Attachment_2_-_Design_Drawings2.pdf
PDF 548 KB Posted
- Attached to
- Chapel Kitchen Renovation Federal contract opportunity
- Solicitation number
- FA489719BA009
About this file
Attachment 2 - Design Drawings Part2
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_FA489719BA0090001.pdf | ||
| Amendment_FA489719BA0090002.pdf | ||
| Attachment_10_-_Utilities_Map.pdf | ||
| Attachment_9_-_Asbestos_and_Lead_Inspection.pdf | ||
| Attachment_8_-_FSRM_PCR.pdf | ||
| Amendment_FA489719BA0090002.pdf | ||
| Attachment_7_-_Questions_and_Answers.pdf | ||
| Attachment_11_-_Addendum_1.pdf | ||
| Amendment_FA489719BA0090001.pdf | ||
| Attachment_3_-_PCR_Appendices2.pdf | ||
| Attachment_1_-_Chapel_Kitchen_SOW.pdf | ||
| Attachment_2_-_Design_Drawings3.pdf | ||
| Solicitation_-_FA489719BA009.pdf | ||
| Attachment_4_-_Wage_Determinations.pdf | ||
| Attachment_5_-_Grand_View_Gate_Access_Information.pdf | ||
| Attachment_6_-_SFS_FORM_30.pdf | ||
| Attachment_2_-_Design_Drawings1.pdf | ||
| Attachment_3_-_PCR_Appendices1.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1'-6" 5'-4" 1'-6"
2'-0" 2'-6" 2'-6" 2'-6" 2'-6"
1'-6"
2'-6" 2'-6" 2'-0"1'-6"
1'-6" 1'-6" 1'-1 1/2"1'-6"1'-6"1'-1 1/2"
6 1/2" 6 1/2"4"
OVEN NICOVEN NIC
3' -0
2'
-0
3' -0
2' -0
2' -0
HOOD HOOD
G A-201
H A-201
UP
3 R @ 6" EA
2 T @ 11" EA
5'-0 1/2" 8'-4" 5'-0 1/2"
8' -0
SHIMSHIMSHIM
8' -0
4'-1 3/4" 3'-4" 1'-6" 3'-0" 3'-0"
3'-0"
8'-0"
B
3'-0"5'-0" 3'-0 1/4"
OPEN OPEN ICE
ICE
2' -1
0"
8'-0"
MICROWAVE
SHUTTER
J A-201
K A-201
OPEN SHELVING
20'-0 1/4"
2'-0" 3'-0"
10'-0"
10'-0"
11"4" SHIM
1'-1 1/2"
2'-6"
3' -0
2'
-0
3' -0
2' -0
3-COMPARTMENT
SINK
I A-201
SIM
8' -0
3'-4"
A
2'-0"
1'-1"
3'-0" 3'-2 1/2"
1'-6"
2'-0"
1 1/2"
3' -0
2'
-0
3' -0
2' -0
6' -8
I A-201
2' -1
0" 5'
-2
1' -4
" 6'-4"
8' -0
SHIM
2'-0"2'-6"2'-6"
SINK
3' -0
3'-4"
UNDER SINK KNEE PANEL,
MATCH CASEWORK FINISHES
8'-0"
B
1'-6" 2'-6" 2'-6" 2'-6" 1'-6" 1'-6" 3'-4" 4'-0" MIN
OPEN OPEN
J A-201
2' -1
0"
10'-6 1/8"
SOILD END PANELS
2'-1"
3"
6"
2" 2"
4"
2'-1"
4" 4"
3"
6"
5/
8"
/8
6"
1"
2' -0
2"
2'-0"
1/
2" 2" 2"
1'-1 1/2"
1/
2" 2"
3' -0
OVEN
NIC
PROVIDE BLOCKING
AS REQUIRED
3/4" WOOD CABINET
DOOR & SHELF
3/4" WOOD
DRAWER FRONT
1-1/2" SOLID SURFACE
COUNTERTOP 2-HOUR
FIRE-RATED
HOLES FOR SHELF
SUPPORT 1-1/2" OFF
CENTER
CABINET HARDWARE
WOOD BLOCKING
AS REQUIRED
3' -0
3' -0
BASE AS
SCHEDULED
2' -0
BASE AS
SCHEDULED
PROVIDE BLOCKING
AS REQUIRED
3' -0
DRAWER 1
DRAWER 1
DRAWER 2
DRAWER 3
DRAWER 4
CABINET HARDWARE
AS SPECIFIED
3/4" WOOD DRAWER
FRONT
1-1/2" SOLID SURFACE
COUNTERTOP 2-HOUR
FIRE-RATED
UNDER COUNTER
LIGHT FIXTURE, SEE
ELECTRICAL
HOLES FOR SHELF
SUPPORT 1-1/2" OFF
CENTER
CABINET HARDWARE
PROVIDE BLOCKING
AS REQUIRED
1" 2'-1"
3"
6"
2" 2"
4" 2'
-0
PROVIDE BLOCKING
