Attachment_3_-_PCR_Appendices2.pdf

PDF 3 MB Posted

Attached to
Chapel Kitchen Renovation Federal contract opportunity
Solicitation number
FA489719BA009
Issued by
Department of the Air Force Air Combat Command

About this file

Part 2 of Attachment 3 PCR Appendices

View the file

Other files for this federal contract opportunity

Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix I – Appliance cut sheets frigidaire.com

Drop-In Cooktop FPEC3085K S 30" Electric24" Built-In

Signature Features

Dishwashers

FDB2410HI C�/�S�/�B

SpaceWise® Silverware Basket There’s a place for all of your silverware in our multicompartment, removable basket.

Quiet Dishwasher A quiet performance every time.

Tall-Tub Design Our large capacity, tall-tub dishwasher fits up to 12 place settings so you can wash more at once.

Stainless Steel Interior Premium stainless steel interior for maximum durability.

Product Dimensions Height (Adjustable) 32-1/2"�–�34-7/8"

Width 24"

Depth (Including Door) 23"

More Easy-To-Use Features

Multiple Cycle Options Features easy-to-use cleaning cycle options.

Delay Start Set your dishwasher to run on your schedule.

Ready-Select® Controls Easily select options with the touch of a button.

Energy Saver Plus Cycle Eco-friendly cycle uses less energy without compromising cleaning performance.

Energy Saver Dry Option No heat dry option.

Attractive Stainless Steel Exterior1

Low Rinse-Aid Indicator Light

Control Lock Option

5-Level Wash Design

UltraQuiet™ 3 Sound Reduction System

ENERGY STAR®

A.D.A. Compliant2

Available in:

��1�Select model only.

2 �� When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./ A.B.A. Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

White (S)

Stainless (C)

Black (B)

Specifications subject to change.

NOTE: For planning purposes only. Always consult local and national electric and plumbing codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.

B

A

D C

Meets requirements of ASSE 1006

Accessories information available on the web at frigidaire.com

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

FDB2410HI 03/14 © 2014 Electrolux Home Products, Inc.

Features

Control Design

Digital Display

Door Latch

Stay-Put Door Hinge Design

Low Rinse-Aid Indicator Light

Interior Design

Interior Color

Wash System

Wash Levels�/�Wash Speeds

Sound Package

Filter

Filter Trap

Soft Food Disposer dB Level

Drying System

Cycles

Number of Cycles

Heavy

Normal

Light

Delicate

Favorite

China�/�Crystal

Rinse Only

Energy Saver Plus

Upper Rack Wash Only

Cycle Indicator Light

Control Lock

Options

Heat�/�No Heat Dry

Hi-Temp Wash

NSF® Certified Sanitize Rinse

Delay Start

Rack System

Rack Design�/�Rack Coating

Upper Rack –

Stemware�/�Champagne Glass Holders

Fold-Down Tines

Cup Shelves

Lower Rack –

SpaceWise® Silverware Basket

Fold-Down Tines

Small Items Cover

Certifications

ENERGY STAR®

A.D.A. Compliant1

Specifications

Water Inlet Location

Water Usage (Gallons)

Water Pressure (PSI)

Integral Air Gap on Supply

Leveling Legs

Power Supply Connection Location

Voltage Rating

Connected Load (kW Rating) @ 120 Volts�2

Amps @ 120 Volts

Shipping Weight (Approx.)

Ready-Select®

Yes

Yes

Yes

Yes

Tall Tub

Stainless Steel

Direct

5�/�1

UltraQuiet™ 3

Stainless Steel

Removable

Yes

Static

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

1–24 Hour

Deluxe�/�Nylon TufRacks™

Yes

Yes

3-Piece Split

Yes

Yes

Left Bottom Front

5.4

20 – 120

Yes

Right Bottom Front

120V�/�60�Hz�/�15A

1.44

69 Lbs.

Dishwashers FDB2410HI C�/�S/�B 24" Built-In

Product Dimensions

A�-�Height (Adjustable)

B�-�Width

C�-�Depth (Including Door)

D�-�Depth (To Tub Flange)

Depth with Door Open 90°

32-1/2"�–�34-7/8"

24"

23"

20-1/2"

46"

Cutout Dimensions

Height (Min.)

Height (Max.)

Width (Max.)

Depth (Min.)

32-1/2" (A.D.A.1)

35"

24"

24"

���1 �When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./A.B.A. Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

1 � For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.

Meets requirements of

ASSE 1006

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

FDB2410HI 03/14 © 2014 Electrolux Home Products, Inc.

Dishwasher Specifications

• Product Shipping Weight (approx.) – 69 Lbs.

• Voltage Rating – 120V�/�60 Hz�/�15 Amps (maximum 20 Amps if connected with disposer)

• Connected Load (kW Rating) @ 120 Volts = 1.44�kW

(For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)

• Amps @ 120V = 10 Amps

• Always consult local and national electric & plumbing codes.

Meets requirements of ASSE 1006�—�integral air gap on supply.

• Dishwasher enclosure requires that adjacent cabinets be square and plumb. Unit must be fully enclosed on top, sides and back; and not support any part of enclosure.

• For A.D.A. installation, (32 1/2") beneath 34"- high countertop may be accomplished by adjusting toekick and leveling legs.

• When installing unit adjacent to wall, cabinet or other obstruction that extends beyond front edge of unit, allow 2" minimum clearance between opened door and obstruction.

• Do not install unit beneath cooktop, damage will occur.

• Make sure location has required drain, water and electrical outlets to make proper connections.

• Air gap required if drain is connected to waste tee or disposer lower than 18" above floor. If no air gap required, minimum 32"-high drain loop must be used. Total drain hose length must not exceed 10' to drain outlet.

• Electrical and water supplies should enter enclosure on floor, or through rear or cabinet side walls, as shown in designated shaded area. Hot water line may pass through same hole as electrical cable and drain hose; or through additional 1-1/2" dia. hole designated to accommodate line.

• Water connection located on left side of dishwasher. Install hot water inlet line using no less than 3/8" O.D. copper and extend forward at least 18" from rear wall with hand shut-off valve accessible beneath sink.

• Water Pressure – Hot water line to dishwasher must provide between 20 and 120 pounds per square inch (psi).

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

Dishwashers FDB2410HI C�/�S/�B 24" Built-In

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

INSTGDLNS_SSR FR 01/14 © 2014 Electrolux Home Products, Inc.

