Atch_8_(L-4),_Seed_Project_Pricing_Template.xlsx
XLSX spreadsheet 35 KB Posted
- Attached to
- Painting and Coatings Services Federal contract opportunity
- Solicitation number
- FA9301-17-R-0008
About this file
Atch 8, Seed Project Pricing Template
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Seed Project Pricing
| PAINTING & COATINGS ID/IQ SOLICITATION | |||||
| FA9301-17-R-0008 | |||||
| SEED PROJECT PRICING TEMPLATE | |||||
| ELIN # | DESCRIPTION | UNIT OF MEASURE | PROPOSED PRICE* | QUANTITY | EXTENDED PRICE |
| EXTERIOR | |||||
| A001 | Apply Primer Coat (1 coat) includes surface prep | SF | $ - 0 | ||
| A002 | Apply Finish Coat to Walls, Soffits, Duct Work & Mech Equipment Exterior (2 coats) | SF | $ - 0 | ||
| A003 | Apply Finish Coat to Doors and Door Frames (2 coats) | SF | $ - 0 | ||
| A004 | Apply Finish Coat to Window Frames and Sash (2 coats) | SF | $ - 0 | ||
| A005 | Apply Finish Coat to Fascia including gutters and downspouts (2 coats) | SF | $ - 0 | ||
| A006 | Apply Finish Coats to Railings (2 coats) | LF | $ - 0 | ||
| A007 | Apply Finish Coat to Ladders, grills and Steel Stairs (2 coats) | SF | $ - 0 | ||
| A008 | Apply Coarse Texture Coat to match existing | SF | $ - 0 | ||
| A009 | Replace Metal Gutter and downspouts with pre-finished metal | LF | $ - 0 | ||
| A00A | Replace Rotted or Deteriorated Wood Fascia | SF | $ - 0 | ||
| A00B | Bold Helvitica numbers/letters | SF | $ - 0 | ||
| A00C | Stucco, 3 coat, 1" thick, including lath, metal and accessories (whole structure) | SY | $ - 0 | ||
| A00D | Stucco Repair, 3 coat, to match existing, including lath, metal and accessories (patching or whole wall <10 sy) | SY | $ - 0 | ||
| A00E | Install Pre-Finished (colored) Sheetmetal Siding complete finished installation | SF | $ - 0 | ||
| INTERIOR | |||||
| A00F | Apply Prime Coat (1 coat) includes surface prep | SF | $ - 0 | ||
| A00G | Interior walls, 2 coats | SF | $ - 0 | ||
| A00H | Interior ceilings, 2 coats | SF | $ - 0 | ||
| A00J | Interior Flat Door incl Frames and Trim, 2 coats painted | SF | $ - 0 | ||
| A00K | Interior Flat Door incl Frames and Trim, both sides, stained and 2 finished coats. Includes Surface Preparation. | SF | $ - 0 | ||
| A00L | Interior Louvered Doors, incl frame and trim, two finish coats | SF | $ - 0 | ||
| A00M | Interior Raised Panel Door incl Frames and Trim, 2 coats | SF | $ - 0 | ||
| A00N | Interior Raised Panel Door incl Frames and Trim, 2 finish coats | SF | $ - 0 | ||
| A00P | Windows, Interior Side, 2 finish coats | SF | $ - 0 | ||
| A00Q | Windows, Interior Side, 2 finish coats, over 6 lites | SF | $ - 0 | ||
| A00R | Grills | SF | $ - 0 | ||
| A00S | Trim (baseboards, casings, crowns, etc.), including surface preperation, up to 6" wide, painted or stained 2 coats | LF | $ - 0 | ||
| A00T | Drywall, patch repair, type, thickness, taped and textured to match existing, less than 32 SF, walls | SF | $ - 0 | ||
| A00U | Drywall, patch repair, type, thickness, taped and textured to match existing, greater than 32 SF, walls | SF | $ - 0 | ||
| A00V | Drywall, patch repair, type, thickness, taped and textured to match existing, less than 32 SF, ceiling | SF | $ - 0 | ||
| A00W | Drywall, patch repair, type, thickness, taped and textured to match existing, greater than 32 SF, ceiling | SF | $ - 0 | ||
| A00X | 1/2" or 5/8" Drywall, full wall installation on existing framing, taped, textured, corner beads and all accessories | SF | $ - 0 | ||
