Attachment_5_(Hazardous_Material_Survey)_-_Amendment_0002.pdf
PDF 1 MB Posted
- Attached to
- Simplified Acquisition of Base Engineering Requirements (SABER) Federal contract opportunity
- Solicitation number
- FA9301-14-R-0011
About this file
Attachment 5 (Hazardous Material Survey) - Amendment 0002
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 5 Hazardous Material Survey
FA9301-14-R-0011 - Amendment 0002
Asbestos Detected
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0139001
NVLAP#101926-0
Client ID
Client:
Address: 412 TW/CEPM
EDWARDS AFB CA 93524
EDWARDS AFB
Date Received: 03/27/2014
03/27/2014Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 03/26/2014
EPA Method: Project Name: BLDG 2850
Submitted By: MICHELE LaCOMBAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
03/27/2014Date Reported:
EPA 600/R-93/116
Asbestos Type
225 N. ROSAMOND BLVD
NoLAYER 1 Paint, Beige
None Detected0139001-001 2850-CE-01 Carbonates
Binder/Filler
100%
YesLAYER 2 Texture / Paint, Green Note: Unable to separate adjacent layers
Chrysotile 3%
Carbonates Mica Binder/Filler
97%
NoLAYER 1 Paint, Beige
None Detected0139001-002 2850-CE-02 Carbonates
Binder/Filler
100%
YesLAYER 2 Texture / Paint, Green Note: Unable to separate adjacent layers
Chrysotile 2%
Carbonates Mica Binder/Filler
98%
Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent.
Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.
Analyst - Kenneth Scheske Signatory - Lab Director - Kurt Kettler
Attachment 5 Hazardous Material Survey
EMC LABS, INC.
9830 South 51st Street, Suite B-109 / PHOENIX, ARIZONA 85044 / 480-940-5294 or 800-362-3373 / FAX 480-893-1726 emclab@emclabs.com
ANALYST: QA COORDINATOR:
Jason Thompson Kurt Kettler
Rev. 11/30/08
LEAD (Pb) IN PAINT CHIP SAMPLES
EMC SOP METHOD #L01/1 EPA SW-846 METHOD 7420
EMC LAB #: L51864 DATE RECEIVED: 03/27/14
CLIENT: Edwards AFB REPORT DATE: 03/27/14
DATE OF ANALYSIS: 03/27/14
CLIENT ADDRESS: 412th CE/CENMP 225 N. Rosamond Blvd.
Edwards AFB, CA 93524
P.O. NO.:
PROJECT NAME: Samples taken at Bldg. 2850 PROJECT NO.:
EMC #
L51864-
SAMPLE
DATE /14
CLIENT
SAMPLE #
DESCRIPTION
REPORTING
LIMIT
(%Pb by weight)
%Pb BY
WEIGHT
1 03/26 2850-CE-1L Paint – Beige / Green 0.010 0.044
2 03/26 2850-CE-2L Paint – Beige / Green 0.010 0.039 ^ = Dilution Factor Changed * = Excessive Substrate May Bias Sample Results BRL = Below Reportable Limits # = Very Small Amount Of Sample Submitted, May Affect Result
This report applies to the standards or procedures identified and to the samples tested only. The test results are not necessarily indicative or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. Unless otherwise noted, all quality control analyses for the samples noted above were within acceptable limits.
Where it is noted that a sample with excessive substrate was submitted for laboratory analysis, such analysis may be biased. The lead content of such sample may, in actuality, be greater than reported. EMC makes no warranty, express or implied, as to the accuracy of the analysis of samples noted to have been submitted with excessive substrate. Resampling is recommended in such situations to verify original laboratory results.
These reports are for the exclusive use of the addressed client and are rendered upon the condition that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. Samples not destroyed in testing are retained a maximum of sixty (60) days.