General Installation Guidelines with Side-by-Side Refrigerator

Top

Use these dimensions and clearance instructions for planning purposes onlycc .yy For detailed installationFF instructions, refer to installation guide, packed with product, or on the web at frigidaire.com.

Front

Top

Front

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

INSTGDLNS_TMR FR 01/14 © 2014 Electrolux Home Products, Inc.

Use these dimensions and clearance instructions for planning purposes onlycc .yy For detailed installationFF instructions, refer to installation guide, packed with product, or on the web at frigidaire.com.

Front

Top

Front

Top

General Installation Guidelines with Top Mount Refrigerator

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

INSTGDLNS_FDR FR 01/14 © 2014 Electrolux Home Products, Inc.

Top

Use these dimensions and clearance instructions for planning purposes onlycc .yy For detailed installationFF instructions, refer to installation guide, packed with product, or on the web at frigidaire.com.

Front

Top

Front with French Door Refrigerator

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

INSTGDLNS_ARAF FR 01/14 © 2014 Electrolux Home Products, Inc.

Use these dimensions and clearance instructions for planning purposes onlycc .yy For detailed installationFF instructions, refer to installation guide, packed with product, or on the web at frigidaire.com.

Front

Top

Front

Top with All Refrigerator or All Freezer

SIGNATURE FEATURES

Upgrade Your Kitchen with a Built-in Look Upgrade your kitchen and get the look of a built-in range, with the fit of a traditional freestanding range. The Frigidaire® front control freestanding range easily fits into a 30" cutout.

Continuous Corner-to-Corner Grates Continuous Grates make it easy to move heavy pots and pans across burners without lifting.

Quick Boil Get meals on the table faster with our 17,000 BTU burner

— water boils faster than the traditional setting.

Flexible Five Burner Cooktop Get ultimate cooking flexibility with a powerful gas cooktop that has five elements designed to handle all of your cooking needs.

FFGH3054US

frigidaire.com / frigidaire.ca

PRODUCT DIMENSIONS

Height (Max.) 36-5/8"

Width 29-7/8"

Depth (Incl. Handle) 29-3/16"�

MORE EASY-TO-USE FEATURES

Low Simmer Burner Perfect for cooking delicate foods and sauces.

One-Touch Self Clean Your oven cleans itself — so you don’t have to.

Self-clean options available in 2- and 3-hour cycles.

Store-More™ Storage Drawer With the Store-More™ Storage Drawer, you will have extra space to store your cookware.

CERTIFICATIONS

A.D.A.-�Compliant When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./A.B.A.

Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

BURNERS BTU

Right Front 17,000

Right Rear 5,000

Left Front 12,000

Left Rear 9,500

Center Extra Zone 9,500

AVAILABLE

COLORS

S Stainless

FREESTANDING

RANGE

30" GAS

Specifications subject to change. Accessories information available on the web at frigidaire.com / frigidaire.ca

Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca.

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

FFGH3054U 09/18

©�2018 Electrolux Home Products, Inc.

PRODUCT DIMENSIONS

A�-�Height (Max.) 36-5/8"

B�-�Width 29-7/8"

C�-�Depth (Incl. Handle) 29-3/16"

Depth with Door Open 90° 47"

CABINET CUTOUT DIMENSIONS

Height (Standard) 36"

Width (Min.) 30"

Depth (Min.) 24"

FEATURES

Oven Control�/�Timing System Ready-Select® Controls

Surface Type Black Porcelain

Sealed Gas Burners Yes

Grates Cast Iron with Black Matte Finish

Window Extra-Large

Exterior Door Finish Stainless

Handle Design Stainless

Exterior Finish (Side Panels) Black

Oven Cleaning System Self Clean

Drawer Functionality Storage

OVEN CONTROLS

Bake Yes

Broil Yes

Delay Start Yes

Delay Bake Yes

Self-Clean 2, 3 Hour

Delay Clean Yes

Kitchen Timer Yes

Timed Cook Option Yes

Auto Oven Shut-Off 12 Hours

Oven Lock-Out Yes

COOKTOP FEATURES

Right Front Burner (BTU) 17,000

Right Rear Burner (BTU) 5,000

Left Front Burner (BTU) 12,000

Left Rear Burner (BTU) 9,500

Center Extra Zone Burner (BTU) 9,500

OVEN FEATURES

Capacity (Cu.�Ft.) 5.0

Oven Light 1 Incandescent 40W

Rack Configuration 2 Standard

Baking System Even Baking Technology

Broiling System Vari-Broil™ (Hi�/�Lo)

Bake Burner�/�Broil Burner (BTU) 18,000�/�13,500

OPTIONAL ACCESSORIES

LP Gas Conversion Kit PN�# GRLP4

CERTIFICATIONS

A.D.A. Compliant1 Yes

SPECIFICATIONS

Oven Interior (�H x W x D�) 18-5/8"�x�24-3/8"�x�19-1/8"

Power Cord Connection Location Middle Bottom Rear

Gas Supply Connection Location Right Bottom Rear

Voltage Rating 120V�/�60�Hz�/�5A

Amps @ 120 Volts 5.0

Shipping Weight (Approx.) 190 Lbs.

1� When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./A.B.A. Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

A

C

B

FFGH3054US

FREESTANDING RANGE

INSTALLATION SPECIFICATIONS

• Product Shipping Weight (approx.) – 190 Lbs.

• Voltage Rating – 120V�/�60 Hz�/�5 Amps

• Amps @ 120 Volts = 5.0 Amps

• Always consult local and national electric and gas codes.

• Make sure wall coverings around range can withstand heat generated by range.

• Linoleum or any other synthetic floor covering located beneath range, must be capable of withstanding minimum heat of 90° F above room temperature without shrinking, warping or discoloring. Insulating pad or 1/4"-thick plywood required between range and a carpeted floor.

• Do not obstruct flow of combustion air at oven vent nor around base or beneath lower front panel of range. Range requires fresh air for proper burner combustion.

• Do not install range beneath any downward-blowing, overhead vent hood or air curtain.

• Range ships with 3/4" factory regulator.

• Range is LP Gas convertible. (Optional LP Gas Conversion Kit available.)

• Floor beneath range MUST be solid and level.

• Overhead cabinetry should not exceed a 13" maximum depth.

• Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance.

• Range can be installed flush to wall with 0" minimum rear clearance.