AS REQUIRED
3/4" WOOD CABINET
DOOR & SHELF
3/4" WOOD
DRAWER FRONT
1-1/2" SOLID SURFACE
COUNTERTOP 2-HOUR
FIRE-RATED
3' -0
BASE AS
SCHEDULED
DRAWER 1
1"
2"
1'-1 1/2"
1/
2" 2"
3' -0
UNDER COUNTER
LIGHT FIXTURE, SEE
ELECTRICAL
HOLES FOR SHELF
SUPPORT 1-1/2" OFF
CENTER
CABINET HARDWARE
PROVIDE BLOCKING
AS REQUIRED
4"
4"
3"
2' -1
0"
6" 6" 1'
-6
4' -3
MICROWAVE
NIC
BASE AS
SCHEDULED
PROVIDE BLOCKING
AS REQUIRED
DRAWER 1
DRAWER 2
CABINET HARDWARE
AS SPECIFIED
3/4" WOOD DRAWER
FRONT
1-1/2" SOLID SURFACE
COUTNERTOP 2-HOUR
FIRE-RATED
SHUTTER TRACK
COILING SHUTTER
ASSEMBLE
COILING SHUTTER
GUARD
4"
3"
1/
2"
3' -0
1/
2"
1/ 2"
5' -0
BASE AS
SCHEDULED
PROVIDE BLOCKING
AS REQUIRED
CABINET HARDWARE
3/4" WOOD DRAWER
FRONT
HOLES FOR
ADJUSTABLE SHELF
SUPPORT 1-1/2" OFF
CENTER
3/4" WOOD CABINET
SHELVES
3/4" WOOD CABINET
DOOR & SHELF
3/4" WOOD CABINET
DOOR & SHELF
3/4" WOOD CABINET
DOOR & SHELF
DRAWER 1
DRAWER 2
DRAWER 3DRAWER 1
2-HR FIRE RATED
WALL
1-1/2" SOLID SURFACE
COUTNERTOP 2-HOUR
FIRE-RATED
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
IN
TE
R
IO
R E
LE
VA
TI
O
N S
A-201
A A-101
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
B A-101
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
C A-101
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
D A-101
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
E A-101
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
G A-101
CASEWORK SECTION
SCALE: 3/4" = 1'-0"
H A-101
CASEWORK SECTION
SCALE: 3/4" = 1'-0"
I A-101
CASEWORK SECTION
SCALE: 3/4" = 1'-0"
J A-101
CASEWORK SECTION
SCALE: 3/4" = 1'-0"
K A-101
CASEWORK SECTION
SCALE: 3/4" = 1'-0"
F A-101
INTERIOR ELEVATION
SCALE: 1/4" = 1'-0"
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
PLUMBING
DHW
DCW
VENT
ACID WASTE
SANITARY
ACID
SAN
WF
RDHW
WALL FAUCET
RECIRCULATING DOMESTIC HOT WATER
DOMESTIC HOT WATER
DOMESTIC COLD WATER
FLOOR CLEANOUT
FLOOR DRAIN W/ TRAP
CO
RL
RD
RS
CWS
CWR
CR
CHWS
CHWR
GCWS
THERMOSTATT
GCWR
C
WALL CLEAN OUT
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
REFRIGERANT STRAINER
CHILLED WATER RETURN
CHILLED WATER SUPPLY
REFRIGERANT SUCTION
REFRIGERANT DISCHARGE (HOT GAS)
REFRIGERANT LIQUID
CHILLED-HOT WATER RETURN
GLYCOL CHILLED WATER RETURN
GLYCOL CHILLED WATER SUPPLY
CHILLED-HOT WATER SUPPLY
THERMOSTATIC EXPANSION VALVE
REFRIGERATION
TEMPERATURE CONTROLS
S
N
OA
E
H
P
PB
HUMIDITY SENSOR
PRESSURE SENSOR
EMCS SENSOR
MANUAL OVER-RIDE SWITCH
NIGHT THERMOSTAT
SENSOR
GENERAL NOTES:
OUTDOOR AIR THERMOSTAT
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO
THE CONDITIONS ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY APPEAR IN THIS SET OF
DRAWINGS TO INDICATE SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS
SHEET.
