Atch_11_MACC_Demonstration_Project_SOW_KWRD090122A.pdf

PDF 666 KB Posted

Attached to
Holloman AFB MACC Federal contract opportunity
Solicitation number
FA4801-11-R-0003
Issued by
Department of the Air Force Air Combat Command

About this file

MACC Demonstration Project SOW

View the file

Other files for this federal contract opportunity

Other files attached to Holloman AFB MACC, newest first.
File Type Posted
AF_From_3064_Progress_Schedule_excel_template_26_Oct_2011.xls XLS spreadsheet
AF66.xlsx XLSX spreadsheet
01_Cover_Sheet.dwg DWG drawing
Geotech_Study_-_Fire_Stations.pdf PDF
Summary_of_Amendments_to_MACC.xlsx XLSX spreadsheet
MACC_QA_-_Round_2_Final_as_of_31_Oct_2013.xlsx XLSX spreadsheet
Consent_Letter_Past_Performance_29_Oct_13.pdf PDF
Atch_2_MACC_Statement_of_Work_17_Oct_2013.docx DOCX document
Atch_2_MACC_Statement_of_Work_10_Oct_2013.pdf PDF
Attach_2_MACC_Statement_of_Work_(SOW).pdf PDF
MACC_solicitation_amendment_6_dated_10_Oct_2013.pdf PDF
Historical_workload.pptx PPTX presentation
MACC_QA_Round_1_FINAL.xlsx XLSX spreadsheet
Atch_25_MACC_SITE_MAP.jpg JPG image
Atch_24__AF_3052.xlsx XLSX spreadsheet
Atch_8-1_Consent_Form.pdf PDF
Attachment_23_Financial_Information_Request.pdf PDF
MACC_Amend_1.pdf PDF
MACC_SITE_VISIT_List_of_Attendees_5_Sept_2013.docx DOCX document
A_MACC_Solicitation_19_Aug_2013.pdf PDF
Atch_16_DD_1354_Quick_Notes.pdf PDF
Atch_13_Base_Access.pdf PDF
Atch_22_HAFB_Chemical_Reuse_Program.pdf PDF
Atch_9_Visitor_Access_Request_Form_and_Consent_Form.doc DOC document
Atch_1_Holloman_AFB_Local_Procedures_19_Aug_2013.pdf PDF
Atch_2_MACC_Statement_of_Work_19_Aug_2013.pdf PDF
A_MACC_Solicitation_19_Aug_2013.pdf PDF
Atch_17_HAFB_Recycling_Guide.pdf PDF
Atch_6_Wage_Determination_NM130005_01-04-2013_Residential.pdf PDF
Atch_4_Wage_Determination_NM30008_01-04-2013_Heavy.pdf PDF
Atch_5_Wage_Determination_NM130050_01-04-2013_Highway.pdf PDF
Atch_8-3_Client_Authorization_Letter.pdf PDF
Atch_20_HAFB_Storm_Water_Pollution_Prevention_Plan.pdf PDF
Atch_7_AF_From_66_Sample.pdf PDF
Atch_3_Wage_Determination_NM130032_01-04-2013_Building.pdf PDF
Atch_15_Form_1354.pdf PDF
Atch_10_2012_Holloman_AFB_Design_Compatibility_Standards.pdf PDF
Atch_19_HAFB_Municipal_Solid_Waste_Mgmt_Plan.pdf PDF
Atch_21_HAFB_Integrated_Natural_Resource_Mgmt_Plan.pdf PDF
Atch_12_AF_3064_--_Construction_Progress_Schedule.pdf PDF
Atch_8-2_Past_Performance_Info_Sheet.pdf PDF
Atch_8-4_Sample_Past_Experience_List.pdf PDF
Atch_14_HAFB_Standard_Design.pdf PDF
Atch_18_HAFB_Lead_Based_Paint_Mgmt_Plan.pdf PDF
Show all 44

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA4801-11-R-0003

Atch 10

DEMONSTRATION PROJECT TASK ORDER

STATEMENT OF WORK

REQUEST FOR PROPOSAL

19 August 2013

CONSTRUCT FIRE TRAINING CLASSROOM, BLDG. 17905

WORK ORDER #A00001

PROJECT #KWRD 09-0122A

PROGRAM MANAGEMENT ELEMENT

49TH CIVIL ENGINEERING SQUADRON

49TH WING

HOLLOMAN AIR FORCE BASE, NEW MEXICO 88330

PHONE (505) 475-5832

Project Manager: U S Air Force

Notes:

a. Holloman Air Force Base (HAFB) is located approximately six (6) miles south of Alamogordo on Highway U.S-70. The specific project location is in the Fire Training Area located off of Saber Road in the HAFB North Area. Locations are also indicated on drawings accompanying this statement of work.

b. Normal (standard) work hours are 0700 to 1600.

