Atch 5 - WARPS Equip Classification Maintenance Action Sheets.pdf

PDF 997 KB Posted

Attached to
CE Facility and Equipment Support to Intelligence and Research and Development Activities
Solicitation number
FA8601-10-R-0038
Issued by

About this file

Atch 5 WARPS Equip Classifications Maintenance Action Sheets

View the file

Other files

File Type Posted
Exhibit A - Price List Breakdown of Services by Customer —
Amendment 0006 - Signed Copy.pdf PDF
Vendor Q A 8 - 17 Jun 10.pdf PDF
Vendor Q A 7 - 17 Jun 10.pdf PDF
Amendment 0005 - Signed Copy.pdf PDF
Exhibit D - Master WARPS Price List Qty Variation Worksheets by Lab - Revised 15 Jun 10.xls XLS spreadsheet
Atch 4 - WARPS Equip Classification - Revised 15 Jun 10.pdf PDF
Atch 3 DBA WD OH100029 Mod 8 4 Jun 10.txt TXT text file
Vendor Q A 6 - 15 Jun 10.pdf PDF
Vendor Q A 5 - 13 Jun 10.pdf PDF
Vendor Q A 4 - 10 Jun 10.pdf PDF
Amendment 0004 - Signed Copy.pdf PDF
Exhibit D - Master WARPS Price List Qty Variation Worksheets by Lab - Revised 26 May 10.xls XLS spreadsheet
Vendor Q A 3 - 1 June 2010.pdf PDF
Lab 3 - Gov't Provided Tools.xls XLS spreadsheet
Vendor Q A 2.pdf PDF
Lab 8 - Gov't Provided Tools.pdf PDF
Lab 7 - Gov't Provided Tools.xls XLS spreadsheet
Lab 9 - Gov't Provided Tooling.pdf PDF
Lab 6 - Gov't Provided Tools.pdf PDF
Exhibit D - Master WARPS Price List Qty Variation Worksheets by Lab - Revised 24 May 10.xls XLS spreadsheet
Amendment 0003 - Signed Copy.pdf PDF
Exhibit B - Repair Replacement Labor Rates by Labor Category - Corrected 19 May 10.xls XLS spreadsheet
Atch 1 - Revised PWS - 21 May 10.pdf PDF
Atch 5 WARPS Equip Class MAS Instructions - Revised 21 May 10.pdf PDF
Vendor Q A 1 - 21 May 10.pdf PDF
12 May 10 Site Visit Minutes with Atchs.pdf PDF
Amendment 0002 - Signed Copy.pdf PDF
Amendment 0001 - Signed Copy.pdf PDF
Atch 2 - SCA Wage Determination 2005-2419 Rev 9 14 Aug 09.txt TXT text file
Exhibit D - Master WARPS Price List Qty Variation Worksheets by Lab.xls XLS spreadsheet
Exhibit A - Price List Breakdown of Services by Customer —
Atch 8 - Past Performance Questionnaire.doc DOC document
SF 33 - Request for Proposal 7 May 10.pdf PDF
Atch 1 - PWS - 26 Feb 10.pdf PDF
Atch 6 - Master Equip List by Lab - 9 Feb 10 - Protected.xls XLS spreadsheet
Atch 3 - DBA General Decision OH100029 30 Apr 10.txt TXT text file
Exhibit B - Repair Replacement Labor Rates by Labor Category.xls XLS spreadsheet
Atch 7 - WPAFB_BFS_Compiled_2009-11-25.pdf PDF
Atch 4 - WARPS Equip Classification.pdf PDF
Exhibit C - Parts Material List - 19 Mar 10.xls XLS spreadsheet
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Maintenance Action Sheet

WRIGHT‐PATTERSON AIR FORCE BASE

Instruction Code 1010‐A Date Last Edited 12/27/99

1010 SUMP PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: PEDESTAL OR DECK PLATE MOUNTED, FLOAT SWITCH CONTROLLED

( ) CHECK WIRING CONNTECTIONS/INSULATION

( ) CLEAN/TIGHTEN ALL ELECTRICAL CONNECTIONS

Instruction Code 1010‐M Date Last Edited 12/9/99

1010 SUMP PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: PEDESTAL OR DECK PLATE MOUNTED, FLOAT SWITCH CONTROLLED

( ) CHECK PUMP/COMPONENTS FOR PROPER OPERATION, MAKE NECESSARY ADJUSTMENTS

( ) CLEAN/CHECK FLOAT CONTROL

( ) CLEAN UNIT/SUMP

Instruction Code 1010‐Q Date Last Edited 12/9/99

1010 SUMP PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: PEDESTAL OR DECK PLATE MOUNTED, FLOAT SWITCH CONTROLLED

( ) CHECK MOTOR CONTROLLER

( ) CHECK/CORRECT (MINOR) CORROSION SPOTS

Instruction Code 1010‐S Date Last Edited 2/16/00

1010 SUMP PUMP ‐ SEMIANNUAL MAINTENANCE

( ) PERFORM IN ACCORDANCE W/MANUFACTURER INSTRUCTIONS

Instruction Code 1011‐A Date Last Edited 12/9/99

1011 SUMP PUMP OR SEWAGE PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: DECK PLATE OR PEDESTAL MOUNTED, FLOAT SWITCH, CONTROLLED MECHANICAL

ALTERNATOR

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) CLEAN/TIGHTEN ALL ELECTRICAL CONNECTIONS

Instruction Code 1011‐M Date Last Edited 12/9/99

1011 SUMP PUMP OR SEWAGE PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: DECK PLATE OR PEDESTAL MOUNTED, FLOAT SWITCH, CONTROLLED MECHANICAL

ALTERNATOR

( ) CHECK PUMP/COMPONENTS FOR PROPER OPERATION, MAKE NECESSARY ADJUSTMENTS

( ) CLEAN/CHECK FLOAT CONTROL

( ) CLEAN UNIT/SUMP

June 11, 2009 [Type text] P a g e | 1

Instruction Code 1011‐Q Date Last Edited 12/9/99

1011 SUMP PUMP OR SEWAGE PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: DECK PLATE OR PEDESTAL MOUNTED, FLOAT SWITCH, CONTROLLED MECHANICAL

ALTERNATOR

( ) CHECK MOTOR CONTROLLER

( ) CHECK/CORRECT (MINOR) CORROSION SPOTS

Instruction Code 1012‐A Date Last Edited 4/11/00

1012 SUMP PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: SUBMER SUMP PUMP

( ) PULL PUMP/INSPECT IMPELLER, FLOAT ASSEMBLY/PIPES

Instruction Code 1012‐M Date Last Edited 4/11/00

1012 SUMP PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: SUBMER SUMP PUMP

( ) CHECK PUMP/COMPONENTS FOR PROPER OPERATION, MAKE NECESSARY ADJUSTMENTS

( ) CLEAN UNIT/SUMP

( ) INSPECT/PERFORM MINOR CORROSION

( ) CHECK, TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

Instruction Code 1020‐A Date Last Edited 12/9/99

1020 CIRCULATING PUMP OVER 20 HP ‐ ANNUAL MAINTENANCE

APPLIES TO: PACKED SHAFT SEAL, COUPLING DRIVE, BASE MOUNTED

( ) CHECK, TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) TEARDOWN, INSPECT/OVERHAUL PUMP AS NECESSARY

( ) TIGHTEN/REPLACE LOOSE, MISSING/DAMAGED NUT, BOLTS/SCREWS

( ) CLEAN AREA AROUND UNIT (100 SQ. FT.)

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK MOTOR WINDINGS FOR INSULATION BREAKDOWN

( ) BLOW OUT WINDINGS/SCREENS

( ) CHECK THERMAL INSULATION OF PUMP

Instruction Code 1020‐M Date Last Edited 12/9/99

1020 CIRCULATING PUMP OVER 20 HP ‐ MONTHLY MAINTENANCE

APPLIES TO: PACKED SHAFT SEAL, COUPLING DRIVE, BASE MOUNTED

( ) CLEAN UNIT, PUMP/MOTOR

( ) CHECK OIL LEVEL IN BEARING ASSEMBLY

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

June 11, 2009 [Type text] P a g e | 2

Instruction Code 1020‐Q Date Last Edited 12/9/99

1020 CIRCULATING PUMP OVER 20 HP ‐ QUARTERLY MAINTENANCE

APPLIES TO: PACKED SHAFT SEAL, COUPLING DRIVE, BASE MOUNTED

( ) INSPECT/ERFORM MINOR CORROSION CONTROL

( ) CHECK MOTOR CONTROLLER

( ) CHECK OPERATING VOLTAGE/CURRENT DRAW

( ) LUBE COUPLING, MOTOR/PUMP BEARING, IF NEEDED

Instruction Code 1020‐W Date Last Edited 12/9/99

1020 CIRCULATING PUMP OVER 20 HP ‐ WEEKLY MAINTENANCE

APPLIES TO: PACKED SHAFT SEAL, COUPLING DRIVE, BASE MOUNTED

( ) CHECK/PUMP/COMPONENTS FOR PROPER OPERATON, MAKE NECESSARY ADJUSTMENTS

( ) VISUALLY INSPECT FOR LEAKS

( ) CHECK FOR UNUSUAL VIBRATIONS AND NOISES

Instruction Code 1021‐A Date Last Edited 12/9/99

1021 CIRCULATING PUMP OVER 20 H.P. OR LESS ‐ ANNUAL MAINTENANCE

APPLIES TO: PACKED SHAFT SEAL, COUPLING DRIVE, BASE MOUNTED

( ) CHECK, TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

( ) TEARDOWN, INCSPECT/OVERHAUL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNITE

( ) CHECK OPERATING VOLTAGE/CURRENT DRAW

( ) CHECK, TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

( ) TIGHTEN/REPLACE LOOSE, MISSING/DAMAGED NUTS, BOLTS/SCREWS

( ) CLEAN AREA AROUND UNIT (PER 100 SQ.FT.)

