03 Attachment L-03 Roofing Contract Evaluation.xlsx
XLSX spreadsheet 20 KB Posted
- Solicitation number
- FA890326R0009
About this file
This is a roofing contract evaluation template designed for vendors responding to the Department of the Air Force's Roofing, Repair, and Replacement Follow-on (R3F) Multiple Award Task Order Contract (MATOC). The template requires vendors to provide company information, point of contact details, and document their capabilities across seventeen distinct roof types specified in the Unified Facilities Guide Specifications (UFGS).
Vendors must indicate their ability to install each roof type, provide evidence of manufacturer certifications for their installers, and confirm their capacity to meet warranty requirements ranging from 10 to 30 years depending on the roof type. The roof types evaluated include Cold Liquid-Applied Reinforced Polymethyl Methacrylate, Asphalt Shingles (both Architectural Laminated and Three-Tab variants), Slate Shingles, Concrete and Clay Tile Roofing, Metal Roof Panels, Built-Up Asphalt Roofing, Modified Bituminous Membrane Roofing, EPDM, PVC, TPO, Protected Membrane Roofing, Mesh Reinforced Elastomeric Coating, Sprayed Polyurethane Foam, and Standing Seam options in both steel and aluminum. For each roof type where vendors claim capability, they must provide project references including customer contact information, project location, brief descriptions, roof slope type per UFC 3-110-03, manufacturer names, square footage, and project completion dates. This evaluation mechanism supports the Air Force's five-year IDIQ contract vehicle for roofing services across multiple geographic regions.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Vendor Name: | Vendor Point of Contact: | Vendor Email: | Vendor Phone #: | ||||||||||||||||||
| Roof Types | Vendor Capabilities | Projects for Reference | |||||||||||||||||||
| Type Number | UFGS | Roof Type | Are you able to install this roof type (Yes/No)? | Manufacturer Certification Requirement? | UFGS Certification Paragraph | Do your installers have required certification (Yes/No)? | Warranty Requirement (Years) | UFGS Warranty Paragraph | Can you meet warranty requirement (Yes/No)? | Region(s)/State(s) Proposed to Work | Customer Company | POC at customer company | POC phone # | POC email address | Project Location (City/State) | Brief Project Description | Roof Slope Type per UFC 3-110-03 | Manufacturer Name | Square Footage (ft2) | Date of Project Completion | Notes |
| 1 | 07 18 16 | Cold Liquid-Applied Reinforced Polymethyl Methacrylate Roofing | Yes | 1.4.2 | 20 | 1.7 | |||||||||||||||
| *2A | 07 31 13 | Asphalt Shingles (Architectural Laminated Shingles) | Yes | 1.4.2 | 30 | 1.6.1 | |||||||||||||||
| *2B | 07 31 13 | Asphalt Shingles (Three-Tab Shingles) | Yes | 1.4.2 | 25 | 1.6.1 | |||||||||||||||
| 3 | 07 31 26 | Slate Shingles | No | 1.3 | 30 | 1.6.2 | |||||||||||||||
| 4 | 07 32 13 | Concrete Tile Roofing Replacement or Repair | No | 1.5.2 | 20 | 1.8.2 | |||||||||||||||
| 5 | 07 32 14 | Clay Tile Roofing Replacement or Repair | No | 1.3.1 | 20 | 1.6.2 | |||||||||||||||
| 6 | 07 41 13 | Metal Roof Panels | Yes | 1.3.2 | 20 | 1.6.1 | |||||||||||||||
| 7 | 07 41 13.16 | Clay Tile Roofing Replacement or Repair | Yes | 1.4.1 | 20 | 1.6 | |||||||||||||||
| 8 | 07 51 13 | Built-Up Asphalt Roofing | Yes | 1.4.2 | 20 | 1.7.1 | |||||||||||||||
| 9 | 07 52 00 | Modified Bituminous Membrane Roofing | Yes | 1.6.2 | 20 | 1.9.1 | |||||||||||||||
| 10 | 07 53 23 | Ethylene-Propylene-Diene-Monomer (EPDM) Roofing | Yes | 1.4.2 | 20 | 1.7.1 | |||||||||||||||
| 11 | 07 54 19 | Polyvinyl Chloride Roofing | Yes | 1.5.2 | 20 | 1.10.1 | |||||||||||||||
| 12 | 07 54 23 | Thermoplastic-Polyolefin (TPO) Roofing | Yes | 1.4.2 | 20 | 1.8.1 | |||||||||||||||
| 13 | 07 55 00 | Protected Membrane Roofing (PMR) | Yes | 1.4.2 | 20 | 1.7.1 | |||||||||||||||
| 14 | 07 56 00.60 | Mesh Reinforced Elastomeric Coating (MERC) Roofing | Yes | 1.4.2 | 10 | 1.7.1 | |||||||||||||||
| 15 | 07 57 13 | Sprayed Polyurethane Foam (SPF) Roofing | Yes | 1.4.2 | 10 | 1.7.1 | |||||||||||||||
| 16 | 07 61 14 | Steel Standing Seam Roofing | Yes | 1.6.4 | 20 | 1.7.1 | |||||||||||||||
| 17 | 07 61 15 | Aluminum Standing Seam Roofing | Yes | 1.6.1 | 20 | 1.8.1 | |||||||||||||||
| *NOTE - 2A and 2B is a single roofing type, if both are filled in, they will only count as a single entry. |