1'-6" 5'-4" 1'-6"

2'-0" 2'-6" 2'-6" 2'-6" 2'-6"

1'-6"

2'-6" 2'-6" 2'-0"1'-6"

1'-6" 1'-6" 1'-1 1/2"1'-6"1'-6"1'-1 1/2"

6 1/2" 6 1/2"4"

OVEN NICOVEN NIC

3' -0

2'

-0

3' -0

2' -0

2' -0

HOOD HOOD

G A-201

H A-201

UP

3 R @ 6" EA

2 T @ 11" EA

5'-0 1/2" 8'-4" 5'-0 1/2"

8' -0

SHIMSHIMSHIM

8' -0

4'-1 3/4" 3'-4" 1'-6" 3'-0" 3'-0"

3'-0"

8'-0"

B

3'-0"5'-0" 3'-0 1/4"

OPEN OPEN ICE

ICE

2' -1

0"

8'-0"

MICROWAVE

SHUTTER

J A-201

K A-201

OPEN SHELVING

20'-0 1/4"

2'-0" 3'-0"

10'-0"

10'-0"

11"4" SHIM

1'-1 1/2"

2'-6"

3' -0

2'

-0

3' -0

2' -0

3-COMPARTMENT

SINK

I A-201

SIM

8' -0

3'-4"

A

2'-0"

1'-1"

3'-0" 3'-2 1/2"

1'-6"

2'-0"

1 1/2"

3' -0

2'

-0

3' -0

2' -0

6' -8

I A-201

2' -1

0" 5'

-2

1' -4

" 6'-4"

8' -0

SHIM

2'-0"2'-6"2'-6"

SINK

3' -0

3'-4"

UNDER SINK KNEE PANEL,

MATCH CASEWORK FINISHES

8'-0"

B

1'-6" 2'-6" 2'-6" 2'-6" 1'-6" 1'-6" 3'-4" 4'-0" MIN

OPEN OPEN

J A-201

2' -1

0"

10'-6 1/8"

SOILD END PANELS

2'-1"

3"

6"

2" 2"

4"

2'-1"

4" 4"

3"

6"

5/

8"

/8

6"

1"

2' -0

2"

2'-0"

1/

2" 2" 2"

1'-1 1/2"

1/

2" 2"

3' -0

OVEN

NIC

PROVIDE BLOCKING

AS REQUIRED

3/4" WOOD CABINET

DOOR & SHELF

3/4" WOOD

DRAWER FRONT

1-1/2" SOLID SURFACE

COUNTERTOP 2-HOUR

FIRE-RATED

HOLES FOR SHELF

SUPPORT 1-1/2" OFF

CENTER

CABINET HARDWARE

WOOD BLOCKING

AS REQUIRED

3' -0

3' -0

BASE AS

SCHEDULED

2' -0

BASE AS

SCHEDULED

PROVIDE BLOCKING

AS REQUIRED

3' -0

DRAWER 1

DRAWER 1

DRAWER 2

DRAWER 3

DRAWER 4

CABINET HARDWARE

AS SPECIFIED

3/4" WOOD DRAWER

FRONT

1-1/2" SOLID SURFACE

COUNTERTOP 2-HOUR

FIRE-RATED

UNDER COUNTER

LIGHT FIXTURE, SEE

ELECTRICAL

HOLES FOR SHELF

SUPPORT 1-1/2" OFF

CENTER

CABINET HARDWARE

PROVIDE BLOCKING

AS REQUIRED

1" 2'-1"

3"

6"

2" 2"

4" 2'

-0

PROVIDE BLOCKING

AS REQUIRED

3/4" WOOD CABINET

DOOR & SHELF

3/4" WOOD

DRAWER FRONT

1-1/2" SOLID SURFACE

COUNTERTOP 2-HOUR

FIRE-RATED

3' -0

BASE AS

SCHEDULED

DRAWER 1

1"

2"

1'-1 1/2"

1/

2" 2"

