Option Year 2.xls

XLS spreadsheet 48 KB Posted

Attached to
FA5004-09-R-C001 Federal contract opportunity
Solicitation number
FA5004-09-R-C001
Issued by
Department of the Air Force Pacific Air Forces

About this file

Bid Schedule Option Year 2

View the file

Other files for this federal contract opportunity

Other files attached to FA5004-09-R-C001, newest first.
File Type Posted
P0008 Amendment 7.pdf PDF
JA-7 - ARRA Addenda 1.pdf PDF
P00007 Amendment 6.pdf PDF
P00006 Amendment 5.doc DOC document
Notice of Posting Error.doc DOC document
Notice of Question Submittal Due Date.2.doc DOC document
Specifications —
Questions and Responses 004.doc DOC document
Amendment Document.doc DOC document
Questions and Responses 005.doc DOC document
Base Year.xls XLS spreadsheet
Option Year 1.xls XLS spreadsheet
Notice of Question Submittal Due Date.1.doc DOC document
Amendment 3.pdf PDF
Questions and Responses 003.doc DOC document
Notice of Question Submittal Due Date.doc DOC document
Specifications —
Questions and Responses 002.doc DOC document
Modification Document P0003.doc DOC document
Site Visit Attendance Sheet.pdf PDF
Amended Solicitation FA5004-09-R-C001-0001.doc DOC document
Attachment JA-2 Wage Determination 4 Mar 2009.doc DOC document
Option Year 1.xls XLS spreadsheet
Base Year.xls XLS spreadsheet
Attachment JA-2 Wage Determination.doc DOC document
Specifications —
Copy of AFForm66.xlsx XLSX spreadsheet
Option Year 2.xls XLS spreadsheet
JA-4 Financial Reference Sheet.doc DOC document
Solicitation 17 Feb 2009.doc DOC document
JA-3 Past Performance Questionaire.doc DOC document
JA5 Haz Mat Sheet.doc DOC document
MFH DBA.doc DOC document
Hazardous Material Identification data.docx DOCX document
Financial Reference Sheet.docx DOCX document
PWS revised 28 Mar 09.docx DOCX document
Past Performance Questionnaire.docx DOCX document
Reports - check list Sample 3.xls XLS spreadsheet
FA5004-09-R-C014.pdf PDF
Water Distribution Map 1.pdf PDF
Wage Determination 05-2017 REV 10 17 Mar 2009.doc DOC document
Sanitary Sewer Map 2.pdf PDF
Show all 42

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

ITEMS 2001 – BID SCHEDULE OPTION YEAR 2
Line ItemDescriptionUnitEst QtyBase Year
Unit PriceBase Year