• Minimum clearance required (from edge of rangetop to nearest combustible wall on either side of range above 36" height) is based on largest burner output rating on cooking surface.

• Allow 30" minimum clearance between top of cooking surface and bottom of unprotected wood or metal overhead cabinet; or 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/4" flame-retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.

• To reduce risk of fire when using overhead cabinetry, install range hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets.

• Follow all dimension requirements provided to prevent property damage, potential fire hazard, and incorrect countertop and cabinet cuts.

OPTIONAL ACCESSORIES

• LP Gas Conversion Kit – (PN�# GRLP4).

Specifications subject to change. Accessories information available on the web at frigidaire.com / frigidaire.ca

Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca.

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

FFGH3054U 09/18

©�2018 Electrolux Home Products, Inc.

29 3/16"

47 "

*Note: 30" minimum clearance between top of cooking surface and bottom of unprotected wood or metal overhead cabinet; or 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/4" flame-retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.

0" clearance is minimum for rear of range. Follow all dimension requirements provided above to prevent property damage, potential fire hazard, and incorrect countertop and cabinet cuts.

121/16"

30" min.

13" max.

25" max.

Minimum 5" clearance required to nearest combustible wall on either side of range above 36" height

CL

36" stand.

30" min.*

Recommended area for 120V outlet on rear of wall

18" min.

8"

61/2"

18" min.

22 5/8"

Wall

4"4"

4 5/16"

Front

Gas inlet location (right bottom rear*) Power cord location

(middle bottom rear*) *when viewed from front

29 7/8"

365/8" (Adjustable to ±1/4" max.)

Side

30" min.

Area MUST remain clear

26 3/4"

121/16"

Recommended area for through-the-wall or through-the-floor connection of pipe stub and shutoff valve

FFGH3054US

FREESTANDING RANGE

Ready-Select® Controls Easily select options or control cooking temperature with our easy-to-use controls.

Oven Rack Handles Oven racks are designed with space for you to easily pull out the racks, even when wearing an oven mitt.

Even Baking Technology Our Even Baking Technology ensures even baking every time.

FFEW2726T S�/�W�/�B

frigidaire.com

PRODUCT DIMENSIONS

Height 29"

Width 27"

Depth 24-3/4"

MORE EASY-TO-USE FEATURES

Attractive Stainless Steel Exterior1

Self-Cleaning Your oven cleans itself — so you don't have

to. Self clean options available in 2-, 3- and 4-hour cycles.

CERTIFICATIONS

A.D.A.�-�Compliant When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./A.B.A.

Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

Star-K® Certified (Sabbath Mode)

1 Select models only.

SINGLE WALL OVEN

27" ELECTRIC

AVAILABLE

COLORS

S Stainless

W White

B Black

FFEW2726T 07/17

©�2017 Electrolux Home Products, Inc.

Specifications subject to change. Accessories information available on the web at frigidaire.com

Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.

E

D

B

A

Spacer

C

PRODUCT DIMENSIONS

A�-�Height 29"

B�-�Width 27"

C�-�Depth 24-3/4"

D�-�Height (Wrapper) 27-1/4"

E�-�Width (Wrapper) 24-5/8"

Depth with Door Open 90° 44-3/4"

CUTOUT DIMENSIONS

Height (Min.) 27-1/4"

Height (Max.) 28-1/4"

Width (Min.) 24-7/8"

Width (Max.) 25-1/4"

Depth (Min.) 24"

FEATURES

Oven Control�/�Timing System Ready-Select®

Window Large

Exterior Door Finish Stainless Steel (S), Color-Coordinated (W/B)

Handle Design Stainless Steel (S), Color-Coordinated (W/B)

Oven Cleaning System Self-Clean

OVEN CONTROLS

Bake�/�Broil Yes�/�Variable (400 - 550°F)

Convection Conversion

Convection Bake�/�Broil�/�Roast

Quick Bake Convection

Quick Preheat

My Favorite

Slow Cook

Effortless™ Temperature Probe

Keep Warm Yes

Add-a-Minute

Delay Start Yes

Self-Clean�/�Clean Options Yes�/�2, 3, 4 Hours

Steam Clean

Delay Clean Yes

Kitchen Timer Yes

Timed Cook Option Yes

Control Lock Yes

Auto Oven Shut-Off

Oven Lock-Out Yes

OVEN FEATURES

Capacity (Cu.�Ft.) 3.8

Convection System

Oven Light 1 Halogen

Hidden Bake Element Yes

Rack Configuration 2 Handle Racks

Baking System Even Baking Technology

Broiling System Vari-Broil™

Bake�/�Broil Element (Watts) 1,450�/�3,400

OPTIONAL ACCESSORIES

3"-High Bottom Trim�–� Stainless Steel (S)�/�White (W)�/ Black (B)

(S) PN�# 318903509

(W) PN�# 318903506

(B) PN�# 318903507

10'-Long Armored Power Cable PN�# 903056-9010

CERTIFICATIONS

A.D.A. Compliant1 Yes

Sabbath Mode (Star-K® Certified) Yes

SPECIFICATIONS

Oven Interior (�H x W x D�) 17"�x�20-1/2"�x�18-3/4"

Power Supply Connection Location Left Bottom Rear

Voltage Rating 240V�/�208V�/�60Hz

Connected Load (kW Rating) @ 240�/�208 Volts2 3.7�/2.8

Amps @ 240�/�208 Volts 15.4�/�13.5

Minimum Circuit Required (Amps) 20

Approved for Under-Counter Installation Yes

Shipping Weight (Approx.) 130 Lbs.

1 When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./A.B.A. Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

2 Single phase 3- or 4-wire cable, 120�/�240 or 120�/�208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line.

FFEW2726T S�/�W�/�B

SINGLE WALL OVEN

27" ELECTRIC

FFEW2726T 07/17

©�2017 Electrolux Home Products, Inc.

INSTALLATION SPECIFICATIONS

• Product Shipping Weight (approx.) – 130 Lbs.

• Single phase 3- or 4-wire cable, 120�/�240 or 120�/�208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line.

• Connected Load (kW Rating) @ 240�/�208 Volts = 3.7�/�2.8�kW

• Amps @ 240�/�208 Volts = 15.4�/�13.5 Amps

• Recommended Circuit Breaker – 20 Amps

• Always consult local and national electric codes.

• Minimum 21" clearance for oven door depth when open.

• Suggested distance from floor is 31". Minimum required distance is 4-1/2".

