
Prep for infrastructure for strobe light indicating in-custody defendant movement.
R246A 7'-0"
3'-8" 1/3/2004 HM PNT 2 _ _ _ 90 _ 5/A506
5/A506 SIM Cased Opening
R247 7'-0" 3'-0" 1-3/4" HM PNT 1 WD WD1 A 90 X HW-07 X 6/A507
6/A507
SIM
Wood trim applied over HM frame inside room R243, gives appearance of wood frame.
R248 7'-0" 3'-0" 2" DWM SS DWM SS _ SH-210 _ _ Security mesh cell front and door, refer to 6/A505
R249 7'-0" 3'-0" 1-3/4" HM PNT 1 WD WD1 A _ HW-01 X 3/A506
3/A506
SIM
Wood trim applied over HM frame inside room R243, gives appearance of wood frame.
R250 7'-0" 3'-0" 1-3/4" HM PNT 1 WD WD1 A _ HW-02 X 3/A506
3/A506
SIM
Wood trim applied over HM frame inside room R243, gives appearance of wood frame.
R251 7'-0" 2'-6" 1-3/4" HM PNT 1 WD WD1 A _ HW-05 3/A506
3/A506
SIM
Wood trim applied over HM frame inside room R243, gives appearance of wood frame.
R252 7'-0" 2'-6" 1-3/4" HM PNT 1 WD WD1 A _ HW-05 3/A506
3/A506
SIM
Wood trim applied over HM frame inside room R243, gives appearance of wood frame.
R254 7'-0" 3'-0" 2" DHM PNT D1 DHM PNT DB 90 SH-220 5/A507
5/A507
SIM Add Rockwood #624 x US26 vision scope to door.
R255 7'-0" 3'-0" 2" DHM PNT D1 DHM PNT DA SH-220 X 4/A507 3/A507 Add sound gasketing, ADB and threshold for STC40 rating.
R256 4'-0" 3'-0" 2-3/16" PLT PNT _ PLT PNT SH-210 _ _ Refer to 5/A505 R257 4'-0" 3'-0" 2-3/16" PLT PNT _ PLT PNT SH-210 _ _ Refer to 5/A505
Door Acoustical
Door Remarks
Opening Schedule
Level 2
Details
Level 1
Opening Size
UL
Label
Security Device
(By Owner) Hardware
Set
Frame
Number
CPT1 Manufacturer: Masland Contract CPT5 Manufacturer: Karastan PNT1 Manufacturer: Benjamin Moore RB1 Manufacturer: Johnsonite APC1 Manufacturer: Armstrong Style: TopLine Style: Pointillism Color: HC-93 Carrington Beige Style: Millwork Base, Reveal 8" Style: Ultima, 2' x 2' Color: 7445 Distinctive Color: 13939 Nickel Finish: Egg Shell Color: TBD Color: White
Other: Broadloom Other: Broadloom Other:
Beveled Tegular Edge with 9/16" Suprafine XL Suspension System
PNT2 Manufacturer: Benjamin Moore WB1 Species: Cherry CPT2 Manufacturer: Lees TZ1 Manufacturer: Terroxy Color: HC-93 Carrington Beige Finish: Clear Satin Lacquer APC2 Manufacturer: Armstrong
Style: The Field II GT104 Color: TM #13-242, Refer to specification Finish: Semi Gloss Color: Custom Stain, Match Architect's Sample Style:
Ultima Techzone, Sizes vary refer to plan
Color: 354 Beach Tan Other: 3/8" Epoxy Terrazzo Flooring Color: White
Other: Carpet Tile, Monolithic PNT4 Manufacturer: Trussbilt Other:
Beveled Tegular Edge with 9/16" Suprafine XL Suspension System
VCT1 Manufacturer: Armstrong Color: Match cream base of GMU1 CT3 Manufacturer: Dal-Tile
CPT3 Manufacturer: Lees Style:
Imperial Texture Standard Excelon, 12" X 12" Finish: Factory Finished Metal Wall Panel Style: Rittenhouse Square, 3" x 6" Cove Base
Style: The Groove II GT103 Color: 51803 Pearl White Color: Almond Color: 354 Beach Tan CT2 Manufacturer: Dal-Tile Pattern: Running Bond Other: Carpet Tile, Quarter Turn VCT2 Manufacturer: Armstrong Style: Rittenhouse Square, 3" x 6" Field Tile
Style:
Imperial Texture Standard Excelon, 12" X 12" Color: Almond CT4 Manufacturer: Dal-Tile PNT3 Manufacturer: Benjamin Moore
CPT4 Manufacturer: Karastan Color: 57502 Café Latte Pattern: Running Bond Style: Rittenhouse Square, 3" x 6" Bull Nose Color: White Style: Plateau II Color: Almond Finish: Egg Shell Color: 659 French Mint CT1 Manufacturer: Dal-Tile AFWP1 Manufacturer: Maharam Pattern: Running Bond Other: Broadloom Style: Keystones 3" x 3" Fabric: Sharkskin 2 901650 SMC1 Manufacturer: Trussbilt, Barrier Dek
Color: Marble Color: 034 Suggestion Color: White Other: 24" Plank Metal Ceiling
GMU1 Manufacturer: SpectraGlaze Color: Custom Clear II Style: Astra Glaze II w/ integral cove base
Floor Walls Base, Molding, and Chair Rail Ceilings
Basis of Design, Field Verify and Match Existing Carpet and Pad
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900 Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
Room # Room Walls Floors Base Ceiling Remarks
FIRST FLOOR
R100 Corridor PNT1 CPT3 RB1 PNT3 on Existing
GWB
R101 Corridor Existing Existing Existing PNT3 on Existing
GWB, APC1
R118 Corridor PNT1 CPT3 RB1 APC1
R119 Corridor Existing CPT3 RB1 PNT3 on Existing
GWB
R121 Soundlock PNT1 CPT1 RB1 APC1
R122 Video/ Equipment Storage PNT1 VCT2 RB1 APC1 Refer to 1/A602 for pattern plan R123 Jury Toilet PNT2/CT2 CT1 CT3 PNT3 on GWB Refer to 1/A602 for pattern plan R124 Closet PNT1 CPT1 RB1 PNT3 on GWB R125 Jury Toilet PNT2/CT2 CT1 CT3 PNT3 on GWB Refer to 1/A602 for pattern plan
R126 Trial Jury Room PNT1 CPT1 RB1 APC1, PNT3 on GWB Furniture is NIC
R128 Staff Toilet PNT2/CT2 CT1 CT3 PNT3 on GWB Refer to 1/A602 for pattern plan
R129 Breakroom PNT2 VCT1 and 2 RB1 APC1 Furniture and Refrigerator are NIC, Refer to 1/A602 for pattern plan
R131 Magistrate Chambers Expansion PNT (match adjacent room 129)
CPT4 (match adjacent room 129)
RB (match adjacent room 129)
PNT (Match adjacent room 129) New radiator cover to match cover in 129.
