Atch_56_Asbestos_ _LBP_Reports _RKMF_16-0062_Rpr_Courtroom _Bldg_16.pdf

PDF 4 MB Posted

Attached to
Nellis AFB Multiple Award Construction Contract (MACC) Solicitation
Solicitation number
FA4861-16-R-A100
Issued by

About this file

Atch 56_Asbestos LBP Reports RKMF 16-0062 Rpr Courtroom Bldg 16

View the file

Other files

File Type Posted
SYNOPSIS_OF_AWARD.docx DOCX document
Bldg16_CAD.zip ZIP file
AutoCADcombined.dwg DWG drawing
Atch_61__AF_Facility_Metering_Policy.pdf PDF
FA4861-16-R-A100-0006_Updated_Docs_Technical_QnA.pdf PDF
Atch_53_Statement_of_Work _RKMF_16-0062_Rpr_Courtroom _Bldg_16_Revision_2.pdf PDF
Atch_62__Nellis_Creech_AFB_Facility_Metering_Requirements.pdf PDF
Atch_43_Schedule_of_Values_Template_UNLOCKED.xlsx XLSX spreadsheet
Atch_56_Asbestos_ _LBP_Reports _RKMF_16-0062_Rpr_Courtroom _Bldg_16 _Mar_2016.pdf PDF
Atch_60_ETL_07-04_AF_Carpet_Standard.pdf PDF
16RA100_Tech_QA_(Part_3).pdf PDF
Atch_01_MACC_SOW_Revision_1.pdf PDF
Atch_54_Demolition_Plan _RKMF_16-0062_Rpr_Courtroom _Bldg_16.pdf PDF
Atch_48_Teaming_List.doc DOC document
16RA100SignInRosters.pdf PDF
FA4861-16-R-A100-0005_General_QnA.pdf PDF
16RA100_General_Q As_(Part_2).pdf PDF
16RA100_Q A_(Part_1).pdf PDF
Atch_53_Statement_of_Work _RKMF_16-0062_Rpr_Courtroom _Bldg_16_Revision1.pdf PDF
FA4861-16-R-A100-0004_Amend_Demo_SOW_QnA.pdf PDF
Atch_59_Concept_Floor_Plan _RKMF_16-0062_Rpr_Courtroom _Bldg_16.pdf PDF
FA4861-16-R-A100-0003_Amendment.pdf PDF
FA4861-16-R-A100-0002_Amendment.pdf PDF
FA4861-16-R-A100-0001_Amendment.pdf PDF
Atch_41_AF_3064_Progress_Schedule.xfdl XFDL file
Atch_11_AFI_23-204_Material_Management.pdf PDF
Atch_01_MACC_SOW_20160505.pdf PDF
Atch_37_Nuclear_Gauge_Form_1.xlsx XLSX spreadsheet
Atch_18_NAFB_Plan_32-7086_Hazardous_Materials_Management_Plan.pdf PDF
Atch_32_UM17-2_XFMR-Profile_A-size.pdf PDF
Atch_54_Demolition_Plan _RKMF_16-0062_Rpr_Courtroom _Bldg_16.pdf PDF
Atch_51_Sample_Client_Authorization_Letter.doc DOC document
FA486116RA100_Solicitaion.pdf PDF
Atch_43_Schedule_of_Values_Template.xlsx XLSX spreadsheet
Atch_42_Contract_Progress_Report_Template.xfdl XFDL file
Atch_40_AF_3052_Construction_Cost_Estimate_Breakdown.xlsx XLSX spreadsheet
Atch_13_AFI_32-1024_Standard_Facility_Requirements.pdf PDF
Atch_33_UM33-Profile_A-size.pdf PDF
Atch_05_Environmental_Permit_ATP_Guidance.pdf PDF
Atch_21_AFMAN_32-1084_Facility_Requirements.pdf PDF
Atch_23_(CREECH)_UR2_(S).pdf PDF
Atch_58_Bid_Schedule _RKMF_16-0062_Rpr_Courtroom _Bldg_16.doc DOC document
Atch_48_Teaming_List.doc DOC document
Atch_25_3PH__CJE_CREECH_4in-Profile_A-size.pdf PDF
Atch_55_Facility_Photos _RKMF_16-0062_Rpr_Courtroom _Bldg_16.pdf PDF
Atch_24_1PH_CJE-Profile_A-size.pdf PDF
Atch_29_Trench_Sand.pdf PDF
Atch_10_ACCMAN32-7051_hollomanafbsup_1.pdf PDF
Atch_16_AFI_32-7042_Waste_Management.pdf PDF
Atch_02_Nellis_Creech_ID2_Handbook_201108.pdf PDF
Show 40 more

Latest 50 of 81 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

03876Nellis Work Order:

Replace carpeting throughout building 16.

WO Scope of Work:

16Building Number:

6/14/2004Inspection Date:

10492

DGM’s Job Number:

Nellis Air Force Base Asbestos and Lead Based Paint

Project Database

This project was conducted by DGM Environmental.