DUCTWORK
20 x 12 SG
700 CFMHPS
HEATING
LPC
FW
PC
FEED WATER
PUMPED CONDENSATE
LPS
MPS
MPC
HTWS
HPC
LOW PRESSURE CONDENSATE
MEDIUM PRESSURE CONDENSATE
HIGH PRESSURE CONDENSATE
LOW PRESSURE STEAM
MEDIUM PRESSURE STEAM
HIGH PRESSURE STEAM
HIGH TEMPERATURE WATER SUPPLY
DOOR GRILLE
DG
12 x 6
20 x 12
D
BBD
FOG
BOILER BLOW-DOWN
FUEL OIL GAGE LINE
FOS
FOF
FOR
GASG
FOV
FUEL OIL FILL
F & T TRAP
FUEL OIL RETURN
FUEL OIL SUPPLY
THERMODYNAMIC TRAP
FUEL OIL TANK VENT
HTWR
HWS
HWR
CWS
CWR
F FLOAT TRAP
THERMOSTATIC TRAP
BUCKET TRAP
HIGH TEMPERATURE WATER RETURN
HOT WATER HEATING RETURN
HOT WATER HEATING SUPPLY
CHILLED WATER RETURN
CHILLED WATER SUPPLY
MODSEC.
VD
OR
FD
AD
SD
AD
AD
GLOBE VALVE
NEEDLE VALVE
STRAINER
HOSE GATE VALVE
GATE VALVE
SOLENOID VALVE
PRESSURE RELIEF VALVE
FLOAT OPERATED VALVE
BALL VALVE
BUTTERFLY VALVE
WAFER CHECK VALVE
O, S, & Y GATE VALVE W/ TAMPER SWITCH
VALVES & FITTINGS
PRESSURE REDUCING VALVE
MOTOR OPERATED GATE VALVE
PLUG VALVE OR BALANCING COCK
CAP
ELBOW UP
TEE UP
TEE DOWN
ELBOW DOWN
UNION
BLIND FLANGE
FLANGE
PIPE INCREASER OR DECREASER
SUPPLY GRILLE (SG)
DIRECTION OF FLOW
SPLITTER DAMPER
FLEXIBLE DUCT
TURNING VANES
SMOKE DAMPER
UNIT HEATER (VERTICAL)
UNIT HEATER (HORIZONTAL)
PARALLEL BLADE DAMPERS
DUCT SECTION (EXHAUST OR RETURN)
DUCT SECTION (SUPPLY)
OPPOSED BLADE DAMPERS
AUTOMATIC DAMPERS MOTOR OPERATED
VOLUME DAMPER MANUAL OPERATION
FLEXIBLE CONNECTION
MECHANICAL LEGEND
M
S
20 x 12 RG
700 CFM
RETURN (RG) OR EXHAUST (EG) GRILLE
(NOTE AT FLR. OR CLG.)