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK MOTOR INDINGS FOR INSULATION BREAKDOWN

( ) BLOW OUT MOTOR WINDINGS/SCREENS

( ) CHECK TERMAL INSULATION OF PUMP

Instruction Code 1021‐M Date Last Edited 12/9/99

1021 CIRCULATING PUMP OVER 20 H.P. OR LESS ‐ MONTHLY MAINTENANCE

APPLIES TO: PACKED SHAFT SEAL, COUPLING DRIVE, BASE MOUNTED

( ) CHECK PUMP COMPONENTS FOR PROPER OPERATION MAKE NECESSARRY ADJUST/REPAIRS

CLEAN UNIT, PUMP/MOTOR

( ) INSPECT/ADJUST PACKING GLAND FOR SHAFT COOLING

( ) CHECK/CLEAN PUMP DRAIN

( ) CHECK OIL LEVEL IN BEARING ASSEMBLY

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

June 11, 2009 [Type text] P a g e | 3

Instruction Code 1021‐Q Date Last Edited 12/9/99

1021 CIRCULATING PUMP OVER 20 H.P. OR LESS ‐ QUARTERLY MAINTENANCE

APPLIES TO: PACKED SHAFT SEAL, COUPLING DRIVE, BASE MOUNTED

( ) INSPECT.PERFORM MINOR CORROSION

( ) CHECK MOTOR CONTROLLER, REPAIR IF NEEDED

( ) CHECK OPERATING VOLTAGE/CURRENT DRAW

( ) LUBE COUPLING, MOTOR/PUMP BEARINGS IF NEEDED

Instruction Code 1021‐W Date Last Edited 12/21/99

CIRCULATING PUMP 20 HP OR LESS ‐ WEEKLY MAINTENANCE

APPLIES TO: Packed shaft seal coupling drive, base mounted

( ) VISUALLY INSSECT FOR LEAKS

( ) CHECK FOR UNUSUAL VIBBRATIONS

Instruction Code 1022‐A Date Last Edited 12/9/99

1022 CIRCULATING PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAL, COUPLING DRIVCE

( ) CHECK TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) TEARDOWN, INSPECT.OVERHAUL PUMP AS NECESSARY

( ) TIGHTEN/REPLACE LOOSE, MISSING/DAMAGED NUTS, BOLTS/SCREWS

( ) CLEAN AREA AROUND UNIT (PER 100 SQ. FT.)

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK MOTOR WINDINGS FOR INSULATION BREAKDOWN

( ) BLOW OUT MOTOR WINDINGS/SCREENS

( ) CHECK TERMAL INSULATION OF PUMP

Instruction Code 1022‐M Date Last Edited 12/9/99

1022 CIRCULATING PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAL, COUPLING DRIVCE

( ) CLEAN UNIT, PUMP.MOTOR

( ) CHECK OIL LEVEL IN BEAING ASSEMBLY

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

Instruction Code 1022‐Q Date Last Edited 12/9/99

1022 CIRCULATING PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAL, COUPLING DRIVCE

( ) INSPECT.PERFORM MINOR CORROSION CONTROL

June 11, 2009 [Type text] P a g e | 4

( ) CHECK MOTOR CONTROLLER

( ) CHECK OPERATING VOLTAGE/CURRENT DRAW

( ) LUBE COUPLING MOTOR/PUMP BEARING IF NEEDED

Instruction Code 1022‐S Date Last Edited 02/18/00

1022 CIRCULATING PUMP ‐ SEMIANNUAL MAINTENANCE

( ) PERFORM IN ACCORDANCE W/MANUFACTURER’S INSTRUCTIONS

Instruction Code 1022‐W Date Last Edited 12/9/99

1022 CIRCULATING PUMP ‐ WEEKLY MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAL, COUPLING DRIVCE

( ) CHECK PUMP.COMPONENTS FOR PROPER OPERATION, MAKE NECESSARY ADJUSTMENTS

( ) VISUALLY INSPECT FOR LEAKS

( ) CHECK FOR UNUSUAL VIBRATIONS OR NOISES

Instruction Code 1023‐A Date Last Edited 12/9/99

1023 CIRCULATING PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAL, COUPLING DRIVCE

( ) TEARDOWN, INSPECT/OVERHAUL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) TIGHTEN/REPLACE LOOSE, MISSING/DAMAGED NUTS, BOLTS/SCREWS

( ) CLEAN AREA AROUND UNIT (PER 100 SQ. FT.)

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK MOTOR WINDINGS FOR INSULATION BREAKDOWN

( ) BLOW OUT MOTOR WINDINGS/SCREENS

Instruction Code 1023‐M Date Last Edited 12/9/99

1023 CIRCULATING PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAL, CLOSE COUPLED OR DIRECT DRIVE

( ) INSPECT/LUB COSE OR SPRING COUPLING

( ) CHECK PUMP MOTOR/COMPON FOR PROPER OPERATION MAKE NECESSARY ADJUSTMENT REPAIR

( ) CLEAN UNIT, PUMP/MOTOR

( ) CHECK OIL LEVEL IN BEARING ASSEMBLY

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

Instruction Code 1023‐Q Date Last Edited 12/9/99

1023 CIRCULATING PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAL, COUPLING DRIVCE

( ) INSPECT/PERFORM MINOR CORROSION CONTROL

June 11, 2009 [Type text] P a g e | 5

( ) CHECK MOTOR CONTROLLER, REPAIR IF NEEDED

( ) CHECK OPERATING VOLTAGE/CURRENT DRAW

( ) LUBE COUPLING, MOTOR/PUMP BEARING IF NEEDED

Instruction Code 1023‐S Date Last Edited 12/9/99

1023 CIRCULATING PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAI~, COUPLING DRIVCE

( ) CHECK, TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

Instruction Code 1023‐W Date Last Edited 12/9/99

1023 CIRCULATING PUMP ‐ WEEKLY MAINTENANCE

APPLIES TO: MECHANICAL SHAFT SEAIJ, COUPLING DRIVCE

( ) VISUALLY INSPECT FOR LEAKS

( ) CHECK FOR UNUSUAL VIBRATIONS OR NOISES

Instruction Code 1024‐A Date Last Edited 12/10/99

1024 CENTRIFUGAL BOOST PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: VARIABLE SPPED, FREQUENCY CONTROLLED INCLUDES FREQUENCY CONVERTER

( ) CHECK OPERATING VOLTAGE/CURRENT DRAW

( ) CHECK, TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

( ) TEARDOWN, INSPECT/OVERHAUL PUMP AS NECESSARY

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) TIGHTEN/REPLACE LOOSE, MISSING/DAMAGED NUTS, BOLTS/SCREWS

( ) CLEAN AREA AROUND UNIT (PER 100 SQ. FT.)

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK MOTOR WINDINGS FOR INSULATION BREAKDOWN

( ) BLOW OUT MOTOR WINDINGS/SCREENS

( ) CHECK THERMAL INSULATION OF PUMP

( ) CHECK ROTATING ELEMENT OF MECHANICAL SEAL COMPLETELY, REPLACE IF NECESSARY

( ) MEASURE TOTAL DYNAMIC SUCTION/DISCHARGE HEAD TO SEE IF THERE IS INTERNAL DEPOSIT

BUILD UP

( ) CHECK/REPLACE COPPER LINES ON PRESSURE SWITCH

( ) CHECK/CLEAN SUCTION DIFFUSER

Instruction Code I024‐D Date Last Edited 12/30/99

1024 CENTRIFUGAL BOOST PUMP ‐ DAILY MAINTENANCE

APPLIES TO: VARIABLE SPEED, FREQUENCY CONTROLLED INCLUDES FREQUENCY CONVERTER

( ) CHECK PUMP/COMPONENTS FOR PROPER OPERATION, MAKE NECESSARY ADJUSTMENT

( ) LOG SUCTION/DISCHARGE PRESSURES

( ) INSPECT MECHANICAL SEALS FOR LEAKS

June 11, 2009 [Type text] P a g e | 6

( ) VISUALLY INSPECT PUMP FOR LEAKS

NOTE EACH DATE, TIME, MANHOURS, & INDIVIDUAL PERFORMING EACH DAILY MAINTENANCE BELOW:

Instruction Code 1024‐M Date Last Edited 12/10/99

1024 CENTRIFUGAL BOOST PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: VARIABLE SPPED, FREQUENCY CONTROLLED INCLUDES FREQUENCY CONVERTER

( ) CHECK FOR UNUSUAL VIBRATIONS/NOISES

( ) CLEAN UNIT (PUMP/MOTOR)

( ) CHECK BEARING TEMP NOT TO EXCEED 180 DEGREE F

Instruction Code 1024‐Q Date Last Edited 12/10/99

1024 CENTRIFUGAL BOOST PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: VARIABLE SPPED, FREQUENCY CONTROLLED INCLUDES FREQUENCY CONVERTER

( ) INSPECT/PERFORM MINOR CORROSION CONTROL

( ) CHECK MOTOR CONTROLLER

( ) CHECK/ADD GREASE TO PUMP BEARINGS

Instruction Code 1024‐S Date Last Edited 12/10/99

1024 CENTRIFUGAL BOOST PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: VARIABLE SPPED, FREQUENCY CONTROLLED INCLUDES FREQUENCY CONVERTER

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

Instruction Code 1030‐A Date Last Edited 12/10/99

1030 CONDENSATE PUMP AND TANK UNIT ‐ ANNUAL MAINTENANCE

APPLIES TO: FLOAT SWITCH CONTROLLED

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) TEARDOWN, INSPECT/OVERHAUL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

Instruction Code 1030‐M Date Last Edited 12/10/99

1030 CONDENSATE PUMP AND TANK UNIT ‐ MONTHLY MAINTENANCE

APPLIES TO: FLOAT SWITCH CONTROLLED

( ) INSPECT FOR NOISE/LEAKS, SEALS, COUPLING (ETC.)