R133 Office PNT (match adjacent room 129) CPT4 (match adjacent room 129)
RB (match adjacent room 129)
PNT (Match adjacent room 129) New radiator cover to match cover in 129.
R135 Conference Room PNT (match adjacent room 129) CPT4 (match adjacent room 129)
RB (match adjacent room 129)
PNT (Match adjacent room 129) New radiator cover to match cover in 129.
R136 CSO Break Room PNT1 CPT5 RB1 ACP1 Radiator, existing to remain - paint to match walls.
R136A Toilet Existing Existing Existing PNT3 on GWB R136B Toilet Existing Existing Existing PNT3 on GWB 141 Law Library Existing Existing Existing Existing 145 Law Clerk Existing Existing Existing Existing 142B Judges Toilet Existing Existing Existing PNT3 on GWB 146 Office Existing Existing Existing PNT3 on GWB 150 Files Existing Existing Existing PNT3 on GWB R160 Secure Corridor GMU1/ PNT1 CPT3 GMU1/ RB1 APC1 R161 Sallyport GMU1 TZ1 GMU1 SMC1 R162 Holding GMU1 TZ1 GMU1 SMC1 R163 Holding GMU1 TZ1 GMU1 SMC1 R164 HC Holding GMU1 TZ1 GMU1 SMC1 R167 Sallyport GMU1/ PNT1 CPT3 GMU1/ RB1 ACP1
SECOND
FLOOR
R221 Director's Office
PNT1 CPT5 RB1
APC1, PNT3 on Existing GWB Radiator, existing to remain - paint to match walls.
R221A Toilet PNT1/ Existing Tile Existing Existing
APC1, PNT3 on Existing GWB Radiator, existing to remain - paint to match walls.
R221B Closet
PNT1 CPT5 RB1
APC1, PNT3 on Existing GWB Radiator, existing to remain - paint to match walls.
R223 Reception/ Conference
PNT1 CPT5 RB1
APC1, PNT3 on Existing GWB Radiator, existing to remain - paint to match walls.
R225 Deputy Office
PNT1 CPT5 RB1
APC1, PNT3 on Existing GWB Radiator, existing to remain - paint to match walls.
R227 Deputy Office
PNT1 CPT5 RB1
APC1, PNT3 on Existing GWB Radiator, existing to remain - paint to match walls.
R229 USMS Storage
PNT1 CPT5 RB1
APC1, PNT3 on Existing GWB Radiator, existing to remain - paint to match walls.
R231 Federal Public Defender Office PNT1 Existing RB1
APC1, PNT3 on Existing GWB New radiator cover to match cover in 129.
R234 US Attorney Office
PNT1 CPT2 RB1
APC1, PNT3 on
GWB
R236 Corridor PNT1 CPT3 RB1 APC1
R237 US Attorney Office
PNT1 CPT2 RB1
APC1, PNT3 on
GWB
R238 US Attorney Office
PNT1 CPT2 RB1
APC1, PNT3 on
GWB
R239 Corridor PNT1 CPT3 RB1 APC1
R240 Reception/ Waiting PNT1 CPT3 RB1
APC1, PNT3 on GWB Furniture NIC.
