03876Nellis Work Order:
Replace carpeting throughout building 16.
WO Scope of Work:
16Building Number:
6/14/2004Inspection Date:
10492
DGM’s Job Number:
Nellis Air Force Base Asbestos and Lead Based Paint
Project Database
This project was conducted by DGM Environmental.
The information contained in this report pertains only to the specific area defined in the above work order scope of work. Only proper personel should interperet this report to determine whether the information herein can be utilized for future renovation activities within this building.
MACC Attachment 56
Asbestos Sample Results
Description Sample ID Content#
The following table provides an inventory of the suspect materials containing asbestos identified during DGM's inspection of the subject site. The table provides each of the materials unique sample identification number and corresponding laboratory result.
Work Order: 03876 Building: 16
1 Mastic - Beneath Carpet - Yellow
10492 AB1 None Detected-- Hallway - Adj Door
2 Mastic - Beneath Carpet - Yellow
10492 AB2 None Detected-- Office 10 - Adj Door
Appendix A - Asbestos Results, Pg. 1 DGM Project # 10492
Sample Location Diagram
Asbestos Survey Job #104.92 NAFB - Bldg. 16 Appendix B
* Diagram Not Drawn To Scale
NAFB
BUILDING # 16
AB1
AB2
Room 10
Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report
Work Order Scope of Work:
Install LAN lines in south wall of Open Area
Building Number: 16
Inspection Date: 12/20/2011
Nellis Work Order: 18702
Macrotec Job Number: 11910
The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building
Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.
Introduction:
Report Limitations:
9724 Mild Weather Ct., Las Vegas, NV 89148 Phone: (702) 338-8213 Fax: (702) 629-5677
Macrotec Consulting, LLC.
Appendix A - Asbestos Assessment
Macrotec Job #11910 - WO #18702 - Bldg. 16
The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.
1 Sheet Rock, Mud & Tape No Asbestos Detected
AB1 Open Area - Adj. S Door None Detected
AB2 Open Area - SW Corner None Detected
2 Spray Texture on Wall No Asbestos Detected
AB3 Open Area - SW Corner None Detected
AB4 Open Area - S Wall None Detected
AB5 Open Area - Adj. S Door None Detected
3 2X2 Ceiling Tile No Asbestos Detected
AB6 Open Area - Adj. S Door None Detected
Asbestos Survey
Bldg. 16
Macrotec Job #11910
Appendix B - Lead Assessment
Macrotec Job #11910 - WO #18702 - Bldg. 16
The following table lists each of the painted surfaces suspected to contain lead at the subject site. For each painted surface, the sample number, location and laboratory result are listed.
Sample
Painted Surface Description
Sample Location Description
Lab Result (Parts per Million)
L1 Open Area - S Wall 56White Sheet Rock Wall
Lead Paint Survey
Bldg. 16
Macrotec Job #11910
Asbestos & Lead Based Paint Survey
Nellis AFB, Bldg. 16
Macrotec Project # 11910
Appendix C
* Diagram Not Drawn To Scale
Sample Location Diagram
L1
AB1
AB2
AB3
AB4
AB5
AB6
L1
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
804-739-1751 • fax: 804-739-1753
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
11910
Bldg 16
111221K
12/21/2011
12/22/2011
12/22/2011
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB/ #:
1 AB1 / White powder NAD 100%
2 AB2 / White powder NAD 100%
3 AB3 / White powder NAD 100%
4 AB4 / White powder NAD 100%
5 AB5 / White powder NAD 100%
6 AB6 / Gray fibers NAD 10%80% Cellulose
10% Fiberglass
Total Samples/Layers Analyzed: 6
Thursday, December 22, 2011 Page 1 of 1
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112 • 804-739-1751 • fax: 804-739-1753
(EPA METHOD 7420)
LEAD IN PAINT SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
11910
Bldg 16
111221P
12/21/2011
12/22/2011
12/27/2011
B. StoneJOBSITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT
SAMPLE #
SAMPLE
WEIGHT (mg)
LEAD CONCENTRATION
PPM
CLIENT:
CLIENT JOB #:
LEAD CONCENTRATION
(% by Weight)
TOTAL LEAD
(ug)
1 L1 195 0.006 56
Sample weight below Lab SOP guidelines.
10.8
Total Sample(s) Analyzed:
Tuesday, December 27, 2011 Page 1 of 1
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the customer. Sample information was provided by the customer. This report must not be reproduced, except in full,without the written consent of Triangle Environmental Service Center, Inc. The test report related only to the item(s) tested. This analysis was performed by an AHIA accredited laboratory. AIHA/ELLAP ID: 100527, NYELAP/NELAC ID: 11413.