( ) CHECK UNIT FOR PROPER OPERATION

( ) CHECK ALTERNATOR‐FLOAT SWITCH CONTROL

Instruction Code 1030‐Q Date Last Edited 12/10/99

June 11, 2009 [Type text] P a g e | 7

1030 CONDENSATE PUMP AND TANK UNIT ‐ QUARTERLY MAINTENANCE

APPLIES TO: FLOAT SWITCH CONTROLLED

( ) CLEAN UNIT CHECK FOR CORROSION

( ) CHECK MOTOR CONTROLLER

( ) DRAIN/FLUS CONDENSATE TANK, CLEAN STRAINER

Instruction Code 1030‐S Date Last Edited 12/10/99

1030 CONDENSATE PUMP AND TANK UNIT ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: FLOAT SWITCH CONTROLLED

( ) LUBRICATE MOTOR BEARINGS

Instruction Code 1031‐A Date Last Edited 12/10/99

1031 CONDENSATE PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: DUPLEX PUM AND TANK UNIT ‐ FLOAT SWITCH CONTROLLED MECHANICAL ALTERNATOR

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) TEARDOWN, INSPECT/OVERHAUL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) CHECK OPERATING VOLTAGE/CURRENT DRAW

( ) CHECK, TIGHTEN/CLEAN ALL ELECTRICAL CONNECTIONS

( ) TIGHTEN/REPLACE LOSSE, MISSION/DAMAGED NUTS, BOLTS/SCREWS

( ) CLEAN AREA AROUND UNIT (PER 100 SQ. FT.)

( ) CHECK MOTOR WINDINGS FOR INSULATION BREAKDOWN

( ) BLOW OUT MOTOR WINDINGS/SCREENS

( ) REPACK STUFFING BOX

Instruction Code 1031‐D Date Last Edited 12/10/99

1031 CONDENSATE PUMP ‐ DAILY MAINTENANCE

APPLIES TO: DUPLEX PUM AND TANK UNIT ‐ FLOAT SWITCH CONTROLLED MECHANICAL ALTERNATOR

( ) VISUALLY INSPECT/OVERHAUL PUMP

Instruction Code 1031‐M Date Last Edited 12/10/99

1031 CONDENSATE PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: DUPLEX PUM AND TANK UNIT ‐ FLOAT SWITCH CONTROLLED MECHANICAL ALTERNATOR

( ) INSPECT FOR NOISE/LEAKS, SEALS, and COUPLING (ETC)

( ) CHECK UNIT FOR PROPER OPERATION

( ) CHECK ALTERNATOR‐FLOAT SWITCH CONTROL

( ) CHECK FOR UNUSUAL VIBRATIONS/NOISES

( ) CLEAN UNIT (PUMP/MOTOR)

June 11, 2009 [Type text] P a g e | 8

( ) CHECK DRAIN HOLES OF PUMP TO SEE IF CLEAR

Instruction Code 1031‐Q Date Last Edited 12/10/99

1031 CONDENSATE PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: DUPLEX PUM AND TANK UNIT ‐ FLOAT SWITCH CONTROLLED MECHANICAL ALTERNATOR

( ) CLEAN UNIT, CHECK FOR CORROSION

( ) CHECK MOTOR CONTROLLER

( ) DRAIN/FLUSH CONDENSATE TANK CLEAN STRAINER

( ) INSPECT/PERFORM MINOR CORROSION CONTROL

( ) CHECK/ADD GREASE TO PUMP BEARINGS

Instruction Code 1031‐S Date Last Edited 12/10/99

1031 CONDENSATE PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: DUPLEX PUM AND TANK UNIT ‐ FLOAT SWITCH CONTROLLED MECHANICAL ALTERNATOR

( ) LUBRICATE MOTOR BEARINGS

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

Instruction Code 1031‐W Date Last Edited 12/10/99

1031 CONDENSATE PUMP ‐ WEEKLY MAINTENANCE

APPLIES TO: DUPLEX PUM AND TANK UNIT ‐ FLOAT SWITCH CONTROLLED MECHANICAL ALTERNATOR

( ) INSPECT PACKING GLAND FOR LEAKS

Instruction Code 1032‐A

1032 CONDENSATE PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: PUMP ONLY‐CENTRIFUGAL OR REGENERATIVE (TURBINE)

( ) CHECK OPERATING VCOLTAGE/CURRENT DRAW

( ) CHECK/TIGHTEN ALL ELECTRICAL CONNECTIONS

( ) TEARDOWN, INSPECT/OVERHAUL PUMP AS NECESSARY

( ) PRFORM CORROSION CONTROL ON COMPLETE UNIT

( ) TIGHTEN/REPLACE LOOSE, MISSING/DAMAGED NUTS, BOLTS/SCREWS

( ) CLEAN AREA AROUND UNIT (PER 100 SQ. FT.)

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK MOTOR WINDINGS FOR INSULATION BREAKDOWN

( ) BLOW OUT MOTOR WINDINGS

( ) DRAIN/FLUSH CONDENSATE TANK

Instruction Code 1032‐D Date Last Edited 12/10/99

1032 CONDENSATE PUMP ‐ DAILY MAINTENANCE

APPLIES TO: PUMP ONLY‐CENTRIFUGAL OR REGENERATIVE (TURBINE)

June 11, 2009 [Type text] P a g e | 9

( ) CHECK PUMP/COMPONETS FOR PROPER OPERATION, MAKE NECESSARY ADJUSTMENTS

( ) INSPECT MECHANICAL SEAL FOR LEAKS

( ) VISUALLY INSPECT PUMP FOR LEAKS

( ) CHECK FOR UNUSUAL VIBRATIONS/NOISES

Instruction Code I032‐M Date Last Edited 12/10/99

1032 CONDENSATE PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: PUMP ONLY‐CENTRIFUGAL OR REGENERATIVE (TURBINE)

( ) CLEAN UNIT (PUMP/MOTOR)

Instruction Code 1032‐Q Date Last Edited 12/10/99

1032 CONDENSATE PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: PUMP ONLY‐CENTRIFUGAL OR REGENERATIVE (TURBINE)

( ) INSPECT/PERFORM MINOR CORROSION CONTROL

( ) CHECK MOTOR CONTROLLER

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

Instruction Code 1032‐S Date Last Edited 12/10/99

1012 CONDENSATE PUMP ‐ SEMI‐ALLUAL MAINTENANCE

APPLIES TO: PUMP ONLY‐CENTRIFUGAL OR REGENERATIVE (TURBINE)

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

Instruction Code 1032‐W Date Last Edited 12/10/99

1032 CONDENSATE PUMP ‐ WEEKLY MAINTENANCE

APPLIES TO: PUMP ONLY‐CENTRIFUGAL OR REGENERATIVE (TURBINE)

( ) CHECK ALTERNATING FLOAT SWITCH TO SEE IF PUMPS ARE ALTERNATING

Instruction Code 1033‐A Date Last Edited 12/10/99

1033 CONDENSATE PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: DUPLEX EJECTOR (VACUUM CONDENSATE RETURN WITH TANK ‐ EJECTOR AND

CONDENSATE PUMPS, MECHANICAL ALTERNATORS, FLOAT SWITCH CONTROLLED, CONDENSATE PUMPS

PRESSURE (VACUUM) SWITCH CONTROLLED

( ) CHECK WIRING/INSULATION

( ) TEARDOWN, INSPECT/OVERHAUL PUMP

Instruction Code 1033‐D 1033 CONDENSATE PUMP ‐ DAILY MAINTENANCE Date Last Edited 12/10/99

APPLIES TO: DUPLEX EJECTOR (VACUUM CONDENSATE RETURN WITH TANK ‐ EJECTOR AND

June 11, 2009 [Type text] P a g e | 10

CONDENSATE PUMPS, MECHANICAL ALTERNATORS, FLOAT SWITCH CONTROLLED, CONDENSATE PUMPS

PRESSURE (VACUUM) SWITCH CONTROLLED

( ) DAILY CHECK UNIT FOR PROPER OPERATION

Instruction Code 1033‐M Date Last Edited 12/11/99

1033 CONDENSATE PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: DUPLEX EJECTOR (VACUUM CONDENSATE RETURN WITH TANK ‐ EJECTOR AND

CONDENSATE PUMPS, MECHANICAL ALTERNATORS, FLOAT SWITCH CONTROLLED, CONDENSATE PUMPS

PRESSURE (VACUUM) SWITCH CONTROLLED

( ) CHECK CONDENSATE RETURN TEMPERATURE/PRESSURE

( ) CHECK SHAFT SEALS FOR LEAKS/NOISE

( ) CHECK ALTERNATOR FOR OPERATION

( ) CHECK FLOAT/VACUUM SWITCH OPERATION

Instruction Code 1033‐Q Date Last Edited 12/10/99

1033 CONDENSATE PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: DUPLEX EJECTOR (VACUUM CONDENSATE RETURN WITH TANK ‐ EJECTOR AND