3' -0

UNDER COUNTER

LIGHT FIXTURE, SEE

ELECTRICAL

HOLES FOR SHELF

SUPPORT 1-1/2" OFF

CENTER

CABINET HARDWARE

PROVIDE BLOCKING

AS REQUIRED

4"

4"

3"

2' -1

0"

6" 6" 1'

-6

4' -3

MICROWAVE

NIC

BASE AS

SCHEDULED

PROVIDE BLOCKING

AS REQUIRED

DRAWER 1

DRAWER 2

CABINET HARDWARE

AS SPECIFIED

3/4" WOOD DRAWER

FRONT

1-1/2" SOLID SURFACE

COUTNERTOP 2-HOUR

FIRE-RATED

SHUTTER TRACK

COILING SHUTTER

ASSEMBLE

COILING SHUTTER

GUARD

4"

3"

1/

2"

3' -0

1/

2"

1/ 2"

5' -0

BASE AS

SCHEDULED

PROVIDE BLOCKING

AS REQUIRED

CABINET HARDWARE

3/4" WOOD DRAWER

FRONT

HOLES FOR

ADJUSTABLE SHELF

SUPPORT 1-1/2" OFF

CENTER

3/4" WOOD CABINET

SHELVES

3/4" WOOD CABINET

DOOR & SHELF

3/4" WOOD CABINET

DOOR & SHELF

3/4" WOOD CABINET

DOOR & SHELF

DRAWER 1

DRAWER 2

DRAWER 3DRAWER 1

2-HR FIRE RATED

WALL

1-1/2" SOLID SURFACE

COUTNERTOP 2-HOUR

FIRE-RATED

C O

N

TR

AC

T

N O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

D

2 3

C

4 5

A

B

D

AT

E:

FI

LE

N U

M

BE

R

SI

ZE

SU

BM

IT

TE

D B

Y:

PL

O

T D

AT

E:

D

AT

E D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

C

ES

/C

EN

M O

U N

TA

IN

H O

M E

AI

R

F O

R C

E

BA

SE

141312111098

7654321

AN

SI

D

JA

N U

AR

Y

AS

N

O

TE

D

H D

R E ng in ee rin g, In c.

E

PA

R

KC

EN

TE

R B

LV

D

#1

BO

IS

E, ID

(2

) 3

-7

FA

-1

4- D

-3

/2

7/

C H

AP

EL

K

IT

C H

EN

R

EN

O

VA

TI

O N

, F

AC

IL

IT

Y

M

O U

N

TA

IN

H

O M

E

AI

R F

O R

C E

BA

SE

ID

AH

O

IN

TE

R

IO

R E

LE

VA

TI

O

N S

A-201

A A-101

INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"

B A-101

INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"

C A-101

INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"

D A-101

INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"

E A-101

INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"

G A-101

CASEWORK SECTION

SCALE: 3/4" = 1'-0"

H A-101

CASEWORK SECTION

SCALE: 3/4" = 1'-0"

I A-101

CASEWORK SECTION

SCALE: 3/4" = 1'-0"

J A-101

CASEWORK SECTION

SCALE: 3/4" = 1'-0"

K A-101

CASEWORK SECTION

SCALE: 3/4" = 1'-0"

F A-101

INTERIOR ELEVATION

SCALE: 1/4" = 1'-0"

C O

N

TR

AC

T

N O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

D

2 3

C

4 5

A

B

D

AT

E:

FI

LE

N U

M

BE

R

SI

ZE

SU

BM

IT

TE

D B

Y:

PL

O

T D

AT

E:

D

AT

E D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

C

ES

/C

EN

M O

U N

TA

IN

H O

M E

AI

R

F O

R C

E

BA

SE

141312111098

7654321

AN

SI

D

JA

N U

AR

Y

AS

N

O

TE

D

H D

R E ng in ee rin g, In c.