Minimum Reporting Limit: 20 ug. Lead Based Paint contains 0.5% lead by weight per Federal statute. The OSHA Lead in Construction Standard, 29 CFR
1926.62, is invoked if any lead is present in the sample. Lead-free paint is defined as <0.06% by weight (CPSC).
[LEGEND: mg= milligram, ug= microgram, ppm= parts per million]
Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report
Work Order Scope of Work:
Paint the exterior
Building Number: 16
Inspection Date: 5/29/2015
Nellis Work Order: 16686
Macrotec Job Number: 15573
The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building
Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.
Introduction:
Report Limitations:
Dustin R. McAllister
Nevada-OSHA Certified Asbestos Abatement Consultant
License # IPM0961
US EPA Lead Risk Assessor
Certificate # NV-R-16781-2
9724 Mild Weather Ct., Las Vegas, NV 89148 Phone: (702) 338-8213 Fax: (702) 629-5677
Appendix A - Asbestos Assessment
Macrotec Job #15573 - Bldg. 16
No suspect asbestos containing materials were identified during this investigation, based on the specific scope of work for the project. If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.
Asbestos Survey
WO #16686 - Bldg. 16
Macrotec Job #15573
Appendix B - Lead Assessment
Macrotec Job #15573 - Bldg. 16
Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix D lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.
Lead Paint Survey
WO #16686 - Bldg. 16
Macrotec Job #15573
Asbestos and Lead Based Paint Inspection
Nellis AFB—Building 16
Macrotec Project # 15573
Appendix C
Sample Location Diagram
Picture 1—The Exterior of the building
Picture 2—The Exterior of the building
XRF Data Table
Time Duration Component Substrate Side Color Condition Building Room Results Depth PbC PbC Error PbL PbL Error PbK PbK Error
5/27/15 10:57 1.03 Stair Rail Metal A Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.65
5/27/15 10:58 3.11 Wall Brick A Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.5
5/27/15 10:58 3.12 Door Metal A Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.51
5/27/15 10:59 3.11 Doorframe Metal A Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.32
5/27/15 11:01 6 Fence Stucco A Beige Intact 16 Exterior Null 1 < LOD 0.03 < LOD 0.03 1.2 0.6
5/27/15 11:02 4.01 Base Brick A White Intact 16 Exterior Negative 5.49 < LOD 0.06 < LOD 0.06 < LOD 1.2
5/27/15 11:03 1.83 Gutter Brick B Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.45
5/27/15 11:04 7.82 Window Frame Metal B Black Intact 16 Exterior Null 1.23 < LOD 0.03 < LOD 0.03 1.3 0.6
5/27/15 11:05 10.1 Window Frame Metal B Black Intact 16 Exterior Negative 2.22 < LOD 0.03 < LOD 0.03 0.8 0.5
5/27/15 11:05 2.07 Window Frame Metal B Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.97
5/27/15 11:06 1.6 Door Metal B Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.25
5/27/15 11:06 1.04 Door Metal B Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.57
5/27/15 11:06 1.03 Doorframe Metal B Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.11
5/27/15 11:07 4.95 Wall Brick C Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.2
5/27/15 11:08 0.23 Fascia Stucco C Beige Intact 16 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 12.6
5/27/15 11:08 2.42 Fascia Stucco C Beige Intact 16 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 2.4
5/27/15 11:09 1.03 Door Metal D Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.56
5/27/15 11:10 1.03 Doorframe Metal D Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.97
5/27/15 11:11 8.96 Fascia Stucco D Beige Intact 16 Exterior Negative 1.25 < LOD 0.03 < LOD 0.03 1.2 0.5
5/27/15 11:12 3.1 Window Frame Metal D Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.25
5/27/15 11:13 7.12 Window Sill Metal D Black Intact 16 Exterior Negative 2 < LOD 0.03 < LOD 0.03 < LOD 1.05
Nellis Air Force Base Building 16 Macrotec Job #15573 1
| 2004-06-14 Replace carpet B16 |
| 2011-12-20 LAN lines B16 |
| 11910 - FP.pdf |
| 11910 - As Assess.pdf |
| 11910 - Pb Assess.pdf |
| 4 11910 - Diagram.pdf |
| 11910 - As Lab.pdf |
| 111221k |
| CCF12222011_00084 |
| 11910 - Pb Lab.pdf |
| 111221p |
| CCF12272011_00007 |
11910 - wo.pdf
| 2015-05-27 Paint the exterior B16 |
| 1 15573 - fp.pdf |
| 2 15573 - asb asses.pdf |
| 3 15573 - pb asses.pdf |
| 4 15573 - Diagram.pdf |
| 6 15573 - xrf.pdf |
| 7 15573 - wo.pdf |
File details come from the government source that posted it. Updated .