Attachment_2_-_Design_Drawings3.pdf
PDF 2 MB Posted
- Attached to
- Chapel Kitchen Renovation Federal contract opportunity
- Solicitation number
- FA489719BA009
About this file
Part 3 of Attachment 2 Design Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_FA489719BA0090002.pdf | ||
| Amendment_FA489719BA0090001.pdf | ||
| Attachment_9_-_Asbestos_and_Lead_Inspection.pdf | ||
| Attachment_8_-_FSRM_PCR.pdf | ||
| Amendment_FA489719BA0090002.pdf | ||
| Attachment_7_-_Questions_and_Answers.pdf | ||
| Attachment_11_-_Addendum_1.pdf | ||
| Attachment_10_-_Utilities_Map.pdf | ||
| Attachment_3_-_PCR_Appendices2.pdf | ||
| Amendment_FA489719BA0090001.pdf | ||
| Attachment_1_-_Chapel_Kitchen_SOW.pdf | ||
| Attachment_5_-_Grand_View_Gate_Access_Information.pdf | ||
| Attachment_2_-_Design_Drawings2.pdf | ||
| Attachment_6_-_SFS_FORM_30.pdf | ||
| Attachment_2_-_Design_Drawings1.pdf | ||
| Attachment_3_-_PCR_Appendices1.pdf | ||
| Solicitation_-_FA489719BA009.pdf | ||
| Attachment_4_-_Wage_Determinations.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
FI
R
E
PR
O
TE
C
TI
O N
G
EN
ER
AL
N O
TE
S
F-001
A.
N
O W
KA
T.
F
R
EE
M
AN
M . D
O N
LE
Y
C
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
C O
D E
AN
AL
YS
IS
F-101
A.
N
O W
KA
T.
F
R
EE
M
AN
M . D
O N
LE
Y
AUTHORITY HAVING JURISDICTION: THE CONTRACTING OFFICER
PROJECT DESCRIPTION:
THE SCOPE OF WORK IS TO RENOVATE PORTIONS OF MOUNTAIN HOME
AFB (MHAFB) – CHAPEL. SCOPE OF WORK INCLUDES REMOVING EXISTING BREAK ROOM KITCHENETTE UPDATING FINISHES IN THE KITCHEN, STORAGE, MECHANICAL AND MULTIPURPOSE ROOM WITH NEW
DESIGN.
APPLICABLE CODES:
• UFC 1-200-01 DoD BUILDING CODE GENERAL BUILDING REQUIREMENTS (JUNE 20, 2016)
• UFC 3-410-01 HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS (CHANGE 4, NOVEMBER
2017)
• UFC 3-420-01 PLUMBING SYSTEMS (CHANGE 10, OCTOBER 26, 2015)
• UFC-3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES ( CHANGE 2, MARCH 25, 2018)
• UFC 3-601-02 OPERATION AND MAINTENANCE: INSPECTION, TESTING, AND MAINTENANCE OF FIRE
PROTECTION SYSTEMS (SEPTEMBER 8, 2010)
• UFC 4-010-01 MINIMUM ANTITERRORISM STANDARD (CHANGE 1, OCTOBER 1, 2013)
• UFC 4-021-01 MASS NOTIFICATION SYSTEMS (FEBRUARY 8, DRAFT 2017)
• 2015 INTERNATIONAL BUILDING CODE (ICC)
• 2015 INTERNATIONAL MECHANICAL CODE (ICC)
• 2017 NATIONAL ELECTRICAL CODE – NFPA 70
• 2015 INTERNATIONAL PLUMBING CODE (ICC)
• 2015 ABA ACCESSIBILITY STANDARD OF DOD FACILITIES
• 2018 LIFE SAFETY CODE – NFPA 101
CODE APPROACH:
FACILITIES, AS THEY EXIST, ARE REQUIRED (UFC 3-600-01, SECTION 34-1.1) TO MEET THE REQUIREMENTS OF NFPA 101, FOR EXISTING OCCUPANCIES. FACILITIES THAT DO NOT MEET THE
REQUIREMENTS OF NFPA 101 FOR EXISTING OCCUPANCIES MUST CONFORM TO ONE OF THE
FOLLOWING:
A. UPGRADE THE DEFICIENCY TO MEET THE EXISTING OCCUPANCY REQUIREMENTS; OR
ESTABLISH MANAGEMENT PROTOCOLS TO PROVIDE A LEVEL OF LIFE SAFETY EQUIVALENT TO
THAT REQUIRED BY NFPA 101 FOR EXISTING OCCUPANCIES, UNTIL AN UPGRADE PROJECT CAN BE
COMPLETED. MANAGEMENT PROTOCOLS MUST BE IN WRITING AND APPROVED BY THE AHJ.