• Minimum 24" deep cutout dimension is critical for proper installation, to ensure that oven’s faceplate will fit flush against cabinet front.

• For cutout height greater than 28-1/4”, add one 2”-wide wood shim of appropriate height to each side of opening under oven side rails. Optional 3”-high bottom trim available to hide larger cutout height.

• Full oven base of solid plywood or similar material required, capable of supporting 150 Lbs.

• Base must be level and cabinet front must be square.

• Single Wall Oven is NOT approved to be used in stackable or side-by-side installation.

• Single Wall Oven is approved to be used alone in under-counter installation or beneath any approved Frigidaire® gas or electric cooktop. (Refer to Gas or Electric Cooktop Installation Over 30"�/�27" Electric Single Wall Oven Specifications pages on web.)

• Single Wall Oven is approved to be used in combination with any Frigidaire® Warmer Drawer. (Refer to model-specific Warmer Drawer product page for Combination Installation Specifications.)

• Single Wall Oven is approved to be used in combination with any Frigidaire® Built-In Microwave Oven.

OPTIONAL ACCESSORIES

• 3"-High Stainless Steel Bottom Trim – (PN�# 318903509).

• 3"-High White Bottom Trim – (PN�# 318903506).

• 3"-High Black Bottom Trim – (PN�# 318903507).

• 10'-Long Armored Power Cable – (PN�# 903056-9010).

Specifications subject to change. Accessories information available on the web at frigidaire.com

Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.

*Critical dimension – MUST be applied **For cutout height greater than 28 1/4", add one 2"-wide wood shim of appropriate height to each side of opening under oven side rails. Optional 3"-high bottom trim available to hide larger cutout height.

3"

24 5/8"

29" (includes 1" bottom trim) Spacer

27"

Allow at least 21" clearance for door depth when open

Power supply location (left bottom rear)

Electrical junction box location

2" min.

1 1/2" min.

Full base required to support 150 lbs.

4" x 4" opening to route armored cable

24" min.* (critical dimension) 2"-wide wood spacers (if needed)**

31" suggested distance

41/2" min.

required

27 1/8" min.

24 7/8" min.

25 1/4" max.

24 3/4"

27 1/4"

27 1/4" min.

28 1/4" max.

FFEW2726T S�/�W�/�B

SINGLE WALL OVEN

27" ELECTRIC

Full-Width Wire Freezer Shelf Gives you a way to organize items in your freezer better so you can find food quickly.

Reversible Door Door can be installed to open left or right based on your needs.

Store-More™ Gallon Door Shelf Door storage gives you room for larger items like a gallon of milk.

Store-More™ Humidity-Controlled Crisper Drawers Keep your fruits and vegetables fresh in our humidity-controlled crisper drawers.

FFHT1821T S/W/B

frigidaire.com / frigidaire.ca

AVAILABLE

COLORS

S Stainless

W White

B Black

PRODUCT DIMENSIONS

Height (Including Hinges & Rollers) 66-1/8"

Width 30"

Depth (Including Door) 30-1/8"

MORE EASY-TO-USE FEATURES

Clear Dairy Bin Keep foods like butter, cheese and yogurt organized.

CERTIFICATIONS

A.D.A.-�Compliant1

With accessible shelving, and controls that are positioned within arm’s reach and allow one-hand operation, our top-freezer refrigerator is A.D.A.-�Compliant.

ENERGY STAR®

1� When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./A.B.A. Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

TOP MOUNT

REFRIGERATOR

18.0 CU. FT. TOP MOUNT

Specifications subject to change. Accessories information available on the web at frigidaire.com / frigidaire.ca

Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca.

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

FFHT1821T 10/17

©�2017 Electrolux Home Products, Inc.

B

A

C

FEATURES

Door Design UltraSoft™

Door Handle Design Stainless Steel (S), Color-Coordinated (W/B)

Cabinet Finish (Textured) Black (S), Color-Coordinated (W/B)

Door Stops Yes

Door Hinge Covers Black (S), Color-Coordinated (W/B)

Door Reverse Option Yes

Rollers – Front�/�Rear Fixed�/�Yes

Sound Package

Toe Grille Black (S), Color-Coordinated (W/B)

REFRIGERATOR FEATURES

Interior Lighting Standard

Refrigerator Shelves 2 Full-Width Glass

Deli Drawer 1 Half-Width

Wine�/�Can Rack

Store-More™ Crisper Drawers 2 Clear

Humidity Controls 2

Dairy Compartment Clear Dairy Door

Door Bins

Door Racks 3 Full-Width White

Non-Slip Bin Liner

Tall Bottle Retainers

Gallon Door Storage 1

FREEZER FEATURES

Door Bins

Door Racks 2 Full-Width White

Freezer Shelves 1 Full-Width Wire

Factory Ice Maker w/ Large Ice Bin Optional (PN�# IM116)

Lighting

CERTIFICATIONS

A.D.A. Compliant1 Yes

ENERGY STAR® Yes

SPECIFICATIONS

Total Capacity (Cu. Ft.) 18.0

Refrigerator Capacity (Cu. Ft.) 14.1

Freezer Capacity (Cu. Ft.) 3.9

Power Supply Connection Location Right Bottom Rear

Water Inlet Connection Location Bottom Right

Voltage Rating 120V�/�60Hz

Connected Load (kW Rating) @ 120 Volts2 0.72

Amps @ 120 Volts 6.0

Minimum Circuit Required (Amps) 15

Shipping Weight (Approx.) 205 Lbs.

1 When properly installed, this model is A.D.A.-qualified based on the United States Access Board’s A.D.A./A.B.A. Accessibility Guidelines and the Department of Justice’s 2010 A.D.A. Standards for Accessible Design.

2 For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.

PRODUCT DIMENSIONS

A�-�Height (Including Hinges & Rollers) 66-1/8"

B�-�Width 30"

C�-�Depth (Including Door) 30-1/8"

Depth with Door Open 90° 58-1/2"

FFHT1821T S/W/B

TOP MOUNT REFRIGERATOR

18.0 CU. FT.

INSTALLATION SPECIFICATIONS

• Product Shipping Weight (approx.) – 205 Lbs.

• An electrical supply with grounded three-prong receptacle is required. The power supply circuit must be installed in accordance with current edition of National Electrical Code (NFPA 70) and local codes & ordinances.