SUPPLY REGISTER (SR)
(A GRILLE + INTEGRAL VOL. CONTROL)
20 x 12 SR
700 CFM
20 x 12 GR
700 CFM
EXHAUST OR RETURN AIR INLET CEILING
(INDICATE TYPE)
SUPPLY OUTLET, CEILING ROUND (TYPE AS SPECIFIED)
INDICATE FLOW DIRECTION
SUPPLY OUTLET, CEILING, RECTANGULAR (TYPE AS SPECIFIED)
INDICATE FLOW DIRECTION
POWER OR GRAVITY ROOF VENTILATOR-EXHAUST
(ERV)
POWER OR GRAVITY ROOF VENTILATOR-SUPPLY (SRV)
POINT OF CHANGE IN DUCT CONSTRUCTION (BY STATIC
PRESSURE CLASS)
DUCT (1ST FIGURE, SIDE SHOWN 2ND FIGURE, SIDE NOT
SHOWN)
ACOUSTICAL LINING DUCT DIMENSIONS FOR
NET FREE AREA
TRANSITIONS: GIVE SIZES
NOTE F.O.T. (FLAT ON TOP) OR
F.O.B. (FLAT ON BOTTOM), IF APPLICABLE
STANDARD BRANCH FOR SUPPLY & RETURN
(NO SPLITTER)
ACCESS DOOR (AD), ACCESS PANEL (AP)
FIRE DAMPER
20 Ø
700 CFM
20 x 12
700 CFM
INCLINED RISE (R) OR DROP (D) ARROW IN
DIRECTION OF AIR FLOW
WH WALL HYDRANT
SEE TEMPERATURE CONTROL DRAWINGS FOR ADDITIONAL LEGEND
NEW TO EXISTING CONNECTION
AI
AO
ANALOG INPUT
DIGITAL OUTPUT
DI DIGITAL INPUT
DO DIGITAL OUTPUT
T
M
EC
H
AN
IC
AL
L
EG
EN
D
M-001
G-1 16x16
1000 CFM
(TYP 3)
XRTU
D-1 8"Ø
250 CFM
(TYP 12)
1 (TYP)
D-1 8"Ø
250 CFM
(TYP 4)
8"Ø TO
WALL CAP
RH-1 RH-1
EF-1
R -1
4x
C
FM
S
CO2
WH-1
12 MD
(TYP)
9(TYP)
MULTI-PURPOSE
ROOM
STORAGE
MECHANICAL
KITCHEN
FD
FD
FDFD
14x12"
4" VENT UP
TO VTR
S-2
3" FS-1
S-1
WH-1
XRTU
CO
2"
4"
YCO
MULTI-PURPOSE
ROOM
STORAGE
MECHANICAL
P-1
ET-1
GI-110
OB-114
S
KITCHEN
S-3
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
KEYNOTES:
PERFORM AIR BALANCE SURVEY OF ALL EXISTING
DIFFUSERS, REGISTERS, GRILLES, AND ROOFTOP UNIT
(XRTU) PRIOR TO ANY DEMOLITION / WORK BEGINNING
AND PROVIDE REPORT. REPLACE EXISTING DIFFUSERS,
REGISTERS, GRILLES AND COORDINATE LOCATION
WITHIN NEW CEILING GRID. RECONNECT TO EXISTING
DUCT BRANCH AND BALANCE TO CFM SHOWN.
EXTEND NEW 4" SANITARY AND CONNECT TO EXISTING
APPROXIMATELY AS SHOWN. VERIFY EXISTING INVERT
AND CONTACT COR IF DEPTH IS NOT SUFFICIENT FOR
NEW WORK.
CONNECT NEW NATURAL GAS LINE TO EXISTING,
EXTEND INTO BUILDING AND CONNECT TO NEW GAS
APPLIANCES. CONTRACTOR TO VERIFY EXISTING GAS
PRESSURE REGULATOR CAN HANDLE INCREASED LOAD
AND REPLACE IF NECESSARY.