R242 Witness Room PNT1 CPT2 RB1
APC1, PNT3 on
GWB
BENCH WALL - WD1, PNT1
SIDE WALLS - PNT1
BACK WALL - AFWP1 above Chair Rail, PNT1
R244 Witness Room PNT1 CPT2 RB1
APC1, PNT3 on
GWB
R247 Sound Lock PNT4 CPT3 PNT4 APC1 R248 USMS Holding Cell PNT4 TZ1 PNT4 SMC1 R249 Service Unit PNT2 VCT1 and 2 RB1 APC1 Refer to 2/A602 for pattern plan R250 Toilet PNT2/CT2 CT1 CT3 APC1 Refer to 2/A602 for pattern plan R251 Closet PNT1 CPT1 RB1 APC1 R252 Closet PNT1 CPT1 RB1 APC1
R254 Stair B Match Existing Paint Match Existing Painted Sealed Concrete
Match Existing Cove Base
GWB, Match Existing Paint
R255 Sallyport PNT4 TZ1 PNT4 SMC1
R243
Grand Jury Hearing Room CPT1 WB1 APC2, PNT3 on
GWB
Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
V
T
S
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
MARK CFM
FRAME
SIZE
IN
NECK
SIZE
IN
REMARKS
GRILLE AND DIFFUSER SCHEDULE
NOTES:
1. MAXIMUM 30 NC.
2. MAXIMUM 0.1" STATIC PRESSURE.
3. ALL DIFFUSERS/GRILLES/REGISTERS TO BE CONSTRUCTED OF STEEL UNLESS NOTED OTHERWISE.
4. 2-SLOT, 3/4" SLOT WIDTH, 9/16" TEE, TO BE COMPATIBLE WITH INSTALLED CEILING SYSTEM. FURNISH
A 12" HIGH BY 60" LONG SUPPLY PLENUM FOR ALL SUPPLY LINEAR SLOT DIFFUSERS.
5. 4-SLOT, 3/4" SLOT WIDTH, 9/16" TEE, TO BE COMPATIBLE WITH INSTALLED CEILING SYSTEM. FURNISH
A 12" HIGH BY 30" LONG SUPPLY PLENUM FOR ALL SUPPLY LINEAR SLOT DIFFUSERS.
6. PROVIDE REMOTE CABLE OPERATED DAMPER ACCESSED THROUGH FACE OF AIR DEVICE. (TITUS
AGR-35-AAS OR EQUIVALENT)
0-110 6"Ø
115-240 8"Ø
245-320 10"Ø
325-500 12"Ø 24"x24"
505-700 14"Ø
LOUVER FACE SUPPLY DIFFUSER1
1 24"x24" PERFORATED FACE RETURN / TRANSFER GRILLE
0-100 6"x6" FIXED FACE EXHAUST GRILLE8"x8"
0-300 8"Ø2 60"x6" LINEAR SLOT DIFFUSER (NOTE 4)
0-400 12"x12"
405-950 22"x22"
705-900 16"Ø
3 0-300 30"x6" OPEN TO
PLENUM
LINEAR SLOT RETURN GRILLE (NOTE 4)
FILTER SECTION
TYPE(KW)
CAPACITY
(°F) E.A.T.
HEATING
NOTES:
AIR HANDLING UNIT SCHEDULE
-12
87654321
OCTAVE BAND
MAX SOUND POWER LEVELS (DB REF 10 WATTS)COOLING COIL
DROP (IN. WG)
AIR PRESSURE
MAX INITIAL
(MBH)
SENSIBLE
(MBH)
TOTALWBDBWBDB
CAPACITYL.A.T. (°F)E.A.T. (°F)
RPM
HP
MOTOR
MIN
(IN. WG)
FLOW
S.P. AT MAX
EXTERNAL
CFM
O.A.
MIN
CFM
MIN
CFM
MAX
SUPPLY FAN SECTION
TYPEMARK
DROP (IN. WG)
MAX AIR
PRESSURE
MARK DRIVE DESCRIPTION CFM
MIN
MOTOR
HP
RPM
-12
TYPE
EXT
STATIC
AT MAX
FLOW
(IN. WG)
MIN BLADE
OR WHEEL
DIAMETER
(IN.)
MAX SOUND POWER LEVELS (DB REF 10 WATTS)
OCTAVE BAND
1 2 3 4 5 6 7 8
1.
FAN SCHEDULE
NOTES:
SOUND POWER LEVELS SHALL BE MEASURED AT FAN DISCHARGE.
EF-1 CENTRIFUGAL PRV DIRECT TRIAL JURY SUITE EXHAUST 200 0.5 11 1/20 1550 72 74 69 62 60 58 50 47
RTU-1 HEAT PUMP 1400 1400 670 0.6 0.75 1656 82.1 67.3 54.0 53.0 56.1 43.3 0.3 33.3 16.7 TA-V 14 0.3 76 74 74 68 62 60 54 48
RTU-2 HEAT PUMP 2360 1800 1800 0.7 2.0 1856 82.3 68.0 54.0 53.0 108.3 73.5 0.3 43.1 20.0 0.3
MARK CAPACITY
(LB/HR)
NOTES:
DEHUMIDIFICATION UNIT SCHEDULE
WBDB
E.A.T. (°F)
75.0 63.0
DB
L.A.T. (°F)
75.05DU-1 200
BASIS OF DESIGN
MUNTERS DRY COOL HD0.4
V/PH
120/1
CFM
SUPPLY AIRSTREAM
ESP
REACTIVATION AIRSTREAM
CFM ESP
200 0.4
1. EXTERNAL STATIC PRESSURE DROP DOES NOT INCLUDE INLET VANES, COOLING COIL, HEATING
COIL, FILTER, MIXING BOX, OR CASING LOSSES.