CONDENSATE PUMPS, MECHANICAL ALTERNATORS, FLOAT SWITCH CONTROLLED, CONDENSATE PUMPS

PRESSURE (VACUUM) SWITCH CONTROLLED

( ) PHYSICALLY REMOVE, REPAIR, INSPECT, CLEAN/REASSEMBLE MULTI‐JET NOZZLE/CHECK VALVE

ASSEMBLY

( ) CLEAN UNIT/CHECK FOR CORROSION

( ) DRAIN/FLUSH TANK CHAMBERS, CLEAN STRAINER

( ) CHECK MOTOR CONTROLLER

Instruction Code 1033‐S Date Last Edited 12/10/99

1033 CONDENSATE PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: DUPLEX EJECTOR (VACUUM CONDENSATE RETURN WITH TANK ‐ EJECTOR AND

CONDENSATE PUMPS, MECHANICAL ALTERNATORS, FLOAT SWITCH CONTROLLED, CONDENSATE PUMPS

PRESSURE (VACUUM) SWITCH CONTROLLED

( ) LUBE MOTOR BEARINGS IF NEEDED

Instruction Code 1035‐A Date Last Edited 12/10/99

1035 VACUUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: VACUUM PUMP

( ) INSPECT MOTOR STARTERS

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) INSPECT/OVERHAUL UNIT IF NEEDED

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

June 11, 2009 [Type text] P a g e | 11

Instruction Code 1035‐M Date Last Edited 12/10/99

1035 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: VACUUM PUMP

( ) CHECK UNIT FOR PROPER OPERATION

( ) INPSECT NOISE, VIBRATION, WATER LEVEL

( ) CHECK PUMP SEALS FOR LEAKS

Instruction Code 1035‐Q Date Last Edited 12/10/99

1035 VACUUM PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: VACUUM PUMP

( ) CLEAN UNIT EXTERIOR

( ) CHECK/PERFORM MINOR CORROSION

Instruction Code 1035‐S Date Last Edited 12/10/99

1035 VACUUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: VACUUM PUMP

( ) LUBE PUMP/MOTOR BEARINGS IF NEEDED

Instruction Code 1036‐A Date Last Edited 12/10/99

1036 VACUUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: DIRECT DRIVE VANE TYPE ‐ OIL SEALED

( ) CHANGE PUMP FLUID, CLEAN INLETCONE

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) TEARDOWN, INSPECT/OVERHAUL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

Instruction Code 1036‐M Date Last Edited 12/10/99

1036 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: DIRECT DRIVE VANE TYPE ‐ OIL SEALED

( ) CHECK UNIT FOR PROPER OPERATION‐REPAIR AS NEEDED

( ) INSPECT‐NOISE, VIBRATION, LEAKS, PERFORMANCE

( ) CHECK UNIT CHECK CORROSION‐PERFORM MINOR CORROSION

Instruction Code 1036‐Q Date Last Edited 12/10/99

1036 VACUUM PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: DIRECT DRIVE VANE TYPE ‐ OIL SEALED

June 11, 2009 [Type text] P a g e | 12

( ) CHECK UNIT, CHEC COROSION‐PERFORM MINOR CORROSION

Instruction Code 1036‐S Date Last Edited 12/10/99

1036 VACUUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: DIRECT DRIVE VANE TYPE ‐ OIL SEALED

( ) LUBE PUMP MOTOR

Instruction Code 1040‐A Date Last Edited 12/10/99

1040 VACUUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE

( ) CHANGE PUMP OIL

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) TEARDOWN, INSPECT/OVERHAL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

Instruction Code 1040‐M Date Last Edited 12/10/99

1040 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE

( ) CHECK FOR PROPER OPERATION

( ) INPSECT OIL LEVEL/CONDITION

( ) INSPECT‐NOISE, VIBRATION, LEAKS

( ) CHECK BELT FOR WEAR/TENSION, CHECK SHEAVES

Instruction Code 1040‐Q Date Last Edited 12/10/99

1040 VACUUM PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE

( ) CLEAN UNIT, PERFORM CORROSION CONTROL (MINOR)

( ) CHECK MOTOR CONTROLLER

Instruction Code 1040‐S Date Last Edited 12/10/99

1040 VACUUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE

( ) LUBE MOTOR BEARINGS

Instruction Code 1041‐A Date Last Edited 12/10/99

1041 VACUUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE, WATER COOLED

June 11, 2009 [Type text] P a g e | 13

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) TEARDOWN/INSPECT PUMP IF NEEDED

( ) PERFORM CORROSION CONTROL ON UNIT

Instruction Code 1041‐M Date Last Edited 12/10/99

1041 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE, WATER COOLED

( ) INSPECT FOR: NOISE, VIBRATION, LEAKS

( ) CHECK OIL LEVEL/CONDITION OF OIL, CHANGE OIL IF NEEDED

( ) CHECK BELTS/SHEAVES

( ) CHECK COOLING WATER VALVE

Instruction Code 1041‐Q Date Last Edited 12/10/99

1041 VACUUM PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE, WATER COOLED

( ) CLEAN UNIT/CHECK FOR MINOR CORROSION

Instruction Code 1041‐S Date Last Edited 12/10/99

1041 VACUUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE, WATER COOLED

( ) CHANGE PUMP OIL

( ) CHECK MOTOR CONTROLLER

( ) LUBE MOTOR BEARINGS AS NEEDED

Instruction Code 1041‐W Date Last Edited 12/10/99

1041 VACUUM PUMP ‐ WEEKLY MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED, BELT DRIVE, WATER COOLED

( ) WEEKLY CHECK UNIT FOR PROPER OPERATION

Instruction Code 1042‐A Date Last Edited 12/10/99

1042 VACUUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) BELT DRIVE

( ) CHECK WIRING INSULATION BREAKDOWN

( ) CHECK MOTOR WINDINGS INSULATION FOR BREAKDOWN

( ) TEARDOWN, INSPECT/OVERHAUL PUMP IF NECESSARY

Instruction Code 1042‐D Date Last Edited 12/10/99

1042 VACUUM PUMP ‐ DAILY MAINTENANCE

June 11, 2009 [Type text] P a g e | 14

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) BELT DRIVE

( ) INSPECT FOR UNUSUAL NOISES OR VIBRATION

( ) INSPECT PUMP FOR LEAKS

( ) CHECK OPERATING OIL PSI

Instruction Code 1042‐M Date Last Edited 12/10/99

1042 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) BELT DRIVE

( ) CHECK UNIT FOR PROPER OPERATION, MAKE ADJUSTMENT IF NECESSARY

( ) CHECK H2O CONTROL VALVE

( ) CHECK VOLTAGE/CURRENT DRAW

( ) CHECK FOR HOT SPOTS ON HEAD PLATES/CYCLINDER

( ) CHECK ALL VALVES FOR POSITIVE SHUT OFF

Instruction Code 1042‐Q Date Last Edited 12/10/99

1042 VACUUM PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) BELT DRIVE

( ) CHANGE OIL FILTER

( ) CHECK/CLEAN SOLENOID VALVE (OIL/H20)

( ) CHECK/ADD GREASE TO MOTOR

( ) CHECK MOTOR CONTROLLER

Instruction Code 1042‐S Date Last Edited 12/10/99

1042 VACUUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) BELT DRIVE

( ) CHECK WIRING INSULATION BREAKDOWN

Instruction Code 1042‐W Date Last Edited 12/10/99

1042 VACUUM PUMP ‐ WEEKLY MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) BELT DRIVE

( ) CHECK CONDITION OF OIL

( ) CHECK BELTS

Instruction Code 1043‐A Date Last Edited 12/11/99

1043 VACUUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) COUPLING OR GEAR BOX DRIVE

June 11, 2009 [Type text] P a g e | 15

( ) MEASURE MOTOR INSULATION RESISTANCE

( ) CHANGE LUBE OIL/FILTER

( ) TEARDOWN, INSPECT.OVERHAUL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK WINDINGS FOR INSULATION BREAKDOWN

( ) DISMANTLE UNIT COMPLETELY (REFER TO MANUAL)

( ) INSPECT MECHANICAL SEALS

( ) FLUSH H20 JACKETS

( ) INSPECT/CLEAN CYLINDER BORES/CLINDER HEAD FARES

Instruction Code 1043‐D Date Last Edited 12/11/99

1043 VACUUM PUMP ‐ DAILY MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) COUPLING OR GEAR BOX DRIVE

( ) DRAIN/BLOW OUT RECEIVER, COOLER/INTERCONNECTING PIPING

Instruction Code 1043‐M Date Last Edited 12/11/99

1043 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) COUPLING OR GEAR BOX DRIVE

( ) CHECK UNIT FOR PROPER OPERATION, REPAIR AS NEEDED

( ) INSPECT‐NOISE, VIBRATION, LEAKS

( ) CHECK OIL LEVEL/CONDITION‐CHANGE IF REQUIRED

( ) CHECK SHAFT SEAL FOR LEAKS, CHECK COUPLING

( ) CHECK OPERATING TEMPERATURE/PRESSURES

( ) CHECK WATER CONTROL VALVE

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

( ) INSPECT.CLEAN INLET H20 STRAINER

( ) INSPECT/CLEAN INTAKE FILTER

Instruction Code 1043‐Q Date Last Edited 12/11/99

1043 VACUUM PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) COUPLING OR GEAR BOX DRIVE

( ) CHECK OIL COOLER, GEAR REDUCER OIL LEVEL

( ) CLEAN UNIT, CHECK CORROSION, PERFORM MINOR CORROSION

( ) CHECK MOTOR CONTROLLER

( ) CHECK OPERATING VOLTAGE/CURRENT

( ) CHECK/CLEAN SOLENOID VALVE (OIL/H20)