B. IMPLEMENTATION OF THE DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS
STANDARD TO BRING ENTIRE INHABITED BUILDINGS INTO COMPLIANCE IS MANDATORY FOR ALL DOD BUILDING RENOVATIONS, MODIFICATIONS, REPAIRS, REVITALIZATIONS, AND RESTORATIONS
WHERE PROJECT COSTS EXCEED 50% OF THE PLANT REPLACEMENT VALUE OF THE EXISTING
BUILDING IN ACCORDANCE WITH UFC 3-701-01 BASED ON A BUILDING OF THE SAME SIZE EXCEPT
AS OTHERWISE STATED IN THESE STANDARDS. THE 50% COST IS EXCLUSIVE OF THE COSTS
IDENTIFIED TO MEET THESE STANDARDS (UFC 4-010-01). THE SCOPE OF WORK FOR THIS
PROJECT IS NOT EXPECTED TO EXCEED 50% OF THE BUILDING REPLACEMENT COST.
CODE COMPLIANCE SITE PLAN:
THE ENTIRE BUILDING PERIMETER MAINTAINS A MINIMUM OF 30 FEET OF OPEN SPACE AROUND THE BUILDING. THE FOOT PRINT OF THE BUILDING IS NOT INCREASED AS A PART OF THIS SCOPE OF WORK. THE BUILDING LOT AND ACCESS ROADS ARE MAINTAINED AS EXISTING CONDITIONS. CIVIL IMPROVEMENTS AS PART OF THIS SCOPE OF WORK. INCLUDE WATER SUPPLY TO NEW SPRINKLER
SYSTEM AND SIDEWALK TO NEW EGRESS DOOR.
OCCUPANCY CLASSIFICATION:
EXISTING ASSEMBLY (A-3), KITCHEN (A-2), SERVERY (A-2)) (NFPA 101 CH 13)
INCIDENTAL USE: STORAGE (NFPA 101 SECTIONS 6.1.14.1.3)
EXISTING BUSINESS (OFFICES)
TYPE OF CONSTRUCTION: TYPE (V-B)
ALLOWABLE HEIGHT/STORIES: 40 FT / 1 STORY (TABLES 504.3 AND 504.4)
ACTUAL HEIGHT/STORIES: 20 FT /1 STORY
A-2 AND A-3 OCCUPANCY:
ALLOWABLE BUILDING AREA (PER STORY) (TABLE 506.2) 6,000 FT2
ALLOWABLE FRONTAGE INCREASE (506.3) 1.75 X 6,000 FT2 = 10,500 FT2
ACTUAL TOTAL BUILDING AREA: 12,920 FT2
EXISTING NON-CONFORMING CONDITION. BUILDING WILL BE CODE COMPLIANT WHEN
BUILDING IS PROTECTED THROUGHOUT WITH A FIRE SPRINKLER SYSTEM.
ACTIVE FIRE RESISTANCE:
IDENTIFY FIRE RATED WALLS IBC §703.7 REQUIRES FIRE RESISTIVE WALLS TO BE
IDENTIFIED WITH SIGNS OR STENCILING.