2. COIL FACE VELOCITY SHALL NOT EXCEED 500 FPM.
3. PROVIDE INTEGRAL STARTER WITH RTU-1. PROVIDE VFD WITH RTU-2.
MERV
4. FILTER TYPES SHALL BE AS FOLLOWS: TYPE TA-V SHALL BE 4-INCH THROWAWAY FILTERS IN A "V" ARRANGEMENT. UNIT SELECTION SHALL INCLUDE AN ADDITIONAL FILTER LOADING ALLOWANCE OF 0.25"
FOR TYPE TA-V.
5. PROVIDE VIBRATION ISOLATION OF FANS INTERNAL TO RTU.
6. HEATING CAPACITY SHALL BE MET BY THE HEAT PUMP DOWN TO 17°F AMBIENT TEMPERATURE. PROVIDE
ELECTRIC HEAT AT SCHEDULED CAPACITY FOR OPERATION BELOW 17°F.
0-300 12"x6"4 12"x6" ADJUSTABLE BAR SUPPLY REGISTER
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900 Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
1. PROVIDE 12x12 GRAVITY RELIEF VENT GV-1 FOR ASSOCIATED EXHAUST.
ELECTRICAL SERVICE
VOLTS/PHASE MCA
208/3 35.5
208/3 60.1TA-V 14
GPM(MBH)
CAPACITY
HOT WATER COIL
TYPEMARK
TERMINAL UNIT SCHEDULE
VAV-1(E) VAV 1050 315 8.9 0.9
HOT WATER COIL CAPACITIES SHALL BE BASED ON 55°F
E.A.T. AND 180°F E.W.T WITH A 20°F TEMPERATURE DROP.
WATER PRESSURE DROP SHALL NOT EXCEED 5 FT WG.
TERMINAL UNIT TYPES ARE AS FOLLOWS: TYPE VAV
SHALL BE VARIABLE VOLUME WITH HOT WATER COIL.
1.
2.
VALVE
MAX
CFM
VALVE
MIN
CFM
NOTES:
2. PROVIDE HANGER SPRINGS FOR VIBRATION ISOLATION.
76 74 74 68 62 60 54 48
7. RTU-2 SHALL INCLUDE A FLAT PLATE HEAT EXCHANGER.
8. RTU-2 SHALL BE A 100% OUTDOOR AIR UNIT.
RPM
HP
MOTOR
MIN
(IN. WG)
FLOW
S.P. AT MAX
EXTERNAL
CFM
MAX
EXHAUST FAN SECTION
2435 2.0 2 1887
EF-2 CENTRIFUGAL PRV DIRECT TOILET ROOM EXHAUST 150 0.5 11 1/4 1725 69 67 68 57 53 46 42 38
EF-3 LIGHT DUTY PRESSURE BLOWER DIRECT SECOND FLOOR HOLDING CELL 440 1.8 - 1 3500 - - - - - - - -
ELECTRICAL SERVICE
VOLTS/PHASE
120/1
120/1
120/1
MAXIMUM SECURITY, SUICIDE DETERRENT
SUPPLY REGISTER (NOTE 6)
TU-1 VAV 800 270 8.9 0.9
TU-2 VAV 1560 1560 54.2 5.4
0-155 8x8
160-400 12x12
10x10
14x14
2 0-300 14"x14" 12"x12"
MAXIMUM SECURITY, SUICIDE DETERRENT
TRANSFER GRILLE (NOTE 6)
BASIS OF DESIGN
VALENT VPR-110-5J-20E-A-1DX
VALENT VPRP-110-10J-20E-A-1CX
BASIS OF DESIGN
GREENHECK G-080-D
GREENHECK G-097-A
GREENHECK FPB-90H-M10
MARK SIZE
(WxHxL)
NOTES:
HEPA FILTER SCHEDULE
24x12x12HEPA-1 440
BASIS OF DESIGN
CAMFIL FARR MODEL 12XH-23F11F12
RESISTANCE
0.3 1.5
1. PROVIDE SIDE ACCESS FILTER HOUSING.
AIRFLOW
(CFM) INITIAL
(IN WG)
FINAL
(IN WG)
24x12x12HEPA-2 868 0.5 1.5
24x12x12HEPA-3 868 0.5 1.5
2. INSTALL HEPA-2 AND HEPA-3 SIDE BY SIDE IN ONE FILTER HOUSING.
CAMFIL FARR MODEL 12XH-23F11F12
CAMFIL FARR MODEL 12XH-23F11F12
MAXIMUM SECURITY, SUICIDE DETERRENT
EXHAUST GRILLE (NOTE 6)
0-300 12"x12"
305-860 18"x18"
14"x14"
20"x20"
800-850 18"x18" FIXED FACE EXHAUST GRILLE20"x20"
D1
D2
D3
D4
D4 D4D4
D6
D5
D5
D5
D5
T
D7
D8
D9
D10
D11
D12
D13
D13D12
D14
D15
D16
D17
D5
D5
D5
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
D4
D3
D2
D5
D6D6
D6
D6
D6
D6
D6
D6
D6
D6
D6
D8
D8
T
D10
T
T
T
T
D12
T
D10
D10
D10
D10
D7D6
D10
T
D13
T
T
T
D9
D14
D15
D15
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
1 1
1 T H
2 6
TT
3 3
19 20
P
T P
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
1 1
T
T
T
T
T
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900 Arlington, Va, 200 703-682-4900 tel 703-682-4901 fax www.aecom.com
DUCTWORK
L3x3x1/4 x4" LONG
PL 1/4x6x6H
EI
G H
T
TO
S U
IT
E
Q P
T
FU
R N
IS
H
ED L5x3x1/4 LLH
LENGTH TO SUIT
DUCT SIZE
PIPE 2" STD
1/2" CONC AHR
T
H
T
3 1
P
P
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
TACK WELD BOLT TO
DUCT FLANGE (TYP)
WALL
#9 (1.13"Ø) STEEL BARS.