( ) CHECK/ADD GREASE TO MOTOR

Instruction Code 1043‐S Date Last Edited 12/11/99

1043 VACUUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

June 11, 2009 [Type text] P a g e | 16

APPLIES TO: ROTARY, MECHANICAL (ROOTS TYPE) COUPLING OR GEAR BOX DRIVE

( ) LUBE MOTOR BEARINGS/COUPLING‐IF NEEDED

( ) CHECK ALL WIRING CONNECTIONS

( ) CHECK ROTOR BLADE FOR WEAR (REFER TO MANUAL)

( ) CLEAN COOLERS (REFER TO MANUAL)

Instruction Code 1044‐A Date Last Edited 12/11/99

1044 VACUUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: LIQUID RING (WATER) TYPE, BELT DRIVE

( ) CHECK WIRING FOR INSULATION BREAKDOWN

( ) CHECK MOTOR WINDING INSULATION FOR BREAKDOWN

( ) TEARDOWN, INSPECT/OVERHAUL PUMP IF NECESSARY

Instruction Code 1044‐D Date Last Edited 12/11/99

1044 VACUUM PUMP ‐ DAILY MAINTENANCE

APPLIES TO: LIQUID RING (WATER) TYPE, BELT DRIVE

( ) INSPECT FOR UNUSUAL NOISE/VIBRATION

( ) INSPECT PUMP FOR LEAKS

Instruction Code 1044‐M Date Last Edited 12/11/99

1044 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: LIQUID RING (WATER) TYPE, BELT DRIVE

( ) CHECK UNIT FOR PROPER OPERATION, MAKE ADJUSTMENTS IF NECESSARY

( ) CHECK H2O CONTROL VALVE

( ) CHECK COUPLING FOR WEAR/ALIGNMENT

( ) CHECK VOLTAGE/CURRENT DRAW

( ) CHECK/MAINTAIN PROPER H2O LEVEL IN VACUUM TANK

Instruction Code 1044‐Q Date Last Edited 12/11/99

1044 VACUUM PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: LIQUID RING (WATER) TYPE, BELT DRIVE

( ) CHECK/CLEAN SOLENOID VALVE

( ) CHECK/ADD GREASE TOP PUMP/MOTOR

( ) CHECK MOTOR CONTROLLER

Instruction Code 1044‐S Date Last Edited 12/11/99

1044 VACUUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: LIQUID RING (WATER) TYPE, BELT DRIVE

June 11, 2009 [Type text] P a g e | 17

( ) CHECK WIRING CONNECTIONS, TIGHTEN IF NECESSARY

Instruction Code 1046‐M` Date Last Edited 12/11/99

1046 VACUUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: EJECTOR TYPE, WATER POWERED

( ) AS PER MANUFACTURER SPECIFICATIONS

Instruction Code 1047‐A

1047 VACCUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: VANE TYPE, OIL‐LESS, AIR COOLED, BELT DRIVE

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

Instruction Code 1047‐M Date Last Edited 12/11/99

1047 VACCUM PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: VANE TYPE, OIL‐LESS, AIR COOLED, DIRECT DRIVE

( ) CHECK UNIT FOR PROPER OPERATION

( ) CHECK UNIT FOR NOISE/VIBRATION

( ) CLEAN SUCTION BOWL

Instruction Code 1047‐S Date Last Edited 12/11/99

1047 VACCUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: VANE TYPE, OIL‐LESS, AIR COOLED, DIRECT DRIVE

( ) CHECK WIRING CONNECTION/INSULATION

( ) CLEAN UNIT CHECK FOR CORROSION (MINOR)

Instruction Code 1048‐A

1048 VACUUM PUMPING STATION ‐ ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL FORE PUMP/PUMPS, DIFFUSION OR KINETIC PUMP, REFRIGERATION

SYSTEM, HEATING (BAKE OUT) SYSTEM, WITH INSTRUMENTATION AND CONTROLS

( ) CLEAN UNIT‐PERORM CORROSION

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) CHANGE FORE PUMP OIL

( ) OVERHAUL IF REQUIRED

Instruction Code 1048‐M Date Last Edited 12/11/99

1048 VACUUM PUMPING STATION ‐ MONTHLY MAINTENANCE

June 11, 2009 [Type text] P a g e | 18

APPLIES TO: MECHANICAL FORE PUMP/PUMPS, DIFFUSION OR KINETIC PUMP, REFRIGERATION

SYSTEM, HEATING (BAKE OUT) SYSTEM, WITH INSTRUMENTATION AND CONTROLS

(NOTE: REFER TO SERVICE MANUAL BEFORE SERVICING)

( ) CHECK OIL LEVEL/CONDITION IN FORE PUMPS

( ) INSPECT‐NOISE, VIRATION, LEAKS

( ) CHECK DIFFUSION PUMP OIL

( ) CHECK REFRIGERATION SYSTEM OIL/REFRIGERANT LEAKS

( ) CHECK FORE PUMP BELTS FOR WEAR/TENSION

( ) CHECK HEATING (BRAKE OUT) SYSTEM OPERATION

( ) CHECK DIFFUSION PUMP COOLING WATER FLOW

( ) CHECK REFRIGERANT SIGHT GLASS‐CHARGE, MOISTURE

( ) CHECK UNIT CONTROL OPERATION

( ) PERFORM MINOR CORROSION

( ) CHECK UNIT FOR PROPER OPERATION

Instruction Code 1048‐Q Date Last Edited 12/11/99

1048 VACUUM PUMPING STATION ‐ QUARTERLY MAINTENANCE

APPLIES TO: MECHANICAL FORE PUMP/PUMPS, DIFFUSION OR KINETIC PUMP, REFRIGERATION SYSTEM, HEATING (BAKE OUT) SYSTEM, WITH INSTRUMENTATION AND CONTROLS

( ) CHECK FORE PUMP SHEAVES FOR WEAR, ALIGNMENT

( ) CHECK CONDENSER/FAN‐CLEAN AS REQUIRED

Instruction Code 1048‐S Date Last Edited 12/11/99

1048 VACUUM PUMPING STATION ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL FORE PUMP/PUMPS, DIFFUSION OR KINETIC PUMP, REFRIGERATION

SYSTEM, HEATING (BAKE OUT) SYSTEM, WITH INSTRUMENTATION AND CONTROLS

( ) LUBE FORE PUMP MOTOR BEARINGS‐IF NEEDED

( ) LUBE CONDENSER FAN MOTOR BEARINGS‐IF NEEDED

Instruction Code 1049‐A Date Last Edited 12/11/99

1049 VACCUM PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED DIRECT DRIVE THROUGH COUPLING OR

GEAR REDUCER (GEAR LUBE COMMON TO VACUUM PUMP OIL)

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) CHANGE PUMP/GEAR REDUCER OIL

( ) OVERHAUL PUMP

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

Instruction Code 1049‐M Date Last Edited 12/11/99

1049 VACCUM PUMP ‐ MONTHLY MAINTENANCE

June 11, 2009 [Type text] P a g e | 19

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED DIRECT DRIVE THROUGH COUPLING OR

GEAR REDUCER (GEAR LUBE COMMON TO VACUUM PUMP OIL)

( ) CHECK UNIT FOR PROPER OPERATION‐REPAIR AS NEEDED

( ) INSPECT, NOISE, VIBRATION, LEAKS

( ) CHECK OIL LEVEL/CONDITION, CHANGE IF REQUIRED

Instruction Code 1049‐S Date Last Edited 12/11/99

1049 VACCUM PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: MECHANICAL, ROTARY PISTON TYPE, OIL SEALED DIRECT DRIVE THROUGH COUPLING OR

GEAR REDUCER (GEAR LUBE COMMON TO VACUUM PUMP OIL)

( ) CLEAN UNIT, PERFORM MINOR CORROSION

( ) LUBE PUMP MOTOR‐AS NEEDED

Instruction Code 1050‐A Date Last Edited 12/11/99

1050 CHEMICAL PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: WATER TREATMENT CHEMICAL FEED, VARIABLE SPEED AND STROKE, SOLENOID DRIVE

( ) PERFORM CORROSION CONTROL

Instruction Code 1050‐D Date Last Edited 12/11/99

1050 CHEMICAL PUMP ‐ DAILY MAINTENANCE

APPLIES TO: WATER TREATMENT CHEMICAL FEED, VARIABLE SPEED AND STROKE, SOLENOID DRIVE

( ) DAILY INSPECT FOR LEAKS (DELIVERY)

( ) ADJUST SPEED/STROKE (AS NEEDED)

Instruction Code 1050‐M

1050 CHEMICAL PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: WATER TREATMENT CHEMICAL FEED, VARIABLE SPEED AND STROKE, SOLENOID DRIVE

OPERATE FULL SPEED/STROKE POR 10 MINUTES

( ) INSPECT CHECK VALVE FOR LEAKS

Instruction Code 1050‐Q Date Last Edited 12/11/99

10S0 CHEMICAL PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO: WATER TREATMENT CHEMICAL FEED, VARIABLE SPEED AND STROKE, SOLENOID DRIVE

