Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report
Work Order Scope of Work:
Renovate the building
Building Number: 16
Inspection Date: 3/4/2016
Nellis Work Order: 27298
Macrotec Job Number: 16539
The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building
Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.
Introduction:
Report Limitations:
Dustin R. McAllister
Nevada-OSHA Certified Asbestos Abatement Consultant
License # IPM0961
US EPA Lead Risk Assessor
Certificate # NV-R-16781-2
9724 Mild Weather Ct., Las Vegas, NV 89148 Phone: (702) 338-8213 Fax: (702) 629-5677
Macrotec Consulting, LLC.
Appendix A - Asbestos Assessment
Macrotec Job #16539 - Bldg. 16
The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.
1 Wall Substrate (Drywall & Mud) - Wallpapered This material is located on various walls throughout the building.
No Asbestos Detected
None DetectedInterior - Open Area - Adj. SW Exterior DoorAB1
None DetectedInterior - Open Area - Adj. Door to Room 1AB2
2 Wall Substrate (Drywall & Mud) - Textured This material is located on various walls throughout the building.
No Asbestos Detected
None DetectedInterior - Room 5 - Adj. doorAB3
None DetectedInterior - Room 2 - Adj. doorAB4
None DetectedInterior - Open Area - Adj. Door to Room 9AB5
3 Spray-on Wall Texture - This material is located atop various walls throughout the building.
No Asbestos Detected
None DetectedInterior - Room 7 - Adj. Door to Open AreaAB6
None DetectedInterior - Room 4 - S wallAB7
None DetectedInterior - Open Area - E wallAB8
None DetectedInterior - Room 9 - SW cornerAB9
None DetectedInterior - Room 3 - Adj. doorAB10
4 Carpet & Base Cove Mastic - Yellow This material is located on the floor below the carpet throughout the building. (except in bathrooms and break room).
No Asbestos Detected
None DetectedInterior - Open Area - Adj. SW Exterior DoorAB11
5 Floor Fill - White This material is located on the floor below the carpet throughout the building. (except in bathrooms and break room).
No Asbestos Detected
None DetectedInterior - Open Area - Adj. Door to Break RoomAB12
6 2X2 Ceiling Tile - This material is located on the ceiling throughout the building.
No Asbestos Detected
None DetectedInterior - Open Area - S sideAB13
Asbestos Survey
WO #27298 - Bldg. 16
Macrotec Job #16539
Appendix A
Macrotec Job #16539 - Bldg. 16
7 Wallpaper & Mastic - Gray This material is located atop various walls throughout the building.
No Asbestos Detected
None DetectedInterior - Open Area - NW cornerAB14
8 Concrete - Gray This material is located on the exterior sidewalks.
No Asbestos Detected
None DetectedExterior - - N sideAB15
9 Brick - This material is located on the exterior walls.
No Asbestos Detected
None DetectedExterior - - N sideAB16
10 Mortar - On Brick This material is located atop the exterior walls.
No Asbestos Detected
None DetectedExterior - - N sideAB17
11 Pipe Wrap - Black Tar/Foam to AC Unit This material is located on the on the pipe to the AC unit adjacent the mechanical room.
No Asbestos Detected
None DetectedExterior - - Adj. Mech. RoomAB18
12 HVAC Duct Wrap - This material is located on the HVAC duct in the mechanical room and assumed to be in the interior of the building.
No Asbestos Detected
None DetectedInterior - Mech Room - W sideAB19
13 HVAC Duct Mud - Gray - On Duct Seams This material is located on the HVAC duct seams in the mechanical room and assumed to be in the interior of the building.
No Asbestos Detected
None DetectedInterior - Mech Room - W sideAB20
Asbestos Survey
WO #27298 - Bldg. 16
Macrotec Consulting, LLC.
Appendix B - Lead Assessment
Macrotec Job #16539 - Bldg. 16
Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix D lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.
Lead Paint Survey
WO #27298 - Bldg. 16
Asbestos and Lead Based Paint Inspection
Nellis AFB—Building 16
Macrotec Project # 16539
Appendix C
Sample Location Diagram
AB1
The walls in the interior and exterior above were tested for lead based paint with a XRF Analyzer. See results page for materials & locations.