The information contained in this report pertains only to the specific area defined in the above work order scope of work. Only proper personel should interperet this report to determine whether the information herein can be utilized for future renovation activities within this building.

MACC Attachment 56

Asbestos Sample Results

Description Sample ID Content#

The following table provides an inventory of the suspect materials containing asbestos identified during DGM's inspection of the subject site. The table provides each of the materials unique sample identification number and corresponding laboratory result.

Work Order: 03876 Building: 16

1 Mastic - Beneath Carpet - Yellow

10492 AB1 None Detected-- Hallway - Adj Door

2 Mastic - Beneath Carpet - Yellow

10492 AB2 None Detected-- Office 10 - Adj Door

Appendix A - Asbestos Results, Pg. 1 DGM Project # 10492

Sample Location Diagram

Asbestos Survey Job #104.92 NAFB - Bldg. 16 Appendix B

* Diagram Not Drawn To Scale

NAFB

BUILDING # 16

AB1

AB2

Room 10

Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report

Work Order Scope of Work:

Install LAN lines in south wall of Open Area

Building Number: 16

Inspection Date: 12/20/2011

Nellis Work Order: 18702

Macrotec Job Number: 11910

The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building

Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.

Introduction:

Report Limitations:

9724 Mild Weather Ct., Las Vegas, NV 89148 Phone: (702) 338-8213 Fax: (702) 629-5677

Macrotec Consulting, LLC.

Appendix A - Asbestos Assessment

Macrotec Job #11910 - WO #18702 - Bldg. 16

The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.

1 Sheet Rock, Mud & Tape No Asbestos Detected

AB1 Open Area - Adj. S Door None Detected

AB2 Open Area - SW Corner None Detected

2 Spray Texture on Wall No Asbestos Detected

AB3 Open Area - SW Corner None Detected

AB4 Open Area - S Wall None Detected

AB5 Open Area - Adj. S Door None Detected

3 2X2 Ceiling Tile No Asbestos Detected

AB6 Open Area - Adj. S Door None Detected

Asbestos Survey

Bldg. 16

Macrotec Job #11910

Appendix B - Lead Assessment

Macrotec Job #11910 - WO #18702 - Bldg. 16

The following table lists each of the painted surfaces suspected to contain lead at the subject site. For each painted surface, the sample number, location and laboratory result are listed.

Sample

Painted Surface Description

Sample Location Description

Lab Result (Parts per Million)

L1 Open Area - S Wall 56White Sheet Rock Wall

Lead Paint Survey

Bldg. 16

Macrotec Job #11910

Asbestos & Lead Based Paint Survey

Nellis AFB, Bldg. 16

Macrotec Project # 11910

Appendix C

* Diagram Not Drawn To Scale

Sample Location Diagram

L1

AB1

AB2

AB3

AB4

AB5

AB6

L1

Macrotec Consulting

TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.

13509 East Boundary Road, Suite B, Midlothian, VA 23112

804-739-1751 • fax: 804-739-1753

BULK ASBESTOS SAMPLE ANALYSIS SUMMARY

9724 Mild Weather Ct.

Las Vegas, NV 89148

11910

Bldg 16

111221K

12/21/2011

12/22/2011

12/22/2011

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB/ #:

1 AB1 / White powder NAD 100%

2 AB2 / White powder NAD 100%

3 AB3 / White powder NAD 100%

4 AB4 / White powder NAD 100%

5 AB5 / White powder NAD 100%

6 AB6 / Gray fibers NAD 10%80% Cellulose

10% Fiberglass

Total Samples/Layers Analyzed: 6

Thursday, December 22, 2011 Page 1 of 1

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993

(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or

Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

Feng Jiang, MS Senior Geologist, Laboratory Director

Yuedong Fang, Senior Geologist

Macrotec Consulting

TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.

13509 East Boundary Road, Suite B, Midlothian, VA 23112 • 804-739-1751 • fax: 804-739-1753

(EPA METHOD 7420)

LEAD IN PAINT SAMPLE ANALYSIS SUMMARY

9724 Mild Weather Ct.

Las Vegas, NV 89148

11910

Bldg 16

111221P

12/21/2011

12/22/2011

12/27/2011

B. StoneJOBSITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT

SAMPLE #

SAMPLE

WEIGHT (mg)

LEAD CONCENTRATION

PPM

CLIENT:

CLIENT JOB #:

LEAD CONCENTRATION

(% by Weight)

TOTAL LEAD

(ug)

1 L1 195 0.006 56

Sample weight below Lab SOP guidelines.

