This site information sheet and federal contract opportunity document outline requirements for preventative and emergency maintenance services for an uninterruptible power supply (UPS) system at Buckley Air Force Base in Colorado. The site information sheet provides details on the UPS modules, integral equipment, batteries, preventative maintenance schedule, and contact information. The related federal contract opportunity is a pre-solicitation notice for line items including UPS emergency maintenance, preventative maintenance for UPS, batteries, ancillary equipment and diagnostic services, as well as repair actions and overseas travel. Responses are due by April 2019 and the period of performance is from April 2019 through April 2024. The justification cited is that no other sources but the incumbent can satisfy the agency's requirements. The contracting agency is the Department of the Air Force Materiel Command Lifecycle Management Center at Hill Air Force Base.
Site Sheet
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AFSPC Uninterruptible Power Supply (UPS) Site Information Sheet
| 4 Jun 2018 |
| Buckley AFB, Colorado |
| Bldg. 433 |
1. POINTS OF CONTACT
| Primary: Mr. Jacob Livingston |
| Alternate: Mr. Duane Bartley |
| Additional: Mr. Patrick Holder |
| Utilities Plant Supervisor |
| Electrical Engineer |
| Facilities Superintendent |
| Jacob.livingston.2@us.af.mil |
| duane.bartley.1@us.af.mil |
| Patrick.holder.1@us.af.mil |
| (720) 847-5794 |
| (720) 847-9893 |
| (720) 847-9982 |
| DSN 847-9982 |
| 720) 847-9916 |
| DSN 847-9916 |
24-Hour Work Center: Power Plant Control Room, (720) 847-5794/5, DSN 847-5794/5
AFSPC POC: Mr. Aller Delarosa; aller.delarosa.1@us.af.mil; (719) 554-2906; DSN 692-2906
Security Management Office (SMO) Code: SSO BUCKLEY; willard.viar.ctr@us.af.mil; (720) 847-7350; DSN 847-7350
Installation/Restricted Area/Facility Access Requirements: Contact POC for instructions and necessary forms
2. ORGANIZATION, MISSION, & LOCATION
Command and Organization: AFSPC; 14 AF; 460 SW; 460 OG; 2 SWS
| UNCLASS Mission Supported by UPS: SBIRS Mission Control Station |
| UPS Room #: 2nd Fl, Power Plant |
| Street Address Where UPS is Located: 18220 E. Crested Butte Ave. |
| Battery Rm #: 1st Fl, Power Plant |
| Installation: Buckley AFB |
| State: CO |
| Zip: 80011 |
| DoDAAC: F03000 |
3. UPS MODULE
Configuration: N+1 Parallel Redundant with isolated A & B Bus
| Manufacturer: Liebert |
| Series: NXL 40 |
| Model: 40S400A0AAA32A |
| Date Manufactured: Apr 2011 |
| Date Installed: 6 Jun 2011 |
| Caps Date Code: 1012 |
| kVA: 400 |
| kW: 360 |
| Input/Output Voltage: 480 / 480 |
| System Load: 70/138 kVA |
Module Serial #:
Tag #:
1 (1A) D11C240014 1 (1A) 1552953 2 (1B) D11C240015 2 (1B) 1552954 3 (2A) D11D240002 3 (2A) 1552955 4 (2B) D11D240003 4 (2B) 1552956
4. INTEGRAL EQUIPMENT (i.e. Parallel Cabinet, Maintenance Bypass Cabinet, etc.)
| Manufacturer: |
| Type: |
| Serial #: |
| Tag #: |
| Liebert |
| Static Transfer Switch # 2 |
| D11D5J0014 |
| 1552957 |
| Liebert |
| Static Transfer Switch # 1 |
| D11D5J0012 |
| 1552958 |
| Square D |
| Battery Disconnect Switch (x 12) |
| No S/N |
| No Tag # |
| Remote Monitor Panel: Yes, Power Plant Control Rm. |
| Emergency Power Off: No |
| Spares Kit: Yes |
5. BATTERIES
Configuration: Racks, (4) tiers per rack; (3) parallel racks per module; (40) jars in series per rack, (480) total jars
| Manufacturer: Fiamm |
| Series: |
| Model: 12FLX540 |
| Watts/Cell: 570 |
| Date Code: 0217 |
| Date Installed: 31 Mar 17 |
| Warranty: 3 yrs. |
| Type (Flooded/Sealed): Sealed |
| # Volts per Cell/Jar: 2 / 12 |
| DC Float: 540 VDC |
| # Strings / Unit: 3 |
| # Jars / String: 40 |
| # Cells / Jar: 6 |
| # Jars / Unit: 120 |
| Total Jars / System: 480 |
| Battery Monitoring System: No |
| Spare Batteries: No |
6. PREVENTIVE MAINTENANCE
Modules, integral equipment, and sealed batteries are semi-annual (every 6 mos.); flooded batteries are quarterly (every 3 mos.)
7. ADDITIONAL DATA
Laptop Computer Permitted in UPS Room: Yes (Submit attached Laptop Authorization Letter, Wi-Fi deactivated)
Mobile Telephones Permitted in UPS Room: No (Not permitted in Restricted Area)
Telephone in UPS/Battery Rooms: No/No