SOLENOID VALVE IN NATURAL GAS SERVICE TO
KITCHEN. VALVE SHALL CLOSE ON ACTIVATION OF THE
BUILDING FIRE ALARM OR MANUAL SWITCH.
CONNECT NEW 1-1/2" DCW INTO EXISTING MAIN
LOCATED WITHIN THE CRAWL SPACE AND EXTEND UP
INTO STORAGE ROOM AND ROUTE TO NEW WATER
HEATER AND FIXTURES AS SHOWN.
EXTEND 3/4" DCW, 3/4" DHW AND 1/2" DHWR THRU BACK
OF CABINETRY, IN CONDITIONED SPACE, TO
3-COMPARTMENT SINK. INSULATE ALL PIPING WITH PVC
JACKETED INSULATION.
SAW CUT / PATCH FLOOR AND INSTALL 2" SAN WITHIN
THE CRAWL SPACE TO SINK S-1 & S-3. INSTALL 3" PVC
PIPE WITH LONG SWEEP ELBOW WITHIN CRAWL SPACE
FROM MECH ROOM TO 6" ABOVE FLOOR UNDER SINK
CABINETRY. ROUTE 1/2" TYPE 'L' SOFT COPPER DCW,
DHW, & DHWR LINES WITHIN 3" PVC PIPE TO SINKS.
3" COMBUSTION AIR INTAKE AND EXHAUST SERVING
WATER HEATER TO DISCHARGE THRU WALL WITH
MANUFACTURER PROVIDED CONCENTRIC VENT KIT.
VERIFY BALANCING DAMPERS EXIST IN ALL DUCT
BRANCHES AND INSTALL NEW IF ANY ARE MISSING.
GREASE INTERCEPTOR UNDER 3 COMPARTMENT SINK,
DISCHARGE TO FLOOR SINK.
MANUAL SWITCH TO CLOSE NATURAL GAS SOLENOID
SHUT OFF VALVE SERVING KITCHEN GAS APPLIANCES.
FAN CONTROLLER, COORDINATE LOCATION WITH ALL
DISCIPLINES.
CO2 SENSOR FOR CONTROL OF EF-1
OUTLET BOX (OB-1) FOR WATER CONNECTION TO ICE
MAKER IN REFRIGERATOR. ROUTE 1/2" DCW FROM MAIN
TO OB-1 AS SHOWN.
REMOVE OUTSIDE AIR (OA) HOOD FROM XRTU AND
REPLACE WITH NEW PLENUM FULL SIZE OF OA
OPENING. EXTEND 24x24 OA DUCT OVER TO, AND UP
BUILDING WALL TERMINATING WITH A GOOSENECK
FITTING WITH BOTTOM OF OPENING AT MIN. 10 FT.
ABOVE FINISHED GRADE.
HVAC SHUTDOWN SWITCH.
CAP AND SEAL EXISTING RETURN AIR DUCT BRANCH.
H
VA
C A
N D
P
LU
M
BI
N G
P
LA
N S
M-101
GENERAL NOTES:
(APPLY TO ALL MECHANICAL SHEETS)
1. THE EXISTING LAYOUTS INDICATED ON THESE PLANS ARE
BASED ON THE EXISTING PLANS AND LIMITED FIELD
OBSERVATION. IT IS THE CONTRACTOR'S RESPONSIBILITY
TO VERIFY ACTUAL CONDITIONS AND MAKE NECESSARY
CHANGES TO ACCOMMODATE THE INSTALLATION OF NEW
WORK AT NO ADDITIONAL COST TO THE COR. UNCOVERED
SYSTEMS SHALL BE CAREFULLY IDENTIFIED PRIOR TO ANY
MODIFICATIONS OCCURRING. EXISTING TO REMAIN WORK IS
SHOWN HALF TONE, DEMOLITION WORK IS SHOWN BOLD
AND CROSSHATCHED.
2. COR SHALL BE GIVEN THE OPTION TO RETAIN ANY
REMOVED EQUIPMENT FOR SPARE PARTS CONTRACTOR
SHALL PROPERLY DISPOSE OF ALL EQUIPMENT THAT THE
COR DOES NOT WISH TO RETAIN.