STRUCTURAL FRAME 0-HOUR (IBC TABLE 601)
(COLUMNS, BEAMS & GIRDERS
CONNECTING TO COLUMNS,
BEARING WALLS & DIAGONALS
CARRYING GRAVITY LOADS)
INTERIOR AND EXTERIOR BEARING 0-HOUR (IBC TABLE 601) WALLS
INTERIOR WALLS SEPARATING
SPRINKLERED TO NON-SPRINKLERED 2-HOUR (WALLS AND CEILING ASSEMBLIES)
EXISTING SEPARATION CORRIDOR TO 1-HOUR
MULTIPURPOSE ROOM
EXTERIOR WALL 0-HOUR; FIRE SEPARATION DISTANCE GREATER THAN 10
FEET. (IBC TABLE 602)
EXTERIOR NONBEARING WALLS 0-HOUR CONSTRUCTION (IBC TABLE 602)
ROOF CONSTRUCTION 0-HOUR (IBC TABLE 601)
ROOF COVERING CLASS C (IBC TABLE 1505.4)
FLOOR CONSTRUCTION 0-HOUR (IBC TABLE 601)
EXTERIOR NONBEARING WALLS 0-HOUR CONSTRUCTION (IBC TABLE 602)
PERMANENT PARTITIONS 0-HOUR (IBC TABLE 601)
PROVIDE PROTECTION OF HAZARDS AS REQUIRED BY NFPA-101 8.7.
CORRIDORS 0-HOUR (NFPA 101 §13.3.6)
STORAGE ROOMS > 100 SQ. FT. 0-HOUR SMOKE PARTITION (NFPA 101 §8.7)
ELECTRICAL ROOM 0-HOUR SMOKE PARTITION (ASSUME NO
TRANSFORMERS)
WALL PENETRATIONS F RATING EQUAL TO THE RATING IF THE WALL
PENETRATED (IBC §714.3)
FLOOR PENETRATIONS F RATING: 0-HOURS AND T RATING: 0-HOURS (IBC §714.4)
CEILING PENETRATIONS F RATING EQUAL TO THE RATING IF THE CEILING
PENETRATED (IBC §714) AND PER UL-I503 CEILING
ASSEMBLY LISTING REQUIREMENTS
INTERIOR FINISH:
WALL AND CEILING FINISH (NFPA 101 CH.10): SMOKE DEVELOPED OF 450 OF LESS, AND,
INSIDE CORRIDORS CLASS A OR B
INSIDE ROOMS CLASS A, B OR C
FLOOR FINISH DOC FF 1-70 “PILL TEST” (FEDERALLY MANDATED)
PLENUMS (IMC §602) CLASS A AND SMOKE DEVELOPED OF 50 OF LESS.
ACTIVE FIRE PROTECTION:
AUTOMATIC SPRINKLER SYSTEM REQUIRED FOR RENOVATED KITCHEN AREA. NO FIRE
SPRINKLERS ABOVE 2-HOUR CEILING ASSEMBLY
HYDRANT FLOW TEST DATA:
HYDRANT B-98 SEPTEMBER 19, 2018: 4074 GPM AT 20 PSI RESIDUAL
REQUIRED FIRE FLOW 3,000 GPM FOR 3-HOURS (NFPA 1, TABLE 18.4.5.2.1 WITH
SPRINKLER REDUCTION PER §18.4.5.3.2)
STANDPIPES NOT REQUIRED
FIRE ALARM SYSTEM VOICE EVAC REQUIRED (NFPA 101 §13.3.4.1.1 AND 13.3.4.3)
MASS NOTIFICATION SYSTEM NOT REQUIRED FOR LOW OCCUPANCY BUILDING NOT
ROUTINELY OCCUPIED (UFC 4-010-01)
SMOKE DETECTION NOT REQUIRED (NFPA 101 §13.3.4.2.1)
SMOKE DETECTOR PROVIDED ABOVE NEW NAC PANEL
PER NFPA 72.