AB2
AB3
AB4
AB5
AB6
5 6 7
Break Room
Men’s Room
Woman’s Room
Open Room
Mech. Room
AB7
AB8
AB9
AB10
AB11
AB12
AB13
AB14
AB15AB16
AB17
AB18
AB19
AB20
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
2*.(1-3(+1/+ _ MJ\4 2*.(1-3(+1/-
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
16539
WO #26843- Bldg. 16
160307I
3/7/2016 3/7/2016 3/9/2016
B.TrimmerJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB:
10% Cellulose 90%AB1- Drywall / White Powder, Brown Fibers NAD1A
100%AB1- Mud / White Powder NAD1B
10% Cellulose 90%AB2- Drywall / White Powder, Brown Fibers NAD2A
100%AB2-Mud / White Powder NAD2B
10% Cellulose 90%AB3-Drywall / White Powder, Brown Fibers NAD3A
100%AB3- Mud / White Powder NAD3B
10% Cellulose 90%AB4- Drywall / White Powder, Brown Fibers NAD4A
100%AB4- Mud / White Powder NAD4B
5% Cellulose 95%AB5- Drywall / White Powder, Brown Fibers NAD5A
100%AB5- Mud / White Powder NAD5B
Wednesday, March 09, 2016 Page 1 of 3
JQ\_[Ub QaU Q]Q[hiUT Y] QSS^aTQ]SU fYcX jB]cUaY\ EUcX^T V^a cXU =UcUa\Y]QcY^] ^V 9bRUbc^b Y] ;d[Z B]bd[QcY^] JQ\_[Ubk( >H9 2,,+E0)4.),.,( =US* -54.
and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound][
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director Yuedong Fang, Senior Geologist
13509 East Boundary Road, Suite B, Midlothian, VA 23112
2*.(1-3(+1/+ _ MJ\4 2*.(1-3(+1/-
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
16539
WO #26843- Bldg. 16
160307I
3/7/2016 3/7/2016 3/9/2016
B.TrimmerJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB:
2% Cellulose 98%AB6 / White Powder NAD6
2% Cellulose 98%AB7 / White Powder NAD7
100%AB8 / White Powder NAD8
100%AB9 / White Powder NAD9
100%AB10 / White Powder NAD10
5% Fiberglass
5% Cellulose 90%AB11 / Yellow Adhesive NAD11
2% Cellulose 98%AB12 / White Powder NAD12
20% Fiberglass
70% Cellulose 10%AB13 / Gray Fibers NAD13
95% Synthetic 5%AB14 / White and Gray Fibers NAD14
2% Cellulose 98%AB15 / Gray Cement NAD15
Wednesday, March 09, 2016 Page 2 of 3
JQ\_[Ub QaU Q]Q[hiUT Y] QSS^aTQ]SU fYcX jB]cUaY\ EUcX^T V^a cXU =UcUa\Y]QcY^] ^V 9bRUbc^b Y] ;d[Z B]bd[QcY^] JQ\_[Ubk( >H9 2,,+E0)4.),.,( =US* -54.
and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound][
Reviewed By Authorized Signatory:
13509 East Boundary Road, Suite B, Midlothian, VA 23112
2*.(1-3(+1/+ _ MJ\4 2*.(1-3(+1/-
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
16539
WO #26843- Bldg. 16
160307I
3/7/2016 3/7/2016 3/9/2016
B.TrimmerJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB:
2% Cellulose 98%AB16 / Brown Granular NAD16
2% Cellulose 98%AB17 / Red Granular NAD17
100%AB18 / Black Foam-like NAD18
15% Fiberglass
70% Cellulose 15%AB19 / Tan Fibers, Foil NAD19
5% Cellulose 95%AB20 / Gray Adhesive NAD20
Total Samples/Layers Analyzed: 25
Wednesday, March 09, 2016 Page 3 of 3
JQ\_[Ub QaU Q]Q[hiUT Y] QSS^aTQ]SU fYcX jB]cUaY\ EUcX^T V^a cXU =UcUa\Y]QcY^] ^V 9bRUbc^b Y] ;d[Z B]bd[QcY^] JQ\_[Ubk( >H9 2,,+E0)4.),.,( =US* -54.