( ) CHECK WIRING CONNECTION/INSULATION

Instruction Code 1050‐W Date Last Edited 12/11/99

June 11, 2009 [Type text] P a g e | 20

1050 CHEMICAL PUMP ‐ WEEKLY MAINTENANCE

APPLIES TO: WATER TREATMENT CHEMICAL FEED, VARIABLE SPEED AND STROKE, SOLENOID DRIVE

( ) WEEKLY CLEAN UNIT

Instruction Code 1055‐D Date Last Edited 12/11/99

1055 CHEMICAL FEED PUMP CONTROL ‐ DAILY MAINTENANCE

APPLIES TO: PH OR CONDUCTIVITY CONTROL, WATER TREATMENT FOR COOLING TOWER

( ) ADD CHEMICALS, TEST PH, CW‐3/CONDUCTIVITY

( ) CHECK FOR PROPER OPERATION

( ) CALIBRATE CONTROL (AS REQUIRED)

Instruction Code 1055‐M Date Last Edited 12/11/99

1055 CHEMICAL FEED PUMP CONTROL ‐ MONTHLY MAINTENANCE

APPLIES TO: PH OR CONDUCTIVITY CONTROL, WATER TREATMENT FOR COOLING TOWER

( ) INVENTORY CHEMICAL SUPPLIES

Instruction Code 1055‐W Date Last Edited 12/11/99

1055 CHEMICAL FEED PUMP CONTROL ‐ WEEKLY MAINTENANCE

APPLIES TO: PH OR CONDUCTIVITY CONTROL, WATER TREATMENT FOR COOLING TOWER

( ) CLEAN PH, CONDUCTIVITY, CORROSION PROBLEMS (AS NEEDED)

Instruction Code 1056‐D

1056 CHEMICAL FEED PUMP CONTROL AND RECORDER ‐ DAILY MAINTENANCE

APPLIES TO: PH, CONDUCTIVITY CONTROLS INHIBITOR, ACID FEED, BLOWDOWN, BIOCIDE

( ) DAILY CHECK UNIT FOR PROPER OPERATION

( ) DAILY CALIBRATE CONTROLS

( ) DAILY INSPECTS FOR LEAKS

Instruction Code 1056‐M Date Last Edited 12/11/99

1056 CHEMICAL FEED PUMP CONTROL AND RECORDER ‐ MONTHLY MAINTENANCE

APPLIES TO: PH, CONDUCTIVITY CONTROLS INHIBITOR, ACID FEED, BLOWDOWN, BIOCIDE

( ) INVENTORY CHEMICAL SUPPLIES

( ) CHECK WATER USAGE

Instruction Code 1056‐W Date Last Edited 12/11/99

1056 CHEMICAL FEED PUMP CONTROL AND RECORDER ‐ WEEKLY MAINTENANCE

June 11, 2009 [Type text] P a g e | 21

APPLIES TO: PH, CONDUCTIVITY CONTROLS INHIBITOR, ACID FEED, BLOWDOWN, BIOCIDE

( ) CLEAN SENSING PROBE

( ) CLEAN STRAINER

( ) CHECK ALARM SYSTEM

( ) CHECK BLOW DOWN VALVE/STRAINER

Instruction Code 1060‐A Date Last Edited 12/11/99

1060 HYDRAULIC PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: AXIAL PISTON VARIABLE DISPLACEMENT ‐ MOTOR DRIVEN

( ) CHECK MOTOR CONTROLLER OPERATING VOLTAGE/CURRENT

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) OVERHAUL PUMP IF NEEDED

( ) PERFORM CORROSION CONTROL ON UNIT

Instruction Code 1060‐M Date Last Edited 12/11/99

1060 HYDRAULIC PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: AXIAL PISTON VARIABLE DISPLACEMENT ‐ MOTOR DRIVEN

( ) CHECK UNIT FOR PROPER OPERATION

( ) INSPECT FOR LEAKS

( ) CLEAN UNIT

Instruction Code 1060‐Q Date Last Edited 12/11/99

1060 HYDRAULIC PUMP ‐ QUARTERLY MAS

( ) PERFORM IN ACCORDANCE W/MANUFACTURER'S INSTRUCTIONS

Instruction Code 1060‐S Date Last Edited 12/11/99

1060 HYDRAULIC PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: AXIAL PISTON VARIABLE DISPLACEMENT ‐ MOTOR DRIVEN

( ) LUBE MOTOR BEARINGS CHECK/LUBE COUPLING IF NEEDED

Instruction Code 1063‐A Date Last Edited 12/11/99

1063 FUEL PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO:

( ) CHANGE PUMP LUBRICANT

( ) INSPECT WIRING CONNECTIONS/INSULATION

( ) CLEAN EXTERIOR

( ) PERFORM CORROSION CONTROL ON UNIT

June 11, 2009 [Type text] P a g e | 22

( ) OVERHAUL PUMP IF NEEDED

Instruction Code 1063‐M Date Last Edited 12/11/99

1063 FUEL PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO:

( ) CHECK UNIT FOR PROPER OPERATION

( ) INSPECT NOISE, VIBRATION, LEAKS

Instruction Code 1063‐Q Date Last Edited 12/11/99

1063 FUEL PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO:

( ) INSPECT COUPLING FOR WEAR, ALIGNMENT

( ) CHECK MOTOR STARTER

( ) CHECK PUMP LUBRICANT LEVEL

Instruction Code 1063‐S Date Last Edited 12/11/99

1063 FUEL PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO:

( ) CHECK RELIEF VALVE OPERATION

( ) LUBE MOTOR BEARINGS IF NEEDED

Instruction Code 1064‐A Date Last Edited 12/11/99

1064 FUEL PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO:

( ) INSPECT MOTOR STARTER

( ) LUBE MOTOR BEARINGS IF NEEDED

( ) CHANGE PUMP LUBRICANT

( ) INSPECT WIRING CONNECTIONS/INSULATION

( ) CLEAN EXTERIOR

( ) CHECK/PERFORM CORROSION ON UNIT

( ) OVERHAUL PUMP IF NEEDED

Instruction Code 1064‐M Date Last Edited 12/11/99

1064 FUEL PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO:

( ) CHECK UNIT FOR PROPER OPERATION

( ) INSPECT NOISE, VIBRATION, LEAKS

June 11, 2009 [Type text] P a g e | 23

Instruction Code 1064‐Q Date Last Edited 12/11/99

1064 FUEL PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO:

( ) INSPECT COUPLINGS FOR WEAR, ALIGNMENT

( ) CHECK PUMP LUBRICANT LEVEL

Instruction Code 1064‐S Date Last Edited 12/11/99

1064 FUEL PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO:

( ) CHECK GEAR REDUCER LUBE LEVEL

( ) CHECK RELIEF VALVE OPERATION

Instruction Code I065‐A Date Last Edited 12/11/99

1065 FUEL PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO:

( ) LUBE PUMP BEARINGS

Instruction Code 1065‐M Date Last Edited 12/11/99

1065 FUEL PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO:

( ) CHECK UNIT FOR PROPER OPERATION

( ) INSPECT NOISE, VIBRATION, LEAKS

Instruction Code 1065‐Q Date Last Edited 12/11/99

1065 FUEL PUMP ‐ QUARTERLY MAINTENANCE

APPLIES TO:

( ) INSPECT COUPLING FOR WEAR/ALIGNMENT

Instruction Code 1065‐S Date Last Edited 12/11/99

1065 FUEL PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO:

( ) INSPECT MOTOR STARTER

( ) RUN VARIABLE SPEED DRIVE THROUGH FULL SPEED RANGE

( ) LUBE SPEED REDUCER BEARINGS

Instruction Code 1070‐M Date Last Edited 12/11/99

June 11, 2009 [Type text] P a g e | 24

1070 PROGRESSIVE CAVITY PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: MOYNO TYPE, BELT DRIVE

( ) CHECK UNIT FOR PROPER OPERATION

( ) CHECK FOR LEAKS, SHAFT SEAL, CHECK COUPLING

Instruction Code 1070‐S Date Last Edited 12/11/99

1070 PROGRESSIVE CAVITY PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: MOYNO TYPE, BELT DRIVE

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) LUBE MOTOR BEARINGS

( ) LUBE PUMP BEARINGS

( ) CLEAN UNIT

Instruction Code 1071‐A Date Last Edited 12/11/99

1 71 PORTABLE PUMP ‐ ANNUAL MAINTENANCE

APPLIES TO: VANE TYPE PUMP

( ) PERFORM CORROSION CONTROL

( ) OVERHAUL PUMP IF NEEDED

Instruction Code 1071‐M Date Last Edited 12/11/99

1071 PORTABLE PUMP ‐ MONTHLY MAINTENANCE

APPLIES TO: VANE TYPE PUMP

( ) CHECK UNIT FOR PROPER OPERATION

( ) CHECK FOR LEAKS, SHAFT SEALS, COUPLING

Instruction Code 1071‐S Date Last Edited 12/11/99

1071 PORTABLE PUMP ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: VANE TYPE PUMP

( ) CHECK ALL ELECTRICAL CONNECTIONS

( ) LUBE MOTOR BEARING/CLEAN UNIT

Instruction Code 1110‐M Date Last Edited 12/11/99

1110 WATER HEATER ‐ MONTHLY MAINTENANCE

APPLIES TO: STEAM, THERMOSTATIC CONTROL

( ) CHECK FOR PROPER OPERATION

( ) CHECK/OPERATE SAFETY VALVE

June 11, 2009 [Type text] P a g e | 25

( ) CHECK STEAM CONTROL VALVE

( ) CHECK CONDENSATE TRAP/STRAINER

( ) INSPECT‐WATER TEMPERATURE, CHECK FOR LEAKS

Instruction Code 1110‐S Date Last Edited 12/11/99

1110 WATER HEATER ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: STEAM, THERMOSTATIC CONTROL

( ) FLUSH TANK

( ) CLEAN HEAT EXCHANGER

( ) PERFORM (MINOR) CORROSION CONTROL

Instruction Code 1111‐A Date Last Edited 12/11/99

1111 WATER HEATER ‐ ANNUAL MAINTENANCE

APPLIES TO: ELECTRIC, THERMOSTATIC CONTROL

( ) CHECK WIRING CONNECTIONS/INSULATION

Instruction Code 1111‐M Date Last Edited 12/11/99

1111 WATER HEATER ‐ MONTHLY MAINTENANCE

APPLIES TO: ELECTRIC, THERMOSTATIC CONTROL

( ) CHECK AMPS/WATER TEMPERATURE

Instruction Code 1111‐Q Date Last Edited 12/11/99

1111 WATER HEATER ‐ QUARTERLY MAINTENANCE

APPLIES TO: ELECTRIC, THERMOSTATIC CONTROL

( ) INSPECT‐WATER TEMPERATURE‐LEAKS

Instruction Code 1111‐S Date Last Edited 12/11/99

1111 WATER HEATER ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: ELECTRIC, THERMOSTATIC CONTROL

( ) CHECK/ OPERATE SAFETY VALVE

Instruction Code 1111‐W Date Last Edited 12/11/99

1111 WATER HEATER ‐ WEEKLY MAINTENANCE

APPLIES TO: ELECTRIC, THERMOSTATIC CONTROL

( ) CHECK FOR LEAKS

June 11, 2009 [Type text] P a g e | 26

Instruction Code 1120‐A Date Last Edited 12/11/99

1120 WATER SOFTENER ‐ ANNUAL MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, AUTOMATIC REGENERATION

( ) TEARDOWN/INSPECT SOLDMATIC VALVE FOR SEAL/SEAT WEAR

Instruction Code 1120‐D Date Last Edited 12/11/99

1120 WATER SOFTENER ‐ DAILY MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, AUTOMATIC REGENERATION

( ) DAILY CHECK OUTPUT WATER HARDNESS/PH AS REQUIRED

Instruction Code 1120‐M Date Last Edited 12/11/99

1120 WATER SOFTENER ‐ MONTHLY MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, AUTOMATIC REGENERATION

( ) CHECK UNIT FOR PROPER OPERATION‐REPAIR AS NEEDED

( ) CHECK CYCLE OPERATION AS REQUIRED

( ) CHECK SYSTEM FOR LEAKS

( ) CHECK DIP SWITCHES FOR TIMER SETTINGS

Instruction Code 1120‐Q Date Last Edited 12/11/99

1120 WATER SOFTENER ‐ QUATERLY MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, AUTOMATIC REGENERATION

( ) CHECK/ADJUST BRINE NEEDLE VALVE ON SOLDMATIC VALVE

( ) CHECK SOLENOID VALVES FOR WEAR/CORROSION

( ) TEARDOWN/CHECK AQUAMATIC DIAPHRAGM VALVES FOR LEAKS/WEAR

Instruction Code 1120‐S Date Last Edited 12/11/99

1120 WATER SOFTENER ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, AUTOMATIC REGENERATION

( ) CLEAN BRINE TANK AS REQUIRED‐PERFORM CORROSION

( ) CLEAN BRINE TANK AS REQUIRED‐PERFORM CORROSION

( ) CHECK, TIGHTEN ALL ELECTRICAL CONNECTIONS ON CONTROLLER

Instruction Code 1120‐W Date Last Edited 12/11/99

1120 WATER SOFTENER ‐ WEEKLY MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, AUTOMATIC REGENERATION

( ) WEEKLY ADD SALT TO BRINE TANK AS REQUIRED

June 11, 2009 [Type text] P a g e | 27

Instruction Code 1121‐A Date Last Edited 12/11/99

1121 WATER SOFTENER ‐ ANNUAL MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, MANUAL REGENERATION

( ) CLEAN BRINE TANK/PERFORM CORROSION CONTROL

Instruction Code 1121‐D Date Last Edited 12/11/99

1121 WATER SOFTENER ‐ DAILY MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, MANUAL REGENERATION

( ) CHECK OUTPUT WATER HARDNESS/PH (AS REQUIRED)

( ) ADD SALT TO BRINE TANK (AS REQUIRED

Instruction Code 1121‐M

1121 WATER SOFTENER ‐ MONTHLY MAINTENANCE

APPLIES TO: ION EXCHANGE RESIN BED, SALT REGENERATED, MANUAL REGENERATION

( ) CHECK UNIT FOR PROPER OPERATION

( ) CHECK CYCLE OPERATIONS (AS REQUIRED)

( ) CHEC SYSTEM FOR LEAKS

Instruction Code 1121‐Q Date Last Edited 02/17/00

1121 WATER SOFTNER ‐ QUARTERLY MAINTENANCE

( ) PERFORM IN ACCORDANCE W/MANUFACTURER INSTRUCTIONS

Instruction Code 1121‐S Date Last Edited 02/17/00

1121 WATER SOFTNER ‐ SEMIANNUAL MAINTENANCE

( ) PERFORM IN ACCORDANCE W/MANUFACTURER INSTRUCTIONS

Instruction Code 1131‐A Date Last Edited 02/17/00

1131 WATER DISTILLING UNIT ‐ ANNUAL MAINTENANCE

APPLIES TO: STEAM EVAPORATOR, WATER‐COOLED CONDENSER, STORAGE TANK AND TRANSFER PUMP

( ) PERFORM IN ACCORDANCE W/MANUFACTURER'S INSTRUCTIONS

Instruction Code 1131‐D Date Last Edited 12/11/99

1131 WATER DISTILLING UNIT ‐ DAILY MAINTENANCE

APPLIES TO: STEAM EVAPORATOR, WATER‐COOLED CONDENSER, STORAGE TANK AND TRANSFER PUMP

( ) CHECK UNIT FOR PROPER OPERATION, REPAIR AS NEEDED

June 11, 2009 [Type text] P a g e | 28

( ) CHECK WATER CONDUCTIVITY PH

( ) INSPECT FOR LEAKS

Instruction Code 1131‐M Date Last Edited 12/11/99

1131 WATER DISTILLING UNIT ‐ MONTHLY MAINTENANCE

APPLIES TO: STEAM EVAPORATOR, WATER‐COOLED CONDENSER, STORAGE TANK AND TRANSFER PUMP

( ) CHECK STEAM CONTROL VALVE

( ) CLEAN CONDENSATE TRAP/STRAINER

( ) CHECK CONDENSER WATER CONTROL VALVE

( ) CHECK SUPPLY WATER CONTROL VALVE

Instruction Code 1131‐Q Date Last Edited 02/18/00

1131 WATER DISTILLING UNIT ‐ QUARTERLY MAINTENANCE

APPLIES TO: STEAM EVAPORATOR, WATER‐COOLED CONDENSER, STORAGE TANK AND TRANSFER PUMP

( ) PERFORM IN ACCORDANCE W/MANUFACTURER'S INSTRUCTIONS

Instruction Code 1131‐S Date Last Edited 12/11/99

1131 WATER DISTILLING UNIT ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: STEAM EVAPORATOR, WATER‐COOLED CONDENSER, STORAGE TANK AND TRANSFER PUMP

( ) CHECK TANK FILTERS

( ) CLEAN EVAPORATOR TANK

Instruction Code 1132‐A Date Last Edited 12/11/99

1132 WATER DISTILLING UNIT ‐ ANNUAL MAINTENANCE

APPLIES TO: ELECTRIC, FAN‐COOLED CONDENSER, AUTOMATIC WITH STORAGE TANK

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) CHECK WIRING CONNECTIONS/INSULATION

Instruction Code 1132‐M Date Last Edited 12/11/99

1112 WATER DISTILLING UNIT ‐ MONTHLY MAINTENANCE

APPLIES TO: ELECTRIC, FAN‐COOLED CONDENSER, AUTOMATIC WITH STORAGE TANK

( ) CHECK UNIT FOR PROPER OPERATION

( ) CHECK UNIT FOR LEAKS

( ) CHECK SUPPLY WATER FILTER‐REPLACE AS REQUIRED

( ) CHECK FLOAT SWITCHES‐HOLDING TANK

( ) CHECK FLOAT SWITCHES‐EVAPORATOR

Instruction Code 1132‐Q Date Last Edited 12/11/99

June 11, 2009 [Type text] P a g e | 29

1132 WATER DISTILLING UNIT ‐ QUARTERLY MAINTENANCE

APPLIES TO: ELECTRIC, FAN‐COOLED CONDENSER, AUTOMATIC WITH STORAGE TANK

( ) CLEAN CONDENSER FAN/CONDENSER AS REQUIRED

( ) CLEAN EVAPORATOR‐CHECK HEATING ELEMENT

Instruction Code 1132‐S Date Last Edited 12/11/99

1132 WATER DISTILLING UNIT ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: ELECTRIC, FAN‐COOLED CONDENSER, AUTOMATIC WITH STORAGE TANK

( ) LUBE CONDENSER FAN MOTOR BEARINGS IF NEEDED

Instruction Code 1140‐M Date Last Edited 12/11/99

1140 WATER DEMINERALIZER ‐ MONTHLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL, EXHANGE TANK REGENERATION

( ) CHANGE DEIONIZER TANK AS REQUIRED

Instruction Code 1140‐S Date Last Edited 12/11/99

1140 WATER DEMINERALIZER ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL, EXHANGE TANK REGENERATION

( ) CLEAN UNIT CHECK CORROSION

Instruction Code 1140‐W Date Last Edited 12/11/99

1140 WATER DEMINERALIZER ‐ WEEKLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL, EXHANGE TANK REGENERATION

( ) CHECK UNIT OPERATION‐ADJUST AS NEEDED

( ) WEEKLY CHECK OUTPUT WATER CONDUCTIVITY/PH

Instruction Code 1141‐A Date Last Edited 12/11/99

1141 WATER DEMINERALIZER ‐ ANNUAL MAINTENANCE

APPLIES TO: RESIN BED TYPE, AUTOMATIC REGENERATION, ACID/CAUSTIC TANKS, CONTROL SYSTEM

( ) CHECK/CALIBRATE CONDUCTIVITY CELL/INSTRUMENT (REFER TO MANUAL)

