G14642XD-2 REV00.pdf
PDF 685 KB Posted
- Attached to
- REVISED Flow Sensor Test Article (F-STAr) pump
- Solicitation number
- 4-B176-Q-00517-00
- Issued by
-
Department of Energy Office of Science
About this file
This document appears to be a technical drawing for a Flow Sensor Test Article (F-STAr) pump that is the subject of a federal contract opportunity solicitation. The drawing provides detailed specifications for the pump, including maximum depth, opening, and fluid level limits.
The related federal contract opportunity is a solicitation from the Department of Energy Office of Science for the design, fabrication, and testing of the F-STAr pump, which will be installed in Argonne National Laboratory's Mechanisms Engineering Test Loop. The work includes providing all required documentation, certifications, and delivering the fabricated pump to Argonne National Laboratory. The solicitation specifies that the award will be based on lowest price, technically acceptable proposals. Interested offerors are requested to submit a signed RFQ form, pre-award information, and evidence of technical capability.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum and Acknowledgment Doc F-STAr.doc | DOC document | |
| Addendum and Acknowledgement Doc.doc | DOC document | |
| Enclosure 1 Instructions to Offerors_G4-135011.doc | DOC document | |
| Enclosure 3 FSTAR Pump Supplier Evaluation Criteria rv6.pdf | ||
| G14642XD-2 REV01.pdf | ||
| G14642XD-1 REV01.pdf | ||
| Enclosure 2 ANL-70 Request for Quotation.doc | DOC document | |
| Enclosure 4 Specifications and Statement of Work.pdf | ||
| Addendum and Acknowledgement Doc 2.doc | DOC document | |
| Appendix A-71COM-13-FEB-2023.PDF | ||
| Enclosure 1 Instructions to Offerors_G4-135011.doc | DOC document | |
| Addendum and Acknowledgement Doc.doc | DOC document | |
| Enclosure 2 ANL-70 Request for Quotation.doc | DOC document | |
| Enclosure 3 Evaluation Criteria.pdf | ||
| Enclosure 4 Specification Document.pdf | ||
| ANL-70 Request for Quotation.doc | DOC document | |
| Reps Certs ANL-70B (Blank).doc | DOC document | |
| G14642XD-1 REV00.pdf | ||
| Specification Document.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION A-A
DEPTH LIMITS
SECTION B-B
CIRCUMFERENTIAL ENVELOPE
WITHIN DEPTH LIMITS
*Limitations apply, consult with technical representative
A A
B B
A A
B B
C C
D D
DATE
PROJECT NO:PROJECT:
DESCRIPTION:
F-STAr
F-STAr Flange-Vessel Assembly
PART NUMBER:
G14642XD-2
REV
DATE
DATE
DO NOT SCALE DRAWING
SHEETSCALE
APVD/RELEASED
PROJECT MGR
GP LEADER
4/25/2024
DATE
DATE
SHEET SIZE
` .02
` .1
` .005
ALL DIMENSIONS ARE INCHES
RESPONSIBLE ENGINEER
CHECKED
` 1/2~ ` 1/64
ANGULAR TOL
.XXX
.XX
.X
J. Rein
REMOVE ALL BURRS AND SHARP EDGES
SURFACES TO BE IN ACCORDANCE
DRAWN BY
J. Rein
MATERIAL
DIMENSIONS & TOLERANCES IN
ACCORDANCE WITH LATEST ASME Y14.5M
WITH LATEST ANSI B46.1
UNLESS OTHERWISE NOTED
DECIMAL TOLERANCE
DATE
FRACTIONAL TOL
Argonne
NATIONAL LABORATORY
C
1 : 4
INV ENT OR 201 3 AJ B RE V O CT 2 014
RELEASED
STATUS:
ITEM NO. NEXT ASSEMBLY QTY. REQ'D.
4/25/2024 n9.50
MAXIMUM OPENING
25.25
MINIMUM DEPTH
75.00
MAXIMUM DEPTH
MAXIMUM FLUID LEVEL
n10.25 n14.625
2.188
VESSEL OPENING LIMITS
PUMP OPENING
PUMP OPENING