1. STATEMENT OF WORK:

The 49 th

Wing, Holloman AFB, NM, requests a proposal for work to be accomplished at the Fire Training Classroom, Bldg. 17905. The work to be accomplished includes but is NOT LIMITED to the following: All plant, labor, equipment, materials and incidentals shall be furnished by the contractor. All work must be in accordance with applicable codes and construction practices. All work as a minimum must MEET acceptable standards of the applicable building trades.

Contractor shall thoroughly review the project for constructability and advice and correct, as well as recommend improvements to the design prior to Task Order negotiation. Provide standard foundations; slabs on grade; pre-engineered building construction; metal exterior walls; exterior windows; exterior doors; roof coverings;

interior partitions; interior doors; interior specialties; interior wall finishes; interior floor finishes; interior ceiling finishes; plumbing fixtures; domestic water distribution;

sanitary waste systems; heat pumps; heat distribution systems; HVAC controls and instrumentation; HVAC systems testing, adjusting and balancing; electrical service and distribution; lighting and branch wiring; communication and fire detection systems; site clearing; site earthwork; pedestrian paving; site development; site water supply and distribution systems; site sanitary sewer systems; site electrical distribution; site lighting systems; and site communication systems. Document any assumptions made. This project is for evaluation purposes only and under no circumstances is this to be considered a bonafide contract.

2. PURPOSE OF THE DOCUMENT:

This SOW serves as a tool for recording customer requirements. The SOW is the written document that enables the technical inspector and contracting officer to ensure that customer requirements are met and is the basis for evaluating the project design before construction begins. The overall objective is to establish a plan of action for defining and achieving desired results and goals.

3. REQUIREMENTS:

The contractor shall accomplish the following:

Site Clearing

Clear building site.

Site Earthwork

Accomplish site earthwork for :

Building

Stoops

Sidewalk(s)

Water supply system distribution (assume water line 50 feet from building)

Sanitary sewer system (assume sewer line 50 feet from building)

Primary and secondary electrical distribution (assume primary electrical line 50 feet from building)

Communications system

Site lighting system

Site Underground Water Supply Systems

Install a water line.

Site Underground Sanitary Sewer Systems

Install a sanitary sewer line.

Site Underground Primary Electrical Distribution System

Install cable.

Install conduit and concrete encasement for ductbank.

Site Underground Secondary Electrical Distribution System

Install a transformer.

Install conduit and conductors.

Site Underground Communication Systems

Install 2 each 4” PVC conduit. Run from mechanical room to 10’ outside building foot print.

Pedestrian Paving

Fabricate a standard 4’ wide concrete sidewalk as required from training area parking lot to main entrance.

Presume a 4” gravel base and 4” concrete.

Site Lighting Systems

Install area lighting as required to achieve adequate illumination levels for activities during non-daylight hours on sidewalk(s).

Include underground electric conductors as required.

Standard Foundations

Integrate a continuous footing wall foundation and spread footings where required

Size for superstructure load and sandy soil conditions.

Slabs on Grade

Construct a 40’ x 50’ reinforced concrete slab on grade for an approximate

SF building footprint.

Design for superstructure load and soil conditions.

Construct 6’ x 6’ x 4” concrete stoops at each exterior door.

Fabricate 4” thick mechanical equipment pad(s) for exterior HVAC units and transformer with a 4” gravel base.

Building Construction

Utilize a 40 foot by 50 foot by 12 foot eave height pre-engineered building.

Include gutters and downspouts.

Insulate roof construction with vinyl back insulation.

Composite roof system net insulation to be R-30.

Exterior Walls

Standard metal siding.

Eave height to be approximately 12’ above finished floor.

Color to be Sahara Tan with Coco Brown trim.

Furr out interior face of exterior walls with 3 5/8” steel studs (25 gauge).

Insulate exterior walls with R-11 batt insulation.

Install, tape, finish, texture and paint a 5/8” gypsum board interior skin.

Exterior Windows

Install bronze anodized aluminum frame double hung type windows (double glazed) as required by the building’s design and Force Protection standards.

Exterior Doors

Install a 3’0” X 7’0” bronze anodized aluminum and tinted glass door at the main entrance.

Install a 3’0” X 7’0” hollow metal door at the service entrance and at mechanical room

Interior Partitions

Erect steel stud (2 X 4) partitions as required by the building’s plan.

Finish interior partitions with 5/8” gypsum board (taped, finished and textured).

Include batt insulation for any sound-rated partitions.

Interior Doors

Install 3’0” X 7’0” solid wood core, 5-ply, birch face, clear finish doors as required by the building’s interior plan.

Include necessary hardware such as frames, hinges, locksets, doorstops and closers.

Interior Specialties

Install standard toilet accessories in both restrooms.