3. REMOVE/REPLACE CEILING/WALL AND CUT/PATCH
CEILING/WALL TO ACCOMMODATE WORK SHOWN.
4. ALL EXISTING AND DEMOLITION DUCTWORK/PIPING SIZES
ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL
FIELD VERIFY ALL EXISTING DUCTWORK/PIPE SIZES PRIOR
TO STARTING ANY WORK.
5. REMOVE ALL EXISTING PIPING/DUCTWORK NO LONGER
BEING USED. MODIFY EXISTING PIPING/DUCTWORK BEING
USED TO ACCOMMODATE INSTALLATION OF NEW HVAC
EQUIPMENT, DUCTWORK AND PIPING.
6. ANY REFRIGERANT EVACUATION AND RECOVERY
ASSOCIATED WITH THE DEMOLITION WORK IS THE
CONTRACTOR'S RESPONSIBILITY TO REMOVE FROM THE
SITE.
7. EXISTING EQUIPMENT LABELED WITH AN 'X' (I.E. XRTU) IS
EXISTING TO REMAIN.
8. (E) DENOTES EXISTING PIPING SYSTEM, I.E. (E) DCW.
16HVAC PLAN PLUMBING PLAN
NN
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
M
EC
H
AN
IC
AL
D
ET
AI
LS
M-501
DCW
DHW
COMBUSTION AIR
INTAKE AND EXHAUST
SHUT-OFF VALVE (TYP)
THERMOMETER
UNION (TYPICAL)
ASME RATED TEMP &
PRESSURE RELIEF
VALVE
PIPE TO FLOOR DRAIN
4" CONCRETE PAD
FINISHED FLOOR
DIRT LEG
UNION
GAS COCK
G
DHWR
EXPANSION
TANK
CHECK
VALVE (TYP)
DOMESTIC HOT WATER
RECIRC PUMP
SCALE: NOT TO SCALE
C4
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
M
EC
H
AN
IC
AL
S C
H
ED
U
LE
S
M-601
MD
EXISTING
PANEL "C"
REFRIGERATOR
PANEL "D":6
PANEL "D":10
PANEL "D":8
MICROWAVE
BELOW COUNTER
GFCI
ICE
MAKER
PANEL "D":4
PANEL "D":12
GARBAGE
DISPOSAL
DISHWASHER
GFCI
GFCI
GFCIGFCIGFCI
GFCI
GFCI
GFCI
GFCI
PANEL "D":14
PANEL "D":16
PANEL "D":18
PANEL "D":20
PANEL "D":24 PANEL "D":26 PANEL "D":28
PANEL "D":9
PANEL "D":7
J J
PANEL "D":21
PANEL "D":23
HOOD
HOOD
PANEL "D":13
GAS
OVEN
GAS
OVEN
PANEL "D":11
EF-1
WH-1
PANEL "D":15
J J
PANEL "D":1,3
PANEL "D":17,19
NEW
PANEL "D"
WALL
OVEN
WALL OVEN
PANEL "D":29
NAC
PANEL "D":27
PANEL "D":25
MD-1
FAN CONTROLLER
MULTI-PURPOSE
ROOM
STORAGE
MECHANICAL
PANEL "D":33
P-1
KITCHEN
MD
S
MD
L1 L1 L1
L1 L1 L1
L1 L1 L1
L1 L1 L1
L1 L1 L1
E1
A1
A1 A1 A1
A1
A1 A1 A1 D1
D1 D1 D1 D1 a a a a b b b b b b a
3b 3a
E1 c c c c c2
EXISTING
PANEL "C"
PANEL "D":2
J
PANEL "D":5
RETRACTABLE SCREEN
POWER CONNECTION
NEW
PANEL "D"
MULTI-PURPOSE
ROOM
KITCHEN
MECHANICAL
TO EXISTING
LIGHTING CIRCUIT
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
EL
EC
TR
IC
AL
P
LA
N
E-101
L.
R
AK
SI
N
L.