• Voltage Rating – 120V�/�60 Hz

• Connected Load (kW Rating) @ 120 Volts = 0.72�kW

• Amps @ 120 Volts = 6.0 Amps

• Always consult local and national electric & plumbing codes.

• Floor should be level surface of hard material, capable of supporting fully loaded refrigerator.

• Minimum 3/8" clearance required for sides and top of refrigerator with

1" clearance at rear to allow for ease of installation, proper air circulation, and plumbing�/�electrical connections.

• When installing refrigerator adjacent to wall, cabinet or other appliance that extends beyond front edge of unit, 20" minimum clearance recommended to allow for optimum 140°�door swing, providing complete crisper access and removal. (Absolute 3" minimum clearance will ONLY allow for 90° door swing which will provide limited crisper access with restricted removal.)

• To ensure optimum performance, do not install in areas where temperature drops below 55°�F or rises above 110°�F and avoid installing in direct sunlight or close proximity to range, dishwasher or other heat source.

• For proper ventilation, front grille MUST remain unobstructed.

• Recess electrical outlet when possible.

• Optional Ice Maker Kit (PN�# IM116) available for installation in ice maker-ready models only.

• Water recess on rear wall recommended to prevent water line damage.

• Water Pressure – Cold water line must provide between 30 and 100 pounds per square inch (psi).

• Copper tubing with 1/4" O.D. recommended for water supply line with length equal to distance from rear of unit to household water supply line plus 7 additional feet. Optional Water Supply Installation Kits available.

OPTIONAL ACCESSORIES

• Ice Maker Kit – (PN�# IM116).

Specifications subject to change. Accessories information available on the web at frigidaire.com / frigidaire.ca

Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com / frigidaire.ca.

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

FFHT1821T 10/17

©�2017 Electrolux Home Products, Inc.

Top View

Allow 1" min. clearance at rear for proper air circulation and water / electrical connections

Allow 3/8" min. clearance at sides and top for ease of installation

Recessed water line (ice maker models only)

Recessed electrical outlet

* When installing refrigerator adjacent to wall, cabinet or other appliance that extends beyond front edge of unit, 20" minimum clearance recommended to allow for optimum 140° door swing, providing complete crisper access and removal. (Absolute 3" minimum clearance will ONLY allow for 90° door swing which will provide limited crisper access with restricted removal.)

When installing directly adjacent to wall, sufficient handle clearance required where handle may make contact with wall, to allow for 90° door opening*

29 5/8"

Power cord location (right bottom rear)

Water line inlet location (left bottom rear)

Allow 58 1/2" min.

(with doors 90° open)

30 1/8"

26 5/8"

32 1/8"

66 1/8" with 3/8" rollers

65 3/8" with 3/8" rollers

FFHT1821T S/W/B

TOP MOUNT REFRIGERATOR

18.0 CU. FT.

frigidaire.com

Signature Features

Countertop

Product Dimensions Height 13-7/8"

Width 24"

Depth 21-3/8"

More Easy-To-Use Features

Ready-Select® Controls Easily select options with the touch of a button.

Auto One-Touch Options Our microwaves feature easy-to-use one-touch buttons so you can cook beverages, baked potatoes, popcorn, fresh veggies or even add thirty seconds with the touch of a button.

Effortless™ Defrost Makes it easy to defrost almost anything, quickly and evenly.

Effortless™ Reheat Reheat almost anything at the touch of a button.

Multi-Stage Cooking Our Multi-Stage Cooking option allows you to program power levels and cooking times in advance, so you can program it to defrost, cook and keep a meal warm all at once.

10 Cooking Power Levels Provides the versatility needed to prepare everything from frozen pizza to pot roast quickly and easily.

Control Lock Option

Electronic Clock�/�Timer Helps you keep track of cook times.

Attractive Stainless Steel Exterior

Interior Light Illuminates the contents of the microwave for increased visibility.

Large Glass Turntable Even large items fit on our large glass turntable.

Available in:

Stainless (S)

Microwave

FFCE2278LS

Melt & Soften Use the microwave to quickly melt or soften butter or cheeses for your recipes.

Easy-Set™ Start Quickly start cooking�–�one to six minutes�–�with just one touch.

One-Touch Keep Warm Setting Keep food warm until everything�—� and everyone�—�is ready.

Sensor One-Touch Options Microwave automatically adjusts power levels and cooking times to cook a variety of items, effortlessly.

Accessories information available on the web at frigidaire.com

Accessories information available on the web at frigidaire.com

Features

Control�/�Timing System

Exterior Door Finish

Handle Design

Microwave Features

Microwave Capacity (Cu.�Ft.)

Watts (IEC-705 Test Procedure)

Interior Light

Interior Color

Turntable Diameter

Turntable On�/�Off

Control Lock

Clock

Touch Pad Buttons

Power Levels

Accessory Metal Rack

Microwave Control Options

Easy-Set™ Start

Popcorn Button

Chicken Nugget Button

Baked Potato Button

Sensor Reheat Button

Snack Button

Beverage

Melt & Soften Options

Auto Reheat Options

Snack Menu Options

Auto Cook Options

Auto Defrost Options

Keep Warm

Add-30-Seconds

Sensor Cooking Options

Vegetable Cook Sensor

Delay Start

User Preferences

Power Ratings

Frequency (Mhz)

Watts @ 120 Volts

Amps @ 120 Volts

Specifications

Oven Interior Height

Oven Interior Width

Oven Interior Depth

Power Supply Connection Location

Voltage Rating

Minimum Circuit Required (Amps)

Shipping Weight (Approx.)

CB

A

Ready-Select®

Stainless Steel

Push Button

2.2

1,200

Yes

White

16"

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

4�/�4

Yes

Yes

Yes

Yes

2,450

1,200

11-1/2"

17-1/16"

18-15/16"

Rear

120V�/�60Hz�/�15A

49 Lbs.

Product Dimensions1

A�-�Height

B�-�Width

C�-�Depth

13-7/8"

24"

21-3/8"

NOTE: For planning purposes only. Always consult local and national electric codes. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.

1 A minimum clearance of 3 inches is required above microwave oven and between microwave oven and adjacent walls.

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca

FFCE2278L 06/15 © 2015 Electrolux Home Products, Inc..