FIRE EXTINGUISHERS NOT REQUIRED (NFPA 101 §13.3.5, UFC 3-600-01 C2 §19-7.1)
*** NOTE: FOR SYSTEMS REQUIRING UPGRADES, THE UPGRADES ARE ONLY REQUIRED WITHIN THE
SCOPE OF WORK. AREAS OUTSIDE SCOPE OF WORK WILL BE ADDRESSED ON FUTURE
RENOVATIONS/MODIFICATIONS ***
EMERGENCY POWER:
EXIT SIGNS REQUIRED (NFPA 101 §7.10.5.1)
EGRESS ILLUMINATION REQUIRED (NFPA 101 §13.2.9.1)
MINIMUM HEIGHT:
CORRIDORS AND ROOMS: 90 IN. (NFPA 101 §7.1.5.1)
DOOR 80 IN. (NFPA 101 §7.2.1.2.1.1(6))
EXITING:
OCCUPANT LOAD FACTORS (NFPA 101 TABLE 7.3.1.2) (SQUARE FEET PER PERSON)
OFFICE AREAS 100 (GROSS)
ASSEMBLY
(TABLES AND CHAIRS) 15 (NET)
(STANDING ROOM) 5 (NET)
KITCHENS 200 (GROSS)
MECHANICAL/STORAGE ROOMS 500 (GROSS)
DOOR HARDWARE:
PANIC HARDWARE
• REQUIRED FOR ASSEMBLY OCCUPANT LOADS GREATER THAN 100
• REQUIRED ON ALL GROUND FLOOR EXIT DOORS.
PERMITTED EXIT DOOR HARDWARE PANIC HARDWARE
DELAYED EGRESS LOCKS NOT IN SCOPE
ACCESS-CONTROLLED EGRESS DOORS NOT IN SCOPE
LOCKS ON THE MAIN DOOR NOT IN SCOPE
DOOR SWING:
IN THE DIRECTION OF EGRESS IF SERVING AREA WITH 50 OR MORE (NFPA 101 §7.2.1.4.2)
DISTANCES (EXISTING BUILDINGS):
CORRIDOR DEAD ENDS 20 FEET IN ASSEMBLY OCCUPANCIES WITH GREATER THAN 50
OCCUPANTS (NFPA 101 TABLE A.7.6)
TRAVEL DISTANCE 200 FEET IN NON-SPRINKLERED ASSEMBLY OCCUPANCIES
(NFPA 101 TABLE A.7.6)
COMMON PATH OF TRAVEL 75 FEET IN NON-SPRINKLERED ASSEMBLY OCCUPANCIES WITH
GREATER THAN 50 OCCUPANTS (NFPA 101 TABLE A.7.6)
EXIT WIDTHS:
DOORS 0.2 IN PER PERSON (NFPA 101 TABLE 7.3.3.1)
MINIMUM DOOR WIDTH 32 IN CLEAR (NFPA 101 §7.2.1.3.2 (1))
MINIMUM CORRIDOR WIDTH OCCUPANT LOAD / # EXITS (NFPA 101 §7.3.3.3)
*** SEE LIFE SAFETY PLAN FOR ACTUAL OCCUPANT LOAD AND PROVIDED EXIT CAPACITIES ***
NUMBER OF EXITS FROM SPACES:
ASSEMBLY/BUSINESS ONE EXIT IS PERMITTED IF THE COMMON PATH OF TRAVEL IS
NOT EXCEEDED.
TWO EXITS ARE REQUITED FROM EACH SPACE WHEN THE
COMMON PATH OF TRAVEL IS EXCEEDED.
