Text version
42 10 20
SCALE IN FEET
FIRST FLOOR PLAN
Attachment 6 Floor Plan, Site Plan, Site Elevations
FA9301-14-R-0011 - Amendment 0002
6 7 8 9 10
112 1
S
SW
SE
E
W
NW
NE
N
DEMO &
FLOOR
PLANS
A-1
JW
1/4"=1'-0"
FLOOR PLAN
GENERAL NOTES
1. CONTRACTOR SHALL COMPLY WITH ENVIRONMENTAL MANAGEMENT (EM) REQUIRED
CHECKLIST.
2. BARRICADE CONSTRUCTION AREA TO PREVENT HAZARDOUS CONDITIONS.
3. KEEP THE AREA CLEAN AT ALL TIMES AND REMOVE ALL WASTE IN THE APPROPRIATE
MANNER.
4. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
KEY NOTES
INSTALL NEW STOREFRONT WITH SLIDING DOOR AND MOTION DETECTOR.4
DRAWING NUMBER
SHEET OF
DRAWN BY
CHECKED
T.O. #
DATE
SCALE
SHEET TITLE
SABER DIVISION
EDWARDS AFB, CA 93524
227 N ROSAMOND BLVD
FA
C
IL
IT
IE
S
M A N A G E R
A P P R O V A L S
IG
N A
TU
R E
ENGINEERING, INC.
661-258-4540
EDWARDS
ACE
C
IV
IL
E N G
IN
E E R
IN
G
A P P R O V A L S
IG
N A
TU
C O N
TR
A C
TI
N G
A P P R O V A L S
IG
N A
TU
D A
TE
D A
TE
D A
TE
R P R E N
TR
A N C E D O O R S
B U
IL
D
IN
G
NUMBER
REVISION
DATE
FI
R E
D E P A R
TM
E N T A P P R O V A L S
IG
N A
TU
R E
D A
TE
APPROVED
AS-NOTED
04/03/06
MA
SF
AS-BUILT
JW
6 FLOAT EXISTING BLOCK WALL IN ENTRY AND TEXTURE TO MATCH EXISTING INTERIOR
WALLS.
7 TEXTURE COAT EXISTING CEILING AND WALLS OF ENTRY.
8 PROVIDE 1 COAT OF PRIMER AND 2 COATS OF PAINT TO NEW DRYWALL AND
EXISTING WALLS AND CEILINGS.
KEY PLAN
1/4"=1'-0"
DEMO PLAN
DEMO KEY NOTES
EXISTING INTERIOR ENTRANCE DOORS AND GLASS TO REMAIN.1
REMOVE EXISTING EXTERIOR STOREFRONT AND DOORS.2
RELOCATE FIRE ALARM PULL STATION AS REQUIRED.
INSTALL NEW SURFACE MOUNT LIGHT FIXTURE.
REMOVE EXISTING INTERIOR CLOSET DOOR.3
INSTALL NEW DRYWALL AND WOOD DOOR FOR NEW CLOSET.
CLEAN AND REPAIR EXISTING DOORS AS REQUIRED.11
Attachment 6 Floor Plan, Site Plan, Site Elevations
FLOOR PLAN
NEWDEMO
6 7 8 9 10
3 5
Attachment 6 Floor Plan, Site Plan, Site Elevations
42 10 20
SCALE IN FEET
FIRST FLOOR PLAN
BUILDING 2850
04/15/04DATE:
PROJECT NO. EDWARDS AFB
FIGURE
N
Attachment 6 Floor Plan, Site Plan, Site Elevations
Attachment 6 Floor Plan, Site Plan, Site Elevations
Attachment 6 Floor Plan, Site Plan, Site Elevations
| Model |
| 1ST FLR |
| Vestibule Addition.pdf |
| Model |
| A-1 |
File details come from the government source that posted it. Updated .