E

PA

R

KC

EN

TE

R B

LV

D

#1

BO

IS

E, ID

(2

) 3

-7

FA

-1

4- D

-3

/2

7/

C H

AP

EL

K

IT

C H

EN

R

EN

O

VA

TI

O N

, F

AC

IL

IT

Y

M

O U

N

TA

IN

H

O M

E

AI

R F

O R

C E

BA

SE

ID

AH

O

PLUMBING

DHW

DCW

VENT

ACID WASTE

SANITARY

ACID

SAN

WF

RDHW

WALL FAUCET

RECIRCULATING DOMESTIC HOT WATER

DOMESTIC HOT WATER

DOMESTIC COLD WATER

FLOOR CLEANOUT

FLOOR DRAIN W/ TRAP

CO

RL

RD

RS

CWS

CWR

CR

CHWS

CHWR

GCWS

THERMOSTATT

GCWR

C

WALL CLEAN OUT

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

REFRIGERANT STRAINER

CHILLED WATER RETURN

CHILLED WATER SUPPLY

REFRIGERANT SUCTION

REFRIGERANT DISCHARGE (HOT GAS)

REFRIGERANT LIQUID

CHILLED-HOT WATER RETURN

GLYCOL CHILLED WATER RETURN

GLYCOL CHILLED WATER SUPPLY

CHILLED-HOT WATER SUPPLY

THERMOSTATIC EXPANSION VALVE

REFRIGERATION

TEMPERATURE CONTROLS

S

N

OA

E

H

P

PB

HUMIDITY SENSOR

PRESSURE SENSOR

EMCS SENSOR

MANUAL OVER-RIDE SWITCH

NIGHT THERMOSTAT

SENSOR

GENERAL NOTES:

OUTDOOR AIR THERMOSTAT

1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO

THE CONDITIONS ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.

2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY APPEAR IN THIS SET OF

DRAWINGS TO INDICATE SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS

SHEET.

DUCTWORK

20 x 12 SG

700 CFMHPS

HEATING

LPC

FW

PC

FEED WATER

PUMPED CONDENSATE

LPS

MPS

MPC

HTWS

HPC

LOW PRESSURE CONDENSATE

MEDIUM PRESSURE CONDENSATE

HIGH PRESSURE CONDENSATE

LOW PRESSURE STEAM

MEDIUM PRESSURE STEAM

HIGH PRESSURE STEAM

HIGH TEMPERATURE WATER SUPPLY

DOOR GRILLE

DG

12 x 6

20 x 12

D

BBD

FOG

BOILER BLOW-DOWN

FUEL OIL GAGE LINE

FOS

FOF

FOR

GASG

FOV

FUEL OIL FILL

F & T TRAP

FUEL OIL RETURN

FUEL OIL SUPPLY

THERMODYNAMIC TRAP

FUEL OIL TANK VENT

HTWR

HWS

HWR

CWS

CWR

F FLOAT TRAP

THERMOSTATIC TRAP

BUCKET TRAP

HIGH TEMPERATURE WATER RETURN

HOT WATER HEATING RETURN

HOT WATER HEATING SUPPLY

CHILLED WATER RETURN

CHILLED WATER SUPPLY

MODSEC.

VD

OR

FD

AD

SD

AD

AD

GLOBE VALVE

NEEDLE VALVE

STRAINER

HOSE GATE VALVE

GATE VALVE

SOLENOID VALVE

PRESSURE RELIEF VALVE

FLOAT OPERATED VALVE

BALL VALVE

BUTTERFLY VALVE

WAFER CHECK VALVE

O, S, & Y GATE VALVE W/ TAMPER SWITCH

VALVES & FITTINGS

PRESSURE REDUCING VALVE

MOTOR OPERATED GATE VALVE

PLUG VALVE OR BALANCING COCK

CAP

ELBOW UP

TEE UP

TEE DOWN

ELBOW DOWN

UNION

BLIND FLANGE

FLANGE

PIPE INCREASER OR DECREASER

SUPPLY GRILLE (SG)

DIRECTION OF FLOW

SPLITTER DAMPER

FLEXIBLE DUCT

TURNING VANES

SMOKE DAMPER

UNIT HEATER (VERTICAL)

UNIT HEATER (HORIZONTAL)

PARALLEL BLADE DAMPERS

DUCT SECTION (EXHAUST OR RETURN)

DUCT SECTION (SUPPLY)

OPPOSED BLADE DAMPERS

AUTOMATIC DAMPERS MOTOR OPERATED

VOLUME DAMPER MANUAL OPERATION

FLEXIBLE CONNECTION

MECHANICAL LEGEND

M

S

20 x 12 RG

700 CFM

RETURN (RG) OR EXHAUST (EG) GRILLE

(NOTE AT FLR. OR CLG.)