THREE EXITS ARE REQUIRED WHEN THE POPULATION IS > 500
PEOPLE (NFPA 101 §7.4.1.2)
EXIT SEPARATION SEPARATED BY NOT LESS THAN ONE-HALF THE DIAGONAL OF
THE BUILDING OR AREA SERVED (NFPA 101 §7.5.1.3.3) WHEN
NOT EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER
SYSTEM.
EXITS AND CONTINUITY THE REQUIRED NUMBER OF EXITS AND EXIT ACCESS SHALL BE
MAINTAINED UNTIL ARRIVAL AT GRADE AND A PUBLIC WAY.
(NFPA 101 §7.4.1.4)
NUMBER OF EXITS 2 EXITS FROM EACH STORY (NFPA 101 §13.2.4.1)
SIDEWALK REQUIRED FROM EXTERIOR EXIT DOORS TO THE
PUBLIC WAY.
*** SEE LIFE SAFETY PLAN FOR ACTUAL EXIT LOCATIONS AND ARRANGEMENT ***
LIGHTS:
EXIT SIGNS REQUIRED IN SPACES WHERE TWO EXIT PATHS ARE REQUIRED
(NFPA 101 §7.10.1)
EGRESS ILLUMINATION 1 FOOT-CANDLE ON NORMAL POWER THROUGHOUT (NFPA 101
§7.8.1.3 (2))
EGRESS ILLUMINATION 1 FOOT-CANDLE ON EMERGENCY POWER IN SPACES REQUIRED
TO HAVE 2 WAYS OUT, CORRIDORS, AND EXTERIOR LANDINGS
(NFPA 101 §13.2.9.1(3) AND 7.9.2.1)
MEANS OF EGRESS FOR THE DISABLED:
AREAS OF REFUGE SHALL MEET NFPA §7.2.12.1.1 (NFPA 101 SECTION 13.2.2.12).
ACCESSIBLE MEANS OF EGRESS:
ACCESSIBLE MEANS OF EGRESS IN THIS BUILDING HAVE THE FOLLOWING REQUIREMENTS:
• SMOKE SEPARATION INTO TWO COMPARTMENTS NOT REQUIRED
• TWO ACCESSIBLE MEANS OF EGRESS REQUIRED
Wx
W x
W x
W x
W x
W x
W x
W x
SHED
SHED
SHED
GUNFIGHTER AVENUE
FIR STREET
GUNFIGHTER AVENUE
GUNFIGHTER AVENUE
DESERT STREET
W x
W x
W x
W x
Wx
Wx
Wx
W x
Wx
Wx
Wx
W x
W x
Wx
EXISTING FIRE
HYDRANT
EXISTING FIRE
HYDRANT
EXISTING FIRE
HYDRANT
FIRE RISER LOCATION
FDC
POST INDICATOR VALVE (PIV)
30.00'
30.00'
.00
.00
UFC-3-600-1, SECTION 9-3.5.9.4 FIRE HYDRANT
DISTANCE TO FIRE DEPARTMENT CONNECTION
(216FT) EXCEEDS 150FT MAXIMUM ALLOWABLE
DISTANCE.
UFC - 3-600-1 SECTION 9-3.5.8.2. ALL PARTS OF
THE FACILITY ARE WITH IN 350 FEET OF THE
FIRE HYDRANT. EXISTING HOSE COVERAGE IS
264 FEET.
CHAPEL BLDG NO 2606
CHAPEL ANNEX
BLDG NO 1505
FIRE DEPARTMENT
MAIN ENTRANCE
PIV
30 FEET FIRE
SEPARATION
DISTANCE
EXISTING FIRE
HYDRANTEXISTING FIRE ALARM PANEL
DESERT STREET
GUNFIG
HTER AVENUE
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
C O
D E
C O
M
PL
IA
N
C E
SI
TE
P
LA
N
F-102
A.
N
O W
KA
T.
F
R
EE
M
AN
M . D
O N
LE
Y
CODE COMPLIANCE SITE PLAN
1. SITE CODE COMPLIANCE PLAN PROVIDED AS
REQUIRED PER UFC 3-600-01 - 1-7.2.4.2.