and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound][
Reviewed By Authorized Signatory:
XRF Data Table
Time Duration Component Substrate Side Color Condition Building Room Results Depth PbC PbC Error PbL PbL Error PbK PbK Error
3/4/16 10:40 1.06 Cal Orange Positive 1.08 1.5 0.4 1.5 0.4 < LOD 3.75
3/4/16 10:41 0.83 Cal Orange Positive 1.29 1.9 0.9 1.9 0.9 < LOD 5.25
3/4/16 10:41 1.06 Cal White Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.77
3/4/16 10:42 2.59 Wall Drywall A White Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.95
3/4/16 10:42 1.6 Wall Drywall B White Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.38
3/4/16 10:43 1.9 Wall Drywall C Gray Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.05
3/4/16 10:44 1.07 Wall Drywall D Gray Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.85
3/4/16 10:45 5 Wall Drywall A White Intact 16 2 Negative 5.19 < LOD 0.05 < LOD 0.05 < LOD 0.9
3/4/16 10:45 1.82 Wall Drywall B White Intact 16 2 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.1
3/4/16 10:46 1.68 Wall Drywall C White Intact 16 2 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.29
3/4/16 10:46 1.14 Wall Drywall D Gray Intact 16 2 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.81
3/4/16 10:46 1.06 Door Wood B Brown Intact 16 2 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.55
3/4/16 10:47 1.06 Doorframe Metal B Gray Intact 16 2 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.35
3/4/16 10:48 2.74 Wall Drywall A White Intact 16 3 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.8
3/4/16 10:48 2.58 Wall Drywall B White Intact 16 3 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.95
3/4/16 10:48 1.75 Wall Drywall C White Intact 16 3 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.14
3/4/16 10:49 1.75 Wall Drywall D Gray Intact 16 3 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.04
3/4/16 10:50 1.06 Door Wood B Brown Intact 16 3 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.62
3/4/16 10:50 1.06 Doorframe Metal B Gray Intact 16 3 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.92
3/4/16 10:51 3.04 Wall Drywall A White Intact 16 4 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.2
3/4/16 10:51 1.37 Wall Drywall C White Intact 16 4 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.43
3/4/16 10:52 1.9 Wall Drywall D Gray Intact 16 4 Negative 1.69 < LOD 0.04 < LOD 0.04 < LOD 2.08
3/4/16 10:52 0.3 Wall Drywall A Gray Intact 16 7 Null 10 < LOD 0.55 < LOD 0.55 < LOD 7.35
3/4/16 10:53 1.6 Wall Drywall A Gray Intact 16 7 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.24
3/4/16 10:53 1.37 Wall Drywall B White Intact 16 7 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.52
3/4/16 10:53 1.67 Wall Drywall C Gray Intact 16 7 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.14
3/4/16 10:54 0.91 Wall Drywall C White Intact 16 9 Null 1 < LOD 0.03 < LOD 0.03 < LOD 4.35
3/4/16 10:55 1.37 Wall Drywall B Gray Intact 16 9 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.22
3/4/16 10:55 1.75 Wall Drywall C White Intact 16 9 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.24
3/4/16 10:56 1.06 Door Wood D Brown Intact 16 9 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.7
3/4/16 10:56 1.06 Doorframe Metal D Gray Intact 16 9 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.35
3/4/16 10:57 1.06 Doorframe Metal A Gray Intact 16 7 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.3
3/4/16 10:57 1.06 Door Wood A Brown Intact 16 7 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.85
3/4/16 10:58 1.06 Door Wood A Brown Intact 16 6 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.7
3/4/16 10:58 1.06 Doorframe Metal A Gray Intact 16 6 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.06
3/4/16 10:58 1.06 Doorframe Metal A Gray Intact 16 4 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.33
3/4/16 10:59 1.06 Door Wood A Brown Intact 16 4 Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.25
3/4/16 10:59 1.07 Door Metal C Brown Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.98
3/4/16 10:59 1.07 Doorframe Metal C Brown Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.1
3/4/16 11:00 1.82 Doorframe Metal A Black Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.38
Nellis Air Force Base Building 16 Macrotec Job #16539 1
XRF Data Table
Time Duration Component Substrate Side Color Condition Building Room Results Depth PbC PbC Error PbL PbL Error PbK PbK Error
3/4/16 11:01 3.04 Door Metal A Black Intact 16 Open Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.46