| A00Y | 1/2" or 5/8" Greenboard Drywall, full ceiling installation on existing framing, taped, textured, corner beads and all accessories | SF | $ - 0 | ||
| A00Z | Wall Paper Removal | SF | $ - 0 | ||
| A010 | Wall Texturing | SF | $ - 0 | ||
| A011 | Replace existing acoustic ceiling tiles | SF | $ - 0 | ||
| A012 | Replace damaged drywall partition including wood or steel studs (complete) | SF | $ - 0 | ||
| A013 | Skim-coat drywall surfaces with joint compound after wall covering removal | SF | $ - 0 | ||
| ABATEMENT | |||||
| A014 | Asbestos Abatement | SF | $ - 0 | ||
| A015 | Lead Based Paint Abatement | SF | $ - 0 | ||
| A016 | Asbestos/Lead paint/texture abatement Exterior | SF | $ - 0 | ||
| A017 | Lead containing/based road marking paint removal | SF | $ - 0 | ||
| A018 | Sampling and Testing for Lead and or Asbestos (per sample) | EA | $ - 0 | ||
| FLOOR COATING | |||||
| A019 | Epoxy Floor Coating with non-skid on concrete surface including minor surface preparation | SF | $ - 0 | ||
| A01A | Epoxy Floor Coating 85% solids with non-skid, chemical resistant, on concrete surface minor surface prep | SF | $ - 0 | ||
| A01B | Conductive elastomeric Floor Coating with non-skid on concrete surface with minor surface prep | SF | $ - 0 | ||
| A01C | Prep and re-seal expansion joints up to 1" width x 1" depth | LF | $ - 0 | ||
| A01D | Hardwood Flooring, sanding and finishing, 2 coats polyurethane | SF | $ - 0 | ||
| A01E | Aircraft hangar floor coating 100% solids with non-skid including minor surface preparation | SF | $ - 0 | ||
| A01F | Aircraft hangar floor striping <6" wide including surface prep | LF | $ - 0 | ||
| A01G | Electro-statice dissipative flooring system for laboratories | SF | $ - 0 | ||
| ROAD MARKINGS AND STRIPING | |||||
| A01H | Striping on concrete and asphalt with type 1 reflective beads, includes airfield, parking and roads, up to 4" | LF | $ - 0 | ||
| A01J | Striping on concrete and asphalt with type 3 reflective beads, includes airfield, parking and roads, up to 4" | LF | $ - 0 | ||
| A01K | Striping on concrete and asphalt with type 1 reflective beads, includes airfield, parking and roads, up to 12" | LF | $ - 0 | ||
| A01L | Striping on concrete and asphalt with type 3 reflective beads, includes airfield, parking and roads, up to 12" | LF | $ - 0 | ||
| A01M | Road markings paint letters, numbers, symbols, etc. with reflective beads | SF | $ - 0 | ||
| A01N | Road marking paint removal non-lead | SF | $ - 0 | ||
| A01P | Runway Markings with 12lb glass beads (per 100 square feet) | SF | $ - 0 | ||
| TANKS | |||||
| A01Q | Tanks, water/fuel exterior solid color (2 finish coats) | SF | $ - 0 | ||
| A01R | Tanks, water exterior checkerboard (2 finish coats) | SF | $ - 0 | ||
| A01S | Tanks, fuel interior | SF | $ - 0 | ||
| A01T | Tanks, water interior | SF | $ - 0 | ||
| A01U | Energy efficient paint for tank exteriors including prime, prep and two coats | SF | $ - 0 | ||
| A01V | Temporary Water Storage tanks (while existing water tank is painted) 5000 gal | MO | $ - 0 | ||
| INSPECTION | |||||
| A01W | Exterior Paint Inspection, includes condition of surface, life expectancy, square footage of painted areas (according to ELIN items) and recommendations | SF | $ - 0 | ||
| A01X | 4"-6" Epoxy wall cove base installed along with epoxy floor coatings | LF | $ - 0 | ||
| A01Y | Apply Anti-static wax to hangar floors to make new epoxy static resistant | SF | $ - 0 | ||