FIRE PROTECTION NOTES:
40'40' 0
SCALE: 1" = 40'-0"
STORAGE
S-1
.2 32"
TRAVEL DISTANCE = 55'-2"
TRAVEL DISTANCE = 92'-4"
ENLARGE OPENING
TO PERMIT EGRESS -
MINIMUM 44"
2-HOUR FIRE BARRIER. FIRE SHUTTER (2-HOUR)
INFILL WALL OPENING
(1 HOUR)
EXIT SEPARATIO
N: 12 O
VERALL DIAG
O
NAL = 32'-6"
65'-0"
MULTI-PURPOSE
ROOM
KITCHEN
STORAGE
MECHANICAL
.2 64"
S S S S S S S S S S S S S S S S S S S S S
ASSEMBLY
A-2
ASSEMBLY
A-3
11315
.2 32"
S S
S S
S S
S S
S S
S S S S S S S
S S
S S
S S
S S
S S
SSSSS
INFILL WALL OPENING
(1 HOUR)
2-HOUR CEILING
ASSEMBLY (HATCHED
AREA ONLY)
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
LI
FE
S
AF
ET
Y
PL
AN
F-103
A.
N
O W
KA
T.
F
R
EE
M
AN
M . D
O N
LE
Y
LIFE SAFETY FLOOR PLAN
XXXXXXXX
XXX
XXXX
XXX
XXX
XXX
XXX
XXX
SPACE TYPE,
OCCUPANCY
OCCUPANCY LOAD
OCCUPANT CAPACITY
FACTOR, SF/PERSON
NET AREA SF
CLASSIFICATION
EXIT DOOR NUMBER
DOOR CAPACITY (PEOPLE)
EGRESS CAPACITY FACTOR
CLEAR WIDTH
OPENING
LIMITING FACTOR
EMERGENCY EXIT SIGNS
EXIT TRAVEL = X'-X"
EXIT TRAVEL
DISTANCE
EXIT DISCHARGE ARROW
EXIT DISCHARGE
S S S S S
1. MAINTAIN 36" CLEAR AT ALL EGRESS DOORS.
LIFE SAFETY NOTE:
8'0 4' 16'
FIRE SPRINKLER RISER
LOCATION. SEE DETAIL 1/F-501 .
SEE CIVIL FOR CONTINUATION
SPRINKLER SYSTEM SCHEDULE*
HAZARD
CLASS
MIN. SPK. SYS.
HYDR. DESIGN
AREA (SQ.-FT)
HOSE
(GPM)
N/AN/A
2500.20
N/AN/A
WET
NON
SPRINKLERED
ORDINARY
AREA MIN. DENSITY
(GPM/SQ.-FT)
ALL AREAS
THAT ARE NOT
HATCHED
SYSTEM
TYPE
(MIN.)
DURATION
N/A
* BASED ON UFC 3-600-01 TABLE 9-3 & 9-4.
2-HOUR FIRE RATED CEILING
ASSEMBLY AT KITCHEN 101
AND MECHANICAL 104. NO FIRE
SPRINKLER PROTECTION
REQUIRED IN COMBUSTIBLE
SLOPED CEILING ATTIC.
MULTI-PURPOSE
ROOM
KITCHEN
STORAGE
MECHANICAL
ACCESS HATCH TO COMBUSTIBLE CONCEALED
FLOOR STRUCTURE BELOW MECHANICAL ROOM
AND STAIRS AND RAISED LANDING. PROVIDE
WITH WET TYPE SPRINKLER SYSTEM IN
COMBUSTIBLE CONCEALED AREAS.
60NAC
FIRE SPRINKLER RISER AND
MAINTENANCE ACCESS
WET FIRE SPRINKLER SYSTEM
TO BE SIZED FOR FUTURE
EXTENSION THROUGH OUT
MULTI-PUROSE ROOM 102. CAP
FULL SIZE MAIN FOR FUTURE
EXTENSION.