Install grab bars, soap dispensers, toilet tissue dispensers, and towel dispensers, etc.

Install painted metal floor mounted toilet partitions.

Situate prefinished vanity base in each bathroom. (2 Total)

Install wall mirrors in both restrooms.

Install 2 each fire extinguisher cabinets.

Situate prefinished base and wall cabinets in break area.

Include solid plastic countertop with backsplash.

Interior Wall Finishes Prime and paint (2 coats) interior partitions.

Interior Floor Finishes

Finish floors in all areas (restrooms and mechanical room) with 12” X 12” vinyl composition tile (1/8” thick) and 4” vinyl cove base.

Finish restroom floors with 2” X 2” thin set ceramic tile.

Include thin set ceramic tile cove base.

Mechanical room will be exposed concrete.

Interior Ceiling Finishes

Install a 2’ X 2’ suspended acoustic reveal edge tile ceiling in all areas (except store room and mechanical room).

Install a 5/8” gypsum wallboard (taped, finished, textured and painted) ceiling in store room, and mechanical room.

Plumbing Fixtures

Situate floor mounted flush valve water closets in both restrooms (3 total).

Situate one in men’s room.

Situate two in women’s room.

Situate 1 each wall-hung, vitreous china urinal in men’s restroom.

Situate 1 each vanity top, single bowl lavatory (cultured marble, 19” X 17”) in both restrooms (2 total).

Situate 1 each stainless steel single bowl sink in break area base cabinet.

Situate 1 each wall mounted electric water cooler in breakroom area.

Domestic Water Distribution

Install copper pipe and fittings as required by plumbing fixtures.

Install valves as required by plumbing fixtures.

Situate 1 each 40-gallon water heater.

Sanitary Waste Systems

Install PVC waste and vent pipe and fittings as required by plumbing fixtures.

Heat Pumps

Furnish building with a split system.

System shall have a reciprocating compressor.

System shall be air cooled and direct expansion.

Systems to be designed using 105-degree condensing temperatures.

Furnish auxiliary heat for low ambient conditions.

Installation clearances will be to manufacturer’s specifications.

Heat Distribution Systems

Position exhaust ventilation systems in both restrooms.

Install galvanized steel ductwork sized for .05” static pressure per 100 feet of duct .

Install supply diffusers and return grilles as required for efficient air distribution.

Install galvanized steel ductwork.

Ducting sized for .1” static pressure per 100 feet of supply air duct.

Ducting sized for .05” static pressure per 100 feet of return air duct.

Insulate ductwork.

System to be designed using fresh air make-up requirements.

Install fire/smoke dampers as required.

HVAC Controls and Instrumentation

Install DDC controls as required by HVAC system.

HVAC Systems Testing, Adjusting and Balancing

Test and balance HVAC system.

Electrical Service and Distribution

Install 1 each panel board.

Lighting and Branch Wiring

Receptacles:

Install 20 amp receptacles in accordance with the building’s plan.

Include conduit and wiring.

Lighting

Install 2’ X 4’ lay-in fluorescent (T-8) light fixtures as required to achieve general office lighting levels in all areas with suspended ceilings.

Install 2’ X 4’ surface mounted fluorescent (T-8) light fixtures in mechanical and store room.

Install exterior lighting at each exterior door.

Provide switching for lighting.

Include conduit and wiring.

Fire Alarm Systems

Furnish building with a fire alarm/detection system. Alarm activation will be transmitted by Monaco BTXF narrowband radio to Fire Station.

Include duct smoke detector(s) as required.

Fire alarm panel shall be Notifier® addressable (or equal).

Fire alarm system shall be tested prior to acceptance by government.

Communication Systems

Situate telephone outlets as required.

Install 4’ X 4’ 5/8” plywood telephone backboard in mechanical room.

Install 2 each cat 5, 24-gauge communication cable from telephone backboard to each telephone outlet location.

Situate computer outlets boxes as required (at least one per office/reception wall).

Install 4’ X 4’ 5/8” plywood network cabling backboard in mechanical room.

Run conduit from above the ceiling to each computer outlet box with blank cover for box and pull string.

Miscellaneous Presume an 8’ floor to ceiling height.

Presume an approximate 2000 SF building footprint.

Comply with ADA requirements for interior and exterior of building. Adjust room sizes as required to meet ADA requirements.

Drawings to be provided by contractor:

a. Cover sheet

b. Existing site plan

c. Final site plan

d. Grading plan

e. Underground utility plan

f. Floor plan

g. Structural plan and details

h. Elevations

i. Finish schedule

j. Wall and roof sections

k. Door schedule

l. Mechanical plans and details

m. Plumbing riser diagram

n. Power plan and lighting plan

o. Fire detection plan

p. ADA and Life Safety plan

Draft Sketch of Sample Project Floor Plan (Not To Scale)