SUPPLY REGISTER (SR)

(A GRILLE + INTEGRAL VOL. CONTROL)

20 x 12 SR

700 CFM

20 x 12 GR

700 CFM

EXHAUST OR RETURN AIR INLET CEILING

(INDICATE TYPE)

SUPPLY OUTLET, CEILING ROUND (TYPE AS SPECIFIED)

INDICATE FLOW DIRECTION

SUPPLY OUTLET, CEILING, RECTANGULAR (TYPE AS SPECIFIED)

INDICATE FLOW DIRECTION

POWER OR GRAVITY ROOF VENTILATOR-EXHAUST

(ERV)

POWER OR GRAVITY ROOF VENTILATOR-SUPPLY (SRV)

POINT OF CHANGE IN DUCT CONSTRUCTION (BY STATIC

PRESSURE CLASS)

DUCT (1ST FIGURE, SIDE SHOWN 2ND FIGURE, SIDE NOT

SHOWN)

ACOUSTICAL LINING DUCT DIMENSIONS FOR

NET FREE AREA

TRANSITIONS: GIVE SIZES

NOTE F.O.T. (FLAT ON TOP) OR

F.O.B. (FLAT ON BOTTOM), IF APPLICABLE

STANDARD BRANCH FOR SUPPLY & RETURN

(NO SPLITTER)

ACCESS DOOR (AD), ACCESS PANEL (AP)

FIRE DAMPER

20 Ø

700 CFM

20 x 12

700 CFM

INCLINED RISE (R) OR DROP (D) ARROW IN

DIRECTION OF AIR FLOW

WH WALL HYDRANT

SEE TEMPERATURE CONTROL DRAWINGS FOR ADDITIONAL LEGEND

NEW TO EXISTING CONNECTION

AI

AO

ANALOG INPUT

DIGITAL OUTPUT

DI DIGITAL INPUT

DO DIGITAL OUTPUT

T

M

EC

H

AN

IC

AL

L

EG

EN

D

M-001

G-1 16x16

1000 CFM

(TYP 3)

XRTU

D-1 8"Ø

250 CFM

(TYP 12)

1 (TYP)

D-1 8"Ø

250 CFM

(TYP 4)

8"Ø TO

WALL CAP

RH-1 RH-1

EF-1

R -1

4x

C

FM

S

CO2

WH-1

12 MD

(TYP)

9(TYP)

MULTI-PURPOSE

ROOM

STORAGE

MECHANICAL

KITCHEN

FD

FD

FDFD

14x12"

4" VENT UP

TO VTR

S-2

3" FS-1

S-1

WH-1

XRTU

CO

2"

4"

YCO

MULTI-PURPOSE

ROOM

STORAGE

MECHANICAL

P-1

ET-1

GI-110

OB-114

S

KITCHEN

S-3

C O

N

TR

AC

T

N O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

D

2 3

C

4 5

A

B

D

AT

E:

FI

LE

N U

M

BE

R

SI

ZE

SU

BM

IT

TE

D B

Y:

PL

O

T D

AT

E:

D

AT

E D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

C

ES

/C

EN

M O

U N

TA

IN

H O

M E

AI

R

F O

R C

E

BA

SE

141312111098

7654321

AN

SI

D

JA

N U

AR

Y

AS

N

O

TE

D

H D

R E ng in ee rin g, In c.