Total Price

2001AARemove composition shingles and felts to deckSF96000
2001ABRemove standing seam metal roof fasteners. Includes removal of all clips and fasteners.SF7200
2001ACRemove roof paversSF60000
2001ADReinstall Roof paversSF10000
2001AERemove Lightguard insulationSF6000
2001AFRemove existing loose laid roof insulation, up to and including 4" average thicknessSF30000
2001AGRemove existing loose laid roof insulation, over 4" average thicknessSF9000
2001AHRemove existing adhered or mechanically attached roof insulation, up to and including 4" average thicknessSF30000
2001AIRemove existing adhered or mechanically attached roof insulation, over 4" average thicknessSF9000
2001AJRemove Built-Up Roof (BUR) to the existing roof deckSF12000
2001AKRemove BUR containing asbestos to the existing deck, quantity <5,000 SF - work to be performed IAW 29 CFR 1910 and other applicable regulationsSF7200
2001ALRemove asbestos containing BUR to the existing deck, quantity >5,000 SF - work to be performed IAW 29 CFR 1910 and other applicable regulationsSF24000
2001AMRemove roof drain with insulation containing asbestos - work to be performed IAW 29 CFR 1910 and other applicable regulationsEA12
2001ANRemove single-ply roof membrane, flashing, and sealantSF66000
2001AORemove asphalt-based mastic containing asbestos - work to be performed IAW 29 CFR 1910 and other applicable regulationsSF120
2001APRemove existing plywood deckSF12000
2001AQRemove curb, nailer, or parapetBF14400
2001ARDemo 2" x X" wood roof joist - flat deck only (<3% slope). Does not include mechanical or electric workBF6000
2001ASRemove existing metal flashing, drip edge and expansion joint, to include all associated clips and fastenersSF48000
2001ATRemove roof turbine ventEA36
2001AURemove existing roof vent (gable, soffit, and/or ridge)EA12
2001AVRemove roof mechanical vent, excludes electrical and duct work (size calculated by metal area)SF1800
2001AWRemove existing metal ladder. Includes patching and painting of holes to match facility.LF300
2001AXInstall IRMA roof insulated to R38, tapered insulation (1/4" per foot minimum), minimum 1" thickness, paver ballast onlySF24000
2001AYInstall exposed membrane roof on a wood or steel deck, insulated to R38, 1/4'' per foot taper, 1'' minimum thickness, UL Classification of ASF18000
2001AZInstall exposed membrane roof on a wood or steel deck, insulated to R38, flat stock, UL Classification of ASF26000
2001BAInstall exposed membrane roof on a concrete deck, insulated to R38, 1/4'' per foot taper, 1'' minimum thickness, UL Classification of ASF24000
2001BBInstall exposed membrane roof on a concrete deck, insulated to R38, flat stock, UL Classification of ASF30000
2001BCExtend membrane up (and over, if appropriate) wall, parapet or curbSF30000
2001BDInstall tapered insulation for IRMA roof, SBS, BUR roof, crickets, and/or saddlesSF120000
2001BEInstall remanufactured flashing for VTRsEA600
2001BFInstall manufacturer approved walk-padSF2400
2001BGInstall 4" roof drain. Includes bowl installation and components, patching, repairs and cleanupEA12
2001BHInstall drain extension 2" to 4"EA25
2001BIInstall 4" adjustable drain extensionEA10
2001BJFlash roof drainEA120
2001BKFlash scupperEA120
2001BLStrip in all EPDM to EPDM seams, Does not include removal/replacement of insulation or paversLF6000
2001BMInstall new SBS modified 4-ply BUR system, (1 base, 2-ply type IV glass ply sheets, SBS Modified mineral surfaced cap sheeting using ASTM D312 asphalt)SF6000
2001BNInstall insulation for BUR system, R38, flat stock, 1/4 " per foot taper. 1'' minimum thicknessSF4800
2001BOInstall 3/4" perlite thermal barrierSF6000
2001BPInstall 5/8" gypsheeting thermal barrierSF6000
2001BQInstall flashing for penetration less than 6" outside diameterEA240
2001BRPatch area of protected BUR with 2-ply and new 60lb flood coat. Does not include removal/replacement of insulation or paversSF2400
2001BSRepair exposed BUR roof with flood coat(reflash, patch cut, reseal seams, etc).SF600
2001BTRepair exposed BUR roof with emulsion (reflash, patch cut, reseal, etc).SF600
2001BURepair exposed BUR roof with silver coat (reflash, patch cut, reseal seams, etc,).SF600