( ) CHECK INSTRUMENT AIR (CONTROL/LINES) REPAIR IF NECESSARY

( ) CHANGE DESICCANT IN FILTER ON ACID TANK

( ) CLEAN ACID/CAUSTIC TANKS

( ) CHEC WIRING CONNECTION/INSULATION

( ) CHECK/CHANGE MEDIA IN CARBON TANK (REFER TO MANUAL)

June 11, 2009 [Type text] P a g e | 30

( ) CHECK ANIONRESINS FOR OVER RUN

Instruction Code 1141‐D Date Last Edited 12/21/99

1141 WATER DEMINERALIZER ‐ DAILY MAINTENANCE

APPLIES TO: RESIN BED TYPE, AUTOMATIC REGENERATION, ACID/CAUSTIC TANKS, CONTROL SYSTEM

( ) CHECK SYSTEM FOR LEAKS

( ) CHECK UNIT FOR PROPER OPERATION, ADJUST AS NEEDED

( ) BACKWASH CARBON PREFILTER TANK (30 MINUTE FLUSH)

( ) CHECK HEATERS IN CAUSTIC TANK ( REFER TO MANUAL)

( ) INSPECT FOR UNUSUAL VIBRATIOS/NOISES

( ) CHECK FOR RESIN LOSS

Instruction Code 1141‐M Date Last Edited 02/18/00

1141 WATER DEMINERALIZER ‐ MONTHLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, AUTOMATIC REGENERATION, ACID/CAUSTIC TANKS, CONTROL SYSTEM

( ) CHECK ACID/CAUSTIC LEVEL (BULK TANK)

Instruction Code 1141‐Q Date Last Edited 12/11/99

1141 WATER DEMINERALIZER ‐ QUARTERLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, AUTOMATIC REGENERATION, ACID/CAUSTIC TANKS, CONTROL SYSTEM

( ) CLEAN RESIN TRAPS

( ) CHECK ALL CONTROL VALVES FOR POSITIVE SHUT OFF

( ) CLEAN UNIT/PERFORM MINOR CORROSION CONTROL

Instruction Code 1141‐W Date Last Edited 12/21/99

1141 WATER DEMINERALIZER ‐ WEEKLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, AUTOMATIC REGENERATION, ACID/CAUSTIC TANKS, CONTROL SYSTEM

( ) REGENERATE DEMINERALIZER RESIN AS REQUIRED

( ) CHECK H2O HARDNESS BEFORE REGENERATION AS REQUIRED (SEE MANUAL)

Instruction Code 1142‐A Date Last Edited 12/11/99

1142 WATER DEMINERALIZER ‐ ANNUAL MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL REGENERFATION, ACID/CAUSTIC TANKS

( ) CHECK/CALIBRATE CONDUCTIVITY CELL INSTRUMENT

( ) CHECK INSTRUMENT AIR (CONTROL LINES)

( ) CHANGE DESICCANT IN FILTER/ACID TANK

( ) CHECK ACID/CAUSTIC TANK

( ) CHECK WIRING CONNECTIONS

June 11, 2009 [Type text] P a g e | 31

( ) CHECK/CHANGE MEDIA IN CARBON TANK (REFER TO MANUAL)

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

Instruction Code 1142‐Q Date Last Edited 12/11/99

1142 WATER DEMINERALIZER ‐ DAILY MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL REGENERFATION, ACID/CAUSTIC TANKS

( ) CHECK SYSTEM FOR LEAKS

( ) CHECK UNIT FOR PROPER OPERATION, REPAIR AS NEEDED

( ) BACKWASH CARBO PREFILTER TANK (30 MINUTES)

( ) CHECK LEVEL OF RESIN BED (REFER TO MANUAL)

( ) CHECK HEATERS IN CAUSTIC TANK (REFER TO MANUAL)

( ) INSPECT FOR UNUSUAL VIBRATIONS/NOISES

( ) CHECK FOR RESIN LOSS

Instruction Code 1142‐M Date Last Edited 12/11/99

1142 WATER DEMINERALIZER ‐ MONTHLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL REGENERFATION, ACID/CAUSTIC TANKS

( ) LUBE PUMP/MOTOR BEARINGS

( ) CHECK COUPLING WEAR/ALIGNMENT

( ) CHECK OIL LEVEL IN ACID/CAUSTIC PUMP

( ) CHECK ACID/CAUSTIC LEVEL (BULK TANK)

Instruction Code 1142‐Q Date Last Edited 12/11/99

1142 WATER DEMINERALIZER ‐ QUARTERLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL REGENERFATION, ACID/CAUSTIC TANKS

( ) TRANSFER RESIN TO MAINTENANCE TANK/WASH

( ) CLEAN RESIN TRAPS

( ) CHECK ALL CONTROL VALVES FOR POSITIVE SHUT OFF

( ) CLEAN UNIT/PERFORM MINOR CORROSION CONTROL

( ) LUBRICATE ALL CONTROL VALVES

Instruction Code 1142‐S Date Last Edited 12/11/99

1142 WATER DEMINERALIZER ‐ SEMI‐ANNUAL MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL REGENERFATION, ACID/CAUSTIC TANKS

( ) CHANGE OIL IN CAUSTIC/ACID PUMPS

Instruction Code 1142‐W Date Last Edited 12/11/99

1142 WATER DEMINERALIZER ‐ WEEKLY MAINTENANCE

APPLIES TO: RESIN BED TYPE, MANUAL REGENERFATION, ACID/CAUSTIC TANKS

June 11, 2009 [Type text] P a g e | 32

( ) REGENERATE DIMINERALIZER RESIN AS REQUIRED

( ) CHECK H2O HARDNESS BEFORE REGENERATION AS NEEDED (SEE MANUAL)

Instruction Code 1143‐A Date Last Edited 1/27/00

1143 REVERSE OSMOSIS ‐ ANNUAL MAINTENANCE

( ) PERFORM IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS

Instruction Code 1143‐M Date Last Edited 1/27/00

1143 REVERSE OSMOSIS ‐ MONTHLY MAINTENANCE

( ) PERFORM IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS

Instruction Code 1143‐Q Date Last Edited 1/27/00

1143 REVERSE OSMOSIS ‐ QUARTERLY MAINTENANCE

( ) PERFORM IN ACCORDANCE W/MANUFACTURER INSTRUCTIONS

Instruction Code 1143‐S Date Last Edited 1/27/00

1143 REVERSE OSMOSIS ‐ SEMIANNUAL MAINTENANCE

( ) PERFORM IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS

Instruction Code 1150‐A Date Last Edited 2/16/00

1150 AIR SEPARATOR ‐ ANNUAL MAINTENANCE

APPLIES TO: HYDRONIC SYSTEM

( ) AS PER MANUFACTURER SPECIFICATIONS

Instruction Code 1150‐M Date Last Edited 2/16/00

1150 AIR SEPARATOR ‐ MONTHLY MAS

APPLIES TO: HYDRONIC SYSTEM

( ) AS PER MANUFACTURER SPECIFICATIONS

Instruction Code 1150‐Q Date Last Edited 2/16/00

1150 AIR SEPARATOR ‐ QUARTERLY MAINTENANCE

APPLIES TO: HYDRONIC SYSTEM

( ) AS PER MANUFACTURER SPECIFICATIONS

Instruction Code 1150‐S Date Last Edited 2/16/00

1150 AIR SEPARATOR ‐ SEMIANNUAL MAINTENANCE

APPLIES TO: HYDRONIC SYSTEM

June 11, 2009 [Type text] P a g e | 33

( ) AS PER MANUFACTURER SPECIFICATIONS

Instruction Code 1151‐A Date Last Edited 2/16/00

1511 WATER FILTER ‐ ANNUAL MAINTENANCE

APPLIES TO: HYDRONIC AND CHILLED WATER SYSTEM

PERFORM CORROSION CONTROL

Instruction Code 1151‐M Date Last Edited 2/16/00

1151 FILTER ‐ MONTHLY MAS

( ) PERFORM IN ACCORDANCE W/MANUFACTURER INSTRUCTIONS

Instruction Code 1151‐Q Date Last Edited 12/11/99

1151 FILTER ‐ QUARTERLY MAINTENANCE

APPLIES TO: HYDRONIC AND CHILLED WATER SYSTEM

( ) INSPECT FOR LEAKS, FILTER LOADING/CORROSION

( ) CHECK CARTRIDGE, CHANGE AS REQUIRED

Instruction Code 1151‐S Date Last Edited 2/16/00

1151 WATER FILTER ‐ SEMIANNUAL MAS

( ) PERFORM IN ACCORDANCE W/MANUFACTURER INSTRUCTIONS

Instruction Code 1210‐A Date Last Edited 12/11/99

1210 AIR COMPRESSOR ‐ ANNUAL MAINTENANCE

APPLIES TO: 3 H.P. OR LESS, BELT DRIVE WITH RECEIVER

( ) CHECK WIRING CONNECTIONS/INSULATION

( ) PERFORM CORROSION CONTROL ON COMPLETE UNIT

( ) TEARDON, INSPECT/OVERHAUL…

This is the start of the file's text. The full file is on GovTribe.