E

PA

R

KC

EN

TE

R B

LV

D

#1

BO

IS

E, ID

(2

) 3

-7

FA

-1

4- D

-3

/2

7/

C H

AP

EL

K

IT

C H

EN

R

EN

O

VA

TI

O N

, F

AC

IL

IT

Y

M

O U

N

TA

IN

H

O M

E

AI

R F

O R

C E

BA

SE

ID

AH

O

KEYNOTES:

PERFORM AIR BALANCE SURVEY OF ALL EXISTING

DIFFUSERS, REGISTERS, GRILLES, AND ROOFTOP UNIT

(XRTU) PRIOR TO ANY DEMOLITION / WORK BEGINNING

AND PROVIDE REPORT. REPLACE EXISTING DIFFUSERS,

REGISTERS, GRILLES AND COORDINATE LOCATION

WITHIN NEW CEILING GRID. RECONNECT TO EXISTING

DUCT BRANCH AND BALANCE TO CFM SHOWN.

EXTEND NEW 4" SANITARY AND CONNECT TO EXISTING

APPROXIMATELY AS SHOWN. VERIFY EXISTING INVERT

AND CONTACT COR IF DEPTH IS NOT SUFFICIENT FOR

NEW WORK.

CONNECT NEW NATURAL GAS LINE TO EXISTING,

EXTEND INTO BUILDING AND CONNECT TO NEW GAS

APPLIANCES. CONTRACTOR TO VERIFY EXISTING GAS

PRESSURE REGULATOR CAN HANDLE INCREASED LOAD

AND REPLACE IF NECESSARY.

SOLENOID VALVE IN NATURAL GAS SERVICE TO

KITCHEN. VALVE SHALL CLOSE ON ACTIVATION OF THE

BUILDING FIRE ALARM OR MANUAL SWITCH.

CONNECT NEW 1-1/2" DCW INTO EXISTING MAIN

LOCATED WITHIN THE CRAWL SPACE AND EXTEND UP

INTO STORAGE ROOM AND ROUTE TO NEW WATER

HEATER AND FIXTURES AS SHOWN.

EXTEND 3/4" DCW, 3/4" DHW AND 1/2" DHWR THRU BACK

OF CABINETRY, IN CONDITIONED SPACE, TO

3-COMPARTMENT SINK. INSULATE ALL PIPING WITH PVC

JACKETED INSULATION.

SAW CUT / PATCH FLOOR AND INSTALL 2" SAN WITHIN

THE CRAWL SPACE TO SINK S-1 & S-3. INSTALL 3" PVC

PIPE WITH LONG SWEEP ELBOW WITHIN CRAWL SPACE

FROM MECH ROOM TO 6" ABOVE FLOOR UNDER SINK

CABINETRY. ROUTE 1/2" TYPE 'L' SOFT COPPER DCW,

DHW, & DHWR LINES WITHIN 3" PVC PIPE TO SINKS.

3" COMBUSTION AIR INTAKE AND EXHAUST SERVING

WATER HEATER TO DISCHARGE THRU WALL WITH

MANUFACTURER PROVIDED CONCENTRIC VENT KIT.

VERIFY BALANCING DAMPERS EXIST IN ALL DUCT

BRANCHES AND INSTALL NEW IF ANY ARE MISSING.

GREASE INTERCEPTOR UNDER 3 COMPARTMENT SINK,

DISCHARGE TO FLOOR SINK.

MANUAL SWITCH TO CLOSE NATURAL GAS SOLENOID

SHUT OFF VALVE SERVING KITCHEN GAS APPLIANCES.

FAN CONTROLLER, COORDINATE LOCATION WITH ALL

DISCIPLINES.

CO2 SENSOR FOR CONTROL OF EF-1

OUTLET BOX (OB-1) FOR WATER CONNECTION TO ICE

MAKER IN REFRIGERATOR. ROUTE 1/2" DCW FROM MAIN

TO OB-1 AS SHOWN.

REMOVE OUTSIDE AIR (OA) HOOD FROM XRTU AND

REPLACE WITH NEW PLENUM FULL SIZE OF OA

OPENING. EXTEND 24x24 OA DUCT OVER TO, AND UP

BUILDING WALL TERMINATING WITH A GOOSENECK

FITTING WITH BOTTOM OF OPENING AT MIN. 10 FT.

ABOVE FINISHED GRADE.