R
AK
SI
N W
. D
AV
ID
SO
N
M . D
O N
LE
Y
LIGHT FIXTURES:
A1 MFR: METALUX AP SERIES CWPLD LED
LAMPING: AS REQUIRED
L1 MFR: METALUX SKY RIDGE LED 2'x4' GRID CEILING
LAMPING: AS REQUIRED.
D1 MFR: LITHONIA LIGHTING 6" LDN6 LED DOWN LIGHT
LAMPING: AS REQUIRED
E1 MFR: THE EXIT LIGHT CO. COMBO2 LED EXIT + EM LIGHT
RED LETTERING
SELF-POWERED WITH NICAD BATTERY
SELF-DIAGNOSTIC
CEILING/PENDANT-MOUNTED
LUMINAIRE 1'x4'- LED
X
CEILING/PENDANT-MOUNTED
LUMINAIRE - LED
X
LEGEND:
EXISTING LIGHTING PANELBOARD
LIGHTING FIXTURE SUBSCRIPTS:
X - INDICATES FIXTURE TYPE PER
LIGHTING FIXTURE SCHEDULE
SINGLE-FACED WALL MOUNTED
COMBINATION EXIT AND
EMERGENCY LIGHT
FIELD VERIFY ALL MEASURMENTS FOR CONSTRUCTION AND
MATERIAL QUANTITIES.
FIELD VERIFY ALL MEASURMENTS FOR CONSTRUCTION AND
MATERIAL QUANTITIES.
KEYNOTES:
RELOCATE EXISTING RECEPTACLES PER NEW
ROOM DESIGNATION. MAINTAIN ASSOCIATED
EXISTING POWER CIRCUITS. COORDINATE
LOCATIONS WITH OWNER PRIOR TO RELOCATION.
NEW OWNER FURNISHED RETRACTABLE
PROJECTOR SCREEN.
RELOCATE EXISTING CEILING MOUNTED
PROJECTOR RECEPTACLE AND ASSOCIATED
POWER AND COMMUNICATIONS CIRCUITS. SEE
LIGHTING PLAN FOR NEW LOCATION.
RELOCATED PROJECTOR RECEPTACLE.
RELOCATE EXISTING BIG SCREEN TV SET AND
ASSOCIATED POWER AND COMMUNICATIONS
CIRCUITS PER OWNER DIRECTION.
RECEPTACLES LOCATED ABOVE COUNTER.
CONNECT NEW EXIT LIGHT TO EXISTING
NOT-SWITCHED LIGHTING CIRCUIT.
GENERAL NOTES:
1. IN MULTI-PURPOSE ROOM REPLACE ALL
EXISTING CEILING GRID MOUNTED LIGHT
FIXTURES WITH NEW FIXTURES.
RECONNECT NEW FIXTURES TO EXISTING
LIGHT CIRCUITS AND SWITCHES.
2. IN KITCHEN ROOM 101 SUSPEND LIGHT
FIXTURES 16 INCHES BELOW CEILING
UTILIZING AIRCRAFT CABLE.
3. IN MECHANICAL ROOM 104 REMOVE
EXISTING LIGHT FIXTURES TO ALLOW
CEILING REPLACEMENT. REINSTALL THE
LIGHT FIXTURES AFTER CEILING
REPLACEMENT IS COMPLETE.
DUPLEX RECEPTACLE, NEMA 5-20R
CEILING/RECESSED-MOUNTED
LUMINAIRE 2'x4'- LED
X
X
X
Y TOGGLE SWITCH
SUBSCRIPTS:
X - INDICATES TYPE
NONE - SINGLE POLE
3 - THREE-WAY
Y - INDICATES CONTROLLING LIGHT
QUADPLEX RECEPTACLE, NEMA 5-20R 6
Y
Y
Y - INDICATES CONTROLLING SWITCH
NEW LIGHTING PANELBOARD
HOME RUN TO PANEL, 2 #12, 1 #12G,
IN 3/4"C UNLESS OTHERWISE NOTED
POWER PLAN
LIGHTING PLAN
File details come from the government source that posted it.