Microwave FFCE2278LS Countertop

Appendix L - Fire rated wall cut sheets

FIRE DOORS

INDUSTRY LEADING

COMMERCIAL & INDUSTRIAL SOLUTIONS

FIRE-RATED COUNTER DOORS

640/641

• Built-in safety

— Fusible links separate at 165°F (74°C) for ambient conditions under 100°F (38°C), or at 212°F (100°C) for ambient conditions over 100°F (38°C), to close the door automatically under governor control

— Meets strict fire safety testing standards

• Options for added safety and simplified operation

— Choice of a crank or electric operator

— A variety of smoke detectors

— UL-listed FireLite® vision lites

COMMON APPLICATIONS INCLUDE FACTORIES, SCHOOLS, CONCESSIONS,

HOSPITALS, CAFETERIAS AND RETAIL SETTINGS

• Fire Sentinel® for fail-safe protection

— UL-listed, fail-safe device provides a 10-second time-delay release and an independent 10-second time delay on power loss

• Choice of galvanized or stainless steel

• Fire-rated countertop for integrated design

— 1 1/2-hour rated countertop features a fire-resistant core and is available in a variety of decorative laminate finishes

MODELS 640/641 FIRE-RATED COUNTER DOORS

2501 S. State Hwy. 121 Bus., Suite 200, Lewisville, TX 75067 1-800-929-DOOR • sales@overheaddoor.com www.overheaddoor.com

©2018 Overhead Door Corporation. Overhead Door is a trademark and the Red Ribbon logo and Fire Sentinel are registered trademark of Overhead Door Corporation. All other trademarks are property of their rightful owners. Consistent with our policy of continuing product improvement, we reserve the right to change product specifications without notice or obligation. C900-190 01/18

INDUSTRY LEADING

COMMERCIAL & INDUSTRIAL SOLUTIONS

PowderGuard® Premium powder coat paint finish is available in approximately 200 colors, or may be color matched to architect’s specifications to best complement the look of the facility.

Color options

Gray TanWhite Brown

Standard features at a glance

• Available with UL and FM 3-hour (optional) Class A labels for masonry fire walls

• Available with a UL 1 1/2-hour Class B label for applications in non-masonry fire walls of dry wall with wood, steel studs, or steel tube jambs

• NFPA-80 compliant

• Fusible link separates at 165°F (74°C) to automatically close the door

• Governor controls rate of door descent during a fire

• Compact box guide design for an attractive appearance

• Upward-expanding guide design for flush to countertop installation

• Flat slat curtain design in primed galvanized steel finish (640 Model) or No. 4 stainless steel finish (641 Model)

• Slide bolt locking on push-up/crank

Options

• Flame baffle system (required for optional FM label)

• Fire Sentinel® time-delay release device

• FireLite® vision lites in 3- and 1 1/2-hour curtains

• Firestop® fire-resistant core countertops surfaced with the most popular brands of decorative laminates

• UL-listed brush-type smoke seals

• Photoelectric or ionization-type smoke detectors

• Crank or electric operation

• Electric operation does not require tension reset after drop test or closure due to power loss

• 20 minute UL smoke label on 640/641 doors up to 12'0" wide x 10'0" high opening

Model Slat Opening Width Standard

640 F-158 Thru 14'0" (4267 mm) 22 gauge

641 F-158 Thru 14'0" (4267 mm) 22 gauge stainless steel Slats are galvanized and painted or stainless steel.

1 1/2"

1/2"

F-158 Slat

Slat data

Actual door colors may vary from brochure photos due to fluctuations in the printing process. Always request a color sample from your Overhead Door™ Distributor for accurate color matching.

SUBMITTAL: FD2CI™ SERIES 2-4 HOUR FIRE-RATED UPWARD-OPENING ACCESS PANELS FOR CEILINGS PAGE 1 OF 2

Materials: Satin finish galvannealed steel or 304 stainless steel Frame: 16 gauge steel, 3 1/2” (89 mm), Depth “D”= 3-1/2” (89 mm).

Wall Trim: 7/8” (22 mm) Door Panel: 18 gauge with 22 gauge liner and interior lifting handle.

Insulation: The door panel contains 1 1/2” (38 mm) of high temperature insulation material.

Fuel Contribution: 0 Smoke Developed: 0 Flame Spread: 0 Finishes: Rust-inhibitive off-white prime coat or # 4 polished stainless steel finish on exterior surface.

Hinges: Concealed continuous piano hinge allows the door panel to open into a vertical position. The hinge is placed on the “H” dimension.

Panel Closer: The design of the unit allows the door panel to be self-closing.

Latch(es): The standard factory installed latch is a flush mount 1/4” allen key (A). The interior latch release is standard on doors including and exceeding 16”x 16”. Under 16”x 16” by request only.

Sizes: Common sizes are listed on page 2, however, other sizes are available upon request. Minimum size 12” x 12” Model FD3CI with a 3 Hour Rating has Now Been Incorporated into this Model with the new Higher Rating.

Two to Four hour fire-rated access panel for use in a ceiling application where control of temperature rise and heat trans-mission is required. Designed without the use of springs, allowing easier access through the door opening.

STEP 1: SELECT MODEL NUMBER AND QUANTITY ON CHART PAGE 2

Rough Opening is order size Other Size: ___ Inches Wide x ___ Inches High

STEP 2: SELECT FINISH

___ Steel with off-white primer ___ Stainless steel with #4 finish on exterior

OPTIONAL FEATURES AT ADDITIONAL COST

Latches: ____ (KK) Raised Knurled Knob Lock: ____ 11/8” mortise prep complete with mortise cylinder (MPI) ____11/8” mortise prep only (MP)

LATCH AND LOCK OPTIONS

Standard

1/4” Allen Key Optional

Knurled Knob

(KK)

Optional Mor-tise Lock (MPI)

This model of wall and ceiling fire-rated panels is manufactured under the factory inspection service of Intertek Warnock Hersey™ and have a label reading: “Listed access door and frame assembly (insulated). Horizontal Installation only. Fire Rating: 2 Hours Combustible Con-struction, 4 Hours Non-Combustible Construc-tion. File # 22601.

Testing Standards:

Horizontal: UBC-43-7-91, CAN/ULC-S112 Warning: Not for installation in floors: Does not meet NFPA 288. This door does not support a live load.