HVAC SHUTDOWN SWITCH.

CAP AND SEAL EXISTING RETURN AIR DUCT BRANCH.

H

VA

C A

N D

P

LU

M

BI

N G

P

LA

N S

M-101

GENERAL NOTES:

(APPLY TO ALL MECHANICAL SHEETS)

1. THE EXISTING LAYOUTS INDICATED ON THESE PLANS ARE

BASED ON THE EXISTING PLANS AND LIMITED FIELD

OBSERVATION. IT IS THE CONTRACTOR'S RESPONSIBILITY

TO VERIFY ACTUAL CONDITIONS AND MAKE NECESSARY

CHANGES TO ACCOMMODATE THE INSTALLATION OF NEW

WORK AT NO ADDITIONAL COST TO THE COR. UNCOVERED

SYSTEMS SHALL BE CAREFULLY IDENTIFIED PRIOR TO ANY

MODIFICATIONS OCCURRING. EXISTING TO REMAIN WORK IS

SHOWN HALF TONE, DEMOLITION WORK IS SHOWN BOLD

AND CROSSHATCHED.

2. COR SHALL BE GIVEN THE OPTION TO RETAIN ANY

REMOVED EQUIPMENT FOR SPARE PARTS CONTRACTOR

SHALL PROPERLY DISPOSE OF ALL EQUIPMENT THAT THE

COR DOES NOT WISH TO RETAIN.

3. REMOVE/REPLACE CEILING/WALL AND CUT/PATCH

CEILING/WALL TO ACCOMMODATE WORK SHOWN.

4. ALL EXISTING AND DEMOLITION DUCTWORK/PIPING SIZES

ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL

FIELD VERIFY ALL EXISTING DUCTWORK/PIPE SIZES PRIOR

TO STARTING ANY WORK.

5. REMOVE ALL EXISTING PIPING/DUCTWORK NO LONGER

BEING USED. MODIFY EXISTING PIPING/DUCTWORK BEING

USED TO ACCOMMODATE INSTALLATION OF NEW HVAC

EQUIPMENT, DUCTWORK AND PIPING.

6. ANY REFRIGERANT EVACUATION AND RECOVERY

ASSOCIATED WITH THE DEMOLITION WORK IS THE

CONTRACTOR'S RESPONSIBILITY TO REMOVE FROM THE

SITE.

7. EXISTING EQUIPMENT LABELED WITH AN 'X' (I.E. XRTU) IS

EXISTING TO REMAIN.

8. (E) DENOTES EXISTING PIPING SYSTEM, I.E. (E) DCW.

16HVAC PLAN PLUMBING PLAN

NN

N

TR

AC

T

N O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

D

2 3

C

4 5

A

B

D

AT

E:

FI

LE

N U

M

BE

R

SI

ZE

SU

BM

IT

TE

D B

Y:

PL

O

T D

AT

E:

D

AT

E D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

C

ES

/C

EN

M O

U N

TA

IN

H O

M E

AI

R

F O

R C

E

BA

SE

141312111098

7654321

AN

SI

D

JA

N U

AR

Y

AS

N

O

TE

D

H D

R E ng in ee rin g, In c.

E

PA

R

KC

EN

TE

R B

LV

D

#1

BO

IS

E, ID

(2

) 3

-7

FA

-1

4- D

-3

/2

7/

C H

AP

EL

K

IT

C H

EN

R

EN

O

VA

TI

O N

, F

AC

IL

IT

Y

M

O U

N

TA

IN

H

O M

E

AI

R F

O R

C E

BA

SE

ID

AH

O

M

EC

H

AN

IC

AL

D

ET

AI

LS

M-501

DCW

DHW

COMBUSTION AIR

INTAKE AND EXHAUST

SHUT-OFF VALVE (TYP)

THERMOMETER

UNION (TYPICAL)

ASME RATED TEMP &

PRESSURE RELIEF

VALVE

PIPE TO FLOOR DRAIN

4" CONCRETE PAD

FINISHED FLOOR

DIRT LEG

UNION

GAS COCK

G

DHWR

EXPANSION

TANK

CHECK

VALVE (TYP)