PROVIDE FIRE ALARM CONTROL OF
24V AUTOMATIC GAS SHUT OFF
VALVE SHOWN ON SHEET M-101.
NEW FIRE ALARM POWER
SUPPLY TO PROVIDE POWER
FOR DOOR HOLDERS AND
NOTIFICATION DEVICES.
PROVIDE NEW SMOKE
DETECTOR ABOVE PANEL. ALL
NEW PULL STATIONS, SMOKE
DETECTORS, MODULES, ETC
ARE REQUIRED TO BE SILENT
KNIGHT BRAND TO BE
COMPATIBLE WITH THE
EXISTING ADDRESSABLE FACP.
COORDINATE AND MAINTAIN
ROOM FUTURE DRY PIPE
SPRINKLER SYSTEM AND
NITROGEN GENERATOR WITH
MAINTENANCE ACCESS
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
O
FI
R
E
PR
O
TE
C
TI
O N
P
LA
N
F-104
A.
N
O W
KA
T.
F
R
EE
M
AN
M . D
O N
LE
Y
FIRE PROTECTION FLOOR PLAN
8'0 4' 16'
PIPE SADDLE
PROVIDE CLAMP
WITH SUPPORT
LENGTH & THREADS TO ALLOW
MINIMUM AND MAXIMUM
DIMENSIONS SHOWN IN TABLE.
USE STRAIGHT THREADS.
SCHEDULE 40 PIPE
THREADED 150 LB
REDUCING FLANGE
(4) EPOXY ADHESIVE
ANCHORS.
TOP BEAM CLAMP
OR UL LISTED PURLIN
CLAMP
ALL THREAD ROD
RETAINING STRAP
SEISMIC
SPRINKLER SYSTEM SHALL BE SEISMIC BRACED IN
ACCORDANCE WITH NFPA 13, 2013 REQUIREMENTS
ROD FOR
SEISMIC
RESTRAINT
UL LISTED
PIPE
HANGER
RING
OUTSIDE WALL
1" BALL VALVE
GALV. 1" 45° ELBOW
" M
AX
GRADE
FINISHED
FLOOR
BUSHING WITH 1/2" SMOOTH BORE
CORROSION RESISTANT OUTLET
EQUIVALENT TO ONE SPRINKLER
WATERPROOF SLEEVE THRU
WALL (CAULK ALL AROUND)
SPLASH BLOCK
M
AX
UL LISTED PIPE
HANGER RING
DRY SYSTEM
AUXILIARY DRAIN
OUTSIDE WALL
GALV. 1" 45° ELBOW 84
" M
AX
GRADE
BUSHING WITH 1/2" SMOOTH BORE
CORROSION RESISTANT OUTLET
EQUIVALENT TO ONE SPRINKLER
WATERPROOF SLEEVE THRU WALL
(CAULK ALL AROUND)
SPLASH BLOCK
M
AX
M
AX
FINISHED
FLOOR
1" BALL VALVE (TYP.)
FI
R
E
PR
O
TE
C
TI
O N
D
ET
AI
LS
F-501
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T D
AT
E:
D
AT
E D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
C
ES
/C
EN
M O
U N
TA
IN
H O
M E
AI
R
F O
R C
E
BA
SE
141312111098
7654321
AN
SI
D
JA
N U
AR
Y
AS
N
O
TE
D
H D
R E ng in ee rin g, In c.
E
PA
R
KC
EN
TE
R B
LV
D
#1
BO
IS
E, ID
(2
) 3
-7
FA
-1
4- D
-3
/2
7/
C H
AP
EL
K
IT
C H
EN
R
EN
O
VA
TI
O N
, F
AC
IL
IT
Y
M
O U
N
TA
IN
H
O M
E
AI
R F
O R
C E
BA
SE
ID
AH
File details come from the government source that posted it.