10.8

Total Sample(s) Analyzed:

Tuesday, December 27, 2011 Page 1 of 1

Reviewed By Authorized Signatory:

Feng Jiang, MS Senior Geologist, Laboratory Director

Yuedong Fang, Senior Geologist

The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the customer. Sample information was provided by the customer. This report must not be reproduced, except in full,without the written consent of Triangle Environmental Service Center, Inc. The test report related only to the item(s) tested. This analysis was performed by an AHIA accredited laboratory. AIHA/ELLAP ID: 100527, NYELAP/NELAC ID: 11413.

Minimum Reporting Limit: 20 ug. Lead Based Paint contains 0.5% lead by weight per Federal statute. The OSHA Lead in Construction Standard, 29 CFR

1926.62, is invoked if any lead is present in the sample. Lead-free paint is defined as <0.06% by weight (CPSC).

[LEGEND: mg= milligram, ug= microgram, ppm= parts per million]

Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report

Work Order Scope of Work:

Paint the exterior

Building Number: 16

Inspection Date: 5/29/2015

Nellis Work Order: 16686

Macrotec Job Number: 15573

The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building

Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.

Introduction:

Report Limitations:

Dustin R. McAllister

Nevada-OSHA Certified Asbestos Abatement Consultant

License # IPM0961

US EPA Lead Risk Assessor

Certificate # NV-R-16781-2

9724 Mild Weather Ct., Las Vegas, NV 89148 Phone: (702) 338-8213 Fax: (702) 629-5677

Appendix A - Asbestos Assessment

Macrotec Job #15573 - Bldg. 16

No suspect asbestos containing materials were identified during this investigation, based on the specific scope of work for the project. If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.

Asbestos Survey

WO #16686 - Bldg. 16

Macrotec Job #15573

Appendix B - Lead Assessment

Macrotec Job #15573 - Bldg. 16

Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix D lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.

Lead Paint Survey

WO #16686 - Bldg. 16

Macrotec Job #15573

Asbestos and Lead Based Paint Inspection

Nellis AFB—Building 16

Macrotec Project # 15573

Appendix C

Sample Location Diagram

Picture 1—The Exterior of the building

Picture 2—The Exterior of the building

XRF Data Table

Time Duration Component Substrate Side Color Condition Building Room Results Depth PbC PbC Error PbL PbL Error PbK PbK Error

5/27/15 10:57 1.03 Stair Rail Metal A Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.65

5/27/15 10:58 3.11 Wall Brick A Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.5

5/27/15 10:58 3.12 Door Metal A Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.51

5/27/15 10:59 3.11 Doorframe Metal A Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.32

5/27/15 11:01 6 Fence Stucco A Beige Intact 16 Exterior Null 1 < LOD 0.03 < LOD 0.03 1.2 0.6

5/27/15 11:02 4.01 Base Brick A White Intact 16 Exterior Negative 5.49 < LOD 0.06 < LOD 0.06 < LOD 1.2

5/27/15 11:03 1.83 Gutter Brick B Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.45

5/27/15 11:04 7.82 Window Frame Metal B Black Intact 16 Exterior Null 1.23 < LOD 0.03 < LOD 0.03 1.3 0.6

5/27/15 11:05 10.1 Window Frame Metal B Black Intact 16 Exterior Negative 2.22 < LOD 0.03 < LOD 0.03 0.8 0.5

5/27/15 11:05 2.07 Window Frame Metal B Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.97

5/27/15 11:06 1.6 Door Metal B Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.25

5/27/15 11:06 1.04 Door Metal B Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.57

5/27/15 11:06 1.03 Doorframe Metal B Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.11

5/27/15 11:07 4.95 Wall Brick C Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.2

5/27/15 11:08 0.23 Fascia Stucco C Beige Intact 16 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 12.6

5/27/15 11:08 2.42 Fascia Stucco C Beige Intact 16 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 2.4

5/27/15 11:09 1.03 Door Metal D Brown Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.56

5/27/15 11:10 1.03 Doorframe Metal D Gray Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.97

5/27/15 11:11 8.96 Fascia Stucco D Beige Intact 16 Exterior Negative 1.25 < LOD 0.03 < LOD 0.03 1.2 0.5

5/27/15 11:12 3.1 Window Frame Metal D Black Intact 16 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.25

5/27/15 11:13 7.12 Window Sill Metal D Black Intact 16 Exterior Negative 2 < LOD 0.03 < LOD 0.03 < LOD 1.05

Nellis Air Force Base Building 16 Macrotec Job #15573 1

2004-06-14 Replace carpet B16
2011-12-20 LAN lines B16
11910 - FP.pdf
11910 - As Assess.pdf
11910 - Pb Assess.pdf
4 11910 - Diagram.pdf
11910 - As Lab.pdf
111221k
CCF12222011_00084
11910 - Pb Lab.pdf
111221p
CCF12272011_00007

11910 - wo.pdf

2015-05-27 Paint the exterior B16
1 15573 - fp.pdf
2 15573 - asb asses.pdf
3 15573 - pb asses.pdf
4 15573 - Diagram.pdf
6 15573 - xrf.pdf
7 15573 - wo.pdf

File details come from the government source that posted it. Updated .