DOMESTIC HOT WATER

RECIRC PUMP

SCALE: NOT TO SCALE

C4

N

TR

AC

T

N O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

D

2 3

C

4 5

A

B

D

AT

E:

FI

LE

N U

M

BE

R

SI

ZE

SU

BM

IT

TE

D B

Y:

PL

O

T D

AT

E:

D

AT

E D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

C

ES

/C

EN

M O

U N

TA

IN

H O

M E

AI

R

F O

R C

E

BA

SE

141312111098

7654321

AN

SI

D

JA

N U

AR

Y

AS

N

O

TE

D

H D

R E ng in ee rin g, In c.

E

PA

R

KC

EN

TE

R B

LV

D

#1

BO

IS

E, ID

(2

) 3

-7

FA

-1

4- D

-3

/2

7/

C H

AP

EL

K

IT

C H

EN

R

EN

O

VA

TI

O N

, F

AC

IL

IT

Y

M

O U

N

TA

IN

H

O M

E

AI

R F

O R

C E

BA

SE

ID

AH

O

M

EC

H

AN

IC

AL

S C

H

ED

U

LE

S

M-601

MD

EXISTING

PANEL "C"

REFRIGERATOR

PANEL "D":6

PANEL "D":10

PANEL "D":8

MICROWAVE

BELOW COUNTER

GFCI

ICE

MAKER

PANEL "D":4

PANEL "D":12

GARBAGE

DISPOSAL

DISHWASHER

GFCI

GFCI

GFCIGFCIGFCI

GFCI

GFCI

GFCI

GFCI

PANEL "D":14

PANEL "D":16

PANEL "D":18

PANEL "D":20

PANEL "D":24 PANEL "D":26 PANEL "D":28

PANEL "D":9

PANEL "D":7

J J

PANEL "D":21

PANEL "D":23

HOOD

HOOD

PANEL "D":13

GAS

OVEN

GAS

OVEN

PANEL "D":11

EF-1

WH-1

PANEL "D":15

J J

PANEL "D":1,3

PANEL "D":17,19

NEW

PANEL "D"

WALL

OVEN

WALL OVEN

PANEL "D":29

NAC

PANEL "D":27

PANEL "D":25

MD-1

FAN CONTROLLER

MULTI-PURPOSE

ROOM

STORAGE

MECHANICAL

PANEL "D":33

P-1

KITCHEN

MD

S

MD

L1 L1 L1

L1 L1 L1

L1 L1 L1

L1 L1 L1

L1 L1 L1

E1

A1

A1 A1 A1

A1

A1 A1 A1 D1

D1 D1 D1 D1 a a a a b b b b b b a

3b 3a

E1 c c c c c2

EXISTING

PANEL "C"

PANEL "D":2

J

PANEL "D":5

RETRACTABLE SCREEN

POWER CONNECTION

NEW

PANEL "D"

MULTI-PURPOSE

ROOM

KITCHEN

MECHANICAL

TO EXISTING

LIGHTING CIRCUIT

C O

N

TR

AC

T

N O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

D

2 3

C

4 5

A

B

D

AT

E:

FI

LE

N U

M

BE

R

SI

ZE

SU

BM

IT

TE

D B

Y:

PL

O

T D

AT

E:

D

AT

E D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

C

ES

/C

EN

M O

U N

TA

IN

H O

M E

AI

R

F O

R C

E

BA

SE

141312111098

7654321

AN

SI

D

JA

N U

AR

Y

AS

N

O

TE

D

H D

R E ng in ee rin g, In c.

E

PA

R

KC

EN

TE

R B

LV

D

#1

BO

IS

E, ID

(2

) 3

-7

FA

-1

4- D

-3

/2

7/

C H

AP

EL

K

IT

C H

EN

R

EN

O

VA

TI

O N

, F

AC

IL

IT

Y

M

O U

N

TA

IN

H

O M

E

AI

R F

O R

C E

BA

SE

ID

AH

O

EL

EC

TR

IC

AL

P

LA

N

E-101

L.