WELD MAN BARS TO
2" DUCT FLANGE
NOTES:
LARGER THAN 96 SQUARE INCHES.
PROVIDE FOR ALL WALL PENETRATIONS
WELD BARS TOGETHER TO FORM GRID.
PROTECTED SIDE
DUCT PENETRATING
WALL
2"x3"x3/16"
STEEL ANGLE. FABRICATE
TO FIT DUCT OPENING
12"x12" ACCESS DOOR
ON BOTTOM OF DUCT
3" NEOPRENE
IMPREGNATED CANVAS
NOTES:
LARGER THAN 96 SQUARE INCHES.
PROVIDE FOR ALL WALL PENETRATIONS
2" FLANGE (TYP)
FLEX CONNECTION
ON ALL FOUR SIDES
2"x3"x3/16" STEEL ANGLE
FABRICATED TO FIT OPENING.
GRID OPENINGS SHALL NOT EXCEED 30 SQ. IN.
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
TS-1
AI
SD-1
DI (W)
TS-3
AI (W)
AFMS-1
AI
D-2
AO
D-1
AO
DPS-1
DI
HS-2
AI
TS-2
AI
AFMS-2
AI
TS-4
AI
TS-5
AI
TS-6
AI
HS-1
AI
TS-1
AI
H HS-1
AI
TS-1
AI
D-3
AO
AIR-TO-AIR HX
RAW OA
FROM
OUTSIDE
D-1
BO
DPS-1
AI
FI
LT
ER
DPS-2
AI
FI
LT
ER
MERV 8 MERV 14
PS-D3
AI
FAN
SF-SS
BO
SF-S
BI
VFD-1
SA-SPD
AO
SUPPLY
TS-2
AI
HS-2
AI
HS-1
AI
DPS-3
AI
FI
LT
ER
HEPA
AI AI
D-2
BO
FAN
EA-SS
BO
EA-S
BI
VFD-2
EF-SPD
AO
EXHAUST
EXHAUST
TO
OUTSIDE
N.O.
N.C.
N.C.
N.C.
SPS-2
AI
ES1-D1
BI
ES2-D1
BI
ES1-D2
BI
ES2-D2
BI
AFMS-1
AI
SD-1
DI
TS-5
AI
TS-6
AI
TS-7
AI
EXHAUST
FROM
CELLBLOCK
TS-4
AI
TS-3
AI
HS-3
AI
SPS-1
AI
H-O-A
DO
ALARM
DI
H W
S H
W R
N.O.
V-1
AO
D-1
H HS-1
AI
TS-1
AI
TS-8
AI
HS-4
AI SD-1
DI
EXHAUST
FROM
JURY ROOM
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
CR
DI
S/S
DO
CR
DI
S/S
DO
DPS
AI
DPS
AO
ALARM
DO
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
D2
D3
D2
D4
D4
D5
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
1 4
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
2"
SANITARY SEWER
P-TRAP
CONNECTION ABOVE
WATER SEAL
FLOOR FLOOR DRAIN
DOMESTIC COLD WATER
1/2" LINE OFF TOP OF SUPPLY PIPING
TRAP PRIMER
MOUNTED IN VERTICAL
IN ACCESSIBLE LOCATION
DISTRIBUTION LINE,
COPPER, FULL SIZE OF
DISTRIBUTION UNIT OUTLET
1/8" PER
WALL OR CHASE
TO ADDITIONAL FLOOR
DRAINS AS REQUIRED
FOOT SLOPE
MINIMUM
DISTRIBUTION UNIT (NOT
REQUIRED FOR TRAP
PRIMER VALVE SERVING
ONLY ONE FLOOR DRAIN)
HOT COLD
WC-1 WATER CLOSET 3" 1 1/2" - 1/2" FLOOR MOUNTED, TANK-TYPE, 1.6 GPF
WC-2 WC/LAV COMBINATION UNIT 4" 2" 1/2" 1/2" FLOOR MOUNTED, SS, SECURITY
WC-3 WC/LAV COMBINATION UNIT 4" 2" 1/2" 1/2" FLOOR MOUNTED, SS, SECURITY, ADA
L-1 LAVATORY 1 1/2" 1 1/2" 1/2" 1/2" WALL-HUNG, ADA, 0.5 GPM AERATOR
S-1 PANTRY SINK 1 1/2" 1 1/2" 1/2" 1/2" COUNTER MOUNTED, STAINLESS STEEL, ADA, DISPOSER
FD FLOOR DRAIN 3" - - - SELF PRIMING
OSD OPEN SITE DRAIN 3" - - -
REMARKS
PLUMBING FIXTURE SCHEDULE
ITEM
DESIGNATION DESCRIPTION WASTE VENT
WATER
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
TAG
Parallel
Sets
Phase Qty.
Phase Conductor
Neutral Qty.
Neutral Conductor
Ground Qty.
Ground Conductor
Isolated Ground
Qty.