3/4/16 11:10 0.23 Wall Brick A Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 18.9
3/4/16 11:10 3.04 Wall Brick A Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.5
3/4/16 11:11 1.06 Handrail Metal A Brown Intact 16 Exterior Negative 2.23 < LOD 0.06 < LOD 0.06 < LOD 4.72
3/4/16 11:11 1.06 Handrail Metal A Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.65
3/4/16 11:11 1.07 Handrail Metal A Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.65
3/4/16 11:12 1.06 Door Metal D Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.05
3/4/16 11:12 1.06 Doorframe Metal D Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.03
3/4/16 11:13 3.27 Wall Brick B Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.35
3/4/16 11:14 1.06 Door Metal B Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.14
3/4/16 11:14 1.22 Doorframe Metal B Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.66
3/4/16 11:15 1.06 AC Metal B Beige Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.85
3/4/16 11:15 1.06 AC Metal B Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.37
3/4/16 11:22 0.23 Cal Yellow Positive 1.41 < LOD 4.8 < LOD 4.8 < LOD 16.65
3/4/16 11:22 0.23 Cal Yellow Positive 1.52 < LOD 5.85 < LOD 5.85 < LOD 15.75
3/4/16 11:22 0.31 Cal Yellow Positive 1.12 2.8 1.7 2.8 1.7 < LOD 11.4
Nellis Air Force Base Building 16 Macrotec Job #16539 2
DISAPPROVED
DOUGLAS C. FITZPATRICK, RA, GS-14
Deputy Base Civil Engineer
28. NAME AND GRADE (Please Type or Print)
99 CES
1. FROM (Organization)
CENMP 20160301
3. DATE OF REQUEST 4. WORK REQUEST NO. (For BCE Use)
Danilo T. Ocampo
DSN 682-8437
5. NAME AND PHONE NO. OF REQUESTER
20160330
6. REQUIRED COMPLETION DATE
Bldg 16
Sampling and testing of materials for asbestos and lead-based paint (LBP) in support of SRM project RKMF 16-0062, Repair Courtroom, Bldg 16, Nellis AFB (Work Order # 26843)
8. DESCRIPTION OF WORK TO BE ACCOMPLISHED (Include Sketch or Plan, when appropriate)
30. DATE
Building 16 is being reconfigured to accommodate a courtroom. Project scope includes demoliton of walls, ceiling, and floor covering, replacement of existing HVAC system. Installation of new partition walls with communications and power drops.
Removal and reinstallation of existing lighting, fire alarm and mass notification systems. An asbestos and LBP aurvey is required to ensure that hazardous materials, if present, are identified and properly abated.
9. BRIEF JUSTIFICATION FOR WORK TO BE ACCOMPLISHED (Not required for maintenance and repair)
Will be paid using Engineering Flight's GPC
10. DONATED RESOURCES
DANILO T. OCAMPO
Project Engineer
11. NAME OF REQUESTER
GS-12
12. GRADE OF REQUESTER
27. REMARKS
SECTION IV - APPROVING AUTHORITY
BASE CIVIL ENGINEER WORK REQUEST
(See Reverse for Instructions) OMB No. 0704-0188
Form Approved
Public reporting burden for this collection of information is estimated to average .3 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington
Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project 0704-0188, Washington DC 20503. Please DO NOT RETURN your form to either of these addresses.
Send your completed form to HQ AFESC/DEMG.
SECTION I - TO BE COMPLETED BY REQUESTER
SYMBOL
2. OFFICE
7. BUILDING, FACILITY OR STREET ADDRESS
WHERE WORK IS TO BE ACCOMPLISHED
AF IMT 332, 19910101, V4 PREVIOUS EDITION IS OBSOLETE. MASTER FILE COPY
ASSESSMENT (AFR 19-2)
23.
THERE IS NO NEED FOR AN ENVIRONMENTAL
FUNDS LABOR MATERIAL CONTRACT BY REQUESTER NONE
13. SIGNATURE OF REQUESTER (See Reverse of Form)
SECTION II - FOR BASE CIVIL ENGINEER USE
SECTION III - COMPLETE ONLY IF WORK IS TO BE ACCOMPLISHED BY WORK ORDER
IN-SERVICE SELF-HELP CONTRACT SABER
EMERGENCY URGENT ROUTINE SELF-HELP
BRIEFING REQUIRED ADEQUATE COORDINATION INSPECTION REQUIRED
M/C
15. WORK ORDER (Place an "X" in the appropriate box.)
17. SELF-HELP (Place an "X" in the appropriate box.)
16. DIRECT SCHEDULED WORK (Place an "X" in the appropriate box.)
18. WORK CLASS 19. PRIORITY 20. ESTIMATED HOURS
COST
21. ESTIMATED FUNDED
COST
22. ESTIMATED TOTAL
BEING/HAS BEEN PROCESSED
24.
A WRITTEN ASSESSMENT IS APPROVED
25. 26.
29. SIGNATURE
14. COORDINATION
OCAMPO.DANILO.T.
1028298613
Digitally signed by OCAMPO.DANILO.T.1028298613 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USAF, cn=OCAMPO.DANILO.T.1028298613 Date: 2016.03.01 11:42:16 -08'00'
1028298613C Rectangle
| 1 16539 - fp.pdf |
| 2 16539 - asb asses.pdf |
| 3 16539 - pb asses.pdf |
| 4 16539 - Diagram.pdf |
| 5 16539 - asb lab.pdf |
| 6 16539 - xrf.pdf |
| 7 16139 - wo.pdf |
Text1: EDDIE N. CAIN, WS-15 Operations Manager