R

AK

SI

N

L.

R

AK

SI

N W

. D

AV

ID

SO

N

M . D

O N

LE

Y

LIGHT FIXTURES:

A1 MFR: METALUX AP SERIES CWPLD LED

LAMPING: AS REQUIRED

L1 MFR: METALUX SKY RIDGE LED 2'x4' GRID CEILING

LAMPING: AS REQUIRED.

D1 MFR: LITHONIA LIGHTING 6" LDN6 LED DOWN LIGHT

LAMPING: AS REQUIRED

E1 MFR: THE EXIT LIGHT CO. COMBO2 LED EXIT + EM LIGHT

RED LETTERING

SELF-POWERED WITH NICAD BATTERY

SELF-DIAGNOSTIC

CEILING/PENDANT-MOUNTED

LUMINAIRE 1'x4'- LED

X

CEILING/PENDANT-MOUNTED

LUMINAIRE - LED

X

LEGEND:

EXISTING LIGHTING PANELBOARD

LIGHTING FIXTURE SUBSCRIPTS:

X - INDICATES FIXTURE TYPE PER

LIGHTING FIXTURE SCHEDULE

SINGLE-FACED WALL MOUNTED

COMBINATION EXIT AND

EMERGENCY LIGHT

FIELD VERIFY ALL MEASURMENTS FOR CONSTRUCTION AND

MATERIAL QUANTITIES.

FIELD VERIFY ALL MEASURMENTS FOR CONSTRUCTION AND

MATERIAL QUANTITIES.

KEYNOTES:

RELOCATE EXISTING RECEPTACLES PER NEW

ROOM DESIGNATION. MAINTAIN ASSOCIATED

EXISTING POWER CIRCUITS. COORDINATE

LOCATIONS WITH OWNER PRIOR TO RELOCATION.

NEW OWNER FURNISHED RETRACTABLE

PROJECTOR SCREEN.

RELOCATE EXISTING CEILING MOUNTED

PROJECTOR RECEPTACLE AND ASSOCIATED

POWER AND COMMUNICATIONS CIRCUITS. SEE

LIGHTING PLAN FOR NEW LOCATION.

RELOCATED PROJECTOR RECEPTACLE.

RELOCATE EXISTING BIG SCREEN TV SET AND

ASSOCIATED POWER AND COMMUNICATIONS

CIRCUITS PER OWNER DIRECTION.

RECEPTACLES LOCATED ABOVE COUNTER.

CONNECT NEW EXIT LIGHT TO EXISTING

NOT-SWITCHED LIGHTING CIRCUIT.

GENERAL NOTES:

1. IN MULTI-PURPOSE ROOM REPLACE ALL

EXISTING CEILING GRID MOUNTED LIGHT

FIXTURES WITH NEW FIXTURES.

RECONNECT NEW FIXTURES TO EXISTING

LIGHT CIRCUITS AND SWITCHES.

2. IN KITCHEN ROOM 101 SUSPEND LIGHT

FIXTURES 16 INCHES BELOW CEILING

UTILIZING AIRCRAFT CABLE.

3. IN MECHANICAL ROOM 104 REMOVE

EXISTING LIGHT FIXTURES TO ALLOW

CEILING REPLACEMENT. REINSTALL THE

LIGHT FIXTURES AFTER CEILING

REPLACEMENT IS COMPLETE.

DUPLEX RECEPTACLE, NEMA 5-20R

CEILING/RECESSED-MOUNTED

LUMINAIRE 2'x4'- LED

X

X

X

Y TOGGLE SWITCH

SUBSCRIPTS:

X - INDICATES TYPE

NONE - SINGLE POLE

3 - THREE-WAY

Y - INDICATES CONTROLLING LIGHT

QUADPLEX RECEPTACLE, NEMA 5-20R 6

Y

Y

Y - INDICATES CONTROLLING SWITCH

NEW LIGHTING PANELBOARD

HOME RUN TO PANEL, 2 #12, 1 #12G,

IN 3/4"C UNLESS OTHERWISE NOTED

POWER PLAN