Isolated Ground
Conductor Conduit
1 1 3 #6 AWG 1 #6 AWG 1 #10 AWG 0 -- 1" EMT
2 1 3 #4 AWG 1 #4 AWG 1 #8 AWG 0 -- 1-1/2" EMT
3 1 3 #4 AWG 0 -- 1 #8 AWG 0 -- 1-1/2" EMT
4 1 3 #1 AWG 1 #1 AWG 1 #6 AWG 1 #6 AWG 2" EMT
5 1 3 #1/0 AWG 1 #1/0 AWG 1 #6 AWG 0 -- 2" EMT
6 1 3 #3/0 AWG 0 -- 1 #6 AWG 0 -- 2" EMT
Feeder Schedule
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
MDP (EXISTING)
PANEL: MAIN BUS RATING 600A
MAIN BREAKER: 3 FRAME 600A TRIP 600A TYPE MCB
VOLTAGE: 208 Y120, 3P, 4 WIRE MINIMUM INTERRUPTING CAPACITY (RMS SYM AMPS) 18,000
CONNECTED LOAD (KVA) CKT BRKR CKT BRKR CONNECTED LOAD (KVA)
A B C * TRIP P NO NO P TRIP * A B C
13.60 ------ ------ 1 2 ------ ------ ------ 13.60 ------ 3 4 ------ ------ ------ ------ 13.60 5 6 ------ ------
------ ------ 1 7 8 ------ ------ ------ ------ 1 9 10 ------ ------ ------ ------ 1 11 12 ------ ------
------ ------ 1 13 14 ------ ------ ------ ------ 1 15 16 ------ ------ ------ ------ 1 17 18 ------ ------
3.87 ------ ------ 1 19 20 2.19 ------ ------ ------ 5.91 ------ 1 21 22 ------ 2.08 ------ ------ ------ 4.08 1 23 24 ------ ------ 3.58
------ ------ 2 25 26 ------ ------ ------ ------ 27 28 ------ ------ ------ ------ 2 29 30 ------ ------
------ ------ 31 32 ------ ------ ------ ------ 2 33 34 ------ ------ ------ ------ 35 36 ------ ------
------ ------ 1 37 38 ------ ------ ------ ------ 1 39 40 ------ ------ ------ ------ 1 41 42 ------ ------
LEFT SUB-TOTAL 17.47 19.50 17.68
RIGHT SUB-TOTAL 2.19 2.08 3.58 CONNECTED DEMAND
PER PHASE T OTAL 19.66 21.58 21.26 KVA 62.3 46
PANEL TOTAL 62.50 AMPS 173.0 128
* NOTES: (N = NEW, E = EXST TO REMAIN UNO, G = GF, L = LOCKABLE, S = SHUNT T RIP)
T OTAL PANEL LOAD
CIRCUIT
DESCRIPT ION
PANEL A
POWER BSMT . A/C
LIGHT FIRST FLOOR
PANEL Cp
IT C
SPACE
PANEL C
MDP
NO. OF POLES:
ISOLAT ED GROUND XFMR
N 150
CIRCUIT
DESCRIPT ION
RTU-1 & RTU-2
LIGHT ING FIRST FLOOR
EXISTING (NOT LABELED)
PANEL E
LIGHT ING SECOND FLOOR
PANEL LB
E 100
E 100
E 100
E 125
E 125
E 100
3 100
3 100
3 225
N 100
3 100
PANEL E (EXISTING)
PANEL: MAIN BUS RATING 225A
MAIN BREAKER: 3 FRAME 225A TRIP TYPE MLO
VOLTAGE: 208 Y120, 3P, 4 WIRE MINIMUM INTERRUPTING CAPACITY (RMS SYM AMPS)
CONNECTED LOAD (KVA) CKT BRKR CKT BRKR CONNECTED LOAD (KVA)
A B C * TRIP P NO NO P TRIP * A B C
LIGHTS: RM 129 ------ ------ E 20 1 1 2 1 20 E ------ ------ RECPT: RM 121
LIGHTS: RM 123/127 ------ ------ E 20 1 3 4 1 20 E ------ ------ RECPT: RM 127
LIGHTS: RM 121 ------ ------ E 20 1 5 6 1 20 E ------ ------
LIGHTS: PITETE JURY RM ------ ------ E 20 1 7 8 1 20 E ------ ------ RECPT: RM 123/127/129
RECPT ------ ------ E 20 1 9 10 1 20 E ------ ------ RECPT: RM 121
RECPT ------ ------ E 20 1 11 12 1 20 E ------ ------ RECPT: 123
RECPT ------ ------ E 20 1 13 14 1 20 E ------ ------ RECPT: 129/131
RECPT ------ ------ E 20 1 15 16 1 20 E ------ ------ RECPT
OPEN ------ ------ E 20 1 17 18 1 20 E ------ ------ RECPT
RM R131: RECEPT 0.54 ------ ------ N 20 1 19 20 1 20 N ------ ------ SPARE
RM R131/R133/R135: RECEPT ------ 1.26 ------ N 20 1 21 22 1 20 N ------ 0.82 ------ RM R126: DU-1 JURY SUITE: RECEPT ------ ------ 1.08 N 20 1 23 24 1 20 N,IG ------ ------ 1.50 RM R131: COPIER RM R126: RECPT 0.61 ------ ------ N 20 1 25 26 1 20 N, IG 0.72 ------ ------ RM R133/R135: IG RECEPT RM R129: REFRIGERATOR ------ 0.75 ------ N 20 1 27 28 1 20 N, IG ------ 1.08 ------ RM R126: IG RECEPT RM R129: SMALL APPLIANCE ------ ------ 1.00 N 20 1 29 30 1 20 N ------ ------ SPARE RM R129: SMALL APPLIANCE 1.00 ------ ------ N 20 1 31 32 1 20 N ------ ------ SPARE RM R129: SMALL APPLIANCE ------ 1.00 ------ N 20 1 33 34 1 20 N ------ ------ SPARE
RM R126: UCR ------ ------ 0.50 N 20 1 35 36 1 20 N ------ ------ SPARE
RM R126:SMALL APPLIANCE 1.00 ------ ------ N 20 1 37 38 1 20 N ------ ------ SPARE RM R126:SMALL APPLIANCE ------ 1.00 ------ N 20 1 39 40 1 20 N ------ ------ SPARE
SPARE ------ ------ N 20 1 41 42 1 20 N ------ ------ SPARE
LEFT SUB-TOTAL 3.15 4.01 2.58
RIGHT SUB-TOTAL 0.72 1.90 1.50 CONNECTED DEMAND
PER PHASE TOTAL 3.87 5.91 4.08 KVA 13.9 14
PANEL TOTAL 13.86 AMPS 38.5 38
* NOTES: (N = NEW, E = EXST TO REMAIN UNO, G = GF, L = LOCKABLE, S = SHUNT TRIP, IG = ISOLATED GROUND)