2001BVRepair exposed BUR roof with cap sheet (reflash, patch cut, reseal seams, etc).SF600
2001BWInstall ice and water shieldSF96000
2001BXInstall shingles, fiberglass, Class A 240#/SquareSQ3000
2001BYInstall roof vent, in MFH (gable, soffit and/or ridge), <36" x 36"EA60
2001BZInstall Clip Rib or equivalent standing seam metal roof. This item does not apply to pre-engineered buildingsSF12000
2001CAInstall premanufactured flashing for shingle roofEA120
2001CBInstall premanufactured flashing for metal roofEA36
2001CCInstall curbing, nailer, joist or parapet, treated woodBF30000
2001CDInstall plywood decking, 1/2" OSBSF14400
2001CEInstall plywood decking, 5/8" OSBSF6000
2001CFInstall plywood decking, 3/4" OSBSF6000
2001CGInstall plywood sheathing, 1/2" AWPA C9 treated woodSF12000
2001CHInstall plywood sheathing, 5/8" AWPA C9 treated woodSF6000
2001CIInstall plywood sheathing, 3/4" AWPA C9 treated woodSF6000
2001CJInstall metal flashing, expansion joint, etc in accordance with MFG recommendations and procedures less than or equal to 20gaSF14000
2001CKInstall metal flashing, expansion joint, etc in accordance with MFG recommendations and procedures greater than or equal to 19gaSF4000
2001CLInstall galvanized sheet metal for miscellaneous applications to include rooftop mechanical vent, etc less than or equal to 20 gaSF500
2001CMInstall galvanized sheet metal for miscellaneous applications to include rooftop mechanical vent, etc greater than or equal to 19 gaSF100
2001CNInstall OSHA approved safety ladder with top rails and cage.LF120
2001COInstall overflow scupper. Includes flashing and patching if necessaryEA24
2001CPInstall seamless prefinished steel gutters & downspoutsLF650
2001CQInstall snow bars for sloped roof, includes flashingLF480
2001CRInstall NORCLAD type fascia (min 16" extension)SF12000
2001CSInstall caulking, silicon rubber, up to 1/2" jointLF2400
2001CTClean and remove debris and ensure flow in existing roof drainEA60
2001CUCut hole in steel or wood deck for vent, duct, or drain installationSF120
2001CVCut hole in concrete deck for vent, duct or drain installationSF120
2001CWCore drill concrete block wall for roof drain piping, Includes sleeve, patching, fire caulking and clean upEA10
2001CXInstall rubber expansion joint, up to 2" wide openingLF12000
2001CYInstall rubber expansion joint, up to 4" wide openingLF6000
2001CZInstall new roof turbine ventEA30
2001DAInstall roof warranty signEA60
2001DBInstall heat tape with braided wire on outside of pipe, maximum of 3 wats per foot, include termination kits(electrical connection done by others)LF1200
2001DCInstall laminated rim joist, FFP - 9.5" tall, 1" wide (only for total roof replacement)LF480
2001DDInstall laminated rim joist, FFP - 11.875" tall, 1" wide (only for total roof replacement)LF480
2001DEInstall insulation, FFP - un-faced fiberglass batt, high density, R-30, 8.25" thick, 16" or 24" wideSF4800
2001DFInstall vapor barrier, FFP - 8-mil polyethylene (only for total roof replacement)SF4800
2001DGInstall wood I-joists, FFP - 11.875" tall, 2.5" wide flange, and all associated bracing, straps, and fasteners (only for total roof replacement)LF2400
2001DHBurdened hourly labor rate FFP Burdened labor rate for the purpose of, but not limited to, snow removal and inclement weather tent condition/removalHours240
2001DIConstruction of inclement weather tent FFP Construction of inclement weather ten using reinforced polySF6120
2001DJOperation of inclement weather tent- FFP Operation of inclement weather tent to include heaters, fuesland all necessary materials to operate between the temperatures of -10 and 30 degrees FahrenheitDays12
2001DKInstall 1/2" dia X 12" lightning protection air terminals over 75' highEA50
2001DLInstall lightning protection cable, 375 lb per thousand ft over 75' highLF500
2001DMInstall 3/4" dia grounding rod 10' long and weld wire to rodEA5
2001DNInstall #2 grounding stranded copper wireLF100
2001DOInstall 15 # Roofing feltSF1000
2001DPInstall 30# Roofing feltSF2000
2001DQInstall up to 4" piping for roof drain,including hangers and accessoriesLF4
Line Item Total