G14642XD-2 REV01.pdf
PDF 540 KB Posted
- Attached to
- REVISED Flow Sensor Test Article (F-STAr) pump
- Solicitation number
- 4-B176-Q-00517-00
- Issued by
-
Department of Energy Office of Science
About this file
This document appears to be a technical drawing for the F-STAr (Flow Sensor Test Article) pump that is the subject of a federal contract opportunity. The drawing provides details on the depth limits and dimensions of the pump, including a maximum liquid level of 75 inches and a maximum depth of 78.45 inches. The pump is designed to have an 8-inch and 10-inch 150-class ANSI flange pattern.
The related federal contract opportunity is for the design, fabrication, testing, and delivery of the F-STAr pump to Argonne National Laboratory. The solicitation number is 4-B176-Q-00517-00, and the evaluation will be based on lowest price and technical acceptability. The contractor will be required to perform design, fabrication, testing, documentation, and delivery of the pump in accordance with the technical, fabrication, and testing requirements specified in the solicitation. Interested offerors are required to submit a completed ANL-70 Request for Quotation, ANL-70B Pre-Award Information, and evidence of technical capability.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum and Acknowledgment Doc F-STAr.doc | DOC document | |
| Addendum and Acknowledgement Doc.doc | DOC document | |
| Enclosure 1 Instructions to Offerors_G4-135011.doc | DOC document | |
| Enclosure 2 ANL-70 Request for Quotation.doc | DOC document | |
| Enclosure 4 Specifications and Statement of Work.pdf | ||
| Enclosure 3 FSTAR Pump Supplier Evaluation Criteria rv6.pdf | ||
| G14642XD-1 REV01.pdf | ||
| Addendum and Acknowledgement Doc 2.doc | DOC document | |
| Appendix A-71COM-13-FEB-2023.PDF | ||
| Enclosure 1 Instructions to Offerors_G4-135011.doc | DOC document | |
| Enclosure 4 Specification Document.pdf | ||
| Addendum and Acknowledgement Doc.doc | DOC document | |
| Enclosure 2 ANL-70 Request for Quotation.doc | DOC document | |
| Enclosure 3 Evaluation Criteria.pdf | ||
| ANL-70 Request for Quotation.doc | DOC document | |
| G14642XD-2 REV00.pdf | ||
| Specification Document.pdf | ||
| Reps Certs ANL-70B (Blank).doc | DOC document | |
| G14642XD-1 REV00.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION A-A
DEPTH LIMITS
A A
A A
B B
C C
D D
DATE
PROJECT NO:PROJECT:
DESCRIPTION:
F-STAr
F-STAr Flange-Vessel Assembly
PART NUMBER:
G14642XD-2
REV
DATE
DATE
DO NOT SCALE DRAWING
SHEETSCALE
APVD/RELEASED
PROJECT MGR
GP LEADER
4/25/2024
DATE
DATE
SHEET SIZE
` .02
` .1
` .005
ALL DIMENSIONS ARE INCHES
RESPONSIBLE ENGINEER
CHECKED
` 1/2~ ` 1/64
ANGULAR TOL
.XXX
.XX
.X
J. Rein
REMOVE ALL BURRS AND SHARP EDGES
SURFACES TO BE IN ACCORDANCE
DRAWN BY
J. Rein
MATERIAL
DIMENSIONS & TOLERANCES IN
ACCORDANCE WITH LATEST ASME Y14.5M
WITH LATEST ANSI B46.1
UNLESS OTHERWISE NOTED
DECIMAL TOLERANCE
DATE
FRACTIONAL TOL
Argonne
NATIONAL LABORATORY
C
1 : 4
INV ENT OR 201 3 AJ B RE V O CT 2 014
RELEASED
STATUS:
ITEM NO. NEXT ASSEMBLY QTY. REQ'D.
4/25/2024
25.25
MAXIMUM LIQUID LEVEL
75.00
MAXIMUM DEPTH
n9.50 n11.50
28.75
MAXIMUM LIQUID LEVEL
78.45
MAXIMUM DEPTH
8-inch 150-class ANSI
Flange Pattern
10-inch 150-class ANSI
Flange Pattern