Distributor: Quantity:

Contractor: Approved By:

Model #: Architect:

*DOWNLOAD CURRENT SUBMITTAL BEFORE ORDERING*

©2017 ACTIVAR CONSTRUCTION PRODUCTS GROUP, INC.— FD2CI™ IS A TRADEMARK OF ACTIVAR Project: Date:

HEADQUARTERS:9702 NEWTON AVE S, BLOOMINGTON, MN 55431 PH: 800-554-6077 FAX: 952-835-2218 EMAIL: SALES@ACTIVARCPG.COM WWW.ACTIVARCPG.COM MANUFACTURING: BLOOMINGTON, MN & COMMERCE, CA WAREHOUSES: FORT MYERS FL, DALLAS TX, LANCASTER PA, ATLANTA GA, CHICAGO, IL, SEATTLE WA, OMAHA NE, FARGO ND 5/3/17

Rough Opening is Order Size W x H (hinge side) ҂

Door Size No. of

Latches/ Locks

Weight in Lbs.

QTY Model Size W X H (inches)

Metric (mm) Model

12 x 12 305 x 305 11-5/8 x 11-5/8 1 11.50 FD2CI-1212 14 x 14 356 x 356 13-5/8 x 13-5/8 1 14.50 FD2CI-1414 16 x 16 406 x 406 15-5/8 x 15-5/8 1 17.00 FD2CI-1616 18 x 18 457 x 457 17-5/8 x 17-5/8 1 21.00 FD2CI-1818 18 x 24 457 x 610 17-5/8 x 23-5/8 1 26.50 FD2CI-1824 18 x 30 457 x 762 17-5/8 x 29-5/ 1 31.00 FD2CI-1830 18 x 36 457 x 914 17-5/8 x 35-5/8 1 37.25 FD2CI-1836 18 x 48 457 x 1219 17-5/8 x 47-5/8 1 49.00 FD2CI-1848 20 x 20 508 x 508 19-5/8 x 19-5/8 1 24.50 FD2CI-2020 20 x 24 508 x 610 19-5/8 x 23-5/8 1 27.50 FD2CI-2024 20 x 30 508 x 762 19-5/8 x 29-5/8 1 35.00 FD2CI-2030 20 x 36 508 x 914 19-5/8 x 35-5/8 1 41.50 FD2CI-2036 22 x 22 559 x 559 21-5/8 x 21-5/8 1 29.00 FD2CI-2222 22 x 30 559 x 762 21-5/8 x 29-5/8 1 38.00 FD2CI-2230 22 x 36 559 x 914 21-5/8 x 35-5/8 1 44.00 FD2CI-2236 24 x 24 610 x 610 23-5/8 x 23-5/8 1 32.00 FD2CI-2424 24 x 30 610 x 762 23-5/8 x 29-5/8 1 38.50 FD2CI-2430 24 x 36 610 x 914 23-5/8 x 35-5/8 1 46.25 FD2CI-2436 24 x 48 610 x 1219 23-5/8 x 47-5/8 1 61.00 FD2CI-2448 30 x 30 762 x 762 29-5/8 x 29-5/8 1 47.00 FD2CI-3030 30 x 36 762 x 914 29-5/8 x 35-5/8 1 55.00 FD2CI-3036 30 x 48 762 x 1219 29-5/8 x 47-5/8 1 70.50 FD2CI-3048 32 x 32 813 x 813 31-5/8 x 31 5/8 1 53.00 FD2CI-3232 36 x 36 914 x 914 35-5/8 x 35-5/8 1 65.00 FD2CI-3636

҂ Clear Opening = R.O. Width minus 3 1/4” (83mm) Height minus 1/1/2” (39mm)

Other sizes available upon request

ORDER SIZE = OPENING SIZE

SUBMITTAL: FD2CI™ SERIES 2-4 HOUR FIRE-RATED UPWARD-OPENING ACCESS PANELS FOR CEILINGS PAGE 2 OF 2

WWW.ACTIVARCPG.COM © 2017 ACTIVAR CONSTRUCTION PRODUCTS GROUP, INC. 800-554-6077

SELECT BY FIRE RATING

Listing Use Model Listing Min Size W X H Max Size W X H Page

1 HR Combustible Ceiling

FD (Standard) FDS (Standard Stainless) FDW (WB Bead) FDP (Plaster Bead)

WHI 8” x 8” 24” x 36”

1 1/2 HR “B” Label for 2 Hour Wall Wall

FD (Standard) FDS (Standard Stainless) FDW (WB Bead) FDP (Plaster Bead)

UL 8” x 8” 48” x 48”

FD Heavy Gauge (14g Standard) FD2W (Standard Oversized) FD2WI (In-Opening Door) FDRFW (Recessed Trim) FD2L (Laundry Garbage) FD2DW (Double Leaf)

WHI

8” x 8” >48” W or 48” H 16”x 16” 16”x 16” 16”x 16” 18” x 18”

24” x 48” 60” W or 60” H 48” x 60” 48” x 60” 48” x 60” 60” W or 60” H

2 HR Non-Combustible Ceiling

FD (Standard) FDS (Standard Stainless) FDW (WB Bead) FDP (Plaster Bead)

WHI 8” x 8” 24” x 36”

FD2C (Standard Oversized) FD2RFC (Recessed Trim) FD2CTC (Recessed Trim & Door) FD2CI (Combustible, Up-Opening) FD2DC (Double Leaf)

WHI

>24” W or 36” H 8” x 8” 8” x 8” 12” x 12” 18” x 18”

36” W x 48”H 36” x 36” 24” x 36” 36” x 36” 60” x 48”

3 HR Wall FD3W (Standard) FD3RFW (Recessed Trim) FD3DW (Double Leaf)

WHI

12” x 12” 12” x 12” 18 x 18”

48” x 60” 48” x 60” 40” x 60”

3 HR Non-Combustible Ceiling

FD (Standard) FDS (Standard Stainless) FDW (WB Bead) FDP (Plaster Bead)

WHI 8” x 8” 24” x 36”

FD3C (Standard Oversized) FD2CI (Up-Opening) FD3DC (Double Leaf)

WHI

>24” W or 36” H 14” x 14” 18” x 18”

36” w or 48” 32” x 32” 60” W or 60”

SEE INDIVIDUAL PRODUCT PAGES FOR DETAILS ON AVAILABLE SIZES

UL - LISTED BY UL, WHI - LISTED BY INTERTEK WARNOCK HERSEY

FIRE-RATED: ACCESS PANELS SELECTION GUIDE & INDEX

JL Industries now offers a full line of fire-rated access panels including 3 hour, double leaf and specialty models, including the largest sizes in the industry. To help you select the best model for your application - here is the new guide:

INDEX TO CATALOG

Model Description Page Model Description Page

AT Gasketed 13 FD3C/FD3W Fire-Rated, 3 Hr Ceiling and Wall 5

CTE Recessed Plaster Frame, Recessed Door 11 FD Heavy Gauge Fire-Rated, 14 Gauge Heavy Duty 3

CT Framless, Recessed Door 11 HSP 7 Gauge, High Security 14, 15

CTW Wallboard Bead, Recessed Door 11 TMP, TME Recessed Plaster Frame 10

FD, FDS Fire-Rated, Standard, and Stainless 3 Security Locks Security Lock Options 15

FDP Fire-Rated, Recessed Plaster 4 SM Surface-Mount Frame 13

FDW Fire-Rated, Wallboard Bead 4 SP 10 Gauge, Security 14, 15

FD2C/FD2W Fire-Rated, 2 Hr Oversized 5 STC STC-Related Sound Blocking, Insulated 16

FD2D, FD3D Fire-Rated Double Leaf Doors - Large Sizes 7 TM/TMG/TMS Standard Frame/ Galvanized/ Stainless 8

FD2RF, FD3RF Fire-Rated, Recessed Trim 6 TM Options TM Special Features 9

FD2CI, FD3CI Fire-Rated, Upward Opening Door, Ceiling 6 TMW Wallboard Bead 10

FD2WI, FD3WI Fire-Rated, Inward Opening Door, Wall 6 XPA/XPEA Exterior, Galvanized, Insulated/Plasterguard 12

FD2L Fire-Rated, Laundry/Garbage Door 7 XPS/XPES Exterior, Stainless, Insulated/Plasterguard 12

FLOOR DOOR PRODUCT INFORMATION CAN NOW BE FOUND IN A SEPARATE CATALOG

FIRE-RESISTANCE DESIGN

Assembly Usage Disclaimer

BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States

BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States

Design Criteria and Allowable Variances

See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design Criteria and Allowable Variances

Design No. I503

June 06, 2017

Non-load-bearing Horizontal Protective Membrane - 2 Hr

Load Restriction - Limited to the Dead Weight of the Assembly.

# Indicates item is shown for illustrative purposes only as that item may be tested and certified to a standard other than UL 263.

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Cookies on UL

We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and analytics partners. - Learn More

AcceptSettings❯

Cookies on UL

We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and

1. Supporting Structure — Fire-resistance rated. Suitable point of attachment of Perimeter Channels (Item 2).

2. Perimeter Channels — Used to support steel joists at both ends of structure.

Min. 6 in. deep with min. 1-3/8 in. legs and formed from min. No. 16 MSG galv. steel (0.053 in. thick bare metal thickness). Perimeter channels attached to a fire-resistant rated supporting structure (item 1) with fasteners spaced not greater than 18 in. O.C.

at both the top and bottom of the vertical leg. Maximum clear span from vertical leg to vertical leg of the perimeter channels is 8 ft.

2A. Steel Joists — Min. 6 in. wide with min. 1-5/8 in. legs containing folded back flanges and formed from min. No. 16 MSG galv. steel (0.053 in. thick bare metal thickness). Studs to be cut 1/2 in. to 3/4 in. less than the clear span between the vertical legs of the perimeter channels. Studs spaced a max. 16 in. O.C. At each end of the stud, the un-faced side shall be secured to the perimeter channel with one 1/2

in. long pan-head steel screw. Studs are used at each end of the horizontal barrier to terminate the assembly at the adjoining wall.

3. Gypsum Board* — Two layers of nom. 5/8 in. thick, 46 to 54 in. wide, gypsum board installed with long dimension perpendicular to the steel studs. Base layer installed with end joints in adjacent rows staggered min. 64 in. Boards secured to studs and perimeter channels with 1-1/4 in. long Type S steel screws spaced max.

12 in. OC at perimeter and max. 16 in. OC in the field. Face layer installed with end joints in adjacent rows staggered min. 32 in. Boards secured to the studs and perimeter channels with 1-7/8 in. long Type S steel screws spaced max. 12 in. OC at perimeter and max. 16 OC in the field. Face layer end joints staggered min. 16 in.

from base layer joints. Face layer long edge joints staggered min. 8 in. from base layer joints.

Cookies on UL

We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and

AMERICAN GYPSUM CO — Type AG-C

UNITED STATES GYPSUM CO — Type C

USG BORAL DRYWALL SFZ LLC — Type C

4. Joint Tape and Compound — Not Shown — Vinyl, dry or premixed joint compound, applied in two coats to joints and screw heads; paper tape, nom. 2 in.

wide, embedded in first layer of compound over all joints.

5. Fire Damper* — (Optional) — Fire or Combination fire/smoke damper, 48 in. by 48 in. max., located in framed opening lined with single layer of 5/8 in. gypsum board (Item 3). Opening to accommodate damper framed as follows and in accordance with damper manufactures installation document No. 481007 dated July 2015 for Greenheck Fan Corp and part number M-5XXXX for Pottorff. Fire damper assembly evaluated and certified in accordance with Standard UL 555. Refer to UL category

EMME.

A. Joists — Double back-to-back steel joists (Item 2) secured together along centerline of joists with min. three No. 8 by 1/2 in.

steel screws spaced max 24 in. OC.

B. Steel Channel — (Same material as Item 1). One secured to each double joist facing opening with one No. 8 by 1/2 in. steel screw through bottom and top flange at each end. Channel runs length of joists between the edges of the perimeter channel flanges.

C. Steel Channel — (Same material as Item 1). Single steel channel secured to Item 5D with one No. 8 by 1/2 in. steel screw through bottom and top flange at each end.

D. Steel Channel — (Same material as Item 1). Min. 12 in. long channel reinforcement sections employed at each corner of opening. Secured to Item 5B with min. three No. 8 by 1/2 in. steel screws in a triangular pattern.

GREENHECK FAN CORP — Series DFD, FD, FSD

POTTORFF — Series FD, VFD, FSD, CFS

RUSKIN COMPANY — Series (D) IBD, DFD, FSD

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

Cookies on UL

We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and

UL and the UL logo are trademarks of UL LLC © 2018 All Rights Reserved.

Last Updated on 2017-06-06

Design/System/Construction/Assembly Usage Disclaimer

Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials.

Authorities Having Jurisdiction should be consulted before construction.

Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.

When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design.

This is the start of the file's text. The full file is on GovTribe.