| A01Z | Concrete floor repairs, floating and patching 1/4" thickness | SF | $ - 0 | ||
| A020 | Drafting/Engineering layouts for parking and striping plans | SF | $ - 0 | ||
| A021 | Install 4" rubber cove base on walls | LF | $ - 0 | ||
| A022 | Install 6" rubber cove base on walls | LF | $ - 0 | ||
| FLOORING DEMOLITION | |||||
| A023 | Demo existing 12"x12" VCT flooring | SF | $ - 0 | ||
| A024 | Demo existing ceramic tile with thinset | SF | $ - 0 | ||
| A025 | Demo carpet including scraping | SF | $ - 0 | ||
| A026 | Bead-blast concrete floors | SF | $ - 0 | ||
| A027 | Concrete grinding, polishing with diamond floor grinder includes removal of epoxy flooring | MSF | $ - 0 | ||
| A028 | Hydro-blasting (water blasting) | SF | $ - 0 | ||
| A029 | Sand-blasting | SF | $ - 0 | ||
| TANK MAN-WAYS | |||||
| A02A | Cut and install new access man-door in tank to meet code (small including gasket) | EA | $ - 0 | ||
| A02B | Cut and install new access man-door in tank to meet new codes (large including gasket) | EA | $ - 0 | ||
| A02C | Confined space monitoring and rescue-ready team on standby when painting inside of tanks | DAY | $ - 0 | ||
| LIFT EQUIPMENT | |||||
| A02D | Swing-stage man-lift to 60ft with cables and 500# capacity | MO | $ - 0 | ||
| A02E | Scaffolding (1-5 stories) | CSF | $ - 0 | ||
| A02F | Two-man lift to 25ft height | MO | $ - 0 | ||
| A02G | 40' Boom Lift | MO | $ - 0 | ||
| A02H | 60' Boom Lift | MO | $ - 0 | ||
| A02J | 80' Boom Lift | MO | $ - 0 | ||
| MISCELLANEOUS | |||||
| A02K | Furniture moving (labor only - two men) to move appliances, furniture and equipment in order to paint the area (includes replacing items to their original location) | DAY | $ - 0 | ||
| A02L | Trim Tree Branches to allow painting when next to building (up to 24" dia.) | EA | $ - 0 | ||
| A02M | Trim Shrubbery around buildings to allow for painting (under 3ft shrub) | EA | $ - 0 | ||
| A02N | Chain Link Fence Rental (6ft ht) | LF | $ - 0 | ||
| A02P | Base sign road signs, 5'x4'x7'-6" high with wood framing and double posts | EA | $ - 0 | ||
| A02Q | Electrician labor (Journeyman Level) to disconnect equipment from shop floors for painting | MH | $ - 0 | ||
| A02R | Plumber labor (Journeyman Level) to disconnect fixtures from bathrooms for painting and flooring work | MH | $ - 0 | ||
| A02S | Power wash (1500-2500 psi) | SF | $ - 0 | ||
| A02T | Equipment Fuel | GAL | $ - 0 | ||
| A02U | Install Air Force Symbol 5' to 10' diameter (includes complete fabrication of symbol and preparation, priming, and installion of symbol with protective coating) | EA | $ - 0 | ||
| A02V | Install Air Force Symbol 11' to 20' diameter (includes complete fabrication of symbol and preparation, priming, and installion of symbol with protective coating) | EA | $ - 0 | ||
| A02W | Install Air Force Symbol 21' to 30' diameter (includes complete fabrication of symbol and preparation, priming, and installion of symbol with protective coating) | EA | $ - 0 | ||
| TOTAL | $ - 0 | ||||
| *The prices in this column must match the Offeror's proposed prices for Year 1 as listed on Attachment 5 (L-1) of their proposal. | |||||
| Contractor may remove unused ELINs if desired. |
FOR OFFICIAL USE ONLY
SEE FAR 2.101 AND 3.104
&P FA9301-17-R-0008 PAINTING AND COATINGS ID/IQ SOLICITATION
ATTACHMENT 8 (L-4)
SEED PROJECT PRICING TEMPLATE FOR OFFICIAL USE ONLY
SEE FAR 2.101 AND 3.104