1. PROVIDE NEW ISOLATED GROUND BAR. PROVIDE NEW #6AWG ISOLATED GROUND WIRE BACK TO SERVICE PANEL GROUND.
DESCRIPTION
CIRCUIT
TOTAL PANEL LOAD
CIRCUIT
DESCRIPTION
E
NO. OF POLES:
PANEL Bp (EXISTING)
PANEL: MAIN BUS RATING 225A
MAIN BREAKER: 3 FRAME 100A TRIP TYPE MLO
VOLTAGE: 208 Y120, 3P, 4 WIRE MINIMUM INTERRUPTING CAPACITY (RMS SYM AMPS)
CONNECTED LOAD (KVA) CKT BRKR CKT BRKR CONNECTED LOAD (KVA)
A B C * TRIP P NO NO P TRIP * A B C
ROOF: EF-1 0.25 ------ ------ N 15 1 1 2 E ------ ------ SPACE
ROOF: EF-2 ------ 0.51 ------ N 15 1 3 4 E ------ ------ SPACE
------ ------ 0.48 5 6 E ------ ------ SPACE
0.48 ------ ------ 7 8 E ------ ------ SPACE
------ 0.48 ------ 9 10 E ------ ------ SPACE
ROOF: RECEPTS. ------ ------ 0.36 N 20 1 11 12 E ------ ------ SPACE
SPACE ------ ------ E 13 14 E ------ ------ SPACE
SPACE ------ ------ E 15 16 E ------ ------ SPACE
SPACE ------ ------ E 17 18 E ------ ------ SPACE
LEFT SUB-TOTAL 0.73 0.98 0.84
RIGHT SUB-TOTAL CONNECTED DEMAND
PER PHASE TOTAL 0.73 0.98 0.84 KVA 2.6 3
PANEL TOTAL 2.55 AMPS 7.1 7
* NOTES: (E = EXST TO REMAIN UNO, G = GF, L = LOCKABLE, S = SHUNT TRIP, IG = ISOLATED GROUND, N=NEW)
N 315
DESCRIPTION
NO. OF POLES:
Bp
CIRCUIT
ROOF: EF-3
TOTAL PANEL LOAD
CIRCUIT
DESCRIPTION
MDP -2 (EXISTING)
PANEL: MAIN BUS RATING 800A
MAIN BREAKER: 3 FRAME 600A TRIP 500A TYPE MCB
VOLTAGE: 208 Y120, 3P, 3 WIRE MINIMUM INTERRUPTING CAPACITY (RMS SYM AMPS)
CONNECTED LOAD (KVA) CKT BRKR CKT BRKR CONNECTED LOAD (KVA)
A B C * TRIP P NO NO P TRIP * A B C
------ ------ 1 2 16.67 ------ ------ ------ ------ 3 4 ------ 16.67 ------ ------ ------ 5 6 ------ ------ 16.67
------ ------ 1 7 8 ------ ------ ------ ------ 1 9 10 ------ ------ ------ ------ 1 11 12 ------ ------
------ ------ 1 13 14 ------ ------ ------ ------ 1 15 16 ------ ------ ------ ------ 1 17 18 ------ ------
------ ------ 1 19 20 ------ ------ ------ ------ 1 21 22 ------ ------ ------ ------ 1 23 24 ------ ------
------ ------ 2 25 26 ------ ------ ------ ------ 27 28 ------ ------ ------ ------ 2 29 30 ------ ------
------ ------ 31 32 ------ ------ ------ ------ 2 33 34 ------ ------ ------ ------ 35 36 ------ ------
LEFT SUB-TOTAL
RIGHT SUB-TOTAL 16.67 16.67 16.67 CONNECTED DEMAND
PER PHASE TOTAL 16.67 16.67 16.67 KVA 50.0 63
PANEL TOTAL 50.00 AMPS 138.8 173
* NOTES: (E = EXST TO REMAIN UNO, G = GF, L = LOCKABLE, S = SHUNT TRIP)
3 100
3 40
20 20
50AHU-5
CIRCULATION PUMP #2
CIRCULATION PUMP #1
E
E
1. PLEASE NOTE THAT THESE LOADS ARE NOT MEASURED PEAK DEMAND LOADS. THESE
LOADS WERE CALCULATED BASED ON CONSTRUCTION DOCUMENTS FROM PAST
RENOVATION PROJECTS.
E
E
E
REFRIGERATION MACHINE
AHU-6
N
3 225
DESCRIPTION
EXISTING EQPM. (NOT LABELED)
CIRCUIT
DESCRIPTION
200 3 150
CIRCUIT
E
E
MDP-2 (High Voltage)
NO. OF POLES:
E
E
E
TOTAL PANEL LOAD
COND. WATER PUMP #1
COND. WATER PUMP #2
RTU-1 & RTU-2 (ELEC. HEAT)
REFRIGERATION MACHINE
COOLING TOWER FAN
ELEVATOR
E
PANEL Cp
PANEL: MAIN BUS RATING 100A
MAIN BREAKER: 3 FRAME 100A TRIP 100 TYPE MCB
VOLTAGE: 208 Y120, 3P, 4 WIRE MINIMUM INTERRUPTING CAPACITY (RMS SYM AMPS) 10K
CONNECTED LOAD (KVA) CKT BRKR CKT BRKR CONNECTED LOAD (KVA)
A B C * TRIP P NO NO P TRIP * A B C
RM R231: IG RECEPT 0.36 ------ ------ N, IG 20 1 1 2 1 20 N 0.18 ------ ------ SALLYPORT R255: RECEPT.
RM R243: IG RECEPT ------ 1.08 ------ N, IG 20 1 3 4 1 20 N ------ ------ SPARE
RM R243: IG RECEPT ------ ------ 1.08 N, IG 20 1 5 6 1 20 N ------ ------ SPARE
RM R234/R237: IG RECEPT 0.90 ------ ------ N, IG 20 1 7 8 1 20 N ------ ------ SPARE
RM R249: COFFEE MAKER ------ ------ N 20 1 9 10 1 20 N ------ ------ SPARE
RM R249: REFRIGERATOR ------ ------ 1.00 N 20 1 11 12 1 20 N ------ ------ SPARE
RM R249: MICROWAVE 0.75 ------ ------ N 20 1 13 14 1 20 N ------ ------ SPARE
RM R236: COPIER ------ 1.00 ------ N, IG 20 1 15 16 1 20 N ------ ------ SPARE
SPARE ------ ------ 1.50 N 20 1 17 18 1 20 N ------ ------ SPARE
SPARE ------ ------ N 20 1 19 20 1 20 N ------ ------ SPARE
SPARE ------ ------ N 20 1 21 22 1 20 N ------ ------ SPARE
SPARE ------ ------ N 20 1 23 24 1 20 N ------ ------ SPARE
SPARE ------ ------ N 20 1 25 26 1 20 N ------ ------ SPARE
SPARE ------ ------ N 20 1 27 28 1 20 N ------ ------ SPARE
SPARE ------ ------ N 20 1 29 30 1 20 N ------ ------ SPARE
LEFT SUB-TOTAL 2.01 2.08 3.58
RIGHT SUB-TOTAL 0.18 CONNECT ED DEMAND
PER PHASE TOTAL 2.19 2.08 3.58 KVA 7.7 8
PANEL TOTAL 7.85 AMPS 21.3 21
* NOTES: (N = NEW, E = EXST TO REMAIN UNO, G = GF, L = LOCKABLE, S = SHUNT TRIP, IG = ISOLATED GROUND)
1. PROVIDE ISOLATED GROUND BAR. PROVIDE #6 AWG ISOLATED GROUND WIRE BACK T O SERVICE PANEL GROUND.
DESCRIPT ION
CIRCUIT
TOTAL PANEL LOAD
CIRCUIT
DESCRIPT ION
Cp
NO. OF POLES:
AECOM TECHNICAL SERVICES, INC.
3101 Wilson Blvd. Suite 900
| G-001 |
| G-002 |
| G-003 |
| AD101-01 |
| AD102-02 |
| AD103-01 |
| AD104-02 |
| A-101-01 |
| A-102-02 |
| A-103-01 |
| A-104-02 |
| A-401-01 |
| A-402-01 |
| A-403-02 |
| A-404-02 |
| A-501-02 |
| A-502-02 |
| A-503 |
| A-504 |
| A-505 |
| A-506 |
| A-507 |
| A-601 |
| A-602 |
| A-701 |
| HA-101 |
| HA-102 |
| S-001 |
| S-501 |
| M-001 |
| M-002 |
| MD101-01 |
| MD102-02 |
| M-101-01 |
| M-102-02 |
| M-103-03 |
| M-401 |
| M-501 |
| M-801 |
| M-802 |
| PD101-01 |
| PD102-02 |
| P-101-01 |
| P-102-02 |
| P-401 |
| P-601 |
| E-001 |
| ED101-01 |
| ED102-02 |
| ED103-01 |
| ED104-02 |
| EL101-01 |
| EL102-02 |
| EP101-01 |
| EP102-02 |
| EP103-03 |
| E-601 |
| E-602 |
| E-603 |
| FJ101-01 |
| FJ102-02 |
| F-101-01 |
| F-102-02 |
| F-103-B1 |
| TJ101-01 |
| TJ102-02 |
| T-101-01 |
| T-102-02 |
File details come from the government source that posted it. Updated .